SIO Argo Site:
Pump Diagnostics Page   



Serial= 8831 WMO= 3902183

Return

←PreviousNext→

Cycle 188 GMT 21/12/2024 4:55:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.60 30 15.06 484 219 0.22 / 797.38 2 3
2 7 2003.48 52 15.01 3098 2418 2.64 / 799.80 2 2
3 13 1017.04 16 14.96 1787 428 3.06 / 800.23 2 3
4 13 455.84 16 15.05 1009 243 3.31 / 800.47 2 4
5 13 80.08 16 15.13 445 108 3.42 / 800.58 2 3
6 8 0.20 165 15.10 304 757 4.17 / 801.34 2 5
Average= 4.24
(KJ/cycle)

Cycle 187 GMT 11/12/2024 10:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 30 15.06 469 212 0.21 / 793.15 2 3
2 7 2003.28 53 15.02 3102 2469 2.68 / 795.62 2 3
3 13 1025.96 16 14.96 1803 432 3.11 / 796.05 2 4
4 13 465.84 16 15.05 1021 246 3.36 / 796.30 2 4
5 13 82.56 16 15.14 451 109 3.47 / 796.40 2 6
6 8 0.00 165 15.11 305 760 4.23 / 797.16 2 3
Average= 4.24
(KJ/cycle)

Cycle 186 GMT 1/12/2024 15: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.60 30 15.06 496 224 0.22 / 788.89 2 3
2 7 2003.12 53 15.01 3112 2476 2.70 / 791.36 2 3
3 13 1032.80 16 14.96 1809 433 3.13 / 791.80 2 4
4 13 477.08 16 15.05 1039 250 3.38 / 792.05 2 4
5 13 87.32 16 15.13 460 111 3.49 / 792.16 2 5
6 8 0.12 165 15.11 312 778 4.27 / 792.94 2 7
Average= 4.24
(KJ/cycle)

Cycle 185 GMT 21/11/2024 20:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 30 15.06 490 221 0.22 / 784.64 2 2
2 7 2003.52 53 15.01 3109 2473 2.69 / 787.11 2 3
3 13 1018.84 16 14.96 1798 430 3.13 / 787.54 2 3
4 13 463.68 16 15.06 1020 246 3.37 / 787.79 2 4
5 13 82.80 16 15.13 450 109 3.48 / 787.90 2 5
6 8 -0.32 165 15.11 307 765 4.25 / 788.66 2 11
Average= 4.24
(KJ/cycle)

Cycle 184 GMT 12/11/2024 1:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 30 15.05 472 213 0.21 / 780.35 2 2
2 7 2011.56 53 15.03 3142 2503 2.72 / 782.85 2 3
3 13 1022.48 16 14.97 1801 431 3.15 / 783.29 2 4
4 13 460.92 16 15.06 1013 244 3.39 / 783.53 2 4
5 13 77.52 16 15.15 447 108 3.50 / 783.64 2 3
6 8 0.32 165 15.12 313 781 4.28 / 784.42 2 6
Average= 4.24
(KJ/cycle)

Cycle 183 GMT 2/11/2024 6: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.48 30 15.07 494 223 0.22 / 775.76 2 3
2 7 2007.92 53 15.03 3125 2489 2.71 / 778.25 2 3
3 13 1028.64 16 14.97 1810 434 3.15 / 778.68 2 4
4 13 457.64 16 15.07 1006 243 3.39 / 778.92 2 4
5 13 72.76 16 15.16 434 105 3.49 / 779.03 2 3
6 8 -0.04 165 15.13 307 766 4.26 / 779.79 2 3
7 14 -0.04 75 15.09 304 344 4.60 / 780.14 4 10
Average= 4.24
(KJ/cycle)

Cycle 182 GMT 23/10/2024 11: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.84 30 15.07 500 226 0.23 / 771.55 2 2
2 7 2002.80 52 15.03 3107 2428 2.65 / 773.97 2 2
3 13 1024.48 16 14.97 1809 433 3.09 / 774.41 2 5
4 13 465.20 16 15.06 1021 246 3.33 / 774.65 2 4
5 13 74.56 16 15.15 440 107 3.44 / 774.76 2 5
6 8 0.16 165 15.13 310 774 4.21 / 775.53 2 9
Average= 4.24
(KJ/cycle)

Cycle 181 GMT 13/10/2024 16:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.84 30 15.05 501 226 0.23 / 767.25 2 3
2 7 2012.00 53 15.03 3145 2505 2.73 / 769.75 2 3
3 13 1015.16 16 14.99 1790 429 3.16 / 770.18 2 4
4 13 461.56 16 15.08 1012 244 3.40 / 770.43 2 4
5 13 78.72 16 15.15 445 108 3.51 / 770.54 2 3
6 8 0.16 165 15.13 314 784 4.30 / 771.32 2 5
Average= 4.24
(KJ/cycle)

Cycle 180 GMT 3/10/2024 21:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.20 30 15.08 508 230 0.23 / 762.64 2 2
2 7 2003.16 53 15.03 3102 2471 2.70 / 765.11 2 3
3 13 1020.76 16 14.97 1801 431 3.13 / 765.54 2 5
4 13 459.12 16 15.07 1012 244 3.38 / 765.79 2 4
5 13 73.28 16 15.15 438 106 3.48 / 765.89 2 3
6 8 -0.08 165 15.12 313 781 4.26 / 766.67 2 5
7 14 -0.08 75 15.09 309 350 4.61 / 767.02 2 11
Average= 4.24
(KJ/cycle)

Cycle 179 GMT 24/ 9/2024 2:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.28 31 15.07 498 233 0.23 / 758.40 2 3
2 7 2003.08 53 15.04 3110 2479 2.71 / 760.88 2 2
3 13 913.32 16 15.01 1652 397 3.11 / 761.28 2 4
4 13 502.76 16 15.06 1078 260 3.37 / 761.54 2 4
5 13 46.88 16 15.16 392 95 3.46 / 761.63 2 3
6 8 0.00 165 15.13 312 779 4.24 / 762.41 2 10
Average= 4.24
(KJ/cycle)

Cycle 178 GMT 14/ 9/2024 7:30:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 31 15.08 474 222 0.22 / 754.12 2 3
2 7 2007.36 53 15.03 3122 2487 2.71 / 756.60 2 3
3 13 1029.56 16 14.98 1811 434 3.14 / 757.04 2 4
4 13 471.52 16 15.07 1029 248 3.39 / 757.29 2 3
5 13 78.44 16 15.16 443 107 3.50 / 757.39 2 5
6 8 0.04 165 15.13 310 774 4.27 / 758.17 2 9
Average= 4.24
(KJ/cycle)

Cycle 177 GMT 4/ 9/2024 12:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.08 31 15.08 485 227 0.23 / 749.86 2 3
2 7 2013.44 53 15.02 3105 2472 2.70 / 752.33 2 3
3 13 1031.16 16 14.98 1812 434 3.13 / 752.77 2 4
4 13 473.92 16 15.07 1034 249 3.38 / 753.01 2 4
5 13 89.16 16 15.15 464 112 3.49 / 753.13 2 3
6 8 0.12 165 15.12 308 768 4.26 / 753.90 2 8
Average= 4.24
(KJ/cycle)

Cycle 176 GMT 25/ 8/2024 17:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 30 15.06 498 225 0.22 / 745.57 2 3
2 7 2003.12 53 15.04 3110 2479 2.70 / 748.05 2 3
3 13 1015.72 16 14.98 1790 429 3.13 / 748.48 2 4
4 13 576.60 16 15.05 1177 283 3.42 / 748.76 2 4
5 13 64.84 16 15.16 418 101 3.52 / 748.87 2 6
6 8 0.16 165 15.14 307 767 4.28 / 749.63 2 4
Average= 4.24
(KJ/cycle)

Cycle 175 GMT 15/ 8/2024 22:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.68 30 15.08 490 222 0.22 / 741.26 2 3
2 7 2010.32 53 15.03 3114 2481 2.70 / 743.74 2 3
3 13 1016.00 16 14.97 1789 429 3.13 / 744.17 2 3
4 13 576.48 16 15.02 1177 283 3.41 / 744.45 2 4
5 13 123.64 16 15.13 515 125 3.54 / 744.58 2 3
6 8 0.12 165 15.11 309 770 4.31 / 745.35 2 6
Average= 4.23
(KJ/cycle)

Cycle 174 GMT 6/ 8/2024 3:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.12 30 15.07 507 229 0.23 / 737.03 2 3
2 7 2002.64 53 15.03 3108 2476 2.71 / 739.50 2 3
3 13 1018.68 16 14.98 1786 428 3.13 / 739.93 2 4
4 13 456.44 16 15.07 1005 242 3.38 / 740.17 2 4
5 13 79.24 16 15.15 439 106 3.48 / 740.28 2 4
6 8 0.00 165 15.13 304 759 4.24 / 741.04 2 5
Average= 4.23
(KJ/cycle)

Cycle 173 GMT 27/ 7/2024 8:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.76 30 15.07 491 222 0.22 / 732.81 2 3
2 7 2010.00 52 15.02 3119 2436 2.66 / 735.24 2 3
3 13 1020.20 16 14.96 1801 431 3.09 / 735.67 2 4
4 13 468.76 16 15.06 1027 247 3.34 / 735.92 2 4
5 13 82.24 16 15.15 455 110 3.45 / 736.03 2 4
6 8 0.04 165 15.12 308 768 4.22 / 736.80 2 4
Average= 4.23
(KJ/cycle)

Cycle 172 GMT 17/ 7/2024 14: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 30 15.08 472 214 0.21 / 728.54 2 3
2 7 2011.88 53 15.02 3122 2485 2.70 / 731.03 2 3
3 13 1026.88 16 14.97 1806 433 3.13 / 731.46 2 3
4 13 467.80 16 15.06 1024 247 3.38 / 731.71 2 4
5 13 80.68 16 15.14 446 108 3.49 / 731.82 2 6
6 8 -0.08 165 15.12 307 766 4.25 / 732.58 2 9
Average= 4.23
(KJ/cycle)

Cycle 171 GMT 7/ 7/2024 18:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.76 30 15.09 491 222 0.22 / 724.31 2 3
2 7 2010.52 53 15.03 3110 2477 2.70 / 726.78 2 2
3 13 1025.64 16 14.97 1800 431 3.13 / 727.21 2 4
4 13 466.52 16 15.07 1026 247 3.38 / 727.46 2 4
5 13 87.68 16 15.15 455 110 3.49 / 727.57 2 4
6 8 0.12 165 15.13 304 759 4.25 / 728.33 2 11
Average= 4.23
(KJ/cycle)

Cycle 170 GMT 27/ 6/2024 23:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.68 30 15.09 493 223 0.22 / 720.10 2 3
2 7 2003.60 52 15.04 3116 2437 2.66 / 722.54 2 3
3 13 1023.40 16 14.99 1801 432 3.09 / 722.97 2 4
4 13 461.40 16 15.07 1013 244 3.34 / 723.21 2 3
5 13 82.08 16 15.15 446 108 3.44 / 723.32 2 6
6 8 0.24 165 15.14 305 762 4.21 / 724.08 2 11
Average= 4.23
(KJ/cycle)

Cycle 169 GMT 18/ 6/2024 4:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.60 30 15.08 497 225 0.22 / 715.83 2 3
2 7 2002.56 53 15.04 3103 2473 2.70 / 718.30 2 3
3 13 1016.40 16 14.98 1797 431 3.13 / 718.73 2 3
4 13 575.36 16 15.05 1183 285 3.41 / 719.02 2 4
5 13 68.24 16 15.16 421 102 3.52 / 719.12 2 3
6 8 0.20 165 15.13 304 759 4.27 / 719.88 2 14
Average= 4.23
(KJ/cycle)

Cycle 168 GMT 8/ 6/2024 10: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.04 30 15.08 484 219 0.22 / 711.56 2 3
2 7 2012.56 53 15.03 3121 2486 2.71 / 714.05 2 3
3 13 1025.76 16 14.98 1808 433 3.14 / 714.48 2 3
4 13 463.20 16 15.08 1019 246 3.38 / 714.73 2 4
5 13 91.28 16 15.15 461 112 3.50 / 714.84 2 8
6 8 0.00 165 15.14 305 762 4.26 / 715.60 2 10
Average= 4.23
(KJ/cycle)

Cycle 167 GMT 29/ 5/2024 15:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 30 15.09 460 208 0.21 / 707.30 2 3
2 7 2011.24 53 15.03 3127 2491 2.70 / 709.80 2 3
3 13 1025.04 16 14.98 1812 434 3.13 / 710.23 2 4
4 13 457.28 16 15.07 1012 244 3.38 / 710.47 2 3
5 13 84.52 16 15.16 450 109 3.49 / 710.58 2 7
6 8 0.04 165 15.13 305 761 4.25 / 711.34 2 10
Average= 4.23
(KJ/cycle)

Cycle 166 GMT 19/ 5/2024 19:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 30 15.09 484 219 0.22 / 703.05 2 3
2 7 2011.44 53 15.03 3131 2494 2.71 / 705.54 2 3
3 13 1028.24 16 14.98 1811 434 3.15 / 705.97 2 5
4 13 466.72 16 15.08 1027 248 3.40 / 706.22 2 4
5 13 82.28 16 15.16 453 110 3.50 / 706.33 2 5
6 8 0.12 165 15.14 306 764 4.27 / 707.10 2 9
Average= 4.23
(KJ/cycle)

Cycle 165 GMT 10/ 5/2024 0:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 30 15.06 481 217 0.22 / 698.80 2 3
2 7 2009.20 53 15.04 3114 2482 2.70 / 701.28 2 3
3 13 1015.92 16 14.98 1796 430 3.13 / 701.71 2 4
4 13 456.44 16 15.08 1009 243 3.37 / 701.96 2 4
5 13 80.16 16 15.16 452 110 3.48 / 702.07 2 5
6 8 0.00 165 15.13 305 761 4.24 / 702.83 2 12
Average= 4.23
(KJ/cycle)

Cycle 164 GMT 30/ 4/2024 5:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 30 15.08 462 209 0.21 / 694.25 2 3
2 7 2003.88 52 15.02 3113 2431 2.64 / 696.68 2 3
3 13 1028.92 16 14.96 1806 432 3.07 / 697.12 2 3
4 13 466.76 16 15.07 1022 246 3.32 / 697.36 2 4
5 13 89.68 16 15.14 458 111 3.43 / 697.47 2 3
6 8 0.16 165 15.12 307 766 4.20 / 698.24 2 4
7 14 0.16 75 15.09 303 343 4.54 / 698.58 2 13
Average= 4.23
(KJ/cycle)

Cycle 163 GMT 20/ 4/2024 10:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 30 15.08 459 208 0.21 / 690.00 2 3
2 7 2010.96 53 15.04 3127 2493 2.70 / 692.50 2 3
3 13 1020.52 16 14.98 1803 432 3.13 / 692.93 2 4
4 13 460.08 16 15.08 1017 245 3.38 / 693.17 2 4
5 13 85.68 16 15.16 454 110 3.49 / 693.28 2 3
6 8 0.04 165 15.13 304 759 4.25 / 694.04 2 11
Average= 4.23
(KJ/cycle)

Cycle 162 GMT 10/ 4/2024 15:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.00 30 15.09 481 218 0.22 / 685.78 2 3
2 7 2011.72 53 15.05 3118 2487 2.70 / 688.27 2 2
3 13 910.52 16 15.00 1659 398 3.10 / 688.67 2 4
4 13 502.04 16 15.08 1070 258 3.36 / 688.93 2 3
5 13 101.96 16 15.15 477 116 3.48 / 689.04 2 3
6 8 0.20 165 15.14 302 754 4.23 / 689.80 2 9
Average= 4.23
(KJ/cycle)

Cycle 161 GMT 31/ 3/2024 20:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.20 30 15.08 482 218 0.22 / 681.53 2 3
2 7 2011.44 53 15.04 3124 2490 2.71 / 684.02 2 3
3 13 1025.00 16 15.00 1807 434 3.14 / 684.45 2 4
4 13 453.92 16 15.09 1010 244 3.39 / 684.69 2 4
5 13 80.12 16 15.16 446 108 3.49 / 684.80 2 3
6 8 0.32 165 15.15 305 762 4.26 / 685.57 2 11
Average= 4.23
(KJ/cycle)

Cycle 160 GMT 22/ 3/2024 1:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 30 15.07 457 207 0.21 / 677.24 2 3
2 7 2004.28 53 15.04 3122 2489 2.70 / 679.73 2 3
3 13 1020.48 16 14.99 1794 430 3.13 / 680.16 2 4
4 13 578.36 16 15.05 1186 286 3.41 / 680.45 2 4
5 13 71.80 16 15.17 427 104 3.51 / 680.55 2 3
6 8 -0.04 165 15.14 303 757 4.27 / 681.31 2 8
Average= 4.23
(KJ/cycle)

Cycle 159 GMT 12/ 3/2024 6:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.08 30 15.08 492 223 0.22 / 673.02 2 3
2 7 2010.20 53 15.03 3116 2482 2.70 / 675.50 2 3
3 13 1021.96 16 14.97 1799 431 3.14 / 675.93 2 4
4 13 451.00 16 15.07 1000 241 3.38 / 676.17 2 4
5 13 81.40 16 15.15 443 107 3.48 / 676.28 2 3
6 8 0.04 165 15.13 304 759 4.24 / 677.04 2 7
Average= 4.23
(KJ/cycle)

Cycle 158 GMT 2/ 3/2024 11:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.44 30 15.09 481 218 0.22 / 668.76 2 3
2 7 2005.20 53 15.04 3112 2481 2.70 / 671.24 2 3
3 13 1021.24 16 14.99 1801 432 3.13 / 671.67 2 3
4 13 458.32 16 15.08 1008 243 3.37 / 671.92 2 4
5 13 86.44 16 15.16 454 110 3.48 / 672.03 2 3
6 8 0.20 165 15.13 308 769 4.25 / 672.79 2 6
Average= 4.23
(KJ/cycle)

Cycle 157 GMT 21/ 2/2024 16:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 30 15.09 457 207 0.21 / 664.55 2 3
2 7 2011.00 52 15.03 3117 2436 2.64 / 666.98 2 2
3 13 1028.44 16 14.97 1807 433 3.08 / 667.42 2 3
4 13 466.20 16 15.08 1019 246 3.32 / 667.66 2 4
5 13 86.52 16 15.15 461 112 3.43 / 667.78 2 3
6 8 0.20 165 15.13 307 766 4.20 / 668.54 2 3
Average= 4.23
(KJ/cycle)

Cycle 156 GMT 11/ 2/2024 21: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 30 15.09 448 203 0.20 / 660.31 2 3
2 7 2013.28 53 15.03 3117 2483 2.69 / 662.80 2 3
3 13 1012.60 16 14.99 1785 428 3.11 / 663.23 2 4
4 13 454.96 16 15.08 1003 242 3.36 / 663.47 2 4
5 13 81.32 16 15.15 445 108 3.46 / 663.58 2 3
6 8 0.16 165 15.14 307 767 4.23 / 664.34 2 6
Average= 4.23
(KJ/cycle)

Cycle 155 GMT 2/ 2/2024 1:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 30 15.08 458 207 0.21 / 656.08 2 3
2 7 2012.40 53 15.03 3112 2479 2.69 / 658.56 2 2
3 13 1028.04 16 14.98 1801 432 3.12 / 658.99 2 4
4 13 465.72 16 15.08 1026 248 3.37 / 659.24 2 4
5 13 83.00 16 15.16 452 110 3.48 / 659.35 2 3
6 8 -0.04 165 15.14 304 759 4.23 / 660.11 2 4
Average= 4.23
(KJ/cycle)

Cycle 154 GMT 23/ 1/2024 4:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.92 30 15.09 483 219 0.22 / 651.85 2 3
2 7 2004.32 53 15.03 3110 2477 2.70 / 654.33 2 3
3 13 1015.84 16 14.98 1794 430 3.13 / 654.76 2 3
4 13 453.00 16 15.08 1000 241 3.37 / 655.00 2 4
5 13 82.56 16 15.16 446 108 3.48 / 655.11 2 4
6 8 0.04 165 15.13 308 769 4.24 / 655.88 2 13
Average= 4.23
(KJ/cycle)

Cycle 153 GMT 13/ 1/2024 6:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.76 30 15.10 481 218 0.22 / 647.59 2 3
2 7 2009.48 53 15.05 3115 2485 2.70 / 650.08 2 3
3 13 1027.88 16 14.99 1808 434 3.14 / 650.51 2 4
4 13 466.00 16 15.08 1020 246 3.38 / 650.76 2 4
5 13 84.24 16 15.17 452 110 3.49 / 650.86 2 4
6 8 0.16 165 15.15 307 767 4.26 / 651.63 2 10
Average= 4.23
(KJ/cycle)

Cycle 152 GMT 3/ 1/2024 9: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.44 30 15.09 491 222 0.22 / 643.35 2 3
2 7 2003.24 53 15.04 3113 2481 2.70 / 645.83 2 3
3 13 1011.52 16 15.00 1779 427 3.13 / 646.26 2 3
4 13 453.60 16 15.10 1003 242 3.37 / 646.50 2 4
5 13 74.60 16 15.18 432 105 3.48 / 646.61 2 4
6 8 0.12 165 15.15 307 767 4.25 / 647.37 2 5
Average= 4.23
(KJ/cycle)

Cycle 151 GMT 24/12/2023 11:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.36 30 15.10 483 219 0.22 / 639.04 2 3
2 7 2002.64 53 15.04 3106 2476 2.69 / 641.52 2 3
3 13 1024.64 16 14.99 1801 432 3.13 / 641.95 2 4
4 13 580.40 16 15.06 1191 287 3.41 / 642.24 2 4
5 13 126.20 16 15.16 516 125 3.54 / 642.36 2 5
6 8 0.20 165 15.15 306 765 4.30 / 643.13 2 7
Average= 4.23
(KJ/cycle)

Cycle 150 GMT 14/12/2023 14:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.72 30 15.09 495 224 0.22 / 634.82 2 3
2 7 2002.84 53 15.05 3111 2481 2.71 / 637.30 2 3
3 13 914.48 16 15.02 1647 396 3.10 / 637.70 2 4
4 13 502.52 16 15.09 1067 258 3.36 / 637.95 2 3
5 13 97.80 16 15.17 467 113 3.47 / 638.07 2 5
6 8 -0.04 165 15.14 303 757 4.23 / 638.82 2 10
Average= 4.23
(KJ/cycle)

Cycle 149 GMT 4/12/2023 16:39:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.84 30 15.10 488 221 0.22 / 630.56 2 2
2 7 2012.04 52 15.05 3123 2444 2.67 / 633.01 2 3
3 13 1022.84 16 15.00 1798 432 3.10 / 633.44 2 3
4 13 588.56 16 15.06 1194 288 3.38 / 633.73 2 4
5 13 71.92 16 15.17 428 104 3.49 / 633.83 2 5
6 8 0.08 165 15.15 306 765 4.25 / 634.59 2 9
Average= 4.23
(KJ/cycle)

Cycle 148 GMT 24/11/2023 19: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.84 30 15.10 490 222 0.22 / 626.31 2 3
2 7 2003.36 52 15.05 3108 2432 2.65 / 628.74 2 2
3 13 1012.32 16 15.00 1782 428 3.08 / 629.17 2 3
4 13 574.12 16 15.07 1174 283 3.37 / 629.45 2 3
5 13 125.88 16 15.17 518 126 3.49 / 629.58 2 3
6 8 0.20 165 15.15 306 765 4.26 / 630.34 2 9
Average= 4.23
(KJ/cycle)

Cycle 147 GMT 14/11/2023 21:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.32 30 15.09 494 224 0.22 / 622.03 2 3
2 7 2010.72 53 15.04 3139 2502 2.73 / 624.53 2 3
3 13 1026.72 16 15.01 1805 433 3.16 / 624.96 2 3
4 13 467.24 16 15.10 1020 246 3.41 / 625.21 2 4
5 13 85.12 16 15.18 454 110 3.52 / 625.32 2 4
6 8 0.16 165 15.15 307 767 4.28 / 626.09 2 9
Average= 4.23
(KJ/cycle)

Cycle 146 GMT 5/11/2023 0: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.36 30 15.10 492 223 0.22 / 617.82 2 3
2 7 2009.44 52 15.04 3115 2436 2.66 / 620.26 2 3
3 13 1012.24 16 14.99 1782 427 3.09 / 620.69 2 3
4 13 448.04 16 15.08 996 240 3.33 / 620.93 2 4
5 13 77.80 16 15.18 437 106 3.43 / 621.04 2 6
6 8 0.08 165 15.15 307 767 4.20 / 621.80 2 8
Average= 4.23
(KJ/cycle)

Cycle 145 GMT 26/10/2023 2:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.48 30 15.09 493 223 0.22 / 613.58 2 3
2 7 2009.72 53 15.05 3113 2483 2.71 / 616.07 2 2
3 13 1017.48 16 15.00 1796 431 3.14 / 616.50 2 4
4 13 445.24 16 15.10 993 240 3.38 / 616.74 2 3
5 13 78.04 16 15.18 440 107 3.48 / 616.84 2 3
6 8 0.12 165 15.16 303 758 4.24 / 617.60 2 5
Average= 4.23
(KJ/cycle)

Cycle 144 GMT 16/10/2023 4:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 30 15.11 491 223 0.22 / 608.99 2 3
2 7 2003.72 52 15.04 3102 2426 2.65 / 611.41 2 3
3 13 1031.56 16 15.00 1811 435 3.08 / 611.85 2 3
4 13 581.20 16 15.07 1189 287 3.37 / 612.14 2 4
5 13 123.16 16 15.16 510 124 3.49 / 612.26 2 3
6 8 0.28 165 15.15 304 760 4.25 / 613.02 2 5
7 14 0.28 75 15.12 300 340 4.59 / 613.36 3 14
Average= 4.23
(KJ/cycle)

Cycle 143 GMT 6/10/2023 7:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.24 30 15.13 496 225 0.23 / 604.68 2 3
2 7 2008.44 53 15.06 3115 2486 2.71 / 607.17 2 3
3 13 1013.08 16 15.01 1789 430 3.14 / 607.60 2 4
4 13 570.80 16 15.08 1177 284 3.43 / 607.88 2 4
5 13 118.28 16 15.18 504 122 3.55 / 608.00 2 4
6 8 0.04 165 15.16 305 763 4.31 / 608.77 2 3
Average= 4.23
(KJ/cycle)

Cycle 142 GMT 26/ 9/2023 10: 2:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.04 30 15.10 489 222 0.22 / 600.42 2 2
2 7 2003.36 53 15.07 3110 2484 2.71 / 602.91 2 3
3 13 1019.24 16 15.02 1802 433 3.14 / 603.34 2 5
4 13 457.00 16 15.10 1015 245 3.38 / 603.58 2 3
5 13 81.20 16 15.19 446 108 3.49 / 603.69 2 5
6 8 0.32 165 15.17 305 763 4.26 / 604.46 2 11
Average= 4.23
(KJ/cycle)

Cycle 141 GMT 16/ 9/2023 12:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 30 15.10 467 212 0.21 / 595.82 2 3
2 7 2007.76 53 15.05 3116 2485 2.70 / 598.30 2 3
3 13 1025.40 16 15.01 1804 433 3.13 / 598.74 2 3
4 13 458.32 16 15.10 1016 245 3.38 / 598.98 2 3
5 13 84.64 16 15.18 449 109 3.48 / 599.09 2 7
6 8 0.36 165 15.16 307 768 4.25 / 599.86 2 3
7 14 0.36 75 15.13 300 340 4.59 / 600.20 2 14
Average= 4.23
(KJ/cycle)

Cycle 140 GMT 6/ 9/2023 14:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.56 30 15.09 483 219 0.22 / 591.24 2 2
2 7 2004.64 53 15.06 3120 2490 2.71 / 593.73 2 3
3 13 1002.76 16 15.02 1775 427 3.14 / 594.16 2 4
4 13 439.12 16 15.12 985 238 3.37 / 594.40 2 4
5 13 81.24 16 15.19 444 108 3.48 / 594.51 2 4
6 8 0.12 165 15.17 303 758 4.24 / 595.27 2 7
7 14 0.12 75 15.14 301 342 4.58 / 595.61 2 13
Average= 4.22
(KJ/cycle)

Cycle 139 GMT 27/ 8/2023 17:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.20 30 15.12 494 224 0.22 / 586.69 2 3
2 7 2003.32 53 15.05 3107 2478 2.70 / 589.17 2 3
3 13 900.04 16 15.03 1635 393 3.10 / 589.56 2 4
4 13 476.52 16 15.10 1039 251 3.35 / 589.81 2 4
5 13 84.16 16 15.18 450 109 3.46 / 589.92 2 5
6 8 -0.08 165 15.16 305 763 4.22 / 590.68 2 5
7 14 -0.08 75 15.13 300 340 4.56 / 591.03 3 21
Average= 4.22
(KJ/cycle)

Cycle 138 GMT 17/ 8/2023 19:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.52 30 15.10 492 223 0.22 / 582.41 2 3
2 7 2012.12 53 15.05 3139 2504 2.73 / 584.92 2 3
3 13 1023.92 16 15.01 1806 434 3.16 / 585.35 2 4
4 13 456.08 16 15.11 1014 245 3.41 / 585.60 2 4
5 13 82.52 16 15.19 446 108 3.51 / 585.71 2 3
6 8 0.12 165 15.17 304 761 4.27 / 586.47 2 11
Average= 4.22
(KJ/cycle)

Cycle 137 GMT 7/ 8/2023 21:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.60 30 15.11 493 223 0.22 / 578.16 2 3
2 7 2004.08 53 15.05 3109 2480 2.70 / 580.64 2 3
3 13 1025.84 16 15.00 1807 434 3.14 / 581.07 2 4
4 13 465.48 16 15.10 1027 248 3.39 / 581.32 2 4
5 13 85.80 16 15.18 452 110 3.49 / 581.43 2 4
6 8 0.08 165 15.16 305 763 4.26 / 582.19 2 7
Average= 4.22
(KJ/cycle)

Cycle 136 GMT 29/ 7/2023 0:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.68 29 15.11 485 213 0.21 / 573.95 2 3
2 7 2010.72 52 15.04 3116 2437 2.65 / 576.39 2 3
3 13 1012.84 16 15.01 1788 429 3.08 / 576.82 2 4
4 13 451.16 16 15.10 1001 242 3.32 / 577.06 2 3
5 13 83.88 16 15.19 451 110 3.43 / 577.17 2 3
6 8 0.04 165 15.16 305 763 4.19 / 577.93 2 5
Average= 4.22
(KJ/cycle)

Cycle 135 GMT 19/ 7/2023 2:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.72 29 15.11 490 215 0.21 / 569.72 2 3
2 7 2004.96 53 15.05 3111 2481 2.70 / 572.20 2 3
3 13 1013.80 16 15.02 1792 431 3.13 / 572.63 2 4
4 13 454.44 16 15.11 1003 242 3.37 / 572.87 2 4
5 13 81.72 16 15.19 446 108 3.48 / 572.98 2 3
6 8 0.00 165 15.17 303 758 4.24 / 573.74 2 5
Average= 4.22
(KJ/cycle)

Cycle 134 GMT 9/ 7/2023 5: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.68 29 15.11 486 213 0.21 / 565.48 2 3
2 7 2013.44 53 15.05 3138 2503 2.72 / 567.98 2 3
3 13 899.00 16 15.03 1632 392 3.11 / 568.37 2 4
4 13 491.08 16 15.09 1054 254 3.36 / 568.63 2 4
5 13 96.44 16 15.18 476 116 3.48 / 568.74 2 3
6 8 0.20 165 15.16 304 760 4.24 / 569.50 2 9
Average= 4.22
(KJ/cycle)

Cycle 133 GMT 29/ 6/2023 7:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 29 15.12 466 204 0.20 / 561.22 2 3
2 7 2010.36 53 15.06 3123 2493 2.70 / 563.71 2 2
3 13 1016.96 16 15.01 1795 431 3.13 / 564.15 2 4
4 13 459.72 16 15.11 1012 245 3.37 / 564.39 2 4
5 13 83.64 16 15.18 450 109 3.48 / 564.50 2 3
6 8 0.08 165 15.16 306 765 4.25 / 565.26 2 4
Average= 4.22
(KJ/cycle)

Cycle 132 GMT 19/ 6/2023 9:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 29 15.12 459 201 0.20 / 557.00 2 3
2 7 2003.92 53 15.06 3115 2486 2.69 / 559.48 2 3
3 13 911.08 16 15.04 1654 398 3.09 / 559.88 2 3
4 13 488.52 16 15.11 1055 255 3.34 / 560.13 2 4
5 13 95.36 16 15.19 469 114 3.45 / 560.25 2 3
6 8 0.00 165 15.17 307 768 4.22 / 561.02 2 4
Average= 4.22
(KJ/cycle)

Cycle 131 GMT 9/ 6/2023 12:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 29 15.11 482 211 0.21 / 552.77 2 3
2 7 2011.36 53 15.05 3114 2484 2.70 / 555.26 2 3
3 13 1006.60 16 15.03 1780 428 3.12 / 555.68 2 4
4 13 452.96 16 15.11 1000 242 3.36 / 555.92 2 3
5 13 81.68 16 15.19 448 109 3.47 / 556.03 2 4
6 8 0.08 165 15.16 304 760 4.23 / 556.79 2 16
Average= 4.22
(KJ/cycle)

Cycle 130 GMT 30/ 5/2023 14:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 29 15.11 479 210 0.21 / 548.17 2 3
2 7 2006.60 53 15.06 3118 2489 2.70 / 550.66 2 3
3 13 1020.60 16 15.03 1806 434 3.13 / 551.09 2 3
4 13 454.24 16 15.12 1006 243 3.38 / 551.33 2 3
5 13 84.96 16 15.20 453 110 3.49 / 551.44 2 3
6 8 0.16 165 15.17 308 771 4.26 / 552.22 2 14
7 14 0.16 75 15.14 303 344 4.60 / 552.56 2 14
Average= 4.22
(KJ/cycle)

Cycle 129 GMT 20/ 5/2023 17: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 29 15.12 461 202 0.20 / 543.61 2 3
2 7 2002.84 53 15.07 3109 2483 2.69 / 546.10 2 3
3 13 896.04 16 15.04 1627 392 3.08 / 546.49 2 4
4 13 478.24 16 15.11 1042 252 3.33 / 546.74 2 3
5 13 85.52 16 15.20 454 110 3.44 / 546.85 2 6
6 8 -0.12 165 15.17 305 763 4.20 / 547.61 2 7
7 14 -0.12 75 15.13 303 344 4.55 / 547.96 3 8
Average= 4.22
(KJ/cycle)

Cycle 128 GMT 10/ 5/2023 19:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.40 29 15.12 487 214 0.21 / 539.37 2 3
2 7 2012.16 53 15.06 3125 2494 2.71 / 541.86 2 3
3 13 1014.72 16 15.03 1797 432 3.14 / 542.30 2 4
4 13 448.60 16 15.12 1000 242 3.38 / 542.54 2 4
5 13 78.88 16 15.20 444 108 3.49 / 542.65 2 3
6 8 -0.08 165 15.17 306 766 4.26 / 543.41 2 13
Average= 4.21
(KJ/cycle)

Cycle 127 GMT 30/ 4/2023 21:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 29 15.13 459 201 0.20 / 535.11 2 3
2 7 2011.36 53 15.07 3129 2499 2.70 / 537.61 2 2
3 13 1007.88 16 15.03 1781 428 3.13 / 538.04 2 4
4 13 437.20 16 15.12 981 237 3.37 / 538.28 2 4
5 13 73.32 16 15.21 436 106 3.47 / 538.38 2 5
6 8 0.16 165 15.18 309 774 4.25 / 539.16 2 5
Average= 4.21
(KJ/cycle)

Cycle 126 GMT 20/ 4/2023 23:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.52 29 15.13 484 212 0.21 / 530.88 2 3
2 7 2011.80 53 15.05 3111 2481 2.69 / 533.37 2 2
3 13 1012.92 16 15.01 1783 428 3.12 / 533.79 2 4
4 13 455.56 16 15.12 1008 244 3.37 / 534.04 2 3
5 13 75.36 16 15.20 437 106 3.47 / 534.14 2 4
6 8 0.12 165 15.17 306 766 4.24 / 534.91 2 8
Average= 4.21
(KJ/cycle)

Cycle 125 GMT 11/ 4/2023 2:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 29 15.13 457 201 0.20 / 526.64 2 3
2 7 2010.68 53 15.06 3115 2486 2.69 / 529.13 2 3
3 13 1022.36 16 15.02 1796 432 3.12 / 529.56 2 4
4 13 449.92 16 15.12 998 241 3.36 / 529.80 2 4
5 13 68.60 16 15.20 423 103 3.46 / 529.91 2 3
6 8 0.00 165 15.17 306 766 4.23 / 530.67 2 8
Average= 4.21
(KJ/cycle)

Cycle 124 GMT 1/ 4/2023 4:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.64 29 15.13 487 214 0.21 / 522.46 2 3
2 7 2012.00 52 15.06 3126 2448 2.66 / 524.90 2 3
3 13 1011.60 16 15.03 1787 430 3.09 / 525.33 2 3
4 13 459.80 16 15.13 1012 245 3.34 / 525.58 2 4
5 13 75.20 16 15.21 435 106 3.44 / 525.68 2 3
6 8 0.12 165 15.17 303 758 4.20 / 526.44 2 3
Average= 4.21
(KJ/cycle)

Cycle 123 GMT 22/ 3/2023 7:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.68 29 15.12 481 211 0.21 / 518.28 2 3
2 7 2008.68 52 15.06 3117 2441 2.65 / 520.72 2 3
3 13 1008.32 16 15.03 1778 428 3.08 / 521.15 2 3
4 13 435.44 16 15.12 980 237 3.32 / 521.39 2 4
5 13 32.76 16 15.21 366 89 3.41 / 521.48 2 3
6 8 0.12 165 15.18 305 764 4.17 / 522.24 2 4
Average= 4.21
(KJ/cycle)

Cycle 122 GMT 12/ 3/2023 9:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.88 29 15.13 485 213 0.21 / 514.05 2 3
2 7 2007.88 53 15.07 3117 2490 2.70 / 516.54 2 3
3 13 1012.80 16 15.03 1787 430 3.13 / 516.97 2 4
4 13 451.68 16 15.12 997 241 3.37 / 517.21 2 4
5 13 38.76 16 15.22 376 92 3.46 / 517.30 2 4
6 8 -0.12 165 15.18 307 769 4.23 / 518.07 2 6
Average= 4.21
(KJ/cycle)

Cycle 121 GMT 2/ 3/2023 12: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 29 15.12 481 211 0.21 / 509.85 2 3
2 7 2008.44 53 15.08 3113 2488 2.70 / 512.34 2 3
3 13 905.08 16 15.04 1637 394 3.09 / 512.73 2 3
4 13 482.24 16 15.12 1044 253 3.35 / 512.98 2 4
5 13 42.08 16 15.22 380 93 3.44 / 513.07 2 4
6 8 0.04 165 15.19 305 764 4.20 / 513.84 2 5
Average= 4.21
(KJ/cycle)

Cycle 120 GMT 20/ 2/2023 14:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.64 29 15.14 487 214 0.21 / 505.25 2 3
2 7 2006.92 53 15.07 3119 2491 2.70 / 507.74 2 3
3 13 1011.20 16 15.03 1784 429 3.13 / 508.17 2 3
4 13 432.44 16 15.14 974 236 3.37 / 508.41 2 4
5 13 61.16 16 15.22 421 103 3.47 / 508.51 2 3
6 8 0.36 165 15.19 311 779 4.25 / 509.29 2 5
7 14 0.36 75 15.15 307 349 4.60 / 509.64 3 8
Average= 4.21
(KJ/cycle)

Cycle 119 GMT 10/ 2/2023 16:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.72 29 15.12 481 211 0.21 / 501.05 2 3
2 7 2011.72 52 15.08 3120 2447 2.66 / 503.50 2 3
3 13 1013.52 16 15.04 1790 431 3.09 / 503.93 2 4
4 13 436.60 16 15.14 982 238 3.33 / 504.17 2 3
5 13 66.44 16 15.21 426 104 3.43 / 504.27 2 4
6 8 0.28 165 15.19 306 767 4.20 / 505.04 2 17
Average= 4.21
(KJ/cycle)

Cycle 118 GMT 31/ 1/2023 19: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.16 29 15.15 485 213 0.21 / 496.51 2 3
2 7 2010.76 53 15.07 3121 2493 2.71 / 499.00 2 2
3 13 897.52 16 15.06 1631 393 3.10 / 499.39 2 3
4 13 470.20 16 15.13 1029 249 3.35 / 499.64 2 4
5 13 40.92 16 15.23 378 92 3.44 / 499.73 2 4
6 8 0.04 165 15.19 305 764 4.20 / 500.50 2 5
7 14 0.04 75 15.15 299 340 4.54 / 500.84 3 5
Average= 4.21
(KJ/cycle)

Cycle 117 GMT 21/ 1/2023 21:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 29 15.13 480 211 0.21 / 492.27 2 3
2 7 2007.60 53 15.08 3118 2492 2.70 / 494.76 2 3
3 13 1019.68 16 15.04 1801 433 3.14 / 495.19 2 5
4 13 443.84 16 15.15 991 240 3.38 / 495.43 2 3
5 13 66.60 16 15.22 426 104 3.48 / 495.53 2 7
6 8 -0.08 165 15.20 303 760 4.24 / 496.29 2 10
Average= 4.21
(KJ/cycle)

Cycle 116 GMT 11/ 1/2023 23:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 29 15.16 477 210 0.21 / 487.67 2 3
2 7 2005.48 53 15.08 3117 2491 2.70 / 490.16 2 3
3 13 1013.48 16 15.05 1795 432 3.13 / 490.59 2 3
4 13 438.44 16 15.15 984 239 3.37 / 490.83 2 4
5 13 62.40 16 15.23 415 101 3.47 / 490.93 2 4
6 8 0.16 165 15.21 308 773 4.25 / 491.71 2 10
7 14 0.16 75 15.17 306 348 4.59 / 492.05 3 6
Average= 4.21
(KJ/cycle)

Cycle 115 GMT 2/ 1/2023 1:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.96 29 15.13 477 209 0.21 / 483.42 2 3
2 7 2011.56 53 15.09 3134 2506 2.72 / 485.93 2 2
3 13 1010.80 16 15.05 1787 430 3.15 / 486.36 2 4
4 13 432.92 16 15.15 973 236 3.38 / 486.59 2 4
5 13 60.88 16 15.23 410 100 3.48 / 486.69 2 4
6 8 0.12 165 15.20 306 767 4.25 / 487.46 2 8
Average= 4.20
(KJ/cycle)

Cycle 114 GMT 23/12/2022 4:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.16 29 15.15 493 217 0.22 / 478.83 2 3
2 7 2011.16 53 15.07 3132 2502 2.72 / 481.34 2 3
3 13 1005.36 16 15.04 1777 428 3.15 / 481.76 2 4
4 13 441.92 16 15.14 985 239 3.38 / 482.00 2 4
5 13 63.76 16 15.22 416 101 3.49 / 482.10 2 4
6 8 0.08 165 15.19 306 767 4.25 / 482.87 2 8
7 14 0.08 75 15.15 300 341 4.59 / 483.21 4 12
Average= 4.20
(KJ/cycle)

Cycle 113 GMT 13/12/2022 6:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.68 29 15.14 490 215 0.22 / 474.62 2 3
2 7 2009.32 53 15.08 3122 2495 2.71 / 477.11 2 2
3 13 896.08 16 15.08 1624 392 3.10 / 477.51 2 3
4 13 473.52 16 15.15 1030 250 3.35 / 477.76 2 4
5 13 40.52 16 15.23 378 92 3.44 / 477.85 2 4
6 8 0.00 165 15.20 307 770 4.21 / 478.62 2 5
Average= 4.20
(KJ/cycle)

Cycle 112 GMT 3/12/2022 9: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.52 29 15.15 485 213 0.21 / 470.41 2 3
2 7 2006.80 52 15.07 3138 2459 2.67 / 472.87 2 3
3 13 1002.36 16 15.04 1777 428 3.10 / 473.30 2 3
4 13 431.24 16 15.14 976 236 3.34 / 473.54 2 3
5 13 62.32 16 15.22 419 102 3.44 / 473.64 2 4
6 8 0.04 165 15.19 306 767 4.21 / 474.40 2 4
Average= 4.20
(KJ/cycle)

Cycle 111 GMT 23/11/2022 11:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.76 29 15.15 497 218 0.22 / 466.16 2 3
2 7 2004.88 53 15.09 3137 2509 2.73 / 468.67 2 3
3 13 1001.28 16 15.05 1773 427 3.15 / 469.09 2 4
4 13 433.08 16 15.15 977 237 3.39 / 469.33 2 4
5 13 62.96 16 15.23 416 101 3.49 / 469.43 2 4
6 8 0.20 165 15.20 306 767 4.26 / 470.20 2 10
Average= 4.20
(KJ/cycle)

Cycle 110 GMT 13/11/2022 13:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.88 29 15.15 489 215 0.21 / 461.96 2 3
2 7 2004.00 52 15.07 3118 2443 2.66 / 464.40 2 3
3 13 1001.20 16 15.05 1774 427 3.09 / 464.83 2 4
4 13 431.68 16 15.16 980 238 3.32 / 465.06 2 3
5 13 63.12 16 15.22 419 102 3.43 / 465.17 2 6
6 8 0.12 165 15.20 308 772 4.20 / 465.94 2 14
Average= 4.20
(KJ/cycle)

Cycle 109 GMT 3/11/2022 16: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.48 29 15.14 491 216 0.22 / 457.70 2 3
2 7 2007.80 53 15.08 3122 2495 2.71 / 460.19 2 3
3 13 1017.60 16 15.04 1797 432 3.14 / 460.62 2 4
4 13 454.20 16 15.13 1003 243 3.39 / 460.87 2 4
5 13 72.76 16 15.21 432 105 3.49 / 460.97 2 3
6 8 0.12 165 15.19 307 769 4.26 / 461.74 2 4
Average= 4.20
(KJ/cycle)

Cycle 108 GMT 24/10/2022 18:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 29 15.14 478 210 0.21 / 453.37 2 3
2 7 2004.96 54 15.07 3119 2538 2.75 / 455.91 2 2
3 13 1004.68 16 15.04 1780 428 3.18 / 456.34 2 4
4 13 555.92 16 15.11 1152 279 3.45 / 456.62 2 3
5 13 56.48 16 15.22 405 99 3.55 / 456.71 2 2
6 8 0.00 165 15.19 306 767 4.32 / 457.48 2 11
Average= 4.20
(KJ/cycle)

Cycle 107 GMT 14/10/2022 20:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.68 29 15.14 489 215 0.21 / 449.17 2 3
2 7 2008.44 52 15.08 3120 2447 2.66 / 451.62 2 3
3 13 1021.44 16 15.04 1798 433 3.09 / 452.05 2 3
4 13 446.32 16 15.14 991 240 3.33 / 452.29 2 4
5 13 68.72 16 15.22 421 103 3.44 / 452.39 2 6
6 8 0.20 165 15.20 306 767 4.20 / 453.16 2 10
Average= 4.20
(KJ/cycle)

Cycle 106 GMT 4/10/2022 23: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.84 29 15.14 489 215 0.21 / 444.99 2 3
2 7 2008.28 52 15.08 3123 2449 2.66 / 447.44 2 3
3 13 902.36 16 15.06 1638 395 3.06 / 447.83 2 3
4 13 480.24 16 15.13 1042 252 3.31 / 448.09 2 4
5 13 77.32 16 15.21 437 106 3.42 / 448.19 2 2
6 8 0.04 165 15.19 305 764 4.18 / 448.96 2 8
Average= 4.20
(KJ/cycle)

Cycle 105 GMT 25/ 9/2022 1:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.32 29 15.14 499 219 0.22 / 440.71 2 3
2 7 2011.76 53 15.06 3114 2486 2.70 / 443.19 2 2
3 13 1002.72 16 15.04 1778 428 3.13 / 443.62 2 4
4 13 560.24 16 15.10 1158 280 3.41 / 443.90 2 4
5 13 57.76 16 15.21 408 99 3.51 / 444.00 2 4
6 8 0.24 165 15.19 309 774 4.29 / 444.78 2 5
Average= 4.20
(KJ/cycle)

Cycle 104 GMT 15/ 9/2022 3:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 29 15.17 493 217 0.22 / 436.45 2 3
2 7 2010.72 53 15.08 3122 2495 2.71 / 438.94 2 3
3 13 1019.04 16 15.04 1794 432 3.14 / 439.37 2 3
4 13 446.64 16 15.14 991 240 3.38 / 439.61 2 4
5 13 67.28 16 15.22 427 104 3.49 / 439.72 2 4
6 8 0.04 165 15.19 308 772 4.26 / 440.49 2 11
Average= 4.20
(KJ/cycle)

Cycle 103 GMT 5/ 9/2022 6:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.08 29 15.15 496 218 0.22 / 432.22 2 3
2 7 2009.52 53 15.10 3128 2503 2.72 / 434.72 2 3
3 13 902.00 16 15.07 1633 394 3.12 / 435.11 2 3
4 13 479.96 16 15.14 1044 253 3.37 / 435.37 2 3
5 13 40.84 16 15.23 380 93 3.46 / 435.46 2 4
6 8 0.04 165 15.21 307 770 4.23 / 436.23 2 9
Average= 4.19
(KJ/cycle)

Cycle 102 GMT 26/ 8/2022 8:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.40 29 15.15 498 219 0.22 / 427.96 2 3
2 7 2012.36 53 15.08 3131 2502 2.72 / 430.46 2 2
3 13 1018.36 16 15.04 1796 432 3.15 / 430.89 2 3
4 13 443.48 16 15.13 993 240 3.39 / 431.13 2 4
5 13 61.36 16 15.22 407 99 3.49 / 431.23 2 3
6 8 0.04 165 15.19 306 767 4.26 / 432.00 2 6
Average= 4.19
(KJ/cycle)

Cycle 101 GMT 16/ 8/2022 10:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 29 15.15 494 217 0.22 / 423.69 2 3
2 7 2008.48 53 15.08 3128 2500 2.72 / 426.19 2 3
3 13 1004.96 16 15.05 1777 428 3.14 / 426.62 2 3
4 13 442.88 16 15.15 989 240 3.38 / 426.86 2 4
5 13 63.12 16 15.23 415 101 3.49 / 426.96 2 5
6 8 0.08 165 15.21 309 775 4.26 / 427.74 2 6
Average= 4.19
(KJ/cycle)

Cycle 100 GMT 6/ 8/2022 13:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 29 15.15 492 216 0.22 / 419.50 2 2
2 7 2011.96 53 15.08 3135 2506 2.72 / 422.00 2 3
3 13 896.88 16 15.07 1632 394 3.12 / 422.40 2 3
4 13 361.08 16 15.17 872 212 3.33 / 422.61 2 4
5 13 50.40 16 15.23 399 97 3.42 / 422.70 2 3
6 8 0.04 165 15.20 308 772 4.20 / 423.48 2 11
Average= 4.19
(KJ/cycle)

Cycle 99 GMT 27/ 7/2022 15:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.44 29 15.14 497 218 0.22 / 415.22 2 3
2 7 2006.92 53 15.08 3147 2515 2.73 / 417.73 2 2
3 13 1006.52 16 15.05 1788 431 3.16 / 418.16 2 4
4 13 436.84 16 15.15 982 238 3.40 / 418.40 2 4
5 13 62.32 16 15.23 416 101 3.50 / 418.50 2 3
6 8 0.12 165 15.21 311 781 4.28 / 419.28 2 10
Average= 4.19
(KJ/cycle)

Cycle 98 GMT 17/ 7/2022 17:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.28 29 15.16 487 214 0.21 / 410.99 2 3
2 7 2008.64 53 15.09 3128 2502 2.72 / 413.49 2 3
3 13 898.56 16 15.07 1637 395 3.11 / 413.89 2 4
4 13 473.40 16 15.14 1039 252 3.36 / 414.14 2 4
5 13 40.80 16 15.24 379 92 3.45 / 414.23 2 3
6 8 0.12 165 15.20 305 765 4.22 / 415.00 2 12
Average= 4.19
(KJ/cycle)

Cycle 97 GMT 7/ 7/2022 20: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.80 29 15.16 494 217 0.22 / 406.78 2 3
2 7 2008.00 53 15.09 3132 2505 2.72 / 409.28 2 3
3 13 884.60 16 15.08 1617 390 3.11 / 409.67 2 4
4 13 460.56 16 15.15 1018 247 3.36 / 409.92 2 4
5 13 38.52 16 15.24 374 91 3.45 / 410.01 2 4
6 8 0.00 165 15.20 305 765 4.22 / 410.78 2 8
Average= 4.19
(KJ/cycle)

Cycle 96 GMT 27/ 6/2022 22:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 29 15.17 463 204 0.20 / 402.52 2 3
2 7 2008.92 53 15.08 3133 2504 2.71 / 405.02 2 3
3 13 1010.08 16 15.06 1789 431 3.14 / 405.45 2 4
4 13 431.88 16 15.16 976 237 3.38 / 405.69 2 3
5 13 62.56 16 15.24 419 102 3.48 / 405.79 2 4
6 8 0.08 165 15.21 308 773 4.25 / 406.56 2 11
Average= 4.19
(KJ/cycle)

Cycle 95 GMT 18/ 6/2022 0:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.92 29 15.16 500 220 0.22 / 398.30 2 3
2 7 2005.68 53 15.09 3131 2504 2.72 / 400.80 2 3
3 13 888.32 16 15.09 1619 391 3.11 / 401.19 2 4
4 13 467.68 16 15.16 1028 249 3.36 / 401.44 2 4
5 13 76.92 16 15.24 438 107 3.47 / 401.55 2 3
6 8 0.16 165 15.22 304 763 4.23 / 402.31 2 8
Average= 4.19
(KJ/cycle)

Cycle 94 GMT 8/ 6/2022 3:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 29 15.16 473 208 0.21 / 394.03 2 3
2 7 2007.44 53 15.09 3132 2505 2.71 / 396.54 2 3
3 13 1010.68 16 15.07 1798 434 3.15 / 396.97 2 4
4 13 433.76 16 15.16 989 240 3.39 / 397.21 2 4
5 13 70.52 16 15.24 431 105 3.49 / 397.31 2 3
6 8 -0.08 165 15.21 304 763 4.25 / 398.08 2 10
Average= 4.19
(KJ/cycle)

Cycle 93 GMT 29/ 5/2022 5:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.76 29 15.16 491 216 0.22 / 389.78 2 3
2 7 2007.40 53 15.10 3134 2508 2.72 / 392.29 2 3
3 13 1004.20 16 15.06 1781 429 3.15 / 392.72 2 3
4 13 432.08 16 15.16 976 237 3.39 / 392.96 2 3
5 13 73.68 16 15.23 436 106 3.50 / 393.06 2 3
6 8 0.12 165 15.21 303 760 4.26 / 393.82 2 5
Average= 4.19
(KJ/cycle)

Cycle 92 GMT 19/ 5/2022 7:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 29 15.14 485 213 0.21 / 385.51 2 3
2 7 2007.76 54 15.10 3126 2549 2.76 / 388.06 2 3
3 13 882.24 16 15.08 1611 389 3.15 / 388.45 2 3
4 13 456.00 16 15.15 1008 244 3.39 / 388.69 2 4
5 13 76.16 16 15.24 435 106 3.50 / 388.80 2 3
6 8 0.08 165 15.21 306 768 4.27 / 389.57 2 4
Average= 4.19
(KJ/cycle)

Cycle 91 GMT 9/ 5/2022 10:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 29 15.16 463 204 0.20 / 381.28 2 3
2 7 2004.16 53 15.09 3114 2490 2.69 / 383.77 2 3
3 13 1008.00 16 15.05 1781 429 3.12 / 384.20 2 3
4 13 434.64 16 15.15 979 237 3.36 / 384.44 2 4
5 13 75.00 16 15.23 432 105 3.47 / 384.54 2 3
6 8 0.08 165 15.20 301 755 4.22 / 385.30 2 13
Average= 4.19
(KJ/cycle)

Cycle 90 GMT 29/ 4/2022 12:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.28 29 15.16 483 212 0.21 / 377.05 2 3
2 7 2012.24 53 15.09 3138 2510 2.72 / 379.56 2 3
3 13 896.32 16 15.08 1631 394 3.12 / 379.95 2 4
4 13 464.68 16 15.15 1018 247 3.36 / 380.20 2 3
5 13 77.80 16 15.23 441 107 3.47 / 380.31 2 2
6 8 0.24 165 15.20 307 770 4.24 / 381.08 2 3
Average= 4.19
(KJ/cycle)

Cycle 89 GMT 19/ 4/2022 14:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.04 29 15.16 487 214 0.21 / 372.81 2 3
2 7 2003.48 53 15.10 3128 2503 2.72 / 375.31 2 3
3 13 1001.12 16 15.07 1776 428 3.15 / 375.74 2 3
4 13 421.56 16 15.17 959 233 3.38 / 375.97 2 3
5 13 66.20 16 15.24 424 103 3.48 / 376.07 2 4
6 8 0.04 165 15.21 304 763 4.24 / 376.84 2 10
Average= 4.19
(KJ/cycle)

Cycle 88 GMT 9/ 4/2022 17:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 29 15.15 464 204 0.20 / 368.57 2 3
2 7 2004.52 53 15.10 3124 2500 2.70 / 371.07 2 3
3 13 996.56 16 15.05 1765 425 3.13 / 371.49 2 3
4 13 425.84 16 15.16 971 236 3.36 / 371.73 2 4
5 13 66.68 16 15.24 421 103 3.47 / 371.83 2 6
6 8 0.00 165 15.21 303 760 4.23 / 372.59 2 8
Average= 4.19
(KJ/cycle)

Cycle 87 GMT 30/ 3/2022 19:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.08 29 15.15 486 214 0.21 / 363.90 2 3
2 7 2004.28 53 15.10 3133 2507 2.72 / 366.41 2 3
3 13 895.20 16 15.09 1634 395 3.12 / 366.80 2 4
4 13 475.68 16 15.16 1039 252 3.37 / 367.06 2 4
5 13 105.64 16 15.23 483 118 3.49 / 367.17 2 3
6 13 32.16 16 15.24 362 88 3.57 / 367.26 2 3
7 8 0.40 165 15.21 304 763 4.34 / 368.02 2 14
8 14 0.40 75 15.18 299 340 4.68 / 368.36 3 23
Average= 4.19
(KJ/cycle)

Cycle 86 GMT 20/ 3/2022 21:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 29 15.15 474 208 0.21 / 359.62 2 3
2 7 2007.04 53 15.10 3124 2500 2.71 / 362.12 2 3
3 13 1005.92 16 15.06 1785 430 3.14 / 362.55 2 3
4 13 559.44 16 15.13 1160 281 3.42 / 362.83 2 4
5 13 61.76 16 15.24 410 100 3.52 / 362.93 2 4
6 8 -0.04 165 15.21 302 758 4.28 / 363.69 2 5
Average= 4.18
(KJ/cycle)

Cycle 85 GMT 11/ 3/2022 0:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 29 15.17 455 200 0.20 / 354.96 2 3
2 7 2003.00 53 15.10 3122 2499 2.70 / 357.46 2 3
3 13 998.84 16 15.07 1778 429 3.13 / 357.89 2 3
4 13 434.08 16 15.16 977 237 3.36 / 358.12 2 3
5 13 59.32 16 15.24 407 99 3.46 / 358.22 2 3
6 13 14.40 16 15.24 336 82 3.55 / 358.30 2 4
7 8 -0.04 165 15.20 304 762 4.31 / 359.07 2 9
8 14 -0.04 75 15.16 303 345 4.65 / 359.41 3 14
Average= 4.18
(KJ/cycle)

Cycle 84 GMT 1/ 3/2022 2:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 29 15.17 470 207 0.21 / 350.77 2 3
2 7 2004.04 54 15.11 3119 2545 2.75 / 353.31 2 3
3 13 869.36 16 15.11 1598 386 3.14 / 353.70 2 4
4 13 326.52 16 15.20 819 199 3.34 / 353.90 2 4
5 13 41.64 16 15.25 381 93 3.43 / 353.99 2 4
6 8 0.16 165 15.22 306 768 4.20 / 354.76 2 8
Average= 4.17
(KJ/cycle)

Cycle 83 GMT 19/ 2/2022 4:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 29 15.17 458 201 0.20 / 346.53 2 3
2 7 2006.28 53 15.09 3125 2499 2.70 / 349.03 2 3
3 13 907.68 16 15.08 1650 398 3.10 / 349.43 2 3
4 13 482.40 16 15.15 1048 254 3.35 / 349.68 2 3
5 13 80.92 16 15.23 447 109 3.46 / 349.79 2 4
6 8 0.20 165 15.21 307 770 4.23 / 350.56 2 14
Average= 4.17
(KJ/cycle)

Cycle 82 GMT 9/ 2/2022 7: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 29 15.17 453 199 0.20 / 342.31 2 3
2 7 2003.52 53 15.10 3114 2492 2.69 / 344.81 2 3
3 13 885.20 16 15.09 1615 390 3.08 / 345.20 2 4
4 13 461.20 16 15.16 1017 247 3.33 / 345.44 2 3
5 13 73.68 16 15.25 434 106 3.43 / 345.55 2 6
6 8 -0.04 165 15.22 310 779 4.21 / 346.33 2 4
Average= 4.17
(KJ/cycle)

Cycle 81 GMT 30/ 1/2022 9:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.12 29 15.17 489 215 0.22 / 338.12 2 3
2 7 2007.92 52 15.11 3130 2459 2.67 / 340.58 2 3
3 13 1005.96 16 15.07 1782 430 3.10 / 341.00 2 3
4 13 426.60 16 15.17 975 237 3.34 / 341.24 2 4
5 13 64.68 16 15.25 420 102 3.44 / 341.34 2 5
6 8 0.16 165 15.22 307 771 4.21 / 342.12 2 6
Average= 4.17
(KJ/cycle)

Cycle 80 GMT 20/ 1/2022 11:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.08 29 15.19 484 213 0.21 / 333.90 2 3
2 7 2005.00 53 15.10 3121 2498 2.71 / 336.40 2 3
3 13 877.92 16 15.09 1608 388 3.10 / 336.79 2 3
4 13 446.60 16 15.16 996 242 3.34 / 337.03 2 4
5 13 63.60 16 15.24 413 101 3.44 / 337.13 2 4
6 8 0.12 165 15.22 306 768 4.21 / 337.90 2 6
Average= 4.17
(KJ/cycle)

Cycle 79 GMT 10/ 1/2022 14: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.88 29 15.16 477 210 0.21 / 329.66 2 3
2 7 2003.72 53 15.11 3125 2503 2.71 / 332.17 2 3
3 13 997.16 16 15.08 1771 427 3.14 / 332.59 2 4
4 13 430.04 16 15.18 971 236 3.38 / 332.83 2 3
5 13 67.60 16 15.26 420 103 3.48 / 332.93 2 3
6 8 0.08 165 15.23 302 759 4.24 / 333.69 2 7
Average= 4.17
(KJ/cycle)

Cycle 78 GMT 31/12/2021 16:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 29 15.19 460 203 0.20 / 325.07 2 3
2 7 2012.28 53 15.09 3132 2505 2.71 / 327.58 2 3
3 13 1003.12 16 15.07 1784 430 3.14 / 328.01 2 4
4 13 430.12 16 15.17 974 236 3.37 / 328.24 2 4
5 13 62.68 16 15.26 417 102 3.48 / 328.34 2 3
6 8 -0.08 165 15.23 305 766 4.24 / 329.11 2 5
7 14 -0.08 75 15.19 301 343 4.59 / 329.45 3 16
Average= 4.17
(KJ/cycle)

Cycle 77 GMT 21/12/2021 18:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.00 29 15.20 492 217 0.22 / 320.85 2 3
2 7 2008.44 53 15.11 3128 2505 2.72 / 323.35 2 2
3 13 880.80 16 15.12 1614 390 3.11 / 323.74 2 3
4 13 458.84 16 15.19 1011 246 3.36 / 323.99 2 4
5 13 71.80 16 15.27 438 107 3.47 / 324.09 2 2
6 8 0.16 165 15.24 308 774 4.24 / 324.87 2 15
Average= 4.16
(KJ/cycle)

Cycle 76 GMT 11/12/2021 20:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.92 29 15.20 487 215 0.21 / 316.66 2 3
2 7 2005.84 52 15.12 3132 2463 2.68 / 319.12 2 3
3 13 882.48 16 15.12 1608 389 3.07 / 319.51 2 3
4 13 464.60 16 15.19 1016 247 3.31 / 319.76 2 3
5 13 71.44 16 15.27 426 104 3.42 / 319.86 2 4
6 8 0.12 165 15.25 305 767 4.18 / 320.63 2 10
Average= 4.16
(KJ/cycle)

Cycle 75 GMT 1/12/2021 23:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 29 15.20 489 216 0.22 / 312.46 2 3
2 7 2005.92 52 15.11 3123 2454 2.67 / 314.91 2 2
3 13 1003.16 16 15.09 1777 429 3.10 / 315.34 2 3
4 13 424.88 16 15.19 960 233 3.33 / 315.57 2 4
5 13 65.24 16 15.28 416 102 3.43 / 315.67 2 3
6 8 0.00 165 15.25 306 770 4.20 / 316.44 2 8
Average= 4.16
(KJ/cycle)

Cycle 74 GMT 22/11/2021 1:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 29 15.20 483 213 0.21 / 308.19 2 3
2 7 2011.04 53 15.12 3134 2511 2.72 / 310.70 2 3
3 13 1011.40 16 15.10 1787 432 3.16 / 311.13 2 3
4 13 442.64 16 15.20 987 240 3.40 / 311.37 2 4
5 13 72.16 16 15.28 427 104 3.50 / 311.48 2 3
6 8 0.24 165 15.25 304 765 4.27 / 312.24 2 9
Average= 4.16
(KJ/cycle)

Cycle 73 GMT 12/11/2021 4: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.00 29 15.21 492 217 0.22 / 303.93 2 3
2 7 2009.80 53 15.12 3123 2503 2.72 / 306.43 2 3
3 13 1010.40 16 15.10 1791 433 3.15 / 306.87 2 4
4 13 438.76 16 15.19 976 237 3.39 / 307.10 2 3
5 13 67.08 16 15.27 422 103 3.49 / 307.21 2 4
6 8 0.16 165 15.25 306 770 4.26 / 307.98 2 5
Average= 4.16
(KJ/cycle)

Cycle 72 GMT 2/11/2021 6:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.04 29 15.22 489 216 0.22 / 299.69 2 3
2 7 2011.00 53 15.12 3132 2510 2.73 / 302.20 2 3
3 13 891.04 16 15.12 1622 392 3.12 / 302.59 2 3
4 13 467.44 16 15.19 1022 248 3.37 / 302.84 2 4
5 13 78.72 16 15.28 438 107 3.47 / 302.95 2 3
6 8 0.00 165 15.26 304 765 4.24 / 303.71 2 5
Average= 4.16
(KJ/cycle)

Cycle 71 GMT 23/10/2021 8:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.36 29 15.21 499 220 0.22 / 295.44 2 3
2 7 2004.76 53 15.12 3115 2496 2.72 / 297.93 2 3
3 13 1000.24 16 15.10 1775 429 3.15 / 298.36 2 3
4 13 426.52 16 15.21 966 235 3.38 / 298.60 2 3
5 13 66.40 16 15.28 423 103 3.48 / 298.70 2 4
6 8 0.16 165 15.26 307 773 4.26 / 299.47 2 11
Average= 4.16
(KJ/cycle)

Cycle 70 GMT 13/10/2021 11: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 29 15.22 473 209 0.21 / 291.20 2 3
2 7 2004.80 54 15.12 3116 2544 2.75 / 293.74 2 3
3 13 879.64 16 15.12 1601 387 3.14 / 294.13 2 3
4 13 331.00 16 15.22 823 200 3.34 / 294.33 2 4
5 13 87.40 16 15.28 459 112 3.45 / 294.44 2 5
6 8 -0.04 165 15.26 308 776 4.23 / 295.22 2 6
Average= 4.16
(KJ/cycle)

Cycle 69 GMT 3/10/2021 13:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.92 29 15.22 490 216 0.22 / 286.99 2 2
2 7 2008.68 52 15.12 3124 2456 2.67 / 289.44 2 3
3 13 1003.28 16 15.11 1774 429 3.10 / 289.87 2 3
4 13 434.00 16 15.22 975 237 3.34 / 290.11 2 4
5 13 64.32 16 15.30 414 101 3.44 / 290.21 2 3
6 8 0.20 165 15.27 309 779 4.22 / 290.99 2 9
Average= 4.16
(KJ/cycle)

Cycle 68 GMT 23/ 9/2021 15:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.08 29 15.23 495 219 0.22 / 282.77 2 3
2 7 2002.80 52 15.13 3126 2459 2.68 / 285.23 2 3
3 13 994.96 16 15.12 1763 427 3.10 / 285.65 2 3
4 13 422.40 16 15.23 956 233 3.34 / 285.89 2 3
5 13 66.44 16 15.29 423 103 3.44 / 285.99 2 4
6 8 0.00 165 15.27 310 781 4.22 / 286.77 2 8
Average= 4.16
(KJ/cycle)

Cycle 67 GMT 13/ 9/2021 18: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.44 29 15.24 495 219 0.22 / 278.51 2 3
2 7 2010.76 53 15.13 3115 2498 2.72 / 281.00 2 3
3 13 1002.84 16 15.12 1772 429 3.15 / 281.43 2 4
4 13 426.24 16 15.23 964 235 3.38 / 281.67 2 3
5 13 62.56 16 15.31 417 102 3.48 / 281.77 2 5
6 8 0.20 165 15.28 309 779 4.26 / 282.55 2 4
Average= 4.16
(KJ/cycle)

Cycle 66 GMT 3/ 9/2021 20:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.08 29 15.24 496 219 0.22 / 274.32 2 3
2 7 2002.96 52 15.13 3121 2455 2.67 / 276.77 2 3
3 13 879.36 16 15.16 1601 388 3.06 / 277.16 2 4
4 13 457.88 16 15.23 1012 247 3.31 / 277.41 2 3
5 13 71.44 16 15.32 432 106 3.42 / 277.51 2 3
6 8 0.00 165 15.29 307 775 4.19 / 278.29 2 6
Average= 4.15
(KJ/cycle)

Cycle 65 GMT 24/ 8/2021 22:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.36 28 15.24 495 211 0.21 / 270.07 2 2
2 7 2011.56 53 15.13 3128 2508 2.72 / 272.58 2 2
3 13 887.08 16 15.16 1613 391 3.11 / 272.97 2 3
4 13 456.04 16 15.23 1003 244 3.36 / 273.22 2 4
5 13 70.04 16 15.32 431 106 3.46 / 273.32 2 3
6 8 0.08 165 15.30 306 772 4.23 / 274.10 2 8
Average= 4.15
(KJ/cycle)

Cycle 64 GMT 15/ 8/2021 0:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 28 15.25 470 201 0.20 / 265.79 2 3
2 7 2008.00 53 15.14 3132 2513 2.71 / 268.31 2 3
3 13 1000.12 16 15.12 1772 429 3.14 / 268.74 2 4
4 13 438.48 16 15.23 983 240 3.38 / 268.98 2 3
5 13 65.36 16 15.31 423 104 3.49 / 269.08 2 5
6 8 0.16 165 15.29 311 785 4.27 / 269.86 2 7
Average= 4.15
(KJ/cycle)

Cycle 63 GMT 5/ 8/2021 3:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 28 15.25 486 208 0.21 / 261.55 2 3
2 7 2004.20 53 15.14 3119 2503 2.71 / 264.05 2 3
3 13 995.84 16 15.13 1766 428 3.14 / 264.48 2 4
4 13 426.04 16 15.25 965 235 3.37 / 264.71 2 4
5 13 60.76 16 15.33 415 102 3.48 / 264.82 2 3
6 8 -0.16 165 15.30 308 778 4.25 / 265.59 2 7
Average= 4.15
(KJ/cycle)

Cycle 62 GMT 26/ 7/2021 5:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 28 15.27 489 209 0.21 / 256.88 2 3
2 7 2006.16 54 15.15 3128 2559 2.77 / 259.44 2 3
3 13 1002.12 16 15.14 1775 430 3.20 / 259.87 2 4
4 13 410.52 16 15.26 942 230 3.43 / 260.10 2 3
5 13 55.24 16 15.34 406 100 3.53 / 260.20 2 3
6 8 0.16 165 15.31 312 788 4.32 / 260.98 2 7
7 14 0.16 75 15.27 311 356 4.67 / 261.34 3 13
Average= 4.15
(KJ/cycle)

Cycle 61 GMT 16/ 7/2021 7:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 28 15.26 496 212 0.21 / 252.64 2 3
2 7 2002.92 53 15.14 3117 2501 2.71 / 255.14 2 3
3 13 987.44 16 15.15 1752 425 3.14 / 255.57 2 4
4 13 421.84 16 15.27 961 235 3.37 / 255.80 2 4
5 13 31.16 16 15.36 366 90 3.46 / 255.89 2 3
6 8 0.16 165 15.32 307 776 4.24 / 256.67 2 10
Average= 4.14
(KJ/cycle)

Cycle 60 GMT 6/ 7/2021 10:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.60 28 15.26 493 211 0.21 / 248.41 2 3
2 7 2008.08 53 15.15 3127 2511 2.72 / 250.92 2 3
3 13 891.60 16 15.17 1623 394 3.12 / 251.31 2 4
4 13 462.80 16 15.24 1013 247 3.36 / 251.56 2 3
5 13 35.28 16 15.34 372 91 3.45 / 251.65 2 3
6 8 0.00 165 15.31 309 781 4.23 / 252.43 2 5
Average= 4.14
(KJ/cycle)

Cycle 59 GMT 26/ 6/2021 12:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 28 15.27 488 209 0.21 / 244.23 2 3
2 7 2005.88 52 15.15 3110 2450 2.66 / 246.68 2 2
3 13 883.00 16 15.19 1619 393 3.05 / 247.07 2 4
4 13 457.40 16 15.26 1010 247 3.30 / 247.32 2 4
5 13 37.24 16 15.36 380 93 3.39 / 247.41 2 5
6 8 0.16 165 15.32 310 784 4.18 / 248.20 2 14
Average= 4.14
(KJ/cycle)

Cycle 58 GMT 16/ 6/2021 14:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.08 28 15.28 495 212 0.21 / 239.98 2 3
2 7 2005.00 53 15.16 3118 2505 2.72 / 242.49 2 3
3 13 888.88 16 15.18 1621 394 3.11 / 242.88 2 3
4 13 458.04 16 15.27 1015 248 3.36 / 243.13 2 3
5 13 65.24 16 15.34 425 104 3.46 / 243.24 2 3
6 8 0.12 165 15.33 310 784 4.25 / 244.02 2 10
Average= 4.14
(KJ/cycle)

Cycle 57 GMT 6/ 6/2021 17: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.20 28 15.27 487 208 0.21 / 235.74 2 3
2 7 2002.88 53 15.17 3122 2510 2.72 / 238.25 2 3
3 13 875.40 16 15.21 1601 390 3.11 / 238.64 2 3
4 13 451.52 16 15.29 1003 245 3.35 / 238.89 2 3
5 13 66.72 16 15.36 423 104 3.46 / 238.99 2 3
6 8 0.16 165 15.34 309 782 4.24 / 239.77 2 4
Average= 4.13
(KJ/cycle)

Cycle 56 GMT 27/ 5/2021 19:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.04 28 15.28 489 209 0.21 / 231.49 2 3
2 7 2002.96 53 15.16 3122 2508 2.72 / 234.00 2 3
3 13 994.84 16 15.17 1760 427 3.14 / 234.43 2 4
4 13 434.60 16 15.28 978 239 3.38 / 234.67 2 4
5 13 64.28 16 15.36 414 102 3.49 / 234.77 2 4
6 8 0.16 165 15.33 303 766 4.25 / 235.53 2 11
Average= 4.13
(KJ/cycle)

Cycle 55 GMT 17/ 5/2021 21:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 28 15.29 465 199 0.20 / 227.26 2 3
2 7 2003.12 53 15.17 3113 2503 2.70 / 229.77 2 3
3 13 889.36 16 15.20 1622 394 3.10 / 230.16 2 4
4 13 461.56 16 15.28 1015 248 3.34 / 230.41 2 4
5 13 41.60 16 15.36 380 93 3.44 / 230.50 2 2
6 8 0.04 165 15.34 308 780 4.22 / 231.28 2 9
Average= 4.13
(KJ/cycle)

Cycle 54 GMT 7/ 5/2021 23:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 28 15.30 464 199 0.20 / 223.05 2 3
2 7 2003.40 53 15.17 3111 2501 2.70 / 225.55 2 2
3 13 877.48 16 15.19 1601 389 3.09 / 225.94 2 4
4 13 445.96 16 15.28 993 243 3.33 / 226.18 2 4
5 13 68.48 16 15.37 424 104 3.44 / 226.28 2 5
6 8 0.04 165 15.33 308 779 4.22 / 227.06 2 11
Average= 4.13
(KJ/cycle)

Cycle 53 GMT 28/ 4/2021 2:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 28 15.28 452 193 0.19 / 218.80 2 3
2 7 2003.00 53 15.18 3118 2509 2.70 / 221.30 2 3
3 13 991.32 16 15.19 1757 427 3.13 / 221.73 2 3
4 13 410.04 16 15.31 939 230 3.36 / 221.96 2 4
5 13 64.08 16 15.37 417 103 3.46 / 222.06 2 4
6 8 0.16 165 15.34 310 785 4.25 / 222.85 2 10
Average= 4.13
(KJ/cycle)

Cycle 52 GMT 18/ 4/2021 4:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.84 28 15.29 483 207 0.21 / 214.57 2 3
2 7 2010.84 53 15.16 3117 2504 2.71 / 217.08 2 2
3 13 891.68 16 15.20 1620 394 3.11 / 217.47 2 3
4 13 460.76 16 15.28 1013 248 3.35 / 217.72 2 4
5 13 76.96 16 15.36 442 109 3.46 / 217.83 2 5
6 8 0.12 165 15.34 306 775 4.24 / 218.60 2 4
Average= 4.12
(KJ/cycle)

Cycle 51 GMT 8/ 4/2021 6:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.52 28 15.28 481 206 0.21 / 210.38 2 3
2 7 2003.16 52 15.17 3105 2449 2.66 / 212.83 2 3
3 13 991.28 16 15.18 1759 427 3.08 / 213.26 2 3
4 13 416.80 16 15.29 950 232 3.31 / 213.49 2 3
5 13 64.84 16 15.37 418 103 3.42 / 213.59 2 3
6 8 -0.04 165 15.34 305 772 4.19 / 214.37 2 5
Average= 4.12
(KJ/cycle)

Cycle 50 GMT 29/ 3/2021 9: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 28 15.30 449 192 0.19 / 205.79 2 3
2 7 2011.84 53 15.17 3120 2509 2.70 / 208.30 2 3
3 13 996.08 16 15.19 1767 429 3.13 / 208.73 2 4
4 13 420.76 16 15.30 955 234 3.36 / 208.96 2 4
5 13 62.52 16 15.38 412 101 3.47 / 209.07 2 3
6 8 0.16 165 15.35 302 765 4.23 / 209.83 2 10
7 14 0.16 75 15.32 301 346 4.58 / 210.18 3 8
Average= 4.12
(KJ/cycle)

Cycle 49 GMT 19/ 3/2021 11:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.88 28 15.30 474 203 0.20 / 201.56 2 3
2 7 2005.80 53 15.17 3119 2508 2.71 / 204.07 2 3
3 13 999.08 16 15.19 1766 429 3.14 / 204.50 2 4
4 13 423.96 16 15.31 959 235 3.37 / 204.73 2 3
5 13 60.72 16 15.39 409 101 3.48 / 204.83 2 3
6 8 0.12 165 15.35 303 767 4.24 / 205.60 2 4
Average= 4.11
(KJ/cycle)

Cycle 48 GMT 9/ 3/2021 13:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 28 15.30 449 192 0.19 / 197.44 2 3
2 7 2006.80 52 15.18 3117 2460 2.65 / 199.91 2 3
3 13 877.60 16 15.21 1599 389 3.04 / 200.29 2 3
4 13 337.84 16 15.32 832 204 3.25 / 200.50 2 3
5 13 51.64 16 15.38 393 97 3.34 / 200.59 2 3
6 8 0.00 165 15.35 301 762 4.10 / 201.36 2 4
Average= 4.11
(KJ/cycle)

Cycle 47 GMT 27/ 2/2021 15:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 28 15.31 476 204 0.20 / 193.24 2 3
2 7 2006.48 53 15.16 3115 2503 2.71 / 195.74 2 3
3 13 880.44 16 15.21 1602 390 3.10 / 196.13 2 3
4 13 460.84 16 15.30 1007 247 3.34 / 196.38 2 3
5 13 75.28 16 15.38 433 107 3.45 / 196.49 2 3
6 8 0.12 165 15.35 302 765 4.21 / 197.25 2 9
Average= 4.11
(KJ/cycle)

Cycle 46 GMT 17/ 2/2021 18: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.28 28 15.30 479 205 0.21 / 189.00 2 3
2 7 2010.12 53 15.18 3115 2506 2.71 / 191.50 2 2
3 13 1007.40 16 15.19 1767 429 3.14 / 191.93 2 3
4 13 426.36 16 15.32 959 235 3.38 / 192.17 2 3
5 13 63.92 16 15.39 413 102 3.48 / 192.27 2 2
6 8 0.08 165 15.36 303 768 4.25 / 193.04 2 11
Average= 4.11
(KJ/cycle)

Cycle 45 GMT 7/ 2/2021 20:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.28 28 15.32 469 201 0.20 / 184.78 2 3
2 7 2006.44 53 15.17 3114 2504 2.70 / 187.28 2 2
3 13 886.48 16 15.22 1612 393 3.10 / 187.67 2 3
4 13 463.44 16 15.29 1014 248 3.35 / 187.92 2 3
5 13 76.24 16 15.38 435 107 3.45 / 188.03 2 3
6 8 0.20 165 15.35 301 762 4.21 / 188.79 2 4
Average= 4.10
(KJ/cycle)

Cycle 44 GMT 28/ 1/2021 22:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.60 28 15.31 487 209 0.21 / 180.57 2 3
2 7 2003.72 53 15.19 3099 2495 2.70 / 183.06 2 2
3 13 989.60 16 15.20 1753 426 3.13 / 183.49 2 4
4 13 417.84 16 15.32 944 231 3.36 / 183.72 2 3
5 13 62.32 16 15.38 408 100 3.46 / 183.82 2 4
6 8 0.00 165 15.36 299 758 4.22 / 184.58 2 3
Average= 4.10
(KJ/cycle)

Cycle 43 GMT 19/ 1/2021 0:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.72 28 15.32 487 209 0.21 / 176.27 2 3
2 7 2002.08 53 15.18 3108 2501 2.71 / 178.77 2 2
3 13 1000.84 16 15.20 1773 431 3.14 / 179.20 2 3
4 13 554.04 16 15.28 1141 279 3.42 / 179.48 2 4
5 13 57.00 16 15.39 402 99 3.52 / 179.58 2 3
6 8 0.12 165 15.36 306 776 4.29 / 180.36 2 7
Average= 4.10
(KJ/cycle)

Cycle 42 GMT 9/ 1/2021 3: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.36 28 15.33 478 205 0.21 / 172.16 2 3
2 7 2003.16 52 15.19 3105 2453 2.66 / 174.61 2 2
3 13 885.24 16 15.23 1607 392 3.05 / 175.00 2 3
4 13 340.20 16 15.35 836 205 3.25 / 175.21 2 4
5 13 48.80 16 15.41 390 96 3.35 / 175.30 2 4
6 8 0.04 165 15.37 300 761 4.11 / 176.06 2 12
Average= 4.09
(KJ/cycle)

Cycle 41 GMT 30/12/2020 5: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.36 28 15.32 485 208 0.21 / 167.93 2 3
2 7 2006.24 53 15.18 3119 2509 2.72 / 170.44 2 3
3 13 878.24 16 15.23 1597 389 3.11 / 170.83 2 4
4 13 452.40 16 15.31 994 243 3.35 / 171.07 2 4
5 13 69.12 16 15.39 422 104 3.45 / 171.18 2 4
6 8 0.20 165 15.36 306 776 4.23 / 171.95 2 9
Average= 4.09
(KJ/cycle)

Cycle 40 GMT 20/12/2020 7:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 28 15.33 481 206 0.21 / 163.68 2 3
2 7 2002.44 53 15.20 3111 2506 2.71 / 166.19 2 2
3 13 988.96 16 15.22 1748 426 3.14 / 166.61 2 4
4 13 407.60 16 15.33 939 230 3.37 / 166.85 2 4
5 13 59.68 16 15.41 411 101 3.47 / 166.95 2 2
6 8 0.20 165 15.37 306 776 4.25 / 167.72 2 6
Average= 4.09
(KJ/cycle)

Cycle 39 GMT 10/12/2020 9:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.20 28 15.32 488 209 0.21 / 159.50 2 3
2 7 2002.64 53 15.19 3114 2507 2.72 / 162.00 2 3
3 13 878.40 16 15.23 1595 389 3.10 / 162.39 2 3
4 13 333.52 16 15.35 830 204 3.31 / 162.59 2 3
5 13 89.56 16 15.39 461 114 3.42 / 162.71 2 6
6 8 -0.12 165 15.37 303 768 4.19 / 163.48 2 6
Average= 4.09
(KJ/cycle)

Cycle 38 GMT 30/11/2020 11:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.28 28 15.34 487 209 0.21 / 155.25 2 3
2 7 2004.04 53 15.19 3113 2506 2.72 / 157.75 2 3
3 13 986.04 16 15.22 1745 425 3.14 / 158.18 2 4
4 13 413.80 16 15.33 940 231 3.37 / 158.41 2 3
5 13 58.88 16 15.40 404 100 3.47 / 158.51 2 2
6 8 0.08 165 15.37 306 776 4.25 / 159.29 2 12
Average= 4.08
(KJ/cycle)

Cycle 37 GMT 20/11/2020 14: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.28 28 15.34 495 213 0.21 / 151.06 2 3
2 7 2009.12 53 15.19 3126 2517 2.73 / 153.58 2 3
3 13 873.12 16 15.25 1595 389 3.12 / 153.97 2 3
4 13 333.04 16 15.36 828 203 3.32 / 154.17 2 4
5 13 45.08 16 15.41 384 95 3.42 / 154.27 2 3
6 8 -0.08 165 15.38 304 771 4.19 / 155.04 2 9
Average= 4.08
(KJ/cycle)

Cycle 36 GMT 10/11/2020 16:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.04 28 15.33 490 210 0.21 / 146.86 2 3
2 7 2003.24 52 15.20 3105 2454 2.66 / 149.31 2 2
3 13 986.44 16 15.22 1749 426 3.09 / 149.74 2 3
4 13 418.44 16 15.35 945 232 3.32 / 149.97 2 4
5 13 62.64 16 15.42 413 102 3.42 / 150.07 2 6
6 8 0.08 165 15.39 307 780 4.20 / 150.85 2 3
Average= 4.08
(KJ/cycle)

Cycle 35 GMT 31/10/2020 18:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.64 28 15.34 484 208 0.21 / 142.67 2 3
2 7 2003.88 53 15.20 3093 2492 2.70 / 145.16 2 2
3 13 859.80 16 15.24 1572 383 3.08 / 145.54 2 3
4 13 431.00 16 15.33 963 236 3.32 / 145.78 2 3
5 13 58.32 16 15.41 403 99 3.42 / 145.88 2 4
6 8 0.12 165 15.38 303 769 4.19 / 146.65 2 11
Average= 4.07
(KJ/cycle)

Cycle 34 GMT 21/10/2020 20:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.64 28 15.33 493 212 0.21 / 138.49 2 2
2 7 2004.16 52 15.21 3113 2462 2.67 / 140.95 2 2
3 13 880.00 16 15.25 1597 390 3.06 / 141.34 2 3
4 13 456.92 16 15.32 1000 245 3.31 / 141.58 2 4
5 13 72.60 16 15.40 433 107 3.42 / 141.69 2 5
6 8 0.12 165 15.39 303 769 4.18 / 142.46 2 6
Average= 4.07
(KJ/cycle)

Cycle 33 GMT 11/10/2020 23: 5: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.28 28 15.34 486 209 0.21 / 134.24 2 3
2 7 2009.56 53 15.20 3118 2512 2.72 / 136.76 2 2
3 13 874.44 16 15.25 1592 388 3.11 / 137.15 2 3
4 13 457.44 16 15.33 1003 246 3.36 / 137.39 2 4
5 13 70.72 16 15.41 425 105 3.46 / 137.50 2 3
6 8 0.08 165 15.38 307 779 4.24 / 138.28 2 8
Average= 4.07
(KJ/cycle)

Cycle 32 GMT 2/10/2020 1:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.08 28 15.34 496 213 0.21 / 130.10 2 3
2 7 2003.76 52 15.20 3093 2445 2.66 / 132.54 2 3
3 13 875.80 16 15.24 1591 388 3.05 / 132.93 2 3
4 13 453.08 16 15.32 1001 245 3.29 / 133.17 2 3
5 13 33.84 16 15.42 366 90 3.38 / 133.26 2 3
6 8 0.20 165 15.38 304 771 4.15 / 134.04 2 4
Average= 4.06
(KJ/cycle)

Cycle 31 GMT 22/ 9/2020 3:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.20 28 15.35 484 208 0.21 / 125.87 2 3
2 7 2005.08 53 15.21 3112 2509 2.72 / 128.38 2 3
3 13 870.16 16 15.26 1591 388 3.11 / 128.76 2 3
4 13 442.32 16 15.34 979 240 3.35 / 129.00 2 3
5 13 65.52 16 15.41 415 102 3.45 / 129.11 2 3
6 8 0.08 165 15.39 306 777 4.22 / 129.88 2 11
Average= 4.06
(KJ/cycle)

Cycle 30 GMT 12/ 9/2020 5:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 28 15.35 482 207 0.21 / 121.69 2 3
2 7 2011.12 53 15.20 3121 2514 2.72 / 124.20 2 3
3 13 885.48 16 15.25 1608 392 3.11 / 124.59 2 4
4 13 346.60 16 15.35 840 206 3.32 / 124.80 2 4
5 13 50.60 16 15.41 386 95 3.42 / 124.89 2 3
6 8 0.08 165 15.39 301 764 4.18 / 125.66 2 13
Average= 4.05
(KJ/cycle)

Cycle 29 GMT 2/ 9/2020 7:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.80 28 15.34 486 209 0.21 / 117.59 2 3
2 7 2005.88 52 15.22 3119 2469 2.68 / 120.06 2 3
3 13 986.00 16 15.24 1738 424 3.10 / 120.48 2 3
4 13 413.08 16 15.35 941 231 3.33 / 120.71 2 4
5 8 0.32 165 15.40 302 767 4.10 / 121.48 2 4
Average= 4.05
(KJ/cycle)

Cycle 28 GMT 23/ 8/2020 10:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 28 15.36 465 200 0.20 / 113.39 2 3
2 7 2004.32 53 15.21 3106 2504 2.70 / 115.90 2 3
3 13 863.88 16 15.25 1567 382 3.09 / 116.28 2 4
4 13 435.56 16 15.34 970 238 3.32 / 116.52 2 4
5 13 62.16 16 15.42 411 101 3.43 / 116.62 2 3
6 8 -0.04 165 15.40 300 762 4.19 / 117.38 2 5
Average= 4.05
(KJ/cycle)

Cycle 27 GMT 13/ 8/2020 12:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.84 28 15.36 486 209 0.21 / 109.16 2 3
2 7 2002.28 53 15.23 3098 2501 2.71 / 111.66 2 2
3 13 987.68 16 15.25 1746 426 3.14 / 112.09 2 3
4 13 417.96 16 15.37 952 234 3.37 / 112.32 2 3
5 13 64.56 16 15.42 413 102 3.47 / 112.42 2 3
6 8 0.16 165 15.40 302 767 4.24 / 113.19 2 11
Average= 4.04
(KJ/cycle)

Cycle 26 GMT 3/ 8/2020 14:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.84 28 15.36 487 209 0.21 / 104.93 2 3
2 7 2009.60 53 15.23 3116 2515 2.72 / 107.45 2 3
3 13 885.12 16 15.27 1605 392 3.12 / 107.84 2 3
4 13 457.08 16 15.35 997 245 3.36 / 108.09 2 4
5 13 76.00 16 15.43 426 105 3.47 / 108.19 2 4
6 8 0.16 165 15.41 299 760 4.23 / 108.95 2 6
Average= 4.04
(KJ/cycle)

Cycle 25 GMT 24/ 7/2020 17: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.60 28 15.38 480 207 0.21 / 100.71 2 3
2 7 2003.96 53 15.23 3112 2512 2.72 / 103.22 2 3
3 13 871.28 16 15.29 1583 387 3.11 / 103.61 2 3
4 13 448.80 16 15.36 992 244 3.35 / 103.85 2 3
5 13 68.40 16 15.44 417 103 3.45 / 103.96 2 4
6 8 0.12 165 15.41 302 768 4.22 / 104.73 2 10
Average= 4.03
(KJ/cycle)

Cycle 24 GMT 14/ 7/2020 19:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 28 15.36 450 194 0.19 / 96.58 2 3
2 7 2003.20 52 15.23 3111 2464 2.66 / 99.04 2 3
3 13 862.80 16 15.29 1577 386 3.04 / 99.43 2 3
4 13 319.80 16 15.40 801 197 3.24 / 99.62 2 4
5 13 85.00 16 15.44 449 111 3.35 / 99.73 2 4
6 8 -0.04 165 15.42 303 771 4.12 / 100.50 2 7
Average= 4.02
(KJ/cycle)

Cycle 23 GMT 4/ 7/2020 21:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 28 15.38 472 203 0.20 / 92.03 2 3
2 7 2004.44 53 15.23 3103 2505 2.71 / 94.54 2 3
3 13 975.56 16 15.27 1717 419 3.13 / 94.96 2 3
4 13 386.36 16 15.38 896 220 3.35 / 95.18 2 3
5 13 56.16 16 15.44 398 98 3.45 / 95.28 2 4
6 8 -0.08 165 15.42 301 766 4.21 / 96.04 2 8
7 14 -0.08 75 15.38 296 341 4.55 / 96.38 3 11
Average= 4.02
(KJ/cycle)

Cycle 22 GMT 24/ 6/2020 23:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.64 28 15.37 483 208 0.21 / 87.83 2 2
2 7 2005.96 53 15.26 3121 2524 2.73 / 90.36 2 2
3 13 858.64 16 15.30 1573 385 3.12 / 90.74 2 3
4 13 425.40 16 15.37 949 233 3.35 / 90.97 2 3
5 13 63.40 16 15.45 408 101 3.45 / 91.08 2 3
6 8 0.32 165 15.43 296 754 4.20 / 91.83 2 5
Average= 3.99
(KJ/cycle)

Cycle 21 GMT 15/ 6/2020 2:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 28 15.38 452 195 0.19 / 83.64 2 3
2 7 2006.04 52 15.25 3104 2461 2.66 / 86.10 2 2
3 13 990.72 16 15.27 1747 427 3.08 / 86.53 2 3
4 13 407.36 16 15.38 932 229 3.31 / 86.76 2 3
5 13 61.28 16 15.45 408 101 3.41 / 86.86 2 3
6 8 -0.20 165 15.41 302 768 4.18 / 87.62 2 8
Average= 3.98
(KJ/cycle)

Cycle 20 GMT 5/ 6/2020 4:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.84 28 15.38 482 208 0.21 / 79.51 2 3
2 7 2004.52 53 15.25 3105 2510 2.72 / 82.02 2 2
3 13 870.08 16 15.30 1579 387 3.10 / 82.40 2 3
4 13 326.20 16 15.40 809 199 3.30 / 82.60 2 3
5 13 50.80 16 15.46 386 95 3.40 / 82.70 2 4
6 8 0.20 165 15.43 293 746 4.14 / 83.44 2 7
Average= 3.97
(KJ/cycle)

Cycle 19 GMT 26/ 5/2020 6:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.32 28 15.38 473 204 0.20 / 75.28 2 3
2 7 2006.80 53 15.25 3111 2514 2.72 / 77.79 2 2
3 13 979.12 16 15.28 1732 423 3.14 / 78.22 2 3
4 13 394.36 16 15.39 904 223 3.36 / 78.44 2 3
5 13 58.48 16 15.47 397 98 3.46 / 78.54 2 3
6 8 0.08 165 15.44 298 759 4.22 / 79.30 2 6
Average= 3.96
(KJ/cycle)

Cycle 18 GMT 16/ 5/2020 9:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.24 28 15.38 476 205 0.20 / 71.03 2 3
2 7 2004.40 54 15.24 3112 2561 2.77 / 73.59 2 2
3 13 974.76 16 15.28 1726 422 3.19 / 74.01 2 2
4 13 384.00 16 15.38 896 220 3.41 / 74.23 2 3
5 13 57.52 16 15.45 398 98 3.51 / 74.33 2 3
6 8 0.00 165 15.43 294 749 4.26 / 75.08 2 4
Average= 3.95
(KJ/cycle)

Cycle 17 GMT 6/ 5/2020 11:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.40 28 15.39 470 203 0.20 / 66.81 2 3
2 7 2008.72 53 15.26 3117 2521 2.72 / 69.33 2 2
3 13 865.00 16 15.30 1580 387 3.11 / 69.72 2 3
4 13 431.12 16 15.37 967 238 3.35 / 69.96 2 3
5 13 62.04 16 15.45 407 101 3.45 / 70.06 2 3
6 8 0.20 165 15.43 299 761 4.21 / 70.82 2 5
Average= 3.93
(KJ/cycle)

Cycle 16 GMT 26/ 4/2020 13:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 28 15.39 456 196 0.20 / 62.60 2 3
2 7 2009.04 53 15.25 3118 2520 2.72 / 65.12 2 2
3 13 859.76 18 15.29 1560 429 3.15 / 65.55 2 3
4 13 278.48 18 15.41 737 204 3.35 / 65.75 2 3
5 13 30.40 18 15.46 356 99 3.45 / 65.85 2 3
6 8 0.00 165 15.43 298 759 4.21 / 66.61 2 6
Average= 3.92
(KJ/cycle)

Cycle 15 GMT 16/ 4/2020 15:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 28 15.39 454 196 0.20 / 58.40 2 3
2 7 2005.72 53 15.26 3115 2519 2.71 / 60.92 2 2
3 13 849.08 18 15.31 1549 427 3.14 / 61.35 2 2
4 13 274.24 18 15.42 731 203 3.34 / 61.55 2 3
5 13 30.96 18 15.47 356 99 3.44 / 61.65 2 3
6 8 0.08 165 15.44 296 754 4.20 / 62.40 2 6
Average= 3.90
(KJ/cycle)

Cycle 14 GMT 6/ 4/2020 17:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.04 28 15.40 472 204 0.20 / 54.16 2 3
2 7 2004.60 53 15.25 3099 2505 2.71 / 56.67 2 2
3 13 974.60 18 15.28 1721 473 3.18 / 57.14 2 3
4 13 249.72 18 15.42 691 192 3.37 / 57.33 2 3
5 13 51.84 18 15.46 388 108 3.48 / 57.44 2 3
6 8 0.04 165 15.43 300 764 4.25 / 58.21 2 9
Average= 3.88
(KJ/cycle)

Cycle 13 GMT 27/ 3/2020 20: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.16 28 15.41 467 202 0.20 / 49.94 2 3
2 7 2007.64 53 15.26 3115 2519 2.72 / 52.46 2 2
3 13 861.60 18 15.32 1570 433 3.15 / 52.90 2 3
4 13 286.40 18 15.42 753 209 3.36 / 53.11 2 3
5 13 34.04 18 15.47 362 101 3.46 / 53.21 2 3
6 8 -0.12 165 15.44 296 754 4.22 / 53.96 2 9
Average= 3.85
(KJ/cycle)

Cycle 12 GMT 17/ 3/2020 22: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.92 27 15.39 468 194 0.19 / 45.71 2 3
2 7 2007.08 53 15.27 3113 2519 2.71 / 48.23 2 2
3 13 978.44 18 15.30 1728 476 3.19 / 48.70 2 2
4 13 247.96 18 15.45 688 191 3.38 / 48.90 2 3
5 13 29.76 18 15.48 348 97 3.48 / 48.99 2 3
6 8 0.16 165 15.45 294 749 4.23 / 49.74 2 5
Average= 3.83
(KJ/cycle)

Cycle 11 GMT 8/ 3/2020 0:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 27 15.41 446 186 0.19 / 41.52 2 3
2 7 2003.64 53 15.28 3109 2518 2.70 / 44.03 2 2
3 13 856.16 18 15.32 1559 430 3.13 / 44.46 2 3
4 13 280.96 18 15.44 738 205 3.34 / 44.67 2 3
5 13 30.44 18 15.48 351 98 3.44 / 44.77 2 3
6 8 -0.12 165 15.44 294 749 4.19 / 45.51 2 6
Average= 3.79
(KJ/cycle)

Cycle 10 GMT 27/ 2/2020 2:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.04 27 15.40 472 196 0.20 / 37.33 2 3
2 7 2006.16 53 15.28 3109 2518 2.71 / 39.85 2 2
3 13 852.68 18 15.32 1554 429 3.14 / 40.28 2 3
4 13 279.92 18 15.44 736 205 3.35 / 40.48 2 3
5 13 33.44 18 15.48 357 99 3.45 / 40.58 2 3
6 8 0.16 165 15.45 293 747 4.19 / 41.33 2 10
Average= 3.76
(KJ/cycle)

Cycle 9 GMT 17/ 2/2020 4:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.64 27 15.41 474 197 0.20 / 33.12 2 3
2 7 2003.84 53 15.28 3108 2517 2.71 / 35.64 2 2
3 13 855.52 18 15.33 1553 429 3.14 / 36.07 2 3
4 13 283.68 18 15.44 739 205 3.35 / 36.27 2 3
5 13 32.48 18 15.48 359 100 3.45 / 36.37 2 3
6 8 0.04 165 15.45 299 762 4.21 / 37.14 2 7
Average= 3.71
(KJ/cycle)

Cycle 8 GMT 7/ 2/2020 6:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.92 27 15.40 477 198 0.20 / 28.94 2 3
2 7 2007.20 53 15.28 3112 2520 2.72 / 31.46 2 2
3 13 848.52 18 15.33 1545 426 3.14 / 31.88 2 3
4 13 271.84 18 15.44 721 200 3.35 / 32.08 2 3
5 13 29.28 18 15.48 347 97 3.44 / 32.18 2 3
6 8 -0.04 165 15.45 293 747 4.19 / 32.93 2 9
Average= 3.66
(KJ/cycle)

Cycle 7 GMT 28/ 1/2020 8:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.32 27 15.41 467 194 0.19 / 24.75 2 3
2 7 2003.40 53 15.28 3102 2512 2.71 / 27.26 2 2
3 13 852.36 18 15.33 1550 428 3.13 / 27.69 2 3
4 13 274.56 18 15.43 726 202 3.34 / 27.89 2 3
5 13 26.24 18 15.48 344 96 3.43 / 27.99 2 3
6 8 0.08 165 15.44 294 749 4.18 / 28.74 2 8
Average= 3.59
(KJ/cycle)

Cycle 6 GMT 18/ 1/2020 10:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.44 26 15.40 471 189 0.19 / 20.54 2 3
2 3 1050.36 1 15.44 1907 29 0.22 / 20.57 2 2
3 7 2006.12 53 15.30 3100 2514 2.73 / 23.09 2 2
4 13 859.56 18 15.33 1550 428 3.16 / 23.51 2 3
5 13 269.36 18 15.45 716 199 3.36 / 23.71 2 3
6 13 25.84 18 15.48 340 95 3.45 / 23.81 2 3
7 8 0.16 165 15.46 293 747 4.20 / 24.56 2 12
Average= 3.51
(KJ/cycle)

Cycle 5 GMT 8/ 1/2020 12: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.08 25 15.42 470 181 0.18 / 15.80 2 3
2 10 1024.00 2 15.39 1836 57 0.24 / 15.86 2 2
3 7 2003.80 75 15.04 3055 3446 3.68 / 19.30 2 2
4 13 309.24 18 15.42 772 214 3.90 / 19.52 2 3
5 13 18.12 18 15.49 327 91 3.99 / 19.61 2 3
6 8 0.00 165 15.45 293 747 4.74 / 20.36 2 9
Average= 3.39
(KJ/cycle)

Cycle 4 GMT 29/12/2019 14:21: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.92 26 15.42 465 186 0.19 / 12.05 2 3
2 7 1507.52 74 15.18 2394 2689 2.88 / 14.74 2 3
3 13 118.40 18 15.47 489 136 3.01 / 14.87 2 3
4 8 0.16 165 15.46 293 747 3.76 / 15.62 2 6
Average= 3.12
(KJ/cycle)

Cycle 3 GMT 28/12/2019 14:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 25 15.45 466 180 0.18 / 8.27 2 3
2 7 1519.64 74 15.18 2408 2705 2.88 / 10.98 2 3
3 13 126.12 18 15.48 499 139 3.02 / 11.11 2 3
4 8 0.16 165 15.47 292 745 3.77 / 11.86 2 8
Average= 2.96
(KJ/cycle)

Cycle 2 GMT 27/12/2019 14:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.92 26 15.47 474 191 0.19 / 4.75 2 3
2 7 1369.20 74 15.25 2211 2495 2.69 / 7.25 2 3
3 13 25.16 18 15.53 338 94 2.78 / 7.34 2 3
4 8 0.04 165 15.50 292 747 3.53 / 8.09 2 6
Average= 2.70
(KJ/cycle)

Cycle 1 GMT 26/12/2019 14:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.08 23 15.60 427 153 0.15 / 1.78 3 3
2 10 1026.20 3 15.47 1837 85 0.24 / 1.86 2 2
3 7 1006.88 74 15.33 1721 1952 2.19 / 3.81 2 3
4 8 0.00 165 15.52 293 750 2.94 / 4.56 2 7
Average= 2.28
(KJ/cycle)

Cycle 0 GMT 26/12/2019 4:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 140.12 22 15.72 463 160 0.16 / 0.16 3 3
2 7 154.48 75 15.69 473 557 0.72 / 0.72 3 3
3 8 0.24 240 15.66 241 906 1.62 / 1.62 3 13
Average= 1.62
(KJ/cycle)