SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 75.96 | 22 | 15.60 | 334 | 115 | 0.11 / 0.11 | 3 | 3 |
2 | 7 | 88.12 | 74 | 15.60 | 340 | 392 | 0.51 / 0.51 | 3 | 3 |
3 | 8 | 0.32 | 240 | 15.56 | 210 | 784 | 1.29 / 1.29 | 3 | 13 |
Average= | 1.29 (KJ/cycle) |