SIO Argo Site:
Pump Diagnostics Page   



Serial= 3312 WMO= 3902523

Return

←PreviousNext→

Cycle 7 GMT 31/ 1/2025 5:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 30 15.20 458 209 0.21 / 24.05 2 3
2 3 1024.32 1 15.28 1694 26 0.23 / 24.08 2 5
3 7 2003.32 74 14.81 2822 3093 3.33 / 27.17 2 6
4 13 558.80 18 15.18 1043 285 3.61 / 27.45 2 10
5 13 42.80 18 15.29 353 97 3.71 / 27.55 2 16
6 8 -0.08 165 15.25 295 742 4.45 / 28.29 2 14
Average= 3.54
(KJ/cycle)

Cycle 6 GMT 21/ 1/2025 8:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 28 15.20 450 192 0.19 / 19.56 2 3
2 10 1044.08 2 15.23 1703 52 0.24 / 19.61 2 4
3 3 1017.80 1 15.29 1659 25 0.27 / 19.63 2 5
4 7 2011.08 74 14.81 2832 3104 3.37 / 22.74 2 4
5 13 522.60 18 15.19 993 272 3.64 / 23.01 2 11
6 13 29.60 18 15.30 337 93 3.74 / 23.10 2 12
7 8 0.12 165 15.26 293 738 4.47 / 23.84 2 19
Average= 3.41
(KJ/cycle)

Cycle 5 GMT 11/ 1/2025 11:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 31 15.25 450 213 0.21 / 15.18 2 5
2 3 947.88 -1 15.62 0 0 0.00 / 15.18 2 5
3 3 970.40 -1 15.65 0 0 0.00 / 15.18 2 5
4 7 2011.24 74 14.81 2823 3094 3.31 / 18.27 2 6
5 13 506.00 18 15.19 965 264 3.57 / 18.53 2 9
6 13 51.00 18 15.29 365 100 3.67 / 18.63 2 14
7 8 -0.04 165 15.25 291 732 4.40 / 19.37 2 16
Average= 3.23
(KJ/cycle)

Cycle 4 GMT 1/ 1/2025 14:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 29 15.24 444 196 0.20 / 11.55 2 4
2 3 1023.88 1 15.30 1680 26 0.22 / 11.57 2 7
3 7 1526.04 75 15.00 2242 2522 2.74 / 14.09 2 9
4 13 179.24 18 15.31 538 148 2.89 / 14.24 2 13
5 8 0.12 165 15.29 286 722 3.61 / 14.96 2 23
Average= 2.99
(KJ/cycle)

Cycle 3 GMT 31/12/2024 14:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 26 15.24 436 173 0.17 / 7.91 2 3
2 10 1018.44 3 15.23 1679 77 0.25 / 7.99 2 4
3 3 1034.88 1 15.30 1694 26 0.28 / 8.01 2 6
4 7 1507.32 74 15.01 2230 2477 2.75 / 10.49 2 7
5 13 168.12 18 15.32 517 143 2.89 / 10.63 2 10
6 8 0.20 165 15.29 284 716 3.61 / 11.35 2 15
Average= 2.84
(KJ/cycle)

Cycle 2 GMT 30/12/2024 15:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 33 15.29 434 219 0.22 / 4.40 2 7
2 3 828.92 -3 15.63 0 0 0.00 / 4.40 2 7
3 3 898.56 -2 15.66 0 0 0.00 / 4.40 2 7
4 7 1512.68 74 15.00 2228 2473 2.69 / 6.87 2 6
5 13 168.84 18 15.33 518 143 2.84 / 7.02 2 14
6 8 0.04 165 15.31 285 720 3.55 / 7.74 2 17
Average= 2.58
(KJ/cycle)

Cycle 1 GMT 29/12/2024 15:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 28 15.45 408 177 0.18 / 1.69 2 3
2 7 1004.08 74 15.18 1577 1771 1.95 / 3.46 2 8
3 8 -0.08 165 15.35 284 719 2.67 / 4.18 2 20
Average= 2.09
(KJ/cycle)

Cycle 0 GMT 29/12/2024 5: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 82.88 28 15.62 347 152 0.15 / 0.15 3 3
2 7 98.16 75 15.58 385 450 0.60 / 0.60 3 5
3 8 0.36 240 15.54 245 914 1.52 / 1.52 3 18
Average= 1.52
(KJ/cycle)