SIO Argo Site:
Pump Diagnostics Page   



Serial= 3153 WMO= 3902294

Return

←PreviousNext→

Cycle 74 GMT 18/11/2024 10:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.40 28 15.09 430 182 0.18 / 263.08 2 2
2 7 2004.04 38 14.68 2923 1631 1.81 / 264.71 2 5
3 13 1217.16 18 14.83 1934 516 2.33 / 265.23 2 4
4 13 836.76 18 14.90 1450 389 2.72 / 265.62 2 3
5 13 230.52 18 15.10 609 166 2.88 / 265.78 2 3
6 8 0.00 165 15.13 270 674 3.56 / 266.46 2 9
Average= 3.55
(KJ/cycle)

Cycle 73 GMT 8/11/2024 14:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 28 15.09 418 177 0.18 / 259.55 2 3
2 7 2010.88 38 14.67 2932 1634 1.81 / 261.19 2 3
3 13 1222.52 18 14.82 1951 520 2.33 / 261.71 2 3
4 13 703.68 18 14.95 1266 341 2.67 / 262.05 2 3
5 13 247.88 18 15.09 632 172 2.84 / 262.22 2 3
6 8 -0.04 165 15.13 271 677 3.52 / 262.90 2 13
Average= 3.55
(KJ/cycle)

Cycle 72 GMT 29/10/2024 19:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.40 28 15.08 433 183 0.18 / 256.00 2 3
2 7 2004.04 38 14.66 2934 1634 1.82 / 257.64 2 3
3 13 1280.28 18 14.81 2016 537 2.35 / 258.18 2 4
4 13 697.04 18 14.96 1252 337 2.69 / 258.51 2 4
5 13 284.80 18 15.09 690 187 2.88 / 258.70 2 3
6 8 0.20 165 15.13 271 677 3.56 / 259.38 2 6
Average= 3.55
(KJ/cycle)

Cycle 71 GMT 20/10/2024 0:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.80 28 15.11 422 179 0.18 / 252.44 2 3
2 7 2003.92 38 14.68 2918 1628 1.81 / 254.07 2 4
3 13 1260.08 18 14.84 1979 529 2.33 / 254.60 2 5
4 13 770.36 18 14.95 1355 365 2.70 / 254.96 2 3
5 13 248.80 18 15.11 639 174 2.87 / 255.14 2 3
6 8 0.72 165 15.15 274 685 3.56 / 255.82 2 12
Average= 3.55
(KJ/cycle)

Cycle 70 GMT 10/10/2024 4:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.72 28 15.11 424 179 0.18 / 248.91 2 3
2 7 2013.48 38 14.68 2948 1645 1.82 / 250.56 2 3
3 13 1227.76 18 14.85 1952 522 2.35 / 251.08 2 4
4 13 734.28 18 14.96 1303 351 2.70 / 251.43 2 3
5 13 226.64 18 15.12 604 164 2.86 / 251.59 2 3
6 8 0.00 165 15.15 268 670 3.53 / 252.26 2 11
Average= 3.55
(KJ/cycle)

Cycle 69 GMT 30/ 9/2024 9:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 28 15.12 421 178 0.18 / 245.30 2 3
2 7 2006.92 38 14.68 2944 1642 1.82 / 246.94 2 4
3 13 1354.80 18 14.83 2110 563 2.38 / 247.50 2 3
4 13 749.12 18 14.97 1323 356 2.74 / 247.86 2 4
5 13 278.60 18 15.11 684 186 2.93 / 248.04 2 4
6 8 0.00 165 15.16 275 688 3.61 / 248.73 2 11
Average= 3.55
(KJ/cycle)

Cycle 68 GMT 20/ 9/2024 14:30: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 28 15.10 424 179 0.18 / 241.66 2 2
2 7 2008.96 39 14.67 2946 1685 1.86 / 243.34 2 3
3 13 1382.72 18 14.80 2147 572 2.44 / 243.92 2 5
4 13 721.12 18 14.98 1287 347 2.78 / 244.26 2 3
5 13 254.76 18 15.13 650 177 2.96 / 244.44 2 3
6 8 -0.52 165 15.16 271 678 3.64 / 245.12 2 13
Average= 3.55
(KJ/cycle)

Cycle 67 GMT 10/ 9/2024 19:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 28 15.12 417 177 0.18 / 238.11 2 2
2 7 2008.48 38 14.67 2932 1634 1.81 / 239.74 2 4
3 13 1278.64 18 14.84 1990 532 2.34 / 240.27 2 4
4 13 729.56 18 14.97 1302 351 2.69 / 240.62 2 3
5 13 265.04 18 15.12 661 180 2.87 / 240.80 2 4
6 8 0.32 165 15.15 271 677 3.55 / 241.48 2 12
Average= 3.55
(KJ/cycle)

Cycle 66 GMT 1/ 9/2024 0: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.04 28 15.11 430 182 0.18 / 234.57 2 2
2 7 2011.88 38 14.68 2938 1639 1.82 / 236.21 2 4
3 13 1221.28 18 14.86 1929 516 2.34 / 236.73 2 4
4 13 694.08 18 14.99 1254 338 2.68 / 237.07 2 4
5 13 271.44 18 15.11 667 181 2.86 / 237.25 2 4
6 8 0.52 165 15.15 272 680 3.54 / 237.93 2 7
Average= 3.55
(KJ/cycle)

Cycle 65 GMT 22/ 8/2024 4:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 28 15.12 430 182 0.18 / 231.05 2 3
2 7 2003.48 38 14.69 2918 1629 1.81 / 232.68 2 4
3 13 1286.12 18 14.83 2024 540 2.35 / 233.22 2 4
4 13 662.32 18 15.00 1209 326 2.68 / 233.55 2 3
5 13 235.28 18 15.12 617 168 2.85 / 233.72 2 3
6 8 -0.08 165 15.16 270 675 3.52 / 234.39 2 10
Average= 3.55
(KJ/cycle)

Cycle 64 GMT 12/ 8/2024 9:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 28 15.13 411 174 0.17 / 227.44 2 2
2 7 2011.76 39 14.69 2931 1679 1.85 / 229.12 2 3
3 13 1344.00 18 14.83 2101 561 2.41 / 229.68 2 4
4 13 697.60 18 14.99 1262 341 2.75 / 230.03 2 3
5 13 246.76 18 15.13 635 173 2.93 / 230.20 2 4
6 8 -0.40 165 15.17 269 673 3.60 / 230.87 2 11
Average= 3.55
(KJ/cycle)

Cycle 63 GMT 2/ 8/2024 13:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.60 28 15.13 414 175 0.18 / 223.89 2 2
2 7 2002.36 38 14.69 2922 1631 1.81 / 225.52 2 4
3 13 1284.68 18 14.84 2011 537 2.34 / 226.06 2 4
4 13 740.96 18 14.97 1321 356 2.70 / 226.42 2 3
5 13 268.20 18 15.12 664 181 2.88 / 226.60 2 4
6 8 0.60 165 15.16 269 673 3.55 / 227.27 2 13
Average= 3.55
(KJ/cycle)

Cycle 62 GMT 23/ 7/2024 18:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 28 15.12 424 180 0.18 / 220.37 2 3
2 7 2004.64 38 14.69 2913 1626 1.81 / 222.00 2 4
3 13 1293.04 18 14.86 2032 544 2.35 / 222.54 2 4
4 13 703.08 18 15.00 1263 341 2.69 / 222.88 2 3
5 13 238.68 18 15.14 620 169 2.86 / 223.05 2 3
6 8 0.72 165 15.18 266 666 3.53 / 223.72 2 7
Average= 3.55
(KJ/cycle)

Cycle 61 GMT 13/ 7/2024 23:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 28 15.13 416 176 0.18 / 216.80 2 2
2 7 2004.12 38 14.70 2909 1625 1.80 / 218.43 2 3
3 13 1283.32 18 14.85 2023 541 2.34 / 218.97 2 3
4 13 737.80 18 14.99 1317 355 2.70 / 219.33 2 4
5 13 260.24 18 15.13 655 178 2.88 / 219.50 2 4
6 8 0.60 165 15.17 275 688 3.56 / 220.19 2 10
Average= 3.55
(KJ/cycle)

Cycle 60 GMT 4/ 7/2024 4: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 28 15.13 400 169 0.17 / 213.18 2 2
2 7 2004.32 38 14.70 2912 1627 1.80 / 214.80 2 3
3 13 1369.48 18 14.84 2133 570 2.37 / 215.37 2 4
4 13 858.28 18 14.94 1463 393 2.76 / 215.77 2 4
5 13 273.00 18 15.13 674 184 2.94 / 215.95 2 4
6 8 -0.24 165 15.17 271 678 3.62 / 216.63 2 15
Average= 3.55
(KJ/cycle)

Cycle 59 GMT 24/ 6/2024 9: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.64 28 15.14 419 178 0.18 / 209.70 2 3
2 7 2006.68 38 14.69 2929 1635 1.81 / 211.33 2 4
3 13 1287.08 18 14.86 2013 538 2.35 / 211.87 2 4
4 13 620.80 18 15.03 1159 314 2.66 / 212.18 2 4
5 13 188.56 18 15.16 546 149 2.81 / 212.33 2 4
6 8 0.04 165 15.17 269 673 3.49 / 213.01 2 10
Average= 3.55
(KJ/cycle)

Cycle 58 GMT 14/ 6/2024 13:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.64 28 15.12 427 181 0.18 / 206.22 2 2
2 7 2004.44 38 14.70 2926 1634 1.82 / 207.86 2 6
3 13 1199.16 18 14.90 1901 510 2.33 / 208.37 2 5
4 13 667.80 18 15.03 1219 330 2.65 / 208.70 2 4
5 13 189.68 18 15.18 548 150 2.80 / 208.85 2 4
6 8 0.48 165 15.19 268 672 3.48 / 209.52 2 13
Average= 3.55
(KJ/cycle)

Cycle 57 GMT 4/ 6/2024 18:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.04 28 15.16 416 177 0.18 / 202.67 2 3
2 7 2008.88 38 14.69 2933 1637 1.81 / 204.31 2 4
3 13 1246.20 18 14.87 1984 531 2.34 / 204.84 2 4
4 13 753.36 18 14.99 1334 360 2.70 / 205.20 2 4
5 13 237.92 18 15.16 618 169 2.87 / 205.37 2 4
6 8 -0.24 165 15.18 269 674 3.55 / 206.04 2 14
Average= 3.55
(KJ/cycle)

Cycle 56 GMT 25/ 5/2024 23: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.12 28 15.15 422 179 0.18 / 199.11 2 2
2 7 2010.68 38 14.70 2946 1646 1.82 / 200.76 2 4
3 13 1309.76 18 14.87 2046 548 2.37 / 201.31 2 6
4 13 753.20 18 15.00 1332 360 2.73 / 201.67 2 3
5 13 209.12 18 15.18 576 157 2.89 / 201.82 2 3
6 8 -0.20 165 15.19 268 672 3.56 / 202.50 2 7
Average= 3.55
(KJ/cycle)

Cycle 55 GMT 16/ 5/2024 3:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 28 15.15 406 172 0.17 / 195.54 2 2
2 7 2006.52 39 14.70 2928 1679 1.85 / 197.22 2 3
3 13 1247.32 18 14.88 1966 527 2.38 / 197.75 2 3
4 13 704.60 18 15.02 1267 343 2.72 / 198.09 2 4
5 13 247.52 18 15.15 632 172 2.89 / 198.26 2 3
6 8 0.52 165 15.18 269 674 3.57 / 198.94 2 12
Average= 3.55
(KJ/cycle)

Cycle 54 GMT 6/ 5/2024 8:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.96 28 15.15 413 175 0.18 / 192.00 2 3
2 7 2003.80 38 14.69 2933 1637 1.81 / 193.64 2 3
3 13 1266.96 18 14.87 2000 535 2.35 / 194.17 2 4
4 13 692.32 18 15.02 1252 338 2.69 / 194.51 2 3
5 13 279.80 18 15.15 680 185 2.87 / 194.70 2 4
6 8 0.36 165 15.18 269 674 3.55 / 195.37 2 15
Average= 3.55
(KJ/cycle)

Cycle 53 GMT 26/ 4/2024 13:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 28 15.16 418 177 0.18 / 188.49 2 3
2 7 2003.04 38 14.71 2925 1635 1.81 / 190.12 2 3
3 13 1223.96 18 14.90 1950 523 2.34 / 190.64 2 4
4 13 678.88 18 15.03 1226 332 2.67 / 190.98 2 3
5 13 262.28 18 15.16 657 179 2.85 / 191.15 2 4
6 8 -0.28 165 15.20 267 670 3.52 / 191.82 2 11
Average= 3.55
(KJ/cycle)

Cycle 52 GMT 16/ 4/2024 18: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.24 28 15.16 413 175 0.18 / 184.91 2 2
2 7 2006.08 38 14.72 2931 1639 1.81 / 186.55 2 3
3 13 1259.44 18 14.90 1985 532 2.35 / 187.08 2 6
4 13 774.40 18 15.01 1371 370 2.72 / 187.45 2 4
5 13 258.92 18 15.17 653 178 2.90 / 187.63 2 4
6 8 -0.12 165 15.20 269 675 3.57 / 188.31 2 13
Average= 3.55
(KJ/cycle)

Cycle 51 GMT 6/ 4/2024 22:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 28 15.17 422 179 0.18 / 181.31 2 3
2 7 2005.52 38 14.72 2928 1638 1.82 / 182.95 2 4
3 13 1319.00 18 14.88 2076 556 2.37 / 183.51 2 5
4 13 758.44 18 15.03 1345 364 2.74 / 183.87 2 4
5 13 281.72 18 15.18 688 188 2.92 / 184.06 2 4
6 8 0.04 165 15.21 270 678 3.60 / 184.74 2 11
Average= 3.55
(KJ/cycle)

Cycle 50 GMT 28/ 3/2024 3:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 28 15.17 413 175 0.18 / 177.70 2 2
2 7 2003.72 39 14.71 2928 1680 1.86 / 179.38 2 4
3 13 1321.16 18 14.89 2078 557 2.41 / 179.94 2 3
4 13 683.52 18 15.04 1247 338 2.75 / 180.27 2 4
5 13 265.60 18 15.18 666 182 2.93 / 180.46 2 4
6 8 0.00 165 15.20 271 680 3.61 / 181.13 2 11
Average= 3.55
(KJ/cycle)

Cycle 49 GMT 18/ 3/2024 8: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.04 28 15.16 429 182 0.18 / 174.17 2 2
2 7 2010.88 38 14.72 2926 1637 1.82 / 175.81 2 4
3 13 1199.68 18 14.94 1929 519 2.34 / 176.33 2 4
4 13 663.24 18 15.07 1214 329 2.67 / 176.66 2 4
5 13 256.44 18 15.19 653 179 2.85 / 176.84 2 4
6 8 -0.44 165 15.22 274 688 3.53 / 177.52 2 11
Average= 3.55
(KJ/cycle)

Cycle 48 GMT 8/ 3/2024 12:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 28 15.19 419 178 0.18 / 170.63 2 2
2 7 2009.88 38 14.71 2933 1639 1.82 / 172.26 2 3
3 13 1208.32 18 14.91 1930 518 2.34 / 172.78 2 4
4 13 729.84 18 15.03 1305 353 2.69 / 173.14 2 5
5 13 258.04 18 15.17 647 177 2.87 / 173.31 2 4
6 8 0.44 165 15.21 270 678 3.54 / 173.99 2 11
Average= 3.55
(KJ/cycle)

Cycle 47 GMT 27/ 2/2024 17:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.00 28 15.17 432 183 0.18 / 167.10 2 2
2 7 2010.08 39 14.73 2921 1678 1.86 / 168.77 2 3
3 13 1247.88 18 14.91 1962 527 2.39 / 169.30 2 5
4 13 634.88 18 15.08 1177 319 2.71 / 169.62 2 3
5 13 197.48 18 15.21 561 154 2.86 / 169.77 2 3
6 8 -0.08 165 15.21 268 673 3.53 / 170.45 2 6
Average= 3.55
(KJ/cycle)

Cycle 46 GMT 17/ 2/2024 21:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.60 28 15.18 421 179 0.18 / 163.54 2 3
2 7 2004.36 38 14.72 2928 1638 1.82 / 165.17 2 4
3 13 1280.92 18 14.90 2023 543 2.36 / 165.72 2 4
4 13 720.28 18 15.05 1292 350 2.71 / 166.07 2 3
5 13 219.24 18 15.21 598 164 2.87 / 166.23 2 4
6 8 -0.68 165 15.22 272 683 3.56 / 166.91 2 13
Average= 3.55
(KJ/cycle)

Cycle 45 GMT 8/ 2/2024 2:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 28 15.19 414 176 0.18 / 159.96 2 2
2 7 2004.68 38 14.72 2928 1638 1.81 / 161.60 2 4
3 13 1334.76 18 14.89 2095 562 2.38 / 162.16 2 5
4 13 730.16 18 15.04 1311 355 2.73 / 162.52 2 4
5 13 226.76 18 15.21 604 165 2.90 / 162.68 2 3
6 8 0.20 165 15.22 269 676 3.57 / 163.36 2 14
Average= 3.55
(KJ/cycle)

Cycle 44 GMT 29/ 1/2024 7:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 28 15.21 415 177 0.18 / 156.34 2 3
2 7 2003.88 39 14.72 2928 1681 1.86 / 158.02 2 5
3 13 1314.36 18 14.89 2066 554 2.41 / 158.57 2 5
4 13 720.64 18 15.05 1294 351 2.76 / 158.92 2 3
5 13 257.80 18 15.19 652 178 2.94 / 159.10 2 4
6 8 -0.08 165 15.22 272 683 3.62 / 159.79 2 4
Average= 3.55
(KJ/cycle)

Cycle 43 GMT 19/ 1/2024 12: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.40 28 15.19 431 183 0.18 / 152.75 2 3
2 7 2009.24 39 14.74 2933 1686 1.87 / 154.44 2 3
3 13 1328.96 18 14.90 2083 559 2.43 / 155.00 2 4
4 13 693.12 18 15.06 1253 340 2.77 / 155.34 2 3
5 13 190.08 18 15.22 547 150 2.92 / 155.49 2 4
6 8 0.00 165 15.23 268 673 3.59 / 156.16 2 16
Average= 3.55
(KJ/cycle)

Cycle 42 GMT 9/ 1/2024 16:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.28 28 15.20 433 184 0.18 / 149.15 2 3
2 7 2002.84 38 14.74 2927 1639 1.82 / 150.79 2 3
3 13 1287.40 18 14.92 2032 546 2.37 / 151.34 2 3
4 13 752.48 18 15.05 1332 361 2.73 / 151.70 2 4
5 13 281.24 18 15.20 685 187 2.92 / 151.89 2 4
6 8 -0.48 165 15.24 273 686 3.60 / 152.57 2 11
Average= 3.55
(KJ/cycle)

Cycle 41 GMT 30/12/2023 21:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 28 15.20 423 180 0.18 / 145.56 2 2
2 7 2009.80 39 14.73 2939 1688 1.87 / 147.25 2 4
3 13 1239.32 18 14.92 1974 530 2.40 / 147.78 2 3
4 13 706.92 18 15.07 1277 346 2.74 / 148.12 2 4
5 13 204.24 18 15.22 572 157 2.90 / 148.28 2 3
6 8 -0.20 165 15.24 273 686 3.59 / 148.97 2 13
Average= 3.55
(KJ/cycle)

Cycle 40 GMT 21/12/2023 2:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 28 15.20 416 177 0.18 / 142.01 2 3
2 7 2005.52 38 14.73 2925 1637 1.81 / 143.64 2 5
3 13 1284.08 18 14.91 2031 545 2.36 / 144.19 2 4
4 13 693.00 18 15.07 1254 340 2.70 / 144.53 2 4
5 13 238.44 18 15.21 622 170 2.87 / 144.70 2 4
6 8 -0.12 165 15.23 271 681 3.55 / 145.38 2 13
Average= 3.55
(KJ/cycle)

Cycle 39 GMT 11/12/2023 6:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 27 15.20 427 175 0.18 / 138.45 2 2
2 7 2005.96 39 14.74 2932 1685 1.86 / 140.13 2 5
3 13 1203.52 18 14.95 1925 518 2.38 / 140.65 2 5
4 13 671.24 18 15.09 1223 332 2.71 / 140.98 2 4
5 13 223.92 18 15.22 603 165 2.88 / 141.15 2 4
6 8 0.32 165 15.24 271 681 3.56 / 141.83 2 13
Average= 3.55
(KJ/cycle)

Cycle 38 GMT 1/12/2023 11:30: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 27 15.22 425 175 0.17 / 134.87 2 3
2 7 2007.68 38 14.74 2935 1644 1.82 / 136.52 2 3
3 13 1229.68 18 14.94 1960 527 2.35 / 137.04 2 6
4 13 779.88 18 15.05 1376 373 2.72 / 137.42 2 4
5 13 251.32 18 15.22 640 175 2.89 / 137.59 2 4
6 8 0.48 165 15.24 270 679 3.57 / 138.27 2 6
Average= 3.55
(KJ/cycle)

Cycle 37 GMT 21/11/2023 16:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 27 15.19 423 173 0.17 / 131.27 2 2
2 7 2006.44 38 14.74 2925 1638 1.81 / 132.91 2 4
3 13 1311.52 18 14.92 2065 555 2.37 / 133.47 2 5
4 13 744.04 18 15.06 1329 360 2.73 / 133.83 2 4
5 13 264.76 18 15.22 666 182 2.91 / 134.01 2 4
6 8 -0.36 165 15.25 274 689 3.60 / 134.70 2 9
Average= 3.54
(KJ/cycle)

Cycle 36 GMT 11/11/2023 21: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 27 15.21 425 175 0.17 / 127.71 2 3
2 7 2007.52 38 14.74 2932 1642 1.82 / 129.35 2 4
3 13 1218.60 18 14.95 1925 518 2.33 / 129.87 2 4
4 13 720.08 18 15.08 1293 351 2.69 / 130.22 2 4
5 13 251.40 18 15.22 650 178 2.86 / 130.40 2 4
6 8 0.00 165 15.23 279 701 3.56 / 131.10 2 15
Average= 3.54
(KJ/cycle)

Cycle 35 GMT 2/11/2023 1:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.76 27 15.22 430 177 0.18 / 124.13 2 2
2 7 2002.76 38 14.75 2925 1639 1.82 / 125.77 2 4
3 13 1273.56 18 14.93 2018 542 2.36 / 126.31 2 5
4 13 724.72 18 15.08 1296 352 2.71 / 126.66 2 3
5 13 264.28 18 15.21 667 183 2.89 / 126.84 2 4
6 8 -0.24 165 15.25 275 692 3.58 / 127.53 2 13
Average= 3.54
(KJ/cycle)

Cycle 34 GMT 23/10/2023 6:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 27 15.21 426 175 0.17 / 120.51 2 2
2 7 2012.44 39 14.76 2947 1696 1.87 / 122.21 2 3
3 13 1292.76 18 14.94 2039 548 2.42 / 122.76 2 4
4 13 652.08 18 15.11 1200 326 2.75 / 123.08 2 4
5 13 248.00 18 15.23 644 177 2.92 / 123.26 2 4
6 8 0.04 165 15.25 274 689 3.61 / 123.95 2 11
Average= 3.54
(KJ/cycle)

Cycle 33 GMT 13/10/2023 11:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.20 27 15.21 430 177 0.18 / 116.96 2 3
2 7 2009.96 38 14.75 2934 1645 1.82 / 118.61 2 4
3 13 1238.20 18 14.95 1977 532 2.35 / 119.14 2 5
4 13 696.84 18 15.09 1260 342 2.70 / 119.48 2 3
5 13 235.84 18 15.23 620 170 2.87 / 119.65 2 3
6 8 -0.24 165 15.25 272 684 3.55 / 120.34 2 6
Average= 3.54
(KJ/cycle)

Cycle 32 GMT 3/10/2023 15:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 27 15.23 418 172 0.17 / 113.38 2 3
2 7 2005.24 38 14.76 2934 1646 1.82 / 115.02 2 4
3 13 1265.64 18 14.95 2002 539 2.36 / 115.56 2 4
4 13 754.40 18 15.08 1345 365 2.72 / 115.93 2 5
5 13 235.88 18 15.24 625 171 2.89 / 116.10 2 4
6 8 0.12 165 15.26 274 690 3.58 / 116.79 2 14
Average= 3.54
(KJ/cycle)

Cycle 31 GMT 23/ 9/2023 20:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 27 15.23 421 173 0.17 / 109.74 2 3
2 7 2002.32 38 14.76 2929 1643 1.82 / 111.38 2 3
3 13 1359.60 18 14.92 2115 568 2.38 / 111.95 2 5
4 13 836.56 18 15.06 1453 394 2.78 / 112.34 2 4
5 13 252.48 18 15.23 647 177 2.96 / 112.52 2 4
6 8 0.00 165 15.26 272 685 3.64 / 113.21 2 15
Average= 3.54
(KJ/cycle)

Cycle 30 GMT 14/ 9/2023 1:23:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 27 15.23 421 173 0.17 / 106.15 2 2
2 7 2003.88 38 14.76 2933 1645 1.82 / 107.79 2 4
3 13 1277.96 18 14.95 2021 544 2.36 / 108.34 2 4
4 13 737.52 18 15.08 1322 359 2.72 / 108.70 2 3
5 13 262.84 18 15.23 660 181 2.90 / 108.88 2 3
6 8 0.08 165 15.25 273 687 3.59 / 109.57 2 10
Average= 3.53
(KJ/cycle)

Cycle 29 GMT 4/ 9/2023 6: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.76 27 15.23 422 174 0.17 / 102.57 2 2
2 7 2010.52 38 14.76 2948 1653 1.83 / 104.22 2 3
3 13 1202.88 18 14.98 1928 520 2.35 / 104.74 2 3
4 13 748.32 18 15.09 1334 362 2.71 / 105.10 2 5
5 13 270.08 18 15.23 675 185 2.89 / 105.29 2 4
6 8 -0.16 165 15.27 274 690 3.58 / 105.98 2 11
Average= 3.53
(KJ/cycle)

Cycle 28 GMT 25/ 8/2023 10:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.04 27 15.23 424 174 0.17 / 99.02 2 3
2 7 2003.76 38 14.78 2934 1648 1.82 / 100.67 2 4
3 13 1273.52 18 14.96 2023 545 2.37 / 101.22 2 4
4 13 676.84 18 15.12 1233 336 2.70 / 101.55 2 4
5 13 201.12 18 15.26 569 156 2.86 / 101.71 2 3
6 8 0.68 165 15.28 271 683 3.54 / 102.39 2 12
Average= 3.53
(KJ/cycle)

Cycle 27 GMT 15/ 8/2023 15:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 27 15.25 421 173 0.17 / 95.45 2 2
2 7 2004.12 38 14.78 2937 1650 1.82 / 97.10 2 4
3 13 1209.76 18 14.99 1944 525 2.35 / 97.62 2 6
4 13 751.36 18 15.10 1336 363 2.71 / 97.98 2 4
5 13 243.48 18 15.25 631 173 2.88 / 98.16 2 4
6 8 0.04 165 15.28 275 693 3.58 / 98.85 2 13
Average= 3.53
(KJ/cycle)

Cycle 26 GMT 5/ 8/2023 20:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.20 27 15.23 426 175 0.18 / 91.86 2 2
2 7 2003.00 38 14.78 2934 1648 1.82 / 93.51 2 3
3 13 1328.96 18 14.95 2083 561 2.38 / 94.07 2 6
4 13 688.80 18 15.13 1255 342 2.73 / 94.41 2 4
5 13 240.64 18 15.25 629 173 2.90 / 94.58 2 4
6 8 0.04 165 15.28 273 688 3.59 / 95.27 2 11
Average= 3.53
(KJ/cycle)

Cycle 25 GMT 27/ 7/2023 0:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.60 27 15.23 426 175 0.18 / 88.31 2 2
2 7 2005.00 38 14.77 2932 1646 1.82 / 89.96 2 4
3 13 1213.36 18 14.99 1938 523 2.34 / 90.48 2 4
4 13 677.52 18 15.11 1239 337 2.68 / 90.82 2 4
5 13 266.48 18 15.24 666 183 2.86 / 91.00 2 3
6 8 0.20 165 15.28 273 688 3.55 / 91.69 2 7
Average= 3.53
(KJ/cycle)

Cycle 24 GMT 17/ 7/2023 5:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 27 15.24 419 172 0.17 / 84.75 2 3
2 7 2003.00 38 14.78 2920 1640 1.81 / 86.39 2 3
3 13 1236.92 18 14.99 1959 529 2.34 / 86.92 2 4
4 13 707.68 18 15.11 1281 348 2.69 / 87.27 2 4
5 13 251.84 18 15.24 646 177 2.87 / 87.44 2 4
6 8 0.28 165 15.28 274 691 3.56 / 88.13 2 11
Average= 3.53
(KJ/cycle)

Cycle 23 GMT 7/ 7/2023 10:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.96 27 15.25 433 178 0.18 / 81.15 2 2
2 7 2003.00 38 14.79 2943 1654 1.83 / 82.80 2 4
3 13 1284.56 18 14.98 2034 548 2.38 / 83.35 2 5
4 13 776.84 18 15.09 1372 373 2.75 / 83.72 2 3
5 13 215.92 18 15.26 593 163 2.92 / 83.89 2 4
6 8 0.44 165 15.29 274 691 3.61 / 84.58 2 15
Average= 3.52
(KJ/cycle)

Cycle 22 GMT 27/ 6/2023 15: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 27 15.25 415 171 0.17 / 77.60 2 2
2 7 2005.64 38 14.79 2937 1651 1.82 / 79.25 2 3
3 13 1239.56 18 14.99 1983 535 2.36 / 79.79 2 5
4 13 686.52 18 15.12 1254 341 2.70 / 80.13 2 4
5 13 195.52 18 15.28 556 153 2.85 / 80.28 2 3
6 8 -0.08 165 15.30 273 689 3.54 / 80.97 2 7
Average= 3.52
(KJ/cycle)

Cycle 21 GMT 17/ 6/2023 19:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 27 15.26 417 172 0.17 / 74.04 2 2
2 7 2010.48 38 14.79 2935 1650 1.82 / 75.69 2 4
3 13 1234.84 18 14.99 1970 532 2.35 / 76.22 2 3
4 13 692.92 18 15.14 1261 344 2.70 / 76.57 2 4
5 13 236.08 18 15.26 618 170 2.87 / 76.74 2 3
6 8 0.12 165 15.29 275 694 3.56 / 77.43 2 7
Average= 3.52
(KJ/cycle)

Cycle 20 GMT 8/ 6/2023 0:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 27 15.26 417 172 0.17 / 70.49 2 2
2 7 2004.84 38 14.79 2930 1647 1.82 / 72.14 2 3
3 13 1234.48 18 14.99 1952 527 2.35 / 72.67 2 4
4 13 668.56 18 15.13 1227 334 2.68 / 73.00 2 3
5 13 256.76 18 15.24 652 179 2.86 / 73.18 2 4
6 8 0.40 165 15.28 273 688 3.55 / 73.87 2 14
Average= 3.52
(KJ/cycle)

Cycle 19 GMT 29/ 5/2023 5:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 27 15.25 399 164 0.16 / 66.90 2 2
2 7 2004.36 38 14.79 2935 1650 1.81 / 68.55 2 4
3 13 1323.76 18 14.98 2088 563 2.38 / 69.12 2 6
4 13 732.88 18 15.12 1317 358 2.74 / 69.48 2 4
5 13 222.40 18 15.28 598 164 2.90 / 69.64 2 3
6 8 -0.08 165 15.28 271 683 3.58 / 70.32 2 15
Average= 3.52
(KJ/cycle)

Cycle 18 GMT 19/ 5/2023 9:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.60 27 15.26 429 177 0.18 / 63.37 2 3
2 7 2003.80 38 14.79 2925 1644 1.82 / 65.01 2 4
3 13 1203.24 18 15.00 1932 522 2.34 / 65.53 2 5
4 13 711.20 18 15.13 1284 350 2.69 / 65.88 2 4
5 13 248.04 18 15.27 639 176 2.87 / 66.06 2 4
6 8 0.28 165 15.29 271 684 3.55 / 66.74 2 17
Average= 3.51
(KJ/cycle)

Cycle 17 GMT 9/ 5/2023 14:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 27 15.25 420 173 0.17 / 59.81 2 3
2 7 2003.20 38 14.80 2925 1645 1.82 / 61.45 2 3
3 13 1280.96 18 14.99 2024 546 2.36 / 62.00 2 5
4 13 759.76 18 15.12 1345 366 2.73 / 62.36 2 5
5 13 151.16 18 15.29 493 136 2.87 / 62.50 2 3
6 8 0.32 165 15.30 273 689 3.55 / 63.19 2 16
Average= 3.51
(KJ/cycle)

Cycle 16 GMT 29/ 4/2023 19:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.28 27 15.25 425 175 0.17 / 56.27 2 6
2 7 2002.96 38 14.79 2918 1640 1.81 / 57.91 2 3
3 13 1185.56 18 15.01 1904 514 2.33 / 58.42 2 5
4 13 701.96 18 15.13 1273 347 2.68 / 58.77 2 4
5 13 240.36 18 15.27 629 173 2.85 / 58.94 2 4
6 8 0.44 165 15.29 275 694 3.54 / 59.63 2 19
Average= 3.51
(KJ/cycle)

Cycle 15 GMT 19/ 4/2023 23:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 27 15.26 408 168 0.17 / 52.72 2 3
2 7 2003.60 38 14.80 2939 1653 1.82 / 54.37 2 3
3 13 1218.56 18 15.00 1947 526 2.35 / 54.89 2 5
4 13 684.64 18 15.14 1245 339 2.69 / 55.23 2 4
5 13 230.32 18 15.27 613 168 2.85 / 55.40 2 4
6 8 -0.20 165 15.29 273 689 3.54 / 56.09 2 11
Average= 3.51
(KJ/cycle)

Cycle 14 GMT 10/ 4/2023 4:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 27 15.27 424 175 0.17 / 49.12 2 2
2 7 2007.52 39 14.80 2936 1695 1.87 / 50.82 2 3
3 13 1227.24 18 15.02 1953 528 2.40 / 51.35 2 5
4 13 659.24 18 15.16 1209 330 2.73 / 51.68 2 4
5 13 256.36 18 15.28 651 179 2.91 / 51.86 2 3
6 8 -0.24 165 15.31 274 692 3.60 / 52.55 2 12
Average= 3.50
(KJ/cycle)

Cycle 13 GMT 31/ 3/2023 9:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.16 27 15.27 423 174 0.17 / 45.51 2 2
2 7 2009.04 39 14.80 2931 1692 1.87 / 47.20 2 3
3 13 1246.80 18 15.00 1977 534 2.40 / 47.73 2 3
4 13 657.56 18 15.16 1212 331 2.73 / 48.07 2 4
5 13 295.92 18 15.26 710 195 2.93 / 48.26 2 4
6 8 0.68 165 15.30 273 689 3.61 / 48.95 2 8
Average= 3.50
(KJ/cycle)

Cycle 12 GMT 21/ 3/2023 13:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 27 15.25 421 173 0.17 / 41.84 2 2
2 7 2003.88 38 14.81 2930 1649 1.82 / 43.48 2 3
3 13 1238.64 18 15.02 1968 532 2.35 / 44.02 2 5
4 13 698.28 18 15.15 1266 345 2.70 / 44.36 2 4
5 13 286.96 18 15.27 697 192 2.89 / 44.55 2 4
6 13 15.92 18 15.34 304 84 2.98 / 44.64 2 4
7 8 0.12 165 15.30 276 697 3.67 / 45.33 2 14
Average= 3.49
(KJ/cycle)

Cycle 11 GMT 11/ 3/2023 18:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.08 27 15.28 421 174 0.17 / 38.29 2 2
2 7 2002.08 38 14.81 2928 1648 1.82 / 39.94 2 3
3 13 1213.28 18 15.01 1951 527 2.35 / 40.46 2 5
4 13 674.32 18 15.15 1238 338 2.69 / 40.80 2 5
5 13 223.04 18 15.27 602 165 2.85 / 40.97 2 3
6 8 -0.16 165 15.31 275 695 3.55 / 41.66 2 11
Average= 3.47
(KJ/cycle)

Cycle 10 GMT 1/ 3/2023 22:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 27 15.28 416 172 0.17 / 34.69 2 2
2 7 2003.12 38 14.82 2934 1652 1.82 / 36.34 2 3
3 13 1323.04 18 14.99 2086 563 2.39 / 36.90 2 5
4 13 768.68 18 15.12 1366 372 2.76 / 37.27 2 4
5 13 219.80 18 15.28 591 163 2.92 / 37.44 2 3
6 8 -0.44 165 15.30 269 679 3.60 / 38.12 2 12
Average= 3.47
(KJ/cycle)

Cycle 9 GMT 20/ 2/2023 3:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.12 27 15.26 426 176 0.18 / 31.09 2 2
2 7 2006.12 38 14.81 2936 1652 1.83 / 32.74 2 4
3 13 1274.72 18 15.00 2037 550 2.38 / 33.29 2 6
4 13 661.60 18 15.16 1221 333 2.71 / 33.63 2 4
5 13 294.60 18 15.25 710 195 2.91 / 33.82 2 3
6 8 -0.48 165 15.30 275 694 3.60 / 34.52 2 8
Average= 3.45
(KJ/cycle)

Cycle 8 GMT 10/ 2/2023 8: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 27 15.29 418 173 0.17 / 27.52 2 3
2 7 2002.64 38 14.82 2917 1643 1.82 / 29.16 2 4
3 13 1265.56 18 15.02 1996 540 2.35 / 29.70 2 3
4 13 672.16 18 15.16 1228 335 2.69 / 30.04 2 4
5 13 260.20 18 15.28 661 182 2.87 / 30.22 2 4
6 8 0.52 165 15.31 275 695 3.57 / 30.92 2 12
Average= 3.44
(KJ/cycle)

Cycle 7 GMT 31/ 1/2023 12:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 26 15.29 423 168 0.17 / 23.97 2 3
2 7 2007.60 38 14.83 2937 1655 1.82 / 25.62 2 4
3 13 1224.72 18 15.02 1951 527 2.35 / 26.15 2 5
4 13 683.68 18 15.15 1242 339 2.69 / 26.49 2 4
5 13 230.84 18 15.30 615 169 2.86 / 26.66 2 3
6 8 -0.32 165 15.32 274 693 3.55 / 27.35 2 10
Average= 3.42
(KJ/cycle)

Cycle 6 GMT 21/ 1/2023 17:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 25 15.29 421 161 0.16 / 19.57 2 2
2 10 1026.84 2 15.24 1735 53 0.21 / 19.62 2 3
3 7 2007.76 74 14.71 2927 3186 3.40 / 22.81 2 3
4 13 341.36 18 15.27 775 213 3.61 / 23.02 2 3
5 13 19.68 18 15.35 307 85 3.70 / 23.11 2 3
6 8 0.08 165 15.31 274 692 4.39 / 23.80 2 15
Average= 3.40
(KJ/cycle)

Cycle 5 GMT 11/ 1/2023 20:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 29 15.29 433 192 0.19 / 15.23 2 2
2 3 890.76 -2 15.62 0 0 0.00 / 15.23 2 2
3 3 944.00 -1 15.66 0 0 0.00 / 15.23 2 2
4 7 2005.08 74 14.72 2925 3186 3.38 / 18.41 2 4
5 13 330.16 18 15.27 759 209 3.59 / 18.62 2 3
6 13 16.52 18 15.34 305 84 3.67 / 18.71 2 3
7 8 -0.40 165 15.32 277 700 4.37 / 19.41 2 12
Average= 3.23
(KJ/cycle)

Cycle 4 GMT 1/ 1/2023 22:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 26 15.29 427 170 0.17 / 11.59 2 2
2 7 1524.96 74 14.92 2320 2561 2.73 / 14.15 2 4
3 13 253.48 18 15.30 645 178 2.91 / 14.33 2 3
4 8 -0.44 165 15.33 280 708 3.62 / 15.04 2 10
Average= 3.01
(KJ/cycle)

Cycle 3 GMT 31/12/2022 23:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.72 25 15.29 427 163 0.16 / 7.96 2 2
2 3 1045.92 1 15.25 1809 28 0.19 / 7.99 2 3
3 7 1523.28 74 14.92 2319 2560 2.75 / 10.55 2 5
4 13 249.52 18 15.30 638 176 2.93 / 10.72 2 3
5 8 0.04 165 15.33 276 698 3.63 / 11.42 2 6
Average= 2.85
(KJ/cycle)

Cycle 2 GMT 30/12/2022 23:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 31 15.31 428 203 0.20 / 4.39 2 2
2 3 791.36 -4 15.65 0 0 0.00 / 4.39 2 2
3 3 927.44 -1 15.66 0 0 0.00 / 4.39 2 2
4 7 1513.24 74 14.93 2295 2536 2.74 / 6.92 2 4
5 13 232.52 18 15.32 613 169 2.91 / 7.09 2 3
6 8 0.04 165 15.33 277 701 3.61 / 7.79 2 10
Average= 2.60
(KJ/cycle)

Cycle 1 GMT 30/12/2022 0:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 26 15.51 386 156 0.16 / 1.66 3 3
2 3 942.92 -1 15.65 0 0 0.00 / 1.66 3 3
3 7 984.92 74 15.12 1610 1801 1.96 / 3.46 2 4
4 8 0.04 165 15.36 287 727 2.68 / 4.19 2 15
Average= 2.09
(KJ/cycle)

Cycle 0 GMT 29/12/2022 13:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.96 26 15.62 409 166 0.17 / 0.17 3 3
2 7 130.04 74 15.60 413 477 0.64 / 0.64 3 4
3 8 0.20 240 15.56 230 859 1.50 / 1.50 3 15
Average= 1.50
(KJ/cycle)