SIO Argo Site:
Pump Diagnostics Page   



Serial= 8566 WMO= 3901276

Return

←PreviousNext→

Bug in float firmware: Transmitted values shaded red are not valid


Cycle 270 GMT 22/12/2024 22:14:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 29 14.34 0 0 0.00 / 1139.51 2 2
2 7 2006.28 46 13.64 2939 1844 1.84 / 1141.35 2 2
3 13 1738.80 21 13.67 2654 762 2.61 / 1142.11 2 2
4 13 1158.00 21 13.78 1922 556 3.16 / 1142.67 2 2
5 13 447.60 21 14.05 971 286 3.45 / 1142.96 2 2
6 13 41.12 21 14.29 353 106 3.55 / 1143.06 2 2
7 8 0.12 165 14.26 299 704 4.26 / 1143.77 2 2
Average= 4.22
(KJ/cycle)

Cycle 269 GMT 12/12/2024 22:47:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 29 14.36 0 0 0.00 / 1135.27 2 2
2 7 2007.36 47 13.63 2952 1891 1.89 / 1137.16 2 2
3 13 1592.96 21 13.71 2462 709 2.60 / 1137.87 2 2
4 13 1048.40 21 13.82 1770 514 3.11 / 1138.38 2 2
5 13 465.84 21 14.04 997 294 3.41 / 1138.68 2 2
6 13 42.28 21 14.27 361 108 3.52 / 1138.79 2 2
7 8 -0.08 165 14.25 307 722 4.24 / 1139.51 2 2
Average= 4.22
(KJ/cycle)

Cycle 268 GMT 2/12/2024 23:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 29 14.40 0 0 0.00 / 1131.16 2 2
2 7 2009.72 46 13.68 2948 1855 1.86 / 1133.01 2 2
3 13 1477.20 21 13.78 2338 677 2.53 / 1133.69 2 2
4 13 1070.88 21 13.85 1790 521 3.05 / 1134.21 2 2
5 13 364.32 21 14.12 850 252 3.30 / 1134.46 2 2
6 13 25.12 21 14.31 334 100 3.40 / 1134.56 2 2
7 8 0.00 165 14.27 301 709 4.11 / 1135.27 2 2
Average= 4.22
(KJ/cycle)

Cycle 267 GMT 22/11/2024 23:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 29 14.60 0 0 0.00 / 1126.92 2 2
2 7 2003.48 46 13.73 2933 1852 1.85 / 1128.78 2 2
3 13 1605.72 21 13.79 2482 719 2.57 / 1129.50 2 2
4 13 1178.36 21 13.86 1941 565 3.14 / 1130.06 2 2
5 13 460.00 21 14.12 984 292 3.43 / 1130.35 2 2
6 13 20.16 21 14.36 326 98 3.53 / 1130.45 2 2
7 8 0.28 165 14.32 299 706 4.23 / 1131.16 2 2
Average= 4.22
(KJ/cycle)

Cycle 266 GMT 13/11/2024 0: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 28 14.73 0 0 0.00 / 1122.61 2 2
2 3 1034.60 1 15.02 0 0 0.00 / 1122.61 2 2
3 7 2003.44 46 13.85 2953 1881 1.88 / 1124.49 2 2
4 13 1738.84 21 13.89 2614 762 2.64 / 1125.25 2 2
5 13 1148.64 21 14.00 1899 558 3.20 / 1125.81 2 2
6 13 421.16 21 14.31 930 279 3.48 / 1126.09 2 2
7 13 14.48 21 14.55 326 100 3.58 / 1126.19 2 2
8 8 -0.04 165 14.51 306 733 4.31 / 1126.92 2 2
Average= 4.22
(KJ/cycle)

Cycle 265 GMT 3/11/2024 0:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 28 14.79 0 0 0.00 / 1118.40 2 2
2 7 2002.88 46 13.94 2951 1892 1.89 / 1120.30 2 2
3 13 1726.16 21 13.97 2642 775 2.67 / 1121.07 2 2
4 13 1016.56 21 14.15 1728 513 3.18 / 1121.59 2 2
5 13 455.36 21 14.40 977 295 3.48 / 1121.88 2 2
6 8 -0.04 165 14.64 302 730 4.21 / 1122.61 2 2
Average= 4.22
(KJ/cycle)

Cycle 264 GMT 24/10/2024 1:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 28 14.82 0 0 0.00 / 1114.18 2 2
2 7 2003.68 46 13.95 2924 1876 1.88 / 1116.06 2 2
3 13 1729.96 21 14.00 2628 773 2.65 / 1116.83 2 2
4 13 1140.92 21 14.14 1886 560 3.21 / 1117.39 2 2
5 13 409.76 21 14.48 913 278 3.49 / 1117.67 2 2
6 8 0.00 165 14.70 304 737 4.22 / 1118.40 2 2
Average= 4.22
(KJ/cycle)

Cycle 263 GMT 14/10/2024 1:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 28 14.85 0 0 0.00 / 1110.00 2 2
2 3 1020.12 1 15.16 0 0 0.00 / 1110.00 2 2
3 7 2010.48 46 13.95 2945 1890 1.89 / 1111.89 2 2
4 13 1615.64 21 14.04 2457 724 2.61 / 1112.61 2 2
5 13 1037.20 21 14.21 1743 520 3.13 / 1113.13 2 2
6 13 458.08 21 14.48 977 297 3.43 / 1113.43 2 2
7 8 0.00 165 14.73 308 749 4.18 / 1114.18 2 2
Average= 4.22
(KJ/cycle)

Cycle 262 GMT 4/10/2024 2:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 28 14.87 0 0 0.00 / 1105.80 2 2
2 7 2008.48 46 13.96 2919 1874 1.87 / 1107.68 2 2
3 13 1742.76 21 14.01 2626 773 2.65 / 1108.45 2 2
4 13 1032.88 21 14.23 1729 517 3.16 / 1108.96 2 2
5 13 446.88 21 14.51 961 293 3.46 / 1109.26 2 2
6 8 0.20 165 14.76 305 743 4.20 / 1110.00 2 2
Average= 4.22
(KJ/cycle)

Cycle 261 GMT 24/ 9/2024 2:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 28 14.89 0 0 0.00 / 1101.58 2 2
2 7 2005.88 46 13.95 2934 1883 1.88 / 1103.47 2 2
3 13 1749.52 21 14.00 2651 779 2.66 / 1104.25 2 2
4 13 1014.52 21 14.26 1715 514 3.18 / 1104.76 2 2
5 13 430.00 21 14.54 942 288 3.46 / 1105.05 2 2
6 8 0.08 165 14.77 309 753 4.22 / 1105.80 2 2
Average= 4.22
(KJ/cycle)

Cycle 260 GMT 14/ 9/2024 3:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 29 14.90 0 0 0.00 / 1097.33 2 2
2 3 971.00 -1 15.21 0 0 0.00 / 1097.33 2 2
3 7 2005.60 46 13.96 2922 1876 1.88 / 1099.21 2 2
4 13 1874.40 21 13.98 2800 822 2.70 / 1100.03 2 2
5 13 1014.24 21 14.27 1719 515 3.21 / 1100.54 2 2
6 13 450.16 21 14.54 971 296 3.51 / 1100.84 2 2
7 8 -0.04 165 14.79 305 744 4.25 / 1101.58 2 2
Average= 4.22
(KJ/cycle)

Cycle 259 GMT 4/ 9/2024 3:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 28 14.91 0 0 0.00 / 1093.02 2 2
2 3 1023.32 1 15.22 0 0 0.00 / 1093.02 2 2
3 7 2007.80 46 13.96 2928 1880 1.88 / 1094.90 2 2
4 13 1738.48 21 14.03 2623 773 2.65 / 1095.67 2 2
5 13 1293.88 21 14.14 2093 621 3.27 / 1096.30 2 2
6 13 415.44 21 14.57 921 282 3.56 / 1096.58 2 2
7 8 -0.24 165 14.80 308 752 4.31 / 1097.33 2 2
Average= 4.22
(KJ/cycle)

Cycle 258 GMT 25/ 8/2024 4:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 28 14.91 0 0 0.00 / 1088.81 2 2
2 7 2003.08 46 13.95 2941 1887 1.89 / 1090.70 2 2
3 13 1609.88 21 14.06 2481 733 2.62 / 1091.43 2 2
4 13 1055.92 21 14.25 1773 531 3.15 / 1091.96 2 2
5 13 479.00 21 14.53 1005 307 3.46 / 1092.27 2 2
6 8 0.16 165 14.80 308 752 4.21 / 1093.02 2 2
Average= 4.22
(KJ/cycle)

Cycle 257 GMT 15/ 8/2024 5: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 28 14.92 0 0 0.00 / 1084.70 2 2
2 7 2009.20 46 13.95 2933 1882 1.88 / 1086.58 2 2
3 13 1594.16 21 14.07 2461 727 2.61 / 1087.31 2 2
4 13 1022.24 21 14.28 1724 517 3.13 / 1087.83 2 2
5 13 329.56 21 14.64 800 246 3.37 / 1088.07 2 2
6 8 -0.08 165 14.82 302 738 4.11 / 1088.81 2 2
Average= 4.22
(KJ/cycle)

Cycle 256 GMT 5/ 8/2024 5:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 28 14.92 0 0 0.00 / 1080.49 2 2
2 7 2005.36 46 13.97 2928 1882 1.88 / 1082.37 2 2
3 13 1730.80 21 14.05 2597 766 2.65 / 1083.14 2 2
4 13 1020.36 21 14.28 1728 518 3.17 / 1083.65 2 2
5 13 462.00 21 14.56 984 301 3.47 / 1083.96 2 2
6 8 0.44 165 14.83 305 746 4.21 / 1084.70 2 2
Average= 4.22
(KJ/cycle)

Cycle 255 GMT 26/ 7/2024 6: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 29 14.92 0 0 0.00 / 1076.39 2 2
2 3 970.52 -1 15.23 0 0 0.00 / 1076.39 2 2
3 7 2006.24 46 13.97 2942 1891 1.89 / 1078.28 2 2
4 13 1597.72 21 14.10 2443 723 2.61 / 1079.00 2 2
5 13 904.64 21 14.35 1571 473 3.09 / 1079.47 2 2
6 13 362.28 21 14.63 848 261 3.35 / 1079.73 2 2
7 8 0.08 165 14.82 309 756 4.10 / 1080.49 2 2
Average= 4.22
(KJ/cycle)

Cycle 254 GMT 16/ 7/2024 6:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 28 14.93 0 0 0.00 / 1072.13 2 2
2 10 1012.92 3 15.19 0 0 0.00 / 1072.13 2 2
3 3 966.92 -1 15.22 0 0 0.00 / 1072.13 2 2
4 7 2005.44 46 14.00 2931 1888 1.89 / 1074.01 2 2
5 13 1610.28 21 14.11 2479 735 2.62 / 1074.75 2 2
6 13 1039.00 21 14.29 1742 523 3.14 / 1075.27 2 2
7 13 600.88 21 14.48 1167 355 3.50 / 1075.63 2 2
8 8 0.32 165 14.82 310 758 4.26 / 1076.39 2 2
Average= 4.22
(KJ/cycle)

Cycle 253 GMT 6/ 7/2024 7:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 29 14.91 0 0 0.00 / 1067.91 2 2
2 3 962.12 -1 15.23 0 0 0.00 / 1067.91 2 2
3 7 2009.00 46 14.03 2917 1883 1.88 / 1069.79 2 2
4 13 1739.84 21 14.09 2609 772 2.65 / 1070.57 2 2
5 13 1024.84 21 14.32 1721 518 3.17 / 1071.08 2 2
6 13 458.48 21 14.57 971 297 3.47 / 1071.38 2 2
7 8 0.28 165 14.82 305 746 4.22 / 1072.13 2 2
Average= 4.22
(KJ/cycle)

Cycle 252 GMT 26/ 6/2024 7:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 29 14.92 0 0 0.00 / 1063.75 2 2
2 7 2005.72 46 14.05 2906 1878 1.88 / 1065.63 2 2
3 13 1598.08 21 14.15 2457 730 2.61 / 1066.36 2 2
4 13 1033.84 21 14.31 1734 521 3.13 / 1066.88 2 2
5 13 452.32 21 14.58 963 295 3.42 / 1067.17 2 2
6 8 0.40 165 14.82 302 738 4.16 / 1067.91 2 2
Average= 4.22
(KJ/cycle)

Cycle 251 GMT 16/ 6/2024 8:33:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 29 14.91 0 0 0.00 / 1059.59 2 2
2 7 2007.68 47 14.06 2919 1929 1.93 / 1061.52 2 2
3 13 1485.56 21 14.18 2325 692 2.62 / 1062.21 2 2
4 13 1072.96 21 14.30 1792 538 3.16 / 1062.75 2 2
5 13 353.60 21 14.64 833 256 3.42 / 1063.00 2 2
6 8 0.16 165 14.82 305 746 4.16 / 1063.75 2 2
Average= 4.22
(KJ/cycle)

Cycle 250 GMT 6/ 6/2024 8:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 29 14.90 0 0 0.00 / 1055.40 2 2
2 7 2008.40 46 14.07 2917 1888 1.89 / 1057.29 2 2
3 13 1593.24 21 14.16 2460 732 2.62 / 1058.02 2 2
4 13 1021.32 21 14.33 1729 520 3.14 / 1058.54 2 2
5 13 432.32 21 14.59 943 289 3.43 / 1058.83 2 2
6 8 0.00 165 14.81 309 755 4.18 / 1059.59 2 2
Average= 4.22
(KJ/cycle)

Cycle 249 GMT 27/ 5/2024 9:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 28 14.90 0 0 0.00 / 1050.97 2 2
2 3 1028.24 1 15.24 0 0 0.00 / 1050.97 2 2
3 7 2005.32 46 14.08 2933 1900 1.90 / 1052.87 2 2
4 13 1733.56 21 14.14 2605 774 2.67 / 1053.64 2 2
5 13 1144.24 21 14.29 1864 559 3.23 / 1054.20 2 2
6 13 545.04 21 14.53 1094 334 3.57 / 1054.54 2 2
7 13 52.44 21 14.81 383 119 3.69 / 1054.65 2 2
8 8 -0.04 165 14.80 307 750 4.44 / 1055.40 2 2
Average= 4.22
(KJ/cycle)

Cycle 248 GMT 17/ 5/2024 10:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 29 14.90 0 0 0.00 / 1046.65 2 2
2 3 966.28 -1 15.25 0 0 0.00 / 1046.65 2 2
3 7 2004.84 46 14.10 2909 1887 1.89 / 1048.53 2 2
4 13 1599.04 21 14.17 2455 731 2.62 / 1049.27 2 2
5 13 1039.44 21 14.32 1748 526 3.14 / 1049.79 2 2
6 13 455.92 21 14.57 974 298 3.44 / 1050.09 2 2
7 13 70.40 21 14.80 412 128 3.57 / 1050.22 2 2
8 8 0.12 165 14.80 308 752 4.32 / 1050.97 2 2
Average= 4.22
(KJ/cycle)

Cycle 247 GMT 7/ 5/2024 10:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 29 14.91 0 0 0.00 / 1042.34 2 2
2 7 2004.72 46 14.08 2919 1891 1.89 / 1044.23 2 2
3 13 1741.56 21 14.14 2615 776 2.67 / 1045.01 2 2
4 13 1033.88 21 14.33 1738 523 3.19 / 1045.53 2 2
5 13 332.44 21 14.64 804 247 3.44 / 1045.78 2 2
6 13 40.52 21 14.82 364 113 3.55 / 1045.89 2 2
7 8 0.08 165 14.80 309 755 4.31 / 1046.65 2 2
Average= 4.22
(KJ/cycle)

Cycle 246 GMT 27/ 4/2024 11: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 29 14.91 0 0 0.00 / 1037.87 2 2
2 7 2005.76 46 14.09 2924 1895 1.90 / 1039.77 2 2
3 13 1878.16 21 14.10 2817 834 2.73 / 1040.60 2 2
4 13 1262.76 21 14.24 2028 606 3.34 / 1041.21 2 2
5 13 381.40 21 14.62 871 267 3.60 / 1041.48 2 2
6 13 53.84 21 14.82 383 119 3.72 / 1041.60 2 2
7 8 0.44 165 14.81 306 748 4.47 / 1042.34 2 2
Average= 4.22
(KJ/cycle)

Cycle 245 GMT 17/ 4/2024 11:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 29 14.93 0 0 0.00 / 1033.49 2 2
2 7 2006.68 46 14.10 2921 1895 1.89 / 1035.38 2 2
3 13 1875.16 21 14.12 2802 831 2.73 / 1036.21 2 2
4 13 1013.44 21 14.35 1711 516 3.24 / 1036.73 2 2
5 13 439.96 21 14.59 949 291 3.53 / 1037.02 2 2
6 13 32.72 21 14.83 345 107 3.64 / 1037.13 2 2
7 8 0.24 165 14.81 305 745 4.38 / 1037.87 2 2
Average= 4.22
(KJ/cycle)

Cycle 244 GMT 7/ 4/2024 12: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 29 14.92 0 0 0.00 / 1029.31 2 2
2 7 2005.04 46 14.10 2939 1906 1.91 / 1031.21 2 2
3 13 1734.80 21 14.17 2595 772 2.68 / 1031.98 2 2
4 13 1022.44 21 14.35 1718 518 3.20 / 1032.50 2 2
5 13 337.88 21 14.66 810 249 3.45 / 1032.75 2 2
6 8 0.36 165 14.83 301 737 4.18 / 1033.49 2 2
Average= 4.22
(KJ/cycle)

Cycle 243 GMT 28/ 3/2024 12:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 29 14.92 0 0 0.00 / 1025.03 2 2
2 7 2002.04 47 14.11 2917 1934 1.93 / 1026.96 2 2
3 13 1590.92 21 14.20 2439 727 2.66 / 1027.69 2 2
4 13 1027.76 21 14.34 1730 521 3.18 / 1028.21 2 2
5 13 325.64 21 14.67 793 244 3.43 / 1028.46 2 2
6 13 33.32 21 14.84 348 108 3.54 / 1028.57 2 2
7 8 -0.04 165 14.82 303 741 4.28 / 1029.31 2 2
Average= 4.22
(KJ/cycle)

Cycle 242 GMT 18/ 3/2024 12:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 29 14.93 0 0 0.00 / 1020.72 2 2
2 7 2009.12 46 14.10 2944 1909 1.91 / 1022.63 2 2
3 13 1599.44 21 14.20 2443 729 2.64 / 1023.36 2 2
4 13 1034.20 21 14.34 1739 524 3.16 / 1023.88 2 2
5 13 459.68 21 14.59 974 298 3.46 / 1024.18 2 2
6 13 38.08 21 14.84 357 111 3.57 / 1024.29 2 2
7 8 0.00 165 14.82 303 741 4.31 / 1025.03 2 2
Average= 4.22
(KJ/cycle)

Cycle 241 GMT 8/ 3/2024 13:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 29 14.93 0 0 0.00 / 1016.38 2 2
2 7 2005.16 46 14.11 2940 1908 1.91 / 1018.29 2 2
3 13 1739.96 21 14.17 2613 778 2.69 / 1019.07 2 2
4 13 1005.64 21 14.36 1702 513 3.20 / 1019.58 2 2
5 13 435.80 21 14.61 947 291 3.49 / 1019.87 2 2
6 13 30.16 21 14.85 342 107 3.60 / 1019.98 2 2
7 8 0.40 165 14.82 302 738 4.33 / 1020.72 2 2
Average= 4.22
(KJ/cycle)

Cycle 240 GMT 27/ 2/2024 14: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 29 14.94 0 0 0.00 / 1012.06 2 2
2 7 2004.04 46 14.11 2930 1902 1.90 / 1013.96 2 2
3 13 1605.16 21 14.19 2467 735 2.64 / 1014.69 2 2
4 13 1156.72 21 14.30 1902 571 3.21 / 1015.26 2 2
5 13 402.56 21 14.63 900 277 3.48 / 1015.54 2 2
6 13 24.60 21 14.86 334 104 3.59 / 1015.64 2 2
7 8 0.08 165 14.83 302 739 4.33 / 1016.38 2 2
Average= 4.22
(KJ/cycle)

Cycle 239 GMT 17/ 2/2024 14:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 29 14.94 0 0 0.00 / 1007.61 2 2
2 7 2007.28 47 14.11 2940 1950 1.95 / 1009.56 2 2
3 13 1876.24 21 14.14 2790 828 2.78 / 1010.39 2 2
4 13 1024.52 21 14.36 1734 523 3.30 / 1010.92 2 2
5 13 459.28 21 14.60 977 300 3.60 / 1011.22 2 2
6 13 18.24 21 14.87 322 101 3.70 / 1011.32 2 2
7 8 0.20 165 14.84 302 739 4.44 / 1012.06 2 2
Average= 4.22
(KJ/cycle)

Cycle 238 GMT 7/ 2/2024 15: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 29 14.94 0 0 0.00 / 1003.38 2 2
2 7 2010.08 46 14.11 2943 1910 1.91 / 1005.29 2 2
3 13 1594.36 21 14.19 2464 734 2.64 / 1006.02 2 2
4 13 1145.68 21 14.31 1885 566 3.21 / 1006.59 2 2
5 13 425.00 21 14.62 932 286 3.50 / 1006.87 2 2
6 8 0.12 165 14.84 303 742 4.24 / 1007.61 2 2
Average= 4.22
(KJ/cycle)

Cycle 237 GMT 28/ 1/2024 15:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 29 14.95 0 0 0.00 / 999.11 2 2
2 7 2005.96 46 14.11 2918 1894 1.89 / 1001.01 2 2
3 13 1742.60 21 14.17 2650 789 2.68 / 1001.80 2 2
4 13 878.20 21 14.43 1537 466 3.15 / 1002.26 2 2
5 13 341.28 21 14.68 818 252 3.40 / 1002.51 2 2
6 13 46.36 21 14.86 368 115 3.52 / 1002.63 2 2
7 8 0.24 165 14.84 305 747 4.26 / 1003.38 2 2
Average= 4.22
(KJ/cycle)

Cycle 236 GMT 18/ 1/2024 16: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 29 14.95 0 0 0.00 / 994.95 2 2
2 7 2006.52 46 14.11 2941 1909 1.91 / 996.86 2 2
3 13 1600.16 21 14.19 2469 736 2.64 / 997.59 2 2
4 13 899.20 21 14.42 1562 473 3.12 / 998.07 2 2
5 13 472.76 21 14.60 998 306 3.42 / 998.37 2 2
6 8 0.16 165 14.85 303 742 4.17 / 999.11 2 2
Average= 4.22
(KJ/cycle)

Cycle 235 GMT 8/ 1/2024 16:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 29 14.95 0 0 0.00 / 990.56 2 2
2 7 2002.32 47 14.11 2929 1942 1.94 / 992.51 2 2
3 13 1715.04 21 14.18 2591 772 2.71 / 993.28 2 2
4 13 1004.64 21 14.38 1704 515 3.23 / 993.79 2 2
5 13 428.16 21 14.63 945 290 3.52 / 994.08 2 2
6 13 63.44 21 14.85 400 125 3.64 / 994.21 2 2
7 8 0.00 165 14.85 302 740 4.38 / 994.95 2 2
Average= 4.22
(KJ/cycle)

Cycle 234 GMT 29/12/2023 16:55:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 29 14.96 0 0 0.00 / 986.25 2 2
2 7 2007.48 46 14.11 2948 1913 1.91 / 988.16 2 2
3 13 1753.44 21 14.17 2637 785 2.70 / 988.95 2 2
4 13 1021.44 21 14.37 1728 521 3.22 / 989.47 2 2
5 13 577.04 21 14.55 1141 349 3.57 / 989.82 2 2
6 8 -0.12 165 14.86 304 745 4.31 / 990.56 2 2
Average= 4.22
(KJ/cycle)

Cycle 233 GMT 19/12/2023 17:30: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 29 14.95 0 0 0.00 / 981.95 2 2
2 7 2003.44 46 14.12 2929 1902 1.90 / 983.85 2 2
3 13 1741.72 21 14.17 2616 778 2.68 / 984.63 2 2
4 13 1035.00 21 14.37 1746 527 3.21 / 985.16 2 2
5 13 603.60 21 14.54 1173 358 3.57 / 985.51 2 2
6 8 0.08 165 14.86 300 736 4.30 / 986.25 2 2
Average= 4.21
(KJ/cycle)

Cycle 232 GMT 9/12/2023 18: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 28 14.97 0 0 0.00 / 977.50 2 2
2 7 2006.28 47 14.11 2935 1946 1.95 / 979.45 2 2
3 13 1731.32 21 14.17 2623 781 2.73 / 980.23 2 2
4 13 1155.12 21 14.32 1904 573 3.30 / 980.80 2 2
5 13 416.96 21 14.65 925 285 3.58 / 981.09 2 2
6 13 55.84 21 14.87 383 120 3.70 / 981.21 2 2
7 8 -0.24 165 14.86 303 743 4.45 / 981.95 2 2
Average= 4.21
(KJ/cycle)

Cycle 231 GMT 29/11/2023 18:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 28 14.97 0 0 0.00 / 973.39 2 2
2 7 2003.52 46 14.12 2930 1903 1.90 / 975.29 2 2
3 13 1596.36 21 14.21 2459 734 2.64 / 976.02 2 2
4 13 910.32 21 14.42 1585 480 3.12 / 976.50 2 2
5 13 366.28 21 14.68 855 264 3.38 / 976.77 2 2
6 8 0.12 165 14.88 300 737 4.12 / 977.50 2 2
Average= 4.21
(KJ/cycle)

Cycle 230 GMT 19/11/2023 19: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 28 14.97 0 0 0.00 / 969.16 2 2
2 7 2005.00 46 14.12 2924 1899 1.90 / 971.06 2 2
3 13 1726.76 21 14.18 2630 783 2.68 / 971.84 2 2
4 13 1003.80 21 14.38 1702 514 3.20 / 972.36 2 2
5 13 432.04 21 14.64 940 289 3.49 / 972.65 2 2
6 8 0.24 165 14.88 301 739 4.22 / 973.39 2 2
Average= 4.21
(KJ/cycle)

Cycle 229 GMT 9/11/2023 19:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 28 14.97 0 0 0.00 / 964.96 2 2
2 7 2003.32 46 14.12 2928 1902 1.90 / 966.86 2 2
3 13 1593.68 21 14.21 2460 734 2.64 / 967.60 2 2
4 13 1011.76 21 14.38 1721 520 3.16 / 968.12 2 2
5 13 439.24 21 14.63 960 295 3.45 / 968.41 2 2
6 8 0.28 165 14.87 305 748 4.20 / 969.16 2 2
Average= 4.21
(KJ/cycle)

Cycle 228 GMT 30/10/2023 20:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 28 14.98 0 0 0.00 / 960.80 2 2
2 7 2005.16 46 14.12 2928 1902 1.90 / 962.70 2 2
3 13 1600.32 21 14.20 2483 740 2.64 / 963.44 2 2
4 13 1023.76 21 14.37 1733 523 3.17 / 963.97 2 2
5 13 317.08 21 14.72 788 244 3.41 / 964.21 2 2
6 8 0.28 165 14.87 306 751 4.16 / 964.96 2 2
Average= 4.21
(KJ/cycle)

Cycle 227 GMT 20/10/2023 20:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 28 14.99 0 0 0.00 / 956.50 2 2
2 7 2005.80 46 14.12 2946 1913 1.91 / 958.42 2 2
3 13 1874.88 21 14.14 2803 832 2.75 / 959.25 2 2
4 13 994.16 21 14.39 1696 513 3.26 / 959.76 2 2
5 13 427.84 21 14.65 938 289 3.55 / 960.05 2 2
6 8 -0.04 165 14.88 307 754 4.30 / 960.80 2 2
Average= 4.21
(KJ/cycle)

Cycle 226 GMT 10/10/2023 21:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 28 14.99 0 0 0.00 / 952.21 2 2
2 7 2006.04 46 14.12 2916 1894 1.89 / 954.11 2 2
3 13 1726.92 21 14.17 2624 781 2.67 / 954.89 2 2
4 13 1141.44 21 14.32 1894 570 3.24 / 955.46 2 2
5 13 418.52 21 14.66 927 285 3.53 / 955.74 2 2
6 8 0.16 165 14.88 309 759 4.29 / 956.50 2 2
Average= 4.21
(KJ/cycle)

Cycle 225 GMT 30/ 9/2023 21:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 28 15.00 0 0 0.00 / 948.11 2 2
2 7 2005.44 46 14.10 2955 1917 1.92 / 950.02 2 2
3 13 1477.60 21 14.24 2329 696 2.61 / 950.72 2 2
4 13 914.80 21 14.42 1591 482 3.09 / 951.20 2 2
5 13 359.88 21 14.69 849 262 3.36 / 951.46 2 2
6 8 0.00 165 14.88 305 749 4.11 / 952.21 2 2
Average= 4.21
(KJ/cycle)

Cycle 224 GMT 20/ 9/2023 22:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 28 15.00 0 0 0.00 / 943.81 2 2
2 7 2003.00 46 14.11 2934 1904 1.90 / 945.71 2 2
3 13 1739.28 21 14.17 2624 781 2.69 / 946.49 2 2
4 13 1163.56 21 14.32 1916 576 3.26 / 947.07 2 2
5 13 435.72 21 14.65 952 293 3.55 / 947.36 2 2
6 8 0.00 165 14.90 304 747 4.30 / 948.11 2 2
Average= 4.21
(KJ/cycle)

Cycle 223 GMT 10/ 9/2023 23: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 28 15.00 0 0 0.00 / 939.55 2 2
2 7 2007.12 46 14.11 2923 1897 1.90 / 941.45 2 2
3 13 1740.48 21 14.16 2639 785 2.68 / 942.24 2 2
4 13 1009.00 21 14.38 1723 520 3.20 / 942.76 2 2
5 13 443.56 21 14.65 964 297 3.50 / 943.05 2 2
6 8 0.12 165 14.90 306 752 4.25 / 943.81 2 2
Average= 4.21
(KJ/cycle)

Cycle 222 GMT 31/ 8/2023 23:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 28 15.00 0 0 0.00 / 935.25 2 2
2 3 1023.28 1 15.30 0 0 0.00 / 935.25 2 2
3 7 2009.60 46 14.10 2940 1907 1.91 / 937.16 2 2
4 13 1732.76 21 14.16 2619 779 2.69 / 937.94 2 2
5 13 1155.72 21 14.32 1904 573 3.26 / 938.51 2 2
6 13 424.72 21 14.66 936 288 3.55 / 938.80 2 2
7 8 0.12 165 14.90 308 757 4.30 / 939.55 2 2
Average= 4.21
(KJ/cycle)

Cycle 221 GMT 22/ 8/2023 0:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 27 15.01 0 0 0.00 / 930.76 2 2
2 3 1026.20 1 15.30 0 0 0.00 / 930.76 2 2
3 7 2007.88 46 14.09 2936 1903 1.90 / 932.66 2 2
4 13 1594.84 21 14.20 2470 737 2.64 / 933.40 2 2
5 13 1027.28 21 14.37 1722 520 3.16 / 933.92 2 2
6 13 325.72 21 14.73 795 246 3.41 / 934.16 2 2
7 8 0.04 165 14.91 305 750 4.16 / 934.91 2 2
8 14 0.04 75 14.87 303 338 4.49 / 935.25 2 2
Average= 4.21
(KJ/cycle)

Cycle 220 GMT 12/ 8/2023 0:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 28 15.00 0 0 0.00 / 926.42 2 2
2 3 970.08 -1 15.30 0 0 0.00 / 926.42 2 2
3 7 2007.08 47 14.10 2932 1943 1.94 / 928.37 2 2
4 13 1734.32 21 14.16 2633 783 2.73 / 929.15 2 2
5 13 1159.08 21 14.32 1907 573 3.30 / 929.72 2 2
6 13 428.92 21 14.67 937 289 3.59 / 930.01 2 2
7 8 0.12 165 14.91 303 745 4.33 / 930.76 2 2
Average= 4.21
(KJ/cycle)

Cycle 219 GMT 2/ 8/2023 1:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 28 15.02 0 0 0.00 / 922.30 2 2
2 7 2004.20 46 14.09 2938 1904 1.90 / 924.20 2 2
3 13 1472.40 21 14.23 2294 686 2.59 / 924.89 2 2
4 13 1055.64 21 14.35 1772 534 3.12 / 925.42 2 2
5 13 350.48 21 14.72 833 257 3.38 / 925.68 2 2
6 8 0.40 165 14.91 302 743 4.12 / 926.42 2 2
Average= 4.21
(KJ/cycle)

Cycle 218 GMT 23/ 7/2023 1:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 28 15.01 0 0 0.00 / 918.15 2 2
2 7 2005.72 46 14.10 2933 1902 1.90 / 920.06 2 2
3 13 1597.36 21 14.20 2462 734 2.64 / 920.79 2 2
4 13 1032.68 21 14.37 1733 523 3.16 / 921.31 2 2
5 13 327.28 21 14.74 798 247 3.41 / 921.56 2 2
6 8 0.04 165 14.92 301 741 4.15 / 922.30 2 2
Average= 4.21
(KJ/cycle)

Cycle 217 GMT 13/ 7/2023 2: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 28 15.01 0 0 0.00 / 913.94 2 2
2 7 2004.64 46 14.09 2930 1899 1.90 / 915.83 2 2
3 13 1734.04 21 14.15 2624 780 2.68 / 916.61 2 2
4 13 1006.88 21 14.39 1696 513 3.19 / 917.13 2 2
5 13 422.68 21 14.68 926 285 3.48 / 917.41 2 2
6 8 0.12 165 14.91 301 741 4.22 / 918.15 2 2
Average= 4.21
(KJ/cycle)

Cycle 216 GMT 3/ 7/2023 2:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 28 15.02 0 0 0.00 / 909.77 2 2
2 7 2002.96 46 14.10 2904 1884 1.88 / 911.66 2 2
3 13 1594.80 21 14.19 2432 725 2.61 / 912.38 2 2
4 13 1024.72 21 14.38 1723 520 3.13 / 912.90 2 2
5 13 446.48 21 14.66 957 295 3.42 / 913.20 2 2
6 8 0.12 165 14.91 300 738 4.16 / 913.94 2 2
Average= 4.21
(KJ/cycle)

Cycle 215 GMT 23/ 6/2023 3:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 29 15.01 0 0 0.00 / 905.65 2 2
2 7 2002.88 46 14.10 2909 1887 1.89 / 907.54 2 2
3 13 1585.68 21 14.20 2448 730 2.62 / 908.27 2 2
4 13 1029.76 21 14.38 1737 525 3.14 / 908.79 2 2
5 13 336.84 21 14.73 808 250 3.39 / 909.04 2 2
6 8 0.04 165 14.92 298 734 4.12 / 909.77 2 2
Average= 4.21
(KJ/cycle)

Cycle 214 GMT 13/ 6/2023 3:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 29 15.01 0 0 0.00 / 901.44 2 2
2 7 2007.76 46 14.09 2937 1904 1.90 / 903.35 2 2
3 13 1598.36 21 14.19 2450 730 2.63 / 904.08 2 2
4 13 1041.16 21 14.37 1748 527 3.16 / 904.60 2 2
5 13 451.64 21 14.65 970 298 3.46 / 904.90 2 2
6 8 0.28 165 14.91 304 748 4.21 / 905.65 2 2
Average= 4.21
(KJ/cycle)

Cycle 213 GMT 3/ 6/2023 4: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 29 15.01 0 0 0.00 / 897.14 2 2
2 7 2006.16 46 14.09 2926 1896 1.90 / 899.04 2 2
3 13 1604.72 21 14.18 2463 733 2.63 / 899.77 2 2
4 13 1027.44 21 14.38 1731 523 3.15 / 900.29 2 2
5 13 446.08 21 14.66 960 296 3.45 / 900.59 2 2
6 13 37.52 21 14.92 352 110 3.56 / 900.70 2 2
7 8 -0.04 165 14.90 303 745 4.30 / 901.44 2 2
Average= 4.21
(KJ/cycle)

Cycle 212 GMT 24/ 5/2023 4:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 29 15.02 0 0 0.00 / 892.82 2 2
2 7 2005.80 46 14.09 2939 1905 1.90 / 894.73 2 2
3 13 1578.92 21 14.19 2441 727 2.63 / 895.46 2 2
4 13 1014.12 21 14.38 1713 517 3.15 / 895.97 2 2
5 13 445.76 21 14.66 964 297 3.45 / 896.27 2 2
6 13 67.04 21 14.90 397 124 3.57 / 896.39 2 2
7 8 0.24 165 14.90 303 745 4.32 / 897.14 2 2
Average= 4.21
(KJ/cycle)

Cycle 211 GMT 14/ 5/2023 5: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 29 15.01 0 0 0.00 / 888.52 2 2
2 7 2009.56 46 14.09 2925 1896 1.90 / 890.41 2 2
3 13 1744.40 21 14.14 2655 788 2.68 / 891.20 2 2
4 13 1022.68 21 14.38 1717 518 3.20 / 891.72 2 2
5 13 329.32 21 14.74 804 249 3.45 / 891.97 2 2
6 13 43.48 21 14.92 361 113 3.56 / 892.08 2 2
7 8 0.20 165 14.91 301 741 4.31 / 892.82 2 2
Average= 4.21
(KJ/cycle)

Cycle 210 GMT 4/ 5/2023 5:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 29 15.03 0 0 0.00 / 884.07 2 2
2 7 2008.20 47 14.08 2945 1949 1.95 / 886.02 2 2
3 13 1599.44 21 14.19 2462 734 2.68 / 886.76 2 2
4 13 1163.68 21 14.32 1905 573 3.26 / 887.33 2 2
5 13 553.88 21 14.60 1105 339 3.59 / 887.67 2 2
6 13 28.20 21 14.93 341 107 3.70 / 887.78 2 2
7 8 0.28 165 14.90 302 742 4.44 / 888.52 2 2
Average= 4.21
(KJ/cycle)

Cycle 209 GMT 24/ 4/2023 5:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 29 15.02 0 0 0.00 / 879.74 2 2
2 7 2004.24 46 14.09 2929 1898 1.90 / 881.64 2 2
3 13 1743.84 21 14.15 2620 779 2.68 / 882.42 2 2
4 13 1023.80 21 14.39 1725 521 3.20 / 882.94 2 2
5 13 452.68 21 14.66 971 299 3.50 / 883.24 2 2
6 13 36.24 21 14.93 347 109 3.61 / 883.35 2 2
7 8 0.12 165 14.91 296 728 4.33 / 884.07 2 2
Average= 4.21
(KJ/cycle)

Cycle 208 GMT 14/ 4/2023 6:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 30 15.02 0 0 0.00 / 875.42 2 2
2 7 2009.00 46 14.09 2944 1908 1.91 / 877.33 2 2
3 13 1612.20 21 14.18 2479 738 2.65 / 878.07 2 2
4 13 1043.44 21 14.37 1750 528 3.17 / 878.60 2 2
5 13 468.28 21 14.65 985 303 3.48 / 878.90 2 2
6 13 22.00 21 14.94 326 102 3.58 / 879.00 2 2
7 8 0.24 165 14.92 299 736 4.32 / 879.74 2 2
Average= 4.21
(KJ/cycle)

Cycle 207 GMT 4/ 4/2023 6:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 30 15.03 0 0 0.00 / 871.12 2 2
2 7 2010.40 46 14.09 2938 1904 1.90 / 873.02 2 2
3 13 1614.56 21 14.19 2475 738 2.64 / 873.76 2 2
4 13 1058.24 21 14.37 1751 528 3.17 / 874.29 2 2
5 13 478.04 21 14.65 992 305 3.48 / 874.59 2 2
6 13 40.56 21 14.93 350 110 3.59 / 874.70 2 2
7 8 0.16 165 14.91 293 721 4.31 / 875.42 2 2
Average= 4.21
(KJ/cycle)

Cycle 206 GMT 25/ 3/2023 7:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 29 15.03 0 0 0.00 / 866.71 2 2
2 7 2006.12 46 14.08 2947 1909 1.91 / 868.62 2 2
3 13 1733.68 21 14.15 2614 777 2.69 / 869.39 2 2
4 13 1285.28 21 14.27 2052 615 3.30 / 870.01 2 2
5 13 396.72 21 14.70 880 272 3.57 / 870.28 2 2
6 13 54.08 21 14.93 371 116 3.69 / 870.39 2 2
7 8 0.28 165 14.92 294 724 4.41 / 871.12 2 2
Average= 4.21
(KJ/cycle)

Cycle 205 GMT 15/ 3/2023 7:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 29 15.02 0 0 0.00 / 862.35 2 2
2 7 2005.68 47 14.09 2920 1934 1.93 / 864.28 2 2
3 13 1735.72 21 14.15 2618 778 2.71 / 865.06 2 2
4 13 1016.48 21 14.39 1713 518 3.23 / 865.58 2 2
5 13 444.56 21 14.67 952 293 3.52 / 865.87 2 2
6 13 37.20 21 14.94 348 109 3.63 / 865.98 2 2
7 8 0.24 165 14.92 296 729 4.36 / 866.71 2 2
Average= 4.21
(KJ/cycle)

Cycle 204 GMT 5/ 3/2023 8: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 28 15.02 0 0 0.00 / 858.04 2 2
2 3 1049.20 1 15.31 0 0 0.00 / 858.04 2 2
3 7 2004.52 47 14.09 2942 1948 1.95 / 859.99 2 2
4 13 1605.52 21 14.20 2459 733 2.68 / 860.72 2 2
5 13 906.56 21 14.44 1556 472 3.15 / 861.19 2 2
6 13 481.04 21 14.65 1000 308 3.46 / 861.50 2 2
7 13 38.28 21 14.93 353 111 3.57 / 861.61 2 2
8 8 -0.08 165 14.92 299 736 4.31 / 862.35 2 2
Average= 4.21
(KJ/cycle)

Cycle 203 GMT 23/ 2/2023 8:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 29 15.02 0 0 0.00 / 853.76 2 2
2 3 972.40 -1 15.31 0 0 0.00 / 853.76 2 2
3 7 2010.68 47 14.10 2913 1930 1.93 / 855.69 2 2
4 13 1600.76 21 14.20 2465 735 2.67 / 856.43 2 2
5 13 1020.20 21 14.39 1718 519 3.18 / 856.95 2 2
6 13 333.72 21 14.75 798 247 3.43 / 857.19 2 2
7 13 41.96 21 14.93 353 111 3.54 / 857.30 2 2
8 8 0.24 165 14.92 298 734 4.28 / 858.04 2 2
Average= 4.21
(KJ/cycle)

Cycle 202 GMT 13/ 2/2023 9:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 29 15.02 0 0 0.00 / 849.57 2 2
2 7 2004.20 46 14.10 2911 1888 1.89 / 851.46 2 2
3 13 1600.40 21 14.20 2450 731 2.62 / 852.19 2 2
4 13 924.48 21 14.44 1589 482 3.10 / 852.67 2 2
5 13 345.00 21 14.73 818 253 3.35 / 852.92 2 2
6 13 43.04 21 14.93 358 112 3.47 / 853.03 2 2
7 8 0.28 165 14.91 296 728 4.19 / 853.76 2 2
Average= 4.21
(KJ/cycle)

Cycle 201 GMT 3/ 2/2023 9:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 29 15.02 0 0 0.00 / 845.23 2 2
2 7 2003.48 46 14.09 2924 1895 1.90 / 847.13 2 2
3 13 1742.36 21 14.15 2623 779 2.67 / 847.91 2 2
4 13 1006.48 21 14.40 1700 514 3.19 / 848.42 2 2
5 13 434.28 21 14.67 944 291 3.48 / 848.71 2 2
6 13 64.32 21 14.91 391 122 3.60 / 848.84 2 2
7 8 0.24 165 14.92 297 731 4.33 / 849.57 2 2
Average= 4.21
(KJ/cycle)

Cycle 200 GMT 24/ 1/2023 9:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 29 15.03 0 0 0.00 / 841.07 2 2
2 7 2005.24 46 14.09 2926 1896 1.90 / 842.97 2 2
3 13 1464.52 21 14.23 2292 685 2.58 / 843.65 2 2
4 13 916.44 21 14.44 1583 480 3.06 / 844.13 2 2
5 13 375.84 21 14.71 858 265 3.33 / 844.40 2 2
6 13 28.44 21 14.94 336 105 3.43 / 844.50 2 2
7 8 0.00 165 14.92 298 734 4.17 / 845.23 2 2
Average= 4.21
(KJ/cycle)

Cycle 199 GMT 14/ 1/2023 9:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 29 15.04 0 0 0.00 / 836.73 2 2
2 7 2005.40 46 14.10 2932 1902 1.90 / 838.63 2 2
3 13 1741.60 21 14.17 2619 779 2.68 / 839.41 2 2
4 13 1031.52 21 14.39 1735 524 3.21 / 839.94 2 2
5 13 447.20 21 14.67 958 295 3.50 / 840.23 2 2
6 13 38.64 21 14.94 349 109 3.61 / 840.34 2 2
7 8 -0.36 165 14.92 296 729 4.34 / 841.07 2 2
Average= 4.21
(KJ/cycle)

Cycle 198 GMT 4/ 1/2023 9:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 28 15.03 0 0 0.00 / 832.51 2 2
2 3 1039.04 1 15.32 0 0 0.00 / 832.51 2 2
3 7 2002.08 47 14.11 2900 1923 1.92 / 834.43 2 2
4 13 1592.28 21 14.21 2435 727 2.65 / 835.16 2 2
5 13 918.40 21 14.45 1580 479 3.13 / 835.64 2 2
6 13 364.28 21 14.73 838 259 3.39 / 835.90 2 2
7 13 23.36 21 14.95 327 103 3.49 / 836.00 2 2
8 8 0.00 165 14.93 296 729 4.22 / 836.73 2 2
Average= 4.20
(KJ/cycle)

Cycle 197 GMT 25/12/2022 10:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 29 15.02 0 0 0.00 / 828.19 2 2
2 3 971.04 -1 15.31 0 0 0.00 / 828.19 2 2
3 7 2004.28 47 14.11 2918 1935 1.94 / 830.12 2 2
4 13 1596.96 21 14.21 2456 733 2.67 / 830.86 2 2
5 13 1029.52 21 14.39 1735 524 3.19 / 831.38 2 2
6 13 436.56 21 14.68 940 290 3.48 / 831.67 2 2
7 13 31.80 21 14.94 341 107 3.59 / 831.78 2 2
8 8 0.24 165 14.92 298 734 4.32 / 832.51 2 2
Average= 4.20
(KJ/cycle)

Cycle 196 GMT 15/12/2022 10:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 29 15.04 0 0 0.00 / 823.94 2 2
2 7 2005.04 46 14.11 2929 1901 1.90 / 825.84 2 2
3 13 1468.04 21 14.25 2303 689 2.59 / 826.53 2 2
4 13 1044.60 21 14.39 1744 527 3.12 / 827.05 2 2
5 13 454.40 21 14.67 964 297 3.41 / 827.35 2 2
6 13 32.68 21 14.94 342 107 3.52 / 827.46 2 2
7 8 -0.20 165 14.91 297 731 4.25 / 828.19 2 2
Average= 4.20
(KJ/cycle)

Cycle 195 GMT 5/12/2022 11:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 29 15.04 0 0 0.00 / 819.84 2 2
2 7 2002.68 46 14.12 2904 1886 1.89 / 821.73 2 2
3 13 1589.60 21 14.22 2433 727 2.61 / 822.46 2 2
4 13 1021.08 21 14.40 1709 517 3.13 / 822.97 2 2
5 13 326.24 21 14.76 780 242 3.37 / 823.22 2 2
6 8 0.20 165 14.94 292 720 4.09 / 823.94 2 2
Average= 4.20
(KJ/cycle)

Cycle 194 GMT 25/11/2022 11:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 28 15.03 0 0 0.00 / 815.74 2 2
2 7 2006.80 46 14.12 2921 1897 1.90 / 817.63 2 2
3 13 1599.12 21 14.22 2436 727 2.62 / 818.36 2 2
4 13 1020.28 21 14.40 1719 520 3.14 / 818.88 2 2
5 13 324.24 21 14.76 782 242 3.39 / 819.12 2 2
6 8 -0.20 165 14.94 293 722 4.11 / 819.84 2 2
Average= 4.20
(KJ/cycle)

Cycle 193 GMT 15/11/2022 11:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 28 15.02 0 0 0.00 / 811.60 2 2
2 7 2004.32 46 14.11 2942 1910 1.91 / 813.51 2 2
3 13 1596.12 21 14.21 2451 731 2.64 / 814.24 2 2
4 13 1021.20 21 14.40 1720 520 3.16 / 814.76 2 2
5 13 326.04 21 14.76 789 245 3.41 / 815.01 2 2
6 8 -0.08 165 14.93 296 729 4.13 / 815.74 2 2
Average= 4.20
(KJ/cycle)

Cycle 192 GMT 5/11/2022 12:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 27 15.02 0 0 0.00 / 807.27 2 2
2 3 1034.32 1 15.32 0 0 0.00 / 807.27 2 2
3 7 2007.88 46 14.13 2916 1895 1.90 / 809.17 2 2
4 13 1735.92 21 14.18 2608 777 2.67 / 809.94 2 2
5 13 1014.20 21 14.41 1709 517 3.19 / 810.46 2 2
6 13 450.60 21 14.67 960 296 3.48 / 810.76 2 2
7 13 35.24 21 14.94 344 108 3.59 / 810.86 2 2
8 8 0.04 165 14.92 299 736 4.33 / 811.60 2 2
Average= 4.21
(KJ/cycle)

Cycle 191 GMT 26/10/2022 12:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 28 15.02 0 0 0.00 / 803.13 2 2
2 3 968.76 -1 15.33 0 0 0.00 / 803.13 2 2
3 7 1983.12 46 14.13 2875 1869 1.87 / 804.99 2 2
4 13 1719.20 21 14.19 2577 768 2.64 / 805.76 2 2
5 13 885.56 21 14.46 1535 466 3.10 / 806.23 2 2
6 13 472.56 21 14.66 989 304 3.41 / 806.53 2 2
7 8 0.32 165 14.92 300 739 4.15 / 807.27 2 2
Average= 4.20
(KJ/cycle)

Cycle 190 GMT 16/10/2022 11:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 28 15.02 0 0 0.00 / 799.04 2 2
2 7 2009.80 46 14.13 2922 1899 1.90 / 800.94 2 2
3 13 1478.76 21 14.24 2307 690 2.59 / 801.63 2 2
4 13 945.04 21 14.43 1620 491 3.08 / 802.12 2 2
5 13 379.00 21 14.72 858 265 3.35 / 802.38 2 2
6 8 0.00 165 14.92 301 741 4.09 / 803.13 2 2
Average= 4.20
(KJ/cycle)

Cycle 189 GMT 6/10/2022 11:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 28 15.02 0 0 0.00 / 794.66 2 2
2 7 2003.60 46 14.13 2938 1910 1.91 / 796.56 2 2
3 13 1731.16 21 14.19 2602 775 2.69 / 797.34 2 2
4 13 1012.08 21 14.41 1707 517 3.20 / 797.86 2 2
5 13 578.96 21 14.60 1131 347 3.55 / 798.20 2 2
6 13 31.56 21 14.94 334 105 3.65 / 798.31 2 2
7 8 0.32 165 14.92 297 731 4.38 / 799.04 2 2
Average= 4.21
(KJ/cycle)

Cycle 188 GMT 26/ 9/2022 12:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 28 15.02 0 0 0.00 / 790.51 2 2
2 7 2005.32 46 14.13 2935 1908 1.91 / 792.42 2 2
3 13 1595.32 21 14.23 2438 729 2.64 / 793.15 2 2
4 13 1023.88 21 14.40 1721 520 3.16 / 793.67 2 2
5 13 331.44 21 14.75 795 246 3.40 / 793.92 2 2
6 8 0.28 165 14.92 300 739 4.14 / 794.66 2 2
Average= 4.20
(KJ/cycle)

Cycle 187 GMT 16/ 9/2022 12:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 28 15.03 0 0 0.00 / 786.43 2 2
2 3 1020.64 1 15.33 0 0 0.00 / 786.43 2 2
3 7 2007.40 46 14.14 2921 1900 1.90 / 788.33 2 2
4 13 1471.32 21 14.26 2303 690 2.59 / 789.02 2 2
5 13 940.96 21 14.44 1613 489 3.08 / 789.51 2 2
6 13 373.76 21 14.72 861 266 3.34 / 789.77 2 2
7 8 0.12 165 14.92 301 741 4.09 / 790.51 2 2
Average= 4.20
(KJ/cycle)

Cycle 186 GMT 6/ 9/2022 12:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 27 15.01 0 0 0.00 / 782.24 2 2
2 7 2005.12 46 14.14 2928 1904 1.90 / 784.15 2 2
3 13 1589.72 21 14.23 2445 731 2.64 / 784.88 2 2
4 13 1018.56 21 14.41 1724 522 3.16 / 785.40 2 2
5 13 430.36 21 14.68 931 287 3.44 / 785.69 2 2
6 8 0.20 165 14.92 301 741 4.18 / 786.43 2 2
Average= 4.21
(KJ/cycle)

Cycle 185 GMT 27/ 8/2022 13:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 28 15.01 0 0 0.00 / 777.98 2 2
2 3 968.32 -1 15.34 0 0 0.00 / 777.98 2 2
3 7 2007.84 46 14.14 2937 1910 1.91 / 779.89 2 2
4 13 1609.24 21 14.22 2467 737 2.65 / 780.63 2 2
5 13 1177.68 21 14.34 1928 581 3.23 / 781.21 2 2
6 13 452.48 21 14.67 967 298 3.53 / 781.50 2 2
7 8 0.12 165 14.92 300 739 4.26 / 782.24 2 2
Average= 4.21
(KJ/cycle)

Cycle 184 GMT 17/ 8/2022 13:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 29 15.02 0 0 0.00 / 773.63 2 2
2 7 2006.76 46 14.14 2933 1908 1.91 / 775.54 2 2
3 13 1740.96 21 14.20 2599 775 2.68 / 776.31 2 2
4 13 1023.12 21 14.41 1728 523 3.21 / 776.84 2 2
5 13 444.96 21 14.68 955 294 3.50 / 777.13 2 2
6 13 40.76 21 14.93 355 111 3.61 / 777.24 2 2
7 8 0.20 165 14.91 300 738 4.35 / 777.98 2 2
Average= 4.21
(KJ/cycle)

Cycle 183 GMT 7/ 8/2022 14:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 29 15.03 0 0 0.00 / 769.38 2 2
2 7 2004.80 46 14.15 2923 1903 1.90 / 771.28 2 2
3 13 1605.20 21 14.23 2471 738 2.64 / 772.02 2 2
4 13 1026.32 21 14.41 1729 523 3.16 / 772.54 2 2
5 13 321.64 21 14.76 787 244 3.41 / 772.79 2 2
6 13 18.20 21 14.95 323 101 3.51 / 772.89 2 2
7 8 0.00 165 14.92 301 741 4.25 / 773.63 2 2
Average= 4.20
(KJ/cycle)

Cycle 182 GMT 28/ 7/2022 14:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 29 15.04 0 0 0.00 / 765.27 2 2
2 7 2002.40 46 14.14 2933 1908 1.91 / 767.18 2 2
3 13 1591.48 21 14.24 2461 736 2.64 / 767.91 2 2
4 13 905.80 21 14.47 1570 477 3.12 / 768.39 2 2
5 13 352.96 21 14.74 828 256 3.38 / 768.64 2 2
6 8 -0.08 165 14.93 298 734 4.11 / 769.38 2 2
Average= 4.20
(KJ/cycle)

Cycle 181 GMT 18/ 7/2022 15:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 27 15.03 0 0 0.00 / 761.12 2 2
2 3 1044.24 1 15.35 0 0 0.00 / 761.12 2 2
3 7 2004.56 46 14.14 2922 1901 1.90 / 763.02 2 2
4 13 1606.00 21 14.24 2461 736 2.64 / 763.76 2 2
5 13 1039.28 21 14.40 1748 529 3.17 / 764.29 2 2
6 13 336.32 21 14.75 810 251 3.42 / 764.54 2 2
7 8 0.24 165 14.93 296 729 4.15 / 765.27 2 2
Average= 4.20
(KJ/cycle)

Cycle 180 GMT 8/ 7/2022 15:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 29 15.02 0 0 0.00 / 756.80 2 2
2 3 961.76 -1 15.35 0 0 0.00 / 756.80 2 2
3 7 2004.48 46 14.15 2946 1918 1.92 / 758.72 2 2
4 13 1729.92 21 14.21 2622 782 2.70 / 759.50 2 2
5 13 1032.40 21 14.42 1734 525 3.23 / 760.02 2 2
6 13 338.68 21 14.75 811 251 3.48 / 760.27 2 2
7 13 49.32 21 14.94 367 115 3.59 / 760.39 2 2
8 8 0.40 165 14.92 298 734 4.33 / 761.12 2 2
Average= 4.21
(KJ/cycle)

Cycle 179 GMT 28/ 6/2022 15:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 29 15.03 0 0 0.00 / 752.61 2 2
2 7 2005.28 46 14.15 2928 1906 1.91 / 754.51 2 2
3 13 1477.16 21 14.27 2304 690 2.60 / 755.20 2 2
4 13 934.12 21 14.45 1610 489 3.08 / 755.69 2 2
5 13 366.00 21 14.73 846 262 3.35 / 755.95 2 2
6 13 47.68 21 14.93 363 114 3.46 / 756.07 2 2
7 8 0.24 165 14.92 297 731 4.19 / 756.80 2 2
Average= 4.20
(KJ/cycle)

Cycle 178 GMT 18/ 6/2022 16:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 29 15.02 0 0 0.00 / 748.42 2 2
2 7 2002.04 46 14.15 2903 1890 1.89 / 750.31 2 2
3 13 1455.56 21 14.28 2290 687 2.58 / 750.99 2 2
4 13 1048.96 21 14.40 1759 532 3.11 / 751.53 2 2
5 13 335.84 21 14.75 809 251 3.36 / 751.78 2 2
6 13 20.64 21 14.95 320 100 3.46 / 751.88 2 2
7 8 -0.04 165 14.93 296 729 4.19 / 752.61 2 2
Average= 4.20
(KJ/cycle)

Cycle 177 GMT 8/ 6/2022 16:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 29 15.03 0 0 0.00 / 744.07 2 2
2 7 2002.80 46 14.15 2931 1908 1.91 / 745.98 2 2
3 13 1735.44 21 14.21 2606 778 2.69 / 746.76 2 2
4 13 1002.40 21 14.44 1706 517 3.20 / 747.27 2 2
5 13 426.76 21 14.70 932 288 3.49 / 747.56 2 2
6 13 59.16 21 14.93 386 121 3.61 / 747.68 2 2
7 8 0.20 165 14.92 299 736 4.35 / 748.42 2 2
Average= 4.20
(KJ/cycle)

Cycle 176 GMT 29/ 5/2022 16:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 29 15.03 0 0 0.00 / 739.75 2 2
2 7 2002.12 46 14.16 2923 1904 1.90 / 741.66 2 2
3 13 1594.24 21 14.25 2447 732 2.64 / 742.39 2 2
4 13 1035.40 21 14.41 1753 530 3.17 / 742.92 2 2
5 13 460.52 21 14.68 984 303 3.47 / 743.22 2 2
6 13 37.96 21 14.94 350 110 3.58 / 743.33 2 2
7 8 -0.32 165 14.92 299 736 4.32 / 744.07 2 2
Average= 4.20
(KJ/cycle)

Cycle 175 GMT 19/ 5/2022 17:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 29 15.03 0 0 0.00 / 735.43 2 2
2 7 2003.44 46 14.15 2948 1919 1.92 / 737.35 2 2
3 13 1596.20 21 14.25 2446 732 2.65 / 738.08 2 2
4 13 1028.80 21 14.42 1737 526 3.18 / 738.61 2 2
5 13 462.00 21 14.68 984 303 3.48 / 738.91 2 2
6 13 39.04 21 14.94 350 110 3.59 / 739.02 2 2
7 8 0.44 165 14.93 297 732 4.32 / 739.75 2 2
Average= 4.20
(KJ/cycle)

Cycle 174 GMT 9/ 5/2022 17:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 29 15.04 0 0 0.00 / 731.10 2 2
2 7 2007.48 46 14.15 2933 1909 1.91 / 733.01 2 2
3 13 1733.60 21 14.20 2646 789 2.70 / 733.80 2 2
4 13 1023.44 21 14.43 1729 524 3.22 / 734.32 2 2
5 13 315.52 21 14.77 780 242 3.46 / 734.57 2 2
6 13 79.84 21 14.92 417 131 3.59 / 734.70 2 2
7 8 -0.12 165 14.93 299 737 4.33 / 735.43 2 2
Average= 4.20
(KJ/cycle)

Cycle 173 GMT 29/ 4/2022 18: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 29 15.04 0 0 0.00 / 726.80 2 2
2 7 2010.44 46 14.15 2943 1916 1.92 / 728.71 2 2
3 13 1597.28 21 14.25 2437 729 2.64 / 729.44 2 2
4 13 1023.76 21 14.43 1727 523 3.17 / 729.97 2 2
5 13 444.84 21 14.69 963 297 3.47 / 730.26 2 2
6 13 16.12 21 14.96 317 100 3.56 / 730.36 2 2
7 8 0.04 165 14.93 300 739 4.30 / 731.10 2 2
Average= 4.20
(KJ/cycle)

Cycle 172 GMT 19/ 4/2022 18:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 29 15.04 0 0 0.00 / 722.43 2 2
2 7 2007.36 47 14.16 2936 1954 1.95 / 724.39 2 2
3 13 1605.92 21 14.25 2465 738 2.69 / 725.13 2 2
4 13 1164.08 21 14.36 1911 576 3.27 / 725.70 2 2
5 13 292.40 21 14.79 746 232 3.50 / 725.93 2 2
6 13 72.24 21 14.93 406 127 3.63 / 726.06 2 2
7 8 0.00 165 14.93 299 737 4.36 / 726.80 2 2
Average= 4.20
(KJ/cycle)

Cycle 171 GMT 9/ 4/2022 19:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 29 15.04 0 0 0.00 / 718.18 2 2
2 7 2009.88 46 14.16 2928 1907 1.91 / 720.08 2 2
3 13 1488.08 21 14.28 2323 697 2.60 / 720.78 2 2
4 13 1069.60 21 14.40 1786 540 3.14 / 721.32 2 2
5 13 352.44 21 14.75 829 257 3.40 / 721.58 2 2
6 13 48.72 21 14.95 370 116 3.52 / 721.69 2 2
7 8 0.20 165 14.93 301 741 4.26 / 722.43 2 2
Average= 4.20
(KJ/cycle)

Cycle 170 GMT 30/ 3/2022 19:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 28 15.04 0 0 0.00 / 713.80 2 2
2 3 1049.60 1 15.36 0 0 0.00 / 713.80 2 2
3 7 2004.44 46 14.16 2929 1908 1.91 / 715.71 2 2
4 13 1600.76 21 14.25 2452 734 2.64 / 716.44 2 2
5 13 1171.00 21 14.37 1913 577 3.22 / 717.02 2 2
6 13 438.48 21 14.70 948 293 3.51 / 717.31 2 2
7 13 63.36 21 14.93 397 124 3.64 / 717.43 2 2
8 8 -0.12 165 14.93 301 741 4.38 / 718.18 2 2
Average= 4.20
(KJ/cycle)

Cycle 169 GMT 20/ 3/2022 19:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 29 15.04 0 0 0.00 / 709.42 2 2
2 3 953.64 -1 15.37 0 0 0.00 / 709.42 2 2
3 7 2004.84 46 14.17 2905 1894 1.89 / 711.31 2 2
4 13 1737.08 21 14.23 2612 781 2.67 / 712.09 2 2
5 13 1158.28 21 14.37 1903 574 3.25 / 712.67 2 2
6 13 420.20 21 14.71 929 287 3.54 / 712.95 2 2
7 13 32.12 21 14.96 343 108 3.64 / 713.06 2 2
8 8 0.00 165 14.94 299 737 4.38 / 713.80 2 2
Average= 4.20
(KJ/cycle)

Cycle 168 GMT 10/ 3/2022 20:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 29 15.05 0 0 0.00 / 705.05 2 2
2 7 2004.68 47 14.16 2905 1933 1.93 / 706.99 2 2
3 13 1736.00 21 14.22 2623 783 2.72 / 707.77 2 2
4 13 993.48 21 14.45 1693 514 3.23 / 708.28 2 2
5 13 440.04 21 14.71 956 295 3.53 / 708.58 2 2
6 13 33.68 21 14.96 343 108 3.63 / 708.69 2 2
7 8 -0.08 165 14.94 297 732 4.37 / 709.42 2 2
Average= 4.20
(KJ/cycle)

Cycle 167 GMT 28/ 2/2022 20:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 29 15.04 0 0 0.00 / 700.67 2 2
2 7 2006.92 46 14.17 2896 1888 1.89 / 702.56 2 2
3 13 1875.00 21 14.19 2784 830 2.72 / 703.39 2 2
4 13 1098.96 21 14.41 1817 550 3.27 / 703.94 2 2
5 13 383.64 21 14.75 881 273 3.54 / 704.21 2 2
6 13 30.28 21 14.97 339 107 3.65 / 704.32 2 2
7 8 0.08 165 14.95 298 735 4.38 / 705.05 2 2
Average= 4.20
(KJ/cycle)

Cycle 166 GMT 18/ 2/2022 21:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 29 15.04 0 0 0.00 / 696.43 2 2
2 7 2004.36 46 14.17 2912 1898 1.90 / 698.32 2 2
3 13 1601.96 21 14.25 2463 737 2.64 / 699.06 2 2
4 13 1027.76 21 14.44 1722 522 3.16 / 699.58 2 2
5 13 322.16 21 14.78 787 244 3.40 / 699.83 2 2
6 13 36.96 21 14.96 351 110 3.51 / 699.94 2 2
7 8 0.28 165 14.94 297 732 4.24 / 700.67 2 2
Average= 4.20
(KJ/cycle)

Cycle 165 GMT 8/ 2/2022 22:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 28 15.05 0 0 0.00 / 692.12 2 2
2 7 2007.88 46 14.15 2941 1914 1.91 / 694.04 2 2
3 13 1594.68 21 14.26 2443 732 2.65 / 694.77 2 2
4 13 1022.68 21 14.44 1713 519 3.17 / 695.29 2 2
5 13 449.76 21 14.70 958 296 3.46 / 695.58 2 2
6 13 33.96 21 14.96 350 110 3.57 / 695.69 2 2
7 8 -0.12 165 14.94 298 735 4.31 / 696.43 2 2
Average= 4.20
(KJ/cycle)

Cycle 164 GMT 29/ 1/2022 22:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 28 15.05 0 0 0.00 / 687.88 2 2
2 7 2006.76 46 14.16 2926 1906 1.91 / 689.78 2 2
3 13 1595.16 21 14.26 2452 734 2.64 / 690.52 2 2
4 13 1036.16 21 14.43 1729 524 3.16 / 691.04 2 2
5 13 319.16 21 14.79 779 242 3.41 / 691.28 2 2
6 13 19.36 21 14.97 324 102 3.51 / 691.39 2 2
7 8 0.00 165 14.95 298 735 4.24 / 692.12 2 2
Average= 4.19
(KJ/cycle)

Cycle 163 GMT 19/ 1/2022 23:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 28 15.05 0 0 0.00 / 683.58 2 2
2 7 2004.60 46 14.16 2927 1907 1.91 / 685.49 2 2
3 13 1599.80 21 14.26 2457 736 2.64 / 686.22 2 2
4 13 1031.92 21 14.43 1734 525 3.17 / 686.75 2 2
5 13 448.64 21 14.71 960 297 3.46 / 687.04 2 2
6 13 17.04 21 14.97 318 100 3.56 / 687.14 2 2
7 8 -0.08 165 14.95 298 735 4.30 / 687.88 2 2
Average= 4.19
(KJ/cycle)

Cycle 162 GMT 9/ 1/2022 23:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 28 15.05 0 0 0.00 / 679.33 2 2
2 7 2008.96 47 14.16 2914 1939 1.94 / 681.27 2 2
3 13 1591.12 21 14.27 2441 731 2.67 / 682.00 2 2
4 13 906.48 21 14.49 1566 477 3.15 / 682.48 2 2
5 13 345.00 21 14.77 817 253 3.40 / 682.73 2 2
6 13 19.84 21 14.97 331 104 3.50 / 682.83 2 2
7 8 -0.28 165 14.94 302 744 4.25 / 683.58 2 2
Average= 4.19
(KJ/cycle)

Cycle 161 GMT 31/12/2021 0:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 28 15.05 0 0 0.00 / 674.95 2 2
2 7 2003.60 46 14.16 2943 1917 1.92 / 676.87 2 2
3 13 1734.04 21 14.22 2630 785 2.70 / 677.65 2 2
4 13 1025.32 21 14.45 1717 521 3.22 / 678.17 2 2
5 13 453.28 21 14.71 971 300 3.52 / 678.47 2 2
6 13 33.36 21 14.97 349 110 3.63 / 678.58 2 2
7 8 -0.16 165 14.95 303 747 4.38 / 679.33 2 2
Average= 4.19
(KJ/cycle)

Cycle 160 GMT 21/12/2021 0:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 28 15.06 0 0 0.00 / 670.69 2 2
2 7 2005.56 46 14.17 2934 1912 1.91 / 672.60 2 2
3 13 1586.96 21 14.27 2445 733 2.65 / 673.33 2 2
4 13 1157.84 21 14.38 1903 575 3.22 / 673.91 2 2
5 13 432.08 21 14.72 940 291 3.51 / 674.20 2 2
6 8 0.08 165 14.96 305 753 4.26 / 674.95 2 2
Average= 4.19
(KJ/cycle)

Cycle 159 GMT 11/12/2021 1:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 28 15.04 0 0 0.00 / 666.57 2 2
2 7 2004.00 46 14.16 2924 1905 1.90 / 668.47 2 2
3 13 1588.80 21 14.26 2438 730 2.63 / 669.20 2 2
4 13 1015.80 21 14.45 1702 516 3.15 / 669.72 2 2
5 13 310.68 21 14.80 761 237 3.39 / 669.96 2 2
6 8 0.08 165 14.96 296 731 4.12 / 670.69 2 2
Average= 4.19
(KJ/cycle)

Cycle 158 GMT 1/12/2021 1:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 28 15.04 0 0 0.00 / 662.28 2 2
2 7 2008.44 47 14.17 2911 1939 1.94 / 664.21 2 2
3 13 1588.64 21 14.26 2447 733 2.67 / 664.95 2 2
4 13 901.88 21 14.50 1555 473 3.14 / 665.42 2 2
5 13 468.20 21 14.70 985 304 3.45 / 665.72 2 2
6 13 17.60 21 14.98 321 101 3.55 / 665.83 2 2
7 8 0.16 165 14.94 301 742 4.29 / 666.57 2 2
Average= 4.19
(KJ/cycle)

Cycle 157 GMT 21/11/2021 2: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 28 15.05 0 0 0.00 / 657.96 2 2
2 7 2005.60 46 14.17 2915 1900 1.90 / 659.86 2 2
3 13 1600.96 21 14.27 2458 737 2.64 / 660.60 2 2
4 13 1023.40 21 14.45 1717 521 3.16 / 661.12 2 2
5 13 442.92 21 14.71 952 294 3.45 / 661.41 2 2
6 13 28.68 21 14.97 345 108 3.56 / 661.52 2 2
7 8 0.00 165 14.94 306 754 4.31 / 662.28 2 2
Average= 4.19
(KJ/cycle)

Cycle 156 GMT 11/11/2021 2:42: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 28 15.05 0 0 0.00 / 653.77 2 2
2 7 2003.64 46 14.16 2924 1905 1.90 / 655.67 2 2
3 13 1598.28 21 14.28 2435 730 2.63 / 656.40 2 2
4 13 1025.16 21 14.44 1728 524 3.16 / 656.92 2 2
5 13 442.96 21 14.71 951 294 3.45 / 657.22 2 2
6 8 0.04 165 14.95 301 742 4.20 / 657.96 2 2
Average= 4.19
(KJ/cycle)

Cycle 155 GMT 1/11/2021 3:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 28 15.05 0 0 0.00 / 649.61 2 2
2 7 2004.76 46 14.17 2915 1900 1.90 / 651.51 2 2
3 13 1601.60 21 14.27 2454 735 2.64 / 652.25 2 2
4 13 1037.60 21 14.44 1734 526 3.16 / 652.77 2 2
5 13 335.24 21 14.78 803 249 3.41 / 653.02 2 2
6 8 -0.24 165 14.96 301 743 4.15 / 653.77 2 2
Average= 4.19
(KJ/cycle)

Cycle 154 GMT 22/10/2021 3:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 28 15.04 0 0 0.00 / 645.51 2 2
2 7 2003.28 46 14.17 2908 1895 1.90 / 647.40 2 2
3 13 1470.72 21 14.31 2284 686 2.58 / 648.09 2 2
4 13 1063.04 21 14.42 1771 536 3.12 / 648.63 2 2
5 13 339.88 21 14.78 804 250 3.37 / 648.87 2 2
6 8 0.04 165 14.95 299 738 4.11 / 649.61 2 2
Average= 4.19
(KJ/cycle)

Cycle 153 GMT 12/10/2021 3:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 28 15.03 0 0 0.00 / 641.34 2 2
2 7 2004.68 46 14.16 2898 1888 1.89 / 643.22 2 2
3 13 1607.28 21 14.26 2446 732 2.62 / 643.96 2 2
4 13 1059.68 21 14.42 1774 537 3.16 / 644.49 2 2
5 13 347.44 21 14.77 820 254 3.41 / 644.75 2 2
6 8 0.12 165 14.95 308 760 4.17 / 645.51 2 2
Average= 4.19
(KJ/cycle)

Cycle 152 GMT 2/10/2021 4:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 28 15.04 0 0 0.00 / 637.19 2 2
2 7 2005.72 46 14.16 2922 1903 1.90 / 639.10 2 2
3 13 1475.44 21 14.29 2303 691 2.59 / 639.79 2 2
4 13 926.80 21 14.48 1593 484 3.08 / 640.27 2 2
5 13 484.80 21 14.68 1007 310 3.39 / 640.58 2 2
6 8 0.28 165 14.94 305 752 4.14 / 641.34 2 2
Average= 4.19
(KJ/cycle)

Cycle 151 GMT 22/ 9/2021 4:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 29 15.04 0 0 0.00 / 633.14 2 2
2 7 1850.56 46 14.22 2733 1788 1.79 / 634.93 2 2
3 13 1580.48 21 14.29 2413 724 2.51 / 635.65 2 2
4 13 1002.92 21 14.46 1695 515 3.03 / 636.16 2 2
5 13 413.32 21 14.73 915 283 3.31 / 636.45 2 2
6 8 0.20 165 14.95 303 747 4.06 / 637.19 2 2
Average= 4.19
(KJ/cycle)

Cycle 150 GMT 12/ 9/2021 3:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 27 15.05 0 0 0.00 / 628.97 2 2
2 3 1052.68 1 15.34 0 0 0.00 / 628.97 2 2
3 7 2003.96 46 14.17 2918 1902 1.90 / 630.87 2 2
4 13 1609.28 21 14.26 2455 735 2.64 / 631.60 2 2
5 13 1043.04 21 14.44 1742 528 3.17 / 632.13 2 2
6 13 346.56 21 14.77 815 253 3.42 / 632.38 2 2
7 8 0.16 165 14.94 306 754 4.17 / 633.14 2 2
Average= 4.19
(KJ/cycle)

Cycle 149 GMT 2/ 9/2021 3:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 27 15.04 0 0 0.00 / 624.79 2 2
2 7 2004.04 47 14.17 2914 1941 1.94 / 626.73 2 2
3 13 1585.04 21 14.27 2440 731 2.67 / 627.46 2 2
4 13 1012.40 21 14.45 1708 518 3.19 / 627.98 2 2
5 13 304.40 21 14.80 757 235 3.43 / 628.22 2 2
6 8 0.20 165 14.94 303 747 4.17 / 628.97 2 2
Average= 4.19
(KJ/cycle)

Cycle 148 GMT 23/ 8/2021 4:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 28 15.03 0 0 0.00 / 620.55 2 2
2 3 963.12 -1 15.35 0 0 0.00 / 620.55 2 2
3 7 2004.68 46 14.16 2938 1914 1.91 / 622.46 2 2
4 13 1729.88 21 14.23 2611 780 2.69 / 623.24 2 2
5 13 1002.12 21 14.46 1688 513 3.21 / 623.75 2 2
6 13 423.72 21 14.72 930 287 3.49 / 624.04 2 2
7 8 0.08 165 14.94 305 752 4.25 / 624.79 2 2
Average= 4.19
(KJ/cycle)

Cycle 147 GMT 13/ 8/2021 4:56: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 26 15.04 0 0 0.00 / 616.21 2 2
2 3 1078.92 2 15.35 0 0 0.00 / 616.21 2 2
3 3 1023.12 1 15.36 0 0 0.00 / 616.21 2 2
4 7 2005.84 46 14.17 2913 1899 1.90 / 618.11 2 2
5 13 1589.56 21 14.28 2434 730 2.63 / 618.84 2 2
6 13 1030.48 21 14.44 1739 527 3.16 / 619.37 2 2
7 13 461.16 21 14.70 983 303 3.46 / 619.67 2 2
8 13 36.24 21 14.95 355 111 3.57 / 619.79 2 2
9 8 0.20 165 14.93 309 761 4.33 / 620.55 2 2
Average= 4.19
(KJ/cycle)

Cycle 146 GMT 3/ 8/2021 5:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 28 15.03 0 0 0.00 / 611.96 2 2
2 3 938.48 -1 15.35 0 0 0.00 / 611.96 2 2
3 3 973.32 -1 15.37 0 0 0.00 / 611.96 2 2
4 7 2005.68 46 14.17 2926 1907 1.91 / 613.86 2 2
5 13 1734.72 21 14.24 2605 779 2.69 / 614.64 2 2
6 13 1016.92 21 14.45 1713 520 3.21 / 615.16 2 2
7 13 443.88 21 14.71 959 296 3.50 / 615.46 2 2
8 8 0.04 165 14.94 307 757 4.26 / 616.21 2 2
Average= 4.19
(KJ/cycle)

Cycle 145 GMT 24/ 7/2021 5:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 27 15.04 0 0 0.00 / 607.85 2 2
2 3 1028.16 1 15.35 0 0 0.00 / 607.85 2 2
3 7 2002.68 46 14.17 2915 1900 1.90 / 609.75 2 2
4 13 1594.60 21 14.28 2433 730 2.63 / 610.48 2 2
5 13 898.40 21 14.51 1553 473 3.10 / 610.95 2 2
6 13 346.24 21 14.77 819 254 3.36 / 611.20 2 2
7 8 -0.08 165 14.95 305 752 4.11 / 611.96 2 2
Average= 4.19
(KJ/cycle)

Cycle 144 GMT 14/ 7/2021 6:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 29 15.03 0 0 0.00 / 603.66 2 2
2 3 962.32 -1 15.35 0 0 0.00 / 603.66 2 2
3 7 2004.56 46 14.18 2904 1894 1.89 / 605.55 2 2
4 13 1580.56 21 14.28 2416 725 2.62 / 606.28 2 2
5 13 1031.72 21 14.45 1732 526 3.14 / 606.80 2 2
6 13 455.40 21 14.70 965 298 3.44 / 607.10 2 2
7 8 -0.04 165 14.94 302 744 4.19 / 607.85 2 2
Average= 4.19
(KJ/cycle)

Cycle 143 GMT 4/ 7/2021 6:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 29 15.04 0 0 0.00 / 599.46 2 2
2 7 2008.24 46 14.18 2919 1904 1.90 / 601.36 2 2
3 13 1596.96 21 14.27 2451 734 2.64 / 602.10 2 2
4 13 1030.96 21 14.45 1736 527 3.17 / 602.62 2 2
5 13 453.56 21 14.70 966 298 3.46 / 602.92 2 2
6 8 0.20 165 14.94 300 740 4.20 / 603.66 2 2
Average= 4.19
(KJ/cycle)

Cycle 142 GMT 24/ 6/2021 7:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 29 15.04 0 0 0.00 / 595.17 2 2
2 7 2004.08 46 14.17 2924 1906 1.91 / 597.07 2 2
3 13 1729.12 21 14.24 2620 783 2.69 / 597.86 2 2
4 13 1127.12 21 14.41 1852 560 3.25 / 598.42 2 2
5 13 413.08 21 14.73 915 283 3.53 / 598.70 2 2
6 8 0.24 165 14.95 307 757 4.29 / 599.46 2 2
Average= 4.19
(KJ/cycle)

Cycle 141 GMT 14/ 6/2021 8: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 29 15.05 0 0 0.00 / 590.93 2 2
2 7 2008.04 46 14.17 2925 1907 1.91 / 592.84 2 2
3 13 1611.36 21 14.27 2448 734 2.64 / 593.57 2 2
4 13 1059.48 21 14.43 1772 537 3.18 / 594.11 2 2
5 13 475.12 21 14.69 1005 310 3.49 / 594.42 2 2
6 8 0.20 165 14.94 304 749 4.24 / 595.17 2 2
Average= 4.19
(KJ/cycle)

Cycle 140 GMT 4/ 6/2021 8:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 29 15.04 0 0 0.00 / 586.67 2 2
2 7 2003.48 47 14.18 2913 1941 1.94 / 588.61 2 2
3 13 1583.96 21 14.28 2442 732 2.67 / 589.35 2 2
4 13 1142.76 21 14.40 1875 567 3.24 / 589.91 2 2
5 13 402.20 21 14.74 895 277 3.52 / 590.19 2 2
6 8 0.16 165 14.95 300 740 4.26 / 590.93 2 2
Average= 4.19
(KJ/cycle)

Cycle 139 GMT 25/ 5/2021 8:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 28 15.05 0 0 0.00 / 582.48 2 2
2 7 2007.96 46 14.18 2919 1904 1.90 / 584.38 2 2
3 13 1594.28 21 14.28 2447 734 2.64 / 585.12 2 2
4 13 1018.32 21 14.45 1705 517 3.16 / 585.63 2 2
5 13 442.64 21 14.72 952 294 3.45 / 585.93 2 2
6 8 0.24 165 14.95 302 745 4.19 / 586.67 2 2
Average= 4.19
(KJ/cycle)

Cycle 138 GMT 15/ 5/2021 9:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 29 15.05 0 0 0.00 / 578.31 2 2
2 7 2005.72 46 14.17 2934 1912 1.91 / 580.23 2 2
3 13 1600.72 21 14.28 2462 738 2.65 / 580.96 2 2
4 13 1030.56 21 14.45 1733 526 3.18 / 581.49 2 2
5 13 327.92 21 14.78 792 246 3.42 / 581.74 2 2
6 8 0.00 165 14.95 301 742 4.16 / 582.48 2 2
Average= 4.19
(KJ/cycle)

Cycle 137 GMT 5/ 5/2021 9:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 28 15.04 0 0 0.00 / 574.16 2 2
2 3 1040.92 1 15.35 0 0 0.00 / 574.16 2 2
3 7 2002.24 46 14.18 2920 1905 1.90 / 576.07 2 2
4 13 1592.48 21 14.28 2451 735 2.64 / 576.80 2 2
5 13 1026.28 21 14.45 1724 523 3.16 / 577.33 2 2
6 13 318.08 21 14.80 781 243 3.41 / 577.57 2 2
7 8 0.04 165 14.95 301 742 4.15 / 578.31 2 2
Average= 4.19
(KJ/cycle)

Cycle 136 GMT 25/ 4/2021 10: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 29 15.04 0 0 0.00 / 569.83 2 2
2 3 968.48 -1 15.36 0 0 0.00 / 569.83 2 2
3 7 2004.60 46 14.17 2931 1910 1.91 / 571.74 2 2
4 13 1598.40 21 14.28 2467 740 2.65 / 572.48 2 2
5 13 1028.04 21 14.45 1729 525 3.17 / 573.01 2 2
6 13 447.28 21 14.71 959 296 3.47 / 573.31 2 2
7 13 34.52 21 14.96 351 110 3.58 / 573.42 2 2
8 8 0.00 165 14.94 304 749 4.33 / 574.16 2 2
Average= 4.19
(KJ/cycle)

Cycle 135 GMT 15/ 4/2021 10:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 28 15.05 0 0 0.00 / 565.62 2 2
2 3 1037.32 1 15.36 0 0 0.00 / 565.62 2 2
3 7 2003.20 47 14.17 2936 1955 1.96 / 567.57 2 2
4 13 1459.96 21 14.33 2272 684 2.64 / 568.26 2 2
5 13 1040.24 21 14.45 1742 529 3.17 / 568.79 2 2
6 13 453.60 21 14.71 971 300 3.47 / 569.09 2 2
7 8 0.12 165 14.95 303 747 4.22 / 569.83 2 2
Average= 4.19
(KJ/cycle)

Cycle 134 GMT 5/ 4/2021 11:10: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 29 15.04 0 0 0.00 / 561.38 2 2
2 3 950.68 -1 15.36 0 0 0.00 / 561.38 2 2
3 7 2004.28 46 14.19 2903 1895 1.89 / 563.28 2 2
4 13 1591.88 21 14.29 2458 738 2.63 / 564.02 2 2
5 13 1007.20 21 14.47 1700 517 3.15 / 564.53 2 2
6 13 301.40 21 14.81 752 234 3.38 / 564.77 2 2
7 13 37.84 21 14.97 354 111 3.49 / 564.88 2 2
8 8 -0.12 165 14.95 300 740 4.23 / 565.62 2 2
Average= 4.19
(KJ/cycle)

Cycle 133 GMT 26/ 3/2021 11:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.52 29 15.04 0 0 0.00 / 557.08 2 2
2 7 2005.60 46 14.17 2927 1908 1.91 / 558.99 2 2
3 13 1728.84 21 14.26 2602 779 2.69 / 559.77 2 2
4 13 1018.60 21 14.46 1713 520 3.21 / 560.29 2 2
5 13 316.00 21 14.80 777 241 3.45 / 560.53 2 2
6 13 36.76 21 14.97 351 110 3.56 / 560.64 2 2
7 8 0.20 165 14.95 302 745 4.30 / 561.38 2 2
Average= 4.19
(KJ/cycle)

Cycle 132 GMT 16/ 3/2021 12: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 29 15.05 0 0 0.00 / 552.80 2 2
2 7 2008.56 46 14.18 2928 1910 1.91 / 554.71 2 2
3 13 1480.72 21 14.32 2315 696 2.61 / 555.41 2 2
4 13 1071.40 21 14.43 1785 541 3.15 / 555.95 2 2
5 13 356.76 21 14.77 846 262 3.41 / 556.21 2 2
6 13 44.20 21 14.96 371 117 3.53 / 556.33 2 2
7 8 0.16 165 14.94 305 752 4.28 / 557.08 2 2
Average= 4.19
(KJ/cycle)

Cycle 131 GMT 6/ 3/2021 12:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 29 15.05 0 0 0.00 / 548.47 2 2
2 7 2003.56 47 14.18 2935 1956 1.96 / 550.43 2 2
3 13 1591.24 21 14.29 2461 739 2.69 / 551.17 2 2
4 13 1022.00 21 14.46 1715 521 3.22 / 551.69 2 2
5 13 319.40 21 14.80 781 243 3.46 / 551.93 2 2
6 13 36.00 21 14.97 360 113 3.57 / 552.04 2 2
7 8 0.36 165 14.95 308 760 4.33 / 552.80 2 2
Average= 4.19
(KJ/cycle)

Cycle 130 GMT 24/ 2/2021 13: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 28 15.05 0 0 0.00 / 544.16 2 2
2 7 2005.08 46 14.18 2921 1905 1.91 / 546.06 2 2
3 13 1602.04 21 14.29 2454 736 2.64 / 546.80 2 2
4 13 1032.20 21 14.46 1734 527 3.17 / 547.33 2 2
5 13 443.40 21 14.72 950 294 3.46 / 547.62 2 2
6 13 32.80 21 14.97 345 108 3.57 / 547.73 2 2
7 8 -0.16 165 14.95 301 742 4.31 / 548.47 2 2
Average= 4.19
(KJ/cycle)

Cycle 129 GMT 14/ 2/2021 13:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 28 15.06 0 0 0.00 / 539.81 2 2
2 7 2004.00 47 14.18 2926 1950 1.95 / 541.76 2 2
3 13 1604.92 21 14.29 2459 738 2.69 / 542.50 2 2
4 13 1164.40 21 14.40 1908 577 3.26 / 543.08 2 2
5 13 305.00 21 14.81 759 236 3.50 / 543.31 2 2
6 13 34.12 21 14.97 346 109 3.61 / 543.42 2 2
7 8 0.16 165 14.95 299 738 4.35 / 544.16 2 2
Average= 4.19
(KJ/cycle)

Cycle 128 GMT 4/ 2/2021 14: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 28 15.06 0 0 0.00 / 535.59 2 2
2 7 2009.20 46 14.19 2903 1895 1.89 / 537.48 2 2
3 13 1594.68 21 14.29 2449 735 2.63 / 538.22 2 2
4 13 1034.52 21 14.46 1726 524 3.15 / 538.74 2 2
5 13 313.24 21 14.81 758 236 3.39 / 538.98 2 2
6 13 19.36 21 14.99 317 100 3.49 / 539.08 2 2
7 8 -0.12 165 14.95 298 735 4.22 / 539.81 2 2
Average= 4.18
(KJ/cycle)

Cycle 127 GMT 25/ 1/2021 14:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 28 15.05 0 0 0.00 / 531.38 2 2
2 7 2006.92 46 14.19 2897 1891 1.89 / 533.27 2 2
3 13 1592.00 21 14.30 2435 731 2.62 / 534.00 2 2
4 13 1022.88 21 14.47 1720 523 3.14 / 534.52 2 2
5 13 311.68 21 14.81 762 237 3.38 / 534.76 2 2
6 13 16.88 21 14.99 318 100 3.48 / 534.86 2 2
7 8 -0.08 165 14.96 295 728 4.21 / 535.59 2 2
Average= 4.18
(KJ/cycle)

Cycle 126 GMT 15/ 1/2021 14:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 28 15.05 0 0 0.00 / 527.12 2 2
2 7 2005.64 46 14.18 2936 1915 1.92 / 529.04 2 2
3 13 1592.32 21 14.29 2442 733 2.65 / 529.77 2 2
4 13 1023.68 21 14.47 1712 520 3.17 / 530.29 2 2
5 13 312.68 21 14.81 768 239 3.41 / 530.53 2 2
6 13 18.24 21 14.98 325 102 3.51 / 530.63 2 2
7 8 0.16 165 14.95 303 747 4.26 / 531.38 2 2
Average= 4.18
(KJ/cycle)

Cycle 125 GMT 5/ 1/2021 15:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 28 15.06 0 0 0.00 / 522.75 2 2
2 7 2006.72 46 14.19 2902 1894 1.89 / 524.65 2 2
3 13 1596.44 21 14.30 2434 731 2.63 / 525.38 2 2
4 13 1154.48 21 14.41 1895 573 3.20 / 525.95 2 2
5 13 542.32 21 14.68 1076 332 3.53 / 526.28 2 2
6 13 24.12 21 14.98 330 104 3.63 / 526.39 2 2
7 8 -0.16 165 14.96 297 733 4.37 / 527.12 2 2
Average= 4.18
(KJ/cycle)

Cycle 124 GMT 26/12/2020 16:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 28 15.06 0 0 0.00 / 518.54 2 2
2 7 2005.64 46 14.19 2923 1908 1.91 / 520.45 2 2
3 13 1600.20 21 14.29 2451 736 2.64 / 521.18 2 2
4 13 908.96 21 14.52 1565 477 3.12 / 521.66 2 2
5 13 351.68 21 14.79 824 256 3.38 / 521.92 2 2
6 13 19.80 21 14.99 325 102 3.48 / 522.02 2 2
7 8 0.04 165 14.96 298 736 4.21 / 522.75 2 2
Average= 4.18
(KJ/cycle)

Cycle 123 GMT 16/12/2020 16:30:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 28 15.06 0 0 0.00 / 514.35 2 2
2 7 2006.24 46 14.20 2911 1901 1.90 / 516.25 2 2
3 13 1596.24 21 14.30 2444 734 2.64 / 516.99 2 2
4 13 1020.48 21 14.47 1714 521 3.16 / 517.51 2 2
5 13 447.28 21 14.73 954 295 3.45 / 517.80 2 2
6 8 -0.12 165 14.97 298 736 4.19 / 518.54 2 2
Average= 4.18
(KJ/cycle)

Cycle 122 GMT 6/12/2020 17: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 28 15.06 0 0 0.00 / 510.19 2 2
2 7 2002.84 46 14.19 2922 1907 1.91 / 512.10 2 2
3 13 1596.12 21 14.30 2446 735 2.64 / 512.83 2 2
4 13 1039.12 21 14.47 1733 527 3.17 / 513.36 2 2
5 13 327.68 21 14.81 791 246 3.41 / 513.60 2 2
6 8 -0.08 165 14.96 303 748 4.16 / 514.35 2 2
Average= 4.18
(KJ/cycle)

Cycle 121 GMT 26/11/2020 17:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 28 15.06 0 0 0.00 / 506.00 2 2
2 7 2005.28 46 14.19 2917 1904 1.90 / 507.91 2 2
3 13 1731.48 21 14.27 2603 780 2.68 / 508.69 2 2
4 13 1003.76 21 14.49 1688 514 3.20 / 509.20 2 2
5 13 305.92 21 14.82 759 236 3.43 / 509.44 2 2
6 8 0.16 165 14.96 304 750 4.18 / 510.19 2 2
Average= 4.18
(KJ/cycle)

Cycle 120 GMT 16/11/2020 18: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 28 15.06 0 0 0.00 / 501.78 2 2
2 7 2004.04 46 14.19 2920 1906 1.91 / 503.68 2 2
3 13 1600.68 21 14.30 2463 740 2.65 / 504.42 2 2
4 13 1034.48 21 14.47 1731 526 3.17 / 504.95 2 2
5 13 453.76 21 14.73 968 299 3.47 / 505.25 2 2
6 8 0.36 165 14.96 306 755 4.23 / 506.00 2 2
Average= 4.18
(KJ/cycle)

Cycle 119 GMT 6/11/2020 18:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 28 15.06 0 0 0.00 / 497.52 2 2
2 7 2009.56 46 14.19 2938 1918 1.92 / 499.44 2 2
3 13 1607.12 21 14.31 2436 732 2.65 / 500.17 2 2
4 13 1150.00 21 14.42 1886 571 3.22 / 500.74 2 2
5 13 414.08 21 14.75 918 284 3.51 / 501.02 2 2
6 8 -0.08 165 14.96 306 755 4.26 / 501.78 2 2
Average= 4.18
(KJ/cycle)

Cycle 118 GMT 27/10/2020 19: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 27 15.06 0 0 0.00 / 493.31 2 2
2 7 2002.80 46 14.20 2910 1901 1.90 / 495.21 2 2
3 13 1594.40 21 14.30 2460 739 2.64 / 495.95 2 2
4 13 1017.64 21 14.48 1718 522 3.16 / 496.47 2 2
5 13 427.72 21 14.74 936 290 3.45 / 496.76 2 2
6 8 0.12 165 14.96 307 758 4.21 / 497.52 2 2
Average= 4.18
(KJ/cycle)

Cycle 117 GMT 17/10/2020 19:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 28 15.06 0 0 0.00 / 489.11 2 2
2 7 2005.76 46 14.19 2937 1917 1.92 / 491.03 2 2
3 13 1475.92 21 14.34 2302 693 2.61 / 491.72 2 2
4 13 1050.32 21 14.46 1750 531 3.14 / 492.25 2 2
5 13 466.76 21 14.72 983 304 3.45 / 492.56 2 2
6 8 0.20 165 14.96 305 753 4.20 / 493.31 2 2
Average= 4.18
(KJ/cycle)

Cycle 116 GMT 7/10/2020 19:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 28 15.06 0 0 0.00 / 484.94 2 2
2 7 2002.52 46 14.20 2917 1905 1.91 / 486.85 2 2
3 13 1597.24 21 14.31 2441 734 2.64 / 487.58 2 2
4 13 1032.36 21 14.47 1731 526 3.16 / 488.11 2 2
5 13 328.48 21 14.81 797 248 3.41 / 488.35 2 2
6 8 0.32 165 14.97 306 756 4.17 / 489.11 2 2
Average= 4.18
(KJ/cycle)

Cycle 115 GMT 27/ 9/2020 20:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 28 15.06 0 0 0.00 / 480.76 2 2
2 7 2003.68 46 14.19 2925 1909 1.91 / 482.67 2 2
3 13 1599.08 21 14.31 2456 738 2.65 / 483.40 2 2
4 13 1032.20 21 14.47 1738 528 3.18 / 483.93 2 2
5 13 323.00 21 14.81 792 246 3.42 / 484.18 2 2
6 8 0.12 165 14.96 309 763 4.18 / 484.94 2 2
Average= 4.18
(KJ/cycle)

Cycle 114 GMT 17/ 9/2020 20:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 27 15.06 0 0 0.00 / 476.69 2 2
2 7 1915.28 44 14.25 2800 1756 1.76 / 478.44 2 2
3 13 1645.84 21 14.31 2526 759 2.51 / 479.20 2 2
4 13 967.68 21 14.52 1646 502 3.02 / 479.71 2 2
5 13 402.52 21 14.77 902 280 3.30 / 479.99 2 2
6 8 -0.08 165 14.97 312 771 4.07 / 480.76 2 2
Average= 4.18
(KJ/cycle)

Cycle 113 GMT 7/ 9/2020 19:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 28 15.06 0 0 0.00 / 472.40 2 2
2 7 2001.96 44 14.20 2926 1828 1.83 / 474.23 2 2
3 13 1732.60 21 14.28 2636 790 2.62 / 475.02 2 2
4 13 1144.04 21 14.44 1885 572 3.19 / 475.59 2 2
5 13 558.60 21 14.68 1111 342 3.53 / 475.93 2 2
6 8 0.00 165 14.97 306 756 4.29 / 476.69 2 2
Average= 4.18
(KJ/cycle)

Cycle 112 GMT 28/ 8/2020 19:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 28 15.06 0 0 0.00 / 468.22 2 2
2 7 2003.12 44 14.20 2944 1839 1.84 / 470.05 2 2
3 13 1599.20 21 14.32 2463 741 2.58 / 470.80 2 2
4 13 1044.92 21 14.47 1758 534 3.11 / 471.33 2 2
5 13 466.84 21 14.73 995 308 3.42 / 471.64 2 2
6 8 -0.04 165 14.97 309 763 4.19 / 472.40 2 2
Average= 4.18
(KJ/cycle)

Cycle 111 GMT 18/ 8/2020 20:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 28 15.06 0 0 0.00 / 464.09 2 2
2 7 2003.56 44 14.20 2948 1842 1.84 / 465.93 2 2
3 13 1596.20 21 14.31 2460 739 2.58 / 466.67 2 2
4 13 1039.36 21 14.48 1744 530 3.11 / 467.20 2 2
5 13 331.16 21 14.81 809 252 3.36 / 467.45 2 2
6 8 0.04 165 14.97 308 761 4.12 / 468.22 2 2
Average= 4.18
(KJ/cycle)

Cycle 110 GMT 8/ 8/2020 20:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 28 15.06 0 0 0.00 / 459.87 2 2
2 7 2001.88 44 14.20 2932 1832 1.83 / 461.70 2 2
3 13 1737.00 21 14.28 2640 792 2.62 / 462.49 2 2
4 13 1032.76 21 14.48 1743 530 3.15 / 463.02 2 2
5 13 464.64 21 14.73 990 306 3.46 / 463.33 2 2
6 8 0.16 165 14.97 309 763 4.22 / 464.09 2 2
Average= 4.18
(KJ/cycle)

Cycle 109 GMT 29/ 7/2020 21: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 28 15.07 0 0 0.00 / 455.60 2 2
2 7 2003.20 44 14.20 2932 1832 1.83 / 457.43 2 2
3 13 1598.48 21 14.32 2461 740 2.57 / 458.17 2 2
4 13 1176.92 21 14.42 1929 584 3.16 / 458.75 2 2
5 13 581.44 21 14.67 1145 353 3.51 / 459.11 2 2
6 8 0.32 165 14.97 309 763 4.27 / 459.87 2 2
Average= 4.18
(KJ/cycle)

Cycle 108 GMT 19/ 7/2020 21:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 28 15.07 0 0 0.00 / 451.41 2 2
2 7 2006.48 44 14.21 2939 1838 1.84 / 453.25 2 2
3 13 1597.08 21 14.32 2464 741 2.58 / 453.99 2 2
4 13 1033.68 21 14.48 1748 532 3.11 / 454.52 2 2
5 13 455.88 21 14.74 979 303 3.41 / 454.83 2 2
6 8 0.20 165 14.97 312 771 4.18 / 455.60 2 2
Average= 4.18
(KJ/cycle)

Cycle 107 GMT 9/ 7/2020 22: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 28 15.07 0 0 0.00 / 447.22 2 2
2 7 2003.88 44 14.21 2931 1833 1.83 / 449.06 2 2
3 13 1602.96 21 14.32 2462 740 2.57 / 449.80 2 2
4 13 1051.68 21 14.48 1766 537 3.11 / 450.33 2 2
5 13 473.12 21 14.73 1004 311 3.42 / 450.64 2 2
6 8 0.32 165 14.98 311 769 4.19 / 451.41 2 2
Average= 4.18
(KJ/cycle)

Cycle 106 GMT 29/ 6/2020 22:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 28 15.07 0 0 0.00 / 443.09 2 2
2 7 2008.24 44 14.21 2935 1835 1.84 / 444.93 2 2
3 13 1610.36 21 14.31 2491 749 2.58 / 445.68 2 2
4 13 1045.20 21 14.48 1758 535 3.12 / 446.21 2 2
5 13 345.48 21 14.81 827 257 3.38 / 446.47 2 2
6 8 0.28 165 14.98 305 754 4.13 / 447.22 2 2
Average= 4.18
(KJ/cycle)

Cycle 105 GMT 19/ 6/2020 22:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 28 15.07 0 0 0.00 / 438.94 2 2
2 7 2004.96 44 14.21 2935 1835 1.84 / 440.78 2 2
3 13 1494.52 21 14.35 2330 702 2.54 / 441.48 2 2
4 13 1077.28 21 14.47 1802 548 3.08 / 442.03 2 2
5 13 492.52 21 14.72 1018 315 3.40 / 442.34 2 2
6 8 -0.08 165 14.98 305 754 4.15 / 443.09 2 2
Average= 4.18
(KJ/cycle)

Cycle 104 GMT 9/ 6/2020 22:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 28 15.08 0 0 0.00 / 434.71 2 2
2 7 2003.68 44 14.22 2915 1824 1.82 / 436.53 2 2
3 13 1736.48 21 14.28 2630 789 2.61 / 437.32 2 2
4 13 1152.12 21 14.45 1889 573 3.19 / 437.89 2 2
5 13 432.04 21 14.76 947 294 3.48 / 438.18 2 2
6 8 0.00 165 14.98 306 756 4.24 / 438.94 2 2
Average= 4.18
(KJ/cycle)

Cycle 103 GMT 30/ 5/2020 23:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 28 15.08 0 0 0.00 / 430.56 2 2
2 7 2008.76 44 14.21 2942 1839 1.84 / 432.40 2 2
3 13 1744.36 21 14.28 2624 787 2.63 / 433.18 2 2
4 13 1015.28 21 14.50 1711 521 3.15 / 433.70 2 2
5 13 337.16 21 14.81 811 252 3.40 / 433.96 2 2
6 8 0.04 165 14.98 303 749 4.15 / 434.71 2 2
Average= 4.18
(KJ/cycle)

Cycle 102 GMT 20/ 5/2020 23:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 28 15.07 0 0 0.00 / 426.41 2 2
2 7 2002.68 44 14.22 2930 1833 1.83 / 428.25 2 2
3 13 1587.76 21 14.32 2437 733 2.57 / 428.98 2 2
4 13 1030.04 21 14.49 1729 526 3.09 / 429.50 2 2
5 13 460.20 21 14.74 978 303 3.39 / 429.81 2 2
6 8 0.16 165 14.98 303 749 4.14 / 430.56 2 2
Average= 4.18
(KJ/cycle)

Cycle 101 GMT 11/ 5/2020 0: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 28 15.08 0 0 0.00 / 422.26 2 2
2 7 2005.40 44 14.21 2934 1834 1.83 / 424.10 2 2
3 13 1592.88 21 14.33 2426 730 2.56 / 424.83 2 2
4 13 1028.88 21 14.49 1734 528 3.09 / 425.36 2 2
5 13 447.80 21 14.75 961 298 3.39 / 425.65 2 2
6 8 0.36 165 14.98 307 759 4.15 / 426.41 2 2
Average= 4.18
(KJ/cycle)

Cycle 100 GMT 1/ 5/2020 0:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 27 15.08 0 0 0.00 / 418.05 2 2
2 3 1038.68 1 15.38 0 0 0.00 / 418.05 2 2
3 3 1021.44 1 15.40 0 0 0.00 / 418.05 2 2
4 7 2006.16 44 14.22 2925 1830 1.83 / 419.88 2 2
5 13 1731.68 21 14.30 2583 776 2.61 / 420.65 2 2
6 13 1136.84 21 14.45 1869 567 3.17 / 421.22 2 2
7 13 399.64 21 14.78 901 280 3.45 / 421.50 2 2
8 8 0.20 165 14.98 309 764 4.22 / 422.26 2 2
Average= 4.18
(KJ/cycle)

Cycle 99 GMT 21/ 4/2020 1:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 28 15.07 0 0 0.00 / 413.95 2 2
2 3 968.72 -1 15.39 0 0 0.00 / 413.95 2 2
3 7 2003.72 44 14.22 2903 1816 1.82 / 415.77 2 2
4 13 1610.96 21 14.32 2465 741 2.56 / 416.51 2 2
5 13 1054.16 21 14.48 1750 532 3.09 / 417.04 2 2
6 13 347.56 21 14.81 827 257 3.35 / 417.30 2 2
7 8 0.04 165 14.99 302 747 4.09 / 418.05 2 2
Average= 4.18
(KJ/cycle)

Cycle 98 GMT 11/ 4/2020 1:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 28 15.07 0 0 0.00 / 409.67 2 2
2 7 2003.88 44 14.23 2923 1830 1.83 / 411.50 2 2
3 13 1585.32 21 14.34 2441 735 2.57 / 412.24 2 2
4 13 1151.32 21 14.45 1876 569 3.13 / 412.81 2 2
5 13 414.12 21 14.78 913 283 3.42 / 413.09 2 2
6 13 30.32 21 15.00 349 110 3.53 / 413.20 2 2
7 8 -0.08 165 14.98 304 751 4.28 / 413.95 2 2
Average= 4.18
(KJ/cycle)

Cycle 97 GMT 1/ 4/2020 2:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 28 15.08 0 0 0.00 / 405.46 2 2
2 7 2004.44 44 14.22 2898 1813 1.81 / 407.28 2 2
3 13 1602.00 21 14.33 2461 741 2.55 / 408.02 2 2
4 13 1049.44 21 14.49 1753 533 3.09 / 408.55 2 2
5 13 346.80 21 14.81 824 256 3.34 / 408.81 2 2
6 13 40.72 21 15.00 361 114 3.46 / 408.92 2 2
7 8 0.36 165 14.98 305 754 4.21 / 409.67 2 2
Average= 4.18
(KJ/cycle)

Cycle 96 GMT 22/ 3/2020 2:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 28 15.08 0 0 0.00 / 401.14 2 2
2 7 2003.12 44 14.23 2911 1823 1.82 / 402.96 2 2
3 13 1728.08 21 14.30 2604 782 2.60 / 403.74 2 2
4 13 1146.40 21 14.46 1877 570 3.17 / 404.31 2 2
5 13 413.72 21 14.78 909 282 3.46 / 404.59 2 2
6 13 28.20 21 15.01 346 109 3.57 / 404.70 2 2
7 8 0.00 165 14.98 308 761 4.33 / 405.46 2 2
Average= 4.18
(KJ/cycle)

Cycle 95 GMT 12/ 3/2020 3:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 28 15.08 0 0 0.00 / 396.77 2 2
2 7 2003.92 45 14.22 2908 1861 1.86 / 398.63 2 2
3 13 1732.80 21 14.29 2621 787 2.65 / 399.41 2 2
4 13 1148.56 21 14.45 1884 572 3.22 / 399.99 2 2
5 13 421.48 21 14.78 922 286 3.51 / 400.27 2 2
6 13 32.72 21 15.01 349 110 3.62 / 400.38 2 2
7 8 -0.12 165 14.98 305 754 4.37 / 401.14 2 2
Average= 4.18
(KJ/cycle)

Cycle 94 GMT 2/ 3/2020 3:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 28 15.06 0 0 0.00 / 392.49 2 2
2 7 2006.88 44 14.21 2931 1833 1.83 / 394.32 2 2
3 13 1612.00 21 14.32 2471 743 2.58 / 395.06 2 2
4 13 1050.28 21 14.49 1763 536 3.11 / 395.60 2 2
5 13 469.52 21 14.75 988 306 3.42 / 395.90 2 2
6 13 18.92 21 15.01 334 105 3.52 / 396.01 2 2
7 8 -0.16 165 14.98 307 759 4.28 / 396.77 2 2
Average= 4.18
(KJ/cycle)

Cycle 93 GMT 21/ 2/2020 4: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 28 15.08 0 0 0.00 / 387.93 2 2
2 3 1019.20 1 15.39 0 0 0.00 / 387.93 2 2
3 7 2002.84 44 14.22 2919 1826 1.83 / 389.76 2 2
4 13 1602.40 21 14.33 2458 740 2.57 / 390.50 2 2
5 13 1038.80 21 14.50 1742 530 3.10 / 391.03 2 2
6 13 336.72 21 14.83 807 251 3.35 / 391.28 2 2
7 13 21.04 21 15.02 339 107 3.45 / 391.39 2 2
8 8 -0.08 165 14.98 306 756 4.21 / 392.14 2 2
9 14 -0.08 75 14.95 305 342 4.55 / 392.49 2 35
Average= 4.18
(KJ/cycle)

Cycle 92 GMT 11/ 2/2020 4:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 28 15.08 0 0 0.00 / 383.76 2 2
2 7 2003.12 44 14.23 2895 1813 1.81 / 385.57 2 2
3 13 1474.88 21 14.37 2306 696 2.51 / 386.26 2 2
4 13 1057.68 21 14.49 1763 536 3.04 / 386.80 2 2
5 13 350.60 21 14.82 835 260 3.30 / 387.06 2 2
6 13 23.84 21 15.01 343 108 3.41 / 387.17 2 2
7 8 -0.08 165 14.98 309 764 4.18 / 387.93 2 2
Average= 4.17
(KJ/cycle)

Cycle 91 GMT 1/ 2/2020 4:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 28 15.07 0 0 0.00 / 379.45 2 2
2 7 2005.24 44 14.23 2909 1821 1.82 / 381.27 2 2
3 13 1733.40 21 14.30 2603 782 2.60 / 382.05 2 2
4 13 1016.68 21 14.51 1713 522 3.13 / 382.58 2 2
5 13 441.88 21 14.77 947 294 3.42 / 382.87 2 2
6 13 21.80 21 15.01 348 110 3.53 / 382.98 2 2
7 8 0.20 165 14.98 314 776 4.30 / 383.76 2 2
Average= 4.17
(KJ/cycle)

Cycle 90 GMT 22/ 1/2020 5:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 28 15.08 0 0 0.00 / 375.21 2 2
2 7 2004.52 44 14.22 2922 1828 1.83 / 377.04 2 2
3 13 1608.52 21 14.33 2472 744 2.57 / 377.78 2 2
4 13 1033.68 21 14.51 1730 527 3.10 / 378.31 2 2
5 13 341.16 21 14.82 823 256 3.36 / 378.56 2 2
6 13 23.20 21 15.00 350 110 3.47 / 378.67 2 2
7 8 0.20 165 14.98 314 776 4.24 / 379.45 2 2
Average= 4.17
(KJ/cycle)

Cycle 89 GMT 12/ 1/2020 5:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 28 15.07 0 0 0.00 / 370.99 2 2
2 7 2003.56 44 14.23 2903 1818 1.82 / 372.80 2 2
3 13 1601.48 21 14.34 2449 737 2.56 / 373.54 2 2
4 13 1046.76 21 14.50 1747 532 3.09 / 374.07 2 2
5 13 347.84 21 14.82 830 258 3.35 / 374.33 2 2
6 13 23.40 21 15.01 345 109 3.45 / 374.44 2 2
7 8 0.12 165 14.98 311 769 4.22 / 375.21 2 2
Average= 4.17
(KJ/cycle)

Cycle 88 GMT 2/ 1/2020 6: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 28 15.08 0 0 0.00 / 366.65 2 2
2 7 2008.96 44 14.22 2937 1838 1.84 / 368.49 2 2
3 13 1601.32 21 14.34 2451 738 2.58 / 369.22 2 2
4 13 1174.92 21 14.45 1911 580 3.16 / 369.80 2 2
5 13 439.96 21 14.77 945 293 3.45 / 370.10 2 2
6 13 30.52 21 15.00 360 113 3.56 / 370.21 2 2
7 8 0.04 165 14.98 314 776 4.34 / 370.99 2 2
Average= 4.17
(KJ/cycle)

Cycle 87 GMT 23/12/2019 6:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 28 15.09 0 0 0.00 / 362.43 2 2
2 7 2007.24 44 14.23 2924 1831 1.83 / 364.26 2 2
3 13 1606.04 21 14.34 2474 745 2.58 / 365.01 2 2
4 13 1041.44 21 14.51 1737 529 3.11 / 365.54 2 2
5 13 322.44 21 14.84 787 245 3.35 / 365.78 2 2
6 13 17.64 21 15.02 335 106 3.46 / 365.89 2 2
7 8 -0.28 165 14.98 307 759 4.21 / 366.65 2 2
Average= 4.17
(KJ/cycle)

Cycle 86 GMT 13/12/2019 7: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 28 15.08 0 0 0.00 / 358.28 2 2
2 7 2003.20 44 14.23 2916 1826 1.83 / 360.11 2 2
3 13 1722.00 21 14.31 2614 786 2.61 / 360.90 2 2
4 13 1010.92 21 14.52 1699 518 3.13 / 361.41 2 2
5 13 320.20 21 14.84 785 245 3.37 / 361.66 2 2
6 8 0.24 165 15.00 313 775 4.15 / 362.43 2 2
Average= 4.17
(KJ/cycle)

Cycle 85 GMT 3/12/2019 7:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 28 15.09 0 0 0.00 / 354.05 2 2
2 7 2007.60 44 14.22 2936 1837 1.84 / 355.88 2 2
3 13 1604.76 21 14.34 2468 743 2.58 / 356.63 2 2
4 13 1039.04 21 14.51 1741 531 3.11 / 357.16 2 2
5 13 347.08 21 14.83 817 254 3.37 / 357.41 2 2
6 13 23.04 21 15.02 341 108 3.47 / 357.52 2 2
7 8 0.08 165 14.99 309 764 4.24 / 358.28 2 2
Average= 4.17
(KJ/cycle)

Cycle 84 GMT 23/11/2019 7:51:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 27 15.09 0 0 0.00 / 349.94 2 2
2 7 2007.88 44 14.23 2910 1822 1.82 / 351.76 2 2
3 13 1607.68 21 14.34 2471 744 2.57 / 352.51 2 2
4 13 1034.80 21 14.51 1732 528 3.09 / 353.03 2 2
5 13 327.40 21 14.84 800 249 3.34 / 353.28 2 2
6 8 0.16 165 15.00 309 765 4.11 / 354.05 2 2
Average= 4.17
(KJ/cycle)

Cycle 83 GMT 13/11/2019 8:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 27 15.09 0 0 0.00 / 345.82 2 2
2 7 2006.92 44 14.23 2921 1829 1.83 / 347.65 2 2
3 13 1599.44 21 14.35 2459 741 2.57 / 348.39 2 2
4 13 1036.84 21 14.52 1734 529 3.10 / 348.92 2 2
5 13 326.72 21 14.84 795 248 3.35 / 349.17 2 2
6 8 0.08 165 14.99 312 772 4.12 / 349.94 2 2
Average= 4.17
(KJ/cycle)

Cycle 82 GMT 3/11/2019 8:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 27 15.09 0 0 0.00 / 341.64 2 2
2 7 2006.80 44 14.24 2904 1820 1.82 / 343.45 2 2
3 13 1733.04 21 14.32 2593 780 2.60 / 344.23 2 2
4 13 1024.20 21 14.52 1717 524 3.12 / 344.76 2 2
5 13 461.64 21 14.77 970 301 3.42 / 345.06 2 2
6 8 0.00 165 15.00 308 762 4.19 / 345.82 2 2
Average= 4.17
(KJ/cycle)

Cycle 81 GMT 24/10/2019 9:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 27 15.09 0 0 0.00 / 337.37 2 2
2 7 2008.56 45 14.25 2891 1854 1.85 / 339.22 2 2
3 13 1740.56 21 14.32 2614 786 2.64 / 340.01 2 2
4 13 1153.40 21 14.47 1884 572 3.21 / 340.58 2 2
5 13 428.72 21 14.79 933 290 3.50 / 340.87 2 2
6 8 -0.12 165 15.00 310 767 4.27 / 341.64 2 2
Average= 4.17
(KJ/cycle)

Cycle 80 GMT 14/10/2019 9:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 28 15.09 0 0 0.00 / 333.24 2 2
2 7 2005.76 44 14.23 2917 1826 1.83 / 335.07 2 2
3 13 1602.04 21 14.35 2458 741 2.57 / 335.81 2 2
4 13 1028.56 21 14.52 1727 527 3.09 / 336.34 2 2
5 13 332.84 21 14.84 802 250 3.34 / 336.59 2 2
6 8 -0.08 165 14.99 315 779 4.12 / 337.37 2 2
Average= 4.17
(KJ/cycle)

Cycle 79 GMT 4/10/2019 10:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 28 15.09 0 0 0.00 / 329.07 2 2
2 7 2007.32 44 14.23 2917 1826 1.83 / 330.89 2 2
3 13 1600.96 21 14.36 2463 743 2.57 / 331.63 2 2
4 13 1034.60 21 14.52 1739 530 3.10 / 332.16 2 2
5 13 457.64 21 14.77 972 301 3.40 / 332.47 2 2
6 8 0.28 165 15.00 314 777 4.18 / 333.24 2 2
Average= 4.17
(KJ/cycle)

Cycle 78 GMT 24/ 9/2019 10:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 27 15.09 0 0 0.00 / 324.87 2 2
2 3 1030.84 1 15.40 0 0 0.00 / 324.87 2 2
3 7 2002.52 44 14.24 2913 1825 1.83 / 326.70 2 2
4 13 1604.20 21 14.35 2478 747 2.57 / 327.44 2 2
5 13 1036.72 21 14.52 1738 530 3.10 / 327.97 2 2
6 13 468.72 21 14.77 991 307 3.41 / 328.28 2 2
7 8 -0.04 165 15.00 317 785 4.19 / 329.07 2 2
Average= 4.17
(KJ/cycle)

Cycle 77 GMT 14/ 9/2019 11: 5: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 27 15.09 0 0 0.00 / 320.61 2 2
2 7 2005.36 44 14.24 2916 1827 1.83 / 322.44 2 2
3 13 1596.28 21 14.36 2448 738 2.57 / 323.18 2 2
4 13 1039.80 21 14.52 1738 530 3.10 / 323.71 2 2
5 13 339.56 21 14.85 805 251 3.35 / 323.96 2 2
6 13 110.08 21 14.98 467 147 3.49 / 324.11 2 2
7 8 -0.04 165 15.00 309 765 4.26 / 324.87 2 2
Average= 4.17
(KJ/cycle)

Cycle 76 GMT 4/ 9/2019 11:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 28 15.09 0 0 0.00 / 316.43 2 2
2 3 962.60 -1 15.40 0 0 0.00 / 316.43 2 2
3 7 2005.56 44 14.24 2906 1821 1.82 / 318.25 2 2
4 13 1735.28 21 14.32 2621 788 2.61 / 319.03 2 2
5 13 1142.88 21 14.49 1872 570 3.18 / 319.60 2 2
6 13 296.00 21 14.87 751 235 3.41 / 319.84 2 2
7 8 0.04 165 15.00 313 775 4.19 / 320.61 2 2
Average= 4.16
(KJ/cycle)

Cycle 75 GMT 25/ 8/2019 11:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 28 15.09 0 0 0.00 / 312.24 2 2
2 7 2003.60 44 14.25 2896 1816 1.82 / 314.06 2 2
3 13 1727.28 21 14.33 2599 782 2.60 / 314.84 2 2
4 13 1011.84 21 14.54 1705 521 3.12 / 315.36 2 2
5 13 432.84 21 14.80 935 291 3.41 / 315.65 2 2
6 8 -0.20 165 15.00 314 777 4.19 / 316.43 2 2
Average= 4.16
(KJ/cycle)

Cycle 74 GMT 15/ 8/2019 12:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 27 15.09 0 0 0.00 / 308.00 2 2
2 3 1023.68 1 15.40 0 0 0.00 / 308.00 2 2
3 7 2003.76 44 14.25 2909 1824 1.82 / 309.82 2 2
4 13 1733.84 21 14.32 2610 785 2.61 / 310.61 2 2
5 13 1142.64 21 14.49 1870 569 3.18 / 311.18 2 2
6 13 433.00 21 14.80 938 292 3.47 / 311.47 2 2
7 8 -0.04 165 15.00 312 772 4.24 / 312.24 2 2
Average= 4.16
(KJ/cycle)

Cycle 73 GMT 5/ 8/2019 13:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 29 15.10 0 0 0.00 / 303.66 2 2
2 3 968.64 -1 15.40 0 0 0.00 / 303.66 2 2
3 7 2007.72 44 14.25 2907 1823 1.82 / 305.49 2 2
4 13 1594.88 21 14.36 2461 742 2.56 / 306.23 2 2
5 13 1160.52 21 14.48 1897 577 3.14 / 306.81 2 2
6 13 421.96 21 14.80 927 288 3.43 / 307.09 2 2
7 13 57.60 21 15.01 396 125 3.55 / 307.22 2 2
8 8 0.16 165 15.00 315 780 4.33 / 308.00 2 2
Average= 4.16
(KJ/cycle)

Cycle 72 GMT 26/ 7/2019 13:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 28 15.10 0 0 0.00 / 299.49 2 2
2 3 1040.44 1 15.41 0 0 0.00 / 299.49 2 2
3 7 2007.00 44 14.24 2931 1836 1.84 / 301.32 2 2
4 13 1734.00 21 14.33 2604 784 2.62 / 302.11 2 2
5 13 1029.84 21 14.53 1734 529 3.15 / 302.64 2 2
6 13 335.52 21 14.85 805 251 3.40 / 302.89 2 2
7 8 -0.12 165 15.00 314 777 4.18 / 303.66 2 2
Average= 4.16
(KJ/cycle)

Cycle 71 GMT 16/ 7/2019 14:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 28 15.09 0 0 0.00 / 295.32 2 2
2 7 2003.00 44 14.25 2886 1810 1.81 / 297.13 2 2
3 13 1614.56 21 14.36 2470 745 2.55 / 297.87 2 2
4 13 1054.60 21 14.52 1765 538 3.09 / 298.41 2 2
5 13 473.28 21 14.77 994 308 3.40 / 298.72 2 2
6 8 0.24 165 15.01 309 765 4.17 / 299.49 2 2
Average= 4.16
(KJ/cycle)

Cycle 70 GMT 6/ 7/2019 14:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 28 15.10 0 0 0.00 / 291.10 2 2
2 7 2007.08 44 14.26 2919 1831 1.83 / 292.93 2 2
3 13 1597.12 21 14.37 2462 743 2.57 / 293.68 2 2
4 13 1028.04 21 14.54 1714 523 3.10 / 294.20 2 2
5 13 329.88 21 14.86 791 247 3.34 / 294.45 2 2
6 13 38.44 21 15.03 363 115 3.46 / 294.56 2 2
7 8 -0.04 165 15.00 307 760 4.22 / 295.32 2 2
Average= 4.16
(KJ/cycle)

Cycle 69 GMT 26/ 6/2019 15:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 29 15.10 0 0 0.00 / 286.90 2 2
2 3 960.44 -1 15.41 0 0 0.00 / 286.90 2 2
3 7 2003.84 44 14.26 2905 1823 1.82 / 288.72 2 2
4 13 1618.32 21 14.37 2444 738 2.56 / 289.46 2 2
5 13 1181.04 21 14.48 1916 583 3.14 / 290.04 2 2
6 13 440.76 21 14.80 951 296 3.44 / 290.34 2 2
7 8 0.04 165 15.01 309 765 4.20 / 291.10 2 2
Average= 4.16
(KJ/cycle)

Cycle 68 GMT 16/ 6/2019 16: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 27 15.11 0 0 0.00 / 282.73 2 2
2 3 1053.24 1 15.41 0 0 0.00 / 282.73 2 2
3 3 1019.44 1 15.43 0 0 0.00 / 282.73 2 2
4 7 2007.92 44 14.25 2946 1847 1.85 / 284.58 2 2
5 13 1601.64 21 14.37 2458 742 2.59 / 285.32 2 2
6 13 1042.92 21 14.54 1755 536 3.12 / 285.85 2 2
7 13 352.56 21 14.85 830 259 3.38 / 286.11 2 2
8 8 0.00 165 15.01 317 785 4.17 / 286.90 2 2
Average= 4.16
(KJ/cycle)

Cycle 67 GMT 6/ 6/2019 16:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 29 15.09 0 0 0.00 / 278.50 2 2
2 3 964.32 -1 15.41 0 0 0.00 / 278.50 2 2
3 7 2004.44 44 14.26 2918 1831 1.83 / 280.33 2 2
4 13 1738.36 21 14.34 2623 790 2.62 / 281.12 2 2
5 13 1138.00 21 14.50 1862 567 3.19 / 281.69 2 2
6 13 409.92 21 14.82 902 281 3.47 / 281.97 2 2
7 8 0.48 165 15.01 308 763 4.23 / 282.73 2 2
Average= 4.16
(KJ/cycle)

Cycle 66 GMT 27/ 5/2019 17:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 29 15.11 0 0 0.00 / 274.20 2 2
2 7 2003.56 44 14.25 2923 1833 1.83 / 276.03 2 2
3 13 1724.24 21 14.35 2607 786 2.62 / 276.82 2 2
4 13 1012.28 21 14.55 1704 521 3.14 / 277.34 2 2
5 13 420.08 21 14.81 921 286 3.43 / 277.63 2 2
6 13 29.24 21 15.03 345 109 3.53 / 277.73 2 2
7 8 0.24 165 15.00 308 762 4.30 / 278.50 2 2
Average= 4.16
(KJ/cycle)

Cycle 65 GMT 17/ 5/2019 17:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 29 15.11 0 0 0.00 / 270.04 2 2
2 7 2006.68 44 14.25 2926 1835 1.83 / 271.88 2 2
3 13 1605.40 21 14.38 2463 744 2.58 / 272.62 2 2
4 13 1171.92 21 14.49 1906 580 3.16 / 273.20 2 2
5 13 312.20 21 14.87 772 241 3.40 / 273.44 2 2
6 8 -0.08 165 15.02 307 761 4.16 / 274.20 2 2
Average= 4.15
(KJ/cycle)

Cycle 64 GMT 7/ 5/2019 18:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 29 15.09 0 0 0.00 / 265.90 2 2
2 7 2007.40 44 14.26 2914 1828 1.83 / 267.73 2 2
3 13 1612.76 21 14.36 2473 746 2.57 / 268.47 2 2
4 13 1064.64 21 14.53 1773 541 3.12 / 269.02 2 2
5 13 350.68 21 14.85 823 257 3.37 / 269.27 2 2
6 8 0.04 165 15.02 310 768 4.14 / 270.04 2 2
Average= 4.15
(KJ/cycle)

Cycle 63 GMT 27/ 4/2019 18:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 29 15.10 0 0 0.00 / 261.61 2 2
2 7 2004.64 44 14.26 2931 1839 1.84 / 263.45 2 2
3 13 1600.96 21 14.38 2451 740 2.58 / 264.19 2 2
4 13 1033.80 21 14.55 1729 528 3.11 / 264.72 2 2
5 13 458.84 21 14.79 984 306 3.41 / 265.02 2 2
6 13 36.44 21 15.03 363 115 3.53 / 265.14 2 2
7 8 0.08 165 15.00 309 765 4.29 / 265.90 2 2
Average= 4.15
(KJ/cycle)

Cycle 62 GMT 17/ 4/2019 19:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 29 15.10 0 0 0.00 / 257.34 2 2
2 7 2003.00 44 14.26 2909 1825 1.83 / 259.16 2 2
3 13 1728.72 21 14.35 2602 784 2.61 / 259.95 2 2
4 13 1016.16 21 14.56 1716 525 3.13 / 260.47 2 2
5 13 326.56 21 14.87 796 249 3.38 / 260.72 2 2
6 13 40.96 21 15.03 373 118 3.50 / 260.84 2 2
7 8 -0.16 165 15.01 311 770 4.27 / 261.61 2 2
Average= 4.15
(KJ/cycle)

Cycle 61 GMT 7/ 4/2019 19:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 27 15.10 0 0 0.00 / 253.04 2 2
2 3 1045.60 1 15.41 0 0 0.00 / 253.04 2 2
3 7 2002.88 45 14.26 2929 1880 1.88 / 254.92 2 2
4 13 1602.32 21 14.38 2457 742 2.62 / 255.66 2 2
5 13 1043.48 21 14.55 1746 533 3.15 / 256.19 2 2
6 13 332.12 21 14.86 807 252 3.41 / 256.44 2 2
7 13 43.92 21 15.03 379 120 3.53 / 256.56 2 2
8 8 -0.04 165 15.01 313 775 4.30 / 257.34 2 2
Average= 4.15
(KJ/cycle)

Cycle 60 GMT 28/ 3/2019 20:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 29 15.10 0 0 0.00 / 248.76 2 2
2 3 946.76 -1 15.41 0 0 0.00 / 248.76 2 2
3 7 2003.40 44 14.27 2909 1827 1.83 / 250.58 2 2
4 13 1595.92 21 14.39 2449 740 2.57 / 251.32 2 2
5 13 1024.88 21 14.56 1723 527 3.09 / 251.85 2 2
6 13 438.88 21 14.81 946 294 3.39 / 252.14 2 2
7 13 59.64 21 15.01 401 126 3.51 / 252.27 2 2
8 8 -0.08 165 15.01 309 765 4.28 / 253.04 2 2
Average= 4.15
(KJ/cycle)

Cycle 59 GMT 18/ 3/2019 20:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 29 15.11 0 0 0.00 / 244.49 2 2
2 7 2006.72 44 14.28 2903 1824 1.82 / 246.31 2 2
3 13 1613.16 21 14.38 2477 748 2.57 / 247.06 2 2
4 13 1166.88 21 14.50 1901 579 3.15 / 247.64 2 2
5 13 304.04 21 14.89 763 239 3.39 / 247.88 2 2
6 13 37.48 21 15.04 364 115 3.50 / 247.99 2 2
7 8 0.16 165 15.01 308 763 4.27 / 248.76 2 2
Average= 4.15
(KJ/cycle)

Cycle 58 GMT 8/ 3/2019 21:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 29 15.11 0 0 0.00 / 240.27 2 2
2 7 2006.24 44 14.27 2921 1834 1.83 / 242.10 2 2
3 13 1601.36 21 14.39 2425 733 2.57 / 242.84 2 2
4 13 1038.60 21 14.56 1737 531 3.10 / 243.37 2 2
5 13 328.68 21 14.87 798 249 3.35 / 243.62 2 2
6 13 21.08 21 15.05 342 108 3.46 / 243.73 2 2
7 8 0.04 165 15.02 308 763 4.22 / 244.49 2 2
Average= 4.14
(KJ/cycle)

Cycle 57 GMT 26/ 2/2019 21:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 29 15.11 0 0 0.00 / 235.97 2 2
2 7 2002.32 44 14.28 2897 1820 1.82 / 237.79 2 2
3 13 1725.76 21 14.36 2602 785 2.60 / 238.58 2 2
4 13 1002.44 21 14.57 1704 521 3.13 / 239.10 2 2
5 13 414.32 21 14.83 916 285 3.41 / 239.39 2 2
6 13 34.12 21 15.04 361 114 3.53 / 239.50 2 2
7 8 0.00 165 15.02 311 771 4.30 / 240.27 2 2
Average= 4.14
(KJ/cycle)

Cycle 56 GMT 16/ 2/2019 22:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 28 15.11 0 0 0.00 / 231.76 2 2
2 7 2004.04 44 14.28 2922 1836 1.84 / 233.59 2 2
3 13 1599.64 21 14.41 2433 736 2.57 / 234.33 2 2
4 13 1031.84 21 14.57 1728 529 3.10 / 234.86 2 2
5 13 326.40 21 14.88 790 247 3.35 / 235.10 2 2
6 13 22.08 21 15.05 342 108 3.46 / 235.21 2 2
7 8 -0.44 165 15.02 308 763 4.22 / 235.97 2 2
Average= 4.14
(KJ/cycle)

Cycle 55 GMT 6/ 2/2019 22:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 28 15.12 0 0 0.00 / 227.41 2 2
2 7 2005.00 44 14.27 2918 1832 1.83 / 229.24 2 2
3 13 1738.80 21 14.36 2607 786 2.62 / 230.03 2 2
4 13 1148.32 21 14.52 1866 569 3.19 / 230.59 2 2
5 13 419.88 21 14.84 916 285 3.47 / 230.88 2 2
6 13 30.36 21 15.05 353 112 3.58 / 230.99 2 2
7 8 -0.12 165 15.02 308 763 4.35 / 231.76 2 2
Average= 4.14
(KJ/cycle)

Cycle 54 GMT 27/ 1/2019 23:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 28 15.12 0 0 0.00 / 223.20 2 2
2 7 2001.96 44 14.28 2916 1832 1.83 / 225.03 2 2
3 13 1599.52 21 14.40 2458 743 2.58 / 225.78 2 2
4 13 1029.08 21 14.57 1724 527 3.10 / 226.30 2 2
5 13 319.60 21 14.89 780 244 3.35 / 226.55 2 2
6 13 18.96 21 15.06 329 104 3.45 / 226.65 2 2
7 8 -0.12 165 15.03 305 756 4.21 / 227.41 2 2
Average= 4.13
(KJ/cycle)

Cycle 53 GMT 17/ 1/2019 23:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 28 15.12 0 0 0.00 / 218.98 2 2
2 7 2007.00 44 14.28 2933 1843 1.84 / 220.82 2 2
3 13 1598.48 21 14.40 2456 743 2.59 / 221.57 2 2
4 13 1025.16 21 14.58 1718 526 3.11 / 222.09 2 2
5 13 321.32 21 14.90 783 245 3.36 / 222.34 2 2
6 13 20.68 21 15.06 333 105 3.46 / 222.44 2 2
7 8 0.04 165 15.03 305 756 4.22 / 223.20 2 2
Average= 4.13
(KJ/cycle)

Cycle 52 GMT 8/ 1/2019 0:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 28 15.13 0 0 0.00 / 214.75 2 2
2 7 2009.16 44 14.29 2907 1828 1.83 / 216.58 2 2
3 13 1619.64 21 14.39 2479 749 2.58 / 217.33 2 2
4 13 1056.48 21 14.57 1758 538 3.11 / 217.86 2 2
5 13 340.80 21 14.89 811 254 3.37 / 218.12 2 2
6 13 19.56 21 15.06 335 106 3.47 / 218.22 2 2
7 8 0.20 165 15.04 306 759 4.23 / 218.98 2 2
Average= 4.13
(KJ/cycle)

Cycle 51 GMT 29/12/2018 0:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 28 15.12 0 0 0.00 / 210.66 2 2
2 7 2009.80 44 14.30 2893 1820 1.82 / 212.48 2 2
3 13 1601.72 21 14.41 2446 740 2.56 / 213.22 2 2
4 13 1035.60 21 14.59 1726 529 3.09 / 213.75 2 2
5 13 327.40 21 14.90 789 247 3.34 / 214.00 2 2
6 8 0.16 165 15.05 302 750 4.09 / 214.75 2 2
Average= 4.13
(KJ/cycle)

Cycle 50 GMT 19/12/2018 1: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 28 15.13 0 0 0.00 / 206.21 2 2
2 7 2007.16 44 14.29 2918 1835 1.83 / 208.04 2 2
3 13 1730.36 21 14.38 2617 790 2.63 / 208.84 2 2
4 13 1282.64 21 14.49 2036 620 3.24 / 209.45 2 2
5 13 516.08 21 14.81 1038 323 3.57 / 209.78 2 2
6 13 45.84 21 15.05 374 118 3.69 / 209.90 2 2
7 8 0.48 165 15.03 309 766 4.45 / 210.66 2 2
Average= 4.13
(KJ/cycle)

Cycle 49 GMT 9/12/2018 1:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 28 15.13 0 0 0.00 / 201.98 2 2
2 7 2004.80 44 14.29 2933 1844 1.84 / 203.83 2 2
3 13 1603.24 21 14.41 2463 745 2.59 / 204.57 2 2
4 13 1028.52 21 14.59 1727 529 3.12 / 205.10 2 2
5 13 320.20 21 14.91 777 243 3.36 / 205.35 2 2
6 13 18.12 21 15.07 332 105 3.47 / 205.45 2 2
7 8 0.16 165 15.04 306 759 4.23 / 206.21 2 2
Average= 4.12
(KJ/cycle)

Cycle 48 GMT 29/11/2018 2:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 28 15.13 0 0 0.00 / 197.86 2 2
2 7 2005.12 44 14.31 2909 1832 1.83 / 199.69 2 2
3 13 1600.24 21 14.42 2449 742 2.57 / 200.44 2 2
4 13 1034.68 21 14.59 1731 530 3.10 / 200.97 2 2
5 13 321.48 21 14.91 782 245 3.35 / 201.21 2 2
6 8 0.12 165 15.05 311 772 4.12 / 201.98 2 2
Average= 4.12
(KJ/cycle)

Cycle 47 GMT 19/11/2018 2:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 28 15.14 0 0 0.00 / 193.69 2 2
2 7 2004.08 44 14.30 2911 1832 1.83 / 195.53 2 2
3 13 1591.76 21 14.43 2441 740 2.57 / 196.27 2 2
4 13 1021.44 21 14.60 1710 524 3.10 / 196.79 2 2
5 13 434.00 21 14.85 942 294 3.39 / 197.08 2 2
6 8 -0.20 165 15.05 314 780 4.17 / 197.86 2 2
Average= 4.12
(KJ/cycle)

Cycle 46 GMT 9/11/2018 3:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 27 15.14 0 0 0.00 / 189.56 2 2
2 7 2006.80 44 14.32 2886 1818 1.82 / 191.38 2 2
3 13 1609.28 21 14.42 2479 751 2.57 / 192.13 2 2
4 13 1047.36 21 14.59 1757 538 3.11 / 192.67 2 2
5 13 325.40 21 14.91 796 249 3.36 / 192.91 2 2
6 8 0.40 165 15.05 314 780 4.14 / 193.69 2 2
Average= 4.12
(KJ/cycle)

Cycle 45 GMT 30/10/2018 4: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 27 15.15 0 0 0.00 / 185.44 2 2
2 7 2001.72 44 14.31 2917 1837 1.84 / 187.28 2 2
3 13 1586.92 21 14.44 2436 739 2.58 / 188.02 2 2
4 13 1022.92 21 14.60 1718 527 3.10 / 188.55 2 2
5 13 313.64 21 14.92 772 242 3.34 / 188.79 2 2
6 8 0.44 165 15.05 310 770 4.11 / 189.56 2 2
Average= 4.12
(KJ/cycle)

Cycle 44 GMT 20/10/2018 4:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 28 15.14 0 0 0.00 / 181.29 2 2
2 7 2001.48 44 14.32 2903 1829 1.83 / 183.12 2 2
3 13 1729.12 21 14.39 2626 794 2.62 / 183.91 2 2
4 13 1015.64 21 14.62 1696 521 3.14 / 184.43 2 2
5 13 319.56 21 14.92 776 243 3.39 / 184.67 2 2
6 8 -0.20 165 15.06 310 770 4.16 / 185.44 2 2
Average= 4.12
(KJ/cycle)

Cycle 43 GMT 10/10/2018 5:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 28 15.15 0 0 0.00 / 177.13 2 2
2 7 2003.12 44 14.32 2909 1833 1.83 / 178.96 2 2
3 13 1599.92 21 14.44 2468 748 2.58 / 179.71 2 2
4 13 1031.16 21 14.61 1721 528 3.11 / 180.24 2 2
5 13 316.24 21 14.93 792 248 3.36 / 180.49 2 2
6 8 -0.04 165 15.05 322 800 4.16 / 181.29 2 2
Average= 4.12
(KJ/cycle)

Cycle 42 GMT 30/ 9/2018 6: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 27 15.16 0 0 0.00 / 173.02 2 2
2 3 1021.76 1 15.43 0 0 0.00 / 173.02 2 2
3 7 2003.76 44 14.33 2892 1823 1.82 / 174.85 2 2
4 13 1602.92 21 14.44 2455 744 2.57 / 175.59 2 2
5 13 920.16 21 14.67 1580 487 3.05 / 176.08 2 2
6 13 360.76 21 14.91 839 263 3.32 / 176.34 2 2
7 8 0.36 165 15.06 317 788 4.11 / 177.13 2 2
Average= 4.12
(KJ/cycle)

Cycle 41 GMT 20/ 9/2018 6:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 27 15.15 0 0 0.00 / 168.89 2 2
2 7 2002.92 44 14.33 2905 1832 1.83 / 170.73 2 2
3 13 1597.96 21 14.45 2429 737 2.57 / 171.46 2 2
4 13 1030.72 21 14.62 1730 531 3.10 / 171.99 2 2
5 13 327.64 21 14.93 791 248 3.35 / 172.24 2 2
6 8 -0.16 165 15.07 315 783 4.13 / 173.02 2 2
Average= 4.12
(KJ/cycle)

Cycle 40 GMT 10/ 9/2018 7: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 27 15.17 0 0 0.00 / 164.65 2 2
2 7 2005.00 44 14.32 2916 1837 1.84 / 166.48 2 2
3 13 1611.08 21 14.45 2454 745 2.58 / 167.23 2 2
4 13 1042.12 21 14.62 1739 534 3.12 / 167.76 2 2
5 13 324.92 21 14.93 788 247 3.36 / 168.01 2 2
6 13 36.64 21 15.09 361 114 3.48 / 168.12 2 2
7 8 0.00 165 15.06 310 770 4.25 / 168.89 2 2
Average= 4.12
(KJ/cycle)

Cycle 39 GMT 31/ 8/2018 7:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 28 15.17 0 0 0.00 / 160.52 2 2
2 7 2002.00 44 14.33 2892 1823 1.82 / 162.35 2 2
3 13 1606.88 21 14.45 2453 744 2.57 / 163.09 2 2
4 13 1039.64 21 14.62 1731 531 3.10 / 163.62 2 2
5 13 331.44 21 14.94 800 251 3.35 / 163.87 2 2
6 8 0.32 165 15.08 310 771 4.12 / 164.65 2 2
Average= 4.12
(KJ/cycle)

Cycle 38 GMT 21/ 8/2018 8: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 27 15.17 0 0 0.00 / 156.42 2 2
2 3 1040.84 1 15.44 0 0 0.00 / 156.42 2 2
3 7 2004.20 44 14.33 2908 1834 1.83 / 158.25 2 2
4 13 1588.92 21 14.46 2438 740 2.57 / 158.99 2 2
5 13 1017.56 21 14.64 1697 522 3.10 / 159.51 2 2
6 13 317.24 21 14.95 774 243 3.34 / 159.76 2 2
7 8 0.28 165 15.08 309 769 4.11 / 160.52 2 2
Average= 4.12
(KJ/cycle)

Cycle 37 GMT 11/ 8/2018 8:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 28 15.16 0 0 0.00 / 152.26 2 2
2 3 963.80 -1 15.45 0 0 0.00 / 152.26 2 2
3 7 2006.64 44 14.34 2909 1835 1.84 / 154.10 2 2
4 13 1734.80 21 14.41 2619 793 2.63 / 154.89 2 2
5 13 1015.04 21 14.64 1703 524 3.15 / 155.41 2 2
6 13 313.28 21 14.96 768 241 3.39 / 155.65 2 2
7 8 0.12 165 15.09 307 764 4.16 / 156.42 2 2
Average= 4.12
(KJ/cycle)

Cycle 36 GMT 1/ 8/2018 9: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 28 15.17 0 0 0.00 / 147.79 2 2
2 7 2002.76 44 14.35 2888 1823 1.82 / 149.62 2 2
3 13 1592.88 21 14.48 2417 735 2.56 / 150.35 2 2
4 13 1023.44 21 14.64 1725 530 3.09 / 150.88 2 2
5 13 332.48 21 14.95 805 253 3.34 / 151.14 2 2
6 8 0.00 165 15.09 311 774 4.12 / 151.91 2 2
7 14 0.00 75 15.06 309 349 4.46 / 152.26 2 2
Average= 4.12
(KJ/cycle)

Cycle 35 GMT 22/ 7/2018 9:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 28 15.19 0 0 0.00 / 143.49 2 2
2 7 2003.20 44 14.36 2918 1844 1.84 / 145.33 2 2
3 13 1721.44 21 14.44 2597 788 2.63 / 146.12 2 2
4 13 988.72 21 14.66 1668 514 3.14 / 146.63 2 2
5 13 407.64 21 14.91 900 282 3.43 / 146.92 2 2
6 13 26.80 21 15.12 346 110 3.54 / 147.03 2 2
7 8 0.00 165 15.09 309 769 4.31 / 147.79 2 2
Average= 4.11
(KJ/cycle)

Cycle 34 GMT 12/ 7/2018 10:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 27 15.18 0 0 0.00 / 139.37 2 2
2 3 1021.32 1 15.45 0 0 0.00 / 139.37 2 2
3 7 2011.60 44 14.35 2921 1844 1.84 / 141.21 2 2
4 13 1600.72 21 14.48 2444 743 2.59 / 141.95 2 2
5 13 1025.36 21 14.65 1715 528 3.12 / 142.48 2 2
6 13 319.76 21 14.96 783 246 3.36 / 142.73 2 2
7 8 0.24 165 15.10 306 762 4.12 / 143.49 2 2
Average= 4.10
(KJ/cycle)

Cycle 33 GMT 2/ 7/2018 10:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 28 15.18 0 0 0.00 / 135.25 2 2
2 3 960.80 -1 15.45 0 0 0.00 / 135.25 2 2
3 7 2005.44 44 14.35 2908 1836 1.84 / 137.08 2 2
4 13 1598.96 21 14.49 2442 743 2.58 / 137.83 2 2
5 13 1022.96 21 14.65 1712 527 3.11 / 138.35 2 2
6 13 314.24 21 14.97 774 243 3.35 / 138.60 2 2
7 8 0.00 165 15.10 308 767 4.12 / 139.37 2 2
Average= 4.10
(KJ/cycle)

Cycle 32 GMT 22/ 6/2018 11:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 28 15.19 0 0 0.00 / 131.01 2 2
2 7 2003.68 44 14.36 2920 1845 1.84 / 132.86 2 2
3 13 1591.68 21 14.48 2436 741 2.59 / 133.60 2 2
4 13 1025.56 21 14.65 1720 529 3.11 / 134.13 2 2
5 13 316.36 21 14.97 775 244 3.36 / 134.37 2 2
6 13 39.68 21 15.12 361 115 3.47 / 134.49 2 2
7 8 0.28 165 15.10 306 762 4.24 / 135.25 2 2
Average= 4.10
(KJ/cycle)

Cycle 31 GMT 12/ 6/2018 11:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 28 15.19 0 0 0.00 / 126.94 2 2
2 7 2006.16 44 14.36 2928 1850 1.85 / 128.79 2 2
3 13 1479.92 21 14.52 2301 702 2.55 / 129.50 2 2
4 13 915.56 21 14.70 1583 489 3.04 / 129.98 2 2
5 13 345.68 21 14.95 825 259 3.30 / 130.24 2 2
6 8 0.32 165 15.11 309 770 4.07 / 131.01 2 2
Average= 4.09
(KJ/cycle)

Cycle 30 GMT 2/ 6/2018 12:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 28 15.19 0 0 0.00 / 122.67 2 2
2 7 2005.84 45 14.36 2932 1895 1.89 / 124.56 2 2
3 13 1593.88 21 14.49 2441 743 2.64 / 125.31 2 2
4 13 1021.40 21 14.67 1707 526 3.16 / 125.83 2 2
5 13 302.20 21 14.98 755 238 3.40 / 126.07 2 2
6 13 34.80 21 15.13 355 113 3.51 / 126.18 2 2
7 8 0.08 165 15.10 305 760 4.27 / 126.94 2 2
Average= 4.09
(KJ/cycle)

Cycle 29 GMT 23/ 5/2018 13: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 28 15.20 0 0 0.00 / 118.28 2 2
2 7 2006.36 44 14.37 2927 1851 1.85 / 120.13 2 2
3 13 1731.48 21 14.46 2605 791 2.64 / 120.92 2 2
4 13 1145.64 21 14.62 1876 576 3.22 / 121.50 2 2
5 13 417.16 21 14.92 924 290 3.51 / 121.79 2 2
6 13 56.48 21 15.12 391 124 3.63 / 121.91 2 2
7 8 -0.24 165 15.11 305 760 4.39 / 122.67 2 2
Average= 4.09
(KJ/cycle)

Cycle 28 GMT 13/ 5/2018 13:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 28 15.20 0 0 0.00 / 114.15 2 2
2 7 2004.36 44 14.37 2929 1852 1.85 / 116.01 2 2
3 13 1595.40 21 14.50 2431 740 2.59 / 116.75 2 2
4 13 1021.16 21 14.67 1709 526 3.12 / 117.27 2 2
5 13 307.76 21 14.99 764 240 3.36 / 117.51 2 2
6 8 -0.08 165 15.12 307 766 4.13 / 118.28 2 2
Average= 4.08
(KJ/cycle)

Cycle 27 GMT 3/ 5/2018 14:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 27 15.20 0 0 0.00 / 109.98 2 2
2 3 1045.56 1 15.47 0 0 0.00 / 109.98 2 2
3 7 2002.84 44 14.38 2910 1841 1.84 / 111.83 2 2
4 13 1580.68 21 14.50 2437 742 2.58 / 112.57 2 2
5 13 1013.80 21 14.67 1711 527 3.11 / 113.09 2 2
6 13 423.24 21 14.93 925 290 3.40 / 113.38 2 2
7 8 0.16 165 15.12 308 768 4.17 / 114.15 2 2
Average= 4.08
(KJ/cycle)

Cycle 26 GMT 23/ 4/2018 15: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 28 15.20 0 0 0.00 / 105.76 2 2
2 3 968.76 -1 15.47 0 0 0.00 / 105.76 2 2
3 7 2002.04 44 14.38 2906 1839 1.84 / 107.60 2 2
4 13 1581.92 21 14.50 2447 745 2.58 / 108.35 2 2
5 13 1011.88 21 14.69 1704 526 3.11 / 108.87 2 2
6 13 298.52 21 15.00 758 239 3.35 / 109.11 2 2
7 13 37.12 21 15.15 357 114 3.46 / 109.22 2 2
8 8 0.12 165 15.12 305 761 4.22 / 109.98 2 2
Average= 4.07
(KJ/cycle)

Cycle 25 GMT 13/ 4/2018 15:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 28 15.20 0 0 0.00 / 101.52 2 2
2 7 2002.64 44 14.38 2935 1857 1.86 / 103.37 2 2
3 13 1598.60 21 14.51 2459 749 2.61 / 104.12 2 2
4 13 914.04 21 14.73 1583 490 3.10 / 104.61 2 2
5 13 340.08 21 14.97 825 259 3.36 / 104.87 2 2
6 13 43.76 21 15.13 377 120 3.48 / 104.99 2 2
7 8 0.08 165 15.12 309 771 4.25 / 105.76 2 2
Average= 4.07
(KJ/cycle)

Cycle 24 GMT 3/ 4/2018 16:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 28 15.21 0 0 0.00 / 97.22 2 2
2 7 2001.92 44 14.39 2919 1848 1.85 / 99.07 2 2
3 13 1597.48 21 14.52 2460 750 2.60 / 99.82 2 2
4 13 1043.12 21 14.67 1755 541 3.14 / 100.36 2 2
5 13 332.24 21 14.98 815 256 3.40 / 100.62 2 2
6 13 42.64 21 15.14 380 121 3.52 / 100.74 2 2
7 8 0.08 165 15.12 311 776 4.29 / 101.52 2 2
Average= 4.06
(KJ/cycle)

Cycle 23 GMT 24/ 3/2018 17:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 28 15.21 0 0 0.00 / 92.87 2 2
2 7 2003.40 44 14.40 2908 1843 1.84 / 94.71 2 2
3 13 1728.08 21 14.48 2611 794 2.64 / 95.50 2 2
4 13 1011.32 21 14.69 1717 530 3.17 / 96.03 2 2
5 13 431.68 21 14.93 946 297 3.46 / 96.33 2 2
6 13 32.92 21 15.15 363 115 3.58 / 96.44 2 2
7 8 0.16 165 15.13 312 779 4.36 / 97.22 2 2
Average= 4.05
(KJ/cycle)

Cycle 22 GMT 14/ 3/2018 17:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 28 15.22 0 0 0.00 / 88.61 2 2
2 7 2005.64 44 14.40 2929 1856 1.86 / 90.47 2 2
3 13 1589.72 21 14.52 2446 746 2.60 / 91.21 2 2
4 13 897.76 21 14.75 1566 485 3.09 / 91.70 2 2
5 13 329.20 21 14.99 813 256 3.34 / 91.95 2 2
6 13 39.40 21 15.15 378 120 3.46 / 92.08 2 2
7 8 0.00 165 15.13 317 791 4.25 / 92.87 2 2
Average= 4.04
(KJ/cycle)

Cycle 21 GMT 4/ 3/2018 18:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 28 15.22 0 0 0.00 / 84.31 2 2
2 7 2003.00 44 14.41 2923 1853 1.85 / 86.16 2 2
3 13 1725.44 21 14.49 2603 792 2.65 / 86.95 2 2
4 13 1005.88 21 14.71 1696 524 3.17 / 87.48 2 2
5 13 301.84 21 15.02 763 241 3.41 / 87.72 2 2
6 13 37.32 21 15.16 364 116 3.53 / 87.83 2 2
7 8 0.24 165 15.13 312 779 4.30 / 88.61 2 2
Average= 4.03
(KJ/cycle)

Cycle 20 GMT 22/ 2/2018 19:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 28 15.22 0 0 0.00 / 80.03 2 2
2 7 2005.88 44 14.42 2907 1844 1.84 / 81.87 2 2
3 13 1612.60 21 14.53 2479 756 2.60 / 82.63 2 2
4 13 1024.84 21 14.70 1727 533 3.13 / 83.16 2 2
5 13 302.12 21 15.02 766 242 3.38 / 83.40 2 2
6 13 35.60 21 15.16 372 118 3.49 / 83.52 2 2
7 8 -0.04 165 15.13 315 786 4.28 / 84.31 2 2
Average= 4.01
(KJ/cycle)

Cycle 19 GMT 12/ 2/2018 19:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 28 15.23 0 0 0.00 / 75.76 2 2
2 7 2005.80 44 14.43 2917 1852 1.85 / 77.62 2 2
3 13 1599.84 21 14.54 2464 752 2.60 / 78.37 2 2
4 13 1017.96 21 14.72 1713 530 3.13 / 78.90 2 2
5 13 292.64 21 15.03 746 235 3.37 / 79.13 2 2
6 13 33.76 21 15.16 365 116 3.49 / 79.25 2 2
7 8 0.28 165 15.14 311 777 4.26 / 80.03 2 2
Average= 4.00
(KJ/cycle)

Cycle 18 GMT 2/ 2/2018 20:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 28 15.24 0 0 0.00 / 71.52 2 2
2 7 2002.64 44 14.43 2917 1852 1.85 / 73.37 2 2
3 13 1585.52 21 14.57 2421 741 2.59 / 74.11 2 2
4 13 1007.76 21 14.72 1704 527 3.12 / 74.64 2 2
5 13 293.40 21 15.03 755 238 3.36 / 74.87 2 2
6 13 31.72 21 15.17 359 114 3.47 / 74.99 2 2
7 8 0.20 165 15.14 311 777 4.25 / 75.76 2 2
Average= 3.99
(KJ/cycle)

Cycle 17 GMT 23/ 1/2018 21: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 28 15.24 0 0 0.00 / 67.24 2 2
2 7 2001.56 44 14.44 2914 1851 1.85 / 69.10 2 2
3 13 1593.88 21 14.55 2451 749 2.60 / 69.85 2 2
4 13 1023.32 21 14.72 1720 532 3.13 / 70.38 2 2
5 13 307.20 21 15.03 771 243 3.38 / 70.62 2 2
6 13 18.80 21 15.18 346 110 3.49 / 70.73 2 2
7 8 0.08 165 15.15 314 785 4.27 / 71.52 2 2
Average= 3.97
(KJ/cycle)

Cycle 16 GMT 13/ 1/2018 21:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 28 15.24 0 0 0.00 / 63.01 2 2
2 7 2003.24 44 14.45 2918 1855 1.86 / 64.86 2 2
3 13 1587.76 21 14.56 2451 749 2.60 / 65.61 2 2
4 13 889.96 21 14.78 1557 483 3.09 / 66.10 2 2
5 13 317.12 21 15.03 789 249 3.34 / 66.34 2 2
6 13 20.40 21 15.18 346 110 3.45 / 66.45 2 2
7 8 0.64 165 15.16 316 790 4.24 / 67.24 2 2
Average= 3.96
(KJ/cycle)

Cycle 15 GMT 3/ 1/2018 22:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 28 15.25 0 0 0.00 / 58.72 2 2
2 7 2002.84 44 14.45 2920 1857 1.86 / 60.57 2 2
3 13 1602.08 21 14.57 2458 752 2.61 / 61.33 2 2
4 13 1022.04 21 14.73 1718 531 3.14 / 61.86 2 2
5 13 298.08 21 15.04 759 240 3.38 / 62.10 2 2
6 13 16.08 21 15.19 342 109 3.49 / 62.21 2 2
7 8 0.04 165 15.15 320 800 4.29 / 63.01 2 2
Average= 3.94
(KJ/cycle)

Cycle 14 GMT 24/12/2017 23:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 28 15.25 0 0 0.00 / 54.44 2 2
2 7 2003.56 44 14.46 2924 1860 1.86 / 56.30 2 2
3 13 1587.56 21 14.57 2452 750 2.61 / 57.05 2 2
4 13 1013.20 21 14.74 1713 530 3.14 / 57.59 2 2
5 13 294.24 21 15.05 754 238 3.38 / 57.82 2 2
6 13 29.80 21 15.19 359 115 3.49 / 57.94 2 2
7 8 -0.24 165 15.16 312 780 4.27 / 58.72 2 2
Average= 3.91
(KJ/cycle)

Cycle 13 GMT 14/12/2017 23:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 31 15.25 0 0 0.00 / 50.29 2 2
2 3 879.96 -2 15.53 0 0 0.00 / 50.29 2 2
3 3 954.92 -1 15.55 0 0 0.00 / 50.29 2 2
4 7 2002.60 44 14.46 2918 1857 1.86 / 52.14 2 2
5 13 1588.52 21 14.58 2446 749 2.61 / 52.89 2 2
6 13 1006.32 21 14.75 1705 528 3.13 / 53.42 2 2
7 13 274.00 21 15.07 724 229 3.36 / 53.65 2 2
8 8 -0.08 165 15.17 317 793 4.16 / 54.44 2 2
Average= 3.89
(KJ/cycle)

Cycle 12 GMT 5/12/2017 0:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 28 15.25 0 0 0.00 / 46.09 2 2
2 5 1301.36 8 15.68 0 0 0.00 / 46.09 2 2
3 7 2007.76 44 14.46 2932 1865 1.87 / 47.96 2 2
4 13 1605.48 21 14.56 2482 759 2.62 / 48.72 2 2
5 13 1031.48 21 14.73 1734 536 3.16 / 49.25 2 2
6 13 301.28 21 15.05 767 242 3.40 / 49.50 2 2
7 8 0.24 165 15.17 316 791 4.19 / 50.29 2 2
Average= 3.87
(KJ/cycle)

Cycle 11 GMT 25/11/2017 0:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 28 15.26 0 0 0.00 / 41.86 2 2
2 5 1302.56 8 15.69 0 0 0.00 / 41.86 2 2
3 7 2006.92 44 14.46 2927 1862 1.86 / 43.72 2 2
4 13 1600.72 20 14.58 2478 723 2.58 / 44.44 2 2
5 13 1021.76 20 14.75 1727 509 3.09 / 44.95 2 2
6 13 312.40 20 15.05 780 235 3.33 / 45.18 2 2
7 13 37.48 20 15.19 375 114 3.44 / 45.30 2 2
8 8 -0.24 165 15.17 318 796 4.24 / 46.09 2 2
Average= 3.84
(KJ/cycle)

Cycle 10 GMT 15/11/2017 0:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 28 15.26 0 0 0.00 / 37.59 2 2
2 7 2003.88 44 14.49 2908 1854 1.85 / 39.44 2 2
3 13 1598.44 19 14.60 2468 685 2.54 / 40.13 2 2
4 13 1030.24 19 14.76 1738 487 3.03 / 40.62 2 2
5 13 593.40 19 14.93 1163 330 3.36 / 40.95 2 2
6 13 30.40 19 15.21 366 106 3.46 / 41.05 2 2
7 8 0.00 165 15.18 321 804 4.27 / 41.86 2 2
Average= 3.81
(KJ/cycle)

Cycle 9 GMT 5/11/2017 1:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 28 15.27 0 0 0.00 / 33.46 2 2
2 7 2004.48 44 14.50 2910 1857 1.86 / 35.32 2 2
3 13 1599.84 19 14.62 2464 684 2.54 / 36.00 2 2
4 13 913.44 19 14.81 1580 445 2.99 / 36.45 2 2
5 13 369.24 19 15.04 862 246 3.23 / 36.70 2 2
6 13 24.88 19 15.21 354 102 3.33 / 36.80 2 2
7 8 -0.04 165 15.18 316 791 4.13 / 37.59 2 2
Average= 3.76
(KJ/cycle)

Cycle 8 GMT 26/10/2017 1:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 28 15.27 0 0 0.00 / 29.18 2 2
2 7 2004.92 44 14.50 2904 1853 1.85 / 31.03 2 2
3 13 1589.32 25 14.59 2424 884 2.74 / 31.92 2 2
4 13 855.96 25 14.82 1501 556 3.29 / 32.47 2 2
5 13 131.88 25 15.16 510 193 3.49 / 32.66 2 2
6 8 0.60 165 15.18 319 799 4.29 / 33.46 2 2
Average= 3.72
(KJ/cycle)

Cycle 7 GMT 16/10/2017 2:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 27 15.27 0 0 0.00 / 24.90 2 2
2 7 2004.12 44 14.51 2898 1850 1.85 / 26.75 2 2
3 13 1589.32 25 14.60 2436 889 2.74 / 27.64 2 2
4 13 842.76 25 14.83 1480 549 3.29 / 28.19 2 2
5 13 123.04 25 15.17 498 189 3.48 / 28.38 2 2
6 8 0.04 165 15.19 319 800 4.28 / 29.18 2 2
Average= 3.65
(KJ/cycle)

Cycle 6 GMT 6/10/2017 3:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 27 15.27 0 0 0.00 / 20.64 2 2
2 3 1021.28 1 15.54 0 0 0.00 / 20.64 2 2
3 7 2005.32 44 14.51 2914 1860 1.86 / 22.50 2 2
4 13 1468.12 25 14.64 2277 833 2.69 / 23.34 2 2
5 13 767.36 25 14.86 1392 517 3.21 / 23.85 2 2
6 13 174.24 25 15.14 582 220 3.43 / 24.08 2 2
7 8 0.12 165 15.18 330 827 4.26 / 24.90 2 2
Average= 3.56
(KJ/cycle)

Cycle 5 GMT 26/ 9/2017 3:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 24 15.29 0 0 0.00 / 16.34 2 2
2 3 1075.00 2 15.55 0 0 0.00 / 16.34 2 2
3 3 1023.84 1 15.57 0 0 0.00 / 16.34 2 2
4 7 2004.36 46 14.52 2911 1944 1.94 / 18.29 2 2
5 13 1450.32 25 14.65 2269 831 2.78 / 19.12 2 2
6 13 743.24 25 14.88 1355 504 3.28 / 19.62 2 2
7 13 145.20 25 15.16 539 204 3.48 / 19.83 2 2
8 8 -0.08 165 15.18 327 819 4.30 / 20.64 2 2
Average= 3.44
(KJ/cycle)

Cycle 4 GMT 16/ 9/2017 4:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 26 15.26 0 0 0.00 / 12.59 2 2
2 7 1512.68 45 14.71 2343 1551 1.55 / 14.14 2 2
3 13 1386.36 25 14.73 2180 803 2.35 / 14.94 2 2
4 13 647.28 25 14.95 1228 459 2.81 / 15.40 2 2
5 13 42.44 25 15.23 378 144 2.96 / 15.55 2 2
6 8 0.00 165 15.20 317 795 3.75 / 16.34 2 2
Average= 3.27
(KJ/cycle)

Cycle 3 GMT 15/ 9/2017 5: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 26 15.27 0 0 0.00 / 8.45 2 2
2 7 1512.00 74 14.64 2334 2529 2.53 / 10.98 2 2
3 13 330.40 25 15.08 810 305 2.83 / 11.29 2 2
4 13 17.12 25 15.23 345 131 2.97 / 11.42 2 2
5 8 -0.12 240 15.18 321 1169 4.13 / 12.59 2 93
Average= 3.15
(KJ/cycle)

Cycle 2 GMT 14/ 9/2017 5:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 24 15.33 0 0 0.00 / 4.46 2 2
2 3 1056.48 1 15.56 0 0 0.00 / 4.46 2 2
3 7 1505.52 74 14.65 2321 2516 2.52 / 6.98 2 2
4 13 336.56 25 15.08 809 305 2.82 / 7.28 2 2
5 8 0.24 240 15.19 321 1170 3.99 / 8.45 2 2
Average= 2.82
(KJ/cycle)

Cycle 1 GMT 13/ 9/2017 6:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 24 15.53 0 0 0.00 / 1.47 2 2
2 3 1037.32 1 15.61 0 0 0.00 / 1.47 2 2
3 3 1020.20 1 15.62 0 0 0.00 / 1.47 2 2
4 7 997.40 74 14.89 1656 1825 1.82 / 3.30 2 2
5 8 0.08 240 15.26 319 1168 2.99 / 4.46 2 2
Average= 2.23
(KJ/cycle)

Cycle 0 GMT 12/ 9/2017 19:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.52 24 15.69 0 0 0.00 / 0.00 2 2
2 7 131.00 75 15.56 443 517 0.52 / 0.52 2 2
3 8 0.32 240 15.52 256 954 1.47 / 1.47 2 16
Average= 1.47
(KJ/cycle)