1 | 2 | 117.36 | 28 | 14.92 | 467 | 195 | 0.20 / 746.23 | 3 | 3 |
2 | 7 | 2003.80 | 53 | 14.86 | 3106 | 2446 | 2.64 / 748.68 | 2 | 3 |
3 | 13 | 893.84 | 16 | 14.83 | 1613 | 383 | 3.02 / 749.06 | 2 | 4 |
4 | 13 | 355.88 | 16 | 14.94 | 849 | 203 | 3.23 / 749.26 | 2 | 3 |
5 | 13 | 53.88 | 16 | 15.00 | 392 | 94 | 3.32 / 749.36 | 2 | 3 |
6 | 8 | 0.08 | 165 | 14.98 | 296 | 732 | 4.05 / 750.09 | 2 | 5 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.84 | 28 | 14.93 | 466 | 195 | 0.19 / 742.18 | 3 | 3 |
2 | 7 | 2008.44 | 52 | 14.85 | 3121 | 2410 | 2.60 / 744.59 | 2 | 3 |
3 | 13 | 990.60 | 16 | 14.81 | 1748 | 414 | 3.02 / 745.01 | 2 | 4 |
4 | 13 | 431.36 | 16 | 14.91 | 957 | 228 | 3.25 / 745.23 | 2 | 3 |
5 | 13 | 67.84 | 16 | 14.99 | 406 | 97 | 3.34 / 745.33 | 2 | 3 |
6 | 8 | 0.16 | 165 | 14.96 | 285 | 703 | 4.05 / 746.04 | 2 | 6 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 28 | 14.95 | 447 | 187 | 0.19 / 738.08 | 2 | 3 |
2 | 7 | 2008.04 | 53 | 14.86 | 3114 | 2453 | 2.64 / 740.54 | 2 | 3 |
3 | 13 | 1013.24 | 16 | 14.82 | 1781 | 422 | 3.06 / 740.96 | 2 | 3 |
4 | 13 | 440.20 | 16 | 14.92 | 981 | 234 | 3.30 / 741.19 | 2 | 3 |
5 | 13 | 76.28 | 16 | 14.99 | 423 | 101 | 3.40 / 741.29 | 2 | 3 |
6 | 8 | -0.04 | 165 | 14.97 | 281 | 694 | 4.09 / 741.99 | 2 | 5 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.88 | 28 | 14.93 | 467 | 195 | 0.20 / 733.94 | 3 | 3 |
2 | 7 | 2009.40 | 52 | 14.85 | 3116 | 2406 | 2.60 / 736.35 | 2 | 3 |
3 | 13 | 1003.36 | 16 | 14.81 | 1783 | 422 | 3.02 / 736.77 | 2 | 4 |
4 | 13 | 420.40 | 16 | 14.92 | 942 | 225 | 3.25 / 736.99 | 2 | 4 |
5 | 13 | 65.04 | 16 | 14.99 | 396 | 95 | 3.34 / 737.09 | 2 | 3 |
6 | 8 | 0.12 | 165 | 14.97 | 277 | 684 | 4.03 / 737.77 | 2 | 5 |
7 | 14 | 0.12 | 30 | 14.95 | 275 | 123 | 4.15 / 737.90 | 3 | 4 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.64 | 28 | 14.93 | 485 | 203 | 0.20 / 730.02 | 3 | 3 |
2 | 7 | 2004.28 | 52 | 14.84 | 3108 | 2398 | 2.60 / 732.42 | 2 | 3 |
3 | 13 | 997.20 | 16 | 14.82 | 1753 | 416 | 3.02 / 732.83 | 2 | 3 |
4 | 13 | 424.64 | 16 | 14.91 | 956 | 228 | 3.24 / 733.06 | 2 | 4 |
5 | 8 | 0.16 | 165 | 14.97 | 276 | 682 | 3.93 / 733.74 | 2 | 5 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.28 | 28 | 14.93 | 467 | 195 | 0.20 / 725.91 | 2 | 3 |
2 | 7 | 2011.32 | 53 | 14.85 | 3124 | 2459 | 2.65 / 728.36 | 2 | 3 |
3 | 13 | 1009.80 | 16 | 14.81 | 1778 | 421 | 3.08 / 728.79 | 2 | 5 |
4 | 13 | 430.44 | 16 | 14.92 | 965 | 230 | 3.31 / 729.02 | 2 | 4 |
5 | 13 | 68.24 | 16 | 15.00 | 406 | 97 | 3.40 / 729.11 | 2 | 3 |
6 | 8 | -0.04 | 165 | 14.97 | 285 | 704 | 4.11 / 729.82 | 2 | 4 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.84 | 28 | 14.92 | 468 | 196 | 0.20 / 721.83 | 2 | 3 |
2 | 7 | 2008.56 | 53 | 14.86 | 3129 | 2464 | 2.66 / 724.29 | 2 | 3 |
3 | 13 | 1007.44 | 16 | 14.82 | 1771 | 420 | 3.08 / 724.71 | 2 | 4 |
4 | 13 | 434.48 | 16 | 14.92 | 961 | 229 | 3.31 / 724.94 | 2 | 4 |
5 | 13 | 35.28 | 16 | 15.00 | 345 | 83 | 3.39 / 725.02 | 2 | 3 |
6 | 8 | 0.08 | 165 | 14.98 | 278 | 687 | 4.08 / 725.71 | 2 | 5 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.36 | 28 | 14.94 | 464 | 194 | 0.19 / 717.74 | 3 | 3 |
2 | 7 | 2004.48 | 53 | 14.85 | 3112 | 2449 | 2.64 / 720.19 | 2 | 3 |
3 | 13 | 999.76 | 16 | 14.80 | 1771 | 419 | 3.06 / 720.61 | 2 | 3 |
4 | 13 | 426.68 | 16 | 14.91 | 955 | 228 | 3.29 / 720.84 | 2 | 4 |
5 | 13 | 66.20 | 16 | 14.99 | 395 | 95 | 3.39 / 720.93 | 2 | 3 |
6 | 8 | 0.04 | 165 | 14.97 | 284 | 701 | 4.09 / 721.63 | 2 | 6 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.12 | 28 | 14.92 | 485 | 203 | 0.20 / 713.78 | 2 | 3 |
2 | 7 | 2007.28 | 53 | 14.85 | 3124 | 2459 | 2.66 / 716.24 | 2 | 3 |
3 | 13 | 882.68 | 16 | 14.83 | 1600 | 380 | 3.04 / 716.62 | 2 | 4 |
4 | 13 | 457.36 | 16 | 14.90 | 1004 | 239 | 3.28 / 716.86 | 2 | 3 |
5 | 8 | 0.12 | 165 | 14.97 | 279 | 689 | 3.97 / 717.54 | 2 | 5 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.04 | 28 | 14.92 | 479 | 200 | 0.20 / 709.71 | 2 | 3 |
2 | 7 | 2007.52 | 53 | 14.84 | 3097 | 2436 | 2.64 / 712.15 | 2 | 3 |
3 | 13 | 886.16 | 16 | 14.83 | 1608 | 382 | 3.02 / 712.53 | 2 | 3 |
4 | 13 | 470.32 | 16 | 14.91 | 1017 | 243 | 3.26 / 712.77 | 2 | 5 |
5 | 13 | 81.20 | 16 | 14.99 | 415 | 100 | 3.36 / 712.87 | 2 | 4 |
6 | 8 | -0.08 | 165 | 14.96 | 286 | 706 | 4.07 / 713.58 | 2 | 5 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.28 | 28 | 14.92 | 500 | 209 | 0.21 / 705.60 | 2 | 3 |
2 | 7 | 2009.96 | 53 | 14.85 | 3120 | 2456 | 2.66 / 708.06 | 2 | 3 |
3 | 13 | 1002.40 | 16 | 14.81 | 1763 | 418 | 3.08 / 708.48 | 2 | 4 |
4 | 13 | 433.72 | 16 | 14.91 | 971 | 232 | 3.31 / 708.71 | 2 | 4 |
5 | 13 | 67.96 | 16 | 14.99 | 400 | 96 | 3.41 / 708.80 | 2 | 3 |
6 | 8 | 0.12 | 165 | 14.96 | 286 | 706 | 4.12 / 709.51 | 2 | 6 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.08 | 28 | 14.92 | 468 | 196 | 0.20 / 701.47 | 2 | 3 |
2 | 7 | 2004.36 | 53 | 14.83 | 3108 | 2443 | 2.64 / 703.91 | 2 | 3 |
3 | 13 | 895.24 | 16 | 14.82 | 1620 | 384 | 3.02 / 704.30 | 2 | 4 |
4 | 13 | 479.08 | 16 | 14.90 | 1031 | 246 | 3.27 / 704.54 | 2 | 3 |
5 | 13 | 87.64 | 16 | 14.98 | 439 | 105 | 3.37 / 704.65 | 2 | 3 |
6 | 8 | 0.16 | 165 | 14.96 | 302 | 745 | 4.12 / 705.39 | 2 | 4 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 28 | 14.93 | 448 | 187 | 0.19 / 697.34 | 3 | 3 |
2 | 7 | 2006.24 | 53 | 14.84 | 3105 | 2442 | 2.63 / 699.78 | 2 | 3 |
3 | 13 | 1012.36 | 16 | 14.80 | 1786 | 423 | 3.05 / 700.21 | 2 | 3 |
4 | 13 | 437.44 | 16 | 14.91 | 987 | 235 | 3.29 / 700.44 | 2 | 4 |
5 | 13 | 69.56 | 16 | 14.99 | 412 | 99 | 3.39 / 700.54 | 2 | 3 |
6 | 8 | -0.12 | 165 | 14.96 | 297 | 733 | 4.12 / 701.27 | 2 | 3 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.08 | 28 | 14.95 | 464 | 194 | 0.19 / 693.30 | 3 | 3 |
2 | 7 | 2007.16 | 52 | 14.85 | 3115 | 2405 | 2.60 / 695.70 | 2 | 3 |
3 | 13 | 880.56 | 16 | 14.84 | 1601 | 380 | 2.98 / 696.08 | 2 | 4 |
4 | 13 | 456.28 | 16 | 14.91 | 994 | 237 | 3.22 / 696.32 | 2 | 4 |
5 | 8 | 0.20 | 165 | 14.98 | 285 | 704 | 3.92 / 697.03 | 2 | 4 |
6 | 14 | 0.20 | 30 | 14.95 | 289 | 130 | 4.05 / 697.16 | 2 | 6 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 28 | 14.93 | 448 | 187 | 0.19 / 689.19 | 2 | 3 |
2 | 7 | 2003.88 | 53 | 14.85 | 3116 | 2452 | 2.64 / 691.64 | 2 | 3 |
3 | 13 | 1009.12 | 16 | 14.81 | 1771 | 420 | 3.06 / 692.06 | 2 | 4 |
4 | 13 | 433.40 | 16 | 14.92 | 959 | 229 | 3.29 / 692.29 | 2 | 4 |
5 | 13 | 72.60 | 16 | 14.99 | 412 | 99 | 3.39 / 692.39 | 2 | 3 |
6 | 8 | 0.08 | 165 | 14.98 | 288 | 712 | 4.10 / 693.10 | 2 | 4 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.28 | 28 | 14.93 | 481 | 201 | 0.20 / 685.15 | 2 | 3 |
2 | 7 | 2007.40 | 52 | 14.85 | 3128 | 2415 | 2.62 / 687.57 | 2 | 2 |
3 | 13 | 879.28 | 16 | 14.85 | 1593 | 378 | 3.00 / 687.95 | 2 | 5 |
4 | 13 | 457.12 | 16 | 14.92 | 1017 | 243 | 3.24 / 688.19 | 2 | 3 |
5 | 13 | 80.20 | 16 | 15.00 | 431 | 103 | 3.34 / 688.29 | 2 | 3 |
6 | 8 | 0.08 | 165 | 14.98 | 288 | 712 | 4.05 / 689.01 | 2 | 5 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.56 | 28 | 14.93 | 487 | 204 | 0.20 / 681.01 | 3 | 3 |
2 | 7 | 2005.88 | 53 | 14.86 | 3115 | 2453 | 2.66 / 683.47 | 2 | 3 |
3 | 13 | 995.08 | 16 | 14.82 | 1762 | 418 | 3.07 / 683.88 | 2 | 4 |
4 | 13 | 420.40 | 16 | 14.94 | 944 | 226 | 3.30 / 684.11 | 2 | 3 |
5 | 13 | 65.20 | 16 | 15.01 | 409 | 98 | 3.40 / 684.21 | 2 | 3 |
6 | 8 | 0.08 | 165 | 14.98 | 301 | 744 | 4.14 / 684.95 | 2 | 6 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.56 | 28 | 14.92 | 463 | 193 | 0.19 / 676.89 | 2 | 3 |
2 | 7 | 2010.00 | 52 | 14.86 | 3129 | 2418 | 2.61 / 679.31 | 2 | 3 |
3 | 13 | 1000.04 | 16 | 14.83 | 1772 | 420 | 3.03 / 679.73 | 2 | 4 |
4 | 13 | 424.96 | 16 | 14.94 | 963 | 230 | 3.26 / 679.96 | 2 | 3 |
5 | 13 | 73.68 | 16 | 15.00 | 433 | 104 | 3.37 / 680.06 | 2 | 3 |
6 | 8 | -0.04 | 165 | 14.98 | 302 | 746 | 4.11 / 680.81 | 2 | 6 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.12 | 28 | 14.93 | 472 | 197 | 0.20 / 672.82 | 2 | 3 |
2 | 7 | 2007.00 | 53 | 14.85 | 3111 | 2449 | 2.65 / 675.27 | 2 | 3 |
3 | 13 | 882.32 | 16 | 14.84 | 1595 | 379 | 3.02 / 675.65 | 2 | 4 |
4 | 13 | 462.32 | 16 | 14.91 | 1009 | 241 | 3.27 / 675.89 | 2 | 4 |
5 | 13 | 85.20 | 16 | 15.00 | 439 | 105 | 3.37 / 675.99 | 2 | 3 |
6 | 8 | 0.08 | 165 | 14.97 | 285 | 704 | 4.07 / 676.70 | 2 | 6 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.68 | 28 | 14.93 | 483 | 202 | 0.20 / 668.73 | 3 | 3 |
2 | 7 | 2010.32 | 53 | 14.86 | 3115 | 2453 | 2.66 / 671.18 | 2 | 3 |
3 | 13 | 990.84 | 16 | 14.82 | 1750 | 415 | 3.07 / 671.60 | 2 | 3 |
4 | 13 | 416.64 | 16 | 14.93 | 948 | 226 | 3.30 / 671.82 | 2 | 3 |
5 | 13 | 72.52 | 16 | 15.01 | 409 | 98 | 3.39 / 671.92 | 2 | 3 |
6 | 8 | -0.20 | 165 | 14.98 | 283 | 699 | 4.09 / 672.62 | 2 | 4 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 28 | 14.93 | 466 | 195 | 0.19 / 664.60 | 2 | 3 |
2 | 7 | 2007.28 | 53 | 14.85 | 3123 | 2458 | 2.65 / 667.06 | 2 | 3 |
3 | 13 | 887.80 | 16 | 14.84 | 1610 | 382 | 3.04 / 667.44 | 2 | 4 |
4 | 13 | 462.24 | 16 | 14.92 | 1010 | 241 | 3.28 / 667.68 | 2 | 4 |
5 | 13 | 80.32 | 16 | 15.01 | 429 | 103 | 3.38 / 667.79 | 2 | 3 |
6 | 8 | 0.12 | 165 | 14.98 | 300 | 742 | 4.12 / 668.53 | 2 | 4 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 28 | 14.94 | 449 | 188 | 0.19 / 660.50 | 3 | 3 |
2 | 7 | 2003.80 | 52 | 14.86 | 3111 | 2404 | 2.59 / 662.91 | 2 | 3 |
3 | 13 | 1000.20 | 16 | 14.82 | 1770 | 420 | 3.01 / 663.33 | 2 | 3 |
4 | 13 | 425.00 | 16 | 14.93 | 957 | 229 | 3.24 / 663.56 | 2 | 4 |
5 | 13 | 71.08 | 16 | 15.01 | 428 | 103 | 3.34 / 663.66 | 2 | 3 |
6 | 8 | 0.12 | 165 | 14.98 | 303 | 749 | 4.09 / 664.41 | 2 | 4 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 28 | 14.93 | 448 | 187 | 0.19 / 656.43 | 2 | 3 |
2 | 7 | 2003.64 | 53 | 14.86 | 3110 | 2449 | 2.64 / 658.88 | 2 | 3 |
3 | 13 | 876.04 | 16 | 14.85 | 1589 | 378 | 3.01 / 659.26 | 2 | 4 |
4 | 13 | 452.24 | 16 | 14.93 | 998 | 238 | 3.25 / 659.50 | 2 | 3 |
5 | 13 | 80.68 | 16 | 15.01 | 433 | 104 | 3.36 / 659.60 | 2 | 3 |
6 | 8 | 0.12 | 165 | 14.98 | 289 | 714 | 4.07 / 660.32 | 2 | 4 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 28 | 14.93 | 436 | 182 | 0.18 / 652.26 | 3 | 3 |
2 | 7 | 2007.16 | 53 | 14.86 | 3128 | 2464 | 2.65 / 654.72 | 2 | 3 |
3 | 13 | 990.08 | 16 | 14.83 | 1750 | 415 | 3.06 / 655.14 | 2 | 4 |
4 | 13 | 546.36 | 16 | 14.90 | 1130 | 269 | 3.33 / 655.41 | 2 | 4 |
5 | 13 | 116.04 | 16 | 14.99 | 488 | 117 | 3.45 / 655.52 | 2 | 3 |
6 | 8 | 0.08 | 165 | 14.98 | 292 | 722 | 4.17 / 656.24 | 2 | 5 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 28 | 14.94 | 449 | 188 | 0.19 / 648.24 | 3 | 3 |
2 | 7 | 2005.96 | 52 | 14.85 | 3119 | 2408 | 2.60 / 650.65 | 2 | 3 |
3 | 13 | 994.68 | 16 | 14.83 | 1757 | 417 | 3.01 / 651.06 | 2 | 3 |
4 | 13 | 425.84 | 16 | 14.94 | 952 | 228 | 3.24 / 651.29 | 2 | 5 |
5 | 13 | 73.88 | 16 | 15.00 | 408 | 98 | 3.34 / 651.39 | 2 | 3 |
6 | 8 | 0.20 | 165 | 14.98 | 278 | 687 | 4.03 / 652.08 | 2 | 8 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.48 | 28 | 14.94 | 465 | 195 | 0.19 / 644.13 | 3 | 3 |
2 | 7 | 2003.20 | 53 | 14.87 | 3122 | 2460 | 2.65 / 646.59 | 2 | 3 |
3 | 13 | 981.60 | 16 | 14.84 | 1745 | 414 | 3.07 / 647.00 | 2 | 5 |
4 | 13 | 417.24 | 16 | 14.94 | 946 | 226 | 3.30 / 647.23 | 2 | 3 |
5 | 13 | 69.32 | 16 | 15.01 | 410 | 98 | 3.39 / 647.33 | 2 | 3 |
6 | 8 | 0.00 | 165 | 14.99 | 293 | 725 | 4.12 / 648.05 | 2 | 6 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.64 | 28 | 14.95 | 469 | 196 | 0.20 / 640.03 | 2 | 3 |
2 | 7 | 2002.64 | 53 | 14.86 | 3105 | 2445 | 2.64 / 642.48 | 2 | 3 |
3 | 13 | 979.32 | 16 | 14.83 | 1743 | 414 | 3.06 / 642.89 | 2 | 4 |
4 | 13 | 416.60 | 16 | 14.94 | 946 | 226 | 3.28 / 643.12 | 2 | 3 |
5 | 13 | 70.36 | 16 | 15.01 | 410 | 98 | 3.38 / 643.21 | 2 | 3 |
6 | 8 | 0.04 | 165 | 14.99 | 290 | 717 | 4.10 / 643.93 | 2 | 4 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.64 | 28 | 14.94 | 483 | 202 | 0.20 / 635.99 | 3 | 3 |
2 | 7 | 2005.56 | 52 | 14.86 | 3104 | 2399 | 2.60 / 638.39 | 2 | 3 |
3 | 13 | 989.40 | 16 | 14.82 | 1748 | 414 | 3.02 / 638.80 | 2 | 3 |
4 | 13 | 423.52 | 16 | 14.94 | 956 | 229 | 3.24 / 639.03 | 2 | 4 |
5 | 13 | 71.20 | 16 | 15.02 | 406 | 98 | 3.34 / 639.13 | 2 | 3 |
6 | 8 | 0.12 | 165 | 14.99 | 286 | 707 | 4.05 / 639.83 | 2 | 4 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.72 | 28 | 14.94 | 474 | 198 | 0.20 / 631.86 | 2 | 3 |
2 | 7 | 2009.32 | 53 | 14.86 | 3116 | 2454 | 2.65 / 634.31 | 2 | 3 |
3 | 13 | 990.80 | 16 | 14.83 | 1759 | 417 | 3.07 / 634.73 | 2 | 3 |
4 | 13 | 421.80 | 16 | 14.94 | 961 | 230 | 3.30 / 634.96 | 2 | 3 |
5 | 13 | 71.12 | 16 | 15.01 | 422 | 101 | 3.40 / 635.06 | 2 | 3 |
6 | 8 | 0.16 | 165 | 14.99 | 292 | 722 | 4.12 / 635.79 | 2 | 4 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.24 | 28 | 14.93 | 476 | 199 | 0.20 / 627.78 | 2 | 3 |
2 | 7 | 2004.44 | 53 | 14.86 | 3112 | 2451 | 2.65 / 630.23 | 2 | 3 |
3 | 13 | 988.52 | 16 | 14.83 | 1737 | 412 | 3.06 / 630.64 | 2 | 4 |
4 | 13 | 415.76 | 16 | 14.94 | 938 | 224 | 3.29 / 630.87 | 2 | 3 |
5 | 13 | 65.80 | 16 | 15.01 | 398 | 96 | 3.38 / 630.96 | 2 | 3 |
6 | 8 | 0.08 | 165 | 14.99 | 283 | 700 | 4.08 / 631.66 | 2 | 5 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 28 | 14.96 | 439 | 184 | 0.18 / 623.69 | 3 | 3 |
2 | 7 | 2006.80 | 53 | 14.86 | 3115 | 2453 | 2.64 / 626.15 | 2 | 3 |
3 | 13 | 985.96 | 16 | 14.84 | 1746 | 415 | 3.05 / 626.56 | 2 | 4 |
4 | 13 | 411.20 | 16 | 14.95 | 932 | 223 | 3.27 / 626.78 | 2 | 4 |
5 | 13 | 65.72 | 16 | 15.01 | 404 | 97 | 3.37 / 626.88 | 2 | 3 |
6 | 8 | 0.08 | 165 | 14.99 | 283 | 700 | 4.07 / 627.58 | 2 | 5 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.80 | 28 | 14.94 | 466 | 195 | 0.19 / 619.62 | 2 | 4 |
2 | 7 | 2007.88 | 53 | 14.88 | 3127 | 2466 | 2.66 / 622.08 | 2 | 3 |
3 | 13 | 873.92 | 16 | 14.87 | 1590 | 378 | 3.04 / 622.46 | 2 | 4 |
4 | 13 | 457.00 | 16 | 14.94 | 1002 | 240 | 3.28 / 622.70 | 2 | 3 |
5 | 13 | 76.72 | 16 | 15.02 | 419 | 101 | 3.38 / 622.80 | 2 | 3 |
6 | 8 | -0.08 | 165 | 15.00 | 285 | 705 | 4.08 / 623.51 | 2 | 8 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.00 | 28 | 14.94 | 476 | 199 | 0.20 / 615.59 | 3 | 3 |
2 | 7 | 2004.20 | 52 | 14.87 | 3111 | 2406 | 2.60 / 618.00 | 2 | 3 |
3 | 13 | 883.44 | 16 | 14.85 | 1598 | 380 | 2.98 / 618.38 | 2 | 4 |
4 | 13 | 456.52 | 16 | 14.93 | 1000 | 239 | 3.22 / 618.61 | 2 | 4 |
5 | 13 | 79.68 | 16 | 15.01 | 424 | 102 | 3.33 / 618.72 | 2 | 3 |
6 | 8 | 0.08 | 165 | 14.99 | 286 | 707 | 4.03 / 619.42 | 2 | 4 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 28 | 14.95 | 443 | 185 | 0.19 / 611.46 | 3 | 3 |
2 | 7 | 2006.52 | 53 | 14.86 | 3117 | 2455 | 2.64 / 613.91 | 2 | 3 |
3 | 13 | 994.12 | 16 | 14.83 | 1752 | 416 | 3.06 / 614.33 | 2 | 4 |
4 | 13 | 423.48 | 16 | 14.93 | 950 | 227 | 3.28 / 614.56 | 2 | 5 |
5 | 13 | 130.72 | 16 | 15.00 | 509 | 122 | 3.41 / 614.68 | 2 | 3 |
6 | 8 | 0.00 | 165 | 14.99 | 288 | 712 | 4.12 / 615.39 | 2 | 5 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.00 | 28 | 14.94 | 485 | 203 | 0.20 / 607.37 | 3 | 3 |
2 | 7 | 2006.80 | 52 | 14.88 | 3121 | 2415 | 2.62 / 609.78 | 2 | 3 |
3 | 13 | 986.20 | 16 | 14.85 | 1738 | 413 | 3.03 / 610.20 | 2 | 4 |
4 | 13 | 544.56 | 16 | 14.91 | 1116 | 266 | 3.30 / 610.46 | 2 | 4 |
5 | 13 | 110.24 | 16 | 15.02 | 468 | 112 | 3.41 / 610.58 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.00 | 282 | 698 | 4.11 / 611.27 | 2 | 5 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.28 | 28 | 14.94 | 476 | 199 | 0.20 / 603.22 | 2 | 3 |
2 | 7 | 2008.28 | 53 | 14.87 | 3109 | 2450 | 2.65 / 605.67 | 2 | 3 |
3 | 13 | 1001.52 | 16 | 14.83 | 1780 | 422 | 3.07 / 606.09 | 2 | 5 |
4 | 13 | 427.28 | 16 | 14.94 | 969 | 232 | 3.30 / 606.33 | 2 | 3 |
5 | 13 | 73.76 | 16 | 15.01 | 427 | 103 | 3.41 / 606.43 | 2 | 3 |
6 | 8 | 0.04 | 165 | 14.98 | 299 | 739 | 4.14 / 607.17 | 2 | 5 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.56 | 28 | 14.95 | 475 | 199 | 0.20 / 599.10 | 2 | 3 |
2 | 7 | 2007.68 | 53 | 14.87 | 3120 | 2459 | 2.66 / 601.56 | 2 | 3 |
3 | 13 | 884.44 | 16 | 14.86 | 1613 | 384 | 3.04 / 601.95 | 2 | 3 |
4 | 13 | 457.04 | 16 | 14.94 | 1012 | 242 | 3.28 / 602.19 | 2 | 5 |
5 | 13 | 80.52 | 16 | 15.03 | 433 | 104 | 3.39 / 602.29 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.00 | 295 | 730 | 4.12 / 603.02 | 2 | 4 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.04 | 28 | 14.95 | 496 | 208 | 0.21 / 594.99 | 2 | 3 |
2 | 7 | 2003.24 | 53 | 14.87 | 3109 | 2450 | 2.66 / 597.44 | 2 | 3 |
3 | 13 | 991.52 | 16 | 14.83 | 1762 | 418 | 3.08 / 597.86 | 2 | 3 |
4 | 13 | 423.04 | 16 | 14.95 | 960 | 230 | 3.31 / 598.09 | 2 | 4 |
5 | 13 | 69.52 | 16 | 15.02 | 418 | 100 | 3.41 / 598.19 | 2 | 3 |
6 | 8 | -0.08 | 165 | 14.99 | 290 | 717 | 4.12 / 598.90 | 2 | 5 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.04 | 28 | 14.94 | 473 | 198 | 0.20 / 590.85 | 2 | 3 |
2 | 7 | 2007.12 | 52 | 14.86 | 3118 | 2409 | 2.61 / 593.26 | 2 | 3 |
3 | 13 | 994.96 | 16 | 14.83 | 1756 | 417 | 3.02 / 593.68 | 2 | 4 |
4 | 13 | 429.32 | 16 | 14.94 | 955 | 228 | 3.25 / 593.91 | 2 | 3 |
5 | 13 | 74.24 | 16 | 15.02 | 434 | 104 | 3.36 / 594.01 | 2 | 3 |
6 | 8 | 0.00 | 165 | 14.99 | 312 | 772 | 4.13 / 594.78 | 2 | 5 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.40 | 28 | 14.95 | 497 | 208 | 0.21 / 586.72 | 3 | 3 |
2 | 7 | 2007.64 | 53 | 14.87 | 3116 | 2456 | 2.66 / 589.17 | 2 | 3 |
3 | 13 | 992.24 | 16 | 14.84 | 1773 | 421 | 3.08 / 589.59 | 2 | 4 |
4 | 13 | 422.76 | 16 | 14.95 | 962 | 230 | 3.31 / 589.82 | 2 | 3 |
5 | 13 | 71.00 | 16 | 15.02 | 424 | 102 | 3.42 / 589.92 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.01 | 294 | 728 | 4.14 / 590.65 | 2 | 5 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.64 | 28 | 14.96 | 495 | 207 | 0.21 / 582.56 | 3 | 3 |
2 | 7 | 2008.76 | 53 | 14.88 | 3121 | 2461 | 2.67 / 585.02 | 2 | 3 |
3 | 13 | 891.24 | 16 | 14.86 | 1624 | 386 | 3.05 / 585.41 | 2 | 3 |
4 | 13 | 476.12 | 16 | 14.93 | 1035 | 247 | 3.30 / 585.65 | 2 | 4 |
5 | 13 | 88.64 | 16 | 15.03 | 450 | 108 | 3.41 / 585.76 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.01 | 301 | 745 | 4.16 / 586.51 | 2 | 7 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.24 | 28 | 14.96 | 491 | 206 | 0.21 / 578.38 | 2 | 3 |
2 | 7 | 2009.16 | 53 | 14.88 | 3125 | 2464 | 2.67 / 580.84 | 2 | 3 |
3 | 13 | 1000.12 | 16 | 14.83 | 1776 | 421 | 3.09 / 581.26 | 2 | 3 |
4 | 13 | 423.00 | 16 | 14.96 | 962 | 230 | 3.32 / 581.50 | 2 | 4 |
5 | 13 | 72.52 | 16 | 15.02 | 425 | 102 | 3.42 / 581.60 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.00 | 305 | 755 | 4.18 / 582.35 | 2 | 5 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.52 | 28 | 14.97 | 494 | 207 | 0.21 / 574.23 | 2 | 3 |
2 | 7 | 2007.72 | 53 | 14.87 | 3122 | 2460 | 2.67 / 576.69 | 2 | 3 |
3 | 13 | 999.52 | 16 | 14.84 | 1783 | 423 | 3.09 / 577.11 | 2 | 4 |
4 | 13 | 417.96 | 16 | 14.96 | 957 | 229 | 3.32 / 577.34 | 2 | 3 |
5 | 13 | 65.32 | 16 | 15.03 | 406 | 98 | 3.42 / 577.44 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.00 | 297 | 735 | 4.15 / 578.17 | 2 | 5 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.44 | 28 | 14.95 | 482 | 202 | 0.20 / 570.06 | 3 | 3 |
2 | 7 | 2005.16 | 53 | 14.87 | 3118 | 2457 | 2.66 / 572.52 | 2 | 3 |
3 | 13 | 1000.44 | 16 | 14.84 | 1777 | 422 | 3.08 / 572.94 | 2 | 4 |
4 | 13 | 423.48 | 16 | 14.95 | 964 | 231 | 3.31 / 573.17 | 2 | 4 |
5 | 13 | 65.52 | 16 | 15.03 | 410 | 99 | 3.41 / 573.27 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.00 | 302 | 747 | 4.16 / 574.02 | 2 | 6 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.48 | 28 | 14.97 | 486 | 204 | 0.20 / 565.73 | 2 | 3 |
2 | 7 | 2005.44 | 53 | 14.88 | 3103 | 2447 | 2.65 / 568.18 | 2 | 3 |
3 | 13 | 985.00 | 16 | 14.85 | 1746 | 415 | 3.07 / 568.59 | 2 | 4 |
4 | 13 | 539.60 | 16 | 14.92 | 1134 | 271 | 3.34 / 568.86 | 2 | 3 |
5 | 13 | 111.40 | 16 | 15.02 | 488 | 117 | 3.45 / 568.98 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.00 | 302 | 747 | 4.20 / 569.73 | 2 | 5 |
7 | 14 | 0.20 | 30 | 14.98 | 301 | 135 | 4.34 / 569.86 | 2 | 8 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.20 | 28 | 14.95 | 500 | 209 | 0.21 / 561.62 | 3 | 3 |
2 | 7 | 2003.76 | 52 | 14.89 | 3125 | 2420 | 2.63 / 564.04 | 2 | 3 |
3 | 13 | 876.92 | 16 | 14.87 | 1608 | 383 | 3.01 / 564.43 | 2 | 4 |
4 | 13 | 455.00 | 16 | 14.95 | 1013 | 242 | 3.25 / 564.67 | 2 | 4 |
5 | 13 | 76.32 | 16 | 15.03 | 438 | 105 | 3.36 / 564.77 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.01 | 304 | 753 | 4.11 / 565.53 | 2 | 6 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.12 | 28 | 14.95 | 486 | 203 | 0.20 / 557.44 | 2 | 3 |
2 | 7 | 2003.76 | 53 | 14.89 | 3121 | 2463 | 2.67 / 559.90 | 2 | 3 |
3 | 13 | 986.12 | 16 | 14.85 | 1761 | 418 | 3.08 / 560.32 | 2 | 3 |
4 | 13 | 414.40 | 16 | 14.95 | 953 | 228 | 3.31 / 560.55 | 2 | 4 |
5 | 13 | 68.80 | 16 | 15.03 | 430 | 103 | 3.42 / 560.65 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.01 | 309 | 765 | 4.18 / 561.41 | 2 | 4 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.52 | 28 | 14.97 | 495 | 207 | 0.21 / 553.36 | 2 | 3 |
2 | 7 | 2004.84 | 52 | 14.87 | 3123 | 2415 | 2.62 / 555.78 | 2 | 3 |
3 | 13 | 865.64 | 16 | 14.87 | 1583 | 377 | 3.00 / 556.16 | 2 | 3 |
4 | 13 | 442.00 | 16 | 14.96 | 991 | 237 | 3.24 / 556.39 | 2 | 4 |
5 | 13 | 69.88 | 16 | 15.03 | 412 | 99 | 3.34 / 556.49 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.01 | 299 | 741 | 4.08 / 557.23 | 2 | 5 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.80 | 28 | 14.95 | 495 | 207 | 0.21 / 549.23 | 3 | 3 |
2 | 7 | 2004.52 | 53 | 14.87 | 3115 | 2455 | 2.66 / 551.68 | 2 | 3 |
3 | 13 | 871.28 | 16 | 14.88 | 1595 | 380 | 3.04 / 552.06 | 2 | 4 |
4 | 13 | 443.16 | 16 | 14.95 | 993 | 238 | 3.28 / 552.30 | 2 | 3 |
5 | 13 | 79.36 | 16 | 15.04 | 441 | 106 | 3.39 / 552.41 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.01 | 303 | 750 | 4.14 / 553.16 | 2 | 5 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.96 | 28 | 14.96 | 493 | 207 | 0.21 / 545.07 | 3 | 3 |
2 | 7 | 2004.68 | 53 | 14.87 | 3118 | 2457 | 2.66 / 547.53 | 2 | 3 |
3 | 13 | 886.20 | 16 | 14.87 | 1615 | 384 | 3.05 / 547.91 | 2 | 4 |
4 | 13 | 462.48 | 16 | 14.95 | 1000 | 239 | 3.29 / 548.15 | 2 | 4 |
5 | 13 | 81.00 | 16 | 15.03 | 448 | 108 | 3.40 / 548.26 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.00 | 307 | 760 | 4.15 / 549.02 | 2 | 4 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.68 | 28 | 14.98 | 454 | 190 | 0.19 / 540.81 | 2 | 3 |
2 | 7 | 2005.40 | 53 | 14.89 | 3115 | 2458 | 2.65 / 543.27 | 2 | 3 |
3 | 13 | 991.08 | 16 | 14.86 | 1748 | 416 | 3.06 / 543.68 | 2 | 3 |
4 | 13 | 411.84 | 16 | 14.98 | 940 | 225 | 3.29 / 543.91 | 2 | 4 |
5 | 13 | 128.12 | 16 | 15.03 | 527 | 127 | 3.42 / 544.03 | 2 | 3 |
6 | 13 | 38.88 | 16 | 15.03 | 377 | 91 | 3.51 / 544.12 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.01 | 300 | 743 | 4.25 / 544.87 | 2 | 4 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.04 | 28 | 14.98 | 470 | 197 | 0.20 / 536.75 | 3 | 3 |
2 | 7 | 2002.00 | 53 | 14.89 | 3115 | 2458 | 2.66 / 539.21 | 2 | 3 |
3 | 13 | 989.84 | 16 | 14.86 | 1747 | 415 | 3.07 / 539.63 | 2 | 3 |
4 | 13 | 405.36 | 16 | 14.98 | 926 | 222 | 3.29 / 539.85 | 2 | 4 |
5 | 13 | 64.52 | 16 | 15.05 | 391 | 94 | 3.39 / 539.94 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.03 | 272 | 675 | 4.06 / 540.62 | 2 | 5 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.52 | 28 | 14.99 | 472 | 198 | 0.20 / 532.67 | 3 | 3 |
2 | 7 | 2005.04 | 53 | 14.87 | 3109 | 2450 | 2.65 / 535.12 | 2 | 3 |
3 | 13 | 862.56 | 16 | 14.88 | 1580 | 376 | 3.02 / 535.49 | 2 | 4 |
4 | 13 | 433.88 | 16 | 14.96 | 972 | 233 | 3.26 / 535.73 | 2 | 4 |
5 | 13 | 71.28 | 16 | 15.04 | 429 | 103 | 3.36 / 535.83 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.02 | 293 | 726 | 4.09 / 536.56 | 2 | 5 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.36 | 28 | 14.98 | 463 | 194 | 0.19 / 528.56 | 3 | 3 |
2 | 7 | 2007.36 | 53 | 14.88 | 3124 | 2464 | 2.66 / 531.02 | 2 | 3 |
3 | 13 | 998.88 | 16 | 14.86 | 1761 | 419 | 3.08 / 531.44 | 2 | 5 |
4 | 13 | 420.36 | 16 | 14.97 | 943 | 226 | 3.30 / 531.66 | 2 | 4 |
5 | 13 | 67.72 | 16 | 15.04 | 405 | 97 | 3.40 / 531.76 | 2 | 3 |
6 | 8 | -0.16 | 165 | 15.03 | 285 | 707 | 4.11 / 532.47 | 2 | 4 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 28 | 14.98 | 446 | 187 | 0.19 / 524.52 | 3 | 3 |
2 | 7 | 2003.40 | 52 | 14.89 | 3124 | 2419 | 2.61 / 526.94 | 2 | 3 |
3 | 13 | 870.08 | 16 | 14.88 | 1585 | 377 | 2.98 / 527.32 | 2 | 4 |
4 | 13 | 441.96 | 16 | 14.97 | 981 | 235 | 3.22 / 527.56 | 2 | 4 |
5 | 13 | 72.16 | 16 | 15.05 | 415 | 100 | 3.32 / 527.66 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.03 | 285 | 707 | 4.02 / 528.36 | 2 | 5 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 28 | 14.98 | 444 | 186 | 0.19 / 520.51 | 3 | 3 |
2 | 7 | 2004.12 | 52 | 14.90 | 3101 | 2403 | 2.59 / 522.91 | 2 | 3 |
3 | 13 | 882.00 | 16 | 14.88 | 1611 | 384 | 2.97 / 523.29 | 2 | 4 |
4 | 13 | 339.00 | 16 | 15.00 | 829 | 199 | 3.17 / 523.49 | 2 | 4 |
5 | 13 | 53.92 | 16 | 15.07 | 394 | 95 | 3.27 / 523.59 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.02 | 302 | 748 | 4.01 / 524.34 | 2 | 6 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 28 | 14.97 | 443 | 186 | 0.19 / 516.45 | 3 | 3 |
2 | 7 | 2005.32 | 53 | 14.89 | 3121 | 2463 | 2.65 / 518.91 | 2 | 3 |
3 | 13 | 871.72 | 16 | 14.88 | 1581 | 376 | 3.03 / 519.29 | 2 | 3 |
4 | 13 | 451.20 | 16 | 14.96 | 993 | 238 | 3.26 / 519.52 | 2 | 4 |
5 | 13 | 78.08 | 16 | 15.04 | 416 | 100 | 3.36 / 519.62 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.02 | 282 | 699 | 4.06 / 520.32 | 2 | 6 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.20 | 28 | 14.97 | 461 | 193 | 0.19 / 512.33 | 3 | 3 |
2 | 7 | 2004.40 | 53 | 14.88 | 3138 | 2475 | 2.67 / 514.80 | 2 | 3 |
3 | 13 | 995.96 | 16 | 14.86 | 1767 | 420 | 3.09 / 515.23 | 2 | 4 |
4 | 13 | 423.04 | 16 | 14.97 | 968 | 232 | 3.32 / 515.46 | 2 | 4 |
5 | 13 | 65.72 | 16 | 15.05 | 403 | 97 | 3.42 / 515.55 | 2 | 3 |
6 | 8 | -0.12 | 165 | 15.02 | 285 | 706 | 4.12 / 516.26 | 2 | 6 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 28 | 14.98 | 438 | 184 | 0.18 / 508.26 | 3 | 3 |
2 | 7 | 2003.32 | 53 | 14.89 | 3119 | 2461 | 2.65 / 510.72 | 2 | 3 |
3 | 13 | 976.72 | 16 | 14.87 | 1738 | 414 | 3.06 / 511.14 | 2 | 5 |
4 | 13 | 393.32 | 16 | 14.98 | 911 | 218 | 3.28 / 511.35 | 2 | 3 |
5 | 13 | 63.00 | 16 | 15.05 | 399 | 96 | 3.37 / 511.45 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.03 | 277 | 687 | 4.06 / 512.14 | 2 | 5 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 28 | 14.97 | 457 | 192 | 0.19 / 504.20 | 3 | 3 |
2 | 7 | 2003.00 | 53 | 14.88 | 3125 | 2464 | 2.66 / 506.67 | 2 | 3 |
3 | 13 | 969.68 | 16 | 14.87 | 1719 | 409 | 3.07 / 507.07 | 2 | 4 |
4 | 13 | 395.56 | 16 | 14.98 | 912 | 219 | 3.28 / 507.29 | 2 | 4 |
5 | 13 | 59.72 | 16 | 15.06 | 390 | 94 | 3.38 / 507.39 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.03 | 278 | 689 | 4.07 / 508.08 | 2 | 4 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 28 | 14.97 | 444 | 186 | 0.19 / 500.10 | 3 | 3 |
2 | 7 | 2008.72 | 52 | 14.89 | 3118 | 2414 | 2.60 / 502.51 | 2 | 3 |
3 | 13 | 980.72 | 16 | 14.86 | 1747 | 415 | 3.02 / 502.93 | 2 | 4 |
4 | 13 | 409.08 | 16 | 14.98 | 933 | 224 | 3.24 / 503.15 | 2 | 4 |
5 | 13 | 65.80 | 16 | 15.06 | 425 | 102 | 3.34 / 503.25 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.02 | 305 | 756 | 4.10 / 504.01 | 2 | 5 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 28 | 14.98 | 437 | 183 | 0.18 / 496.05 | 2 | 3 |
2 | 7 | 2005.00 | 53 | 14.88 | 3117 | 2458 | 2.64 / 498.51 | 2 | 3 |
3 | 13 | 874.28 | 16 | 14.89 | 1600 | 381 | 3.02 / 498.89 | 2 | 3 |
4 | 13 | 330.84 | 16 | 14.99 | 818 | 196 | 3.22 / 499.08 | 2 | 3 |
5 | 13 | 53.80 | 16 | 15.06 | 391 | 94 | 3.31 / 499.18 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.02 | 296 | 734 | 4.05 / 499.91 | 2 | 6 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 28 | 14.97 | 443 | 186 | 0.19 / 492.01 | 3 | 3 |
2 | 7 | 2003.16 | 53 | 14.88 | 3115 | 2457 | 2.64 / 494.47 | 2 | 3 |
3 | 13 | 869.20 | 16 | 14.89 | 1585 | 378 | 3.02 / 494.85 | 2 | 4 |
4 | 13 | 326.20 | 16 | 14.99 | 810 | 194 | 3.21 / 495.04 | 2 | 4 |
5 | 13 | 89.08 | 16 | 15.05 | 442 | 106 | 3.32 / 495.15 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.02 | 289 | 716 | 4.04 / 495.87 | 2 | 4 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 28 | 14.97 | 433 | 181 | 0.18 / 487.94 | 2 | 3 |
2 | 7 | 2004.36 | 53 | 14.88 | 3111 | 2453 | 2.63 / 490.39 | 2 | 3 |
3 | 13 | 989.32 | 16 | 14.85 | 1750 | 416 | 3.05 / 490.80 | 2 | 3 |
4 | 13 | 411.72 | 16 | 14.98 | 940 | 225 | 3.28 / 491.03 | 2 | 4 |
5 | 13 | 67.08 | 16 | 15.05 | 406 | 98 | 3.37 / 491.13 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.01 | 283 | 701 | 4.07 / 491.83 | 2 | 5 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 28 | 14.98 | 454 | 190 | 0.19 / 483.94 | 2 | 3 |
2 | 7 | 2006.40 | 53 | 14.89 | 3117 | 2460 | 2.65 / 486.40 | 2 | 3 |
3 | 13 | 879.08 | 16 | 14.88 | 1601 | 381 | 3.03 / 486.78 | 2 | 4 |
4 | 13 | 335.44 | 16 | 15.00 | 820 | 197 | 3.23 / 486.98 | 2 | 3 |
5 | 13 | 51.84 | 16 | 15.04 | 374 | 90 | 3.32 / 487.07 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.03 | 277 | 687 | 4.01 / 487.75 | 2 | 6 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.12 | 28 | 14.99 | 466 | 196 | 0.20 / 479.84 | 3 | 3 |
2 | 7 | 2004.56 | 53 | 14.90 | 3119 | 2463 | 2.66 / 482.30 | 2 | 3 |
3 | 13 | 869.64 | 16 | 14.89 | 1594 | 380 | 3.04 / 482.68 | 2 | 3 |
4 | 13 | 447.48 | 16 | 14.98 | 997 | 239 | 3.28 / 482.92 | 2 | 3 |
5 | 13 | 71.80 | 16 | 15.06 | 421 | 101 | 3.38 / 483.02 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.03 | 293 | 727 | 4.11 / 483.75 | 2 | 6 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.20 | 28 | 14.99 | 470 | 197 | 0.20 / 475.80 | 3 | 3 |
2 | 7 | 2003.28 | 52 | 14.91 | 3118 | 2417 | 2.61 / 478.22 | 2 | 2 |
3 | 13 | 877.76 | 16 | 14.91 | 1593 | 380 | 2.99 / 478.60 | 2 | 3 |
4 | 13 | 342.32 | 16 | 15.01 | 841 | 202 | 3.20 / 478.80 | 2 | 3 |
5 | 13 | 52.72 | 16 | 15.07 | 394 | 95 | 3.29 / 478.89 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.03 | 303 | 751 | 4.04 / 479.64 | 2 | 6 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.84 | 28 | 14.99 | 479 | 201 | 0.20 / 471.74 | 3 | 3 |
2 | 7 | 2004.80 | 52 | 14.91 | 3121 | 2420 | 2.62 / 474.16 | 2 | 3 |
3 | 13 | 869.68 | 16 | 14.90 | 1590 | 379 | 3.00 / 474.54 | 2 | 4 |
4 | 13 | 445.36 | 16 | 14.98 | 987 | 237 | 3.24 / 474.77 | 2 | 3 |
5 | 13 | 68.56 | 16 | 15.07 | 416 | 100 | 3.34 / 474.87 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.04 | 293 | 727 | 4.06 / 475.60 | 2 | 5 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.00 | 28 | 15.00 | 463 | 194 | 0.19 / 467.60 | 3 | 3 |
2 | 7 | 2003.44 | 53 | 14.90 | 3121 | 2465 | 2.66 / 470.07 | 2 | 3 |
3 | 13 | 992.16 | 16 | 14.87 | 1761 | 419 | 3.08 / 470.49 | 2 | 3 |
4 | 13 | 415.16 | 16 | 14.98 | 945 | 226 | 3.30 / 470.71 | 2 | 4 |
5 | 13 | 63.12 | 16 | 15.08 | 395 | 95 | 3.40 / 470.81 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.04 | 293 | 727 | 4.13 / 471.54 | 2 | 6 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.48 | 28 | 14.99 | 474 | 199 | 0.20 / 463.55 | 2 | 3 |
2 | 7 | 2006.48 | 52 | 14.90 | 3114 | 2413 | 2.61 / 465.96 | 2 | 3 |
3 | 13 | 989.36 | 16 | 14.89 | 1759 | 419 | 3.03 / 466.38 | 2 | 4 |
4 | 13 | 408.40 | 16 | 15.00 | 931 | 223 | 3.25 / 466.60 | 2 | 3 |
5 | 13 | 64.20 | 16 | 15.08 | 400 | 97 | 3.35 / 466.70 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.05 | 286 | 710 | 4.06 / 467.41 | 2 | 7 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.92 | 28 | 14.99 | 467 | 196 | 0.20 / 459.44 | 3 | 3 |
2 | 7 | 2004.76 | 53 | 14.91 | 3118 | 2464 | 2.66 / 461.91 | 2 | 2 |
3 | 13 | 862.60 | 16 | 14.91 | 1584 | 378 | 3.04 / 462.28 | 2 | 4 |
4 | 13 | 443.28 | 16 | 15.00 | 994 | 239 | 3.28 / 462.52 | 2 | 3 |
5 | 13 | 70.20 | 16 | 15.07 | 420 | 101 | 3.38 / 462.62 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.05 | 292 | 725 | 4.10 / 463.35 | 2 | 5 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.16 | 28 | 14.99 | 464 | 195 | 0.19 / 455.28 | 2 | 3 |
2 | 7 | 2008.20 | 53 | 14.90 | 3112 | 2458 | 2.65 / 457.74 | 2 | 3 |
3 | 13 | 872.68 | 16 | 14.90 | 1587 | 378 | 3.03 / 458.12 | 2 | 4 |
4 | 13 | 324.80 | 16 | 15.02 | 804 | 193 | 3.22 / 458.31 | 2 | 3 |
5 | 13 | 46.84 | 16 | 15.08 | 373 | 90 | 3.31 / 458.40 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.04 | 288 | 715 | 4.03 / 459.11 | 2 | 11 |
7 | 14 | 0.04 | 30 | 15.02 | 291 | 131 | 4.16 / 459.25 | 3 | 7 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.64 | 28 | 15.00 | 459 | 193 | 0.19 / 451.22 | 2 | 3 |
2 | 7 | 2007.32 | 53 | 14.90 | 3123 | 2466 | 2.66 / 453.69 | 2 | 3 |
3 | 13 | 875.88 | 16 | 14.90 | 1584 | 378 | 3.04 / 454.07 | 2 | 4 |
4 | 13 | 447.52 | 16 | 14.98 | 977 | 234 | 3.27 / 454.30 | 2 | 4 |
5 | 13 | 71.92 | 16 | 15.07 | 400 | 96 | 3.37 / 454.40 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.05 | 278 | 690 | 4.06 / 455.09 | 2 | 4 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.80 | 28 | 15.00 | 469 | 197 | 0.20 / 447.17 | 2 | 3 |
2 | 7 | 2005.96 | 53 | 14.91 | 3123 | 2468 | 2.66 / 449.63 | 2 | 3 |
3 | 13 | 871.72 | 16 | 14.91 | 1577 | 376 | 3.04 / 450.01 | 2 | 4 |
4 | 13 | 452.00 | 16 | 14.99 | 988 | 237 | 3.28 / 450.25 | 2 | 3 |
5 | 13 | 36.68 | 16 | 15.08 | 354 | 85 | 3.36 / 450.33 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.05 | 280 | 695 | 4.06 / 451.03 | 2 | 5 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.72 | 28 | 15.01 | 466 | 196 | 0.20 / 443.14 | 3 | 3 |
2 | 7 | 2009.40 | 53 | 14.90 | 3121 | 2465 | 2.66 / 445.60 | 2 | 3 |
3 | 13 | 877.76 | 16 | 14.91 | 1600 | 382 | 3.04 / 445.99 | 2 | 4 |
4 | 13 | 335.68 | 16 | 15.02 | 829 | 199 | 3.24 / 446.19 | 2 | 4 |
5 | 13 | 25.80 | 16 | 15.09 | 337 | 81 | 3.32 / 446.27 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.05 | 283 | 703 | 4.03 / 446.97 | 2 | 6 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.56 | 28 | 15.00 | 458 | 192 | 0.19 / 439.06 | 2 | 3 |
2 | 7 | 2003.56 | 53 | 14.91 | 3118 | 2464 | 2.66 / 441.53 | 2 | 3 |
3 | 13 | 979.44 | 16 | 14.89 | 1734 | 413 | 3.07 / 441.94 | 2 | 4 |
4 | 13 | 395.48 | 16 | 15.01 | 907 | 218 | 3.29 / 442.16 | 2 | 4 |
5 | 13 | 56.60 | 16 | 15.08 | 376 | 91 | 3.38 / 442.25 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.06 | 280 | 696 | 4.07 / 442.94 | 2 | 5 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.00 | 28 | 15.01 | 471 | 198 | 0.20 / 435.01 | 2 | 3 |
2 | 7 | 2003.60 | 53 | 14.90 | 3116 | 2461 | 2.66 / 437.47 | 2 | 3 |
3 | 13 | 864.64 | 16 | 14.92 | 1570 | 375 | 3.03 / 437.85 | 2 | 4 |
4 | 13 | 440.28 | 16 | 14.99 | 979 | 235 | 3.27 / 438.08 | 2 | 3 |
5 | 13 | 66.68 | 16 | 15.07 | 396 | 95 | 3.36 / 438.18 | 2 | 3 |
6 | 8 | -0.12 | 165 | 15.05 | 279 | 693 | 4.06 / 438.87 | 2 | 4 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.20 | 28 | 15.01 | 462 | 194 | 0.19 / 430.98 | 2 | 3 |
2 | 7 | 2002.44 | 53 | 14.92 | 3124 | 2470 | 2.66 / 433.45 | 2 | 3 |
3 | 13 | 877.64 | 16 | 14.92 | 1595 | 381 | 3.05 / 433.83 | 2 | 3 |
4 | 13 | 335.40 | 16 | 15.04 | 819 | 197 | 3.24 / 434.03 | 2 | 3 |
5 | 13 | 46.92 | 16 | 15.08 | 362 | 87 | 3.33 / 434.12 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.06 | 280 | 696 | 4.03 / 434.81 | 2 | 4 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 28 | 15.02 | 462 | 194 | 0.19 / 426.95 | 2 | 3 |
2 | 7 | 2003.88 | 52 | 14.91 | 3118 | 2417 | 2.61 / 429.37 | 2 | 3 |
3 | 13 | 863.20 | 16 | 14.92 | 1576 | 376 | 2.99 / 429.75 | 2 | 4 |
4 | 13 | 436.28 | 16 | 15.01 | 968 | 232 | 3.22 / 429.98 | 2 | 3 |
5 | 13 | 67.24 | 16 | 15.08 | 403 | 97 | 3.32 / 430.08 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.06 | 286 | 711 | 4.03 / 430.79 | 2 | 8 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.96 | 28 | 15.01 | 469 | 197 | 0.20 / 422.91 | 2 | 3 |
2 | 7 | 2002.60 | 53 | 14.91 | 3116 | 2462 | 2.66 / 425.38 | 2 | 3 |
3 | 13 | 861.60 | 16 | 14.93 | 1569 | 375 | 3.03 / 425.75 | 2 | 4 |
4 | 13 | 431.16 | 16 | 15.02 | 958 | 230 | 3.26 / 425.98 | 2 | 4 |
5 | 13 | 59.60 | 16 | 15.09 | 380 | 92 | 3.36 / 426.07 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.06 | 277 | 688 | 4.04 / 426.76 | 2 | 4 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.32 | 28 | 15.02 | 476 | 200 | 0.20 / 418.83 | 2 | 3 |
2 | 7 | 2003.56 | 53 | 14.91 | 3114 | 2461 | 2.66 / 421.29 | 2 | 3 |
3 | 13 | 967.36 | 16 | 14.91 | 1720 | 410 | 3.07 / 421.70 | 2 | 4 |
4 | 13 | 388.40 | 16 | 15.02 | 907 | 218 | 3.29 / 421.92 | 2 | 3 |
5 | 13 | 56.88 | 16 | 15.09 | 391 | 94 | 3.38 / 422.01 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.06 | 284 | 706 | 4.09 / 422.72 | 2 | 6 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.00 | 28 | 15.03 | 447 | 188 | 0.19 / 414.84 | 2 | 3 |
2 | 7 | 2003.40 | 53 | 14.91 | 3122 | 2467 | 2.66 / 417.30 | 2 | 3 |
3 | 13 | 862.36 | 16 | 14.92 | 1582 | 378 | 3.03 / 417.68 | 2 | 3 |
4 | 13 | 433.12 | 16 | 15.01 | 977 | 235 | 3.27 / 417.92 | 2 | 4 |
5 | 8 | 0.00 | 165 | 15.07 | 286 | 711 | 3.98 / 418.63 | 2 | 6 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.92 | 27 | 15.01 | 471 | 191 | 0.19 / 410.85 | 2 | 3 |
2 | 7 | 2004.44 | 53 | 14.92 | 3118 | 2466 | 2.66 / 413.31 | 2 | 3 |
3 | 13 | 980.60 | 16 | 14.91 | 1742 | 416 | 3.07 / 413.73 | 2 | 4 |
4 | 13 | 402.04 | 16 | 15.02 | 917 | 220 | 3.29 / 413.95 | 2 | 3 |
5 | 8 | 0.20 | 165 | 15.08 | 281 | 699 | 3.99 / 414.65 | 2 | 4 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.96 | 27 | 15.01 | 455 | 184 | 0.18 / 406.80 | 3 | 3 |
2 | 7 | 2009.92 | 53 | 14.92 | 3123 | 2470 | 2.65 / 409.27 | 2 | 3 |
3 | 13 | 872.48 | 16 | 14.92 | 1594 | 381 | 3.03 / 409.65 | 2 | 3 |
4 | 13 | 332.68 | 16 | 15.04 | 820 | 197 | 3.23 / 409.84 | 2 | 3 |
5 | 13 | 45.48 | 16 | 15.10 | 372 | 90 | 3.32 / 409.93 | 2 | 3 |
6 | 8 | -0.08 | 165 | 15.06 | 291 | 723 | 4.04 / 410.66 | 2 | 7 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.52 | 27 | 15.02 | 476 | 193 | 0.19 / 402.75 | 2 | 3 |
2 | 7 | 2005.80 | 53 | 14.91 | 3118 | 2464 | 2.66 / 405.21 | 2 | 3 |
3 | 13 | 865.08 | 16 | 14.91 | 1576 | 376 | 3.03 / 405.59 | 2 | 3 |
4 | 13 | 436.64 | 16 | 15.00 | 972 | 233 | 3.27 / 405.82 | 2 | 3 |
5 | 13 | 34.12 | 16 | 15.10 | 352 | 85 | 3.35 / 405.91 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.06 | 284 | 706 | 4.06 / 406.61 | 2 | 5 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 27 | 15.03 | 461 | 187 | 0.19 / 398.68 | 2 | 3 |
2 | 7 | 2003.00 | 53 | 14.93 | 3124 | 2472 | 2.66 / 401.16 | 2 | 3 |
3 | 13 | 862.72 | 16 | 14.93 | 1579 | 377 | 3.04 / 401.53 | 2 | 3 |
4 | 13 | 433.00 | 16 | 15.02 | 965 | 232 | 3.27 / 401.76 | 2 | 3 |
5 | 13 | 31.40 | 16 | 15.10 | 346 | 84 | 3.35 / 401.85 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.07 | 284 | 706 | 4.06 / 402.55 | 2 | 5 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.08 | 27 | 15.02 | 463 | 188 | 0.19 / 394.76 | 3 | 3 |
2 | 7 | 2005.00 | 53 | 14.91 | 3113 | 2460 | 2.65 / 397.22 | 2 | 3 |
3 | 13 | 855.76 | 16 | 14.94 | 1560 | 373 | 3.02 / 397.59 | 2 | 3 |
4 | 13 | 307.76 | 16 | 15.05 | 775 | 187 | 3.21 / 397.77 | 2 | 3 |
5 | 8 | 0.16 | 165 | 15.08 | 290 | 722 | 3.93 / 398.50 | 2 | 5 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 27 | 15.01 | 489 | 198 | 0.20 / 390.66 | 2 | 3 |
2 | 7 | 2003.08 | 53 | 14.93 | 3112 | 2462 | 2.66 / 393.12 | 2 | 3 |
3 | 13 | 986.28 | 16 | 14.91 | 1747 | 417 | 3.08 / 393.54 | 2 | 4 |
4 | 13 | 407.36 | 16 | 15.03 | 930 | 224 | 3.30 / 393.76 | 2 | 3 |
5 | 13 | 58.92 | 16 | 15.10 | 383 | 93 | 3.39 / 393.86 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.07 | 286 | 711 | 4.10 / 394.57 | 2 | 5 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.36 | 27 | 15.02 | 473 | 192 | 0.19 / 386.51 | 3 | 3 |
2 | 7 | 2005.16 | 53 | 14.93 | 3127 | 2474 | 2.67 / 388.99 | 2 | 3 |
3 | 13 | 872.12 | 16 | 14.93 | 1594 | 381 | 3.05 / 389.37 | 2 | 3 |
4 | 13 | 440.88 | 16 | 15.01 | 983 | 236 | 3.28 / 389.60 | 2 | 3 |
5 | 13 | 71.48 | 16 | 15.09 | 442 | 107 | 3.39 / 389.71 | 2 | 3 |
6 | 8 | -0.12 | 165 | 15.06 | 303 | 753 | 4.14 / 390.46 | 2 | 7 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 27 | 15.01 | 453 | 184 | 0.18 / 382.43 | 2 | 3 |
2 | 7 | 2002.68 | 53 | 14.92 | 3098 | 2450 | 2.63 / 384.88 | 2 | 3 |
3 | 13 | 975.68 | 16 | 14.90 | 1730 | 412 | 3.05 / 385.29 | 2 | 4 |
4 | 13 | 400.32 | 16 | 15.01 | 915 | 220 | 3.27 / 385.51 | 2 | 3 |
5 | 13 | 59.24 | 16 | 15.09 | 395 | 95 | 3.36 / 385.60 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.06 | 288 | 716 | 4.08 / 386.32 | 2 | 9 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.56 | 27 | 15.00 | 491 | 199 | 0.20 / 378.31 | 2 | 3 |
2 | 7 | 2004.36 | 53 | 14.92 | 3130 | 2475 | 2.67 / 380.78 | 2 | 3 |
3 | 13 | 978.04 | 16 | 14.90 | 1742 | 415 | 3.09 / 381.20 | 2 | 3 |
4 | 13 | 395.00 | 16 | 15.01 | 915 | 220 | 3.31 / 381.42 | 2 | 3 |
5 | 13 | 62.32 | 16 | 15.09 | 402 | 97 | 3.41 / 381.51 | 2 | 3 |
6 | 8 | -0.08 | 165 | 15.06 | 294 | 731 | 4.14 / 382.24 | 2 | 3 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 27 | 15.01 | 467 | 189 | 0.19 / 374.19 | 3 | 3 |
2 | 7 | 2003.16 | 53 | 14.91 | 3104 | 2453 | 2.64 / 376.64 | 2 | 3 |
3 | 13 | 869.40 | 16 | 14.92 | 1595 | 381 | 3.02 / 377.02 | 2 | 4 |
4 | 13 | 438.20 | 16 | 15.00 | 985 | 236 | 3.26 / 377.26 | 2 | 3 |
5 | 13 | 67.24 | 16 | 15.09 | 416 | 100 | 3.36 / 377.36 | 2 | 3 |
6 | 8 | -0.08 | 165 | 15.06 | 301 | 748 | 4.11 / 378.11 | 2 | 5 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 27 | 15.01 | 474 | 192 | 0.19 / 370.15 | 3 | 3 |
2 | 7 | 2003.52 | 53 | 14.92 | 3109 | 2458 | 2.65 / 372.60 | 2 | 3 |
3 | 13 | 864.52 | 16 | 14.93 | 1591 | 380 | 3.03 / 372.98 | 2 | 3 |
4 | 13 | 321.08 | 16 | 15.04 | 807 | 194 | 3.22 / 373.18 | 2 | 3 |
5 | 13 | 49.24 | 16 | 15.09 | 384 | 93 | 3.32 / 373.27 | 2 | 3 |
6 | 8 | -0.08 | 165 | 15.07 | 293 | 729 | 4.05 / 374.00 | 2 | 6 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.44 | 27 | 15.01 | 459 | 186 | 0.19 / 365.99 | 2 | 3 |
2 | 7 | 2006.32 | 53 | 14.91 | 3121 | 2466 | 2.65 / 368.45 | 2 | 3 |
3 | 13 | 991.76 | 16 | 14.90 | 1748 | 417 | 3.07 / 368.87 | 2 | 4 |
4 | 13 | 403.52 | 16 | 15.02 | 922 | 222 | 3.29 / 369.09 | 2 | 3 |
5 | 13 | 64.00 | 16 | 15.09 | 418 | 101 | 3.39 / 369.19 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.05 | 307 | 762 | 4.15 / 369.95 | 2 | 5 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.20 | 27 | 15.01 | 469 | 190 | 0.19 / 361.93 | 2 | 3 |
2 | 7 | 2002.32 | 52 | 14.93 | 3122 | 2424 | 2.61 / 364.35 | 2 | 3 |
3 | 13 | 984.12 | 16 | 14.90 | 1745 | 416 | 3.03 / 364.77 | 2 | 3 |
4 | 13 | 407.72 | 16 | 15.01 | 923 | 222 | 3.25 / 364.99 | 2 | 3 |
5 | 13 | 64.00 | 16 | 15.09 | 400 | 97 | 3.35 / 365.09 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.06 | 287 | 713 | 4.06 / 365.80 | 2 | 4 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.20 | 27 | 15.01 | 487 | 197 | 0.20 / 357.84 | 3 | 3 |
2 | 7 | 2005.92 | 53 | 14.92 | 3125 | 2471 | 2.67 / 360.31 | 2 | 3 |
3 | 13 | 863.80 | 16 | 14.92 | 1578 | 377 | 3.05 / 360.68 | 2 | 4 |
4 | 13 | 432.76 | 16 | 15.01 | 966 | 232 | 3.28 / 360.92 | 2 | 3 |
5 | 13 | 66.76 | 16 | 15.09 | 406 | 98 | 3.38 / 361.01 | 2 | 3 |
6 | 8 | -0.16 | 165 | 15.06 | 291 | 723 | 4.10 / 361.74 | 2 | 4 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 27 | 15.02 | 442 | 179 | 0.18 / 353.73 | 2 | 3 |
2 | 7 | 2004.60 | 53 | 14.93 | 3117 | 2466 | 2.65 / 356.20 | 2 | 3 |
3 | 13 | 865.60 | 16 | 14.93 | 1577 | 377 | 3.02 / 356.58 | 2 | 4 |
4 | 13 | 436.44 | 16 | 15.01 | 977 | 235 | 3.26 / 356.81 | 2 | 3 |
5 | 13 | 67.60 | 16 | 15.09 | 413 | 100 | 3.36 / 356.91 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.06 | 293 | 728 | 4.08 / 357.64 | 2 | 5 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.96 | 27 | 15.02 | 473 | 192 | 0.19 / 349.65 | 3 | 3 |
2 | 7 | 2006.32 | 53 | 14.92 | 3120 | 2467 | 2.66 / 352.11 | 2 | 3 |
3 | 13 | 977.48 | 16 | 14.92 | 1731 | 413 | 3.07 / 352.53 | 2 | 4 |
4 | 13 | 399.48 | 16 | 15.03 | 917 | 221 | 3.29 / 352.75 | 2 | 3 |
5 | 13 | 61.96 | 16 | 15.10 | 393 | 95 | 3.39 / 352.84 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.07 | 286 | 711 | 4.10 / 353.55 | 2 | 4 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.64 | 28 | 15.01 | 447 | 188 | 0.19 / 345.64 | 3 | 3 |
2 | 7 | 2004.56 | 52 | 14.93 | 3120 | 2422 | 2.61 / 348.06 | 2 | 3 |
3 | 13 | 869.84 | 16 | 14.94 | 1585 | 379 | 2.99 / 348.44 | 2 | 4 |
4 | 13 | 330.72 | 16 | 15.04 | 817 | 197 | 3.19 / 348.64 | 2 | 3 |
5 | 13 | 49.04 | 16 | 15.11 | 377 | 91 | 3.28 / 348.73 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.07 | 293 | 729 | 4.01 / 349.46 | 2 | 5 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 28 | 15.02 | 446 | 188 | 0.19 / 341.57 | 3 | 3 |
2 | 7 | 2004.48 | 52 | 14.93 | 3127 | 2428 | 2.62 / 344.00 | 2 | 3 |
3 | 13 | 870.04 | 16 | 14.93 | 1595 | 381 | 3.00 / 344.38 | 2 | 3 |
4 | 13 | 442.64 | 16 | 15.01 | 984 | 236 | 3.23 / 344.62 | 2 | 4 |
5 | 13 | 67.40 | 16 | 15.10 | 412 | 100 | 3.33 / 344.72 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.06 | 295 | 733 | 4.07 / 345.45 | 2 | 5 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.48 | 27 | 15.01 | 470 | 190 | 0.19 / 337.50 | 2 | 3 |
2 | 7 | 2003.80 | 53 | 14.92 | 3100 | 2451 | 2.64 / 339.95 | 2 | 3 |
3 | 13 | 858.56 | 16 | 14.93 | 1564 | 374 | 3.02 / 340.32 | 2 | 3 |
4 | 13 | 438.28 | 16 | 15.02 | 980 | 236 | 3.25 / 340.56 | 2 | 3 |
5 | 13 | 65.16 | 16 | 15.09 | 407 | 98 | 3.35 / 340.65 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.07 | 294 | 731 | 4.08 / 341.39 | 2 | 5 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.00 | 27 | 15.02 | 476 | 193 | 0.19 / 333.43 | 3 | 3 |
2 | 7 | 2005.24 | 53 | 14.93 | 3110 | 2461 | 2.65 / 335.89 | 2 | 3 |
3 | 13 | 856.80 | 16 | 14.95 | 1566 | 375 | 3.03 / 336.27 | 2 | 4 |
4 | 13 | 322.72 | 16 | 15.06 | 798 | 192 | 3.22 / 336.46 | 2 | 3 |
5 | 13 | 48.84 | 16 | 15.09 | 389 | 94 | 3.31 / 336.55 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.06 | 302 | 750 | 4.07 / 337.31 | 2 | 5 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.44 | 27 | 15.02 | 476 | 193 | 0.19 / 329.34 | 3 | 3 |
2 | 7 | 2003.04 | 53 | 14.93 | 3120 | 2469 | 2.66 / 331.81 | 2 | 3 |
3 | 13 | 860.84 | 16 | 14.94 | 1587 | 379 | 3.04 / 332.19 | 2 | 3 |
4 | 13 | 440.08 | 16 | 15.01 | 980 | 235 | 3.28 / 332.42 | 2 | 3 |
5 | 13 | 40.68 | 16 | 15.10 | 368 | 89 | 3.37 / 332.51 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.07 | 293 | 729 | 4.09 / 333.24 | 2 | 6 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.08 | 27 | 15.02 | 469 | 190 | 0.19 / 325.15 | 2 | 3 |
2 | 7 | 2007.68 | 53 | 14.92 | 3122 | 2469 | 2.66 / 327.62 | 2 | 3 |
3 | 13 | 865.16 | 16 | 14.95 | 1581 | 378 | 3.04 / 328.00 | 2 | 4 |
4 | 13 | 324.08 | 16 | 15.05 | 804 | 194 | 3.23 / 328.19 | 2 | 3 |
5 | 13 | 45.00 | 16 | 15.10 | 373 | 90 | 3.32 / 328.28 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.07 | 293 | 729 | 4.05 / 329.01 | 2 | 5 |
7 | 14 | 0.12 | 30 | 15.05 | 297 | 134 | 4.18 / 329.15 | 3 | 5 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.16 | 27 | 15.03 | 483 | 196 | 0.20 / 321.13 | 2 | 3 |
2 | 7 | 2004.48 | 52 | 14.92 | 3125 | 2424 | 2.62 / 323.55 | 2 | 3 |
3 | 13 | 850.68 | 16 | 14.95 | 1558 | 373 | 2.99 / 323.93 | 2 | 4 |
4 | 13 | 426.08 | 16 | 15.02 | 961 | 231 | 3.22 / 324.16 | 2 | 4 |
5 | 13 | 33.60 | 16 | 15.11 | 348 | 84 | 3.31 / 324.24 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.07 | 290 | 721 | 4.03 / 324.96 | 2 | 5 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.80 | 27 | 15.03 | 486 | 197 | 0.20 / 317.00 | 2 | 3 |
2 | 7 | 2003.44 | 53 | 14.93 | 3119 | 2468 | 2.67 / 319.47 | 2 | 3 |
3 | 13 | 960.64 | 16 | 14.93 | 1725 | 412 | 3.08 / 319.88 | 2 | 4 |
4 | 13 | 388.40 | 16 | 15.04 | 917 | 221 | 3.30 / 320.10 | 2 | 4 |
5 | 13 | 33.08 | 16 | 15.11 | 355 | 86 | 3.38 / 320.19 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.07 | 300 | 746 | 4.13 / 320.93 | 2 | 5 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.84 | 27 | 15.02 | 489 | 198 | 0.20 / 312.87 | 2 | 3 |
2 | 7 | 2004.44 | 53 | 14.93 | 3121 | 2470 | 2.67 / 315.34 | 2 | 3 |
3 | 13 | 979.16 | 16 | 14.91 | 1740 | 415 | 3.08 / 315.75 | 2 | 3 |
4 | 13 | 384.76 | 16 | 15.05 | 903 | 217 | 3.30 / 315.97 | 2 | 4 |
5 | 13 | 54.64 | 16 | 15.11 | 398 | 96 | 3.40 / 316.06 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.08 | 297 | 739 | 4.14 / 316.80 | 2 | 5 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.00 | 27 | 15.04 | 480 | 195 | 0.19 / 308.72 | 3 | 3 |
2 | 7 | 2003.00 | 53 | 14.93 | 3122 | 2470 | 2.67 / 311.19 | 2 | 3 |
3 | 13 | 966.84 | 16 | 14.92 | 1723 | 411 | 3.08 / 311.60 | 2 | 4 |
4 | 13 | 394.12 | 16 | 15.05 | 910 | 219 | 3.30 / 311.82 | 2 | 4 |
5 | 13 | 55.24 | 16 | 15.11 | 398 | 96 | 3.39 / 311.92 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.08 | 302 | 751 | 4.14 / 312.67 | 2 | 5 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.60 | 27 | 15.04 | 477 | 194 | 0.19 / 304.67 | 2 | 3 |
2 | 7 | 2006.88 | 53 | 14.94 | 3134 | 2482 | 2.68 / 307.15 | 2 | 3 |
3 | 13 | 866.64 | 16 | 14.95 | 1580 | 378 | 3.05 / 307.53 | 2 | 3 |
4 | 13 | 317.32 | 16 | 15.07 | 801 | 193 | 3.25 / 307.72 | 2 | 3 |
5 | 13 | 40.08 | 16 | 15.12 | 365 | 88 | 3.33 / 307.81 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.08 | 288 | 717 | 4.05 / 308.52 | 2 | 5 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.40 | 27 | 15.03 | 478 | 194 | 0.19 / 300.56 | 2 | 3 |
2 | 7 | 2004.52 | 53 | 14.94 | 3128 | 2477 | 2.67 / 303.03 | 2 | 3 |
3 | 13 | 987.64 | 16 | 14.93 | 1749 | 418 | 3.09 / 303.45 | 2 | 4 |
4 | 13 | 398.96 | 16 | 15.04 | 920 | 221 | 3.31 / 303.67 | 2 | 3 |
5 | 13 | 31.16 | 16 | 15.11 | 348 | 84 | 3.39 / 303.76 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.09 | 288 | 717 | 4.11 / 304.47 | 2 | 4 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.20 | 27 | 15.03 | 473 | 192 | 0.19 / 296.43 | 2 | 3 |
2 | 7 | 2002.80 | 53 | 14.94 | 3116 | 2467 | 2.66 / 298.89 | 2 | 3 |
3 | 13 | 981.96 | 16 | 14.93 | 1752 | 419 | 3.08 / 299.31 | 2 | 4 |
4 | 13 | 401.48 | 16 | 15.05 | 932 | 224 | 3.30 / 299.54 | 2 | 3 |
5 | 13 | 31.00 | 16 | 15.12 | 350 | 85 | 3.39 / 299.62 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.08 | 298 | 741 | 4.13 / 300.36 | 2 | 4 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.40 | 27 | 15.04 | 485 | 197 | 0.20 / 292.24 | 2 | 3 |
2 | 7 | 2004.24 | 53 | 14.94 | 3134 | 2482 | 2.68 / 294.73 | 2 | 3 |
3 | 13 | 986.00 | 16 | 14.93 | 1756 | 419 | 3.10 / 295.15 | 2 | 3 |
4 | 13 | 389.40 | 16 | 15.05 | 911 | 219 | 3.32 / 295.36 | 2 | 4 |
5 | 13 | 52.92 | 16 | 15.11 | 402 | 97 | 3.41 / 295.46 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.08 | 310 | 771 | 4.19 / 296.23 | 2 | 7 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.80 | 27 | 15.04 | 503 | 204 | 0.20 / 288.17 | 2 | 3 |
2 | 7 | 2004.12 | 52 | 14.94 | 3115 | 2420 | 2.62 / 290.59 | 2 | 3 |
3 | 13 | 984.24 | 16 | 14.93 | 1757 | 420 | 3.04 / 291.00 | 2 | 4 |
4 | 13 | 401.12 | 16 | 15.05 | 934 | 225 | 3.27 / 291.23 | 2 | 3 |
5 | 13 | 26.76 | 16 | 15.13 | 344 | 83 | 3.35 / 291.31 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.09 | 295 | 735 | 4.09 / 292.05 | 2 | 5 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.52 | 27 | 15.05 | 484 | 197 | 0.20 / 284.07 | 2 | 3 |
2 | 7 | 2003.32 | 52 | 14.96 | 3121 | 2428 | 2.62 / 286.50 | 2 | 3 |
3 | 13 | 854.80 | 16 | 14.97 | 1576 | 377 | 3.00 / 286.87 | 2 | 3 |
4 | 13 | 422.64 | 16 | 15.05 | 952 | 229 | 3.23 / 287.10 | 2 | 3 |
5 | 13 | 28.04 | 16 | 15.13 | 364 | 88 | 3.32 / 287.19 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.09 | 309 | 769 | 4.09 / 287.96 | 2 | 6 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.40 | 27 | 15.05 | 503 | 204 | 0.20 / 280.04 | 2 | 3 |
2 | 7 | 2003.08 | 53 | 14.95 | 3118 | 2471 | 2.67 / 282.51 | 2 | 3 |
3 | 13 | 979.40 | 16 | 14.94 | 1746 | 417 | 3.09 / 282.92 | 2 | 3 |
4 | 13 | 395.84 | 16 | 15.05 | 916 | 221 | 3.31 / 283.14 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.11 | 292 | 728 | 4.04 / 283.87 | 2 | 4 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.28 | 27 | 15.05 | 466 | 189 | 0.19 / 275.99 | 2 | 3 |
2 | 7 | 2006.68 | 53 | 14.95 | 3122 | 2474 | 2.66 / 278.47 | 2 | 3 |
3 | 13 | 847.72 | 16 | 14.97 | 1566 | 375 | 3.04 / 278.84 | 2 | 4 |
4 | 13 | 424.84 | 16 | 15.05 | 976 | 235 | 3.27 / 279.08 | 2 | 3 |
5 | 8 | 0.12 | 165 | 15.11 | 303 | 755 | 4.03 / 279.83 | 2 | 3 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.00 | 27 | 15.06 | 481 | 196 | 0.20 / 271.89 | 2 | 3 |
2 | 7 | 2002.80 | 52 | 14.94 | 3115 | 2420 | 2.62 / 274.31 | 2 | 3 |
3 | 13 | 975.84 | 16 | 14.94 | 1735 | 415 | 3.03 / 274.73 | 2 | 3 |
4 | 13 | 388.84 | 16 | 15.05 | 910 | 219 | 3.25 / 274.95 | 2 | 4 |
5 | 13 | 117.16 | 16 | 15.10 | 492 | 119 | 3.37 / 275.07 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.09 | 296 | 737 | 4.11 / 275.80 | 2 | 5 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.40 | 27 | 15.08 | 485 | 197 | 0.20 / 267.89 | 2 | 3 |
2 | 7 | 2007.76 | 53 | 14.94 | 3122 | 2472 | 2.67 / 270.36 | 2 | 3 |
3 | 13 | 864.20 | 16 | 14.97 | 1572 | 377 | 3.05 / 270.74 | 2 | 4 |
4 | 13 | 433.20 | 16 | 15.06 | 970 | 234 | 3.28 / 270.97 | 2 | 4 |
5 | 8 | 0.04 | 165 | 15.12 | 292 | 728 | 4.01 / 271.70 | 2 | 5 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 27 | 15.07 | 478 | 194 | 0.19 / 263.93 | 2 | 3 |
2 | 7 | 2003.72 | 53 | 14.96 | 3124 | 2477 | 2.67 / 266.41 | 2 | 3 |
3 | 13 | 853.84 | 16 | 14.98 | 1565 | 375 | 3.05 / 266.78 | 2 | 4 |
4 | 13 | 307.84 | 16 | 15.09 | 779 | 188 | 3.23 / 266.97 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.11 | 288 | 718 | 3.95 / 267.69 | 2 | 4 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.08 | 27 | 15.08 | 490 | 200 | 0.20 / 259.93 | 2 | 3 |
2 | 7 | 2003.80 | 53 | 14.96 | 3120 | 2474 | 2.67 / 262.41 | 2 | 3 |
3 | 13 | 850.68 | 16 | 14.99 | 1552 | 372 | 3.05 / 262.78 | 2 | 3 |
4 | 13 | 423.88 | 16 | 15.07 | 961 | 232 | 3.28 / 263.01 | 2 | 3 |
5 | 8 | 0.16 | 165 | 15.12 | 291 | 726 | 4.00 / 263.74 | 2 | 5 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.24 | 27 | 15.07 | 472 | 192 | 0.19 / 256.01 | 3 | 3 |
2 | 7 | 2003.12 | 52 | 14.95 | 3113 | 2420 | 2.61 / 258.43 | 2 | 3 |
3 | 13 | 862.40 | 16 | 14.99 | 1576 | 378 | 2.99 / 258.81 | 2 | 3 |
4 | 13 | 319.40 | 16 | 15.10 | 792 | 191 | 3.18 / 259.00 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.13 | 292 | 729 | 3.91 / 259.73 | 2 | 4 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.96 | 27 | 15.08 | 472 | 192 | 0.19 / 251.94 | 3 | 3 |
2 | 7 | 2003.80 | 53 | 14.96 | 3120 | 2474 | 2.67 / 254.42 | 2 | 3 |
3 | 13 | 854.76 | 16 | 14.99 | 1558 | 374 | 3.04 / 254.79 | 2 | 3 |
4 | 13 | 424.84 | 16 | 15.06 | 962 | 232 | 3.27 / 255.02 | 2 | 3 |
5 | 13 | 15.56 | 16 | 15.16 | 322 | 78 | 3.35 / 255.10 | 2 | 3 |
6 | 8 | -0.08 | 165 | 15.12 | 290 | 723 | 4.07 / 255.82 | 2 | 7 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 27 | 15.10 | 459 | 187 | 0.19 / 247.89 | 2 | 3 |
2 | 7 | 2006.16 | 53 | 14.96 | 3127 | 2479 | 2.67 / 250.37 | 2 | 3 |
3 | 13 | 865.20 | 16 | 14.99 | 1589 | 381 | 3.05 / 250.75 | 2 | 4 |
4 | 13 | 314.28 | 16 | 15.10 | 796 | 192 | 3.24 / 250.94 | 2 | 3 |
5 | 13 | 45.40 | 16 | 15.15 | 376 | 91 | 3.33 / 251.03 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.12 | 287 | 716 | 4.05 / 251.75 | 2 | 7 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 27 | 15.09 | 461 | 188 | 0.19 / 243.89 | 3 | 3 |
2 | 7 | 2003.08 | 53 | 14.96 | 3120 | 2474 | 2.66 / 246.36 | 2 | 3 |
3 | 13 | 976.52 | 16 | 14.97 | 1722 | 412 | 3.07 / 246.78 | 2 | 4 |
4 | 13 | 384.44 | 16 | 15.09 | 891 | 215 | 3.29 / 246.99 | 2 | 4 |
5 | 8 | 0.04 | 165 | 15.14 | 285 | 712 | 4.00 / 247.70 | 2 | 5 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.60 | 27 | 15.09 | 463 | 189 | 0.19 / 239.80 | 2 | 3 |
2 | 7 | 2003.88 | 53 | 14.97 | 3116 | 2472 | 2.66 / 242.28 | 2 | 3 |
3 | 13 | 857.08 | 16 | 15.00 | 1561 | 375 | 3.04 / 242.65 | 2 | 4 |
4 | 13 | 422.68 | 16 | 15.08 | 955 | 230 | 3.27 / 242.88 | 2 | 4 |
5 | 13 | 29.00 | 16 | 15.17 | 342 | 83 | 3.35 / 242.96 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.14 | 295 | 737 | 4.09 / 243.70 | 2 | 5 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.80 | 27 | 15.08 | 481 | 196 | 0.20 / 235.66 | 2 | 3 |
2 | 7 | 2006.12 | 53 | 14.97 | 3126 | 2480 | 2.68 / 238.14 | 2 | 3 |
3 | 13 | 979.44 | 16 | 14.98 | 1755 | 421 | 3.10 / 238.56 | 2 | 4 |
4 | 13 | 395.40 | 16 | 15.11 | 916 | 221 | 3.32 / 238.78 | 2 | 3 |
5 | 13 | 57.44 | 16 | 15.17 | 397 | 96 | 3.41 / 238.88 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.14 | 294 | 734 | 4.15 / 239.62 | 2 | 6 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.88 | 27 | 15.10 | 479 | 195 | 0.20 / 231.67 | 2 | 3 |
2 | 7 | 2003.04 | 52 | 14.95 | 3121 | 2426 | 2.62 / 234.10 | 2 | 3 |
3 | 13 | 845.64 | 16 | 15.00 | 1559 | 374 | 3.00 / 234.47 | 2 | 3 |
4 | 13 | 294.64 | 16 | 15.12 | 760 | 184 | 3.18 / 234.66 | 2 | 4 |
5 | 13 | 37.24 | 16 | 15.18 | 356 | 86 | 3.27 / 234.74 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.14 | 290 | 724 | 3.99 / 235.47 | 2 | 5 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.92 | 27 | 15.11 | 480 | 196 | 0.20 / 227.56 | 3 | 3 |
2 | 7 | 2003.60 | 53 | 14.98 | 3125 | 2481 | 2.68 / 230.05 | 2 | 3 |
3 | 13 | 854.16 | 16 | 15.02 | 1561 | 375 | 3.05 / 230.42 | 2 | 3 |
4 | 13 | 413.12 | 16 | 15.11 | 936 | 226 | 3.28 / 230.65 | 2 | 3 |
5 | 13 | 58.56 | 16 | 15.18 | 391 | 95 | 3.37 / 230.74 | 2 | 3 |
6 | 8 | -0.12 | 165 | 15.14 | 294 | 734 | 4.11 / 231.48 | 2 | 4 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.68 | 27 | 15.12 | 474 | 194 | 0.19 / 223.53 | 2 | 3 |
2 | 7 | 2002.56 | 52 | 14.98 | 3121 | 2431 | 2.62 / 225.97 | 2 | 3 |
3 | 13 | 863.84 | 16 | 15.02 | 1572 | 378 | 3.00 / 226.34 | 2 | 4 |
4 | 13 | 320.68 | 16 | 15.14 | 802 | 194 | 3.20 / 226.54 | 2 | 3 |
5 | 13 | 83.96 | 16 | 15.18 | 434 | 105 | 3.30 / 226.64 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.16 | 290 | 725 | 4.03 / 227.37 | 2 | 5 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.56 | 27 | 15.11 | 474 | 193 | 0.19 / 219.49 | 3 | 3 |
2 | 7 | 2002.96 | 53 | 14.98 | 3105 | 2465 | 2.66 / 221.95 | 2 | 3 |
3 | 13 | 845.24 | 16 | 15.03 | 1560 | 375 | 3.03 / 222.33 | 2 | 3 |
4 | 13 | 297.72 | 16 | 15.15 | 776 | 188 | 3.22 / 222.52 | 2 | 3 |
5 | 13 | 42.00 | 16 | 15.20 | 367 | 89 | 3.31 / 222.61 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.17 | 294 | 736 | 4.05 / 223.34 | 2 | 4 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 27 | 15.13 | 450 | 184 | 0.18 / 215.36 | 2 | 3 |
2 | 7 | 2006.52 | 53 | 14.98 | 3121 | 2478 | 2.66 / 217.84 | 2 | 3 |
3 | 13 | 974.36 | 16 | 15.00 | 1738 | 417 | 3.08 / 218.26 | 2 | 3 |
4 | 13 | 381.08 | 16 | 15.13 | 891 | 216 | 3.29 / 218.47 | 2 | 3 |
5 | 13 | 54.84 | 16 | 15.20 | 390 | 95 | 3.39 / 218.57 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.16 | 291 | 728 | 4.12 / 219.29 | 2 | 4 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.24 | 27 | 15.12 | 471 | 192 | 0.19 / 211.31 | 2 | 3 |
2 | 7 | 2003.64 | 53 | 14.98 | 3126 | 2482 | 2.67 / 213.79 | 2 | 3 |
3 | 13 | 854.12 | 16 | 15.03 | 1567 | 377 | 3.05 / 214.17 | 2 | 3 |
4 | 13 | 294.44 | 16 | 15.17 | 775 | 188 | 3.24 / 214.35 | 2 | 3 |
5 | 13 | 42.56 | 16 | 15.21 | 375 | 91 | 3.33 / 214.45 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.18 | 292 | 731 | 4.06 / 215.18 | 2 | 4 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.16 | 27 | 15.13 | 469 | 192 | 0.19 / 207.26 | 2 | 3 |
2 | 7 | 2006.72 | 53 | 15.00 | 3134 | 2492 | 2.68 / 209.75 | 2 | 3 |
3 | 13 | 851.12 | 16 | 15.04 | 1569 | 378 | 3.06 / 210.13 | 2 | 3 |
4 | 13 | 296.16 | 16 | 15.16 | 768 | 186 | 3.25 / 210.32 | 2 | 3 |
5 | 13 | 43.72 | 16 | 15.21 | 363 | 88 | 3.34 / 210.41 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.17 | 283 | 708 | 4.04 / 211.11 | 2 | 5 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.12 | 27 | 15.15 | 464 | 190 | 0.19 / 203.18 | 2 | 3 |
2 | 7 | 2002.64 | 53 | 14.97 | 3116 | 2472 | 2.66 / 205.66 | 2 | 3 |
3 | 13 | 952.60 | 16 | 15.02 | 1703 | 409 | 3.07 / 206.07 | 2 | 4 |
4 | 13 | 366.28 | 16 | 15.15 | 867 | 210 | 3.28 / 206.28 | 2 | 3 |
5 | 13 | 54.04 | 16 | 15.22 | 379 | 92 | 3.37 / 206.37 | 2 | 3 |
6 | 8 | -0.08 | 165 | 15.18 | 281 | 704 | 4.08 / 207.07 | 2 | 6 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.56 | 27 | 15.14 | 467 | 191 | 0.19 / 199.15 | 2 | 3 |
2 | 7 | 2004.32 | 53 | 15.00 | 3118 | 2479 | 2.67 / 201.63 | 2 | 3 |
3 | 13 | 856.96 | 16 | 15.05 | 1571 | 378 | 3.05 / 202.01 | 2 | 4 |
4 | 13 | 313.44 | 16 | 15.18 | 786 | 191 | 3.24 / 202.20 | 2 | 3 |
5 | 13 | 44.76 | 16 | 15.23 | 365 | 89 | 3.33 / 202.29 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.19 | 281 | 704 | 4.03 / 202.99 | 2 | 4 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.08 | 27 | 15.14 | 443 | 181 | 0.18 / 195.05 | 3 | 3 |
2 | 7 | 2007.88 | 53 | 14.99 | 3125 | 2483 | 2.66 / 197.53 | 2 | 3 |
3 | 13 | 847.48 | 16 | 15.06 | 1543 | 372 | 3.04 / 197.90 | 2 | 4 |
4 | 13 | 422.04 | 16 | 15.14 | 948 | 230 | 3.27 / 198.13 | 2 | 3 |
5 | 13 | 58.32 | 16 | 15.22 | 397 | 97 | 3.36 / 198.23 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.19 | 293 | 734 | 4.10 / 198.96 | 2 | 4 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 27 | 15.15 | 460 | 188 | 0.19 / 191.04 | 3 | 3 |
2 | 7 | 2005.80 | 52 | 14.99 | 3129 | 2439 | 2.63 / 193.48 | 2 | 3 |
3 | 13 | 844.20 | 16 | 15.06 | 1547 | 373 | 3.00 / 193.85 | 2 | 3 |
4 | 13 | 290.16 | 16 | 15.18 | 760 | 185 | 3.18 / 194.03 | 2 | 3 |
5 | 13 | 72.76 | 16 | 15.22 | 422 | 103 | 3.29 / 194.14 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.19 | 291 | 729 | 4.02 / 194.87 | 2 | 4 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.56 | 27 | 15.15 | 468 | 191 | 0.19 / 186.99 | 2 | 3 |
2 | 7 | 2002.24 | 53 | 15.00 | 3111 | 2473 | 2.66 / 189.46 | 2 | 3 |
3 | 13 | 854.92 | 16 | 15.05 | 1575 | 379 | 3.04 / 189.84 | 2 | 3 |
4 | 13 | 310.16 | 16 | 15.18 | 782 | 190 | 3.23 / 190.03 | 2 | 3 |
5 | 13 | 38.72 | 16 | 15.23 | 366 | 89 | 3.32 / 190.12 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.19 | 290 | 727 | 4.05 / 190.85 | 2 | 4 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.88 | 27 | 15.16 | 487 | 199 | 0.20 / 183.03 | 2 | 3 |
2 | 7 | 2003.84 | 52 | 14.99 | 3095 | 2412 | 2.61 / 185.44 | 2 | 3 |
3 | 13 | 851.64 | 16 | 15.05 | 1559 | 375 | 2.99 / 185.82 | 2 | 3 |
4 | 13 | 298.00 | 16 | 15.17 | 764 | 185 | 3.17 / 186.00 | 2 | 3 |
5 | 13 | 42.72 | 16 | 15.22 | 368 | 90 | 3.26 / 186.09 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.19 | 281 | 704 | 3.97 / 186.80 | 2 | 5 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.36 | 27 | 15.16 | 484 | 198 | 0.20 / 178.89 | 3 | 3 |
2 | 7 | 2001.64 | 53 | 15.01 | 3126 | 2487 | 2.68 / 181.38 | 2 | 3 |
3 | 13 | 960.44 | 16 | 15.03 | 1727 | 415 | 3.10 / 181.79 | 2 | 4 |
4 | 13 | 371.52 | 16 | 15.17 | 884 | 215 | 3.31 / 182.01 | 2 | 3 |
5 | 13 | 49.44 | 16 | 15.23 | 388 | 95 | 3.41 / 182.10 | 2 | 3 |
6 | 8 | 0.16 | 165 | 15.20 | 291 | 730 | 4.14 / 182.83 | 2 | 4 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.64 | 27 | 15.16 | 468 | 192 | 0.19 / 174.80 | 2 | 3 |
2 | 7 | 2002.80 | 53 | 15.00 | 3126 | 2485 | 2.68 / 177.29 | 2 | 3 |
3 | 13 | 845.36 | 16 | 15.07 | 1556 | 375 | 3.05 / 177.66 | 2 | 3 |
4 | 13 | 302.16 | 16 | 15.20 | 787 | 191 | 3.24 / 177.86 | 2 | 3 |
5 | 13 | 37.96 | 16 | 15.26 | 366 | 89 | 3.33 / 177.95 | 2 | 3 |
6 | 8 | -0.08 | 165 | 15.21 | 298 | 748 | 4.08 / 178.69 | 2 | 7 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.12 | 27 | 15.16 | 476 | 195 | 0.19 / 170.76 | 2 | 3 |
2 | 7 | 2003.24 | 52 | 14.99 | 3119 | 2431 | 2.63 / 173.19 | 2 | 3 |
3 | 13 | 835.72 | 16 | 15.07 | 1544 | 372 | 3.00 / 173.56 | 2 | 4 |
4 | 13 | 409.68 | 16 | 15.15 | 944 | 229 | 3.23 / 173.79 | 2 | 3 |
5 | 13 | 34.40 | 16 | 15.23 | 359 | 87 | 3.31 / 173.88 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.20 | 292 | 732 | 4.05 / 174.61 | 2 | 5 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.76 | 27 | 15.15 | 497 | 203 | 0.20 / 166.63 | 3 | 3 |
2 | 7 | 2003.04 | 53 | 15.00 | 3117 | 2478 | 2.68 / 169.11 | 2 | 3 |
3 | 13 | 967.80 | 16 | 15.04 | 1720 | 414 | 3.10 / 169.52 | 2 | 4 |
4 | 13 | 376.36 | 16 | 15.17 | 898 | 218 | 3.31 / 169.74 | 2 | 3 |
5 | 13 | 32.00 | 16 | 15.24 | 361 | 88 | 3.40 / 169.83 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.20 | 295 | 740 | 4.14 / 170.57 | 2 | 5 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.84 | 27 | 15.16 | 498 | 204 | 0.20 / 162.48 | 2 | 3 |
2 | 7 | 2007.56 | 53 | 14.99 | 3129 | 2486 | 2.69 / 164.96 | 2 | 3 |
3 | 13 | 851.28 | 16 | 15.06 | 1581 | 381 | 3.07 / 165.35 | 2 | 4 |
4 | 13 | 426.28 | 16 | 15.15 | 981 | 238 | 3.31 / 165.58 | 2 | 4 |
5 | 13 | 33.20 | 16 | 15.24 | 364 | 89 | 3.40 / 165.67 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.20 | 300 | 752 | 4.15 / 166.42 | 2 | 3 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.96 | 27 | 15.16 | 502 | 205 | 0.21 / 158.37 | 3 | 3 |
2 | 7 | 2005.48 | 52 | 15.01 | 3132 | 2445 | 2.65 / 160.81 | 2 | 3 |
3 | 13 | 955.36 | 16 | 15.04 | 1713 | 412 | 3.06 / 161.22 | 2 | 4 |
4 | 13 | 370.80 | 16 | 15.18 | 890 | 216 | 3.28 / 161.44 | 2 | 3 |
5 | 13 | 28.24 | 16 | 15.25 | 352 | 86 | 3.36 / 161.52 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.21 | 299 | 750 | 4.11 / 162.27 | 2 | 5 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.76 | 27 | 15.16 | 497 | 203 | 0.20 / 154.18 | 2 | 3 |
2 | 7 | 2006.60 | 53 | 15.00 | 3129 | 2488 | 2.69 / 156.67 | 2 | 3 |
3 | 13 | 966.56 | 16 | 15.05 | 1729 | 416 | 3.11 / 157.09 | 2 | 5 |
4 | 13 | 371.08 | 16 | 15.17 | 901 | 219 | 3.33 / 157.31 | 2 | 4 |
5 | 13 | 28.04 | 16 | 15.25 | 355 | 87 | 3.41 / 157.39 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.21 | 306 | 768 | 4.18 / 158.16 | 2 | 5 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 27 | 15.16 | 482 | 197 | 0.20 / 150.02 | 2 | 3 |
2 | 7 | 2002.04 | 53 | 15.01 | 3122 | 2484 | 2.68 / 152.50 | 2 | 3 |
3 | 13 | 965.84 | 16 | 15.04 | 1737 | 418 | 3.10 / 152.92 | 2 | 4 |
4 | 13 | 371.52 | 16 | 15.19 | 894 | 217 | 3.32 / 153.14 | 2 | 3 |
5 | 13 | 26.44 | 16 | 15.25 | 348 | 85 | 3.40 / 153.22 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.21 | 301 | 755 | 4.16 / 153.98 | 2 | 3 |
Average= | 3.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.60 | 27 | 15.17 | 484 | 198 | 0.20 / 145.85 | 2 | 3 |
2 | 7 | 2003.12 | 53 | 15.01 | 3116 | 2479 | 2.68 / 148.33 | 2 | 2 |
3 | 13 | 851.24 | 16 | 15.08 | 1560 | 376 | 3.05 / 148.70 | 2 | 3 |
4 | 13 | 411.56 | 16 | 15.17 | 945 | 229 | 3.28 / 148.93 | 2 | 3 |
5 | 13 | 29.40 | 16 | 15.25 | 374 | 91 | 3.37 / 149.02 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.21 | 319 | 801 | 4.17 / 149.82 | 2 | 7 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.20 | 27 | 15.17 | 474 | 194 | 0.19 / 141.74 | 2 | 3 |
2 | 7 | 2002.00 | 53 | 15.00 | 3106 | 2469 | 2.66 / 144.21 | 2 | 3 |
3 | 13 | 846.08 | 16 | 15.08 | 1556 | 375 | 3.04 / 144.59 | 2 | 3 |
4 | 13 | 411.36 | 16 | 15.17 | 949 | 230 | 3.27 / 144.82 | 2 | 3 |
5 | 13 | 27.00 | 16 | 15.25 | 350 | 85 | 3.35 / 144.90 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.22 | 297 | 746 | 4.10 / 145.65 | 2 | 4 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.48 | 27 | 15.19 | 491 | 201 | 0.20 / 137.73 | 2 | 3 |
2 | 7 | 2001.84 | 52 | 15.02 | 3125 | 2441 | 2.64 / 140.17 | 2 | 3 |
3 | 13 | 846.16 | 16 | 15.10 | 1561 | 377 | 3.02 / 140.54 | 2 | 3 |
4 | 13 | 296.68 | 16 | 15.21 | 773 | 188 | 3.21 / 140.73 | 2 | 3 |
5 | 13 | 18.04 | 16 | 15.26 | 328 | 80 | 3.29 / 140.81 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.22 | 293 | 736 | 4.02 / 141.55 | 2 | 4 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.88 | 27 | 15.19 | 497 | 204 | 0.20 / 133.65 | 2 | 3 |
2 | 7 | 2007.12 | 53 | 15.01 | 3128 | 2488 | 2.69 / 136.14 | 2 | 3 |
3 | 13 | 959.88 | 16 | 15.06 | 1731 | 417 | 3.11 / 136.55 | 2 | 3 |
4 | 13 | 372.24 | 16 | 15.18 | 890 | 216 | 3.33 / 136.77 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.23 | 300 | 754 | 4.08 / 137.52 | 2 | 3 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.12 | 27 | 15.20 | 474 | 195 | 0.19 / 129.63 | 2 | 3 |
2 | 7 | 2002.36 | 53 | 15.03 | 3121 | 2486 | 2.68 / 132.11 | 2 | 3 |
3 | 13 | 853.60 | 16 | 15.11 | 1565 | 378 | 3.06 / 132.49 | 2 | 3 |
4 | 13 | 298.16 | 16 | 15.21 | 775 | 189 | 3.25 / 132.68 | 2 | 4 |
5 | 8 | 0.12 | 165 | 15.24 | 305 | 767 | 4.01 / 133.45 | 2 | 6 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.04 | 27 | 15.19 | 472 | 194 | 0.19 / 125.68 | 2 | 3 |
2 | 7 | 2002.92 | 52 | 15.01 | 3109 | 2427 | 2.62 / 128.11 | 2 | 3 |
3 | 13 | 840.04 | 16 | 15.09 | 1544 | 373 | 2.99 / 128.48 | 2 | 3 |
4 | 13 | 403.44 | 16 | 15.18 | 927 | 225 | 3.22 / 128.70 | 2 | 3 |
5 | 8 | -0.04 | 165 | 15.23 | 289 | 726 | 3.94 / 129.43 | 2 | 6 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.48 | 27 | 15.20 | 477 | 196 | 0.20 / 121.71 | 2 | 3 |
2 | 7 | 2002.08 | 53 | 15.02 | 3119 | 2483 | 2.68 / 124.19 | 2 | 3 |
3 | 13 | 845.08 | 16 | 15.09 | 1555 | 375 | 3.05 / 124.56 | 2 | 3 |
4 | 13 | 290.44 | 16 | 15.22 | 761 | 185 | 3.24 / 124.75 | 2 | 3 |
5 | 8 | 0.16 | 165 | 15.24 | 293 | 737 | 3.98 / 125.49 | 2 | 3 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 27 | 15.20 | 466 | 191 | 0.19 / 117.67 | 2 | 3 |
2 | 7 | 2003.08 | 53 | 15.02 | 3114 | 2479 | 2.67 / 120.15 | 2 | 3 |
3 | 13 | 966.24 | 16 | 15.08 | 1719 | 415 | 3.08 / 120.57 | 2 | 4 |
4 | 13 | 367.12 | 16 | 15.20 | 874 | 213 | 3.30 / 120.78 | 2 | 3 |
5 | 8 | 0.08 | 165 | 15.24 | 290 | 729 | 4.03 / 121.51 | 2 | 6 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.72 | 27 | 15.21 | 485 | 199 | 0.20 / 113.54 | 2 | 3 |
2 | 7 | 2002.76 | 53 | 15.03 | 3121 | 2486 | 2.69 / 116.03 | 2 | 3 |
3 | 13 | 959.20 | 16 | 15.07 | 1714 | 413 | 3.10 / 116.44 | 2 | 4 |
4 | 13 | 363.52 | 16 | 15.20 | 872 | 212 | 3.31 / 116.65 | 2 | 3 |
5 | 13 | 57.08 | 16 | 15.27 | 397 | 97 | 3.41 / 116.75 | 2 | 3 |
6 | 8 | 0.20 | 165 | 15.24 | 292 | 734 | 4.14 / 117.48 | 2 | 7 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.92 | 27 | 15.19 | 485 | 199 | 0.20 / 109.42 | 3 | 3 |
2 | 7 | 2001.80 | 53 | 15.04 | 3123 | 2489 | 2.69 / 111.91 | 2 | 3 |
3 | 13 | 836.64 | 16 | 15.12 | 1544 | 374 | 3.06 / 112.29 | 2 | 4 |
4 | 13 | 406.84 | 16 | 15.20 | 934 | 227 | 3.29 / 112.51 | 2 | 3 |
5 | 13 | 30.52 | 16 | 15.28 | 350 | 86 | 3.37 / 112.60 | 2 | 3 |
6 | 8 | -0.08 | 165 | 15.25 | 295 | 742 | 4.12 / 113.34 | 2 | 5 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.08 | 27 | 15.19 | 494 | 203 | 0.20 / 105.43 | 2 | 3 |
2 | 7 | 2007.48 | 53 | 15.03 | 3113 | 2480 | 2.68 / 107.91 | 2 | 3 |
3 | 13 | 852.00 | 16 | 15.09 | 1568 | 379 | 3.06 / 108.28 | 2 | 4 |
4 | 13 | 301.32 | 16 | 15.21 | 793 | 193 | 3.25 / 108.48 | 2 | 3 |
5 | 8 | -0.04 | 165 | 15.25 | 297 | 747 | 4.00 / 109.22 | 2 | 4 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 27 | 15.20 | 464 | 190 | 0.19 / 101.33 | 2 | 3 |
2 | 7 | 2006.72 | 53 | 15.03 | 3122 | 2487 | 2.68 / 103.82 | 2 | 3 |
3 | 13 | 848.44 | 16 | 15.10 | 1556 | 376 | 3.05 / 104.20 | 2 | 3 |
4 | 13 | 296.88 | 16 | 15.22 | 773 | 188 | 3.24 / 104.38 | 2 | 3 |
5 | 13 | 41.28 | 16 | 15.27 | 374 | 91 | 3.33 / 104.48 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.24 | 297 | 747 | 4.08 / 105.22 | 2 | 6 |
Average= | 3.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.32 | 27 | 15.23 | 472 | 194 | 0.19 / 97.36 | 3 | 3 |
2 | 7 | 2006.12 | 53 | 15.03 | 3123 | 2488 | 2.68 / 99.85 | 2 | 3 |
3 | 13 | 846.32 | 16 | 15.11 | 1555 | 376 | 3.06 / 100.22 | 2 | 3 |
4 | 13 | 295.56 | 16 | 15.22 | 787 | 192 | 3.25 / 100.41 | 2 | 3 |
5 | 8 | 0.28 | 165 | 15.25 | 290 | 730 | 3.98 / 101.14 | 2 | 4 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 27 | 15.22 | 446 | 183 | 0.18 / 93.39 | 3 | 3 |
2 | 7 | 2002.52 | 53 | 15.06 | 3129 | 2498 | 2.68 / 95.89 | 2 | 3 |
3 | 13 | 838.60 | 16 | 15.13 | 1537 | 372 | 3.05 / 96.26 | 2 | 3 |
4 | 13 | 286.44 | 16 | 15.24 | 751 | 183 | 3.24 / 96.44 | 2 | 3 |
5 | 8 | 0.16 | 165 | 15.26 | 287 | 723 | 3.96 / 97.16 | 2 | 4 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.92 | 27 | 15.22 | 487 | 200 | 0.20 / 89.32 | 2 | 3 |
2 | 7 | 2007.28 | 52 | 15.06 | 3121 | 2444 | 2.64 / 91.77 | 2 | 2 |
3 | 13 | 965.48 | 16 | 15.10 | 1720 | 416 | 3.06 / 92.18 | 2 | 3 |
4 | 13 | 263.68 | 16 | 15.26 | 719 | 176 | 3.24 / 92.36 | 2 | 3 |
5 | 8 | -0.08 | 165 | 15.27 | 285 | 718 | 3.95 / 93.07 | 2 | 4 |
6 | 14 | -0.08 | 30 | 15.24 | 286 | 131 | 4.08 / 93.21 | 2 | 6 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.16 | 27 | 15.21 | 483 | 198 | 0.20 / 85.37 | 3 | 3 |
2 | 7 | 2007.92 | 52 | 15.06 | 3119 | 2443 | 2.64 / 87.81 | 2 | 2 |
3 | 13 | 855.24 | 16 | 15.12 | 1570 | 380 | 3.02 / 88.19 | 2 | 3 |
4 | 13 | 301.48 | 16 | 15.25 | 782 | 191 | 3.21 / 88.38 | 2 | 3 |
5 | 8 | 0.32 | 165 | 15.27 | 293 | 738 | 3.95 / 89.12 | 2 | 5 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.48 | 27 | 15.22 | 468 | 192 | 0.19 / 81.35 | 2 | 3 |
2 | 7 | 2007.64 | 52 | 15.05 | 3128 | 2448 | 2.64 / 83.80 | 2 | 2 |
3 | 13 | 847.88 | 16 | 15.13 | 1555 | 376 | 3.02 / 84.17 | 2 | 3 |
4 | 13 | 289.72 | 16 | 15.25 | 757 | 185 | 3.20 / 84.36 | 2 | 3 |
5 | 13 | 17.72 | 16 | 15.31 | 327 | 80 | 3.28 / 84.44 | 2 | 2 |
6 | 8 | -0.04 | 165 | 15.26 | 292 | 735 | 4.02 / 85.17 | 2 | 6 |
Average= | 3.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.20 | 27 | 15.23 | 473 | 195 | 0.19 / 77.23 | 3 | 3 |
2 | 7 | 2005.60 | 53 | 15.05 | 3118 | 2487 | 2.68 / 79.72 | 2 | 2 |
3 | 13 | 839.84 | 16 | 15.13 | 1551 | 375 | 3.06 / 80.09 | 2 | 3 |
4 | 13 | 403.36 | 16 | 15.22 | 929 | 226 | 3.28 / 80.32 | 2 | 3 |
5 | 13 | 55.00 | 16 | 15.28 | 389 | 95 | 3.38 / 80.41 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.25 | 295 | 742 | 4.12 / 81.15 | 2 | 5 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 27 | 15.23 | 479 | 197 | 0.20 / 73.15 | 3 | 3 |
2 | 7 | 2002.16 | 53 | 15.05 | 3123 | 2491 | 2.69 / 75.64 | 2 | 3 |
3 | 13 | 830.92 | 16 | 15.14 | 1537 | 372 | 3.06 / 76.01 | 2 | 3 |
4 | 13 | 273.88 | 16 | 15.26 | 740 | 181 | 3.24 / 76.19 | 2 | 3 |
5 | 13 | 66.20 | 16 | 15.30 | 413 | 101 | 3.34 / 76.29 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.27 | 295 | 743 | 4.09 / 77.03 | 2 | 5 |
Average= | 3.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.56 | 27 | 15.22 | 472 | 194 | 0.19 / 68.90 | 2 | 3 |
2 | 7 | 2003.88 | 53 | 15.07 | 3117 | 2490 | 2.68 / 71.39 | 2 | 3 |
3 | 13 | 840.68 | 16 | 15.14 | 1556 | 377 | 3.06 / 71.77 | 2 | 3 |
4 | 13 | 279.24 | 16 | 15.26 | 754 | 184 | 3.24 / 71.95 | 2 | 3 |
5 | 13 | 69.72 | 16 | 15.29 | 419 | 103 | 3.35 / 72.06 | 2 | 3 |
6 | 8 | 0.24 | 165 | 15.27 | 300 | 756 | 4.10 / 72.81 | 2 | 5 |
7 | 14 | 0.24 | 30 | 15.25 | 300 | 137 | 4.24 / 72.95 | 3 | 7 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.36 | 27 | 15.22 | 487 | 200 | 0.20 / 64.73 | 3 | 3 |
2 | 7 | 2008.52 | 53 | 15.05 | 3133 | 2499 | 2.70 / 67.23 | 2 | 2 |
3 | 13 | 964.60 | 16 | 15.10 | 1726 | 417 | 3.12 / 67.65 | 2 | 3 |
4 | 13 | 370.48 | 16 | 15.23 | 887 | 216 | 3.33 / 67.86 | 2 | 3 |
5 | 13 | 47.12 | 16 | 15.29 | 391 | 96 | 3.43 / 67.96 | 2 | 3 |
6 | 8 | -0.08 | 165 | 15.26 | 298 | 750 | 4.18 / 68.71 | 2 | 4 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.32 | 27 | 15.22 | 475 | 195 | 0.20 / 60.66 | 2 | 3 |
2 | 7 | 2004.00 | 53 | 15.06 | 3119 | 2490 | 2.68 / 63.15 | 2 | 2 |
3 | 13 | 839.64 | 16 | 15.13 | 1550 | 375 | 3.06 / 63.53 | 2 | 3 |
4 | 13 | 281.04 | 16 | 15.26 | 744 | 182 | 3.24 / 63.71 | 2 | 3 |
5 | 13 | 33.72 | 16 | 15.30 | 355 | 87 | 3.33 / 63.79 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.27 | 292 | 736 | 4.06 / 64.53 | 2 | 4 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.48 | 27 | 15.23 | 477 | 196 | 0.20 / 56.62 | 3 | 3 |
2 | 7 | 2006.16 | 52 | 15.07 | 3127 | 2450 | 2.65 / 59.08 | 2 | 2 |
3 | 13 | 827.64 | 16 | 15.14 | 1530 | 371 | 3.02 / 59.45 | 2 | 3 |
4 | 13 | 273.84 | 16 | 15.26 | 738 | 180 | 3.20 / 59.63 | 2 | 3 |
5 | 13 | 34.92 | 16 | 15.30 | 367 | 90 | 3.29 / 59.72 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.26 | 298 | 750 | 4.04 / 60.47 | 2 | 4 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.24 | 27 | 15.22 | 477 | 196 | 0.20 / 52.48 | 3 | 3 |
2 | 7 | 2007.36 | 53 | 15.09 | 3124 | 2498 | 2.69 / 54.98 | 2 | 2 |
3 | 13 | 959.68 | 16 | 15.12 | 1711 | 414 | 3.11 / 55.40 | 2 | 3 |
4 | 13 | 357.28 | 16 | 15.24 | 862 | 210 | 3.32 / 55.61 | 2 | 3 |
5 | 13 | 50.44 | 16 | 15.29 | 381 | 93 | 3.41 / 55.70 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.28 | 289 | 729 | 4.14 / 56.43 | 2 | 5 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.96 | 26 | 15.23 | 473 | 187 | 0.19 / 48.41 | 3 | 3 |
2 | 7 | 2004.28 | 53 | 15.07 | 3115 | 2488 | 2.68 / 50.90 | 2 | 2 |
3 | 13 | 839.08 | 16 | 15.15 | 1551 | 376 | 3.05 / 51.28 | 2 | 3 |
4 | 13 | 286.72 | 16 | 15.27 | 754 | 184 | 3.24 / 51.46 | 2 | 3 |
5 | 13 | 37.48 | 16 | 15.31 | 361 | 88 | 3.32 / 51.55 | 2 | 3 |
6 | 8 | -0.04 | 165 | 15.28 | 293 | 739 | 4.06 / 52.29 | 2 | 4 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.68 | 26 | 15.22 | 489 | 194 | 0.19 / 44.29 | 2 | 3 |
2 | 7 | 2002.24 | 53 | 15.09 | 3121 | 2496 | 2.69 / 46.79 | 2 | 2 |
3 | 13 | 960.28 | 16 | 15.12 | 1728 | 418 | 3.11 / 47.21 | 2 | 3 |
4 | 13 | 255.16 | 16 | 15.28 | 715 | 175 | 3.28 / 47.38 | 2 | 3 |
5 | 13 | 56.16 | 16 | 15.32 | 398 | 98 | 3.38 / 47.48 | 2 | 3 |
6 | 8 | 0.12 | 165 | 15.29 | 296 | 747 | 4.13 / 48.23 | 2 | 4 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.60 | 26 | 15.22 | 495 | 196 | 0.20 / 40.19 | 2 | 3 |
2 | 7 | 2007.00 | 53 | 15.07 | 3128 | 2498 | 2.69 / 42.69 | 2 | 2 |
3 | 13 | 836.00 | 16 | 15.14 | 1552 | 376 | 3.07 / 43.06 | 2 | 3 |
4 | 13 | 281.92 | 16 | 15.26 | 758 | 185 | 3.26 / 43.25 | 2 | 3 |
5 | 13 | 36.32 | 16 | 15.30 | 370 | 91 | 3.35 / 43.34 | 2 | 2 |
6 | 8 | 0.00 | 165 | 15.26 | 302 | 760 | 4.11 / 44.10 | 2 | 6 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.84 | 26 | 15.23 | 459 | 182 | 0.18 / 36.09 | 3 | 3 |
2 | 7 | 2004.88 | 53 | 15.08 | 3120 | 2494 | 2.68 / 38.58 | 2 | 2 |
3 | 13 | 838.00 | 16 | 15.15 | 1552 | 376 | 3.05 / 38.96 | 2 | 3 |
4 | 13 | 286.08 | 16 | 15.27 | 764 | 187 | 3.24 / 39.14 | 2 | 3 |
5 | 13 | 36.20 | 16 | 15.31 | 370 | 91 | 3.33 / 39.23 | 2 | 3 |
6 | 8 | -0.08 | 165 | 15.27 | 301 | 758 | 4.09 / 39.99 | 2 | 5 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.76 | 26 | 15.22 | 493 | 195 | 0.20 / 32.00 | 3 | 3 |
2 | 7 | 2002.04 | 53 | 15.07 | 3123 | 2494 | 2.69 / 34.49 | 2 | 2 |
3 | 13 | 829.92 | 16 | 15.16 | 1547 | 375 | 3.06 / 34.87 | 2 | 3 |
4 | 13 | 275.40 | 16 | 15.28 | 754 | 184 | 3.25 / 35.05 | 2 | 3 |
5 | 13 | 33.36 | 16 | 15.33 | 369 | 91 | 3.34 / 35.14 | 2 | 3 |
6 | 8 | 0.00 | 165 | 15.28 | 303 | 764 | 4.10 / 35.91 | 2 | 6 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 26 | 15.22 | 462 | 183 | 0.18 / 27.89 | 2 | 3 |
2 | 7 | 2001.84 | 53 | 15.09 | 3112 | 2489 | 2.67 / 30.38 | 2 | 2 |
3 | 13 | 832.88 | 16 | 15.16 | 1555 | 377 | 3.05 / 30.75 | 2 | 3 |
4 | 13 | 277.24 | 16 | 15.27 | 759 | 185 | 3.23 / 30.94 | 2 | 3 |
5 | 13 | 35.48 | 16 | 15.30 | 369 | 90 | 3.32 / 31.03 | 2 | 3 |
6 | 8 | 0.08 | 165 | 15.27 | 306 | 771 | 4.10 / 31.80 | 2 | 4 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 26 | 15.23 | 474 | 188 | 0.19 / 23.70 | 2 | 3 |
2 | 7 | 2003.64 | 53 | 15.09 | 3119 | 2494 | 2.68 / 26.19 | 2 | 2 |
3 | 13 | 833.48 | 18 | 15.14 | 1551 | 423 | 3.10 / 26.62 | 2 | 3 |
4 | 13 | 258.60 | 18 | 15.27 | 726 | 200 | 3.30 / 26.82 | 2 | 3 |
5 | 13 | 21.68 | 18 | 15.32 | 354 | 98 | 3.40 / 26.91 | 2 | 3 |
6 | 8 | -0.12 | 165 | 15.28 | 314 | 792 | 4.19 / 27.71 | 2 | 5 |
Average= | 3.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.04 | 25 | 15.23 | 502 | 191 | 0.19 / 19.45 | 3 | 3 |
2 | 10 | 1018.24 | 2 | 15.25 | 1864 | 57 | 0.25 / 19.51 | 2 | 3 |
3 | 7 | 2003.68 | 53 | 15.09 | 3126 | 2500 | 2.75 / 22.01 | 2 | 2 |
4 | 13 | 830.84 | 18 | 15.16 | 1551 | 423 | 3.17 / 22.43 | 2 | 3 |
5 | 13 | 253.52 | 18 | 15.28 | 721 | 198 | 3.37 / 22.63 | 2 | 3 |
6 | 13 | 22.84 | 18 | 15.32 | 357 | 98 | 3.47 / 22.73 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.28 | 312 | 787 | 4.25 / 23.51 | 2 | 5 |
Average= | 3.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.72 | 25 | 15.23 | 499 | 190 | 0.19 / 15.29 | 2 | 3 |
2 | 3 | 1017.40 | 1 | 15.30 | 1875 | 29 | 0.22 / 15.32 | 2 | 2 |
3 | 7 | 2005.12 | 52 | 15.10 | 3121 | 2451 | 2.67 / 17.77 | 2 | 2 |
4 | 13 | 816.48 | 18 | 15.16 | 1536 | 419 | 3.09 / 18.19 | 2 | 3 |
5 | 13 | 242.52 | 18 | 15.29 | 696 | 192 | 3.28 / 18.38 | 2 | 3 |
6 | 13 | 21.72 | 18 | 15.32 | 361 | 100 | 3.38 / 18.48 | 2 | 2 |
7 | 8 | 0.00 | 165 | 15.28 | 308 | 777 | 4.16 / 19.26 | 2 | 4 |
Average= | 3.21 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.64 | 25 | 15.25 | 459 | 175 | 0.17 / 11.96 | 2 | 3 |
2 | 7 | 1522.84 | 52 | 15.20 | 2450 | 1936 | 2.11 / 13.90 | 2 | 2 |
3 | 13 | 604.80 | 18 | 15.23 | 1193 | 327 | 2.44 / 14.23 | 2 | 3 |
4 | 13 | 168.92 | 18 | 15.30 | 558 | 154 | 2.59 / 14.38 | 2 | 3 |
5 | 8 | 0.04 | 165 | 15.29 | 286 | 722 | 3.31 / 15.10 | 2 | 5 |
Average= | 3.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.24 | 24 | 15.26 | 466 | 171 | 0.17 / 8.22 | 2 | 3 |
2 | 7 | 1518.04 | 74 | 15.01 | 2420 | 2688 | 2.86 / 10.90 | 2 | 3 |
3 | 13 | 198.36 | 18 | 15.30 | 602 | 166 | 3.02 / 11.07 | 2 | 3 |
4 | 8 | 0.00 | 165 | 15.31 | 284 | 717 | 3.74 / 11.79 | 2 | 4 |
Average= | 2.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.96 | 26 | 15.28 | 464 | 184 | 0.18 / 4.49 | 3 | 3 |
2 | 3 | 949.12 | -1 | 15.61 | 0 | 0 | 0.00 / 4.49 | 3 | 3 |
3 | 7 | 1518.36 | 74 | 15.02 | 2412 | 2681 | 2.87 / 7.17 | 2 | 3 |
4 | 13 | 182.32 | 18 | 15.32 | 578 | 159 | 3.02 / 7.33 | 2 | 3 |
5 | 8 | 0.16 | 165 | 15.31 | 282 | 712 | 3.74 / 8.05 | 2 | 6 |
Average= | 2.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.28 | 23 | 15.41 | 409 | 145 | 0.14 / 1.59 | 3 | 3 |
2 | 3 | 1060.72 | 2 | 15.29 | 1898 | 58 | 0.20 / 1.64 | 2 | 2 |
3 | 7 | 999.16 | 75 | 15.17 | 1704 | 1939 | 2.14 / 3.58 | 2 | 3 |
4 | 8 | -0.04 | 165 | 15.35 | 287 | 727 | 2.87 / 4.31 | 2 | 3 |
Average= | 2.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 83.60 | 22 | 15.55 | 371 | 127 | 0.13 / 0.13 | 3 | 3 |
2 | 7 | 98.44 | 74 | 15.52 | 383 | 440 | 0.57 / 0.57 | 3 | 3 |
3 | 8 | 0.08 | 240 | 15.49 | 235 | 874 | 1.44 / 1.44 | 3 | 11 |
Average= | 1.44 (KJ/cycle) |