SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.52 | 38 | 15.04 | 406 | 232 | 0.23 / 304.75 | 2 | 4 |
2 | 7 | 2006.52 | 38 | 14.73 | 2955 | 1654 | 1.89 / 306.41 | 2 | 8 |
3 | 13 | 1745.88 | 16 | 14.76 | 2636 | 623 | 2.51 / 307.03 | 2 | 11 |
4 | 13 | 1203.52 | 16 | 14.83 | 1949 | 462 | 2.97 / 307.49 | 2 | 13 |
5 | 13 | 635.72 | 16 | 14.95 | 1193 | 285 | 3.26 / 307.78 | 2 | 14 |
6 | 13 | 245.76 | 16 | 15.05 | 641 | 154 | 3.41 / 307.93 | 2 | 13 |
7 | 8 | 0.20 | 165 | 15.09 | 271 | 675 | 4.09 / 308.61 | 2 | 13 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.24 | 38 | 15.05 | 414 | 237 | 0.24 / 300.66 | 2 | 3 |
2 | 7 | 2008.00 | 38 | 14.74 | 2963 | 1660 | 1.90 / 302.32 | 2 | 9 |
3 | 13 | 1702.68 | 16 | 14.77 | 2593 | 613 | 2.51 / 302.93 | 2 | 11 |
4 | 13 | 1258.04 | 16 | 14.82 | 2031 | 482 | 2.99 / 303.41 | 2 | 12 |
5 | 13 | 663.20 | 16 | 14.95 | 1232 | 295 | 3.29 / 303.71 | 2 | 13 |
6 | 13 | 220.80 | 16 | 15.07 | 605 | 146 | 3.43 / 303.85 | 2 | 13 |
7 | 8 | 0.32 | 165 | 15.09 | 268 | 667 | 4.10 / 304.52 | 2 | 18 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.72 | 39 | 15.04 | 410 | 240 | 0.24 / 296.61 | 2 | 4 |
2 | 7 | 2022.80 | 38 | 14.75 | 2973 | 1666 | 1.91 / 298.27 | 2 | 9 |
3 | 13 | 1606.24 | 16 | 14.78 | 2475 | 585 | 2.49 / 298.86 | 2 | 10 |
4 | 13 | 1223.96 | 16 | 14.83 | 1979 | 470 | 2.96 / 299.33 | 2 | 12 |
5 | 13 | 645.16 | 16 | 14.96 | 1203 | 288 | 3.25 / 299.62 | 2 | 13 |
6 | 13 | 205.56 | 16 | 15.09 | 582 | 141 | 3.39 / 299.76 | 2 | 13 |
7 | 8 | 0.08 | 165 | 15.10 | 267 | 665 | 4.06 / 300.42 | 2 | 22 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 121.60 | 38 | 15.05 | 434 | 248 | 0.25 / 292.55 | 2 | 4 |
2 | 7 | 2014.00 | 38 | 14.73 | 2957 | 1655 | 1.90 / 294.20 | 2 | 11 |
3 | 13 | 1652.44 | 16 | 14.77 | 2521 | 596 | 2.50 / 294.80 | 2 | 11 |
4 | 13 | 1209.52 | 16 | 14.83 | 1958 | 465 | 2.96 / 295.26 | 2 | 12 |
5 | 13 | 714.96 | 16 | 14.94 | 1295 | 310 | 3.27 / 295.57 | 2 | 13 |
6 | 13 | 189.16 | 16 | 15.09 | 553 | 134 | 3.41 / 295.70 | 2 | 14 |
7 | 8 | 0.08 | 165 | 15.10 | 266 | 663 | 4.07 / 296.37 | 2 | 17 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.72 | 38 | 15.05 | 434 | 248 | 0.25 / 288.42 | 2 | 4 |
2 | 7 | 2006.84 | 39 | 14.73 | 2960 | 1700 | 1.95 / 290.12 | 2 | 12 |
3 | 13 | 1744.04 | 16 | 14.76 | 2655 | 627 | 2.58 / 290.75 | 2 | 11 |
4 | 13 | 1130.24 | 16 | 14.85 | 1858 | 441 | 3.02 / 291.19 | 2 | 13 |
5 | 13 | 653.52 | 16 | 14.96 | 1213 | 290 | 3.31 / 291.48 | 2 | 14 |
6 | 13 | 211.16 | 16 | 15.09 | 587 | 142 | 3.45 / 291.62 | 2 | 13 |
7 | 8 | 0.00 | 165 | 15.09 | 270 | 672 | 4.12 / 292.30 | 2 | 16 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.36 | 38 | 15.06 | 423 | 242 | 0.24 / 284.33 | 2 | 4 |
2 | 7 | 2005.40 | 39 | 14.75 | 2957 | 1701 | 1.94 / 286.03 | 2 | 8 |
3 | 13 | 1655.00 | 16 | 14.79 | 2539 | 601 | 2.54 / 286.63 | 2 | 10 |
4 | 13 | 1090.80 | 16 | 14.88 | 1785 | 425 | 2.97 / 287.06 | 2 | 12 |
5 | 13 | 700.08 | 16 | 14.96 | 1278 | 306 | 3.27 / 287.37 | 2 | 13 |
6 | 13 | 206.48 | 16 | 15.10 | 577 | 139 | 3.41 / 287.50 | 2 | 13 |
7 | 8 | 0.28 | 165 | 15.11 | 269 | 671 | 4.08 / 288.18 | 2 | 17 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 121.64 | 38 | 15.06 | 428 | 245 | 0.24 / 280.29 | 2 | 3 |
2 | 7 | 2021.84 | 38 | 14.76 | 2970 | 1666 | 1.91 / 281.96 | 2 | 8 |
3 | 13 | 1619.96 | 16 | 14.79 | 2487 | 589 | 2.50 / 282.54 | 2 | 10 |
4 | 13 | 1189.56 | 16 | 14.86 | 1932 | 459 | 2.96 / 283.00 | 2 | 11 |
5 | 13 | 617.84 | 16 | 14.99 | 1162 | 279 | 3.24 / 283.28 | 2 | 12 |
6 | 13 | 194.32 | 16 | 15.11 | 562 | 136 | 3.37 / 283.42 | 2 | 12 |
7 | 8 | -0.08 | 165 | 15.11 | 270 | 673 | 4.05 / 284.09 | 2 | 22 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 38 | 15.07 | 415 | 238 | 0.24 / 276.21 | 2 | 4 |
2 | 7 | 2009.24 | 38 | 14.76 | 2954 | 1657 | 1.89 / 277.86 | 2 | 9 |
3 | 13 | 1669.68 | 16 | 14.79 | 2541 | 601 | 2.50 / 278.46 | 2 | 10 |
4 | 13 | 1195.56 | 16 | 14.84 | 1943 | 461 | 2.96 / 278.92 | 2 | 12 |
5 | 13 | 674.16 | 16 | 14.97 | 1244 | 298 | 3.26 / 279.22 | 2 | 13 |
6 | 13 | 230.68 | 16 | 15.10 | 615 | 149 | 3.40 / 279.37 | 2 | 13 |
7 | 8 | 0.00 | 165 | 15.11 | 270 | 673 | 4.08 / 280.04 | 2 | 22 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.56 | 38 | 15.07 | 431 | 247 | 0.25 / 272.14 | 2 | 4 |
2 | 7 | 2015.60 | 38 | 14.77 | 2967 | 1665 | 1.91 / 273.80 | 2 | 8 |
3 | 13 | 1682.16 | 16 | 14.81 | 2569 | 609 | 2.52 / 274.41 | 2 | 10 |
4 | 13 | 1204.24 | 16 | 14.87 | 1951 | 464 | 2.99 / 274.87 | 2 | 11 |
5 | 13 | 580.76 | 16 | 15.01 | 1114 | 268 | 3.25 / 275.14 | 2 | 14 |
6 | 13 | 239.76 | 16 | 15.12 | 628 | 152 | 3.40 / 275.29 | 2 | 13 |
7 | 8 | 0.08 | 165 | 15.13 | 270 | 674 | 4.08 / 275.97 | 2 | 13 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.80 | 38 | 15.09 | 428 | 245 | 0.25 / 268.07 | 2 | 3 |
2 | 7 | 2019.12 | 38 | 14.74 | 2983 | 1671 | 1.92 / 269.74 | 2 | 8 |
3 | 13 | 1592.28 | 16 | 14.79 | 2464 | 583 | 2.50 / 270.33 | 2 | 13 |
4 | 13 | 1220.08 | 16 | 14.83 | 1983 | 471 | 2.97 / 270.80 | 2 | 12 |
5 | 13 | 588.64 | 16 | 14.99 | 1125 | 270 | 3.24 / 271.07 | 2 | 13 |
6 | 13 | 237.80 | 16 | 15.09 | 625 | 151 | 3.39 / 271.22 | 2 | 13 |
7 | 8 | 0.16 | 165 | 15.10 | 270 | 673 | 4.06 / 271.89 | 2 | 19 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.28 | 38 | 15.07 | 428 | 245 | 0.25 / 264.00 | 2 | 3 |
2 | 7 | 2020.44 | 38 | 14.78 | 2979 | 1673 | 1.92 / 265.67 | 2 | 9 |
3 | 13 | 1631.36 | 16 | 14.82 | 2518 | 597 | 2.52 / 266.27 | 2 | 10 |
4 | 13 | 1199.76 | 16 | 14.87 | 1951 | 464 | 2.98 / 266.73 | 2 | 14 |
5 | 13 | 593.96 | 16 | 15.02 | 1136 | 273 | 3.25 / 267.01 | 2 | 14 |
6 | 13 | 209.32 | 16 | 15.13 | 587 | 142 | 3.39 / 267.15 | 2 | 13 |
7 | 8 | 0.16 | 165 | 15.14 | 271 | 677 | 4.07 / 267.83 | 2 | 20 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 38 | 15.08 | 408 | 234 | 0.23 / 259.87 | 2 | 4 |
2 | 7 | 2008.16 | 38 | 14.76 | 2953 | 1656 | 1.89 / 261.53 | 2 | 8 |
3 | 13 | 1710.20 | 16 | 14.79 | 2603 | 616 | 2.51 / 262.14 | 2 | 11 |
4 | 13 | 1250.08 | 16 | 14.85 | 2006 | 477 | 2.98 / 262.62 | 2 | 14 |
5 | 13 | 754.92 | 16 | 14.97 | 1351 | 324 | 3.31 / 262.94 | 2 | 12 |
6 | 13 | 210.76 | 16 | 15.12 | 585 | 142 | 3.45 / 263.08 | 2 | 12 |
7 | 8 | -0.08 | 165 | 15.12 | 269 | 671 | 4.12 / 263.75 | 2 | 20 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.00 | 38 | 15.07 | 434 | 249 | 0.25 / 255.83 | 2 | 4 |
2 | 7 | 2013.60 | 38 | 14.77 | 2968 | 1666 | 1.91 / 257.50 | 2 | 9 |
3 | 13 | 1698.28 | 16 | 14.81 | 2591 | 614 | 2.53 / 258.11 | 2 | 11 |
4 | 13 | 1055.64 | 16 | 14.91 | 1761 | 420 | 2.95 / 258.53 | 2 | 14 |
5 | 13 | 647.36 | 16 | 15.03 | 1210 | 291 | 3.24 / 258.82 | 2 | 13 |
6 | 13 | 207.68 | 16 | 15.15 | 584 | 142 | 3.38 / 258.97 | 2 | 14 |
7 | 8 | -0.24 | 165 | 15.14 | 268 | 669 | 4.05 / 259.64 | 2 | 20 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 38 | 15.10 | 399 | 229 | 0.23 / 251.74 | 2 | 3 |
2 | 7 | 2007.00 | 38 | 14.75 | 2957 | 1657 | 1.89 / 253.39 | 2 | 7 |
3 | 13 | 1645.36 | 16 | 14.80 | 2517 | 596 | 2.48 / 253.99 | 2 | 15 |
4 | 13 | 1176.16 | 16 | 14.87 | 1914 | 455 | 2.94 / 254.44 | 2 | 12 |
5 | 13 | 739.16 | 16 | 14.97 | 1329 | 318 | 3.26 / 254.76 | 2 | 13 |
6 | 13 | 232.96 | 16 | 15.11 | 614 | 148 | 3.40 / 254.91 | 2 | 13 |
7 | 8 | 0.16 | 165 | 15.13 | 270 | 674 | 4.08 / 255.58 | 2 | 20 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 121.68 | 38 | 15.09 | 426 | 244 | 0.24 / 247.68 | 2 | 4 |
2 | 7 | 2006.44 | 38 | 14.76 | 2955 | 1657 | 1.90 / 249.34 | 2 | 11 |
3 | 13 | 1608.84 | 16 | 14.83 | 2471 | 586 | 2.49 / 249.92 | 2 | 11 |
4 | 13 | 1274.60 | 16 | 14.86 | 2046 | 486 | 2.97 / 250.41 | 2 | 13 |
5 | 13 | 625.88 | 16 | 15.03 | 1172 | 282 | 3.26 / 250.69 | 2 | 14 |
6 | 13 | 233.52 | 16 | 15.13 | 611 | 148 | 3.40 / 250.84 | 2 | 12 |
7 | 8 | 0.20 | 165 | 15.15 | 267 | 667 | 4.07 / 251.51 | 2 | 19 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 38 | 15.09 | 395 | 227 | 0.23 / 243.57 | 2 | 3 |
2 | 7 | 2009.04 | 39 | 14.76 | 2960 | 1704 | 1.93 / 245.27 | 2 | 13 |
3 | 13 | 1694.12 | 16 | 14.81 | 2575 | 610 | 2.54 / 245.88 | 2 | 10 |
4 | 13 | 1132.52 | 16 | 14.89 | 1854 | 442 | 2.98 / 246.33 | 2 | 14 |
5 | 13 | 658.28 | 16 | 15.02 | 1214 | 292 | 3.27 / 246.62 | 2 | 13 |
6 | 13 | 222.44 | 16 | 15.14 | 602 | 146 | 3.42 / 246.76 | 2 | 12 |
7 | 8 | 0.24 | 165 | 15.16 | 268 | 670 | 4.09 / 247.43 | 2 | 16 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.40 | 38 | 15.10 | 400 | 230 | 0.23 / 239.51 | 2 | 3 |
2 | 7 | 2010.52 | 38 | 14.77 | 2954 | 1658 | 1.89 / 241.17 | 2 | 10 |
3 | 13 | 1624.48 | 16 | 14.83 | 2494 | 592 | 2.48 / 241.76 | 2 | 11 |
4 | 13 | 1235.36 | 16 | 14.88 | 1993 | 474 | 2.95 / 242.23 | 2 | 12 |
5 | 13 | 644.00 | 16 | 15.04 | 1203 | 289 | 3.24 / 242.52 | 2 | 13 |
6 | 13 | 236.40 | 16 | 15.13 | 623 | 151 | 3.39 / 242.67 | 2 | 13 |
7 | 8 | 0.08 | 165 | 15.15 | 269 | 672 | 4.07 / 243.34 | 2 | 24 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 38 | 15.11 | 403 | 231 | 0.23 / 235.41 | 2 | 3 |
2 | 7 | 2005.84 | 38 | 14.77 | 2957 | 1660 | 1.89 / 237.07 | 2 | 9 |
3 | 13 | 1729.80 | 16 | 14.81 | 2643 | 626 | 2.52 / 237.70 | 2 | 10 |
4 | 13 | 1206.92 | 16 | 14.89 | 1960 | 467 | 2.98 / 238.16 | 2 | 13 |
5 | 13 | 673.40 | 16 | 15.01 | 1242 | 298 | 3.28 / 238.46 | 2 | 13 |
6 | 13 | 212.80 | 16 | 15.15 | 590 | 143 | 3.43 / 238.61 | 2 | 14 |
7 | 8 | 0.24 | 165 | 15.16 | 269 | 673 | 4.10 / 239.28 | 2 | 19 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 38 | 15.12 | 407 | 234 | 0.23 / 231.35 | 2 | 3 |
2 | 7 | 2008.60 | 38 | 14.77 | 2975 | 1670 | 1.90 / 233.02 | 2 | 10 |
3 | 13 | 1691.84 | 16 | 14.83 | 2597 | 616 | 2.52 / 233.63 | 2 | 11 |
4 | 13 | 1148.92 | 16 | 14.91 | 1887 | 450 | 2.97 / 234.08 | 2 | 14 |
5 | 13 | 654.60 | 16 | 15.03 | 1218 | 293 | 3.26 / 234.37 | 2 | 14 |
6 | 13 | 195.36 | 16 | 15.16 | 565 | 137 | 3.40 / 234.51 | 2 | 13 |
7 | 8 | 0.52 | 165 | 15.16 | 267 | 668 | 4.07 / 235.18 | 2 | 14 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 38 | 15.11 | 396 | 227 | 0.23 / 227.26 | 2 | 3 |
2 | 7 | 2010.48 | 38 | 14.77 | 2970 | 1667 | 1.89 / 228.93 | 2 | 9 |
3 | 13 | 1691.72 | 16 | 14.83 | 2593 | 615 | 2.51 / 229.54 | 2 | 10 |
4 | 13 | 1227.60 | 16 | 14.89 | 1993 | 475 | 2.98 / 230.02 | 2 | 12 |
5 | 13 | 642.00 | 16 | 15.04 | 1202 | 289 | 3.27 / 230.31 | 2 | 13 |
6 | 13 | 194.24 | 16 | 15.16 | 563 | 137 | 3.41 / 230.44 | 2 | 13 |
7 | 8 | 0.52 | 165 | 15.16 | 267 | 668 | 4.08 / 231.11 | 2 | 20 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.52 | 38 | 15.11 | 426 | 245 | 0.24 / 223.18 | 2 | 4 |
2 | 7 | 2025.68 | 39 | 14.78 | 3002 | 1730 | 1.98 / 224.92 | 2 | 14 |
3 | 13 | 1660.56 | 16 | 14.82 | 2557 | 606 | 2.58 / 225.52 | 2 | 11 |
4 | 13 | 1077.16 | 16 | 14.93 | 1797 | 429 | 3.01 / 225.95 | 2 | 15 |
5 | 13 | 616.76 | 16 | 15.07 | 1167 | 281 | 3.29 / 226.23 | 2 | 14 |
6 | 13 | 177.04 | 16 | 15.18 | 538 | 131 | 3.42 / 226.36 | 2 | 12 |
7 | 8 | -0.04 | 165 | 15.17 | 268 | 671 | 4.09 / 227.03 | 2 | 17 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 38 | 15.12 | 401 | 230 | 0.23 / 219.07 | 2 | 3 |
2 | 7 | 2014.00 | 38 | 14.78 | 2975 | 1671 | 1.90 / 220.74 | 2 | 12 |
3 | 13 | 1746.28 | 16 | 14.81 | 2659 | 630 | 2.53 / 221.37 | 2 | 10 |
4 | 13 | 1192.44 | 16 | 14.91 | 1946 | 464 | 3.00 / 221.83 | 2 | 14 |
5 | 13 | 661.08 | 16 | 15.05 | 1232 | 297 | 3.29 / 222.13 | 2 | 14 |
6 | 13 | 201.40 | 16 | 15.17 | 572 | 139 | 3.43 / 222.27 | 2 | 13 |
7 | 8 | 0.24 | 165 | 15.17 | 269 | 673 | 4.10 / 222.94 | 2 | 21 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.92 | 38 | 15.12 | 396 | 228 | 0.23 / 214.95 | 2 | 3 |
2 | 7 | 2009.68 | 39 | 14.80 | 2957 | 1707 | 1.93 / 216.65 | 2 | 9 |
3 | 13 | 1682.20 | 16 | 14.83 | 2566 | 609 | 2.54 / 217.26 | 2 | 13 |
4 | 13 | 1164.40 | 16 | 14.92 | 1896 | 453 | 3.00 / 217.71 | 2 | 14 |
5 | 13 | 680.00 | 16 | 15.03 | 1245 | 299 | 3.30 / 218.01 | 2 | 12 |
6 | 13 | 220.12 | 16 | 15.16 | 606 | 147 | 3.44 / 218.16 | 2 | 13 |
7 | 8 | 0.40 | 165 | 15.16 | 270 | 675 | 4.12 / 218.84 | 2 | 21 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 121.08 | 38 | 15.14 | 434 | 250 | 0.25 / 210.88 | 2 | 3 |
2 | 7 | 2008.64 | 38 | 14.79 | 2957 | 1662 | 1.91 / 212.54 | 2 | 8 |
3 | 13 | 1653.36 | 16 | 14.85 | 2530 | 601 | 2.51 / 213.14 | 2 | 11 |
4 | 13 | 1222.28 | 16 | 14.90 | 1971 | 470 | 2.98 / 213.61 | 2 | 15 |
5 | 13 | 630.28 | 16 | 15.06 | 1188 | 286 | 3.27 / 213.89 | 2 | 14 |
6 | 13 | 231.72 | 16 | 15.18 | 618 | 150 | 3.42 / 214.04 | 2 | 13 |
7 | 8 | -0.04 | 165 | 15.18 | 269 | 674 | 4.09 / 214.72 | 2 | 20 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 38 | 15.13 | 408 | 235 | 0.23 / 206.84 | 2 | 4 |
2 | 7 | 2010.12 | 38 | 14.79 | 2965 | 1666 | 1.90 / 208.51 | 2 | 10 |
3 | 13 | 1599.28 | 16 | 14.87 | 2467 | 587 | 2.49 / 209.10 | 2 | 11 |
4 | 13 | 1141.80 | 16 | 14.94 | 1867 | 446 | 2.93 / 209.54 | 2 | 15 |
5 | 13 | 615.04 | 16 | 15.07 | 1162 | 280 | 3.21 / 209.82 | 2 | 13 |
6 | 13 | 186.04 | 16 | 15.18 | 550 | 134 | 3.35 / 209.96 | 2 | 12 |
7 | 8 | -0.04 | 165 | 15.19 | 267 | 669 | 4.02 / 210.63 | 2 | 16 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 38 | 15.14 | 408 | 235 | 0.23 / 202.80 | 2 | 3 |
2 | 7 | 2015.68 | 38 | 14.79 | 2970 | 1669 | 1.90 / 204.46 | 2 | 12 |
3 | 13 | 1635.60 | 16 | 14.85 | 2514 | 597 | 2.50 / 205.06 | 2 | 12 |
4 | 13 | 1087.44 | 16 | 14.95 | 1800 | 431 | 2.93 / 205.49 | 2 | 14 |
5 | 13 | 702.28 | 16 | 15.05 | 1282 | 309 | 3.24 / 205.80 | 2 | 12 |
6 | 13 | 198.56 | 16 | 15.18 | 568 | 138 | 3.38 / 205.94 | 2 | 12 |
7 | 8 | 0.16 | 165 | 15.18 | 267 | 669 | 4.05 / 206.61 | 2 | 14 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.84 | 38 | 15.14 | 404 | 232 | 0.23 / 198.66 | 2 | 3 |
2 | 7 | 2023.64 | 38 | 14.80 | 2997 | 1686 | 1.92 / 200.35 | 2 | 16 |
3 | 13 | 1716.40 | 16 | 14.84 | 2629 | 624 | 2.54 / 200.97 | 2 | 12 |
4 | 13 | 1273.76 | 16 | 14.91 | 2060 | 491 | 3.03 / 201.46 | 2 | 12 |
5 | 13 | 645.56 | 16 | 15.07 | 1205 | 291 | 3.32 / 201.75 | 2 | 13 |
6 | 13 | 200.56 | 16 | 15.19 | 573 | 139 | 3.46 / 201.89 | 2 | 14 |
7 | 8 | -0.36 | 165 | 15.19 | 267 | 669 | 4.13 / 202.56 | 2 | 19 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 38 | 15.14 | 409 | 235 | 0.24 / 194.59 | 2 | 4 |
2 | 7 | 2022.64 | 38 | 14.80 | 2979 | 1675 | 1.91 / 196.26 | 2 | 8 |
3 | 13 | 1705.64 | 16 | 14.84 | 2597 | 617 | 2.53 / 196.88 | 2 | 11 |
4 | 13 | 1186.52 | 16 | 14.92 | 1929 | 460 | 2.99 / 197.34 | 2 | 14 |
5 | 13 | 622.32 | 16 | 15.07 | 1169 | 282 | 3.27 / 197.62 | 2 | 13 |
6 | 13 | 192.32 | 16 | 15.19 | 559 | 136 | 3.41 / 197.76 | 2 | 13 |
7 | 8 | 0.04 | 165 | 15.19 | 268 | 672 | 4.08 / 198.43 | 2 | 23 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.92 | 38 | 15.15 | 426 | 245 | 0.25 / 190.46 | 2 | 4 |
2 | 3 | 1018.12 | 1 | 15.21 | 1783 | 27 | 0.27 / 190.49 | 2 | 9 |
3 | 7 | 2023.08 | 38 | 14.81 | 2983 | 1679 | 1.95 / 192.17 | 2 | 10 |
4 | 13 | 1662.72 | 16 | 14.88 | 2551 | 607 | 2.56 / 192.77 | 2 | 11 |
5 | 13 | 1147.12 | 16 | 14.96 | 1867 | 447 | 3.01 / 193.22 | 2 | 13 |
6 | 13 | 737.84 | 16 | 15.05 | 1332 | 321 | 3.33 / 193.54 | 2 | 14 |
7 | 13 | 185.80 | 16 | 15.19 | 549 | 133 | 3.46 / 193.67 | 2 | 12 |
8 | 8 | -0.20 | 165 | 15.21 | 270 | 678 | 4.14 / 194.35 | 2 | 20 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 38 | 15.15 | 413 | 238 | 0.24 / 186.36 | 2 | 4 |
2 | 7 | 2011.40 | 38 | 14.83 | 2972 | 1675 | 1.91 / 188.03 | 2 | 14 |
3 | 13 | 1695.96 | 16 | 14.87 | 2601 | 619 | 2.53 / 188.65 | 2 | 10 |
4 | 13 | 1193.68 | 16 | 14.94 | 1953 | 467 | 3.00 / 189.12 | 2 | 13 |
5 | 13 | 596.20 | 16 | 15.10 | 1135 | 274 | 3.27 / 189.39 | 2 | 14 |
6 | 13 | 194.12 | 16 | 15.21 | 562 | 137 | 3.41 / 189.53 | 2 | 11 |
7 | 8 | -0.12 | 165 | 15.21 | 272 | 683 | 4.09 / 190.21 | 2 | 19 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 38 | 15.17 | 407 | 235 | 0.23 / 182.28 | 2 | 4 |
2 | 7 | 2005.92 | 38 | 14.80 | 2976 | 1674 | 1.91 / 183.95 | 2 | 8 |
3 | 13 | 1682.52 | 16 | 14.86 | 2583 | 614 | 2.52 / 184.56 | 2 | 14 |
4 | 13 | 1148.40 | 16 | 14.96 | 1896 | 454 | 2.98 / 185.02 | 2 | 12 |
5 | 13 | 654.44 | 16 | 15.07 | 1223 | 295 | 3.27 / 185.31 | 2 | 13 |
6 | 13 | 159.52 | 16 | 15.20 | 512 | 125 | 3.40 / 185.44 | 2 | 12 |
7 | 8 | 0.08 | 165 | 15.20 | 273 | 685 | 4.08 / 186.12 | 2 | 15 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 38 | 15.15 | 411 | 237 | 0.24 / 178.20 | 2 | 4 |
2 | 7 | 2006.08 | 38 | 14.83 | 2959 | 1668 | 1.90 / 179.87 | 2 | 7 |
3 | 13 | 1697.16 | 16 | 14.88 | 2598 | 619 | 2.52 / 180.48 | 2 | 12 |
4 | 13 | 1088.00 | 16 | 15.00 | 1810 | 434 | 2.96 / 180.92 | 2 | 13 |
5 | 13 | 658.36 | 16 | 15.10 | 1226 | 296 | 3.25 / 181.22 | 2 | 14 |
6 | 13 | 201.76 | 16 | 15.22 | 577 | 141 | 3.39 / 181.36 | 2 | 12 |
7 | 8 | 0.56 | 165 | 15.23 | 273 | 686 | 4.08 / 182.04 | 2 | 21 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.44 | 38 | 15.17 | 407 | 235 | 0.23 / 174.15 | 2 | 3 |
2 | 7 | 2006.56 | 38 | 14.83 | 2954 | 1665 | 1.90 / 175.81 | 2 | 10 |
3 | 13 | 1587.76 | 16 | 14.90 | 2451 | 584 | 2.48 / 176.40 | 2 | 11 |
4 | 13 | 1165.36 | 16 | 14.97 | 1913 | 458 | 2.94 / 176.86 | 2 | 13 |
5 | 13 | 639.04 | 16 | 15.09 | 1200 | 290 | 3.23 / 177.15 | 2 | 13 |
6 | 13 | 180.36 | 16 | 15.22 | 546 | 133 | 3.36 / 177.28 | 2 | 14 |
7 | 8 | 0.16 | 165 | 15.21 | 272 | 683 | 4.05 / 177.96 | 2 | 19 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 38 | 15.16 | 411 | 237 | 0.24 / 169.94 | 2 | 5 |
2 | 7 | 2018.76 | 38 | 14.83 | 2996 | 1688 | 1.93 / 171.63 | 2 | 13 |
3 | 13 | 1649.40 | 18 | 14.89 | 2544 | 682 | 2.61 / 172.31 | 2 | 14 |
4 | 13 | 1068.72 | 18 | 14.99 | 1789 | 483 | 3.09 / 172.80 | 2 | 14 |
5 | 13 | 599.72 | 18 | 15.11 | 1147 | 312 | 3.40 / 173.11 | 2 | 13 |
6 | 13 | 106.60 | 18 | 15.23 | 437 | 120 | 3.52 / 173.23 | 2 | 10 |
7 | 8 | 0.04 | 165 | 15.23 | 273 | 686 | 4.21 / 173.91 | 2 | 19 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 38 | 15.15 | 414 | 238 | 0.24 / 165.84 | 2 | 3 |
2 | 7 | 2008.08 | 38 | 14.82 | 2981 | 1679 | 1.92 / 167.52 | 2 | 10 |
3 | 13 | 1660.04 | 18 | 14.86 | 2549 | 682 | 2.60 / 168.20 | 2 | 11 |
4 | 13 | 1071.76 | 18 | 14.97 | 1781 | 480 | 3.08 / 168.68 | 2 | 12 |
5 | 13 | 445.52 | 18 | 15.14 | 924 | 252 | 3.33 / 168.93 | 2 | 13 |
6 | 13 | 52.04 | 18 | 15.25 | 349 | 96 | 3.43 / 169.03 | 2 | 13 |
7 | 8 | 0.56 | 165 | 15.20 | 271 | 680 | 4.11 / 169.71 | 2 | 21 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.60 | 38 | 15.16 | 433 | 249 | 0.25 / 161.74 | 2 | 3 |
2 | 7 | 2007.56 | 38 | 14.83 | 2975 | 1677 | 1.93 / 163.42 | 2 | 9 |
3 | 13 | 1573.68 | 18 | 14.89 | 2443 | 655 | 2.58 / 164.07 | 2 | 15 |
4 | 13 | 1047.36 | 18 | 14.97 | 1745 | 470 | 3.05 / 164.54 | 2 | 13 |
5 | 13 | 500.88 | 18 | 15.12 | 1000 | 272 | 3.32 / 164.81 | 2 | 14 |
6 | 13 | 85.04 | 18 | 15.22 | 399 | 109 | 3.43 / 164.92 | 2 | 10 |
7 | 8 | 0.04 | 165 | 15.20 | 271 | 680 | 4.11 / 165.60 | 2 | 24 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.08 | 38 | 15.15 | 407 | 234 | 0.23 / 157.68 | 2 | 4 |
2 | 7 | 2006.20 | 38 | 14.85 | 2977 | 1680 | 1.91 / 159.36 | 2 | 10 |
3 | 13 | 1585.96 | 18 | 14.89 | 2467 | 661 | 2.58 / 160.02 | 2 | 12 |
4 | 13 | 1032.48 | 18 | 15.00 | 1733 | 468 | 3.04 / 160.49 | 2 | 13 |
5 | 13 | 420.68 | 18 | 15.15 | 883 | 241 | 3.28 / 160.73 | 2 | 13 |
6 | 13 | 39.28 | 18 | 15.25 | 328 | 90 | 3.37 / 160.82 | 2 | 13 |
7 | 8 | 0.24 | 165 | 15.21 | 268 | 673 | 4.05 / 161.49 | 2 | 14 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.76 | 38 | 15.16 | 428 | 247 | 0.25 / 153.51 | 2 | 4 |
2 | 7 | 2022.56 | 38 | 14.81 | 2990 | 1683 | 1.93 / 155.19 | 2 | 10 |
3 | 13 | 1695.76 | 18 | 14.85 | 2599 | 695 | 2.62 / 155.89 | 2 | 10 |
4 | 13 | 1104.48 | 18 | 14.97 | 1823 | 491 | 3.12 / 156.38 | 2 | 13 |
5 | 13 | 511.12 | 18 | 15.12 | 1014 | 276 | 3.39 / 156.66 | 2 | 12 |
6 | 13 | 98.88 | 18 | 15.22 | 417 | 114 | 3.51 / 156.77 | 2 | 13 |
7 | 8 | -0.20 | 165 | 15.21 | 268 | 673 | 4.18 / 157.44 | 2 | 11 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.80 | 38 | 15.18 | 423 | 244 | 0.24 / 149.30 | 2 | 3 |
2 | 7 | 2009.12 | 39 | 14.82 | 2977 | 1721 | 1.96 / 151.02 | 2 | 10 |
3 | 13 | 1704.28 | 18 | 14.87 | 2603 | 697 | 2.66 / 151.71 | 2 | 10 |
4 | 13 | 1174.04 | 18 | 14.97 | 1919 | 517 | 3.18 / 152.23 | 2 | 12 |
5 | 13 | 460.40 | 18 | 15.15 | 943 | 257 | 3.44 / 152.49 | 2 | 13 |
6 | 13 | 62.48 | 18 | 15.24 | 363 | 100 | 3.54 / 152.59 | 2 | 10 |
7 | 8 | 0.00 | 165 | 15.22 | 269 | 676 | 4.21 / 153.26 | 2 | 19 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.68 | 38 | 15.17 | 414 | 239 | 0.24 / 145.21 | 2 | 4 |
2 | 7 | 2005.88 | 38 | 14.82 | 2964 | 1669 | 1.91 / 146.87 | 2 | 9 |
3 | 13 | 1684.24 | 18 | 14.86 | 2575 | 689 | 2.60 / 147.56 | 2 | 11 |
4 | 13 | 1084.36 | 18 | 14.98 | 1803 | 486 | 3.08 / 148.05 | 2 | 13 |
5 | 13 | 427.64 | 18 | 15.16 | 887 | 242 | 3.32 / 148.29 | 2 | 13 |
6 | 13 | 43.60 | 18 | 15.26 | 332 | 91 | 3.42 / 148.38 | 2 | 8 |
7 | 8 | 0.32 | 165 | 15.23 | 267 | 671 | 4.09 / 149.05 | 2 | 13 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.28 | 37 | 15.17 | 425 | 239 | 0.24 / 141.01 | 2 | 3 |
2 | 7 | 2022.56 | 38 | 14.84 | 2975 | 1678 | 1.92 / 142.68 | 2 | 10 |
3 | 13 | 1690.40 | 18 | 14.88 | 2584 | 692 | 2.61 / 143.38 | 2 | 10 |
4 | 13 | 1094.84 | 18 | 14.99 | 1815 | 490 | 3.10 / 143.87 | 2 | 12 |
5 | 13 | 580.72 | 18 | 15.11 | 1112 | 302 | 3.40 / 144.17 | 2 | 13 |
6 | 13 | 106.08 | 18 | 15.24 | 429 | 118 | 3.52 / 144.29 | 2 | 10 |
7 | 8 | -0.28 | 165 | 15.23 | 271 | 681 | 4.20 / 144.97 | 2 | 19 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 37 | 15.18 | 403 | 226 | 0.23 / 136.93 | 2 | 4 |
2 | 7 | 2008.16 | 38 | 14.84 | 2973 | 1677 | 1.90 / 138.60 | 2 | 9 |
3 | 13 | 1599.24 | 18 | 14.90 | 2469 | 662 | 2.57 / 139.27 | 2 | 11 |
4 | 13 | 988.88 | 18 | 15.02 | 1679 | 454 | 3.02 / 139.72 | 2 | 11 |
5 | 13 | 453.92 | 18 | 15.15 | 934 | 255 | 3.27 / 139.97 | 2 | 12 |
6 | 13 | 90.32 | 18 | 15.26 | 408 | 112 | 3.39 / 140.09 | 2 | 9 |
7 | 8 | -0.36 | 165 | 15.22 | 271 | 681 | 4.07 / 140.77 | 2 | 20 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 37 | 15.18 | 419 | 235 | 0.24 / 132.79 | 2 | 3 |
2 | 7 | 2008.40 | 39 | 14.85 | 2967 | 1718 | 1.95 / 134.51 | 2 | 10 |
3 | 13 | 1565.20 | 18 | 14.91 | 2423 | 650 | 2.60 / 135.16 | 2 | 11 |
4 | 13 | 1087.80 | 18 | 15.00 | 1798 | 485 | 3.09 / 135.64 | 2 | 14 |
5 | 13 | 486.84 | 18 | 15.15 | 982 | 268 | 3.36 / 135.91 | 2 | 12 |
6 | 13 | 78.04 | 18 | 15.25 | 388 | 107 | 3.46 / 136.02 | 2 | 11 |
7 | 8 | -0.12 | 165 | 15.23 | 272 | 684 | 4.15 / 136.70 | 2 | 18 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 37 | 15.19 | 411 | 231 | 0.23 / 128.62 | 2 | 3 |
2 | 7 | 2017.96 | 38 | 14.85 | 2991 | 1688 | 1.92 / 130.31 | 2 | 9 |
3 | 13 | 1696.20 | 18 | 14.90 | 2597 | 697 | 2.62 / 131.00 | 2 | 13 |
4 | 13 | 1132.56 | 18 | 14.99 | 1866 | 503 | 3.12 / 131.51 | 2 | 15 |
5 | 13 | 476.48 | 18 | 15.16 | 972 | 265 | 3.38 / 131.77 | 2 | 13 |
6 | 13 | 72.96 | 18 | 15.26 | 379 | 104 | 3.49 / 131.88 | 2 | 11 |
7 | 8 | 0.44 | 165 | 15.24 | 269 | 676 | 4.16 / 132.55 | 2 | 20 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 37 | 15.20 | 407 | 229 | 0.23 / 124.50 | 2 | 3 |
2 | 7 | 2007.04 | 38 | 14.86 | 2964 | 1674 | 1.90 / 126.18 | 2 | 10 |
3 | 13 | 1605.84 | 18 | 14.92 | 2481 | 666 | 2.57 / 126.84 | 2 | 11 |
4 | 13 | 1091.44 | 18 | 15.02 | 1807 | 489 | 3.06 / 127.33 | 2 | 12 |
5 | 13 | 508.08 | 18 | 15.16 | 1011 | 276 | 3.33 / 127.61 | 2 | 13 |
6 | 13 | 60.00 | 18 | 15.27 | 362 | 99 | 3.43 / 127.71 | 2 | 12 |
7 | 8 | -0.20 | 165 | 15.24 | 272 | 684 | 4.12 / 128.39 | 2 | 19 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.20 | 37 | 15.19 | 434 | 244 | 0.24 / 120.40 | 2 | 4 |
2 | 7 | 2006.92 | 38 | 14.86 | 2978 | 1682 | 1.93 / 122.08 | 2 | 9 |
3 | 13 | 1615.56 | 18 | 14.91 | 2501 | 671 | 2.60 / 122.75 | 2 | 16 |
4 | 13 | 1083.52 | 18 | 15.01 | 1801 | 487 | 3.08 / 123.24 | 2 | 12 |
5 | 13 | 457.68 | 18 | 15.18 | 939 | 257 | 3.34 / 123.49 | 2 | 12 |
6 | 13 | 51.24 | 18 | 15.27 | 349 | 96 | 3.44 / 123.59 | 2 | 10 |
7 | 8 | 0.04 | 165 | 15.24 | 272 | 684 | 4.12 / 124.27 | 2 | 19 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.16 | 37 | 15.17 | 408 | 229 | 0.23 / 116.24 | 2 | 4 |
2 | 7 | 2008.76 | 38 | 14.85 | 2958 | 1669 | 1.90 / 117.91 | 2 | 7 |
3 | 13 | 1684.48 | 18 | 14.90 | 2577 | 691 | 2.59 / 118.60 | 2 | 13 |
4 | 13 | 1109.04 | 18 | 14.99 | 1826 | 493 | 3.08 / 119.09 | 2 | 11 |
5 | 13 | 513.40 | 18 | 15.13 | 1020 | 278 | 3.36 / 119.37 | 2 | 12 |
6 | 13 | 64.76 | 18 | 15.26 | 367 | 101 | 3.46 / 119.47 | 2 | 10 |
7 | 8 | -0.04 | 165 | 15.24 | 271 | 681 | 4.14 / 120.15 | 2 | 22 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 37 | 15.21 | 411 | 231 | 0.23 / 112.05 | 2 | 3 |
2 | 7 | 2023.92 | 39 | 14.84 | 2989 | 1730 | 1.96 / 113.78 | 2 | 10 |
3 | 13 | 1599.00 | 18 | 14.91 | 2469 | 663 | 2.62 / 114.44 | 2 | 12 |
4 | 13 | 1128.88 | 18 | 14.97 | 1856 | 500 | 3.12 / 114.94 | 2 | 13 |
5 | 13 | 517.08 | 18 | 15.14 | 1027 | 280 | 3.40 / 115.22 | 2 | 14 |
6 | 13 | 59.00 | 18 | 15.25 | 361 | 99 | 3.50 / 115.32 | 2 | 10 |
7 | 8 | 0.12 | 165 | 15.23 | 274 | 689 | 4.19 / 116.01 | 2 | 15 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.72 | 37 | 15.20 | 433 | 244 | 0.24 / 107.99 | 2 | 4 |
2 | 7 | 2006.24 | 38 | 14.87 | 2953 | 1669 | 1.91 / 109.66 | 2 | 10 |
3 | 13 | 1559.08 | 18 | 14.93 | 2411 | 648 | 2.56 / 110.31 | 2 | 16 |
4 | 13 | 1042.56 | 18 | 15.05 | 1737 | 471 | 3.03 / 110.78 | 2 | 13 |
5 | 13 | 491.12 | 18 | 15.18 | 988 | 270 | 3.30 / 111.05 | 2 | 14 |
6 | 13 | 38.60 | 18 | 15.28 | 329 | 90 | 3.39 / 111.14 | 2 | 8 |
7 | 8 | 0.88 | 165 | 15.26 | 271 | 682 | 4.07 / 111.82 | 2 | 23 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 37 | 15.20 | 398 | 224 | 0.22 / 103.87 | 2 | 3 |
2 | 7 | 2021.00 | 38 | 14.87 | 2987 | 1688 | 1.91 / 105.55 | 2 | 7 |
3 | 13 | 1653.52 | 18 | 14.92 | 2545 | 683 | 2.60 / 106.24 | 2 | 17 |
4 | 13 | 1034.28 | 18 | 15.05 | 1742 | 472 | 3.07 / 106.71 | 2 | 11 |
5 | 13 | 421.52 | 18 | 15.20 | 892 | 244 | 3.31 / 106.95 | 2 | 12 |
6 | 13 | 70.64 | 18 | 15.27 | 381 | 105 | 3.42 / 107.06 | 2 | 10 |
7 | 8 | 0.24 | 165 | 15.25 | 273 | 687 | 4.10 / 107.75 | 2 | 20 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.12 | 37 | 15.21 | 424 | 239 | 0.24 / 99.74 | 2 | 5 |
2 | 7 | 2007.20 | 38 | 14.88 | 2974 | 1682 | 1.92 / 101.42 | 2 | 9 |
3 | 13 | 1651.32 | 18 | 14.93 | 2538 | 682 | 2.60 / 102.11 | 2 | 11 |
4 | 13 | 1100.52 | 18 | 15.02 | 1823 | 493 | 3.10 / 102.60 | 2 | 11 |
5 | 13 | 461.16 | 18 | 15.19 | 948 | 259 | 3.35 / 102.86 | 2 | 13 |
6 | 13 | 53.68 | 18 | 15.27 | 353 | 97 | 3.45 / 102.96 | 2 | 7 |
7 | 8 | -0.12 | 165 | 15.25 | 273 | 687 | 4.14 / 103.64 | 2 | 20 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.36 | 37 | 15.20 | 411 | 231 | 0.23 / 95.64 | 2 | 3 |
2 | 7 | 2009.52 | 39 | 14.87 | 2960 | 1717 | 1.95 / 97.36 | 2 | 8 |
3 | 13 | 1525.88 | 18 | 14.96 | 2373 | 639 | 2.59 / 98.00 | 2 | 11 |
4 | 13 | 1013.60 | 18 | 15.05 | 1700 | 461 | 3.05 / 98.46 | 2 | 12 |
5 | 13 | 465.08 | 18 | 15.17 | 951 | 260 | 3.31 / 98.72 | 2 | 13 |
6 | 13 | 51.76 | 18 | 15.28 | 353 | 97 | 3.40 / 98.81 | 2 | 9 |
7 | 8 | -0.32 | 165 | 15.26 | 274 | 690 | 4.09 / 99.50 | 2 | 21 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.12 | 37 | 15.21 | 429 | 241 | 0.24 / 91.46 | 2 | 3 |
2 | 7 | 2006.44 | 38 | 14.87 | 2965 | 1675 | 1.92 / 93.13 | 2 | 7 |
3 | 13 | 1706.24 | 18 | 14.92 | 2606 | 700 | 2.62 / 93.83 | 2 | 15 |
4 | 13 | 1194.88 | 18 | 15.00 | 1950 | 526 | 3.14 / 94.36 | 2 | 12 |
5 | 13 | 476.88 | 18 | 15.18 | 971 | 265 | 3.41 / 94.62 | 2 | 12 |
6 | 13 | 62.52 | 18 | 15.27 | 369 | 101 | 3.51 / 94.73 | 2 | 10 |
7 | 8 | -0.16 | 165 | 15.25 | 272 | 684 | 4.19 / 95.41 | 2 | 20 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.60 | 37 | 15.22 | 407 | 229 | 0.23 / 87.35 | 2 | 4 |
2 | 7 | 2008.60 | 39 | 14.87 | 2963 | 1718 | 1.95 / 89.07 | 2 | 12 |
3 | 13 | 1625.96 | 18 | 14.93 | 2493 | 670 | 2.62 / 89.74 | 2 | 11 |
4 | 13 | 1010.28 | 18 | 15.04 | 1693 | 458 | 3.08 / 90.20 | 2 | 11 |
5 | 13 | 404.68 | 18 | 15.20 | 865 | 237 | 3.31 / 90.44 | 2 | 13 |
6 | 13 | 49.88 | 18 | 15.27 | 348 | 96 | 3.41 / 90.53 | 2 | 11 |
7 | 8 | 0.32 | 165 | 15.25 | 272 | 684 | 4.09 / 91.22 | 2 | 24 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.36 | 37 | 15.23 | 407 | 229 | 0.23 / 83.21 | 2 | 3 |
2 | 7 | 2023.48 | 39 | 14.89 | 2993 | 1738 | 1.97 / 84.95 | 2 | 11 |
3 | 13 | 1558.52 | 18 | 14.97 | 2424 | 653 | 2.62 / 85.60 | 2 | 13 |
4 | 13 | 1114.52 | 18 | 15.04 | 1846 | 500 | 3.12 / 86.10 | 2 | 12 |
5 | 13 | 418.48 | 18 | 15.21 | 885 | 242 | 3.36 / 86.34 | 2 | 13 |
6 | 13 | 43.80 | 18 | 15.30 | 341 | 94 | 3.46 / 86.44 | 2 | 9 |
7 | 8 | 0.76 | 165 | 15.27 | 272 | 685 | 4.14 / 87.12 | 2 | 17 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 37 | 15.21 | 407 | 229 | 0.23 / 79.09 | 2 | 4 |
2 | 7 | 2007.32 | 38 | 14.91 | 2979 | 1688 | 1.92 / 80.78 | 2 | 12 |
3 | 13 | 1611.84 | 18 | 14.97 | 2498 | 673 | 2.59 / 81.45 | 2 | 12 |
4 | 13 | 1080.96 | 18 | 15.04 | 1801 | 488 | 3.08 / 81.94 | 2 | 12 |
5 | 13 | 461.80 | 18 | 15.21 | 950 | 260 | 3.34 / 82.20 | 2 | 12 |
6 | 13 | 59.48 | 18 | 15.28 | 364 | 100 | 3.44 / 82.30 | 2 | 11 |
7 | 8 | 0.16 | 165 | 15.27 | 271 | 683 | 4.12 / 82.98 | 2 | 20 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.64 | 37 | 15.22 | 414 | 233 | 0.23 / 75.00 | 2 | 3 |
2 | 7 | 2018.40 | 38 | 14.90 | 2982 | 1688 | 1.92 / 76.69 | 2 | 11 |
3 | 13 | 1561.00 | 18 | 14.97 | 2426 | 654 | 2.58 / 77.35 | 2 | 11 |
4 | 13 | 1066.80 | 18 | 15.05 | 1772 | 480 | 3.06 / 77.83 | 2 | 12 |
5 | 13 | 432.76 | 18 | 15.22 | 905 | 248 | 3.30 / 78.07 | 2 | 13 |
6 | 13 | 49.92 | 18 | 15.30 | 353 | 97 | 3.40 / 78.17 | 2 | 11 |
7 | 8 | 0.28 | 165 | 15.27 | 274 | 690 | 4.09 / 78.86 | 2 | 21 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 37 | 15.22 | 406 | 229 | 0.23 / 70.81 | 2 | 4 |
2 | 7 | 2025.00 | 39 | 14.88 | 3002 | 1742 | 1.97 / 72.55 | 2 | 8 |
3 | 13 | 1591.68 | 18 | 14.96 | 2476 | 667 | 2.64 / 73.22 | 2 | 11 |
4 | 13 | 1074.52 | 18 | 15.04 | 1797 | 486 | 3.12 / 73.70 | 2 | 14 |
5 | 13 | 513.52 | 18 | 15.18 | 1024 | 280 | 3.40 / 73.98 | 2 | 14 |
6 | 13 | 47.72 | 18 | 15.31 | 350 | 96 | 3.50 / 74.08 | 2 | 9 |
7 | 8 | 0.20 | 165 | 15.28 | 274 | 691 | 4.19 / 74.77 | 2 | 21 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.88 | 37 | 15.23 | 410 | 231 | 0.23 / 66.66 | 2 | 3 |
2 | 7 | 2009.64 | 38 | 14.90 | 2974 | 1684 | 1.91 / 68.35 | 2 | 9 |
3 | 13 | 1584.60 | 18 | 14.96 | 2450 | 660 | 2.57 / 69.01 | 2 | 16 |
4 | 13 | 1241.52 | 18 | 15.00 | 2007 | 542 | 3.12 / 69.55 | 2 | 13 |
5 | 13 | 416.76 | 18 | 15.21 | 887 | 243 | 3.36 / 69.79 | 2 | 14 |
6 | 13 | 50.00 | 18 | 15.31 | 350 | 96 | 3.46 / 69.89 | 2 | 11 |
7 | 8 | 0.28 | 165 | 15.27 | 274 | 690 | 4.15 / 70.58 | 2 | 12 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.80 | 37 | 15.23 | 407 | 229 | 0.23 / 62.59 | 2 | 3 |
2 | 7 | 2009.40 | 38 | 14.90 | 2971 | 1682 | 1.91 / 64.27 | 2 | 10 |
3 | 13 | 1627.36 | 18 | 14.96 | 2506 | 675 | 2.59 / 64.95 | 2 | 10 |
4 | 13 | 1031.96 | 18 | 15.06 | 1733 | 470 | 3.06 / 65.42 | 2 | 12 |
5 | 13 | 374.12 | 18 | 15.24 | 828 | 227 | 3.28 / 65.64 | 2 | 14 |
6 | 13 | 51.44 | 18 | 15.30 | 356 | 98 | 3.38 / 65.74 | 2 | 9 |
7 | 8 | 0.52 | 165 | 15.27 | 274 | 690 | 4.07 / 66.43 | 2 | 20 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 37 | 15.23 | 403 | 227 | 0.23 / 58.40 | 2 | 3 |
2 | 7 | 2021.28 | 39 | 14.91 | 2994 | 1741 | 1.97 / 60.14 | 2 | 10 |
3 | 13 | 1657.64 | 18 | 14.97 | 2547 | 686 | 2.65 / 60.83 | 2 | 13 |
4 | 13 | 1049.96 | 18 | 15.07 | 1757 | 477 | 3.13 / 61.30 | 2 | 12 |
5 | 13 | 454.32 | 18 | 15.21 | 941 | 258 | 3.39 / 61.56 | 2 | 14 |
6 | 13 | 49.44 | 18 | 15.31 | 353 | 97 | 3.49 / 61.66 | 2 | 13 |
7 | 8 | -0.04 | 165 | 15.27 | 279 | 703 | 4.19 / 62.36 | 2 | 15 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.64 | 37 | 15.22 | 410 | 231 | 0.23 / 54.35 | 2 | 3 |
2 | 7 | 2006.20 | 39 | 14.91 | 2970 | 1727 | 1.96 / 56.08 | 2 | 9 |
3 | 13 | 1483.28 | 18 | 15.00 | 2330 | 629 | 2.59 / 56.71 | 2 | 11 |
4 | 13 | 1003.40 | 18 | 15.08 | 1700 | 461 | 3.05 / 57.17 | 2 | 13 |
5 | 13 | 326.80 | 18 | 15.27 | 762 | 209 | 3.26 / 57.38 | 2 | 14 |
6 | 13 | 36.28 | 18 | 15.32 | 335 | 92 | 3.35 / 57.47 | 2 | 9 |
7 | 8 | -0.12 | 165 | 15.28 | 277 | 698 | 4.05 / 58.17 | 2 | 18 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.24 | 36 | 15.23 | 432 | 237 | 0.24 / 50.21 | 2 | 3 |
2 | 7 | 2022.32 | 38 | 14.91 | 2993 | 1696 | 1.93 / 51.90 | 2 | 9 |
3 | 13 | 1523.36 | 18 | 14.97 | 2374 | 640 | 2.57 / 52.54 | 2 | 11 |
4 | 13 | 967.44 | 18 | 15.08 | 1648 | 447 | 3.02 / 52.99 | 2 | 12 |
5 | 13 | 476.00 | 18 | 15.19 | 973 | 266 | 3.29 / 53.26 | 2 | 14 |
6 | 13 | 196.68 | 18 | 15.27 | 575 | 158 | 3.44 / 53.42 | 2 | 13 |
7 | 8 | 0.00 | 165 | 15.27 | 281 | 708 | 4.15 / 54.12 | 2 | 19 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.48 | 36 | 15.24 | 414 | 227 | 0.23 / 46.11 | 2 | 3 |
2 | 7 | 2018.32 | 38 | 14.91 | 2991 | 1695 | 1.92 / 47.80 | 2 | 9 |
3 | 13 | 1553.36 | 18 | 14.99 | 2419 | 653 | 2.57 / 48.46 | 2 | 11 |
4 | 13 | 1029.52 | 18 | 15.06 | 1734 | 470 | 3.04 / 48.93 | 2 | 13 |
5 | 13 | 441.36 | 18 | 15.23 | 928 | 254 | 3.30 / 49.18 | 2 | 14 |
6 | 13 | 42.36 | 18 | 15.32 | 342 | 94 | 3.39 / 49.28 | 2 | 11 |
7 | 8 | 0.56 | 165 | 15.29 | 276 | 696 | 4.09 / 49.97 | 2 | 18 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.88 | 36 | 15.25 | 413 | 227 | 0.23 / 42.00 | 2 | 4 |
2 | 7 | 2019.32 | 38 | 14.92 | 2974 | 1686 | 1.91 / 43.69 | 2 | 9 |
3 | 13 | 1633.08 | 18 | 14.97 | 2507 | 676 | 2.59 / 44.36 | 2 | 17 |
4 | 13 | 1035.44 | 18 | 15.07 | 1733 | 470 | 3.06 / 44.83 | 2 | 12 |
5 | 13 | 482.40 | 18 | 15.22 | 980 | 268 | 3.33 / 45.10 | 2 | 13 |
6 | 13 | 32.92 | 18 | 15.32 | 329 | 91 | 3.42 / 45.19 | 2 | 10 |
7 | 8 | -0.32 | 165 | 15.29 | 273 | 689 | 4.11 / 45.88 | 2 | 19 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 36 | 15.27 | 405 | 223 | 0.22 / 37.93 | 2 | 3 |
2 | 7 | 2006.04 | 38 | 14.95 | 2971 | 1688 | 1.91 / 39.62 | 2 | 7 |
3 | 13 | 1584.16 | 18 | 15.01 | 2444 | 660 | 2.57 / 40.28 | 2 | 11 |
4 | 13 | 1048.84 | 18 | 15.09 | 1751 | 476 | 3.05 / 40.75 | 2 | 14 |
5 | 13 | 405.28 | 18 | 15.25 | 869 | 239 | 3.28 / 40.99 | 2 | 12 |
6 | 13 | 29.48 | 18 | 15.33 | 322 | 89 | 3.37 / 41.08 | 2 | 12 |
7 | 8 | 0.04 | 165 | 15.30 | 275 | 694 | 4.07 / 41.78 | 2 | 18 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.76 | 36 | 15.26 | 442 | 243 | 0.24 / 33.78 | 2 | 3 |
2 | 7 | 2023.08 | 38 | 14.95 | 3006 | 1708 | 1.95 / 35.49 | 2 | 8 |
3 | 13 | 1696.72 | 18 | 15.00 | 2617 | 707 | 2.66 / 36.19 | 2 | 12 |
4 | 13 | 1018.12 | 18 | 15.11 | 1721 | 468 | 3.13 / 36.66 | 2 | 13 |
5 | 13 | 430.68 | 18 | 15.27 | 910 | 250 | 3.38 / 36.91 | 2 | 13 |
6 | 13 | 29.24 | 18 | 15.35 | 327 | 90 | 3.47 / 37.00 | 2 | 10 |
7 | 8 | 0.36 | 165 | 15.32 | 280 | 708 | 4.17 / 37.71 | 2 | 20 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.72 | 36 | 15.26 | 438 | 241 | 0.24 / 29.65 | 2 | 4 |
2 | 3 | 1024.16 | 1 | 15.29 | 1782 | 27 | 0.27 / 29.68 | 2 | 7 |
3 | 7 | 2017.92 | 38 | 14.95 | 2991 | 1699 | 1.97 / 31.38 | 2 | 8 |
4 | 13 | 1604.32 | 18 | 15.00 | 2485 | 671 | 2.64 / 32.05 | 2 | 10 |
5 | 13 | 1004.76 | 18 | 15.11 | 1696 | 461 | 3.10 / 32.51 | 2 | 12 |
6 | 13 | 376.44 | 18 | 15.26 | 832 | 229 | 3.33 / 32.74 | 2 | 13 |
7 | 13 | 33.96 | 18 | 15.33 | 333 | 92 | 3.42 / 32.83 | 2 | 10 |
8 | 8 | 0.08 | 165 | 15.31 | 278 | 702 | 4.12 / 33.53 | 2 | 22 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.60 | 34 | 15.25 | 442 | 229 | 0.23 / 24.86 | 2 | 3 |
2 | 10 | 1034.12 | 2 | 15.24 | 1784 | 54 | 0.28 / 24.92 | 2 | 10 |
3 | 7 | 2021.16 | 74 | 14.83 | 2975 | 3265 | 3.55 / 28.18 | 2 | 10 |
4 | 13 | 763.48 | 18 | 15.17 | 1371 | 374 | 3.92 / 28.56 | 2 | 14 |
5 | 13 | 150.60 | 18 | 15.32 | 510 | 141 | 4.06 / 28.70 | 2 | 13 |
6 | 8 | 0.52 | 165 | 15.32 | 283 | 715 | 4.78 / 29.41 | 2 | 15 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.68 | 27 | 15.24 | 447 | 184 | 0.18 / 19.96 | 2 | 3 |
2 | 10 | 1052.68 | 4 | 15.20 | 1810 | 110 | 0.29 / 20.07 | 2 | 7 |
3 | 10 | 1086.32 | 2 | 15.21 | 1867 | 57 | 0.35 / 20.12 | 2 | 9 |
4 | 3 | 1080.80 | 2 | 15.25 | 1882 | 57 | 0.41 / 20.18 | 2 | 9 |
5 | 7 | 2016.40 | 74 | 14.83 | 2981 | 3271 | 3.68 / 23.45 | 2 | 10 |
6 | 13 | 622.68 | 18 | 15.20 | 1178 | 322 | 4.00 / 23.77 | 2 | 13 |
7 | 13 | 167.48 | 18 | 15.31 | 533 | 147 | 4.15 / 23.92 | 2 | 14 |
8 | 8 | -0.08 | 165 | 15.32 | 282 | 713 | 4.86 / 24.63 | 2 | 19 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 29 | 15.28 | 431 | 191 | 0.19 / 15.36 | 2 | 3 |
2 | 3 | 945.68 | -1 | 15.64 | 1 | 0 | 0.00 / 15.36 | 2 | 3 |
3 | 7 | 2014.32 | 74 | 14.82 | 2960 | 3246 | 3.44 / 18.61 | 2 | 10 |
4 | 13 | 599.96 | 18 | 15.20 | 1140 | 312 | 3.75 / 18.92 | 2 | 14 |
5 | 13 | 137.32 | 18 | 15.31 | 482 | 133 | 3.88 / 19.05 | 2 | 11 |
6 | 8 | 0.12 | 165 | 15.29 | 285 | 719 | 4.60 / 19.77 | 2 | 16 |
Average= | 3.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 27 | 15.28 | 434 | 179 | 0.18 / 11.69 | 2 | 3 |
2 | 7 | 1510.60 | 74 | 14.99 | 2335 | 2590 | 2.77 / 14.28 | 2 | 13 |
3 | 13 | 239.36 | 18 | 15.32 | 637 | 176 | 2.94 / 14.45 | 2 | 12 |
4 | 8 | -0.08 | 165 | 15.33 | 284 | 718 | 3.66 / 15.17 | 2 | 19 |
Average= | 3.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 25 | 15.29 | 428 | 164 | 0.16 / 8.03 | 2 | 4 |
2 | 10 | 1030.08 | 2 | 15.27 | 1760 | 54 | 0.22 / 8.08 | 2 | 8 |
3 | 7 | 1507.00 | 74 | 15.00 | 2324 | 2580 | 2.80 / 10.66 | 2 | 11 |
4 | 13 | 140.52 | 18 | 15.34 | 490 | 135 | 2.93 / 10.80 | 2 | 12 |
5 | 8 | -0.08 | 165 | 15.33 | 281 | 711 | 3.64 / 11.51 | 2 | 14 |
Average= | 2.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.44 | 31 | 15.31 | 433 | 206 | 0.21 / 4.44 | 2 | 4 |
2 | 3 | 794.12 | -4 | 15.66 | 0 | 0 | 0.00 / 4.44 | 2 | 4 |
3 | 3 | 939.00 | -1 | 15.68 | 0 | 0 | 0.00 / 4.44 | 2 | 4 |
4 | 7 | 1508.44 | 74 | 15.00 | 2325 | 2581 | 2.79 / 7.02 | 2 | 8 |
5 | 13 | 149.40 | 18 | 15.34 | 497 | 137 | 2.92 / 7.16 | 2 | 12 |
6 | 8 | 0.24 | 165 | 15.34 | 278 | 704 | 3.63 / 7.87 | 2 | 20 |
Average= | 2.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.16 | 26 | 15.50 | 395 | 159 | 0.16 / 1.67 | 2 | 3 |
2 | 7 | 991.52 | 74 | 15.17 | 1636 | 1837 | 2.00 / 3.51 | 2 | 11 |
3 | 8 | -0.04 | 165 | 15.37 | 287 | 728 | 2.72 / 4.24 | 2 | 17 |
Average= | 2.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 97.72 | 26 | 15.62 | 385 | 156 | 0.16 / 0.16 | 2 | 3 |
2 | 7 | 112.92 | 74 | 15.60 | 403 | 465 | 0.62 / 0.62 | 2 | 3 |
3 | 8 | 0.40 | 240 | 15.57 | 239 | 893 | 1.51 / 1.51 | 2 | 18 |
Average= | 1.51 (KJ/cycle) |