SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.08 | 29 | 15.24 | 431 | 190 | 0.19 / 106.62 | 2 | 5 |
2 | 7 | 2004.84 | 38 | 14.93 | 2820 | 1600 | 1.79 / 108.22 | 2 | 12 |
3 | 13 | 1329.32 | 18 | 15.06 | 2018 | 547 | 2.34 / 108.77 | 2 | 17 |
4 | 13 | 879.56 | 18 | 15.14 | 1463 | 399 | 2.74 / 109.17 | 2 | 18 |
5 | 13 | 185.00 | 18 | 15.31 | 555 | 153 | 2.89 / 109.32 | 2 | 13 |
6 | 13 | 32.52 | 18 | 15.34 | 333 | 92 | 2.98 / 109.41 | 2 | 9 |
7 | 13 | 28.76 | 18 | 15.31 | 321 | 88 | 3.07 / 109.50 | 2 | 12 |
8 | 8 | 0.04 | 165 | 15.27 | 272 | 685 | 3.75 / 110.19 | 2 | 14 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.68 | 29 | 15.24 | 435 | 192 | 0.19 / 102.87 | 2 | 3 |
2 | 7 | 2005.00 | 38 | 14.94 | 2824 | 1603 | 1.80 / 104.47 | 2 | 12 |
3 | 13 | 1332.36 | 18 | 15.07 | 2012 | 546 | 2.34 / 105.02 | 2 | 16 |
4 | 13 | 776.56 | 18 | 15.19 | 1315 | 360 | 2.70 / 105.38 | 2 | 17 |
5 | 13 | 261.20 | 18 | 15.30 | 655 | 180 | 2.88 / 105.56 | 2 | 15 |
6 | 13 | 34.56 | 18 | 15.34 | 336 | 93 | 2.97 / 105.65 | 2 | 6 |
7 | 13 | 31.44 | 18 | 15.32 | 330 | 91 | 3.06 / 105.74 | 2 | 9 |
8 | 8 | 0.04 | 165 | 15.28 | 274 | 691 | 3.76 / 106.43 | 2 | 24 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.48 | 29 | 15.24 | 431 | 190 | 0.19 / 99.14 | 2 | 8 |
2 | 7 | 2008.80 | 38 | 14.93 | 2823 | 1602 | 1.79 / 100.74 | 2 | 15 |
3 | 13 | 1346.96 | 18 | 15.06 | 2030 | 550 | 2.34 / 101.29 | 2 | 17 |
4 | 13 | 742.80 | 18 | 15.19 | 1267 | 346 | 2.69 / 101.63 | 2 | 18 |
5 | 13 | 242.68 | 18 | 15.31 | 610 | 168 | 2.86 / 101.80 | 2 | 15 |
6 | 13 | 38.48 | 18 | 15.34 | 334 | 92 | 2.95 / 101.89 | 2 | 8 |
7 | 13 | 35.00 | 18 | 15.32 | 334 | 92 | 3.04 / 101.99 | 2 | 13 |
8 | 8 | -0.16 | 165 | 15.28 | 274 | 691 | 3.73 / 102.68 | 2 | 11 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 29 | 15.24 | 408 | 180 | 0.18 / 95.47 | 2 | 9 |
2 | 7 | 2005.48 | 38 | 14.94 | 2822 | 1602 | 1.78 / 97.07 | 2 | 16 |
3 | 13 | 1255.20 | 18 | 15.08 | 1914 | 520 | 2.30 / 97.59 | 2 | 17 |
4 | 13 | 733.64 | 18 | 15.19 | 1268 | 347 | 2.65 / 97.94 | 2 | 18 |
5 | 13 | 152.60 | 18 | 15.31 | 508 | 140 | 2.79 / 98.08 | 2 | 14 |
6 | 13 | 28.40 | 18 | 15.34 | 322 | 89 | 2.88 / 98.17 | 2 | 15 |
7 | 13 | 24.76 | 18 | 15.33 | 317 | 87 | 2.97 / 98.25 | 2 | 4 |
8 | 8 | 0.08 | 165 | 15.29 | 274 | 691 | 3.66 / 98.95 | 2 | 17 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.08 | 29 | 15.26 | 428 | 189 | 0.19 / 91.69 | 2 | 8 |
2 | 7 | 2005.88 | 38 | 14.96 | 2820 | 1603 | 1.79 / 93.30 | 2 | 13 |
3 | 13 | 1383.72 | 18 | 15.07 | 2089 | 567 | 2.36 / 93.86 | 2 | 17 |
4 | 13 | 824.12 | 18 | 15.18 | 1388 | 379 | 2.74 / 94.24 | 2 | 18 |
5 | 13 | 218.12 | 18 | 15.33 | 597 | 165 | 2.90 / 94.41 | 2 | 17 |
6 | 13 | 40.20 | 18 | 15.36 | 344 | 95 | 3.00 / 94.50 | 2 | 20 |
7 | 13 | 36.76 | 18 | 15.34 | 339 | 94 | 3.09 / 94.60 | 2 | 19 |
8 | 8 | 0.20 | 165 | 15.30 | 275 | 694 | 3.79 / 95.29 | 2 | 8 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 29 | 15.25 | 417 | 184 | 0.18 / 87.90 | 2 | 3 |
2 | 7 | 2007.92 | 38 | 14.95 | 2824 | 1604 | 1.79 / 89.51 | 2 | 12 |
3 | 13 | 1422.52 | 18 | 15.06 | 2129 | 577 | 2.37 / 90.08 | 2 | 16 |
4 | 13 | 868.40 | 18 | 15.17 | 1446 | 395 | 2.76 / 90.48 | 2 | 18 |
5 | 13 | 180.48 | 18 | 15.33 | 549 | 151 | 2.91 / 90.63 | 2 | 7 |
6 | 13 | 36.76 | 18 | 15.35 | 341 | 94 | 3.01 / 90.73 | 2 | 10 |
7 | 13 | 32.20 | 18 | 15.34 | 332 | 92 | 3.10 / 90.82 | 2 | 9 |
8 | 8 | 0.04 | 165 | 15.29 | 272 | 686 | 3.78 / 91.50 | 2 | 16 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.60 | 29 | 15.25 | 434 | 192 | 0.19 / 84.22 | 2 | 3 |
2 | 7 | 2005.72 | 38 | 14.95 | 2821 | 1603 | 1.79 / 85.82 | 2 | 13 |
3 | 13 | 1300.00 | 18 | 15.09 | 1977 | 537 | 2.33 / 86.36 | 2 | 16 |
4 | 13 | 725.12 | 18 | 15.21 | 1248 | 342 | 2.67 / 86.70 | 2 | 18 |
5 | 13 | 244.04 | 18 | 15.32 | 609 | 168 | 2.84 / 86.87 | 2 | 24 |
6 | 13 | 44.88 | 18 | 15.34 | 328 | 91 | 2.93 / 86.96 | 2 | 7 |
7 | 13 | 39.84 | 18 | 15.34 | 315 | 87 | 3.02 / 87.04 | 2 | 8 |
8 | 8 | 0.04 | 165 | 15.29 | 268 | 676 | 3.69 / 87.72 | 2 | 23 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 29 | 15.25 | 410 | 181 | 0.18 / 80.46 | 2 | 7 |
2 | 7 | 2010.16 | 38 | 14.96 | 2821 | 1604 | 1.79 / 82.07 | 2 | 14 |
3 | 13 | 1328.40 | 18 | 15.10 | 2006 | 545 | 2.33 / 82.61 | 2 | 17 |
4 | 13 | 791.76 | 18 | 15.19 | 1345 | 368 | 2.70 / 82.98 | 2 | 18 |
5 | 13 | 238.16 | 18 | 15.32 | 626 | 173 | 2.87 / 83.15 | 2 | 19 |
6 | 13 | 37.28 | 18 | 15.35 | 336 | 93 | 2.96 / 83.24 | 2 | 14 |
7 | 13 | 28.44 | 18 | 15.34 | 321 | 89 | 3.05 / 83.33 | 2 | 8 |
8 | 8 | 0.04 | 165 | 15.29 | 274 | 691 | 3.74 / 84.02 | 2 | 8 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.88 | 29 | 15.26 | 407 | 180 | 0.18 / 76.75 | 2 | 3 |
2 | 7 | 2006.00 | 38 | 14.96 | 2821 | 1604 | 1.78 / 78.35 | 2 | 13 |
3 | 13 | 1222.16 | 18 | 15.12 | 1886 | 513 | 2.30 / 78.87 | 2 | 17 |
4 | 13 | 801.24 | 18 | 15.19 | 1359 | 372 | 2.67 / 79.24 | 2 | 18 |
5 | 13 | 192.28 | 18 | 15.33 | 563 | 155 | 2.82 / 79.39 | 2 | 17 |
6 | 13 | 42.64 | 18 | 15.36 | 350 | 97 | 2.92 / 79.49 | 2 | 23 |
7 | 13 | 39.84 | 18 | 15.34 | 343 | 95 | 3.02 / 79.58 | 2 | 23 |
8 | 8 | 0.08 | 165 | 15.30 | 276 | 697 | 3.71 / 80.28 | 2 | 16 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.56 | 29 | 15.26 | 431 | 191 | 0.19 / 72.98 | 2 | 3 |
2 | 7 | 2004.92 | 38 | 14.97 | 2824 | 1606 | 1.80 / 74.58 | 2 | 13 |
3 | 13 | 1362.44 | 18 | 15.09 | 2050 | 557 | 2.35 / 75.14 | 2 | 17 |
4 | 13 | 755.08 | 18 | 15.20 | 1301 | 356 | 2.71 / 75.49 | 2 | 18 |
5 | 13 | 287.08 | 18 | 15.31 | 696 | 192 | 2.90 / 75.69 | 2 | 17 |
6 | 13 | 46.64 | 18 | 15.37 | 354 | 98 | 3.00 / 75.78 | 2 | 10 |
7 | 13 | 36.24 | 18 | 15.35 | 335 | 93 | 3.09 / 75.88 | 2 | 18 |
8 | 8 | -0.04 | 165 | 15.30 | 274 | 692 | 3.78 / 76.57 | 2 | 15 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 29 | 15.26 | 412 | 182 | 0.18 / 69.26 | 2 | 4 |
2 | 7 | 2004.28 | 38 | 14.96 | 2823 | 1605 | 1.79 / 70.87 | 2 | 13 |
3 | 13 | 1353.80 | 18 | 15.09 | 2036 | 553 | 2.34 / 71.42 | 2 | 16 |
4 | 13 | 718.72 | 18 | 15.22 | 1256 | 344 | 2.68 / 71.77 | 2 | 18 |
5 | 13 | 173.24 | 18 | 15.34 | 537 | 148 | 2.83 / 71.91 | 2 | 12 |
6 | 13 | 34.52 | 18 | 15.36 | 331 | 92 | 2.92 / 72.01 | 2 | 15 |
7 | 13 | 28.76 | 18 | 15.36 | 325 | 90 | 3.01 / 72.09 | 2 | 12 |
8 | 8 | 0.20 | 165 | 15.31 | 273 | 690 | 3.70 / 72.78 | 2 | 9 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.04 | 29 | 15.27 | 431 | 191 | 0.19 / 65.57 | 2 | 5 |
2 | 7 | 2010.20 | 38 | 14.96 | 2825 | 1606 | 1.80 / 67.17 | 2 | 15 |
3 | 13 | 1281.56 | 18 | 15.11 | 1951 | 531 | 2.33 / 67.70 | 2 | 16 |
4 | 13 | 776.80 | 18 | 15.21 | 1313 | 359 | 2.69 / 68.06 | 2 | 18 |
5 | 13 | 177.80 | 18 | 15.35 | 540 | 149 | 2.84 / 68.21 | 2 | 21 |
6 | 13 | 39.56 | 18 | 15.37 | 340 | 94 | 2.93 / 68.30 | 2 | 6 |
7 | 13 | 18.72 | 18 | 15.34 | 306 | 84 | 3.01 / 68.39 | 2 | 16 |
8 | 8 | 0.04 | 165 | 15.31 | 274 | 692 | 3.71 / 69.08 | 2 | 17 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.20 | 29 | 15.27 | 438 | 194 | 0.19 / 61.83 | 2 | 3 |
2 | 7 | 2002.92 | 39 | 14.96 | 2817 | 1644 | 1.84 / 63.47 | 2 | 12 |
3 | 13 | 1342.12 | 18 | 15.10 | 2023 | 550 | 2.39 / 64.02 | 2 | 16 |
4 | 13 | 721.16 | 18 | 15.23 | 1244 | 341 | 2.73 / 64.36 | 2 | 19 |
5 | 13 | 134.92 | 18 | 15.35 | 468 | 129 | 2.86 / 64.49 | 2 | 20 |
6 | 13 | 42.72 | 18 | 15.36 | 345 | 95 | 2.95 / 64.59 | 2 | 10 |
7 | 13 | 29.56 | 18 | 15.34 | 323 | 89 | 3.04 / 64.68 | 2 | 14 |
8 | 8 | 0.04 | 165 | 15.31 | 276 | 697 | 3.74 / 65.37 | 2 | 22 |
Average= | 3.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 29 | 15.27 | 401 | 178 | 0.18 / 58.12 | 2 | 5 |
2 | 7 | 2004.16 | 38 | 14.98 | 2820 | 1605 | 1.78 / 59.73 | 2 | 13 |
3 | 13 | 1326.04 | 18 | 15.12 | 2001 | 545 | 2.33 / 60.27 | 2 | 17 |
4 | 13 | 772.12 | 18 | 15.21 | 1325 | 363 | 2.69 / 60.63 | 2 | 18 |
5 | 13 | 135.80 | 18 | 15.36 | 484 | 134 | 2.82 / 60.77 | 2 | 20 |
6 | 13 | 31.32 | 18 | 15.38 | 327 | 91 | 2.91 / 60.86 | 2 | 16 |
7 | 13 | 12.08 | 18 | 15.37 | 299 | 83 | 3.00 / 60.94 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.32 | 275 | 695 | 3.69 / 61.63 | 2 | 9 |
Average= | 3.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 29 | 15.28 | 412 | 183 | 0.18 / 53.73 | 2 | 6 |
2 | 7 | 2010.04 | 74 | 14.85 | 2811 | 3089 | 3.27 / 56.82 | 2 | 14 |
3 | 13 | 462.56 | 18 | 15.29 | 907 | 250 | 3.52 / 57.07 | 2 | 18 |
4 | 13 | 43.64 | 18 | 15.38 | 325 | 90 | 3.61 / 57.16 | 2 | 16 |
5 | 13 | 42.20 | 18 | 15.36 | 325 | 90 | 3.70 / 57.25 | 2 | 24 |
6 | 8 | 0.04 | 165 | 15.31 | 273 | 690 | 4.39 / 57.94 | 2 | 14 |
Average= | 3.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.32 | 29 | 15.28 | 408 | 181 | 0.18 / 49.35 | 2 | 3 |
2 | 7 | 2003.16 | 74 | 14.87 | 2809 | 3091 | 3.27 / 52.44 | 2 | 15 |
3 | 13 | 452.00 | 18 | 15.30 | 894 | 246 | 3.52 / 52.69 | 2 | 19 |
4 | 13 | 43.68 | 18 | 15.38 | 327 | 91 | 3.61 / 52.78 | 2 | 12 |
5 | 13 | 39.40 | 18 | 15.37 | 316 | 87 | 3.70 / 52.87 | 2 | 12 |
6 | 8 | 0.04 | 165 | 15.33 | 270 | 683 | 4.38 / 53.55 | 2 | 14 |
Average= | 3.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.28 | 29 | 15.29 | 433 | 192 | 0.19 / 44.93 | 2 | 3 |
2 | 7 | 2008.00 | 74 | 14.88 | 2815 | 3100 | 3.29 / 48.03 | 2 | 14 |
3 | 13 | 498.84 | 18 | 15.29 | 973 | 268 | 3.56 / 48.30 | 2 | 19 |
4 | 13 | 37.28 | 18 | 15.38 | 336 | 93 | 3.65 / 48.40 | 2 | 12 |
5 | 13 | 35.48 | 18 | 15.37 | 334 | 92 | 3.74 / 48.49 | 2 | 8 |
6 | 8 | -0.04 | 165 | 15.32 | 271 | 685 | 4.43 / 49.17 | 2 | 16 |
Average= | 3.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 29 | 15.29 | 400 | 177 | 0.18 / 40.55 | 2 | 3 |
2 | 7 | 2004.92 | 75 | 14.87 | 2805 | 3128 | 3.31 / 43.68 | 2 | 13 |
3 | 13 | 443.16 | 18 | 15.30 | 881 | 243 | 3.55 / 43.92 | 2 | 18 |
4 | 13 | 39.76 | 18 | 15.38 | 322 | 89 | 3.64 / 44.01 | 2 | 19 |
5 | 13 | 33.24 | 18 | 15.36 | 305 | 84 | 3.72 / 44.09 | 2 | 12 |
6 | 8 | 0.08 | 165 | 15.33 | 257 | 650 | 4.37 / 44.74 | 2 | 11 |
Average= | 3.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.36 | 29 | 15.29 | 428 | 190 | 0.19 / 36.16 | 2 | 3 |
2 | 3 | 1017.40 | 1 | 15.39 | 1670 | 26 | 0.22 / 36.19 | 2 | 13 |
3 | 7 | 2003.16 | 74 | 14.88 | 2806 | 3090 | 3.31 / 39.28 | 2 | 15 |
4 | 13 | 394.60 | 18 | 15.31 | 834 | 230 | 3.54 / 39.51 | 2 | 19 |
5 | 13 | 42.96 | 18 | 15.38 | 345 | 96 | 3.63 / 39.60 | 2 | 18 |
6 | 13 | 33.44 | 18 | 15.36 | 327 | 90 | 3.72 / 39.69 | 2 | 6 |
7 | 8 | 0.00 | 165 | 15.32 | 269 | 680 | 4.40 / 40.37 | 2 | 4 |
Average= | 3.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 28 | 15.30 | 409 | 175 | 0.18 / 31.69 | 2 | 4 |
2 | 3 | 1019.64 | 1 | 15.38 | 1665 | 26 | 0.20 / 31.71 | 2 | 13 |
3 | 7 | 2003.12 | 75 | 14.89 | 2815 | 3144 | 3.34 / 34.85 | 2 | 13 |
4 | 13 | 422.00 | 18 | 15.32 | 870 | 240 | 3.58 / 35.09 | 2 | 20 |
5 | 13 | 37.00 | 18 | 15.40 | 334 | 93 | 3.68 / 35.19 | 2 | 7 |
6 | 13 | 34.16 | 18 | 15.38 | 331 | 92 | 3.77 / 35.28 | 2 | 5 |
7 | 8 | 0.08 | 165 | 15.34 | 273 | 691 | 4.46 / 35.97 | 2 | 9 |
Average= | 3.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 27 | 15.30 | 416 | 172 | 0.17 / 27.47 | 2 | 4 |
2 | 10 | 1001.36 | 2 | 15.33 | 1641 | 50 | 0.22 / 27.52 | 2 | 11 |
3 | 7 | 1877.00 | 74 | 14.94 | 2650 | 2930 | 3.15 / 30.45 | 2 | 15 |
4 | 13 | 322.76 | 18 | 15.35 | 721 | 199 | 3.35 / 30.64 | 2 | 19 |
5 | 13 | 35.04 | 18 | 15.40 | 331 | 92 | 3.44 / 30.74 | 2 | 11 |
6 | 13 | 32.00 | 18 | 15.38 | 326 | 90 | 3.53 / 30.83 | 2 | 9 |
7 | 8 | 0.12 | 165 | 15.35 | 270 | 684 | 4.22 / 31.51 | 2 | 3 |
Average= | 3.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.24 | 29 | 15.28 | 420 | 186 | 0.19 / 23.31 | 2 | 3 |
2 | 3 | 943.08 | -1 | 15.68 | 1 | 0 | 0.00 / 23.31 | 2 | 3 |
3 | 3 | 972.56 | -1 | 15.70 | 1 | 0 | 0.00 / 23.31 | 2 | 3 |
4 | 7 | 1869.16 | 74 | 14.95 | 2641 | 2922 | 3.11 / 26.23 | 2 | 14 |
5 | 13 | 314.08 | 18 | 15.35 | 705 | 195 | 3.30 / 26.43 | 2 | 16 |
6 | 13 | 44.52 | 18 | 15.39 | 326 | 90 | 3.39 / 26.52 | 2 | 15 |
7 | 13 | 21.00 | 18 | 15.39 | 302 | 84 | 3.48 / 26.60 | 2 | 9 |
8 | 8 | 0.00 | 165 | 15.34 | 273 | 691 | 4.17 / 27.29 | 2 | 3 |
Average= | 3.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.36 | 27 | 15.34 | 418 | 173 | 0.17 / 19.32 | 2 | 3 |
2 | 7 | 1698.28 | 74 | 15.00 | 2412 | 2677 | 2.85 / 22.00 | 2 | 14 |
3 | 13 | 321.32 | 18 | 15.36 | 719 | 199 | 3.05 / 22.20 | 2 | 20 |
4 | 13 | 26.08 | 18 | 15.40 | 314 | 87 | 3.14 / 22.28 | 2 | 8 |
5 | 13 | 22.60 | 18 | 15.38 | 310 | 86 | 3.22 / 22.37 | 2 | 12 |
6 | 13 | 12.96 | 18 | 15.38 | 288 | 80 | 3.30 / 22.45 | 2 | 10 |
7 | 8 | 0.00 | 165 | 15.33 | 268 | 678 | 3.98 / 23.13 | 2 | 15 |
Average= | 2.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.08 | 27 | 15.32 | 423 | 175 | 0.17 / 16.40 | 2 | 3 |
2 | 7 | 1087.48 | 74 | 15.23 | 1671 | 1883 | 2.06 / 18.29 | 2 | 16 |
3 | 13 | 30.36 | 18 | 15.45 | 320 | 89 | 2.15 / 18.38 | 2 | 7 |
4 | 13 | 29.08 | 18 | 15.43 | 322 | 89 | 2.24 / 18.47 | 2 | 8 |
5 | 8 | -0.04 | 165 | 15.39 | 268 | 681 | 2.92 / 19.15 | 2 | 8 |
Average= | 2.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.20 | 27 | 15.35 | 415 | 172 | 0.17 / 13.13 | 2 | 4 |
2 | 7 | 1298.00 | 74 | 15.16 | 1932 | 2167 | 2.34 / 15.30 | 2 | 15 |
3 | 13 | 31.20 | 18 | 15.44 | 318 | 88 | 2.43 / 15.38 | 2 | 12 |
4 | 13 | 23.84 | 18 | 15.42 | 310 | 86 | 2.51 / 15.47 | 2 | 11 |
5 | 13 | 22.04 | 18 | 15.41 | 304 | 84 | 2.60 / 15.55 | 2 | 14 |
6 | 8 | 0.12 | 165 | 15.36 | 266 | 674 | 3.27 / 16.23 | 2 | 13 |
Average= | 2.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.44 | 27 | 15.35 | 428 | 177 | 0.18 / 10.29 | 2 | 4 |
2 | 7 | 1069.20 | 74 | 15.25 | 1646 | 1858 | 2.03 / 12.15 | 2 | 15 |
3 | 13 | 19.04 | 18 | 15.46 | 302 | 84 | 2.12 / 12.23 | 2 | 18 |
4 | 8 | 18.16 | 165 | 15.41 | 286 | 727 | 2.85 / 12.96 | 2 | 8 |
Average= | 2.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 26 | 15.35 | 399 | 159 | 0.16 / 7.24 | 2 | 3 |
2 | 3 | 1037.96 | 1 | 15.36 | 1683 | 26 | 0.19 / 7.26 | 2 | 12 |
3 | 7 | 1118.92 | 74 | 15.22 | 1697 | 1911 | 2.10 / 9.18 | 2 | 15 |
4 | 13 | 24.36 | 18 | 15.46 | 311 | 87 | 2.18 / 9.26 | 2 | 3 |
5 | 13 | 20.96 | 18 | 15.44 | 308 | 86 | 2.27 / 9.35 | 2 | 15 |
6 | 13 | 8.52 | 18 | 15.42 | 288 | 80 | 2.35 / 9.43 | 2 | 13 |
7 | 8 | 0.00 | 165 | 15.38 | 269 | 683 | 3.03 / 10.11 | 2 | 21 |
Average= | 2.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 32 | 15.34 | 403 | 198 | 0.20 / 4.41 | 2 | 3 |
2 | 3 | 828.80 | -3 | 15.70 | 1 | 0 | 0.00 / 4.41 | 2 | 3 |
3 | 3 | 922.64 | -1 | 15.73 | 1 | 0 | 0.00 / 4.41 | 2 | 3 |
4 | 7 | 1055.24 | 74 | 15.27 | 1610 | 1819 | 2.02 / 6.23 | 2 | 16 |
5 | 13 | 38.80 | 18 | 15.47 | 325 | 90 | 2.11 / 6.32 | 2 | 15 |
6 | 13 | 35.32 | 18 | 15.45 | 320 | 89 | 2.20 / 6.41 | 2 | 17 |
7 | 8 | 0.28 | 165 | 15.40 | 263 | 668 | 2.86 / 7.08 | 2 | 6 |
Average= | 2.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.32 | 27 | 15.51 | 379 | 159 | 0.16 / 1.63 | 2 | 3 |
2 | 7 | 998.92 | 74 | 15.26 | 1543 | 1742 | 1.90 / 3.38 | 2 | 13 |
3 | 13 | 30.44 | 18 | 15.46 | 311 | 87 | 1.99 / 3.46 | 2 | 8 |
4 | 13 | 28.36 | 18 | 15.44 | 310 | 86 | 2.07 / 3.55 | 2 | 7 |
5 | 8 | 0.12 | 165 | 15.40 | 262 | 666 | 2.74 / 4.21 | 2 | 10 |
Average= | 2.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.48 | 26 | 15.66 | 349 | 142 | 0.14 / 0.14 | 2 | 2 |
2 | 7 | 118.92 | 74 | 15.63 | 373 | 431 | 0.57 / 0.57 | 2 | 3 |
3 | 13 | 21.40 | 18 | 15.63 | 254 | 71 | 0.64 / 0.64 | 2 | 2 |
4 | 8 | 0.16 | 240 | 15.58 | 222 | 830 | 1.48 / 1.48 | 2 | 8 |
Average= | 1.48 (KJ/cycle) |