SIO Argo Site:
Pump Diagnostics Page   



Serial= 8817 WMO= 3902171

Return

←PreviousNext→

Cycle 186 GMT 23/11/2024 13:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 30 14.77 442 196 0.20 / 728.22 2 3
2 7 2009.24 53 14.74 3071 2399 2.59 / 730.62 2 2
3 13 995.36 20 14.66 1705 500 3.09 / 731.12 2 4
4 13 257.16 20 14.82 661 196 3.29 / 731.32 2 3
5 8 0.24 165 14.82 262 641 3.93 / 731.96 2 6
Average= 3.91
(KJ/cycle)

Cycle 185 GMT 13/11/2024 18:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.36 30 14.77 449 199 0.20 / 724.30 2 3
2 7 2005.80 53 14.72 3070 2395 2.59 / 726.69 2 2
3 13 996.76 20 14.67 1710 502 3.10 / 727.20 2 3
4 13 241.44 20 14.81 639 189 3.29 / 727.39 2 3
5 8 0.12 165 14.83 262 641 3.93 / 728.03 2 3
Average= 3.91
(KJ/cycle)

Cycle 184 GMT 3/11/2024 23:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.56 30 14.78 439 195 0.19 / 720.40 2 3
2 7 2011.56 52 14.73 3081 2360 2.55 / 722.76 2 2
3 13 999.32 20 14.68 1720 505 3.06 / 723.26 2 3
4 13 249.72 20 14.81 653 193 3.25 / 723.46 2 3
5 8 -0.04 165 14.83 263 644 3.90 / 724.10 2 3
Average= 3.91
(KJ/cycle)

Cycle 183 GMT 25/10/2024 4:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 30 14.77 417 185 0.18 / 716.51 2 3
2 7 2012.00 52 14.73 3072 2353 2.54 / 718.86 2 2
3 13 1006.00 20 14.68 1731 508 3.05 / 719.37 2 4
4 13 245.96 20 14.82 646 191 3.24 / 719.56 2 4
5 8 0.16 165 14.84 264 646 3.88 / 720.20 2 5
Average= 3.91
(KJ/cycle)

Cycle 182 GMT 15/10/2024 9:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 30 14.77 439 195 0.19 / 712.51 2 3
2 7 2008.08 52 14.74 3070 2353 2.55 / 714.86 2 2
3 13 994.60 20 14.69 1707 502 3.05 / 715.36 2 4
4 13 254.92 20 14.82 662 196 3.25 / 715.56 2 3
5 8 0.24 165 14.85 263 644 3.89 / 716.20 2 8
6 14 0.24 30 14.82 264 117 4.01 / 716.32 3 6
Average= 3.91
(KJ/cycle)

Cycle 181 GMT 5/10/2024 15: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 30 14.78 441 196 0.20 / 708.50 2 3
2 7 2004.16 52 14.74 3070 2353 2.55 / 710.85 2 2
3 13 1003.80 20 14.68 1720 505 3.05 / 711.36 2 3
4 13 257.40 20 14.81 661 196 3.25 / 711.55 2 3
5 8 0.08 165 14.84 263 644 3.89 / 712.20 2 5
6 14 0.08 30 14.82 264 117 4.01 / 712.31 2 5
Average= 3.91
(KJ/cycle)

Cycle 180 GMT 25/ 9/2024 20:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 30 14.78 432 192 0.19 / 704.56 2 3
2 7 2004.68 53 14.75 3073 2402 2.59 / 706.96 2 2
3 13 995.52 20 14.66 1711 502 3.10 / 707.46 2 3
4 13 250.72 20 14.82 655 194 3.29 / 707.66 2 3
5 8 0.00 165 14.83 264 646 3.94 / 708.30 2 7
Average= 3.91
(KJ/cycle)

Cycle 179 GMT 16/ 9/2024 1:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 30 14.78 438 194 0.19 / 700.62 2 3
2 7 2010.04 53 14.73 3083 2407 2.60 / 703.03 2 2
3 13 993.08 20 14.68 1700 499 3.10 / 703.53 2 4
4 13 258.52 20 14.83 665 197 3.30 / 703.73 2 3
5 8 0.00 165 14.84 261 639 3.94 / 704.37 2 6
Average= 3.91
(KJ/cycle)

Cycle 178 GMT 6/ 9/2024 6:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 30 14.79 438 194 0.19 / 696.69 2 3
2 7 2003.64 53 14.74 3076 2403 2.60 / 699.09 2 2
3 13 988.56 20 14.69 1703 500 3.10 / 699.59 2 4
4 13 244.40 20 14.80 643 190 3.29 / 699.78 2 4
5 8 0.24 165 14.84 264 646 3.93 / 700.43 2 5
Average= 3.91
(KJ/cycle)

Cycle 177 GMT 27/ 8/2024 12: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 30 14.79 437 194 0.19 / 692.76 2 3
2 7 2006.64 53 14.76 3069 2401 2.59 / 695.16 2 2
3 13 985.08 20 14.70 1706 502 3.10 / 695.66 2 4
4 13 243.80 20 14.85 648 192 3.29 / 695.86 2 3
5 8 -0.04 165 14.84 261 639 3.93 / 696.50 2 3
Average= 3.91
(KJ/cycle)

Cycle 176 GMT 17/ 8/2024 17:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 30 14.78 439 195 0.19 / 688.73 2 3
2 7 2002.88 53 14.74 3066 2395 2.59 / 691.12 2 2
3 13 997.16 20 14.68 1705 501 3.09 / 691.62 2 4
4 13 250.48 20 14.84 651 193 3.28 / 691.82 2 3
5 8 0.04 165 14.85 260 637 3.92 / 692.45 2 5
6 14 0.04 30 14.82 260 116 4.04 / 692.57 2 6
Average= 3.91
(KJ/cycle)

Cycle 175 GMT 7/ 8/2024 22:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 30 14.78 427 189 0.19 / 684.78 2 3
2 7 2011.12 53 14.73 3074 2400 2.59 / 687.18 2 2
3 13 1009.80 20 14.68 1729 508 3.10 / 687.69 2 3
4 13 261.04 20 14.82 671 199 3.30 / 687.89 2 3
5 8 0.20 165 14.84 263 644 3.94 / 688.53 2 5
Average= 3.91
(KJ/cycle)

Cycle 174 GMT 29/ 7/2024 3:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.52 30 14.77 441 195 0.20 / 680.72 2 3
2 7 2009.16 53 14.75 3075 2404 2.60 / 683.13 2 2
3 13 1003.92 20 14.69 1724 507 3.11 / 683.63 2 4
4 13 269.08 20 14.82 683 202 3.31 / 683.84 2 3
5 8 -0.12 165 14.85 261 640 3.95 / 684.48 2 4
6 14 -0.12 30 14.81 261 116 4.06 / 684.59 2 5
Average= 3.91
(KJ/cycle)

Cycle 173 GMT 19/ 7/2024 8:33:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 30 14.79 417 185 0.19 / 676.82 2 2
2 7 2010.88 52 14.75 3092 2372 2.56 / 679.19 2 2
3 13 1004.88 20 14.69 1727 507 3.06 / 679.70 2 3
4 13 243.48 20 14.82 642 190 3.25 / 679.89 2 3
5 8 0.00 165 14.85 262 642 3.90 / 680.53 2 5
Average= 3.91
(KJ/cycle)

Cycle 172 GMT 9/ 7/2024 13:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 30 14.79 412 183 0.18 / 672.91 2 3
2 7 2003.00 53 14.74 3076 2403 2.59 / 675.31 2 2
3 13 896.56 20 14.71 1576 464 3.05 / 675.77 2 3
4 13 296.76 20 14.81 720 213 3.26 / 675.99 2 4
5 8 0.12 165 14.84 263 644 3.91 / 676.63 2 3
Average= 3.91
(KJ/cycle)

Cycle 171 GMT 29/ 6/2024 18: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.28 30 14.78 434 192 0.19 / 668.89 2 3
2 7 2008.80 53 14.75 3065 2396 2.59 / 671.28 2 2
3 13 988.60 20 14.70 1698 499 3.09 / 671.78 2 3
4 13 250.40 20 14.82 651 193 3.28 / 671.98 2 3
5 8 0.12 165 14.84 259 634 3.91 / 672.61 2 4
6 14 0.12 30 14.81 258 115 4.03 / 672.73 2 6
Average= 3.91
(KJ/cycle)

Cycle 170 GMT 19/ 6/2024 23:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 30 14.77 423 187 0.19 / 664.98 2 3
2 7 2003.32 53 14.75 3058 2391 2.58 / 667.37 2 2
3 13 995.84 20 14.70 1705 501 3.08 / 667.87 2 4
4 13 259.68 20 14.84 665 197 3.28 / 668.07 2 3
5 8 0.04 165 14.84 257 629 3.91 / 668.70 2 8
Average= 3.91
(KJ/cycle)

Cycle 169 GMT 10/ 6/2024 4:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 30 14.78 429 190 0.19 / 661.06 2 3
2 7 2011.20 53 14.74 3077 2404 2.59 / 663.46 2 2
3 13 995.00 20 14.69 1712 503 3.10 / 663.97 2 3
4 13 246.04 20 14.82 641 190 3.29 / 664.16 2 4
5 8 0.16 165 14.84 259 634 3.92 / 664.79 2 7
Average= 3.91
(KJ/cycle)

Cycle 168 GMT 31/ 5/2024 9:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.32 30 14.80 433 192 0.19 / 657.06 2 3
2 7 2004.76 53 14.75 3060 2392 2.58 / 659.45 2 2
3 13 1001.88 20 14.71 1716 505 3.09 / 659.95 2 4
4 13 251.36 20 14.84 654 194 3.28 / 660.15 2 3
5 13 22.72 20 14.87 299 89 3.37 / 660.24 2 3
6 8 0.04 165 14.84 258 632 4.00 / 660.87 2 4
Average= 3.91
(KJ/cycle)

Cycle 167 GMT 21/ 5/2024 14:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.92 30 14.78 433 192 0.19 / 653.14 2 3
2 7 2003.08 53 14.76 3056 2391 2.58 / 655.53 2 2
3 13 996.84 20 14.72 1710 503 3.09 / 656.04 2 3
4 13 246.64 20 14.84 648 192 3.28 / 656.23 2 3
5 8 0.12 165 14.85 259 635 3.91 / 656.86 2 3
Average= 3.91
(KJ/cycle)

Cycle 166 GMT 11/ 5/2024 20: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 30 14.79 412 183 0.18 / 649.21 2 3
2 7 2007.16 53 14.76 3080 2409 2.59 / 651.62 2 2
3 13 995.32 20 14.71 1707 502 3.09 / 652.12 2 3
4 13 247.96 20 14.84 647 192 3.29 / 652.31 2 4
5 8 -0.16 165 14.84 261 639 3.93 / 652.95 2 5
Average= 3.91
(KJ/cycle)

Cycle 165 GMT 2/ 5/2024 0:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.12 30 14.79 436 193 0.19 / 645.30 2 3
2 7 2009.04 53 14.73 3067 2394 2.59 / 647.69 2 2
3 13 1002.24 20 14.71 1727 508 3.10 / 648.20 2 3
4 13 250.12 20 14.84 649 193 3.29 / 648.39 2 3
5 8 -0.08 165 14.85 259 635 3.92 / 649.03 2 5
Average= 3.91
(KJ/cycle)

Cycle 164 GMT 22/ 4/2024 6: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.52 30 14.80 433 192 0.19 / 641.39 2 3
2 7 2002.84 53 14.76 3055 2390 2.58 / 643.78 2 2
3 13 998.64 20 14.69 1709 502 3.08 / 644.28 2 4
4 13 246.76 20 14.85 642 191 3.27 / 644.47 2 4
5 8 0.36 165 14.85 259 635 3.91 / 645.10 2 6
Average= 3.91
(KJ/cycle)

Cycle 163 GMT 12/ 4/2024 11:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.48 30 14.80 433 192 0.19 / 637.39 2 3
2 7 2003.04 53 14.76 3063 2396 2.59 / 639.79 2 2
3 13 994.44 20 14.71 1707 502 3.09 / 640.29 2 3
4 13 237.40 20 14.85 629 187 3.28 / 640.48 2 3
5 13 19.28 20 14.89 294 88 3.36 / 640.56 2 3
6 8 -0.28 165 14.86 257 630 4.00 / 641.19 2 7
Average= 3.91
(KJ/cycle)

Cycle 162 GMT 2/ 4/2024 16:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 30 14.79 410 182 0.18 / 633.37 2 3
2 7 2007.56 53 14.76 3068 2400 2.58 / 635.77 2 2
3 13 999.20 20 14.70 1714 504 3.09 / 636.28 2 4
4 13 258.76 20 14.84 662 196 3.28 / 636.48 2 3
5 13 21.12 20 14.88 296 88 3.37 / 636.56 2 3
6 8 0.24 165 14.86 259 635 4.01 / 637.20 2 8
Average= 3.91
(KJ/cycle)

Cycle 161 GMT 23/ 3/2024 21:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.56 30 14.79 432 192 0.19 / 629.38 2 3
2 7 2008.76 53 14.74 3078 2405 2.60 / 631.78 2 2
3 13 989.20 20 14.71 1702 501 3.10 / 632.28 2 4
4 13 243.68 20 14.85 641 190 3.29 / 632.47 2 3
5 13 19.64 20 14.88 294 87 3.37 / 632.56 2 3
6 8 0.04 165 14.84 258 632 4.01 / 633.19 2 6
Average= 3.91
(KJ/cycle)

Cycle 160 GMT 14/ 3/2024 2:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.40 30 14.80 433 192 0.19 / 625.45 2 3
2 7 2009.52 53 14.76 3078 2408 2.60 / 627.86 2 2
3 13 996.64 20 14.70 1712 503 3.10 / 628.36 2 4
4 13 238.72 20 14.83 631 187 3.29 / 628.55 2 3
5 8 -0.04 165 14.85 260 637 3.93 / 629.19 2 5
Average= 3.91
(KJ/cycle)

Cycle 159 GMT 4/ 3/2024 7:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 30 14.78 411 182 0.18 / 621.42 2 3
2 7 2011.60 53 14.76 3080 2409 2.59 / 623.83 2 2
3 13 1004.28 20 14.71 1720 506 3.10 / 624.33 2 4
4 13 260.20 20 14.85 665 198 3.30 / 624.53 2 3
5 13 19.76 20 14.89 297 88 3.38 / 624.62 2 3
6 8 0.00 165 14.86 261 640 4.02 / 625.26 2 5
Average= 3.91
(KJ/cycle)

Cycle 158 GMT 23/ 2/2024 12:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.24 30 14.78 442 196 0.20 / 617.39 2 3
2 7 2008.40 53 14.76 3082 2411 2.61 / 619.80 2 2
3 13 1009.32 20 14.72 1732 510 3.12 / 620.31 2 4
4 13 256.32 20 14.86 659 196 3.31 / 620.51 2 3
5 13 20.44 20 14.89 297 88 3.40 / 620.60 2 3
6 8 -0.04 165 14.85 260 637 4.04 / 621.23 2 5
Average= 3.91
(KJ/cycle)

Cycle 157 GMT 13/ 2/2024 18: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.96 30 14.79 423 188 0.19 / 613.37 2 3
2 7 2010.56 53 14.77 3071 2404 2.59 / 615.78 2 2
3 13 997.92 20 14.71 1714 504 3.10 / 616.28 2 4
4 13 245.76 20 14.86 645 192 3.29 / 616.47 2 3
5 13 17.60 20 14.89 294 88 3.38 / 616.56 2 3
6 8 0.20 165 14.86 260 637 4.01 / 617.20 2 5
Average= 3.91
(KJ/cycle)

Cycle 156 GMT 3/ 2/2024 23:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.96 30 14.79 429 190 0.19 / 609.41 2 3
2 7 2009.16 52 14.76 3072 2358 2.55 / 611.77 2 2
3 13 997.04 20 14.72 1705 502 3.05 / 612.27 2 4
4 13 247.84 20 14.83 645 191 3.24 / 612.46 2 4
5 13 20.88 20 14.88 295 88 3.33 / 612.55 2 3
6 8 -0.12 165 14.85 259 635 3.96 / 613.18 3 5
Average= 3.91
(KJ/cycle)

Cycle 155 GMT 25/ 1/2024 1:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 30 14.81 418 186 0.19 / 605.28 2 3
2 7 2010.96 53 14.76 3076 2406 2.59 / 607.68 2 2
3 13 1007.68 20 14.71 1727 508 3.10 / 608.19 2 4
4 13 252.72 20 14.84 651 193 3.29 / 608.38 2 3
5 13 23.68 20 14.89 301 90 3.38 / 608.47 2 3
6 8 -0.04 165 14.85 258 632 4.02 / 609.11 2 7
7 14 -0.04 30 14.83 257 114 4.13 / 609.22 3 6
Average= 3.91
(KJ/cycle)

Cycle 154 GMT 15/ 1/2024 4:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.20 30 14.80 427 190 0.19 / 601.23 2 3
2 7 2004.80 53 14.78 3079 2412 2.60 / 603.65 2 2
3 13 999.44 20 14.71 1714 504 3.11 / 604.15 2 4
4 13 255.88 20 14.84 655 194 3.30 / 604.35 2 3
5 8 0.08 165 14.86 258 633 3.93 / 604.98 2 6
6 14 0.08 30 14.85 254 113 4.05 / 605.09 2 7
Average= 3.90
(KJ/cycle)

Cycle 153 GMT 5/ 1/2024 6:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 30 14.81 426 189 0.19 / 597.31 2 3
2 7 2013.16 53 14.76 3081 2410 2.60 / 599.72 2 2
3 13 989.40 20 14.71 1698 500 3.10 / 600.22 2 4
4 13 244.64 20 14.85 639 190 3.29 / 600.41 2 3
5 8 0.12 165 14.87 259 635 3.92 / 601.04 2 6
Average= 3.90
(KJ/cycle)

Cycle 152 GMT 26/12/2023 9:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.92 30 14.82 437 194 0.19 / 593.37 2 3
2 7 2004.32 53 14.78 3073 2407 2.60 / 595.77 2 2
3 13 1017.24 20 14.71 1738 511 3.11 / 596.29 2 3
4 13 267.96 20 14.87 678 202 3.31 / 596.49 2 3
5 8 0.12 165 14.87 258 633 3.95 / 597.12 2 5
Average= 3.90
(KJ/cycle)

Cycle 151 GMT 16/12/2023 11:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 30 14.81 423 188 0.19 / 589.47 2 3
2 7 2009.16 52 14.77 3083 2368 2.56 / 591.84 2 2
3 13 990.64 20 14.72 1711 504 3.06 / 592.34 2 3
4 13 251.72 20 14.85 653 194 3.25 / 592.54 2 3
5 8 0.08 165 14.87 260 638 3.89 / 593.17 2 6
Average= 3.90
(KJ/cycle)

Cycle 150 GMT 6/12/2023 14:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 30 14.81 433 192 0.19 / 585.54 2 3
2 7 2010.20 53 14.75 3083 2410 2.60 / 587.95 2 2
3 13 995.80 20 14.72 1715 505 3.11 / 588.45 2 3
4 13 241.84 20 14.86 638 190 3.30 / 588.64 2 3
5 8 0.00 165 14.88 260 638 3.94 / 589.28 2 5
Average= 3.90
(KJ/cycle)

Cycle 149 GMT 26/11/2023 17: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.36 30 14.82 429 191 0.19 / 581.59 2 3
2 7 2006.36 53 14.77 3080 2411 2.60 / 584.01 2 2
3 13 1001.92 20 14.74 1722 508 3.11 / 584.51 2 3
4 13 248.92 20 14.86 649 193 3.30 / 584.71 2 4
5 8 0.04 165 14.88 261 641 3.94 / 585.35 2 6
Average= 3.90
(KJ/cycle)

Cycle 148 GMT 16/11/2023 19:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.12 30 14.81 433 192 0.19 / 577.68 2 3
2 7 2008.24 53 14.77 3078 2409 2.60 / 580.09 2 2
3 13 891.88 20 14.73 1568 462 3.06 / 580.55 2 4
4 13 293.68 20 14.85 718 213 3.28 / 580.76 2 3
5 8 0.12 165 14.87 262 643 3.92 / 581.40 2 7
Average= 3.90
(KJ/cycle)

Cycle 147 GMT 6/11/2023 21:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.64 30 14.83 435 194 0.19 / 573.80 2 3
2 7 2003.92 52 14.77 3071 2359 2.55 / 576.16 2 2
3 13 897.20 20 14.76 1578 466 3.02 / 576.63 2 4
4 13 303.44 20 14.85 731 217 3.24 / 576.84 2 3
5 8 0.04 165 14.87 261 640 3.88 / 577.48 2 5
Average= 3.90
(KJ/cycle)

Cycle 146 GMT 28/10/2023 0:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.20 30 14.83 434 193 0.19 / 569.87 2 3
2 7 2004.36 53 14.77 3074 2406 2.60 / 572.28 2 2
3 13 988.24 20 14.71 1700 500 3.10 / 572.78 2 4
4 13 249.16 20 14.87 648 193 3.29 / 572.97 2 3
5 8 0.08 165 14.87 260 638 3.93 / 573.61 2 5
Average= 3.90
(KJ/cycle)

Cycle 145 GMT 18/10/2023 3: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.68 30 14.83 435 194 0.19 / 565.94 2 3
2 7 2008.60 53 14.77 3067 2401 2.59 / 568.34 2 2
3 13 997.20 20 14.72 1716 505 3.10 / 568.84 2 4
4 13 249.32 20 14.87 652 194 3.29 / 569.04 2 4
5 8 0.12 165 14.89 260 639 3.93 / 569.68 2 6
Average= 3.90
(KJ/cycle)

Cycle 144 GMT 8/10/2023 5:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 30 14.83 433 193 0.19 / 562.12 2 3
2 7 2010.44 52 14.77 3079 2365 2.56 / 564.48 2 2
3 13 889.48 20 14.77 1568 463 3.02 / 564.95 2 4
4 13 184.92 20 14.89 547 163 3.18 / 565.11 2 3
5 8 -0.08 165 14.88 259 636 3.82 / 565.75 2 5
Average= 3.90
(KJ/cycle)

Cycle 143 GMT 28/ 9/2023 7:51:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 30 14.83 419 186 0.19 / 558.22 2 3
2 7 2002.52 53 14.76 3057 2391 2.58 / 560.62 2 2
3 13 883.08 20 14.76 1559 460 3.04 / 561.08 2 3
4 13 287.12 20 14.88 708 211 3.25 / 561.29 2 4
5 8 0.04 165 14.89 260 639 3.89 / 561.93 2 5
Average= 3.90
(KJ/cycle)

Cycle 142 GMT 18/ 9/2023 10:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 30 14.84 409 182 0.18 / 554.31 2 3
2 7 2010.44 53 14.78 3080 2413 2.59 / 556.72 2 2
3 13 893.84 20 14.76 1576 465 3.06 / 557.19 2 3
4 13 297.96 20 14.86 727 216 3.28 / 557.40 2 3
5 8 0.16 165 14.89 259 636 3.91 / 558.04 2 4
Average= 3.90
(KJ/cycle)

Cycle 141 GMT 8/ 9/2023 12:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 30 14.84 433 193 0.19 / 550.28 2 3
2 7 2005.56 53 14.77 3074 2406 2.60 / 552.68 2 2
3 13 997.24 20 14.73 1715 505 3.10 / 553.19 2 3
4 13 250.64 20 14.87 647 192 3.30 / 553.38 2 3
5 8 0.12 165 14.89 257 631 3.93 / 554.01 2 5
6 14 0.12 30 14.86 258 115 4.04 / 554.13 3 6
Average= 3.90
(KJ/cycle)

Cycle 140 GMT 29/ 8/2023 15: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 30 14.83 420 187 0.19 / 546.34 2 3
2 7 2003.72 53 14.77 3065 2399 2.59 / 548.74 2 2
3 13 1006.00 20 14.73 1728 509 3.10 / 549.25 2 3
4 13 258.76 20 14.87 660 196 3.29 / 549.45 2 4
5 8 -0.04 165 14.89 259 636 3.93 / 550.08 2 9
Average= 3.90
(KJ/cycle)

Cycle 139 GMT 19/ 8/2023 17:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 30 14.84 421 187 0.19 / 542.39 2 3
2 7 2008.08 53 14.78 3078 2411 2.60 / 544.80 2 2
3 13 1012.12 20 14.74 1733 511 3.11 / 545.32 2 4
4 13 270.24 20 14.87 683 203 3.31 / 545.52 2 4
5 8 0.28 165 14.89 259 636 3.95 / 546.15 2 8
Average= 3.90
(KJ/cycle)

Cycle 138 GMT 9/ 8/2023 20: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 30 14.83 417 186 0.19 / 538.40 2 3
2 7 2010.68 52 14.79 3088 2375 2.56 / 540.77 2 2
3 13 895.12 20 14.75 1574 464 3.02 / 541.24 2 3
4 13 296.96 20 14.87 723 215 3.24 / 541.45 2 3
5 8 -0.24 165 14.89 259 636 3.88 / 542.09 2 5
6 14 -0.24 30 14.86 259 115 3.99 / 542.21 5 6
Average= 3.90
(KJ/cycle)

Cycle 137 GMT 30/ 7/2023 22:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 30 14.83 427 190 0.19 / 534.47 2 3
2 7 2005.88 53 14.77 3066 2400 2.59 / 536.87 2 2
3 13 1011.24 20 14.74 1733 511 3.10 / 537.38 2 3
4 13 257.40 20 14.87 660 196 3.30 / 537.58 2 4
5 8 0.32 165 14.89 260 639 3.94 / 538.21 2 6
Average= 3.90
(KJ/cycle)

Cycle 136 GMT 21/ 7/2023 0:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.52 30 14.83 436 194 0.19 / 530.54 2 3
2 7 2011.28 53 14.78 3078 2411 2.61 / 532.95 2 2
3 13 1000.08 20 14.74 1712 505 3.11 / 533.46 2 3
4 13 244.56 20 14.88 641 191 3.30 / 533.65 2 3
5 8 -0.08 165 14.90 257 632 3.93 / 534.28 2 8
Average= 3.90
(KJ/cycle)

Cycle 135 GMT 11/ 7/2023 3:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 30 14.84 420 187 0.19 / 526.48 2 3
2 7 2009.44 53 14.78 3071 2406 2.59 / 528.89 2 2
3 13 1000.28 20 14.75 1720 507 3.10 / 529.40 2 4
4 13 262.68 20 14.87 669 199 3.30 / 529.60 2 4
5 8 0.04 165 14.89 258 634 3.93 / 530.23 2 6
6 14 0.04 30 14.87 259 116 4.05 / 530.35 2 8
Average= 3.90
(KJ/cycle)

Cycle 134 GMT 1/ 7/2023 5:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 30 14.83 433 193 0.19 / 522.57 2 3
2 7 2005.32 53 14.79 3070 2406 2.60 / 524.98 2 2
3 13 983.96 20 14.73 1690 498 3.10 / 525.47 2 3
4 13 233.52 20 14.88 626 186 3.28 / 525.66 2 3
5 8 0.28 165 14.90 259 637 3.92 / 526.30 2 7
Average= 3.90
(KJ/cycle)

Cycle 133 GMT 21/ 6/2023 8:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 30 14.84 412 183 0.18 / 518.59 3 3
2 7 2011.20 53 14.77 3075 2407 2.59 / 521.00 2 2
3 13 990.68 20 14.74 1708 504 3.09 / 521.50 2 4
4 13 342.64 20 14.85 789 234 3.33 / 521.74 2 4
5 8 0.00 165 14.89 260 639 3.97 / 522.38 2 5
Average= 3.90
(KJ/cycle)

Cycle 132 GMT 11/ 6/2023 11: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 30 14.84 410 183 0.18 / 514.68 2 3
2 7 2006.96 53 14.79 3075 2410 2.59 / 517.09 2 2
3 13 979.32 20 14.76 1690 499 3.09 / 517.59 2 4
4 13 227.84 20 14.91 618 184 3.28 / 517.77 2 3
5 8 -0.04 165 14.91 259 637 3.91 / 518.41 3 4
Average= 3.90
(KJ/cycle)

Cycle 131 GMT 1/ 6/2023 13:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.96 30 14.83 432 192 0.19 / 510.73 2 3
2 7 2012.16 53 14.80 3092 2425 2.62 / 513.16 2 2
3 13 1007.72 20 14.75 1727 509 3.13 / 513.67 2 4
4 13 249.72 20 14.90 653 195 3.32 / 513.86 2 3
5 8 0.12 165 14.90 259 637 3.96 / 514.50 2 4
Average= 3.90
(KJ/cycle)

Cycle 130 GMT 22/ 5/2023 16: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 30 14.83 411 183 0.18 / 506.66 2 3
2 7 2009.72 53 14.79 3095 2426 2.61 / 509.09 2 2
3 13 996.92 20 14.73 1711 504 3.11 / 509.59 2 3
4 13 249.20 20 14.89 650 194 3.31 / 509.79 2 3
5 8 0.00 165 14.90 259 637 3.94 / 510.42 2 4
6 14 0.00 30 14.87 258 115 4.06 / 510.54 2 5
Average= 3.90
(KJ/cycle)

Cycle 129 GMT 12/ 5/2023 18:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 30 14.83 405 180 0.18 / 502.73 2 3
2 7 2004.32 53 14.78 3069 2404 2.58 / 505.13 2 2
3 13 1015.80 20 14.74 1740 513 3.10 / 505.64 2 4
4 13 262.40 20 14.88 669 199 3.30 / 505.84 2 3
5 8 0.00 165 14.89 259 636 3.93 / 506.48 2 4
Average= 3.90
(KJ/cycle)

Cycle 128 GMT 2/ 5/2023 21: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 30 14.82 428 190 0.19 / 498.88 2 3
2 7 2007.96 53 14.78 3076 2410 2.60 / 501.29 2 2
3 13 884.16 20 14.76 1558 460 3.06 / 501.75 2 3
4 13 191.76 20 14.89 562 167 3.23 / 501.91 2 3
5 8 0.04 165 14.89 258 634 3.86 / 502.55 2 5
Average= 3.90
(KJ/cycle)

Cycle 127 GMT 22/ 4/2023 23:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 30 14.84 431 192 0.19 / 494.95 2 3
2 7 2006.92 53 14.77 3070 2403 2.60 / 497.35 2 2
3 13 1004.56 20 14.73 1725 508 3.10 / 497.86 2 3
4 13 248.40 20 14.89 646 192 3.30 / 498.05 2 3
5 8 0.00 165 14.90 259 637 3.93 / 498.69 2 5
Average= 3.90
(KJ/cycle)

Cycle 126 GMT 13/ 4/2023 1:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 30 14.85 428 191 0.19 / 491.02 2 3
2 7 2002.60 53 14.79 3062 2400 2.59 / 493.42 2 2
3 13 992.12 20 14.76 1707 504 3.09 / 493.93 2 4
4 13 240.28 20 14.91 636 190 3.28 / 494.12 2 4
5 8 0.36 165 14.91 259 637 3.92 / 494.75 2 7
Average= 3.90
(KJ/cycle)

Cycle 125 GMT 3/ 4/2023 4:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.56 30 14.83 428 190 0.19 / 486.98 2 3
2 7 2007.80 53 14.79 3071 2407 2.60 / 489.39 2 2
3 13 995.24 20 14.76 1711 505 3.10 / 489.90 2 3
4 13 236.32 20 14.89 628 187 3.29 / 490.08 2 3
5 8 0.00 165 14.90 258 634 3.92 / 490.72 2 4
6 14 0.00 30 14.87 256 114 4.04 / 490.83 2 8
Average= 3.90
(KJ/cycle)

Cycle 124 GMT 24/ 3/2023 6:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.64 30 14.84 434 193 0.19 / 482.99 2 3
2 7 2005.28 53 14.78 3068 2403 2.60 / 485.39 2 2
3 13 996.84 20 14.73 1709 503 3.10 / 485.89 2 4
4 13 224.36 20 14.92 608 181 3.28 / 486.07 2 3
5 13 18.32 20 14.93 290 87 3.37 / 486.16 2 3
6 8 0.00 165 14.90 258 634 4.00 / 486.79 2 6
Average= 3.89
(KJ/cycle)

Cycle 123 GMT 14/ 3/2023 9:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 30 14.84 405 180 0.18 / 478.98 2 3
2 7 2002.68 53 14.79 3069 2406 2.59 / 481.39 2 2
3 13 974.48 20 14.76 1686 498 3.08 / 481.89 2 4
4 13 223.80 20 14.92 611 182 3.27 / 482.07 2 3
5 13 20.32 20 14.94 294 88 3.35 / 482.16 2 3
6 8 0.16 165 14.90 259 637 3.99 / 482.79 2 5
Average= 3.89
(KJ/cycle)

Cycle 122 GMT 4/ 3/2023 12: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.88 30 14.84 430 191 0.19 / 474.97 2 3
2 7 2009.72 53 14.80 3078 2414 2.61 / 477.38 2 2
3 13 986.64 20 14.76 1702 502 3.11 / 477.89 2 4
4 13 237.84 20 14.91 633 189 3.30 / 478.08 2 4
5 13 19.56 20 14.94 295 88 3.39 / 478.16 2 3
6 8 0.00 165 14.91 259 637 4.02 / 478.80 2 8
Average= 3.89
(KJ/cycle)

Cycle 121 GMT 22/ 2/2023 14:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.12 30 14.83 433 193 0.19 / 470.96 3 3
2 7 2006.28 53 14.79 3067 2404 2.60 / 473.37 2 2
3 13 982.36 20 14.76 1695 500 3.10 / 473.87 2 3
4 13 228.92 20 14.91 618 184 3.28 / 474.05 2 3
5 13 18.56 20 14.95 294 88 3.37 / 474.14 2 3
6 8 -0.12 165 14.91 260 640 4.01 / 474.78 2 4
Average= 3.89
(KJ/cycle)

Cycle 120 GMT 12/ 2/2023 17: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.08 30 14.84 433 193 0.19 / 466.96 2 3
2 7 2007.24 53 14.80 3067 2406 2.60 / 469.36 2 2
3 13 886.44 20 14.80 1563 463 3.06 / 469.83 2 3
4 13 287.76 20 14.89 707 211 3.27 / 470.04 2 4
5 13 23.72 20 14.94 301 90 3.36 / 470.13 2 3
6 8 0.12 165 14.91 261 642 4.00 / 470.77 2 6
Average= 3.89
(KJ/cycle)

Cycle 119 GMT 2/ 2/2023 19:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.12 30 14.84 428 191 0.19 / 462.98 2 3
2 7 2012.00 52 14.81 3073 2367 2.56 / 465.35 2 2
3 13 992.28 20 14.76 1706 504 3.06 / 465.85 2 3
4 13 238.80 20 14.89 634 189 3.25 / 466.04 2 4
5 13 20.72 20 14.92 297 89 3.34 / 466.13 2 3
6 8 -0.08 165 14.90 259 637 3.97 / 466.77 2 5
Average= 3.89
(KJ/cycle)

Cycle 118 GMT 23/ 1/2023 22: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 30 14.85 405 180 0.18 / 458.89 2 3
2 7 2005.80 52 14.79 3063 2356 2.54 / 461.25 2 2
3 13 1001.28 20 14.77 1722 509 3.04 / 461.76 2 3
4 13 238.00 20 14.92 634 189 3.23 / 461.95 2 3
5 13 19.68 20 14.95 296 89 3.32 / 462.04 2 3
6 8 0.00 165 14.91 260 640 3.96 / 462.68 2 5
7 14 0.00 30 14.87 258 115 4.08 / 462.79 2 7
Average= 3.89
(KJ/cycle)

Cycle 117 GMT 14/ 1/2023 0:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 30 14.85 431 192 0.19 / 454.91 2 3
2 7 2010.08 53 14.80 3078 2414 2.61 / 457.32 2 2
3 13 880.24 20 14.79 1548 458 3.06 / 457.78 2 4
4 13 280.48 20 14.89 698 208 3.27 / 457.99 2 4
5 13 21.24 20 14.93 299 89 3.36 / 458.08 2 3
6 8 0.08 165 14.90 258 634 4.00 / 458.71 2 9
Average= 3.89
(KJ/cycle)

Cycle 116 GMT 4/ 1/2023 3: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.68 30 14.86 438 195 0.20 / 450.97 2 3
2 7 2003.36 53 14.79 3073 2409 2.60 / 453.38 2 2
3 13 993.72 20 14.77 1708 505 3.11 / 453.89 2 3
4 13 245.32 20 14.92 646 193 3.30 / 454.08 2 3
5 8 0.00 165 14.92 260 640 3.94 / 454.72 2 6
Average= 3.89
(KJ/cycle)

Cycle 115 GMT 25/12/2022 5:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.00 30 14.86 439 196 0.20 / 447.06 2 3
2 7 2010.32 52 14.80 3073 2365 2.56 / 449.43 2 3
3 13 1002.56 20 14.76 1723 509 3.07 / 449.94 2 4
4 13 247.96 20 14.92 649 194 3.26 / 450.13 2 3
5 8 0.24 165 14.92 262 645 3.91 / 450.78 2 3
Average= 3.89
(KJ/cycle)

Cycle 114 GMT 15/12/2022 8:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 30 14.85 414 184 0.18 / 443.12 2 3
2 7 2005.20 53 14.80 3066 2405 2.59 / 445.53 2 2
3 13 994.80 20 14.78 1714 507 3.10 / 446.03 2 3
4 13 247.32 20 14.93 645 193 3.29 / 446.23 2 3
5 8 0.12 165 14.92 261 643 3.93 / 446.87 2 5
Average= 3.89
(KJ/cycle)

Cycle 113 GMT 5/12/2022 10:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 30 14.86 411 183 0.18 / 439.06 2 3
2 7 2003.72 53 14.82 3076 2416 2.60 / 441.48 2 2
3 13 996.60 20 14.78 1714 507 3.11 / 441.99 2 4
4 13 240.96 20 14.90 636 190 3.30 / 442.18 2 4
5 8 -0.08 165 14.93 262 645 3.94 / 442.82 2 4
6 14 -0.08 30 14.89 261 117 4.06 / 442.94 4 5
Average= 3.89
(KJ/cycle)

Cycle 112 GMT 25/11/2022 13:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.56 30 14.86 446 199 0.20 / 435.13 2 3
2 7 2007.76 53 14.81 3079 2417 2.62 / 437.54 2 2
3 13 990.04 20 14.77 1707 504 3.12 / 438.05 2 4
4 13 250.64 20 14.92 653 195 3.31 / 438.24 2 3
5 8 0.20 165 14.91 259 637 3.95 / 438.88 2 6
Average= 3.88
(KJ/cycle)

Cycle 111 GMT 15/11/2022 15:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.44 30 14.85 442 197 0.20 / 431.16 2 3
2 7 2006.72 53 14.80 3082 2418 2.61 / 433.58 2 2
3 13 1004.52 20 14.77 1725 510 3.12 / 434.09 2 3
4 13 255.48 20 14.92 662 198 3.32 / 434.29 2 4
5 8 0.08 165 14.92 261 643 3.96 / 434.93 2 7
Average= 3.88
(KJ/cycle)

Cycle 110 GMT 5/11/2022 18:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 30 14.85 439 196 0.20 / 427.15 2 3
2 7 2004.64 52 14.80 3072 2364 2.56 / 429.52 2 2
3 13 983.64 20 14.77 1693 500 3.06 / 430.02 2 4
4 13 245.52 20 14.90 645 192 3.25 / 430.21 2 4
5 8 -0.16 165 14.93 260 640 3.89 / 430.85 2 6
6 14 -0.16 30 14.91 260 116 4.01 / 430.96 2 7
Average= 3.88
(KJ/cycle)

Cycle 109 GMT 26/10/2022 20:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 30 14.87 439 196 0.20 / 423.20 2 3
2 7 2011.04 53 14.78 3089 2420 2.62 / 425.62 2 2
3 13 994.20 20 14.77 1715 507 3.12 / 426.12 2 4
4 13 238.92 20 14.92 633 189 3.31 / 426.31 2 4
5 8 0.36 165 14.92 261 643 3.95 / 426.96 2 3
Average= 3.88
(KJ/cycle)

Cycle 108 GMT 16/10/2022 23:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.44 30 14.88 439 196 0.20 / 419.31 2 3
2 7 2005.84 52 14.82 3093 2384 2.58 / 421.69 2 2
3 13 870.80 20 14.79 1541 456 3.04 / 422.15 2 4
4 13 276.40 20 14.91 691 206 3.24 / 422.35 2 4
5 8 -0.12 165 14.94 263 648 3.89 / 423.00 2 4
Average= 3.88
(KJ/cycle)

Cycle 107 GMT 7/10/2022 1:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.48 29 14.87 442 191 0.19 / 415.35 2 3
2 7 2006.20 53 14.83 3079 2420 2.61 / 417.77 2 2
3 13 1000.80 20 14.79 1727 511 3.12 / 418.28 2 4
4 13 242.40 20 14.90 642 191 3.31 / 418.47 2 4
5 8 0.20 165 14.93 261 643 3.96 / 419.11 2 6
Average= 3.88
(KJ/cycle)

Cycle 106 GMT 27/ 9/2022 4:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.04 29 14.85 442 190 0.19 / 411.29 2 3
2 7 2008.40 53 14.80 3092 2425 2.62 / 413.72 2 2
3 13 884.96 20 14.79 1565 463 3.08 / 414.18 2 4
4 13 289.12 20 14.89 714 213 3.29 / 414.39 2 4
5 8 0.00 165 14.93 263 648 3.94 / 415.04 2 4
6 14 0.00 30 14.91 261 117 4.06 / 415.16 2 6
Average= 3.88
(KJ/cycle)

Cycle 105 GMT 17/ 9/2022 6:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 29 14.86 424 183 0.18 / 407.40 2 3
2 7 2004.88 53 14.79 3072 2408 2.59 / 409.80 2 2
3 13 857.32 20 14.80 1523 451 3.04 / 410.25 2 4
4 13 257.24 20 14.91 663 198 3.24 / 410.45 2 3
5 8 0.20 165 14.93 263 648 3.89 / 411.10 2 5
Average= 3.88
(KJ/cycle)

Cycle 104 GMT 7/ 9/2022 9:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 29 14.86 435 187 0.19 / 403.48 2 3
2 7 2006.64 53 14.80 3080 2416 2.60 / 405.90 2 2
3 13 872.36 20 14.80 1543 457 3.06 / 406.36 2 4
4 13 274.56 20 14.91 690 206 3.27 / 406.56 2 4
5 8 0.24 165 14.93 264 650 3.92 / 407.21 2 5
Average= 3.88
(KJ/cycle)

Cycle 103 GMT 28/ 8/2022 11:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.32 30 14.85 445 198 0.20 / 399.45 2 3
2 7 2009.48 53 14.80 3083 2418 2.62 / 401.87 2 2
3 13 990.52 20 14.77 1709 505 3.12 / 402.37 2 3
4 13 247.60 20 14.92 648 193 3.31 / 402.57 2 4
5 13 21.92 20 14.95 298 89 3.40 / 402.65 2 3
6 8 -0.12 165 14.92 261 643 4.05 / 403.30 2 4
Average= 3.88
(KJ/cycle)

Cycle 102 GMT 18/ 8/2022 14: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 30 14.87 441 197 0.20 / 395.50 2 3
2 7 2008.16 53 14.80 3093 2426 2.62 / 397.92 2 2
3 13 975.76 20 14.77 1687 498 3.12 / 398.42 2 4
4 13 218.56 20 14.91 608 181 3.30 / 398.60 2 4
5 8 0.16 165 14.92 263 647 3.95 / 399.25 2 5
Average= 3.88
(KJ/cycle)

Cycle 101 GMT 8/ 8/2022 16:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.76 30 14.86 442 197 0.20 / 391.54 2 3
2 7 2006.28 53 14.81 3094 2429 2.63 / 393.97 2 2
3 13 987.12 20 14.78 1703 503 3.13 / 394.47 2 3
4 13 230.28 20 14.93 623 186 3.32 / 394.66 2 4
5 8 -0.04 165 14.93 261 643 3.96 / 395.30 2 3
Average= 3.88
(KJ/cycle)

Cycle 100 GMT 29/ 7/2022 19: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 30 14.87 419 187 0.19 / 387.58 2 3
2 7 2008.00 53 14.81 3084 2421 2.61 / 390.00 2 2
3 13 995.48 20 14.78 1713 506 3.11 / 390.50 2 4
4 13 247.44 20 14.92 649 194 3.31 / 390.70 2 4
5 8 0.36 165 14.93 262 645 3.95 / 391.34 2 5
Average= 3.87
(KJ/cycle)

Cycle 99 GMT 19/ 7/2022 21:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 30 14.86 422 188 0.19 / 383.63 2 3
2 7 2010.20 53 14.81 3092 2427 2.62 / 386.06 2 2
3 13 989.12 20 14.78 1704 504 3.12 / 386.56 2 3
4 13 224.48 20 14.91 614 183 3.30 / 386.74 2 4
5 8 0.08 165 14.93 262 645 3.95 / 387.39 2 6
Average= 3.87
(KJ/cycle)

Cycle 98 GMT 10/ 7/2022 0: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.56 29 14.85 440 189 0.19 / 379.72 2 3
2 7 2006.52 53 14.81 3080 2418 2.61 / 382.14 2 2
3 13 872.24 20 14.81 1548 459 3.07 / 382.60 2 3
4 13 270.80 20 14.91 685 204 3.27 / 382.80 2 4
5 8 0.08 165 14.93 261 643 3.91 / 383.44 2 6
Average= 3.87
(KJ/cycle)

Cycle 97 GMT 30/ 6/2022 2:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 30 14.87 424 189 0.19 / 375.78 2 3
2 7 2003.40 53 14.80 3083 2418 2.61 / 378.19 2 2
3 13 982.00 20 14.77 1699 502 3.11 / 378.70 2 3
4 13 225.68 20 14.91 615 183 3.29 / 378.88 2 4
5 8 0.32 165 14.93 264 650 3.94 / 379.53 2 8
Average= 3.87
(KJ/cycle)

Cycle 96 GMT 20/ 6/2022 5: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 29 14.87 425 183 0.18 / 372.19 2 3
2 7 1707.12 53 14.89 2690 2123 2.31 / 374.31 2 2
3 13 906.76 20 14.85 1601 475 2.78 / 374.79 2 4
4 13 156.96 20 14.95 509 152 2.93 / 374.94 2 3
5 8 0.24 165 14.95 261 644 3.58 / 375.59 2 5
Average= 3.87
(KJ/cycle)

Cycle 95 GMT 10/ 6/2022 5:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.92 29 14.86 435 187 0.19 / 368.51 2 3
2 3 1022.32 1 15.00 1839 28 0.22 / 368.53 2 3
3 7 1686.92 53 14.88 2667 2103 2.32 / 370.64 2 2
4 13 891.76 20 14.83 1572 466 2.78 / 371.10 2 4
5 13 147.32 20 14.96 494 148 2.93 / 371.25 2 4
6 8 -0.24 165 14.94 260 641 3.57 / 371.89 2 7
7 14 -0.24 30 14.91 259 116 3.69 / 372.01 2 3
Average= 3.88
(KJ/cycle)

Cycle 94 GMT 31/ 5/2022 5:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.16 25 14.94 431 161 0.16 / 364.90 2 3
2 10 1044.60 2 14.95 1850 55 0.22 / 364.96 2 3
3 10 1083.00 3 14.92 1908 85 0.30 / 365.04 2 3
4 7 1675.56 52 14.87 2650 2049 2.35 / 367.09 2 2
5 13 765.08 20 14.84 1395 414 2.76 / 367.51 2 4
6 13 185.24 20 14.95 558 167 2.93 / 367.67 2 4
7 8 0.28 165 14.93 262 645 3.58 / 368.32 2 4
Average= 3.88
(KJ/cycle)

Cycle 93 GMT 21/ 5/2022 5:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.20 29 14.93 431 187 0.19 / 362.30 2 3
2 3 923.92 -1 15.28 0 0 0.00 / 362.30 2 3
3 3 924.04 -1 15.30 0 0 0.00 / 362.30 2 3
4 7 943.48 52 15.11 1648 1295 1.48 / 363.60 2 2
5 13 671.48 20 15.02 1258 378 1.86 / 363.98 2 5
6 13 86.12 20 15.08 398 120 1.98 / 364.10 2 4
7 8 -0.12 165 15.04 260 645 2.62 / 364.74 2 4
Average= 3.88
(KJ/cycle)

Cycle 92 GMT 11/ 5/2022 7:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.48 29 14.86 433 187 0.19 / 359.44 3 3
2 7 1141.76 53 15.06 1915 1529 1.72 / 360.96 2 2
3 13 728.12 20 14.98 1342 402 2.12 / 361.37 2 4
4 13 66.60 20 15.04 368 111 2.23 / 361.48 2 3
5 8 0.00 165 15.00 259 641 2.87 / 362.12 2 5
Average= 3.89
(KJ/cycle)

Cycle 91 GMT 1/ 5/2022 8:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 29 14.87 409 176 0.18 / 355.51 3 3
2 7 2006.12 53 14.81 3084 2421 2.60 / 357.93 2 2
3 13 985.76 20 14.78 1701 503 3.10 / 358.43 2 4
4 13 219.68 20 14.91 603 180 3.28 / 358.61 2 4
5 8 0.00 165 14.92 260 640 3.92 / 359.25 2 5
Average= 3.90
(KJ/cycle)

Cycle 90 GMT 21/ 4/2022 10:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 29 14.86 407 175 0.18 / 351.59 2 3
2 7 2005.80 53 14.82 3076 2416 2.59 / 354.00 2 2
3 13 986.40 20 14.77 1698 502 3.09 / 354.50 2 4
4 13 232.60 20 14.91 626 187 3.28 / 354.69 2 4
5 8 0.00 165 14.93 259 638 3.92 / 355.33 2 6
Average= 3.90
(KJ/cycle)

Cycle 89 GMT 11/ 4/2022 13:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.48 29 14.85 433 186 0.19 / 347.67 2 3
2 7 2008.64 53 14.81 3089 2425 2.61 / 350.10 2 2
3 13 979.88 20 14.78 1690 500 3.11 / 350.60 2 3
4 13 208.40 20 14.91 591 176 3.29 / 350.77 2 3
5 8 0.28 165 14.92 260 640 3.93 / 351.41 2 5
Average= 3.90
(KJ/cycle)

Cycle 88 GMT 1/ 4/2022 15:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 29 14.86 405 175 0.17 / 343.66 2 3
2 7 2002.96 53 14.81 3064 2405 2.58 / 346.06 2 2
3 13 997.96 20 14.78 1716 507 3.09 / 346.57 2 4
4 13 238.68 20 14.91 631 188 3.27 / 346.76 2 4
5 13 20.60 20 14.95 294 88 3.36 / 346.85 2 3
6 8 -0.08 165 14.91 259 637 4.00 / 347.48 2 6
Average= 3.90
(KJ/cycle)

Cycle 87 GMT 22/ 3/2022 18:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 29 14.86 409 176 0.18 / 339.66 2 3
2 7 2002.20 53 14.83 3070 2413 2.59 / 342.07 2 2
3 13 980.80 20 14.79 1699 503 3.09 / 342.57 2 3
4 13 231.88 20 14.92 622 186 3.28 / 342.76 2 4
5 13 19.96 20 14.96 295 88 3.37 / 342.85 2 3
6 8 0.12 165 14.92 259 638 4.00 / 343.48 2 7
Average= 3.90
(KJ/cycle)

Cycle 86 GMT 12/ 3/2022 20:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.36 29 14.85 437 188 0.19 / 335.65 2 3
2 7 2004.48 53 14.82 3073 2414 2.60 / 338.06 2 2
3 13 992.20 20 14.78 1705 504 3.11 / 338.57 2 4
4 13 227.76 20 14.95 615 184 3.29 / 338.75 2 3
5 13 21.00 20 14.95 298 89 3.38 / 338.84 2 3
6 8 -0.12 165 14.91 260 640 4.02 / 339.48 2 4
Average= 3.90
(KJ/cycle)

Cycle 85 GMT 2/ 3/2022 23:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.96 29 14.86 432 186 0.19 / 331.63 2 3
2 7 2002.08 53 14.83 3075 2417 2.60 / 334.05 2 2
3 13 976.88 20 14.80 1685 499 3.10 / 334.55 2 4
4 13 228.52 20 14.93 621 185 3.29 / 334.73 2 4
5 13 18.80 20 14.95 293 88 3.37 / 334.82 2 4
6 8 0.24 165 14.93 261 643 4.02 / 335.46 2 7
Average= 3.90
(KJ/cycle)

Cycle 84 GMT 21/ 2/2022 1:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.44 29 14.86 437 188 0.19 / 327.60 2 3
2 7 2009.16 53 14.82 3080 2419 2.61 / 330.02 2 2
3 13 991.12 20 14.78 1711 506 3.11 / 330.53 2 3
4 13 233.56 20 14.92 628 187 3.30 / 330.72 2 4
5 13 19.12 20 14.95 294 88 3.39 / 330.80 2 3
6 8 -0.12 165 14.93 260 640 4.03 / 331.44 2 6
Average= 3.90
(KJ/cycle)

Cycle 83 GMT 11/ 2/2022 4:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 29 14.88 440 190 0.19 / 323.69 2 3
2 7 2007.56 52 14.83 3098 2389 2.58 / 326.08 2 2
3 13 984.80 20 14.79 1705 504 3.08 / 326.58 2 3
4 13 226.24 20 14.93 619 185 3.27 / 326.77 2 4
5 8 0.20 165 14.95 262 646 3.91 / 327.42 2 4
Average= 3.90
(KJ/cycle)

Cycle 82 GMT 1/ 2/2022 6:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.56 29 14.87 434 187 0.19 / 319.74 2 3
2 7 2010.04 53 14.84 3088 2429 2.62 / 322.17 2 2
3 13 982.48 20 14.77 1696 501 3.12 / 322.67 2 4
4 13 226.32 20 14.95 617 184 3.30 / 322.86 2 4
5 8 0.20 165 14.95 261 644 3.95 / 323.50 2 5
Average= 3.90
(KJ/cycle)

Cycle 81 GMT 22/ 1/2022 9:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 29 14.87 439 189 0.19 / 315.71 2 3
2 7 2004.24 53 14.84 3092 2432 2.62 / 318.14 2 2
3 13 978.88 20 14.80 1697 502 3.12 / 318.64 2 3
4 13 215.84 20 14.94 601 180 3.30 / 318.82 2 3
5 13 16.00 20 14.97 291 87 3.39 / 318.91 2 3
6 8 0.12 165 14.95 263 649 4.04 / 319.56 2 5
Average= 3.90
(KJ/cycle)

Cycle 80 GMT 12/ 1/2022 11:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.76 29 14.89 438 189 0.19 / 311.71 2 3
2 7 2005.64 52 14.83 3088 2381 2.57 / 314.09 2 2
3 13 983.56 20 14.81 1703 504 3.07 / 314.60 2 3
4 13 224.64 20 14.95 618 185 3.26 / 314.78 2 4
5 13 14.60 20 14.97 291 87 3.35 / 314.87 2 3
6 8 -0.04 165 14.94 262 646 3.99 / 315.52 2 6
Average= 3.90
(KJ/cycle)

Cycle 79 GMT 2/ 1/2022 14:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.92 29 14.89 443 191 0.19 / 307.83 2 3
2 7 2007.44 53 14.87 3090 2435 2.63 / 310.27 2 2
3 13 866.48 20 14.84 1544 458 3.08 / 310.73 2 4
4 13 152.56 20 14.97 505 151 3.24 / 310.88 2 3
5 8 0.28 165 14.96 262 647 3.88 / 311.52 2 4
Average= 3.89
(KJ/cycle)

Cycle 78 GMT 23/12/2021 16:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 29 14.91 440 190 0.19 / 303.93 2 3
2 7 2004.60 53 14.82 3072 2413 2.60 / 306.35 2 2
3 13 864.60 20 14.82 1534 455 3.06 / 306.80 2 4
4 13 245.84 20 14.96 650 194 3.25 / 306.99 2 3
5 8 -0.04 165 14.96 262 647 3.90 / 307.64 2 4
Average= 3.89
(KJ/cycle)

Cycle 77 GMT 13/12/2021 19:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 29 14.92 446 193 0.19 / 300.10 2 3
2 7 2002.80 52 14.83 3079 2374 2.57 / 302.47 2 2
3 13 880.84 20 14.84 1567 465 3.03 / 302.94 2 4
4 13 158.72 20 14.97 514 154 3.19 / 303.09 2 3
5 8 0.20 165 14.97 263 650 3.84 / 303.74 2 5
Average= 3.89
(KJ/cycle)

Cycle 76 GMT 3/12/2021 21:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.56 29 14.91 450 195 0.19 / 296.13 2 3
2 7 2007.96 53 14.84 3098 2437 2.63 / 298.57 2 2
3 13 985.36 20 14.83 1710 507 3.14 / 299.07 2 4
4 13 213.20 20 14.97 604 181 3.32 / 299.25 2 4
5 8 -0.04 165 14.99 264 653 3.97 / 299.91 2 3
Average= 3.89
(KJ/cycle)

Cycle 75 GMT 24/11/2021 0:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 29 14.93 447 194 0.19 / 292.18 2 3
2 7 2005.56 53 14.83 3077 2418 2.61 / 294.59 2 2
3 13 978.68 20 14.81 1700 504 3.12 / 295.10 2 3
4 13 214.76 20 14.97 607 182 3.30 / 295.28 2 4
5 8 0.12 165 14.98 265 655 3.95 / 295.93 2 5
Average= 3.89
(KJ/cycle)

Cycle 74 GMT 14/11/2021 2:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 29 14.93 442 191 0.19 / 288.28 2 3
2 7 2002.12 52 14.83 3075 2371 2.56 / 290.65 2 2
3 13 969.80 20 14.84 1689 501 3.06 / 291.15 2 4
4 13 203.12 20 14.98 588 176 3.24 / 291.33 2 4
5 8 0.00 165 14.99 265 655 3.90 / 291.98 2 3
Average= 3.89
(KJ/cycle)

Cycle 73 GMT 4/11/2021 5:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 29 14.93 444 192 0.19 / 284.39 2 3
2 7 2003.88 53 14.85 3081 2425 2.62 / 286.82 2 3
3 13 871.44 20 14.83 1548 459 3.08 / 287.28 2 4
4 13 143.08 20 15.00 493 148 3.22 / 287.43 2 4
5 8 0.08 165 15.01 267 661 3.89 / 288.09 2 5
Average= 3.89
(KJ/cycle)

Cycle 72 GMT 25/10/2021 7:47:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 29 14.94 455 197 0.20 / 280.39 2 3
2 7 2004.08 53 14.86 3084 2429 2.63 / 282.82 2 3
3 13 864.08 20 14.86 1537 457 3.08 / 283.28 2 4
4 13 136.84 20 15.00 480 144 3.23 / 283.42 2 3
5 8 0.12 165 15.00 267 661 3.89 / 284.08 2 3
6 14 0.12 30 14.97 267 120 4.01 / 284.20 2 4
Average= 3.89
(KJ/cycle)

Cycle 71 GMT 15/10/2021 10: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.08 29 14.95 461 200 0.20 / 276.49 2 3
2 7 2003.36 53 14.88 3089 2436 2.64 / 278.93 2 2
3 13 875.32 20 14.87 1555 462 3.10 / 279.39 2 4
4 13 139.68 20 15.02 488 147 3.25 / 279.53 2 4
5 8 -0.04 165 15.02 266 659 3.90 / 280.19 2 4
Average= 3.89
(KJ/cycle)

Cycle 70 GMT 5/10/2021 12:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 29 14.96 434 188 0.19 / 272.56 2 3
2 7 2004.08 52 14.87 3096 2394 2.58 / 274.95 2 2
3 13 973.96 20 14.87 1696 504 3.09 / 275.45 2 4
4 13 191.08 20 15.01 571 171 3.26 / 275.62 2 4
5 8 0.04 165 15.02 268 664 3.92 / 276.29 2 5
Average= 3.89
(KJ/cycle)

Cycle 69 GMT 25/ 9/2021 14:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.76 29 14.97 450 195 0.20 / 268.58 2 3
2 7 2004.88 52 14.87 3107 2402 2.60 / 270.98 2 3
3 13 862.92 20 14.88 1543 459 3.06 / 271.44 2 4
4 13 138.40 20 15.03 487 146 3.20 / 271.59 2 3
5 8 -0.08 165 15.03 265 657 3.86 / 272.25 2 5
6 14 -0.08 30 14.99 267 120 3.98 / 272.37 2 6
Average= 3.89
(KJ/cycle)

Cycle 68 GMT 15/ 9/2021 17:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 29 14.96 446 193 0.19 / 264.58 2 3
2 7 2005.96 53 14.86 3090 2434 2.63 / 267.01 2 2
3 13 858.24 20 14.87 1529 455 3.08 / 267.46 2 4
4 13 133.64 20 15.03 475 143 3.22 / 267.61 2 3
5 8 0.32 165 15.03 266 660 3.88 / 268.27 2 6
6 14 0.32 30 15.01 265 119 4.00 / 268.39 2 6
Average= 3.89
(KJ/cycle)

Cycle 67 GMT 5/ 9/2021 19:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 29 14.96 450 195 0.20 / 260.50 2 3
2 7 2003.84 53 14.86 3082 2427 2.62 / 262.93 2 2
3 13 969.40 20 14.86 1687 501 3.12 / 263.43 2 4
4 13 201.72 20 15.03 585 176 3.30 / 263.60 2 4
5 8 0.04 165 15.03 266 660 3.96 / 264.26 2 4
6 14 0.04 30 15.01 268 121 4.08 / 264.38 2 6
Average= 3.89
(KJ/cycle)

Cycle 66 GMT 26/ 8/2021 22: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 29 14.97 441 191 0.19 / 256.45 2 3
2 7 2006.80 52 14.86 3090 2388 2.58 / 258.84 2 3
3 13 971.24 20 14.84 1688 501 3.08 / 259.34 2 4
4 13 200.00 20 15.01 581 174 3.25 / 259.52 2 4
5 8 0.08 165 15.03 268 665 3.92 / 260.18 2 4
6 14 0.08 30 15.00 268 121 4.04 / 260.30 2 6
Average= 3.89
(KJ/cycle)

Cycle 65 GMT 17/ 8/2021 0:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 29 14.97 439 191 0.19 / 252.57 2 3
2 7 2004.56 53 14.85 3094 2435 2.63 / 255.00 2 3
3 13 846.76 20 14.90 1518 452 3.08 / 255.46 2 4
4 13 134.48 20 15.05 479 144 3.22 / 255.60 2 3
5 8 0.00 165 15.04 267 663 3.88 / 256.26 2 6
Average= 3.88
(KJ/cycle)

Cycle 64 GMT 7/ 8/2021 2:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.64 29 14.99 459 200 0.20 / 248.60 2 3
2 7 2004.16 52 14.87 3091 2390 2.59 / 250.99 2 2
3 13 871.44 20 14.89 1551 462 3.05 / 251.45 2 4
4 13 141.76 20 15.06 493 148 3.20 / 251.60 2 3
5 8 -0.04 165 15.05 266 661 3.86 / 252.26 2 3
6 14 -0.04 30 15.03 266 120 3.98 / 252.38 2 5
Average= 3.88
(KJ/cycle)

Cycle 63 GMT 28/ 7/2021 5:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 29 15.00 440 191 0.19 / 244.63 2 3
2 7 2002.72 53 14.88 3085 2433 2.62 / 247.06 2 3
3 13 967.48 20 14.88 1684 501 3.13 / 247.56 2 4
4 13 184.68 20 15.05 565 170 3.30 / 247.73 2 3
5 8 0.24 165 15.06 268 666 3.96 / 248.40 2 4
Average= 3.88
(KJ/cycle)

Cycle 62 GMT 18/ 7/2021 7:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 29 15.00 452 197 0.20 / 240.78 2 3
2 7 2008.08 52 14.89 3093 2395 2.59 / 243.17 2 3
3 13 863.00 20 14.90 1539 459 3.05 / 243.63 2 4
4 13 135.52 20 15.04 481 145 3.19 / 243.78 2 4
5 8 -0.08 165 15.06 265 658 3.85 / 244.44 2 3
Average= 3.88
(KJ/cycle)

Cycle 61 GMT 8/ 7/2021 10: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 28 15.00 433 182 0.18 / 236.80 2 3
2 3 1017.04 1 15.08 1834 28 0.21 / 236.83 2 3
3 7 2002.04 53 14.90 3094 2443 2.65 / 239.27 2 2
4 13 971.88 20 14.89 1693 504 3.16 / 239.78 2 4
5 13 120.96 20 15.06 458 138 3.29 / 239.92 2 3
6 8 0.12 165 15.05 268 666 3.96 / 240.58 2 4
Average= 3.88
(KJ/cycle)

Cycle 60 GMT 28/ 6/2021 12:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.68 28 15.01 453 190 0.19 / 232.72 2 3
2 7 2005.52 53 14.90 3093 2443 2.63 / 235.16 2 3
3 13 1129.76 20 14.88 1908 568 3.20 / 235.73 2 4
4 13 312.52 20 15.05 754 227 3.43 / 235.96 2 5
5 8 0.12 165 15.07 268 666 4.09 / 236.62 2 7
Average= 3.88
(KJ/cycle)

Cycle 59 GMT 18/ 6/2021 14:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.24 28 15.02 455 191 0.19 / 228.69 2 3
2 7 2002.88 53 14.89 3095 2442 2.63 / 231.14 2 3
3 13 862.24 20 14.94 1541 460 3.09 / 231.60 2 4
4 13 140.12 20 15.09 492 148 3.24 / 231.75 2 4
5 8 0.28 165 15.08 266 662 3.90 / 232.41 2 6
6 14 0.28 30 15.06 267 121 4.03 / 232.53 2 7
Average= 3.88
(KJ/cycle)

Cycle 58 GMT 8/ 6/2021 17:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 28 15.01 455 191 0.19 / 224.72 2 3
2 7 2001.60 53 14.92 3091 2444 2.64 / 227.17 2 3
3 13 958.72 20 14.93 1672 499 3.13 / 227.67 2 4
4 13 188.20 20 15.09 567 171 3.31 / 227.84 2 4
5 8 0.20 165 15.09 267 665 3.97 / 228.50 2 6
Average= 3.87
(KJ/cycle)

Cycle 57 GMT 29/ 5/2021 19:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 28 15.02 448 188 0.19 / 220.74 2 3
2 7 2004.36 52 14.89 3092 2394 2.58 / 223.14 2 2
3 13 858.16 20 14.95 1536 459 3.04 / 223.60 2 4
4 13 134.76 20 15.08 483 146 3.19 / 223.74 2 4
5 8 -0.16 165 15.09 268 667 3.85 / 224.41 2 3
6 14 -0.16 30 15.07 268 121 3.98 / 224.53 2 5
Average= 3.87
(KJ/cycle)

Cycle 56 GMT 19/ 5/2021 22: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.96 28 15.03 440 185 0.19 / 216.77 2 3
2 7 2007.64 53 14.90 3101 2449 2.63 / 219.22 2 3
3 13 973.68 20 14.90 1691 504 3.14 / 219.72 2 5
4 13 188.28 20 15.08 566 171 3.31 / 219.89 2 4
5 8 0.24 165 15.09 266 662 3.97 / 220.56 2 8
Average= 3.87
(KJ/cycle)

Cycle 55 GMT 10/ 5/2021 0:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.20 28 15.04 446 188 0.19 / 212.76 2 3
2 7 2008.40 53 14.89 3095 2442 2.63 / 215.20 2 2
3 13 850.16 20 14.96 1521 455 3.09 / 215.66 2 4
4 13 135.72 20 15.11 483 146 3.23 / 215.81 2 3
5 8 0.00 165 15.09 265 660 3.89 / 216.47 2 5
6 14 0.00 30 15.07 265 120 4.01 / 216.59 3 5
Average= 3.87
(KJ/cycle)

Cycle 54 GMT 30/ 4/2021 2:55: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.36 28 15.02 445 187 0.19 / 208.90 2 3
2 7 2006.32 52 14.91 3100 2403 2.59 / 211.30 2 2
3 13 867.72 20 14.95 1547 463 3.05 / 211.76 2 4
4 13 145.36 20 15.11 498 150 3.20 / 211.91 2 4
5 8 0.20 165 15.10 266 663 3.87 / 212.57 2 5
Average= 3.86
(KJ/cycle)

Cycle 53 GMT 20/ 4/2021 5:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.76 28 15.03 451 190 0.19 / 204.92 2 3
2 7 2006.56 53 14.91 3096 2447 2.64 / 207.37 2 3
3 13 969.64 20 14.92 1690 504 3.14 / 207.87 2 4
4 13 197.64 20 15.09 579 175 3.32 / 208.05 2 4
5 8 0.04 165 15.10 266 663 3.98 / 208.71 2 4
Average= 3.86
(KJ/cycle)

Cycle 52 GMT 10/ 4/2021 7:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.72 28 15.04 446 188 0.19 / 201.08 2 3
2 7 2006.12 52 14.92 3081 2390 2.58 / 203.47 2 2
3 13 851.32 20 14.96 1518 454 3.03 / 203.93 2 4
4 13 126.16 20 15.12 465 141 3.17 / 204.07 2 4
5 8 0.16 165 15.11 266 663 3.84 / 204.73 2 5
Average= 3.86
(KJ/cycle)

Cycle 51 GMT 31/ 3/2021 10:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.20 28 15.04 446 188 0.19 / 197.14 2 3
2 7 2004.64 53 14.91 3087 2439 2.63 / 199.58 2 2
3 13 856.12 20 14.96 1528 457 3.08 / 200.04 2 4
4 13 235.48 20 15.10 640 193 3.28 / 200.23 2 4
5 8 0.24 165 15.09 267 665 3.94 / 200.89 2 4
Average= 3.86
(KJ/cycle)

Cycle 50 GMT 21/ 3/2021 12:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.00 28 15.04 441 186 0.19 / 193.17 2 3
2 7 2004.28 53 14.91 3090 2442 2.63 / 195.61 2 2
3 13 973.00 20 14.94 1693 506 3.13 / 196.12 2 3
4 13 192.28 20 15.11 571 173 3.31 / 196.29 2 4
5 8 0.16 165 15.11 266 663 3.97 / 196.95 2 6
Average= 3.86
(KJ/cycle)

Cycle 49 GMT 11/ 3/2021 15: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.64 28 15.04 439 185 0.18 / 189.24 2 3
2 7 2002.60 52 14.94 3078 2391 2.58 / 191.63 2 2
3 13 979.96 20 14.94 1703 509 3.08 / 192.14 2 3
4 13 198.44 20 15.11 579 175 3.26 / 192.32 2 4
5 8 0.12 165 15.11 266 663 3.92 / 192.98 2 6
Average= 3.86
(KJ/cycle)

Cycle 48 GMT 1/ 3/2021 17:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.76 28 15.04 443 187 0.19 / 185.31 2 3
2 7 2003.56 53 14.92 3090 2443 2.63 / 187.76 2 3
3 13 846.32 20 14.98 1518 455 3.08 / 188.21 2 4
4 13 222.16 20 15.09 615 186 3.27 / 188.40 2 4
5 8 0.12 165 15.11 265 661 3.93 / 189.06 2 4
Average= 3.86
(KJ/cycle)

Cycle 47 GMT 19/ 2/2021 20:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.80 28 15.04 438 184 0.18 / 181.34 2 3
2 7 2006.80 53 14.93 3094 2448 2.63 / 183.79 2 2
3 13 969.04 20 14.93 1687 504 3.14 / 184.29 2 4
4 13 196.20 20 15.12 579 175 3.31 / 184.47 2 3
5 8 0.20 165 15.11 265 661 3.97 / 185.13 2 4
Average= 3.86
(KJ/cycle)

Cycle 46 GMT 9/ 2/2021 22:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.92 28 15.02 436 183 0.18 / 177.44 2 3
2 7 2005.12 53 14.91 3096 2447 2.63 / 179.89 2 3
3 13 863.24 20 14.96 1543 462 3.09 / 180.35 2 4
4 13 139.80 20 15.10 486 147 3.24 / 180.50 2 3
5 8 0.16 165 15.10 264 658 3.90 / 181.16 2 5
Average= 3.85
(KJ/cycle)

Cycle 45 GMT 31/ 1/2021 1: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.40 28 15.04 450 190 0.19 / 173.55 2 3
2 7 2003.48 53 14.91 3093 2444 2.63 / 176.00 2 3
3 13 855.52 20 14.95 1526 456 3.09 / 176.45 2 4
4 13 141.24 20 15.08 490 148 3.24 / 176.60 2 3
5 8 0.12 165 15.09 264 657 3.90 / 177.26 2 5
Average= 3.85
(KJ/cycle)

Cycle 44 GMT 21/ 1/2021 3:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.32 28 15.04 444 187 0.19 / 169.62 2 3
2 7 2004.00 53 14.92 3086 2440 2.63 / 172.06 2 2
3 13 848.48 20 14.97 1515 454 3.08 / 172.51 2 3
4 13 234.16 20 15.08 634 191 3.27 / 172.70 2 3
5 8 0.00 165 15.10 266 663 3.93 / 173.36 2 5
Average= 3.85
(KJ/cycle)

Cycle 43 GMT 11/ 1/2021 5:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.72 28 15.05 450 190 0.19 / 165.72 2 3
2 7 2003.68 53 14.90 3094 2443 2.63 / 168.16 2 3
3 13 856.52 20 14.96 1531 458 3.09 / 168.62 2 3
4 13 137.04 20 15.13 483 146 3.24 / 168.77 2 3
5 8 0.08 165 15.12 265 661 3.90 / 169.43 2 5
Average= 3.85
(KJ/cycle)

Cycle 42 GMT 1/ 1/2021 8: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.48 28 15.05 450 190 0.19 / 161.62 2 3
2 7 2001.68 53 14.92 3094 2447 2.64 / 164.07 2 3
3 13 962.52 20 14.94 1680 502 3.14 / 164.57 2 4
4 13 194.96 20 15.12 577 174 3.31 / 164.75 2 3
5 8 0.12 165 15.12 266 664 3.98 / 165.41 2 3
6 14 0.12 30 15.08 265 120 4.10 / 165.53 3 4
Average= 3.85
(KJ/cycle)

Cycle 41 GMT 22/12/2020 10:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.32 28 15.06 441 186 0.19 / 157.64 2 3
2 7 2003.80 53 14.93 3088 2444 2.63 / 160.09 2 3
3 13 967.04 20 14.97 1687 505 3.13 / 160.59 2 4
4 13 196.60 20 15.13 581 176 3.31 / 160.77 2 4
5 8 0.12 165 15.12 267 666 3.98 / 161.44 2 7
Average= 3.84
(KJ/cycle)

Cycle 40 GMT 12/12/2020 12:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 28 15.06 451 190 0.19 / 153.75 2 3
2 7 2003.76 53 14.92 3088 2442 2.63 / 156.19 2 3
3 13 847.68 20 14.98 1515 454 3.09 / 156.64 2 4
4 13 138.92 20 15.15 488 148 3.23 / 156.79 2 4
5 8 0.28 165 15.13 267 667 3.90 / 157.46 2 3
Average= 3.84
(KJ/cycle)

Cycle 39 GMT 2/12/2020 15:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.76 28 15.07 449 189 0.19 / 149.79 2 3
2 7 2002.44 53 14.93 3097 2451 2.64 / 152.24 2 3
3 13 854.00 20 15.00 1529 459 3.10 / 152.70 2 4
4 13 234.32 20 15.13 637 193 3.29 / 152.89 2 4
5 8 -0.08 165 15.13 266 664 3.96 / 153.56 2 6
Average= 3.84
(KJ/cycle)

Cycle 38 GMT 22/11/2020 17:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.20 28 15.07 445 188 0.19 / 145.86 2 3
2 7 2003.04 52 14.93 3091 2400 2.59 / 148.26 2 2
3 13 966.36 20 14.98 1686 505 3.09 / 148.77 2 4
4 13 192.20 20 15.13 571 173 3.27 / 148.94 2 4
5 8 0.04 165 15.13 266 664 3.93 / 149.60 2 4
Average= 3.84
(KJ/cycle)

Cycle 37 GMT 12/11/2020 20: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.48 28 15.07 447 189 0.19 / 141.92 2 3
2 7 2004.04 52 14.93 3090 2399 2.59 / 144.32 2 3
3 13 968.96 20 14.97 1694 507 3.09 / 144.83 2 3
4 13 204.36 20 15.10 589 178 3.27 / 145.01 2 4
5 8 0.16 165 15.14 266 664 3.94 / 145.67 2 4
Average= 3.83
(KJ/cycle)

Cycle 36 GMT 2/11/2020 22:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.72 28 15.07 453 191 0.19 / 137.94 2 3
2 7 2004.32 53 14.94 3098 2453 2.64 / 140.39 2 3
3 13 965.28 20 14.96 1682 503 3.15 / 140.89 2 4
4 13 196.12 20 15.14 578 175 3.32 / 141.07 2 3
5 8 0.08 165 15.14 268 669 3.99 / 141.74 2 4
Average= 3.83
(KJ/cycle)

Cycle 35 GMT 24/10/2020 1: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.60 28 15.06 443 187 0.19 / 134.02 2 3
2 7 2009.64 53 14.94 3102 2456 2.64 / 136.47 2 3
3 13 862.56 20 14.99 1538 461 3.10 / 136.93 2 3
4 13 147.44 20 15.14 500 151 3.26 / 137.08 2 3
5 8 0.00 165 15.14 264 659 3.92 / 137.74 2 9
Average= 3.83
(KJ/cycle)

Cycle 34 GMT 14/10/2020 3: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.48 28 15.06 447 188 0.19 / 130.11 2 3
2 7 2005.64 53 14.93 3100 2453 2.64 / 132.56 2 3
3 13 866.76 20 14.99 1541 462 3.10 / 133.02 2 4
4 13 141.84 20 15.13 491 149 3.25 / 133.17 2 4
5 8 0.16 165 15.13 264 659 3.91 / 133.83 2 5
Average= 3.82
(KJ/cycle)

Cycle 33 GMT 4/10/2020 5:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 28 15.08 453 191 0.19 / 126.12 2 3
2 7 2003.28 53 14.94 3101 2455 2.65 / 128.58 2 3
3 13 964.44 20 14.95 1682 503 3.15 / 129.08 2 4
4 13 188.28 20 15.13 566 171 3.32 / 129.25 2 3
5 8 0.16 165 15.13 267 667 3.99 / 129.92 2 9
Average= 3.82
(KJ/cycle)

Cycle 32 GMT 24/ 9/2020 8: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 28 15.07 446 188 0.19 / 122.17 2 3
2 7 2003.92 53 14.96 3123 2476 2.66 / 124.65 2 3
3 13 858.08 20 15.01 1532 460 3.12 / 125.11 2 4
4 13 151.56 20 15.16 511 155 3.28 / 125.27 2 3
5 8 0.08 165 15.14 266 664 3.94 / 125.93 2 5
Average= 3.82
(KJ/cycle)

Cycle 31 GMT 14/ 9/2020 10:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 28 15.08 448 189 0.19 / 118.28 2 3
2 7 2003.52 53 14.94 3083 2441 2.63 / 120.72 2 3
3 13 848.48 20 14.98 1518 455 3.09 / 121.17 2 4
4 13 137.52 20 15.12 487 147 3.23 / 121.32 2 3
5 8 0.16 165 15.14 267 667 3.90 / 121.99 2 3
Average= 3.81
(KJ/cycle)

Cycle 30 GMT 4/ 9/2020 12:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.72 28 15.09 456 193 0.19 / 114.32 2 3
2 7 2003.56 53 14.93 3088 2444 2.64 / 116.77 2 3
3 13 847.00 20 15.02 1520 457 3.09 / 117.22 2 4
4 13 230.72 20 15.13 629 190 3.28 / 117.41 2 4
5 8 0.04 165 15.14 270 674 3.96 / 118.09 2 3
Average= 3.81
(KJ/cycle)

Cycle 29 GMT 25/ 8/2020 15: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.28 28 15.08 453 191 0.19 / 110.38 2 3
2 7 2006.04 53 14.95 3095 2452 2.64 / 112.84 2 3
3 13 831.96 20 15.00 1491 447 3.09 / 113.28 2 4
4 13 202.32 20 15.14 586 177 3.27 / 113.46 2 3
5 8 -0.04 165 15.16 267 668 3.94 / 114.13 2 4
Average= 3.80
(KJ/cycle)

Cycle 28 GMT 15/ 8/2020 17:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.92 28 15.08 454 192 0.19 / 106.42 2 3
2 7 2007.32 53 14.96 3097 2456 2.65 / 108.87 2 3
3 13 846.92 20 15.01 1517 455 3.10 / 109.33 2 4
4 13 228.32 20 15.14 630 191 3.29 / 109.52 2 4
5 8 0.24 165 15.15 269 672 3.97 / 110.19 2 4
Average= 3.80
(KJ/cycle)

Cycle 27 GMT 5/ 8/2020 20:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.44 28 15.09 455 192 0.19 / 102.46 2 3
2 7 2001.88 53 14.95 3095 2452 2.64 / 104.91 2 3
3 13 840.08 20 15.02 1514 455 3.10 / 105.37 2 3
4 13 218.60 20 15.13 615 186 3.29 / 105.56 2 4
5 8 0.00 165 15.15 269 672 3.96 / 106.23 2 5
Average= 3.79
(KJ/cycle)

Cycle 26 GMT 26/ 7/2020 22:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.20 28 15.10 451 191 0.19 / 98.52 2 3
2 7 2002.12 53 14.95 3088 2447 2.64 / 100.96 2 3
3 13 844.76 20 15.01 1516 455 3.09 / 101.42 2 5
4 13 217.64 20 15.15 614 186 3.28 / 101.60 2 4
5 8 0.08 165 15.16 266 665 3.94 / 102.27 2 6
Average= 3.79
(KJ/cycle)

Cycle 25 GMT 17/ 7/2020 1: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 28 15.10 453 192 0.19 / 94.54 2 3
2 7 2003.48 53 14.95 3093 2451 2.64 / 96.99 2 3
3 13 953.72 20 15.00 1674 502 3.14 / 97.49 2 4
4 13 174.88 20 15.17 546 166 3.31 / 97.66 2 3
5 8 0.12 165 15.16 268 670 3.98 / 98.33 2 5
Average= 3.78
(KJ/cycle)

Cycle 24 GMT 7/ 7/2020 3:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 28 15.10 452 191 0.19 / 90.54 2 3
2 7 2004.20 53 14.96 3102 2460 2.65 / 93.00 2 3
3 13 956.12 20 15.01 1676 503 3.15 / 93.50 2 4
4 13 178.12 20 15.16 554 168 3.32 / 93.67 2 4
5 8 0.12 165 15.17 270 676 4.00 / 94.35 2 4
Average= 3.77
(KJ/cycle)

Cycle 23 GMT 27/ 6/2020 5:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 28 15.09 430 182 0.18 / 86.51 2 3
2 7 2004.24 53 14.95 3094 2452 2.63 / 88.97 2 3
3 13 834.56 20 15.03 1506 453 3.09 / 89.42 2 4
4 13 119.52 20 15.17 458 139 3.22 / 89.56 2 3
5 8 0.08 165 15.17 267 668 3.89 / 90.23 2 5
6 14 0.08 30 15.15 268 122 4.01 / 90.35 2 6
Average= 3.76
(KJ/cycle)

Cycle 22 GMT 17/ 6/2020 8:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 28 15.10 429 181 0.18 / 82.50 2 3
2 7 2001.96 53 14.97 3099 2459 2.64 / 84.96 2 3
3 13 829.88 20 15.02 1494 449 3.09 / 85.41 2 4
4 13 118.52 20 15.17 457 139 3.23 / 85.54 2 3
5 8 -0.24 165 15.15 267 667 3.90 / 86.21 2 6
6 14 -0.24 30 15.13 267 121 4.02 / 86.33 2 4
Average= 3.75
(KJ/cycle)

Cycle 21 GMT 7/ 6/2020 10:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.16 28 15.11 452 191 0.19 / 78.59 2 3
2 7 2005.16 53 14.96 3102 2460 2.65 / 81.05 2 3
3 13 845.44 20 15.03 1520 457 3.11 / 81.50 2 4
4 13 127.72 20 15.18 472 143 3.25 / 81.65 2 3
5 8 0.28 165 15.16 268 670 3.92 / 82.32 2 5
Average= 3.74
(KJ/cycle)

Cycle 20 GMT 28/ 5/2020 12:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 28 15.11 429 182 0.18 / 74.48 2 3
2 7 2004.64 53 14.97 3100 2460 2.64 / 76.94 2 3
3 13 961.12 20 15.01 1680 504 3.15 / 77.44 2 5
4 13 160.92 20 15.19 528 160 3.31 / 77.60 2 3
5 8 0.16 165 15.18 268 671 3.98 / 78.27 2 5
6 14 0.16 30 15.16 267 121 4.10 / 78.40 2 4
Average= 3.73
(KJ/cycle)

Cycle 19 GMT 18/ 5/2020 15:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.80 28 15.11 455 193 0.19 / 70.49 2 3
2 7 2002.36 53 14.97 3100 2460 2.65 / 72.95 2 3
3 13 959.32 20 15.01 1680 504 3.16 / 73.46 2 4
4 13 170.60 20 15.18 541 164 3.32 / 73.62 2 4
5 8 0.12 165 15.18 270 676 4.00 / 74.30 2 4
Average= 3.71
(KJ/cycle)

Cycle 18 GMT 8/ 5/2020 17:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 28 15.11 435 184 0.18 / 66.56 2 3
2 7 2007.68 53 14.98 3104 2464 2.65 / 69.03 2 3
3 13 842.32 20 15.05 1510 455 3.10 / 69.48 2 4
4 13 124.36 20 15.18 467 142 3.24 / 69.63 2 3
5 8 0.04 165 15.19 269 674 3.92 / 70.30 2 4
Average= 3.70
(KJ/cycle)

Cycle 17 GMT 28/ 4/2020 20: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.16 28 15.11 455 193 0.19 / 62.29 2 3
2 7 2002.64 53 14.98 3083 2448 2.64 / 64.74 2 4
3 13 957.00 20 15.03 1670 502 3.14 / 65.24 2 4
4 13 171.28 20 15.19 543 165 3.31 / 65.41 2 3
5 8 -0.08 165 15.18 268 671 3.98 / 66.08 2 7
6 14 -0.08 75 15.15 265 301 4.28 / 66.38 2 8
Average= 3.69
(KJ/cycle)

Cycle 16 GMT 18/ 4/2020 22:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 28 15.12 427 181 0.18 / 58.40 2 3
2 7 2002.84 53 14.96 3085 2446 2.63 / 60.84 2 3
3 13 831.12 20 15.05 1495 450 3.08 / 61.29 2 4
4 13 116.76 20 15.19 455 138 3.22 / 61.43 2 3
5 8 0.20 165 15.17 268 671 3.89 / 62.10 2 4
Average= 3.65
(KJ/cycle)

Cycle 15 GMT 9/ 4/2020 0:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.52 27 15.12 449 183 0.18 / 54.42 2 3
2 7 2004.68 53 14.98 3095 2457 2.64 / 56.87 2 3
3 13 958.88 20 15.03 1680 505 3.15 / 57.38 2 5
4 13 166.60 20 15.19 536 163 3.31 / 57.54 2 4
5 8 0.04 165 15.18 269 674 3.98 / 58.22 2 7
Average= 3.64
(KJ/cycle)

Cycle 14 GMT 30/ 3/2020 3:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 27 15.12 426 174 0.17 / 50.52 2 3
2 7 2002.56 53 15.00 3100 2464 2.64 / 52.98 2 3
3 13 822.16 20 15.06 1480 446 3.08 / 53.43 2 4
4 13 113.60 20 15.20 449 136 3.22 / 53.56 2 3
5 8 -0.04 165 15.18 268 671 3.89 / 54.23 2 5
Average= 3.62
(KJ/cycle)

Cycle 13 GMT 20/ 3/2020 5:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 27 15.13 428 175 0.17 / 46.60 2 3
2 7 2002.52 52 14.98 3079 2398 2.57 / 49.00 2 3
3 13 955.40 20 15.03 1674 503 3.08 / 49.51 2 6
4 13 163.16 20 15.19 530 161 3.24 / 49.67 2 4
5 8 0.20 165 15.19 269 674 3.91 / 50.34 2 4
Average= 3.60
(KJ/cycle)

Cycle 12 GMT 10/ 3/2020 8: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.68 27 15.13 443 181 0.18 / 42.74 2 3
2 7 2005.64 52 15.00 3104 2421 2.60 / 45.16 2 3
3 13 826.72 20 15.04 1491 448 3.05 / 45.61 2 5
4 13 117.84 20 15.21 458 139 3.19 / 45.75 2 4
5 8 0.12 165 15.19 271 679 3.87 / 46.43 2 4
Average= 3.57
(KJ/cycle)

Cycle 11 GMT 29/ 2/2020 10:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 27 15.13 448 183 0.18 / 38.71 2 3
2 7 2004.76 53 15.01 3100 2466 2.65 / 41.18 2 3
3 13 964.28 18 15.04 1684 456 3.11 / 41.64 2 4
4 13 205.88 18 15.19 594 162 3.27 / 41.80 2 3
5 13 18.84 18 15.23 305 84 3.35 / 41.88 2 3
6 8 0.16 165 15.19 271 679 4.03 / 42.56 2 4
Average= 3.55
(KJ/cycle)

Cycle 10 GMT 19/ 2/2020 12:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.72 27 15.13 455 186 0.19 / 34.76 2 3
2 7 2009.00 52 15.02 3115 2433 2.62 / 37.19 2 4
3 13 837.44 18 15.08 1504 408 3.03 / 37.60 2 4
4 13 225.88 18 15.20 628 172 3.20 / 37.77 2 3
5 13 17.28 18 15.22 302 83 3.28 / 37.86 2 3
6 8 -0.04 165 15.18 269 674 3.96 / 38.53 2 4
Average= 3.50
(KJ/cycle)

Cycle 9 GMT 9/ 2/2020 15: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.08 27 15.14 452 185 0.18 / 30.90 2 3
2 7 2006.64 53 15.00 3098 2463 2.65 / 33.36 2 4
3 13 837.12 18 15.07 1507 409 3.06 / 33.77 2 4
4 13 135.00 18 15.21 486 133 3.19 / 33.90 2 3
5 8 0.00 165 15.20 269 675 3.86 / 34.57 2 6
Average= 3.46
(KJ/cycle)

Cycle 8 GMT 30/ 1/2020 17:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.16 27 15.14 452 185 0.18 / 27.02 2 3
2 7 2003.88 53 15.04 3111 2480 2.66 / 29.50 2 3
3 13 823.36 18 15.07 1488 404 3.07 / 29.91 2 4
4 13 114.48 18 15.23 457 125 3.19 / 30.03 2 3
5 8 0.16 165 15.21 271 680 3.87 / 30.71 2 5
Average= 3.41
(KJ/cycle)

Cycle 7 GMT 20/ 1/2020 19:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 27 15.14 460 188 0.19 / 23.11 2 3
2 7 2003.20 53 15.01 3101 2467 2.65 / 25.58 2 3
3 13 825.72 18 15.09 1496 406 3.06 / 25.98 2 6
4 13 215.00 18 15.19 613 168 3.23 / 26.15 2 3
5 8 0.04 165 15.20 273 685 3.91 / 26.84 2 5
Average= 3.35
(KJ/cycle)

Cycle 6 GMT 10/ 1/2020 21:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 26 15.13 452 178 0.18 / 19.15 2 3
2 3 1055.28 2 15.18 1887 57 0.24 / 19.20 2 5
3 7 2005.24 53 15.02 3095 2464 2.70 / 21.67 2 4
4 13 823.60 18 15.07 1486 403 3.10 / 22.07 2 4
5 13 212.68 18 15.21 609 167 3.27 / 22.24 2 3
6 8 0.00 165 15.20 274 687 3.96 / 22.92 2 4
Average= 3.27
(KJ/cycle)

Cycle 5 GMT 1/ 1/2020 0: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 25 15.15 446 169 0.17 / 15.19 2 3
2 10 1010.80 2 15.14 1803 55 0.22 / 15.25 2 3
3 7 2003.32 53 15.02 3089 2459 2.68 / 17.71 2 3
4 13 834.52 18 15.08 1506 409 3.09 / 18.12 2 5
5 13 212.80 18 15.19 613 168 3.26 / 18.28 2 3
6 8 0.00 165 15.19 273 684 3.94 / 18.97 2 5
Average= 3.16
(KJ/cycle)

Cycle 4 GMT 22/12/2019 2:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.56 25 15.14 453 171 0.17 / 11.59 2 2
2 7 1505.88 74 14.93 2393 2644 2.82 / 14.24 2 4
3 13 76.28 18 15.24 393 108 2.92 / 14.34 2 3
4 8 0.24 165 15.21 271 680 3.60 / 15.02 2 6
Average= 3.00
(KJ/cycle)

Cycle 3 GMT 21/12/2019 2:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 25 15.15 445 169 0.17 / 7.93 2 3
2 3 1029.32 1 15.22 1863 28 0.20 / 7.96 2 4
3 7 1522.56 74 14.92 2415 2666 2.86 / 10.63 2 3
4 13 88.28 18 15.23 413 113 2.98 / 10.74 2 3
5 8 -0.04 165 15.22 271 681 3.66 / 11.42 2 4
Average= 2.86
(KJ/cycle)

Cycle 2 GMT 20/12/2019 3:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 26 15.18 439 173 0.17 / 4.32 2 3
2 3 965.40 -1 15.49 0 0 0.00 / 4.32 2 3
3 7 1520.60 74 14.92 2409 2660 2.83 / 6.98 2 3
4 13 79.04 18 15.25 393 108 2.94 / 7.09 2 3
5 8 -0.04 165 15.21 270 678 3.62 / 7.76 2 5
Average= 2.59
(KJ/cycle)

Cycle 1 GMT 19/12/2019 3:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 23 15.35 413 146 0.15 / 1.53 2 3
2 3 1079.24 2 15.19 1916 58 0.20 / 1.59 2 3
3 7 996.72 74 15.07 1685 1879 2.08 / 3.47 2 4
4 8 0.00 165 15.24 269 676 2.76 / 4.15 2 8
Average= 2.07
(KJ/cycle)

Cycle 0 GMT 18/12/2019 17:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 57.28 22 15.46 340 116 0.12 / 0.12 3 3
2 7 71.12 74 15.43 351 401 0.52 / 0.52 3 3
3 8 0.20 240 15.42 235 870 1.39 / 1.39 3 11
Average= 1.39