SIO Argo Site:
Pump Diagnostics Page   



Serial= 8378 WMO= 3901216

Return

←PreviousNext→

Cycle 318 GMT 31/ 1/2023 19:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 41 10.46 444 190 0.19 / 1576.83 2 2
2 3 1013.32 1 8.26 1674 14 0.20 / 1576.85 2 2
3 12 1132.88 186 7.34 1847 2522 2.73 / 1579.37 2 2
4 7 1129.56 23 7.38 1863 316 3.04 / 1579.68 2 2
5 13 181.28 38 10.11 551 212 3.25 / 1579.89 2 2
6 8 0.16 175 10.71 290 544 3.80 / 1580.44 2 17
Average= 4.95 (KJ/cycle)

Cycle 317 GMT 22/ 1/2023 1:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 39 10.49 446 182 0.18 / 1572.97 2 2
2 3 1052.12 2 8.03 1744 28 0.21 / 1573.00 2 2
3 3 1025.44 1 8.13 1694 14 0.22 / 1573.01 2 2
4 12 1139.40 186 7.41 1852 2553 2.78 / 1575.56 2 2
5 7 1134.28 23 7.50 1866 322 3.10 / 1575.88 2 2
6 13 175.60 38 10.14 556 214 3.31 / 1576.10 2 2
7 8 0.04 175 10.73 289 543 3.86 / 1576.64 2 14
Average= 4.96 (KJ/cycle)

Cycle 316 GMT 12/ 1/2023 7:23: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 41 10.55 439 190 0.19 / 1569.08 2 2
2 3 974.72 -1 10.55 439 0 0.00 / 1569.08 2 2
3 12 1165.40 186 7.46 1885 2616 2.81 / 1571.70 2 2
4 7 1157.92 23 7.46 1897 325 3.13 / 1572.02 2 2
5 13 187.60 38 10.14 565 218 3.35 / 1572.24 2 2
6 8 0.32 175 10.75 289 544 3.89 / 1572.79 2 12
Average= 4.96 (KJ/cycle)

Cycle 315 GMT 2/ 1/2023 13:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 41 10.56 435 188 0.19 / 1560.86 2 2
2 12 1115.96 10 7.84 1816 142 0.33 / 1561.00 2 2
3 12 2003.56 186 5.32 3243 3209 3.54 / 1564.21 2 2
4 7 1999.64 23 5.16 3237 384 3.92 / 1564.59 2 2
5 13 1910.48 38 5.91 2893 650 4.57 / 1565.24 2 2
6 13 1773.32 38 6.17 2739 642 5.22 / 1565.88 2 2
7 13 1628.00 38 6.57 2505 625 5.84 / 1566.51 2 2
8 13 1442.84 38 7.06 2250 604 6.44 / 1567.11 2 2
9 13 1231.04 38 7.49 1980 564 7.01 / 1567.68 2 2
10 13 796.96 38 8.54 1421 461 7.47 / 1568.14 2 2
11 13 155.44 38 10.25 534 208 7.68 / 1568.35 2 2
12 8 0.24 175 10.76 291 548 8.23 / 1568.89 2 12
Average= 4.96 (KJ/cycle)

Cycle 314 GMT 1/ 1/2023 9:22: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 41 10.56 434 188 0.19 / 1557.01 2 2
2 12 1107.52 186 7.86 1803 2636 2.82 / 1559.64 2 2
3 7 1102.20 23 7.88 1806 327 3.15 / 1559.97 2 2
4 13 59.28 38 10.58 375 151 3.30 / 1560.12 2 2
5 8 0.08 175 10.78 290 547 3.85 / 1560.67 2 12
Average= 4.95 (KJ/cycle)

Cycle 313 GMT 22/12/2022 15:34: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 43 10.58 445 202 0.20 / 1553.07 2 2
2 3 935.56 -1 10.58 445 0 0.00 / 1553.07 2 2
3 12 1128.48 186 7.90 1839 2702 2.90 / 1555.77 2 2
4 7 1122.04 23 7.91 1867 340 3.24 / 1556.11 2 2
5 13 64.00 38 10.59 389 157 3.40 / 1556.27 2 2
6 8 0.20 175 10.79 292 551 3.95 / 1556.82 2 8
Average= 4.96 (KJ/cycle)

Cycle 312 GMT 12/12/2022 21:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 37 10.59 453 177 0.18 / 1548.98 2 2
2 10 1033.04 4 8.57 1693 58 0.24 / 1549.04 2 2
3 3 1017.00 1 8.69 1695 15 0.25 / 1549.05 2 2
4 3 1012.92 1 8.69 1693 15 0.26 / 1549.07 2 2
5 12 1132.04 186 7.98 1845 2738 3.00 / 1551.80 2 2
6 7 1125.68 23 7.98 1852 340 3.34 / 1552.14 2 2
7 13 62.00 38 10.61 391 158 3.50 / 1552.30 2 2
8 8 0.20 175 10.80 299 565 4.07 / 1552.87 2 9
Average= 4.96 (KJ/cycle)

Cycle 311 GMT 3/12/2022 3:58: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 41 10.59 448 195 0.19 / 1542.42 2 2
2 3 965.92 -1 10.59 448 0 0.00 / 1542.42 2 2
3 3 1030.40 1 8.63 1711 15 0.21 / 1542.44 2 2
4 12 1139.88 10 8.20 1885 155 0.36 / 1542.59 2 2
5 12 2002.60 186 6.15 3061 3501 3.87 / 1546.09 2 2
6 7 1986.44 23 6.01 3037 420 4.29 / 1546.51 2 2
7 13 1553.20 38 7.18 2435 664 4.95 / 1547.18 2 2
8 13 1124.00 38 8.15 1857 575 5.52 / 1547.75 2 2
9 13 471.68 38 9.64 971 356 5.88 / 1548.11 2 2
10 13 47.40 38 10.70 358 146 6.03 / 1548.25 2 2
11 8 0.16 175 10.84 289 548 6.57 / 1548.80 2 9
Average= 4.96 (KJ/cycle)

Cycle 310 GMT 2/12/2022 0:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 41 10.58 460 200 0.20 / 1538.40 2 2
2 12 1124.60 186 8.13 1839 2781 2.98 / 1541.18 2 2
3 7 1117.04 23 8.17 1841 346 3.33 / 1541.52 2 2
4 13 29.52 38 10.74 341 139 3.47 / 1541.66 2 2
5 8 0.00 175 10.83 297 563 4.03 / 1542.23 2 10
Average= 4.96 (KJ/cycle)

Cycle 309 GMT 22/11/2022 7: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 82 10.60 447 389 0.39 / 1534.80 2 2
2 2 164.84 27 10.60 513 147 0.54 / 1534.95 2 2
3 3 878.72 -3 10.60 513 0 0.15 / 1534.95 2 2
4 3 1400.72 16 7.77 2187 272 0.81 / 1535.22 2 2
5 7 1435.80 23 7.65 2289 403 1.21 / 1535.62 2 2
6 13 1324.60 38 7.86 2140 639 1.85 / 1536.26 2 2
7 13 1150.60 38 8.26 1909 599 2.45 / 1536.86 2 2
8 13 935.56 38 8.69 1626 537 2.99 / 1537.40 2 2
9 13 200.28 38 10.32 600 235 3.22 / 1537.63 2 2
10 8 0.00 175 10.85 298 566 3.79 / 1538.20 2 21
Average= 4.96 (KJ/cycle)

Cycle 308 GMT 21/11/2022 16:10:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 10 1947.72 27 6.47 3009 526 0.53 / 1531.19 2 2
2 3 1945.88 37 6.29 3035 706 1.23 / 1531.90 2 2
3 3 1468.20 18 7.62 2290 314 1.55 / 1532.21 2 2
4 7 1160.76 23 8.14 1912 358 1.90 / 1532.57 2 2
5 13 1045.76 38 8.37 1762 560 2.46 / 1533.13 2 2
6 13 840.12 38 8.84 1486 499 2.96 / 1533.63 2 2
7 13 191.72 38 10.34 581 228 3.19 / 1533.86 2 2
8 8 0.04 175 10.86 292 555 3.75 / 1534.41 2 8
Average= 4.97 (KJ/cycle)

Cycle 307

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 41 10.50 433 186 0.19 / 1505.60 2 2
2 12 1108.12 10 7.70 1810 139 0.33 / 1505.74 2 2
3 12 2002.36 186 5.10 3063 2906 3.23 / 1508.64 2 2
4 7 2008.40 23 5.04 2799 324 3.56 / 1508.97 2 2
5 13 2059.48 38 5.14 3106 607 4.16 / 1509.57 2 2
6 13 2092.96 38 5.15 3159 618 4.78 / 1510.19 2 2
7 13 2117.56 38 5.16 3180 624 5.40 / 1510.82 2 2
8 13 2125.52 38 5.16 3199 627 6.03 / 1511.44 2 2
9 13 2113.68 38 5.17 3216 632 6.66 / 1512.07 2 2
10 13 2123.36 38 5.16 3238 635 7.30 / 1512.71 2 2
11 13 2120.24 38 5.17 3253 639 7.94 / 1513.35 2 2
12 13 2104.20 38 5.18 3263 642 8.58 / 1513.99 2 2
13 13 2110.28 38 5.18 3275 645 9.22 / 1514.64 2 2
14 13 2116.20 38 5.18 3291 648 9.87 / 1515.28 2 2
15 13 2115.44 38 5.19 3305 652 10.52 / 1515.94 2 2
16 13 2115.16 38 5.19 3315 654 11.18 / 1516.59 2 2
17 13 2116.40 38 5.19 3329 657 11.83 / 1517.25 2 2
18 13 2115.60 38 5.19 3341 659 12.49 / 1517.90 2 2
19 13 2114.76 38 5.20 3381 668 13.16 / 1518.57 2 2
20 13 2118.36 38 5.21 3392 672 13.83 / 1519.24 2 2
21 13 2115.96 38 5.22 3408 676 14.51 / 1519.92 2 2
22 13 2114.96 38 5.22 3421 679 15.19 / 1520.60 2 2
23 13 2114.88 528 5.00 2808 7413 22.60 / 1528.01 2 2
24 14 2112.52 140 5.63 3366 2653 25.25 / 1530.66 2 2
Average= 4.97 (KJ/cycle)

Cycle 306 GMT 19/11/2022 18:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 41 10.47 457 196 0.20 / 1501.78 2 2
2 12 1130.48 186 7.56 1834 2579 2.78 / 1504.36 2 2
3 7 1124.88 23 7.49 1843 317 3.09 / 1504.67 2 2
4 13 159.44 38 10.24 520 202 3.29 / 1504.88 2 2
5 8 0.24 175 10.75 284 534 3.83 / 1505.41 2 12
Average= 4.90 (KJ/cycle)

Cycle 305 GMT 10/11/2022 0:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 41 10.50 449 193 0.19 / 1497.92 2 2
2 12 1118.32 186 7.73 1838 2643 2.84 / 1500.56 2 2
3 7 1112.32 23 7.65 1826 321 3.16 / 1500.88 2 2
4 13 75.28 38 10.53 394 158 3.31 / 1501.04 2 2
5 8 -0.16 175 10.76 289 544 3.86 / 1501.58 2 9
Average= 4.91 (KJ/cycle)

Cycle 304 GMT 31/10/2022 7: 2:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 39 10.57 463 191 0.19 / 1493.93 2 2
2 3 1029.40 1 8.74 1715 15 0.21 / 1493.94 2 2
3 3 1020.48 1 8.75 1698 15 0.22 / 1493.96 2 2
4 12 1140.40 186 7.85 1868 2727 2.95 / 1496.68 2 2
5 7 1133.64 23 7.66 1854 327 3.27 / 1497.01 2 2
6 13 73.28 38 10.57 395 159 3.43 / 1497.17 2 2
7 8 0.28 175 10.78 293 553 3.99 / 1497.72 2 8
Average= 4.91 (KJ/cycle)

Cycle 303 GMT 21/10/2022 13: 1: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 40 10.44 440 184 0.18 / 1482.72 2 2
2 3 1032.28 1 8.21 1720 14 0.20 / 1482.73 2 2
3 3 1015.52 1 8.21 1678 14 0.21 / 1482.74 2 2
4 12 1140.08 10 7.66 1836 141 0.35 / 1482.89 2 2
5 12 2005.20 186 5.00 2708 2518 2.87 / 1485.40 2 2
6 7 2012.28 23 4.92 2345 265 3.14 / 1485.67 2 2
7 13 2064.72 38 5.18 3276 645 3.78 / 1486.31 2 2
8 13 2099.92 38 5.20 3368 666 4.45 / 1486.98 2 2
9 13 2115.80 38 5.35 3359 683 5.13 / 1487.66 2 2
10 13 2094.36 38 5.34 3399 690 5.82 / 1488.35 2 2
11 13 2066.68 38 5.67 3240 698 6.52 / 1489.05 2 2
12 13 1990.64 38 6.08 3031 700 7.22 / 1489.75 2 2
13 13 1879.44 38 6.36 2882 697 7.91 / 1490.45 2 2
14 13 1737.52 38 6.77 2686 691 8.60 / 1491.14 2 2
15 13 1551.60 38 7.18 2429 663 9.27 / 1491.80 2 2
16 13 1345.36 38 7.65 2167 630 9.90 / 1492.43 2 2
17 13 900.24 38 8.61 1577 516 10.41 / 1492.95 2 2
18 13 193.36 38 10.33 577 226 10.64 / 1493.17 2 2
19 8 0.20 175 10.81 298 564 11.20 / 1493.74 2 10
Average= 4.91 (KJ/cycle)

Cycle 302 GMT 20/10/2022 6:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 38 10.53 443 177 0.18 / 1478.98 2 2
2 3 1037.32 1 8.52 1693 14 0.19 / 1478.99 2 2
3 3 1021.48 1 8.58 1679 14 0.21 / 1479.01 2 2
4 12 1140.44 186 7.06 1828 2400 2.61 / 1481.41 2 2
5 7 1134.80 23 6.63 1808 276 2.88 / 1481.69 2 2
6 13 399.84 38 9.54 854 310 3.19 / 1481.99 2 2
7 8 0.12 175 10.71 287 538 3.73 / 1482.53 2 10
Average= 4.89 (KJ/cycle)

Cycle 301 GMT 10/10/2022 12: 7: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 39 10.90 449 191 0.19 / 1475.18 2 2
2 12 1117.88 186 7.56 1826 2568 2.76 / 1477.75 2 2
3 7 1112.84 23 7.11 1828 299 3.06 / 1478.05 2 2
4 13 161.16 38 10.32 527 207 3.26 / 1478.25 2 2
5 8 -0.12 175 10.75 292 549 3.81 / 1478.80 2 10
Average= 4.90 (KJ/cycle)

Cycle 300 GMT 30/ 9/2022 18:10: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 34 11.26 471 180 0.18 / 1471.11 2 2
2 3 1086.48 3 9.77 1811 53 0.23 / 1471.16 2 2
3 3 1028.00 1 9.91 1759 17 0.25 / 1471.18 2 2
4 12 1143.28 186 7.96 1865 2761 3.01 / 1473.94 2 2
5 7 1134.36 23 7.69 1867 330 3.34 / 1474.27 2 2
6 13 16.44 38 11.15 327 139 3.48 / 1474.41 2 2
7 8 0.12 175 11.09 298 578 4.06 / 1474.99 2 6
Average= 4.90 (KJ/cycle)

Cycle 299 GMT 21/ 9/2022 0:14: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 31 11.42 449 159 0.16 / 1463.89 2 2
2 10 1047.56 6 9.57 1762 101 0.26 / 1463.99 2 2
3 3 1050.84 2 9.67 1738 34 0.29 / 1464.02 2 2
4 3 1024.20 1 9.66 1731 17 0.31 / 1464.04 2 2
5 12 1138.48 10 9.12 1876 171 0.48 / 1464.21 2 2
6 12 2003.24 186 5.25 2520 2461 2.94 / 1466.67 2 2
7 7 1995.52 23 4.91 2289 258 3.20 / 1466.93 2 2
8 13 1900.72 38 7.33 2939 819 4.02 / 1467.75 2 2
9 13 1763.80 38 7.64 2745 797 4.82 / 1468.55 2 2
10 13 1565.96 38 8.18 2477 770 5.59 / 1469.32 2 2
11 13 1124.44 38 9.09 1878 649 6.24 / 1469.97 2 2
12 13 448.52 38 10.44 957 380 6.61 / 1470.35 2 2
13 8 0.20 175 11.38 294 586 7.20 / 1470.93 2 15
Average= 4.90 (KJ/cycle)

Cycle 298 GMT 19/ 9/2022 20:28: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 30 11.84 464 165 0.16 / 1459.60 2 2
2 10 1042.40 5 10.40 1774 92 0.26 / 1459.69 2 2
3 3 1059.36 2 10.30 1815 37 0.29 / 1459.73 2 2
4 3 1022.76 1 10.34 1733 18 0.31 / 1459.74 2 2
5 12 1129.48 186 5.48 1760 1794 2.11 / 1461.54 2 2
6 7 1138.96 23 6.57 1831 277 2.38 / 1461.81 2 2
7 13 1024.24 38 8.55 1733 563 2.95 / 1462.38 2 2
8 13 834.60 38 9.09 1481 512 3.46 / 1462.89 2 2
9 13 189.00 38 11.07 579 244 3.70 / 1463.13 2 2
10 8 0.16 175 11.55 296 598 4.30 / 1463.73 2 10
Average= 4.90 (KJ/cycle)

Cycle 297 GMT 10/ 9/2022 1:52:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 32 12.28 466 183 0.18 / 1455.57 2 2
2 3 1042.08 2 11.05 1799 40 0.22 / 1455.61 2 2
3 3 1016.88 1 10.75 1772 19 0.24 / 1455.63 2 2
4 12 1138.00 186 5.48 1804 1839 2.08 / 1457.46 2 2
5 7 1145.40 23 7.20 1847 306 2.39 / 1457.77 2 2
6 13 983.92 38 9.05 1683 579 2.97 / 1458.35 2 2
7 13 559.36 38 10.52 1107 443 3.41 / 1458.79 2 2
8 8 0.16 175 11.91 307 640 4.05 / 1459.43 2 13
Average= 4.90 (KJ/cycle)

Cycle 296 GMT 31/ 8/2022 7:25: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 30 13.07 480 188 0.19 / 1451.62 2 2
2 3 1044.64 2 11.88 1821 43 0.23 / 1451.66 2 2
3 3 1016.20 1 11.48 1779 20 0.25 / 1451.68 2 2
4 12 1135.84 186 7.04 1822 2386 2.64 / 1454.07 2 2
5 7 1132.20 23 8.91 1848 379 3.02 / 1454.45 2 2
6 13 171.40 38 12.09 571 262 3.28 / 1454.71 2 2
7 8 -0.04 175 12.32 313 675 3.95 / 1455.38 2 11
Average= 4.90 (KJ/cycle)

Cycle 295 GMT 21/ 8/2022 13:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 29 13.37 489 190 0.19 / 1444.61 2 2
2 3 1036.40 1 11.86 1807 21 0.21 / 1444.63 2 2
3 12 1121.24 10 11.40 1936 221 0.43 / 1444.85 2 2
4 12 2004.24 186 6.22 2927 3386 3.82 / 1448.24 2 2
5 7 1986.16 23 8.09 3098 576 4.39 / 1448.81 2 2
6 13 1549.96 38 9.93 2500 943 5.34 / 1449.76 2 2
7 13 878.48 38 11.31 1588 682 6.02 / 1450.44 2 2
8 13 171.80 38 12.81 576 280 6.30 / 1450.72 2 2
9 8 0.04 175 12.94 314 711 7.01 / 1451.43 2 10
Average= 4.90 (KJ/cycle)

Cycle 294 GMT 20/ 8/2022 8:58: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 30 13.70 467 192 0.19 / 1440.06 2 2
2 12 1122.64 186 4.97 1767 1633 1.83 / 1441.70 2 2
3 7 1143.88 23 8.74 1910 384 2.21 / 1442.08 2 2
4 13 1091.12 38 9.37 1846 657 2.87 / 1442.74 2 2
5 13 909.04 38 10.39 1607 634 3.50 / 1443.37 2 2
6 13 213.40 38 12.96 634 312 3.81 / 1443.69 2 2
7 8 0.24 175 13.33 314 732 4.55 / 1444.42 2 13
Average= 4.90 (KJ/cycle)

Cycle 293 GMT 10/ 8/2022 14:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 29 13.84 479 192 0.19 / 1435.91 2 2
2 12 1128.08 186 6.09 1793 2031 2.22 / 1437.94 2 2
3 7 1131.08 23 9.17 1852 391 2.61 / 1438.33 2 2
4 13 686.48 38 11.65 1307 579 3.19 / 1438.91 2 2
5 13 35.20 38 13.77 380 199 3.39 / 1439.11 2 3
6 8 -0.08 175 13.52 322 762 4.15 / 1439.87 2 22
Average= 4.90 (KJ/cycle)

Cycle 292 GMT 31/ 7/2022 20: 6: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 30 13.99 505 212 0.21 / 1431.77 2 2
2 3 966.16 -1 13.99 505 0 0.00 / 1431.77 2 2
3 3 1027.12 1 11.80 1772 21 0.23 / 1431.79 2 2
4 12 1135.16 186 7.14 1831 2432 2.66 / 1434.22 2 2
5 7 1134.64 23 9.62 1894 419 3.08 / 1434.64 2 2
6 13 157.92 38 13.63 568 294 3.38 / 1434.93 2 2
7 8 0.08 175 13.80 326 787 4.17 / 1435.72 2 10
Average= 4.90 (KJ/cycle)

Cycle 291 GMT 22/ 7/2022 2: 2: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 30 13.89 471 196 0.20 / 1424.05 2 2
2 3 964.92 -1 13.89 471 0 0.00 / 1424.05 2 2
3 3 1026.36 1 11.19 1776 20 0.22 / 1424.07 2 2
4 12 1134.04 10 11.15 1940 216 0.43 / 1424.29 2 2
5 12 2003.48 186 5.89 3090 3385 3.82 / 1427.67 2 2
6 7 1988.80 23 8.85 3110 633 4.45 / 1428.31 2 2
7 13 1791.24 38 9.98 2808 1065 5.52 / 1429.37 2 2
8 13 1311.76 38 11.56 2196 965 6.48 / 1430.34 2 2
9 13 309.08 38 13.59 776 401 6.88 / 1430.74 2 2
10 8 0.12 175 13.94 335 817 7.70 / 1431.55 2 13
Average= 4.90 (KJ/cycle)

Cycle 290 GMT 20/ 7/2022 22:43: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 30 13.95 468 196 0.20 / 1420.05 2 2
2 12 1117.84 186 6.52 1785 2165 2.36 / 1422.21 2 2
3 7 1119.20 23 9.22 1859 394 2.75 / 1422.61 2 2
4 13 415.24 38 12.92 924 454 3.21 / 1423.06 2 2
5 8 0.72 175 13.84 328 794 4.00 / 1423.86 2 11
Average= 4.89 (KJ/cycle)

Cycle 289 GMT 11/ 7/2022 4:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 29 14.02 484 197 0.20 / 1415.90 2 2
2 3 1018.92 1 11.19 1770 20 0.22 / 1415.92 2 2
3 3 1013.32 1 10.48 1760 18 0.24 / 1415.93 2 2
4 12 1132.76 186 7.15 1826 2428 2.66 / 1418.36 2 2
5 7 1127.24 23 9.44 1894 411 3.07 / 1418.77 2 2
6 13 179.40 38 13.59 600 310 3.38 / 1419.08 2 2
7 8 0.24 175 13.95 315 769 4.15 / 1419.85 2 13
Average= 4.90 (KJ/cycle)

Cycle 288 GMT 1/ 7/2022 10:39: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 30 14.08 493 208 0.21 / 1411.84 2 2
2 3 960.12 -1 14.08 493 0 0.00 / 1411.84 2 2
3 3 1018.04 1 11.11 1774 20 0.23 / 1411.85 2 2
4 12 1132.44 186 7.74 1830 2635 2.86 / 1414.49 2 2
5 7 1127.88 23 9.86 1849 419 3.28 / 1414.91 2 2
6 8 -0.16 175 13.94 324 790 4.07 / 1415.70 2 17
Average= 4.90 (KJ/cycle)

Cycle 287 GMT 21/ 6/2022 16:43: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 29 13.96 491 199 0.20 / 1405.05 2 2
2 3 1018.64 1 11.21 1761 20 0.22 / 1405.07 2 2
3 3 1017.12 1 10.96 1749 19 0.24 / 1405.09 2 2
4 12 1127.68 10 11.40 1909 218 0.46 / 1405.31 2 2
5 12 2002.40 186 6.97 3054 3959 4.41 / 1409.27 2 2
6 7 1981.00 23 9.17 3070 647 5.06 / 1409.91 2 2
7 13 741.36 38 12.92 1392 683 5.75 / 1410.60 2 2
8 13 50.00 38 14.07 410 219 5.96 / 1410.82 2 3
9 8 0.12 175 14.08 329 811 6.78 / 1411.63 2 17
Average= 4.90 (KJ/cycle)

Cycle 286 GMT 20/ 6/2022 13: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 30 14.01 480 202 0.20 / 1400.85 2 2
2 12 1113.36 186 7.36 1821 2493 2.69 / 1403.34 2 2
3 7 1109.84 23 9.58 1876 413 3.11 / 1403.76 2 2
4 13 151.96 38 13.71 562 293 3.40 / 1404.05 2 3
5 8 0.16 175 13.98 328 802 4.20 / 1404.85 2 14
Average= 4.89 (KJ/cycle)

Cycle 285 GMT 10/ 6/2022 19:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 29 13.97 501 203 0.20 / 1396.50 2 2
2 3 1025.48 1 11.68 1786 21 0.22 / 1396.52 2 2
3 12 1135.48 186 7.82 1839 2675 2.90 / 1399.20 2 2
4 7 1129.20 23 9.76 1895 425 3.32 / 1399.62 2 2
5 13 59.28 38 13.97 414 220 3.54 / 1399.84 2 3
6 8 0.12 175 14.02 329 807 4.35 / 1400.65 2 10
Average= 4.90 (KJ/cycle)

Cycle 284 GMT 1/ 6/2022 1:25: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 30 14.11 489 207 0.21 / 1392.19 2 2
2 3 969.48 -1 14.11 489 0 0.00 / 1392.19 2 2
3 3 1027.36 1 11.59 1784 21 0.23 / 1392.21 2 2
4 12 1141.52 186 8.12 1872 2827 3.05 / 1395.04 2 2
5 7 1134.28 23 9.97 1922 441 3.50 / 1395.48 2 2
6 8 0.24 175 13.99 335 820 4.32 / 1396.30 2 11
Average= 4.90 (KJ/cycle)

Cycle 283 GMT 22/ 5/2022 7:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 30 14.04 464 195 0.20 / 1385.35 2 2
2 3 970.96 -1 14.04 464 0 0.00 / 1385.35 2 2
3 3 1030.04 1 11.57 1792 21 0.22 / 1385.37 2 2
4 12 1137.52 10 11.40 1945 222 0.44 / 1385.59 2 2
5 12 2000.56 186 7.58 3055 4307 4.75 / 1389.90 2 2
6 7 1975.76 23 9.42 3058 663 5.41 / 1390.56 2 2
7 13 591.12 38 13.26 1179 594 6.00 / 1391.16 2 2
8 8 0.24 175 14.09 335 826 6.83 / 1391.98 2 21
Average= 4.90 (KJ/cycle)

Cycle 282 GMT 21/ 5/2022 4:39: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 30 13.98 496 208 0.21 / 1381.05 2 2
2 12 1118.64 186 7.78 1838 2660 2.87 / 1383.71 2 2
3 7 1113.20 23 9.80 1862 420 3.29 / 1384.13 2 2
4 13 56.32 38 13.98 416 221 3.51 / 1384.35 2 3
5 8 0.00 175 14.05 328 806 4.31 / 1385.15 2 18
Average= 4.89 (KJ/cycle)

Cycle 281 GMT 11/ 5/2022 10:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 29 14.03 484 197 0.20 / 1376.76 2 2
2 12 1132.76 186 8.16 1861 2825 3.02 / 1379.59 2 2
3 7 1125.04 23 9.91 1897 432 3.45 / 1380.02 2 2
4 8 0.04 175 14.02 333 817 4.27 / 1380.84 2 10
Average= 4.90 (KJ/cycle)

Cycle 280 GMT 1/ 5/2022 17: 6: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 30 14.13 472 200 0.20 / 1372.38 2 2
2 3 972.08 -1 14.13 472 0 0.00 / 1372.38 2 2
3 3 1029.72 1 11.80 1795 21 0.22 / 1372.40 2 2
4 12 1140.64 186 8.38 1860 2899 3.12 / 1375.30 2 2
5 7 1131.64 23 10.13 1903 443 3.56 / 1375.75 2 2
6 8 0.28 175 14.03 335 823 4.39 / 1376.57 2 17
Average= 4.90 (KJ/cycle)

Cycle 279 GMT 21/ 4/2022 23:29: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 30 14.01 492 207 0.21 / 1365.60 2 2
2 12 1106.00 10 11.61 1862 216 0.42 / 1365.81 2 2
3 12 1997.44 186 7.80 3052 4428 4.85 / 1370.24 2 2
4 7 1973.16 23 9.53 3078 675 5.53 / 1370.92 2 2
5 13 360.16 38 13.65 857 445 5.97 / 1371.36 2 2
6 8 0.12 175 14.12 332 820 6.79 / 1372.18 2 15
Average= 4.90 (KJ/cycle)

Cycle 278 GMT 20/ 4/2022 19:37: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 30 14.00 487 205 0.20 / 1361.21 2 2
2 12 1120.48 186 8.00 1841 2739 2.94 / 1363.95 2 2
3 7 1115.68 23 9.89 1875 427 3.37 / 1364.38 2 2
4 13 49.16 38 14.01 405 216 3.59 / 1364.60 2 4
5 8 0.00 175 14.08 323 796 4.38 / 1365.39 2 13
Average= 4.89 (KJ/cycle)

Cycle 277 GMT 11/ 4/2022 1:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 29 14.04 484 197 0.20 / 1356.87 2 2
2 3 1012.32 1 11.39 1773 20 0.22 / 1356.89 2 2
3 12 1128.96 186 8.31 1859 2873 3.09 / 1359.77 2 2
4 7 1118.20 23 10.02 1891 436 3.53 / 1360.20 2 2
5 8 0.16 175 14.05 328 806 4.33 / 1361.01 2 13
Average= 4.90 (KJ/cycle)

Cycle 276 GMT 1/ 4/2022 8:12: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 30 14.09 485 205 0.21 / 1352.43 2 2
2 3 964.00 -1 14.09 485 0 0.00 / 1352.43 2 2
3 3 1020.36 1 11.73 1766 21 0.23 / 1352.45 2 2
4 12 1138.56 186 8.55 1871 2975 3.20 / 1355.42 2 2
5 7 1128.56 23 10.21 1910 449 3.65 / 1355.87 2 2
6 8 0.36 175 14.09 327 806 4.46 / 1356.68 2 12
Average= 4.90 (KJ/cycle)

Cycle 275 GMT 22/ 3/2022 14:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 30 14.05 498 210 0.21 / 1345.54 2 2
2 12 1123.20 10 11.61 1873 217 0.43 / 1345.76 2 2
3 12 2001.32 186 7.98 3066 4551 4.98 / 1350.31 2 2
4 7 1976.88 23 9.63 3093 685 5.66 / 1351.00 2 2
5 13 301.44 38 13.73 772 403 6.07 / 1351.40 2 2
6 8 0.04 175 14.12 332 820 6.89 / 1352.22 2 18
Average= 4.90 (KJ/cycle)

Cycle 274 GMT 21/ 3/2022 11:26: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 30 14.01 488 205 0.21 / 1341.13 2 2
2 12 1121.72 186 8.28 1821 2804 3.01 / 1343.94 2 2
3 7 1109.56 23 10.00 1848 425 3.43 / 1344.36 2 2
4 13 2.68 38 14.11 327 175 3.61 / 1344.54 2 4
5 8 0.04 175 14.08 324 798 4.41 / 1345.33 2 22
Average= 4.89 (KJ/cycle)

Cycle 273 GMT 11/ 3/2022 17:47: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 29 14.00 486 197 0.20 / 1336.71 2 2
2 3 1025.52 1 11.99 1777 21 0.22 / 1336.73 2 2
3 12 1125.52 186 8.57 1846 2943 3.16 / 1339.67 2 2
4 7 1115.44 23 10.10 1890 439 3.60 / 1340.11 2 2
5 8 0.28 175 14.07 332 817 4.42 / 1340.93 2 14
Average= 4.89 (KJ/cycle)

Cycle 272 GMT 2/ 3/2022 0:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 30 14.08 486 205 0.21 / 1332.21 2 2
2 3 974.12 -1 14.08 486 0 0.00 / 1332.21 2 2
3 3 1029.44 1 11.93 1794 21 0.23 / 1332.24 2 2
4 12 1140.76 186 8.67 1867 3011 3.24 / 1335.25 2 2
5 7 1131.28 23 10.28 1904 450 3.69 / 1335.70 2 2
6 8 0.16 175 14.09 329 811 4.50 / 1336.51 2 13
Average= 4.90 (KJ/cycle)

Cycle 271 GMT 20/ 2/2022 6:36: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 30 14.03 486 205 0.20 / 1325.15 2 2
2 12 1106.76 10 11.52 1913 220 0.42 / 1325.37 2 2
3 12 2000.76 186 8.20 3055 4659 5.08 / 1330.03 2 2
4 7 1976.24 23 9.83 3039 687 5.77 / 1330.72 2 2
5 13 136.60 38 13.95 544 288 6.06 / 1331.01 2 3
6 13 3.88 38 14.15 340 183 6.24 / 1331.19 2 4
7 8 0.12 175 14.13 331 818 7.06 / 1332.01 2 23
Average= 4.90 (KJ/cycle)

Cycle 270 GMT 19/ 2/2022 3:14: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 29 13.99 499 202 0.20 / 1320.64 2 2
2 12 1130.60 186 8.27 1857 2856 3.06 / 1323.50 2 2
3 7 1121.12 23 10.06 1897 439 3.50 / 1323.94 2 2
4 13 20.64 38 14.07 366 196 3.69 / 1324.13 2 3
5 8 -0.08 175 14.06 331 814 4.51 / 1324.95 2 20
Average= 4.89 (KJ/cycle)

Cycle 269 GMT 9/ 2/2022 9:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 30 13.98 500 210 0.21 / 1316.02 2 2
2 12 1129.48 186 8.59 1866 2981 3.19 / 1319.00 2 2
3 7 1120.64 23 10.14 1903 444 3.63 / 1319.44 2 2
4 13 14.92 38 14.08 355 190 3.82 / 1319.63 2 3
5 8 0.08 175 14.08 328 808 4.63 / 1320.44 2 22
Average= 4.89 (KJ/cycle)

Cycle 268 GMT 30/ 1/2022 16: 3: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 30 14.03 497 209 0.21 / 1311.52 2 2
2 12 1110.48 186 8.83 1836 3015 3.22 / 1314.54 2 2
3 7 1100.52 23 10.36 1873 446 3.67 / 1314.98 2 2
4 8 0.24 175 14.08 334 823 4.49 / 1315.81 2 18
Average= 4.89 (KJ/cycle)

Cycle 267 GMT 20/ 1/2022 22:34: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 30 13.96 477 200 0.20 / 1304.61 2 2
2 12 1107.04 10 11.60 1885 219 0.42 / 1304.83 2 2
3 12 1988.52 186 8.25 3049 4679 5.10 / 1309.51 2 2
4 7 1963.16 23 9.85 3090 700 5.80 / 1310.21 2 2
5 13 131.56 38 13.96 524 278 6.08 / 1310.48 2 3
6 8 0.04 175 14.11 336 830 6.90 / 1311.31 2 13
Average= 4.89 (KJ/cycle)

Cycle 266 GMT 19/ 1/2022 18:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 31 13.97 486 210 0.21 / 1300.24 2 2
2 3 960.84 -1 13.97 486 0 0.00 / 1300.24 2 2
3 3 1016.52 1 11.56 1768 20 0.23 / 1300.26 2 2
4 12 1143.40 186 8.27 1877 2887 3.12 / 1303.14 2 2
5 7 1136.80 23 10.09 1918 445 3.56 / 1303.59 2 2
6 8 0.20 175 14.07 333 820 4.38 / 1304.41 2 10
Average= 4.89 (KJ/cycle)

Cycle 265 GMT 10/ 1/2022 1: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 30 14.07 477 201 0.20 / 1295.87 2 2
2 12 1115.76 170 8.64 1842 2706 2.91 / 1298.57 2 2
3 7 1109.72 23 10.15 1891 441 3.35 / 1299.01 2 2
4 13 21.28 38 14.05 364 194 3.54 / 1299.21 2 3
5 8 0.16 175 14.08 332 818 4.36 / 1300.03 2 20
Average= 4.89 (KJ/cycle)

Cycle 264 GMT 31/12/2021 7:22: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 30 14.09 497 210 0.21 / 1291.41 2 2
2 3 971.24 -1 14.09 497 0 0.00 / 1291.41 2 2
3 3 1038.32 2 12.10 1795 43 0.25 / 1291.45 2 2
4 12 1133.56 170 8.77 1855 2766 3.02 / 1294.22 2 2
5 7 1125.64 23 10.29 1903 450 3.47 / 1294.67 2 2
6 13 23.88 38 14.07 363 194 3.66 / 1294.86 2 3
7 8 -0.08 175 14.09 325 801 4.46 / 1295.66 2 22
Average= 4.89 (KJ/cycle)

Cycle 263 GMT 21/12/2021 13:35:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 30 13.93 490 205 0.20 / 1284.73 2 2
2 12 1121.04 10 11.66 1923 224 0.43 / 1284.95 2 2
3 12 1992.72 170 8.29 3055 4305 4.73 / 1289.26 2 2
4 7 1969.92 23 9.91 3072 700 5.43 / 1289.96 2 2
5 13 315.40 38 13.71 796 415 5.85 / 1290.37 2 3
6 8 0.12 175 14.12 334 825 6.67 / 1291.20 2 12
Average= 4.89 (KJ/cycle)

Cycle 262 GMT 20/12/2021 9:45: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 28 13.98 486 190 0.19 / 1280.38 2 2
2 3 1044.20 2 12.13 1801 44 0.23 / 1280.43 2 2
3 3 1016.08 1 11.40 1786 20 0.25 / 1280.45 2 2
4 12 1138.84 170 8.35 1848 2623 2.88 / 1283.07 2 2
5 7 1133.96 23 10.11 1888 439 3.32 / 1283.51 2 2
6 13 28.12 38 14.03 379 202 3.52 / 1283.71 2 3
7 8 0.32 175 14.06 331 814 4.33 / 1284.52 2 17
Average= 4.88 (KJ/cycle)

Cycle 261 GMT 10/12/2021 15:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 30 13.93 494 206 0.21 / 1276.00 2 2
2 12 1136.24 170 8.59 1870 2731 2.94 / 1278.73 2 2
3 7 1129.00 23 10.13 1915 446 3.38 / 1279.17 2 2
4 13 25.64 38 14.03 377 201 3.58 / 1279.37 2 4
5 8 0.12 175 14.06 332 817 4.40 / 1280.19 2 16
Average= 4.89 (KJ/cycle)

Cycle 260 GMT 30/11/2021 22: 9: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 30 14.07 492 208 0.21 / 1271.72 2 2
2 12 1121.56 170 8.78 1873 2796 3.00 / 1274.52 2 2
3 7 1114.44 23 10.34 1895 451 3.45 / 1274.97 2 2
4 8 0.04 175 14.08 334 823 4.28 / 1275.79 2 10
Average= 4.89 (KJ/cycle)

Cycle 259 GMT 21/11/2021 4:19:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 30 13.92 495 207 0.21 / 1265.19 2 2
2 12 1112.36 10 11.60 1895 220 0.43 / 1265.41 2 2
3 12 2002.00 170 8.13 3063 4233 4.66 / 1269.64 2 2
4 7 1981.24 23 9.91 3066 699 5.36 / 1270.34 2 2
5 13 209.64 38 13.84 655 344 5.70 / 1270.69 2 2
6 8 0.12 175 14.11 335 827 6.53 / 1271.51 2 12
Average= 4.89 (KJ/cycle)

Cycle 258 GMT 20/11/2021 0:59: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 30 13.98 487 204 0.20 / 1260.91 2 2
2 3 974.28 -1 13.98 487 0 0.00 / 1260.91 2 2
3 12 1158.84 170 8.03 1887 2576 2.78 / 1263.49 2 2
4 7 1154.48 23 10.01 1928 444 3.22 / 1263.93 2 2
5 13 80.12 38 13.92 459 243 3.47 / 1264.17 2 3
6 8 0.04 175 14.05 330 811 4.28 / 1264.98 2 19
Average= 4.88 (KJ/cycle)

Cycle 257 GMT 10/11/2021 7: 2:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 30 13.95 487 204 0.20 / 1256.68 2 2
2 12 1113.00 170 8.36 1842 2618 2.82 / 1259.30 2 2
3 7 1108.28 23 10.15 1873 437 3.26 / 1259.74 2 2
4 13 26.60 38 14.03 370 197 3.46 / 1259.93 2 3
5 8 0.04 175 14.06 313 770 4.23 / 1260.70 2 15
Average= 4.89 (KJ/cycle)

Cycle 256 GMT 31/10/2021 13:13: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 30 13.97 499 209 0.21 / 1252.79 2 2
2 12 1114.44 132 8.62 1847 2102 2.31 / 1254.90 2 2
3 7 1113.36 23 10.29 1877 444 2.75 / 1255.34 2 2
4 13 190.88 38 13.80 617 324 3.08 / 1255.66 2 2
5 8 0.00 175 14.07 331 815 3.89 / 1256.48 2 11
Average= 4.89 (KJ/cycle)

Cycle 255 GMT 21/10/2021 19:10:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 30 13.88 502 209 0.21 / 1246.87 2 2
2 12 1128.04 10 11.46 1945 223 0.43 / 1247.10 2 2
3 12 2005.96 132 8.05 3086 3279 3.71 / 1250.37 2 2
4 7 1991.64 23 9.95 3086 706 4.42 / 1251.08 2 2
5 13 752.28 38 13.14 1413 706 5.12 / 1251.79 2 2
6 8 0.08 175 14.13 323 799 5.92 / 1252.59 2 11
Average= 4.89 (KJ/cycle)

Cycle 254 GMT 20/10/2021 15: 8: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 30 13.91 493 206 0.21 / 1243.04 2 2
2 12 1106.20 132 7.87 1820 1891 2.10 / 1244.93 2 2
3 7 1107.68 23 10.03 1889 436 2.53 / 1245.36 2 2
4 13 425.08 38 13.37 956 486 3.02 / 1245.85 2 2
5 8 0.08 175 14.04 332 816 3.83 / 1246.66 2 15
Average= 4.89 (KJ/cycle)

Cycle 253 GMT 10/10/2021 21: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 29 13.90 499 201 0.20 / 1239.03 2 2
2 12 1127.64 132 8.30 1863 2041 2.24 / 1241.08 2 2
3 7 1128.00 23 10.13 1911 445 2.69 / 1241.52 2 2
4 13 423.40 38 13.40 946 482 3.17 / 1242.00 2 2
5 8 0.08 175 14.03 337 827 4.00 / 1242.83 2 10
Average= 4.89 (KJ/cycle)

Cycle 252 GMT 1/10/2021 3: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 29 13.99 497 202 0.20 / 1235.14 2 2
2 12 1115.20 132 8.78 1849 2143 2.34 / 1237.28 2 2
3 7 1113.12 23 10.38 1892 452 2.80 / 1237.73 2 2
4 13 177.00 35 13.81 594 287 3.08 / 1238.02 2 3
5 8 -0.08 175 14.05 332 816 3.90 / 1238.83 2 13
Average= 4.90 (KJ/cycle)

Cycle 251 GMT 21/ 9/2021 8:59: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 29 13.88 498 200 0.20 / 1228.97 2 2
2 12 1117.76 10 11.62 1926 224 0.42 / 1229.19 2 2
3 12 1999.52 132 8.36 3078 3397 3.82 / 1232.59 2 2
4 7 1983.00 23 10.01 3095 713 4.53 / 1233.30 2 2
5 13 689.76 35 13.26 1332 618 5.15 / 1233.92 2 2
6 13 32.24 35 14.07 391 193 5.34 / 1234.11 2 3
7 8 0.04 175 14.08 334 823 6.17 / 1234.93 2 16
Average= 4.90 (KJ/cycle)

Cycle 250 GMT 20/ 9/2021 5: 1: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 28 13.96 494 193 0.19 / 1225.09 2 2
2 3 1047.72 2 11.97 1824 44 0.24 / 1225.13 2 2
3 12 1137.76 132 7.90 1833 1911 2.15 / 1227.04 2 2
4 7 1140.12 23 10.11 1896 441 2.59 / 1227.48 2 2
5 13 461.44 35 13.36 1002 469 3.06 / 1227.95 2 2
6 8 0.44 175 14.04 331 813 3.87 / 1228.77 2 7
Average= 4.90 (KJ/cycle)

Cycle 249 GMT 10/ 9/2021 10:51: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 29 13.88 493 198 0.20 / 1221.16 2 2
2 12 1129.24 132 8.40 1846 2047 2.25 / 1223.21 2 2
3 7 1128.80 23 10.24 1921 452 2.70 / 1223.66 2 2
4 13 387.80 35 13.48 894 422 3.12 / 1224.08 2 2
5 8 0.00 175 14.02 331 812 3.93 / 1224.90 2 13
Average= 4.90 (KJ/cycle)

Cycle 248 GMT 31/ 8/2021 16:53: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 29 14.04 499 203 0.20 / 1217.32 2 2
2 12 1124.76 126 8.89 1858 2081 2.28 / 1219.41 2 2
3 7 1123.96 23 10.44 1902 457 2.74 / 1219.86 2 2
4 13 195.84 35 13.81 616 298 3.04 / 1220.16 2 2
5 8 0.16 175 14.04 327 803 3.84 / 1220.96 2 12
Average= 4.90 (KJ/cycle)

Cycle 247 GMT 21/ 8/2021 22:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 31 13.87 494 212 0.21 / 1211.22 2 2
2 3 961.64 -1 13.87 494 0 0.00 / 1211.22 2 2
3 12 1118.56 10 11.75 1896 223 0.44 / 1211.44 2 2
4 12 2001.04 126 8.63 3087 3357 3.79 / 1214.80 2 2
5 7 1985.28 23 10.14 3094 722 4.51 / 1215.52 2 2
6 13 684.28 35 13.29 1321 614 5.13 / 1216.14 2 2
7 13 1.60 35 14.11 346 171 5.30 / 1216.31 2 3
8 8 0.08 175 14.08 331 816 6.11 / 1217.12 2 18
Average= 4.91 (KJ/cycle)

Cycle 246 GMT 20/ 8/2021 19: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 30 13.84 510 212 0.21 / 1207.14 2 2
2 3 975.36 -1 13.84 510 0 0.00 / 1207.14 2 2
3 12 1158.56 126 7.65 1869 1802 2.01 / 1208.94 2 2
4 7 1161.20 23 10.16 1947 455 2.47 / 1209.39 2 2
5 13 716.40 35 12.96 1366 620 3.09 / 1210.01 2 2
6 13 17.84 35 14.04 365 179 3.27 / 1210.19 2 3
7 8 -0.20 175 14.00 333 816 4.08 / 1211.01 2 12
Average= 4.90 (KJ/cycle)

Cycle 245 GMT 11/ 8/2021 1: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 29 13.91 480 194 0.19 / 1203.23 2 2
2 12 1128.48 126 8.39 1863 1969 2.16 / 1205.20 2 2
3 7 1129.12 23 10.33 1920 456 2.62 / 1205.65 2 2
4 13 426.52 35 13.43 964 453 3.07 / 1206.10 2 2
5 8 0.36 175 14.02 334 819 3.89 / 1206.92 2 14
Average= 4.91 (KJ/cycle)

Cycle 244 GMT 1/ 8/2021 6:56: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 29 14.04 496 202 0.20 / 1199.35 2 2
2 3 1012.88 1 11.81 1777 21 0.22 / 1199.37 2 2
3 12 1140.36 126 8.87 1870 2090 2.31 / 1201.46 2 2
4 7 1140.88 23 10.49 1925 464 2.78 / 1201.92 2 2
5 13 189.32 35 13.81 617 298 3.08 / 1202.22 2 3
6 8 0.08 175 14.04 330 811 3.89 / 1203.03 2 9
Average= 4.91 (KJ/cycle)

Cycle 243 GMT 22/ 7/2021 12:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 29 13.94 503 203 0.20 / 1193.16 2 2
2 3 1028.92 1 11.84 1791 21 0.22 / 1193.18 2 2
3 12 1133.72 10 11.70 1937 227 0.45 / 1193.41 2 2
4 12 2003.72 126 8.73 3107 3418 3.87 / 1196.83 2 2
5 7 1989.40 23 10.25 3095 730 4.60 / 1197.56 2 2
6 13 693.04 35 13.29 1340 623 5.22 / 1198.18 2 2
7 13 5.08 35 14.13 334 165 5.39 / 1198.34 2 5
8 8 0.20 175 14.10 325 802 6.19 / 1199.15 2 14
Average= 4.91 (KJ/cycle)

Cycle 242 GMT 21/ 7/2021 9:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 30 13.91 492 205 0.21 / 1189.30 2 2
2 12 1118.80 126 7.77 1835 1797 2.00 / 1191.10 2 2
3 7 1122.32 23 10.29 1917 454 2.46 / 1191.55 2 2
4 13 666.28 35 13.08 1297 594 3.05 / 1192.14 2 2
5 8 0.16 175 14.04 331 813 3.86 / 1192.96 2 11
Average= 4.91 (KJ/cycle)

Cycle 241 GMT 11/ 7/2021 15:30: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 29 13.92 480 194 0.19 / 1185.46 2 2
2 12 1115.92 126 8.21 1859 1923 2.12 / 1187.39 2 2
3 7 1116.64 23 10.46 1898 457 2.57 / 1187.84 2 2
4 13 417.28 35 13.51 943 446 3.02 / 1188.29 2 2
5 8 0.32 175 14.04 328 806 3.83 / 1189.09 2 17
Average= 4.91 (KJ/cycle)

Cycle 240 GMT 1/ 7/2021 21:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 30 13.98 481 202 0.20 / 1181.39 2 2
2 3 964.88 -1 13.98 481 0 0.00 / 1181.39 2 2
3 3 1018.72 1 12.07 1764 21 0.22 / 1181.41 2 2
4 12 1150.60 85 8.82 1878 1408 1.63 / 1182.82 2 2
5 7 1155.12 23 10.57 1956 476 2.11 / 1183.30 2 2
6 13 939.24 35 12.79 1675 750 2.86 / 1184.05 2 2
7 13 103.00 35 13.95 486 237 3.09 / 1184.29 2 3
8 13 17.24 35 14.08 363 179 3.27 / 1184.46 2 3
9 8 0.08 175 14.03 328 805 4.08 / 1185.27 2 16
Average= 4.92 (KJ/cycle)

Cycle 239 GMT 22/ 6/2021 3:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 30 13.88 481 200 0.20 / 1175.88 2 2
2 3 967.44 -1 13.88 481 0 0.00 / 1175.88 2 2
3 3 1024.28 1 11.88 1773 21 0.22 / 1175.90 2 2
4 12 1133.40 10 11.85 1913 227 0.45 / 1176.12 2 2
5 12 2000.12 85 9.34 3076 2442 2.89 / 1178.57 2 2
6 7 1990.20 23 10.30 3117 738 3.63 / 1179.30 2 2
7 13 1015.60 35 12.95 1781 807 4.44 / 1180.11 2 2
8 13 139.60 35 13.95 545 266 4.70 / 1180.38 2 3
9 8 0.16 175 14.09 330 814 5.52 / 1181.19 2 13
Average= 4.92 (KJ/cycle)

Cycle 238 GMT 20/ 6/2021 23:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 30 13.92 486 203 0.20 / 1171.99 2 2
2 12 1114.96 85 7.48 1793 1140 1.34 / 1173.13 2 2
3 7 1122.92 23 10.34 1914 455 1.80 / 1173.59 2 2
4 13 967.28 35 12.58 1714 755 2.55 / 1174.34 2 2
5 13 289.92 35 13.68 756 362 2.91 / 1174.71 2 2
6 13 7.76 35 14.06 346 170 3.09 / 1174.88 2 2
7 8 0.00 175 14.02 326 800 3.88 / 1175.68 2 15
Average= 4.92 (KJ/cycle)

Cycle 237 GMT 11/ 6/2021 5: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 30 13.88 483 201 0.20 / 1168.28 2 2
2 12 1115.80 85 8.24 1813 1270 1.47 / 1169.55 2 2
3 7 1121.68 23 10.47 1908 459 1.93 / 1170.01 2 2
4 13 928.40 35 12.70 1657 737 2.67 / 1170.74 2 2
5 13 118.72 35 13.91 512 249 2.92 / 1170.99 2 3
6 8 -0.04 175 14.04 325 799 3.71 / 1171.79 2 13
Average= 4.92 (KJ/cycle)

Cycle 236 GMT 1/ 6/2021 10:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 30 14.00 470 197 0.20 / 1164.48 2 2
2 12 1119.24 80 9.06 1857 1346 1.54 / 1165.83 2 2
3 7 1123.88 23 10.66 1912 469 2.01 / 1166.30 2 2
4 13 923.16 35 12.83 1647 740 2.75 / 1167.04 2 2
5 13 95.52 35 13.95 478 233 2.99 / 1167.27 2 3
6 8 0.12 175 14.05 328 806 3.79 / 1168.08 2 15
Average= 4.93 (KJ/cycle)

Cycle 235 GMT 22/ 5/2021 16:32: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 30 13.93 482 201 0.20 / 1159.09 2 2
2 12 1114.88 9 11.90 1884 202 0.40 / 1159.29 2 2
3 12 2003.48 80 9.38 3102 2328 2.73 / 1161.62 2 2
4 7 1996.04 23 10.24 3126 736 3.47 / 1162.35 2 2
5 13 1051.72 35 12.93 1833 830 4.30 / 1163.18 2 2
6 13 168.36 35 13.91 583 284 4.58 / 1163.47 2 3
7 8 0.04 175 14.10 332 819 5.40 / 1164.28 2 16
Average= 4.93 (KJ/cycle)

Cycle 234 GMT 21/ 5/2021 13: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 30 13.95 472 198 0.20 / 1155.41 2 2
2 12 1111.80 80 7.68 1774 1090 1.29 / 1156.50 2 2
3 7 1119.12 23 10.44 1886 453 1.74 / 1156.95 2 2
4 13 969.20 35 12.63 1717 759 2.50 / 1157.71 2 2
5 13 287.60 35 13.68 758 363 2.86 / 1158.07 2 2
6 8 0.36 175 14.03 331 813 3.67 / 1158.88 2 13
Average= 4.93 (KJ/cycle)

Cycle 233 GMT 11/ 5/2021 18:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 30 13.94 473 198 0.20 / 1151.67 2 2
2 12 1110.80 80 8.38 1813 1215 1.41 / 1152.89 2 2
3 7 1116.76 23 10.55 1905 462 1.88 / 1153.35 2 2
4 13 935.04 35 12.74 1669 744 2.62 / 1154.09 2 2
5 13 207.16 35 13.79 641 309 2.93 / 1154.40 2 3
6 8 0.08 175 14.04 328 806 3.73 / 1155.21 2 15
Average= 4.94 (KJ/cycle)

Cycle 232 GMT 2/ 5/2021 0:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 30 13.98 491 206 0.21 / 1147.86 2 2
2 12 1120.52 80 9.22 1867 1377 1.58 / 1149.24 2 2
3 7 1126.16 23 10.79 1906 473 2.06 / 1149.71 2 2
4 13 923.48 35 12.90 1641 741 2.80 / 1150.45 2 2
5 13 90.36 35 13.97 471 230 3.03 / 1150.68 2 3
6 8 0.08 175 14.07 323 795 3.82 / 1151.48 2 17
Average= 4.94 (KJ/cycle)

Cycle 231 GMT 22/ 4/2021 6:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 30 13.93 492 206 0.21 / 1142.46 2 2
2 12 1109.96 9 11.95 1907 205 0.41 / 1142.67 2 2
3 12 2002.12 80 9.61 3084 2371 2.78 / 1145.04 2 2
4 7 1994.00 23 10.29 3114 737 3.52 / 1145.78 2 2
5 13 1024.48 35 12.97 1788 812 4.33 / 1146.59 2 2
6 13 144.36 35 13.94 549 268 4.60 / 1146.85 2 3
7 8 0.12 175 14.11 323 798 5.40 / 1147.65 2 17
Average= 4.95 (KJ/cycle)

Cycle 230 GMT 21/ 4/2021 3: 3: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 30 13.98 489 205 0.21 / 1138.55 2 2
2 12 1122.84 80 7.63 1819 1110 1.32 / 1139.67 2 2
3 7 1130.76 23 10.47 1935 466 1.78 / 1140.13 2 2
4 13 990.32 35 12.65 1746 773 2.55 / 1140.90 2 2
5 13 326.88 35 13.65 805 385 2.94 / 1141.29 2 2
6 13 13.36 35 14.06 349 172 3.11 / 1141.46 2 3
7 8 0.16 175 14.04 324 796 3.91 / 1142.26 2 21
Average= 4.94 (KJ/cycle)

Cycle 229 GMT 11/ 4/2021 8:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 30 13.93 486 203 0.20 / 1134.77 2 2
2 12 1124.24 80 8.50 1846 1255 1.46 / 1136.02 2 2
3 7 1130.28 23 10.62 1934 472 1.93 / 1136.49 2 2
4 13 939.80 35 12.79 1671 748 2.68 / 1137.24 2 2
5 13 205.92 35 13.81 634 306 2.99 / 1137.55 2 2
6 8 0.08 175 14.05 326 802 3.79 / 1138.35 2 14
Average= 4.95 (KJ/cycle)

Cycle 228 GMT 1/ 4/2021 14:26: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 30 13.92 492 205 0.21 / 1130.93 2 2
2 12 1117.48 80 9.41 1843 1387 1.59 / 1132.32 2 2
3 7 1121.48 23 10.78 1910 474 2.07 / 1132.79 2 2
4 13 906.40 35 12.94 1623 735 2.80 / 1133.53 2 2
5 13 91.08 35 13.98 474 232 3.03 / 1133.76 2 3
6 8 0.12 175 14.06 327 805 3.84 / 1134.56 2 14
Average= 4.95 (KJ/cycle)

Cycle 227 GMT 22/ 3/2021 20:22: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 29 13.96 497 201 0.20 / 1125.45 2 2
2 12 1125.88 9 11.96 1965 212 0.41 / 1125.66 2 2
3 12 2001.80 80 9.73 3106 2418 2.83 / 1128.08 2 2
4 7 1993.44 23 10.38 3098 740 3.57 / 1128.82 2 2
5 13 1033.08 35 12.96 1808 820 4.39 / 1129.64 2 2
6 13 145.88 35 13.92 552 269 4.66 / 1129.91 2 3
7 8 0.00 175 14.10 331 817 5.48 / 1130.73 2 20
Average= 4.96 (KJ/cycle)

Cycle 226 GMT 21/ 3/2021 17: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 30 13.89 492 205 0.21 / 1121.68 2 2
2 12 1121.64 80 7.82 1823 1140 1.35 / 1122.82 2 2
3 7 1130.52 23 10.59 1924 469 1.81 / 1123.29 2 2
4 13 975.96 35 12.73 1735 773 2.59 / 1124.06 2 2
5 13 288.56 35 13.69 756 362 2.95 / 1124.42 2 2
6 8 0.12 175 14.02 336 824 3.77 / 1125.25 2 24
Average= 4.96 (KJ/cycle)

Cycle 225 GMT 11/ 3/2021 22:47: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 30 14.00 483 203 0.20 / 1117.86 2 2
2 12 1117.28 80 8.72 1836 1281 1.48 / 1119.14 2 2
3 7 1122.84 23 10.71 1927 475 1.96 / 1119.61 2 2
4 13 934.72 35 12.85 1670 751 2.71 / 1120.36 2 2
5 13 192.84 35 13.81 617 298 3.01 / 1120.66 2 3
6 8 0.16 175 14.03 332 815 3.82 / 1121.48 2 13
Average= 4.96 (KJ/cycle)

Cycle 224 GMT 2/ 3/2021 4:37: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 30 13.98 484 203 0.20 / 1113.96 2 2
2 12 1127.72 80 9.46 1881 1424 1.63 / 1115.38 2 2
3 7 1131.80 23 10.84 1938 483 2.11 / 1115.87 2 2
4 13 921.48 35 12.96 1651 749 2.86 / 1116.62 2 2
5 13 82.64 35 13.97 463 226 3.08 / 1116.84 2 3
6 8 0.12 175 14.06 329 810 3.89 / 1117.65 2 16
Average= 4.97 (KJ/cycle)

Cycle 223 GMT 20/ 2/2021 10:31: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 30 13.96 475 199 0.20 / 1108.46 2 2
2 3 970.04 -1 13.96 475 0 0.00 / 1108.46 2 2
3 3 1030.80 1 12.32 1782 22 0.22 / 1108.48 2 2
4 12 1127.12 9 12.05 1943 211 0.43 / 1108.69 2 2
5 12 2003.40 80 9.79 3108 2434 2.87 / 1111.12 2 2
6 7 1994.76 23 10.37 3110 742 3.61 / 1111.87 2 2
7 13 1017.24 35 12.98 1792 814 4.42 / 1112.68 2 2
8 13 137.04 35 13.94 544 265 4.69 / 1112.95 2 3
9 8 -0.04 175 14.11 329 812 5.50 / 1113.76 2 16
Average= 4.97 (KJ/cycle)

Cycle 222 GMT 19/ 2/2021 7: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 30 13.92 491 205 0.21 / 1104.68 2 2
2 12 1126.24 80 8.15 1825 1190 1.39 / 1105.87 2 2
3 7 1133.28 23 10.65 1934 474 1.87 / 1106.35 2 2
4 13 959.24 35 12.79 1707 764 2.63 / 1107.11 2 2
5 13 262.04 35 13.73 714 343 2.98 / 1107.46 2 2
6 8 0.20 175 14.04 327 803 3.78 / 1108.26 2 14
Average= 4.97 (KJ/cycle)

Cycle 221 GMT 9/ 2/2021 12:44: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 30 13.96 498 209 0.21 / 1100.91 2 2
2 12 1118.08 80 8.89 1836 1306 1.51 / 1102.21 2 2
3 7 1123.60 23 10.76 1917 474 1.99 / 1102.69 2 2
4 13 933.32 35 12.88 1665 751 2.74 / 1103.44 2 2
5 13 111.92 35 13.93 498 243 2.98 / 1103.68 2 3
6 8 0.12 175 14.06 325 800 3.78 / 1104.48 2 14
Average= 4.98 (KJ/cycle)

Cycle 220 GMT 30/ 1/2021 18:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 30 13.99 501 210 0.21 / 1097.11 2 2
2 12 1138.00 80 9.64 1873 1444 1.65 / 1098.55 2 2
3 7 1141.80 23 10.88 1951 488 2.14 / 1099.04 2 2
4 13 724.76 35 13.24 1379 639 2.78 / 1099.68 2 2
5 13 52.36 35 14.04 415 204 2.99 / 1099.88 2 3
6 8 0.28 175 14.08 330 813 3.80 / 1100.70 2 19
Average= 4.98 (KJ/cycle)

Cycle 219 GMT 21/ 1/2021 0:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 30 13.94 485 203 0.20 / 1091.60 2 2
2 12 1110.84 9 12.14 1910 209 0.41 / 1091.81 2 2
3 12 2002.40 80 9.90 3101 2456 2.87 / 1094.27 2 2
4 7 1994.08 23 10.42 3114 746 3.61 / 1095.01 2 2
5 13 1012.88 35 13.01 1783 812 4.43 / 1095.83 2 2
6 13 129.56 35 13.94 532 260 4.69 / 1096.09 2 3
7 8 0.12 175 14.11 329 812 5.50 / 1096.90 2 13
Average= 4.99 (KJ/cycle)

Cycle 218 GMT 19/ 1/2021 20:55: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 30 13.93 489 204 0.20 / 1087.77 2 2
2 12 1140.36 80 8.20 1858 1219 1.42 / 1088.99 2 2
3 7 1147.56 23 10.71 1967 485 1.91 / 1089.47 2 2
4 13 971.32 35 12.85 1719 773 2.68 / 1090.25 2 2
5 13 262.32 35 13.73 716 344 3.02 / 1090.59 2 3
6 8 0.40 175 14.04 330 811 3.84 / 1091.40 2 13
Average= 4.98 (KJ/cycle)

Cycle 217 GMT 10/ 1/2021 2:38: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 30 13.95 490 205 0.21 / 1083.96 2 2
2 12 1130.96 80 9.03 1848 1335 1.54 / 1085.30 2 2
3 7 1136.72 23 10.82 1932 481 2.02 / 1085.78 2 2
4 13 933.64 35 12.93 1664 753 2.77 / 1086.53 2 2
5 13 95.84 35 13.97 466 228 3.00 / 1086.76 2 3
6 8 0.12 175 14.05 328 806 3.81 / 1087.57 2 12
Average= 4.99 (KJ/cycle)

Cycle 216 GMT 31/12/2020 8:24: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 29 13.94 498 201 0.20 / 1080.04 2 2
2 12 1127.08 80 9.70 1857 1441 1.64 / 1081.48 2 2
3 7 1129.92 23 10.95 1930 486 2.13 / 1081.97 2 2
4 13 913.84 35 13.04 1641 749 2.88 / 1082.72 2 2
5 13 84.32 35 13.99 465 228 3.11 / 1082.95 2 3
6 8 0.00 175 14.08 329 811 3.92 / 1083.76 2 17
Average= 4.99 (KJ/cycle)

Cycle 215 GMT 21/12/2020 14:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 29 13.93 500 202 0.20 / 1074.51 2 2
2 3 1016.24 1 12.34 1772 22 0.22 / 1074.54 2 2
3 12 1131.44 9 12.17 1953 214 0.44 / 1074.75 2 2
4 12 2002.20 80 10.04 3120 2506 2.94 / 1077.26 2 2
5 7 1993.16 23 10.46 3110 748 3.69 / 1078.00 2 2
6 13 993.96 35 13.05 1729 790 4.48 / 1078.79 2 2
7 13 110.96 35 13.99 497 243 4.73 / 1079.04 2 3
8 8 0.16 175 14.11 326 805 5.53 / 1079.84 2 14
Average= 5.00 (KJ/cycle)

Cycle 214 GMT 20/12/2020 11: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 30 13.92 489 204 0.20 / 1070.73 2 2
2 12 1118.96 80 8.50 1810 1231 1.44 / 1071.96 2 2
3 7 1124.68 23 10.81 1905 474 1.91 / 1072.44 2 2
4 13 939.68 35 12.87 1683 758 2.67 / 1073.19 2 2
5 13 216.48 35 13.80 648 313 2.98 / 1073.51 2 3
6 8 0.16 175 14.05 327 804 3.78 / 1074.31 2 12
Average= 5.00 (KJ/cycle)

Cycle 213 GMT 10/12/2020 16:51: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 29 13.91 506 204 0.20 / 1066.88 2 2
2 12 1124.88 80 9.11 1858 1354 1.56 / 1068.23 2 2
3 7 1129.72 23 10.89 1934 484 2.04 / 1068.72 2 2
4 13 933.68 35 12.96 1675 760 2.80 / 1069.48 2 2
5 13 84.88 35 13.97 470 230 3.03 / 1069.71 2 3
6 8 0.08 175 14.05 333 819 3.85 / 1070.53 2 14
Average= 5.00 (KJ/cycle)

Cycle 212 GMT 30/11/2020 22:43:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 29 13.96 483 196 0.20 / 1063.08 2 2
2 12 1132.80 80 9.75 1869 1458 1.65 / 1064.54 2 2
3 7 1135.92 23 10.96 1942 490 2.14 / 1065.03 2 2
4 13 717.60 35 13.27 1372 637 2.78 / 1065.66 2 2
5 13 42.80 35 14.06 405 199 2.98 / 1065.86 2 3
6 8 0.24 175 14.07 331 815 3.79 / 1066.68 2 15
Average= 5.01 (KJ/cycle)

Cycle 211 GMT 21/11/2020 4:30:58

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 29 13.96 477 193 0.19 / 1057.58 2 2
2 12 1120.72 9 12.26 1909 211 0.40 / 1057.79 2 2
3 12 2002.16 80 10.00 3113 2490 2.89 / 1060.28 2 2
4 7 1993.52 23 10.47 3109 749 3.64 / 1061.03 2 2
5 13 991.44 35 13.06 1745 798 4.44 / 1061.83 2 2
6 13 109.16 35 14.00 502 246 4.69 / 1062.07 2 3
7 8 0.04 175 14.11 328 810 5.50 / 1062.88 2 12
Average= 5.01 (KJ/cycle)

Cycle 210 GMT 20/11/2020 1: 3:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 30 13.93 494 206 0.21 / 1053.88 2 2
2 12 1111.60 80 8.74 1804 1261 1.47 / 1055.15 2 2
3 7 1117.68 23 10.87 1903 476 1.94 / 1055.62 2 2
4 13 920.96 35 12.96 1633 741 2.68 / 1056.36 2 2
5 13 102.60 35 13.95 484 236 2.92 / 1056.60 2 3
6 8 0.00 175 14.06 320 787 3.71 / 1057.39 2 16
Average= 5.01 (KJ/cycle)

Cycle 209 GMT 10/11/2020 6:55: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 29 13.92 505 204 0.20 / 1050.05 2 2
2 12 1123.52 80 9.32 1837 1370 1.57 / 1051.42 2 2
3 7 1127.20 23 10.96 1915 483 2.06 / 1051.90 2 2
4 13 918.52 35 13.03 1638 747 2.80 / 1052.65 2 2
5 13 75.52 35 14.00 445 218 3.02 / 1052.87 2 3
6 8 0.04 175 14.06 329 810 3.83 / 1053.68 2 14
Average= 5.02 (KJ/cycle)

Cycle 208 GMT 31/10/2020 12:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 29 13.92 491 198 0.20 / 1046.45 2 2
2 12 1118.00 80 9.88 1855 1466 1.66 / 1047.92 2 2
3 7 1120.88 23 11.05 1923 489 2.15 / 1048.40 2 2
4 13 696.48 35 13.33 1340 625 2.78 / 1049.03 2 3
5 8 0.20 175 14.07 332 817 3.60 / 1049.85 2 9
Average= 5.02 (KJ/cycle)

Cycle 207 GMT 21/10/2020 18:36: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 29 13.92 496 200 0.20 / 1040.91 2 2
2 12 1117.72 9 12.32 1909 212 0.41 / 1041.13 2 2
3 12 2002.00 80 10.19 3119 2543 2.95 / 1043.67 2 2
4 7 1993.00 23 10.52 3121 755 3.71 / 1044.42 2 2
5 13 971.44 35 13.09 1703 780 4.49 / 1045.20 2 2
6 13 96.96 35 14.01 476 233 4.72 / 1045.44 2 3
7 8 0.00 175 14.09 330 814 5.54 / 1046.25 2 13
Average= 5.03 (KJ/cycle)

Cycle 206 GMT 20/10/2020 14:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 30 13.91 498 208 0.21 / 1037.15 2 2
2 12 1114.72 80 8.88 1814 1289 1.50 / 1038.44 2 2
3 7 1120.56 23 10.95 1906 480 1.98 / 1038.92 2 2
4 13 930.56 35 12.99 1667 758 2.73 / 1039.68 2 2
5 13 92.32 35 13.96 476 233 2.97 / 1039.91 2 3
6 8 0.12 175 14.05 328 806 3.77 / 1040.71 2 15
Average= 5.03 (KJ/cycle)

Cycle 205 GMT 10/10/2020 20:42: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 29 13.93 503 203 0.20 / 1033.28 2 2
2 12 1114.88 80 9.52 1844 1404 1.61 / 1034.69 2 2
3 7 1119.28 23 11.04 1895 481 2.09 / 1035.17 2 2
4 13 905.52 35 13.08 1637 749 2.84 / 1035.92 2 2
5 13 40.16 35 14.05 401 197 3.04 / 1036.12 2 3
6 8 0.00 175 14.05 335 824 3.86 / 1036.94 2 12
Average= 5.03 (KJ/cycle)

Cycle 204 GMT 1/10/2020 2:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 29 13.92 504 203 0.20 / 1029.49 2 2
2 12 1120.64 50 10.04 1866 937 1.14 / 1030.43 2 2
3 7 1126.44 23 11.46 1918 506 1.65 / 1030.94 2 2
4 13 985.72 35 13.03 1738 793 2.44 / 1031.73 2 2
5 13 303.64 35 13.73 773 371 2.81 / 1032.10 2 2
6 13 4.80 35 14.12 348 172 2.98 / 1032.27 2 4
7 8 0.28 175 14.06 329 810 3.79 / 1033.08 2 19
Average= 5.04 (KJ/cycle)

Cycle 203 GMT 21/ 9/2020 8:16: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 29 13.93 514 208 0.21 / 1024.42 2 2
2 12 1122.60 9 12.40 1966 219 0.43 / 1024.64 2 2
3 12 2001.96 50 10.77 3120 1680 2.11 / 1026.32 2 2
4 7 1996.96 23 10.57 3130 761 2.87 / 1027.08 2 2
5 13 1317.76 35 12.76 2202 983 3.85 / 1028.06 2 2
6 13 356.76 35 13.71 844 405 4.26 / 1028.47 2 2
7 8 -0.08 175 14.08 333 821 5.08 / 1029.29 2 15
Average= 5.05 (KJ/cycle)

Cycle 202 GMT 20/ 9/2020 4:33: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 29 13.91 504 203 0.20 / 1020.70 2 2
2 12 1127.16 50 8.50 1823 775 0.98 / 1021.48 2 2
3 7 1133.32 23 11.29 1954 507 1.49 / 1021.99 2 2
4 13 1029.04 35 12.90 1807 816 2.30 / 1022.80 2 2
5 13 597.48 35 13.38 1209 566 2.87 / 1023.37 2 2
6 8 0.52 175 14.03 344 845 3.71 / 1024.21 2 10
Average= 5.05 (KJ/cycle)

Cycle 201 GMT 10/ 9/2020 10: 7:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 29 13.95 499 202 0.20 / 1017.02 2 2
2 12 1101.28 50 9.36 1817 850 1.05 / 1017.87 2 2
3 7 1107.40 23 11.37 1903 498 1.55 / 1018.37 2 2
4 13 979.96 35 12.94 1734 785 2.34 / 1019.15 2 2
5 13 522.36 35 13.48 1093 516 2.85 / 1019.67 2 2
6 8 -0.28 175 14.03 340 835 3.69 / 1020.50 2 12
Average= 5.05 (KJ/cycle)

Cycle 200 GMT 31/ 8/2020 15:53: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 30 13.92 500 209 0.21 / 1013.22 2 2
2 3 970.80 -1 13.92 500 0 0.00 / 1013.22 2 2
3 3 1032.76 1 12.98 1801 23 0.23 / 1013.24 2 2
4 12 1128.20 50 10.03 1875 940 1.17 / 1014.18 2 2
5 7 1133.36 23 11.43 1943 511 1.68 / 1014.69 2 2
6 13 984.28 40 12.97 1734 900 2.58 / 1015.59 2 2
7 13 261.72 40 13.76 718 395 2.98 / 1015.99 2 3
8 8 0.32 175 14.05 336 826 3.80 / 1016.82 2 13
Average= 5.06 (KJ/cycle)

Cycle 199 GMT 21/ 8/2020 21:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 29 13.93 494 200 0.20 / 1007.98 2 2
2 12 1115.60 9 12.39 1932 215 0.41 / 1008.19 2 2
3 12 2002.28 50 10.67 3132 1671 2.09 / 1009.86 2 2
4 7 1997.36 23 10.61 3142 767 2.85 / 1010.63 2 2
5 13 1317.68 40 12.68 2178 1105 3.96 / 1011.73 2 2
6 13 327.36 40 13.71 812 445 4.40 / 1012.18 2 3
7 8 -0.12 175 14.06 338 832 5.23 / 1013.01 2 10
Average= 5.07 (KJ/cycle)

Cycle 198 GMT 20/ 8/2020 17:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 29 13.90 516 208 0.21 / 1004.28 2 2
2 12 1131.44 50 8.43 1839 775 0.98 / 1005.06 2 2
3 7 1137.76 23 11.23 1942 502 1.48 / 1005.56 2 2
4 13 1040.36 40 12.78 1813 927 2.41 / 1006.49 2 2
5 13 372.20 40 13.60 875 476 2.89 / 1006.96 2 3
6 8 0.12 175 14.04 331 813 3.70 / 1007.78 2 15
Average= 5.06 (KJ/cycle)

Cycle 197 GMT 10/ 8/2020 23:23: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 28 13.96 489 191 0.19 / 1000.50 2 2
2 3 1040.16 2 12.87 1825 47 0.24 / 1000.54 2 2
3 12 1130.60 50 9.31 1859 865 1.10 / 1001.41 2 2
4 7 1136.92 23 11.29 1951 507 1.61 / 1001.92 2 2
5 13 1007.68 40 12.85 1767 908 2.52 / 1002.82 2 2
6 13 318.76 40 13.67 798 436 2.95 / 1003.26 2 3
7 8 0.52 175 14.05 332 816 3.77 / 1004.08 2 16
Average= 5.07 (KJ/cycle)

Cycle 196 GMT 1/ 8/2020 4:56: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 29 13.98 491 199 0.20 / 996.77 2 2
2 3 963.84 -1 13.98 491 0 0.00 / 996.77 2 2
3 3 1017.92 1 12.73 1789 23 0.22 / 996.79 2 2
4 12 1142.76 50 9.88 1893 935 1.16 / 997.73 2 2
5 7 1148.60 23 11.38 1969 515 1.67 / 998.24 2 2
6 13 1002.44 40 12.91 1775 917 2.59 / 999.16 2 2
7 13 154.04 40 13.88 572 318 2.91 / 999.48 2 3
8 8 -0.40 175 14.06 337 829 3.74 / 1000.31 2 14
Average= 5.08 (KJ/cycle)

Cycle 195 GMT 22/ 7/2020 10:32: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 29 13.93 491 198 0.20 / 991.28 2 2
2 12 1110.40 9 12.32 1942 215 0.41 / 991.50 2 2
3 12 2002.76 50 10.65 3136 1670 2.08 / 993.17 2 2
4 7 1997.96 23 10.62 3104 758 2.84 / 993.92 2 2
5 13 1520.24 40 12.44 2490 1239 4.08 / 995.16 2 2
6 13 496.92 40 13.52 1057 572 4.65 / 995.73 2 3
7 8 0.12 175 14.08 339 835 5.49 / 996.57 2 14
Average= 5.08 (KJ/cycle)

Cycle 194 GMT 21/ 7/2020 7: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 29 13.95 491 199 0.20 / 987.48 2 2
2 12 1125.80 50 8.36 1822 762 0.96 / 988.25 2 2
3 7 1132.32 23 11.16 1927 495 1.45 / 988.74 2 2
4 13 1021.76 40 12.72 1796 914 2.37 / 989.65 2 2
5 13 566.00 40 13.37 1148 614 2.98 / 990.27 2 2
6 8 0.32 175 14.05 331 814 3.80 / 991.08 2 15
Average= 5.08 (KJ/cycle)

Cycle 193 GMT 11/ 7/2020 12:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 29 13.96 493 200 0.20 / 983.81 2 2
2 12 1114.52 50 9.08 1839 835 1.03 / 984.64 2 2
3 7 1120.48 23 11.29 1918 498 1.53 / 985.14 2 2
4 13 984.76 40 12.81 1745 894 2.43 / 986.03 2 2
5 13 320.12 40 13.66 803 439 2.87 / 986.47 2 3
6 8 0.08 175 14.05 331 814 3.68 / 987.29 2 14
Average= 5.09 (KJ/cycle)

Cycle 192 GMT 1/ 7/2020 18:29: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 29 14.00 495 201 0.20 / 980.03 2 2
2 12 1132.24 50 9.92 1881 933 1.13 / 980.96 2 2
3 7 1137.84 23 11.37 1954 511 1.64 / 981.47 2 2
4 13 988.48 40 12.90 1749 902 2.55 / 982.37 2 2
5 13 283.88 40 13.73 747 410 2.96 / 982.78 2 3
6 8 0.12 175 14.06 334 822 3.78 / 983.61 2 10
Average= 5.10 (KJ/cycle)

Cycle 191 GMT 22/ 6/2020 0:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 31 13.97 488 211 0.21 / 974.89 2 2
2 3 943.52 -1 13.97 488 0 0.00 / 974.89 2 2
3 12 1118.32 9 12.46 1932 217 0.43 / 975.10 2 2
4 12 2007.68 50 10.67 3144 1677 2.11 / 976.78 2 2
5 7 2003.36 23 10.63 3138 767 2.87 / 977.55 2 2
6 13 1332.64 40 12.66 2209 1119 3.99 / 978.67 2 2
7 13 195.08 40 13.86 621 344 4.34 / 979.01 2 3
8 8 0.12 175 14.10 331 817 5.15 / 979.83 2 12
Average= 5.10 (KJ/cycle)

Cycle 190 GMT 20/ 6/2020 19:59: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 26 13.99 480 175 0.17 / 970.72 2 2
2 3 1075.76 2 12.74 1879 48 0.22 / 970.77 2 2
3 3 1040.44 1 12.46 1820 23 0.25 / 970.79 2 2
4 12 1148.96 50 8.38 1865 781 1.03 / 971.57 2 2
5 7 1155.48 23 11.06 1968 501 1.53 / 972.07 2 2
6 13 1050.44 40 12.68 1830 928 2.46 / 973.00 2 2
7 13 596.32 40 13.34 1195 638 3.09 / 973.64 2 2
8 13 28.56 40 14.07 384 216 3.31 / 973.85 2 4
9 8 0.16 175 14.06 334 822 4.13 / 974.67 2 22
Average= 5.10 (KJ/cycle)

Cycle 189 GMT 11/ 6/2020 1:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 29 13.97 487 197 0.20 / 967.04 2 2
2 12 1127.12 50 8.67 1859 806 1.00 / 967.85 2 2
3 7 1134.60 23 11.11 1942 496 1.50 / 968.34 2 2
4 13 1028.24 40 12.66 1800 912 2.41 / 969.25 2 2
5 13 362.04 40 13.60 865 471 2.88 / 969.72 2 2
6 8 -0.24 175 14.06 333 819 3.70 / 970.54 2 12
Average= 5.11 (KJ/cycle)

Cycle 188 GMT 1/ 6/2020 7: 7: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 29 14.03 505 205 0.21 / 963.34 2 2
2 12 1119.44 50 9.76 1859 907 1.11 / 964.25 2 2
3 7 1125.56 23 11.22 1923 496 1.61 / 964.74 2 2
4 13 982.28 40 12.78 1737 888 2.50 / 965.63 2 2
5 13 268.76 40 13.71 730 400 2.90 / 966.03 2 3
6 8 0.08 175 14.07 329 810 3.71 / 966.84 2 10
Average= 5.12 (KJ/cycle)

Cycle 187 GMT 22/ 5/2020 12:51: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 24 14.07 492 166 0.17 / 957.48 2 2
2 10 1029.00 4 13.14 1827 96 0.26 / 957.58 2 2
3 3 1070.60 2 12.77 1842 47 0.31 / 957.62 2 2
4 3 1034.60 1 12.36 1800 22 0.33 / 957.64 2 2
5 12 1147.52 5 12.37 1981 123 0.45 / 957.77 2 2
6 12 2007.48 50 10.96 3153 1728 2.18 / 959.50 2 2
7 7 2004.32 23 10.75 3143 777 2.96 / 960.27 2 2
8 13 1528.60 40 12.50 2502 1251 4.21 / 961.52 2 2
9 13 519.72 40 13.54 1086 588 4.80 / 962.11 2 3
10 13 5.24 40 14.17 348 197 5.00 / 962.31 2 3
11 8 0.08 175 14.14 334 826 5.82 / 963.14 2 24
Average= 5.12 (KJ/cycle)

Cycle 186 GMT 21/ 5/2020 10:29: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 29 14.03 497 202 0.20 / 951.45 2 2
2 12 1126.32 17 9.54 1842 299 0.50 / 951.75 2 2
3 12 2003.24 92 6.69 3043 1873 2.37 / 953.62 2 2
4 7 1998.36 23 10.13 3128 729 3.10 / 954.35 2 2
5 13 1784.36 40 11.99 2863 1373 4.48 / 955.72 2 2
6 13 763.64 40 13.25 1434 760 5.24 / 956.48 2 2
7 8 0.44 175 14.12 337 833 6.07 / 957.31 2 13
Average= 5.12 (KJ/cycle)

Cycle 185 GMT 11/ 5/2020 9:51: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 29 14.05 485 198 0.20 / 945.21 2 2
2 12 1127.20 17 9.28 1862 294 0.49 / 945.50 2 2
3 12 2003.76 92 6.53 3040 1826 2.32 / 947.33 2 2
4 7 1998.28 23 10.17 3112 728 3.05 / 948.06 2 2
5 13 1780.00 40 12.03 2858 1375 4.42 / 949.43 2 2
6 13 792.88 40 13.22 1474 779 5.20 / 950.21 2 2
7 13 11.08 40 14.16 358 203 5.40 / 950.41 2 4
8 8 0.20 175 14.13 336 831 6.23 / 951.25 2 19
Average= 5.11 (KJ/cycle)

Cycle 184 GMT 1/ 5/2020 8:25: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 29 14.08 482 197 0.20 / 939.11 2 2
2 3 971.04 -1 14.08 482 0 0.00 / 939.11 2 2
3 3 1026.24 1 12.29 1787 22 0.22 / 939.14 2 2
4 12 1153.36 17 9.33 1898 301 0.52 / 939.44 2 2
5 12 2001.28 80 6.82 3038 1658 2.18 / 941.09 2 2
6 7 1996.52 23 10.19 3111 729 2.91 / 941.82 2 2
7 13 1774.80 40 12.05 2823 1361 4.27 / 943.18 2 2
8 13 792.76 40 13.23 1468 777 5.04 / 943.96 2 2
9 13 51.96 40 14.09 414 233 5.28 / 944.19 2 4
10 8 0.04 175 14.15 330 817 6.09 / 945.01 2 15
Average= 5.11 (KJ/cycle)

Cycle 183 GMT 21/ 4/2020 8:27: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 29 14.06 489 199 0.20 / 933.05 2 2
2 12 1103.92 17 9.31 1828 289 0.49 / 933.34 2 2
3 12 1992.36 80 6.74 3028 1633 2.12 / 934.98 2 2
4 7 1987.36 23 10.18 3112 729 2.85 / 935.70 2 2
5 13 1783.88 40 12.02 2863 1377 4.23 / 937.08 2 2
6 13 784.00 40 13.22 1471 778 5.00 / 937.86 2 2
7 13 50.56 40 14.09 416 234 5.24 / 938.09 2 4
8 8 0.20 175 14.14 333 824 6.06 / 938.92 2 20
Average= 5.10 (KJ/cycle)

Cycle 182 GMT 11/ 4/2020 7:18: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 29 14.10 484 198 0.20 / 927.03 2 2
2 12 1104.12 17 9.63 1824 299 0.50 / 927.33 2 2
3 12 1989.12 80 6.70 3033 1626 2.12 / 928.95 2 2
4 7 1982.92 23 10.16 3132 732 2.85 / 929.69 2 2
5 13 1760.84 40 12.08 2818 1362 4.22 / 931.05 2 2
6 13 769.44 40 13.25 1441 764 4.98 / 931.81 2 2
7 13 45.28 40 14.11 403 227 5.21 / 932.04 2 5
8 8 0.08 175 14.16 329 815 6.02 / 932.85 2 23
Average= 5.10 (KJ/cycle)

Cycle 181 GMT 1/ 4/2020 6: 3: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 29 14.07 488 199 0.20 / 921.03 2 2
2 12 1133.44 17 9.22 1869 293 0.49 / 921.32 2 2
3 12 2000.48 77 6.74 3032 1574 2.07 / 922.89 2 2
4 7 1996.68 23 10.15 3124 729 2.79 / 923.62 2 2
5 13 1775.88 40 12.05 2832 1365 4.16 / 924.99 2 2
6 13 817.40 40 13.21 1512 799 4.96 / 925.79 2 2
7 13 30.44 40 14.13 388 219 5.18 / 926.01 2 5
8 8 0.40 175 14.15 333 825 6.00 / 926.83 2 20
Average= 5.09 (KJ/cycle)

Cycle 180 GMT 22/ 3/2020 5:42: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 29 14.11 492 201 0.20 / 915.29 2 2
2 12 1123.76 17 9.45 1851 297 0.50 / 915.59 2 2
3 12 2001.48 77 6.97 3021 1621 2.12 / 917.21 2 2
4 7 1996.40 23 10.22 3108 731 2.85 / 917.94 2 2
5 13 1576.40 40 12.34 2553 1260 4.11 / 919.20 2 2
6 13 821.64 40 13.20 1512 798 4.91 / 920.00 2 2
7 8 0.08 175 14.14 335 829 5.74 / 920.83 2 17
Average= 5.09 (KJ/cycle)

Cycle 179 GMT 12/ 3/2020 5: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 29 14.06 497 203 0.20 / 909.25 2 2
2 12 1128.80 17 9.34 1874 298 0.50 / 909.54 2 2
3 12 2000.20 77 6.98 3036 1632 2.13 / 911.18 2 2
4 7 1995.72 23 10.25 3088 728 2.86 / 911.90 2 2
5 13 1773.60 40 12.08 2853 1379 4.24 / 913.28 2 2
6 13 794.00 40 13.22 1483 784 5.02 / 914.07 2 2
7 13 24.88 40 14.15 373 211 5.23 / 914.28 2 4
8 8 -0.12 175 14.16 328 813 6.05 / 915.09 2 23
Average= 5.08 (KJ/cycle)

Cycle 178 GMT 2/ 3/2020 4:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 29 14.11 489 200 0.20 / 903.40 2 2
2 12 1122.48 16 9.47 1854 281 0.48 / 903.68 2 2
3 12 2002.00 69 7.10 3014 1477 1.96 / 905.16 2 2
4 7 1998.92 23 10.32 3135 744 2.70 / 905.90 2 2
5 13 1579.60 40 12.36 2565 1268 3.97 / 907.17 2 2
6 13 843.72 40 13.18 1549 817 4.79 / 907.99 2 2
7 13 29.88 40 14.13 393 222 5.01 / 908.21 2 4
8 8 0.04 175 14.14 338 836 5.84 / 909.04 2 20
Average= 5.08 (KJ/cycle)

Cycle 177 GMT 21/ 2/2020 4:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 29 14.08 501 205 0.20 / 897.43 2 2
2 12 1126.88 16 9.53 1866 285 0.49 / 897.72 2 2
3 12 2002.52 69 7.14 3039 1497 1.99 / 899.22 2 2
4 7 1998.96 23 10.31 3133 743 2.73 / 899.96 2 2
5 13 1786.68 40 12.10 2859 1384 4.11 / 901.34 2 2
6 13 800.92 40 13.24 1492 790 4.90 / 902.13 2 3
7 13 48.92 40 14.11 417 235 5.14 / 902.37 2 4
8 8 0.24 175 14.14 336 831 5.97 / 903.20 2 20
Average= 5.07 (KJ/cycle)

Cycle 176 GMT 11/ 2/2020 4:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 29 14.04 492 200 0.20 / 891.42 2 2
2 12 1124.24 16 9.60 1850 284 0.48 / 891.70 2 2
3 12 2000.28 69 7.29 3014 1516 2.00 / 893.22 2 2
4 7 1996.28 23 10.31 3134 743 2.74 / 893.96 2 2
5 13 1779.84 40 12.12 2870 1391 4.14 / 895.35 2 2
6 13 792.84 40 13.23 1491 789 4.92 / 896.14 2 2
7 13 45.04 40 14.12 418 236 5.16 / 896.38 2 5
8 8 0.20 175 14.13 344 851 6.01 / 897.23 2 16
Average= 5.07 (KJ/cycle)

Cycle 175 GMT 1/ 2/2020 4:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 29 14.09 493 201 0.20 / 885.63 2 2
2 12 1117.92 14 9.65 1849 250 0.45 / 885.88 2 2
3 12 2002.72 63 7.35 3023 1400 1.85 / 887.28 2 2
4 7 2000.16 23 10.38 3096 739 2.59 / 888.01 2 2
5 13 1787.20 40 12.07 2870 1386 3.98 / 889.40 2 2
6 13 812.56 40 13.22 1501 794 4.77 / 890.19 2 2
7 13 29.84 40 14.16 378 214 4.98 / 890.41 2 5
8 8 -0.12 175 14.16 327 810 5.79 / 891.22 2 16
Average= 5.06 (KJ/cycle)

Cycle 174 GMT 22/ 1/2020 4:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 29 14.15 494 203 0.20 / 879.78 2 2
2 12 1124.08 14 9.53 1869 249 0.45 / 880.03 2 2
3 12 2005.20 63 7.45 3085 1448 1.90 / 881.47 2 2
4 7 2002.60 23 10.41 3122 748 2.65 / 882.22 2 2
5 13 1791.32 40 12.15 2850 1385 4.03 / 883.61 2 2
6 13 818.76 40 13.23 1502 795 4.83 / 884.40 2 2
7 13 27.80 40 14.15 377 213 5.04 / 884.61 2 4
8 8 0.04 175 14.16 327 810 5.85 / 885.42 2 20
Average= 5.06 (KJ/cycle)

Cycle 173 GMT 12/ 1/2020 4:21: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 29 14.09 489 200 0.20 / 874.06 2 2
2 12 1115.08 10 8.99 1845 166 0.37 / 874.23 2 2
3 12 2001.12 56 7.45 3049 1272 1.64 / 875.50 2 2
4 7 2000.64 23 10.38 3098 740 2.38 / 876.24 2 2
5 13 1815.12 40 12.08 2894 1398 3.78 / 877.64 2 2
6 13 879.88 40 13.15 1603 843 4.62 / 878.48 2 2
7 13 78.32 40 14.05 462 260 4.88 / 878.74 2 4
8 8 0.24 175 14.14 337 834 5.71 / 879.57 2 20
Average= 5.06 (KJ/cycle)

Cycle 172 GMT 2/ 1/2020 4:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 29 14.13 479 196 0.20 / 868.28 2 2
2 12 1128.44 10 9.05 1838 166 0.36 / 868.44 2 2
3 12 2003.88 56 7.52 3029 1276 1.64 / 869.72 2 2
4 7 2003.12 23 10.44 3081 740 2.38 / 870.46 2 2
5 13 1806.88 40 12.13 2872 1393 3.77 / 871.85 2 2
6 13 1060.08 40 13.00 1828 951 4.72 / 872.80 2 2
7 13 61.84 40 14.09 430 242 4.96 / 873.04 2 4
8 8 0.16 175 14.14 330 817 5.78 / 873.86 2 15
Average= 5.05 (KJ/cycle)

Cycle 171 GMT 23/12/2019 5:10: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 29 14.14 480 197 0.20 / 862.48 2 2
2 12 1114.20 10 9.10 1822 166 0.36 / 862.65 2 2
3 12 2001.08 56 7.74 3028 1312 1.68 / 863.96 2 2
4 7 1999.92 23 10.42 3130 750 2.43 / 864.71 2 2
5 13 1790.52 40 12.15 2854 1387 3.81 / 866.10 2 2
6 13 1031.36 40 13.02 1803 939 4.75 / 867.04 2 2
7 13 49.72 40 14.12 408 230 4.98 / 867.27 2 4
8 8 0.08 175 14.14 329 814 5.80 / 868.08 2 22
Average= 5.05 (KJ/cycle)

Cycle 170 GMT 13/12/2019 5:53: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 29 14.08 503 205 0.21 / 856.74 2 2
2 12 1108.16 10 9.35 1814 170 0.37 / 856.91 2 2
3 12 2006.20 56 7.73 3050 1320 1.70 / 858.23 2 2
4 7 2005.00 23 10.46 3131 753 2.45 / 858.98 2 2
5 13 1803.48 40 12.14 2890 1403 3.85 / 860.39 2 2
6 13 859.92 40 13.20 1554 821 4.67 / 861.21 2 2
7 13 69.84 40 14.08 444 250 4.92 / 861.46 2 4
8 8 0.00 175 14.14 334 826 5.75 / 862.28 2 17
Average= 5.04 (KJ/cycle)

Cycle 169 GMT 3/12/2019 6:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 29 14.08 503 205 0.21 / 850.82 2 2
2 12 1115.88 10 8.87 1849 164 0.37 / 850.99 2 2
3 12 2006.68 56 7.96 3041 1356 1.72 / 852.34 2 2
4 7 2005.28 23 10.47 3106 748 2.47 / 853.09 2 2
5 13 1799.44 40 12.15 2888 1404 3.88 / 854.49 2 2
6 13 1050.28 40 13.00 1838 956 4.83 / 855.45 2 2
7 13 55.52 40 14.10 429 242 5.07 / 855.69 2 4
8 8 0.36 175 14.12 341 843 5.92 / 856.53 2 17
Average= 5.04 (KJ/cycle)

Cycle 168 GMT 23/11/2019 6:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 29 14.08 501 205 0.20 / 845.03 2 2
2 12 1126.00 10 9.22 1861 172 0.38 / 845.20 2 2
3 12 2001.24 56 8.26 3018 1396 1.77 / 846.60 2 2
4 7 1999.40 23 10.48 3126 753 2.53 / 847.35 2 2
5 13 1790.80 40 12.18 2865 1396 3.92 / 848.75 2 2
6 13 824.72 40 13.23 1519 804 4.73 / 849.55 2 2
7 13 50.20 40 14.11 421 238 4.96 / 849.79 2 5
8 8 0.08 175 14.14 335 829 5.79 / 850.62 2 20
Average= 5.03 (KJ/cycle)

Cycle 167 GMT 13/11/2019 7:34:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 29 14.07 509 208 0.21 / 839.53 2 2
2 12 1131.08 10 9.31 1869 174 0.38 / 839.70 2 2
3 12 2000.84 56 8.35 3054 1428 1.81 / 841.13 2 2
4 7 1999.40 23 10.55 3108 754 2.56 / 841.88 2 2
5 13 1601.92 40 12.43 2583 1284 3.85 / 843.17 2 2
6 13 857.80 40 13.19 1571 829 4.68 / 844.00 2 2
7 8 0.20 175 14.12 336 830 5.51 / 844.83 2 18
Average= 5.03 (KJ/cycle)

Cycle 166 GMT 3/11/2019 8: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 29 14.10 501 205 0.20 / 833.91 2 2
2 12 1128.48 10 9.32 1852 173 0.38 / 834.08 2 2
3 12 2000.52 48 8.50 3039 1240 1.62 / 835.32 2 2
4 7 1999.48 23 10.59 3105 756 2.37 / 836.08 2 2
5 13 1793.60 40 12.16 2873 1397 3.77 / 837.48 2 2
6 13 844.80 40 13.20 1545 816 4.59 / 838.29 2 2
7 13 14.12 40 14.17 362 205 4.79 / 838.50 2 5
8 8 0.12 175 14.10 333 822 5.61 / 839.32 2 17
Average= 5.03 (KJ/cycle)

Cycle 165 GMT 24/10/2019 8:31: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 29 14.11 488 200 0.20 / 828.29 2 2
2 12 1122.28 10 9.21 1869 172 0.37 / 828.46 2 2
3 12 2001.92 48 8.71 3041 1271 1.64 / 829.74 2 2
4 7 2000.96 23 10.60 3090 753 2.40 / 830.49 2 2
5 13 1789.72 40 12.16 2870 1396 3.79 / 831.89 2 2
6 13 830.28 40 13.21 1520 803 4.60 / 832.69 2 2
7 13 14.16 40 14.16 357 202 4.80 / 832.89 2 4
8 8 -0.04 175 14.10 330 814 5.61 / 833.71 2 23
Average= 5.02 (KJ/cycle)

Cycle 164 GMT 14/10/2019 9: 6: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 29 14.12 494 202 0.20 / 822.63 2 2
2 12 1129.12 10 9.59 1864 179 0.38 / 822.81 2 2
3 12 2001.36 48 8.97 3030 1305 1.69 / 824.12 2 2
4 7 2000.04 23 10.55 3148 764 2.45 / 824.88 2 2
5 13 1782.56 40 12.17 2855 1390 3.84 / 826.27 2 2
6 13 806.44 40 13.23 1496 792 4.63 / 827.06 2 2
7 13 26.00 40 14.15 378 214 4.84 / 827.28 2 5
8 8 0.12 175 14.12 331 818 5.66 / 828.09 2 17
Average= 5.02 (KJ/cycle)

Cycle 163 GMT 4/10/2019 9:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 28 14.11 499 197 0.20 / 817.14 2 2
2 12 1120.80 10 9.86 1860 183 0.38 / 817.32 2 2
3 12 2000.72 48 9.20 3059 1351 1.73 / 818.68 2 2
4 7 1999.56 23 10.60 3154 769 2.50 / 819.44 2 2
5 13 1781.28 40 12.21 2852 1393 3.89 / 820.84 2 2
6 13 794.64 40 13.27 1464 777 4.67 / 821.61 2 2
7 8 0.08 175 14.13 330 816 5.49 / 822.43 2 12
Average= 5.01 (KJ/cycle)

Cycle 162 GMT 24/ 9/2019 10: 7:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 28 14.12 494 195 0.20 / 811.64 2 2
2 12 1126.32 7 8.84 1835 114 0.31 / 811.76 2 2
3 12 2007.12 40 8.92 3048 1088 1.40 / 812.84 2 2
4 7 2007.00 23 10.70 3119 768 2.16 / 813.61 2 2
5 13 1818.40 40 12.13 2905 1410 3.57 / 815.02 2 2
6 13 891.12 40 13.17 1610 848 4.42 / 815.87 2 2
7 13 76.68 40 14.09 450 254 4.68 / 816.12 2 4
8 8 0.28 175 14.11 333 822 5.50 / 816.94 2 17
Average= 5.01 (KJ/cycle)

Cycle 161 GMT 14/ 9/2019 10:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 29 14.10 493 202 0.20 / 805.93 2 2
2 3 971.28 -1 14.10 493 0 0.00 / 805.93 2 2
3 3 1028.64 1 12.79 1807 23 0.22 / 805.95 2 2
4 12 1145.40 7 9.79 1876 129 0.35 / 806.08 2 2
5 12 2002.24 40 9.41 3044 1146 1.50 / 807.22 2 2
6 7 2002.36 23 10.74 3129 773 2.27 / 808.00 2 2
7 13 1806.48 40 12.19 2879 1404 3.68 / 809.40 2 2
8 13 1083.20 40 12.97 1891 981 4.66 / 810.38 2 2
9 13 61.04 40 14.10 431 243 4.90 / 810.62 2 4
10 8 -0.04 175 14.12 333 823 5.72 / 811.45 2 17
Average= 5.01 (KJ/cycle)

Cycle 160 GMT 4/ 9/2019 11:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 29 14.10 489 200 0.20 / 800.42 2 2
2 12 1098.48 7 9.41 1830 121 0.32 / 800.54 2 2
3 12 2002.36 40 9.14 3040 1111 1.43 / 801.65 2 2
4 7 2002.00 23 10.71 3134 772 2.20 / 802.42 2 2
5 13 1809.68 40 12.17 2891 1407 3.61 / 803.83 2 2
6 13 883.48 40 13.19 1580 834 4.44 / 804.66 2 2
7 13 71.72 40 14.09 439 247 4.69 / 804.91 2 4
8 8 0.24 175 14.12 330 815 5.51 / 805.72 2 19
Average= 5.00 (KJ/cycle)

Cycle 159 GMT 25/ 8/2019 11:54: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 29 14.17 490 201 0.20 / 794.93 2 2
2 12 1122.28 7 9.37 1859 122 0.32 / 795.06 2 2
3 12 2006.44 40 9.35 3038 1136 1.46 / 796.19 2 2
4 7 2005.20 23 10.71 3095 762 2.22 / 796.95 2 2
5 13 1789.36 40 12.18 2855 1391 3.61 / 798.35 2 2
6 13 821.08 40 13.21 1523 805 4.42 / 799.15 2 2
7 13 65.52 40 14.10 434 245 4.66 / 799.40 2 5
8 8 0.04 175 14.13 332 821 5.48 / 800.22 2 19
Average= 5.00 (KJ/cycle)

Cycle 158 GMT 15/ 8/2019 12:23: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 29 14.10 507 207 0.21 / 789.47 2 2
2 12 1104.72 7 9.68 1832 124 0.33 / 789.60 2 2
3 12 2005.08 40 9.47 3033 1149 1.48 / 790.75 2 2
4 7 2005.20 23 10.74 3097 765 2.25 / 791.51 2 2
5 13 1805.12 40 12.18 2862 1394 3.64 / 792.91 2 2
6 13 857.44 40 13.18 1565 825 4.46 / 793.73 2 2
7 13 2.32 40 14.22 339 193 4.66 / 793.92 2 6
8 8 0.08 175 14.12 327 808 5.47 / 794.73 2 19
Average= 5.00 (KJ/cycle)

Cycle 157 GMT 5/ 8/2019 12:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 29 14.14 489 201 0.20 / 783.95 2 2
2 12 1123.12 7 10.11 1886 133 0.33 / 784.08 2 2
3 12 2000.48 40 9.57 3060 1171 1.51 / 785.25 2 2
4 7 1999.12 23 10.78 3104 770 2.27 / 786.02 2 2
5 13 1777.28 40 12.20 2848 1390 3.66 / 787.41 2 2
6 13 824.96 40 13.22 1517 802 4.47 / 788.21 2 2
7 13 60.32 40 14.11 429 242 4.71 / 788.46 2 5
8 8 -0.08 175 14.14 328 812 5.52 / 789.27 2 23
Average= 5.00 (KJ/cycle)

Cycle 156 GMT 26/ 7/2019 13:30: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 29 14.12 497 204 0.20 / 778.64 2 2
2 12 1108.48 7 10.55 1878 139 0.34 / 778.78 2 2
3 12 2001.44 40 9.73 3024 1177 1.52 / 779.96 2 2
4 7 2000.64 23 10.77 3119 773 2.29 / 780.73 2 2
5 13 1798.88 40 12.18 2885 1406 3.70 / 782.14 2 2
6 13 825.76 40 13.21 1522 804 4.50 / 782.94 2 3
7 8 0.24 175 14.13 326 806 5.31 / 783.75 2 13
Average= 4.99 (KJ/cycle)

Cycle 155 GMT 16/ 7/2019 13:52: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 29 14.16 501 206 0.21 / 773.08 2 2
2 12 1123.36 7 10.88 1893 144 0.35 / 773.22 2 2
3 12 2005.88 40 9.79 3072 1203 1.55 / 774.42 2 2
4 7 2004.24 23 10.75 3144 777 2.33 / 775.20 2 2
5 13 1781.88 40 12.18 2850 1389 3.72 / 776.59 2 2
6 13 814.96 40 13.21 1508 797 4.52 / 777.39 2 2
7 13 56.84 40 14.11 421 238 4.75 / 777.62 2 5
8 8 0.00 175 14.12 330 815 5.57 / 778.44 2 15
Average= 4.99 (KJ/cycle)

Cycle 154 GMT 6/ 7/2019 14:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 29 14.11 484 198 0.20 / 767.72 2 2
2 12 1113.32 7 11.16 1880 147 0.34 / 767.87 2 2
3 12 2001.64 40 9.90 3068 1215 1.56 / 769.09 2 2
4 7 2000.84 23 10.78 3099 768 2.33 / 769.85 2 2
5 13 1789.52 40 12.14 2873 1395 3.72 / 771.25 2 2
6 13 817.60 40 13.21 1517 802 4.52 / 772.05 2 3
7 8 0.40 175 14.11 332 820 5.34 / 772.87 2 15
Average= 4.99 (KJ/cycle)

Cycle 153 GMT 26/ 6/2019 14:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 29 14.13 485 199 0.20 / 762.16 2 2
2 12 1105.52 7 11.32 1875 149 0.35 / 762.30 2 2
3 12 2000.80 40 10.02 3046 1221 1.57 / 763.53 2 2
4 7 1999.76 23 10.74 3136 775 2.34 / 764.30 2 2
5 13 1786.80 40 12.17 2851 1388 3.73 / 765.69 2 2
6 13 804.60 40 13.21 1493 789 4.52 / 766.48 2 3
7 13 48.00 40 14.13 405 229 4.75 / 766.71 2 5
8 8 -0.24 175 14.10 332 819 5.57 / 767.53 2 21
Average= 4.98 (KJ/cycle)

Cycle 152 GMT 16/ 6/2019 15:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 29 14.12 486 199 0.20 / 756.62 2 2
2 12 1120.40 7 11.41 1890 151 0.35 / 756.77 2 2
3 12 2002.32 40 10.06 3109 1251 1.60 / 758.02 2 2
4 7 2000.32 23 10.77 3121 773 2.37 / 758.79 2 2
5 13 1782.80 40 12.14 2859 1388 3.76 / 760.18 2 2
6 13 795.44 40 13.23 1478 782 4.54 / 760.96 2 3
7 13 8.32 40 14.20 340 193 4.74 / 761.15 2 5
8 8 0.16 175 14.09 326 804 5.54 / 761.96 2 19
Average= 4.98 (KJ/cycle)

Cycle 151 GMT 6/ 6/2019 15:56: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 29 14.12 494 202 0.20 / 751.25 2 2
2 12 1116.60 7 11.46 1875 150 0.35 / 751.40 2 2
3 12 2002.80 40 10.23 3091 1265 1.62 / 752.67 2 2
4 7 2000.68 23 10.78 3122 774 2.39 / 753.44 2 2
5 13 1780.60 40 12.16 2855 1389 3.78 / 754.83 2 2
6 13 785.80 40 13.24 1460 773 4.55 / 755.60 2 3
7 8 0.20 175 14.12 329 813 5.37 / 756.42 2 15
Average= 4.98 (KJ/cycle)

Cycle 150 GMT 27/ 5/2019 16:16: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 29 14.20 478 197 0.20 / 746.10 2 2
2 12 1110.12 7 11.64 1867 152 0.35 / 746.25 2 2
3 12 2001.80 40 10.26 3096 1271 1.62 / 747.52 2 2
4 7 1999.84 23 10.77 3099 768 2.39 / 748.29 2 2
5 13 1587.64 40 12.37 2577 1275 3.66 / 749.56 2 2
6 13 639.76 40 13.39 1252 671 4.33 / 750.23 2 3
7 8 0.16 175 14.11 331 817 5.15 / 751.05 2 15
Average= 4.97 (KJ/cycle)

Cycle 149 GMT 17/ 5/2019 16:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 30 14.15 476 202 0.20 / 740.43 2 2
2 3 964.24 -1 14.15 476 0 0.00 / 740.43 2 2
3 3 1024.48 1 12.38 1804 22 0.22 / 740.45 2 2
4 12 1139.32 7 11.50 1930 155 0.38 / 740.61 2 2
5 12 2003.24 40 10.40 3096 1288 1.67 / 741.89 2 2
6 7 2000.88 23 10.81 3105 772 2.44 / 742.67 2 2
7 13 1793.12 40 12.11 2888 1399 3.84 / 744.07 2 2
8 13 795.96 40 13.21 1483 784 4.62 / 744.85 2 3
9 13 46.40 40 14.11 410 231 4.85 / 745.08 2 4
10 8 -0.08 175 14.10 332 819 5.67 / 745.90 2 19
Average= 4.97 (KJ/cycle)

Cycle 148 GMT 7/ 5/2019 16:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 30 14.14 479 203 0.20 / 735.05 2 2
2 12 1118.80 7 11.74 1891 155 0.36 / 735.21 2 2
3 12 2002.48 40 10.39 3095 1286 1.64 / 736.50 2 2
4 7 2000.64 23 10.80 3104 771 2.42 / 737.27 2 2
5 13 1575.96 40 12.40 2542 1261 3.68 / 738.53 2 2
6 13 622.84 40 13.41 1214 651 4.33 / 739.18 2 3
7 13 61.68 40 14.11 424 239 4.57 / 739.42 2 5
8 8 0.12 175 14.12 327 808 5.38 / 740.23 2 23
Average= 4.97 (KJ/cycle)

Cycle 147 GMT 27/ 4/2019 16:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 29 14.15 484 199 0.20 / 729.90 2 2
2 12 1142.36 7 11.70 1918 157 0.36 / 730.05 2 2
3 12 2003.92 40 10.63 3106 1321 1.68 / 731.37 2 2
4 7 2002.04 23 10.81 3127 777 2.45 / 732.15 2 2
5 13 1569.24 40 12.40 2535 1257 3.71 / 733.41 2 2
6 13 620.24 40 13.40 1212 650 4.36 / 734.06 2 3
7 8 0.00 175 14.13 321 794 5.15 / 734.85 2 14
Average= 4.97 (KJ/cycle)

Cycle 146 GMT 17/ 4/2019 17: 2: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 29 14.17 480 197 0.20 / 724.76 2 2
2 12 1124.56 7 11.75 1929 159 0.36 / 724.92 2 2
3 12 2002.88 40 10.56 3097 1308 1.66 / 726.23 2 2
4 7 2000.72 23 10.83 3072 765 2.43 / 726.99 2 2
5 13 1580.92 40 12.38 2550 1263 3.69 / 728.26 2 2
6 13 604.68 40 13.43 1194 641 4.33 / 728.90 2 3
7 8 0.24 175 14.13 323 799 5.13 / 729.70 2 21
Average= 4.96 (KJ/cycle)

Cycle 145 GMT 7/ 4/2019 17: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 29 14.13 491 201 0.20 / 719.21 2 2
2 12 1120.88 7 11.78 1912 158 0.36 / 719.37 2 2
3 12 2001.40 40 10.64 3070 1307 1.67 / 720.67 2 2
4 7 1999.24 23 10.84 3080 768 2.43 / 721.44 2 2
5 13 1781.80 40 12.14 2847 1383 3.82 / 722.82 2 2
6 13 759.60 40 13.26 1417 752 4.57 / 723.58 2 3
7 13 5.52 40 14.21 333 189 4.76 / 723.77 2 5
8 8 0.04 175 14.09 324 799 5.56 / 724.56 2 19
Average= 4.96 (KJ/cycle)

Cycle 144 GMT 28/ 3/2019 17:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 29 14.14 482 198 0.20 / 713.60 2 2
2 12 1123.24 7 11.71 1891 155 0.35 / 713.76 2 2
3 12 2003.20 40 10.66 3102 1323 1.68 / 715.08 2 2
4 7 2001.20 23 10.81 3125 777 2.45 / 715.86 2 2
5 13 1785.60 40 12.14 2863 1390 3.84 / 717.25 2 2
6 13 777.84 40 13.24 1454 770 4.61 / 718.02 2 3
7 13 9.56 40 14.20 342 194 4.81 / 718.21 2 4
8 8 -0.04 175 14.09 324 799 5.61 / 719.01 2 18
Average= 4.96 (KJ/cycle)

Cycle 143 GMT 18/ 3/2019 17:38: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 29 14.17 483 198 0.20 / 708.46 2 2
2 12 1120.00 7 11.79 1883 155 0.35 / 708.62 2 2
3 12 2002.80 40 10.78 3093 1334 1.69 / 709.95 2 2
4 7 2000.04 23 10.84 3113 776 2.46 / 710.73 2 2
5 13 1554.20 40 12.42 2512 1248 3.71 / 711.98 2 2
6 13 579.20 40 13.47 1141 615 4.33 / 712.59 2 3
7 8 0.08 175 14.11 329 812 5.14 / 713.40 2 15
Average= 4.95 (KJ/cycle)

Cycle 142 GMT 8/ 3/2019 17:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 29 14.13 492 202 0.20 / 703.20 2 2
2 12 1101.68 7 11.79 1870 154 0.36 / 703.35 2 2
3 12 2001.00 40 10.70 3096 1325 1.68 / 704.68 2 2
4 7 1999.08 23 10.82 3116 775 2.46 / 705.45 2 2
5 13 1777.24 40 12.13 2851 1383 3.84 / 706.84 2 2
6 13 563.12 40 13.46 1142 615 4.45 / 707.45 2 3
7 8 0.28 175 14.10 330 814 5.27 / 708.26 2 17
Average= 4.95 (KJ/cycle)

Cycle 141 GMT 26/ 2/2019 17:49: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 29 14.19 477 196 0.20 / 698.02 2 2
2 12 1113.20 7 11.78 1877 155 0.35 / 698.17 2 2
3 12 2002.16 40 10.76 3092 1331 1.68 / 699.50 2 2
4 7 1999.36 23 10.83 3135 781 2.46 / 700.28 2 2
5 13 1569.20 40 12.38 2545 1260 3.72 / 701.54 2 2
6 13 597.96 40 13.44 1180 634 4.36 / 702.18 2 3
7 8 0.32 175 14.11 331 817 5.17 / 703.00 2 16
Average= 4.95 (KJ/cycle)

Cycle 140 GMT 16/ 2/2019 17:44: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 29 14.13 486 199 0.20 / 692.65 2 2
2 12 1110.28 7 11.87 1869 155 0.35 / 692.81 2 2
3 12 2003.92 40 10.78 3106 1339 1.69 / 694.15 2 2
4 7 2001.36 23 10.83 3138 782 2.48 / 694.93 2 2
5 13 1558.44 40 12.42 2525 1254 3.73 / 696.18 2 2
6 13 589.40 40 13.44 1167 627 4.36 / 696.81 2 3
7 13 11.40 40 14.18 351 199 4.56 / 697.01 2 5
8 8 0.04 175 14.06 329 810 5.37 / 697.82 2 20
Average= 4.95 (KJ/cycle)

Cycle 139 GMT 6/ 2/2019 17:30: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 29 14.16 497 204 0.20 / 687.00 2 2
2 12 1137.88 7 11.77 1931 159 0.36 / 687.16 2 2
3 12 2007.20 40 10.85 3118 1353 1.72 / 688.51 2 2
4 7 2005.28 23 10.85 3140 784 2.50 / 689.30 2 2
5 13 1785.32 40 12.15 2845 1383 3.88 / 690.68 2 2
6 13 751.68 40 13.25 1422 754 4.64 / 691.43 2 3
7 13 18.52 40 14.16 365 207 4.84 / 691.64 2 5
8 8 0.16 175 14.05 331 814 5.66 / 692.45 2 24
Average= 4.95 (KJ/cycle)

Cycle 138 GMT 27/ 1/2019 17:47: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 29 14.18 489 201 0.20 / 681.81 2 2
2 12 1120.12 7 11.78 1898 157 0.36 / 681.97 2 2
3 12 2002.80 40 10.78 3123 1347 1.70 / 683.31 2 2
4 7 2000.20 23 10.85 3124 780 2.48 / 684.09 2 2
5 13 1562.36 40 12.41 2541 1261 3.75 / 685.36 2 2
6 13 587.16 40 13.44 1164 626 4.37 / 685.98 2 3
7 8 -0.04 175 14.10 331 817 5.19 / 686.80 2 16
Average= 4.94 (KJ/cycle)

Cycle 137 GMT 17/ 1/2019 17:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 29 14.11 495 203 0.20 / 676.61 2 2
2 12 1135.68 7 11.87 1916 159 0.36 / 676.77 2 2
3 12 2001.32 40 10.85 3108 1349 1.71 / 678.12 2 2
4 7 1999.08 23 10.86 3125 781 2.49 / 678.90 2 2
5 13 1552.40 40 12.43 2512 1249 3.74 / 680.15 2 2
6 13 586.20 40 13.45 1167 628 4.37 / 680.78 2 3
7 8 0.40 175 14.09 338 833 5.20 / 681.61 2 14
Average= 4.94 (KJ/cycle)

Cycle 136 GMT 7/ 1/2019 17:53: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 29 14.14 487 200 0.20 / 671.42 2 2
2 12 1118.88 7 11.79 1909 158 0.36 / 671.58 2 2
3 12 2002.84 40 10.87 3100 1348 1.71 / 672.93 2 2
4 7 2000.80 23 10.85 3114 777 2.48 / 673.70 2 2
5 13 1564.96 40 12.41 2546 1264 3.75 / 674.97 2 2
6 13 585.68 40 13.45 1155 621 4.37 / 675.59 2 3
7 8 0.24 175 14.10 332 819 5.19 / 676.41 2 12
Average= 4.94 (KJ/cycle)

Cycle 135 GMT 28/12/2018 17:58: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 29 14.15 489 201 0.20 / 666.02 2 2
2 12 1123.16 7 11.81 1908 158 0.36 / 666.17 2 2
3 12 2001.92 40 10.90 3106 1354 1.71 / 667.53 2 2
4 7 1998.80 23 10.89 3117 781 2.49 / 668.31 2 2
5 13 1560.52 40 12.43 2522 1254 3.75 / 669.56 2 2
6 13 591.88 40 13.46 1164 627 4.37 / 670.19 2 3
7 13 23.44 40 14.15 376 213 4.59 / 670.40 2 5
8 8 0.08 175 14.07 333 820 5.41 / 671.22 2 21
Average= 4.94 (KJ/cycle)

Cycle 134 GMT 18/12/2018 17:50: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 28 14.12 504 199 0.20 / 660.79 2 2
2 12 1122.20 7 11.74 1898 156 0.36 / 660.94 2 2
3 12 2000.72 40 10.86 3138 1363 1.72 / 662.31 2 2
4 7 1998.28 23 10.89 3119 781 2.50 / 663.09 2 2
5 13 1569.56 40 12.40 2543 1261 3.76 / 664.35 2 2
6 13 605.88 40 13.42 1196 642 4.40 / 664.99 2 3
7 8 0.12 175 14.09 334 824 5.23 / 665.82 2 12
Average= 4.93 (KJ/cycle)

Cycle 133 GMT 8/12/2018 17:44: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 28 14.11 498 197 0.20 / 655.58 2 2
2 12 1135.56 7 11.85 1903 158 0.35 / 655.73 2 2
3 12 2002.32 40 10.95 3088 1353 1.71 / 657.09 2 2
4 7 1999.20 23 10.87 3130 783 2.49 / 657.87 2 2
5 13 1552.40 40 12.40 2541 1260 3.75 / 659.13 2 2
6 13 579.24 40 13.46 1160 625 4.37 / 659.75 2 3
7 8 0.12 175 14.08 339 835 5.21 / 660.59 2 14
Average= 4.93 (KJ/cycle)

Cycle 132 GMT 28/11/2018 17:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 28 14.10 487 192 0.19 / 650.44 2 2
2 12 1107.60 7 11.77 1892 156 0.35 / 650.59 2 2
3 12 2002.32 40 10.94 3084 1350 1.70 / 651.94 2 2
4 7 1998.76 23 10.90 3104 778 2.48 / 652.72 2 2
5 13 1544.80 40 12.45 2493 1242 3.72 / 653.96 2 2
6 13 568.72 40 13.47 1128 608 4.33 / 654.57 2 3
7 8 0.12 175 14.09 328 809 5.13 / 655.38 2 12
Average= 4.93 (KJ/cycle)

Cycle 131 GMT 18/11/2018 17:45: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 28 14.09 493 194 0.19 / 645.26 2 2
2 12 1125.88 7 11.89 1882 157 0.35 / 645.41 2 2
3 12 2000.52 40 10.99 3101 1363 1.71 / 646.78 2 2
4 7 1997.36 23 10.90 3123 783 2.50 / 647.56 2 2
5 13 1562.36 40 12.42 2530 1257 3.75 / 648.82 2 2
6 13 576.96 40 13.47 1142 615 4.37 / 649.43 2 3
7 8 0.20 175 14.09 330 814 5.18 / 650.25 2 15
Average= 4.93 (KJ/cycle)

Cycle 130 GMT 8/11/2018 17:30: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 28 14.17 497 197 0.20 / 640.06 2 2
2 12 1120.56 7 11.88 1900 158 0.36 / 640.22 2 2
3 12 2000.84 40 10.94 3111 1361 1.72 / 641.58 2 2
4 7 1998.32 23 10.90 3107 779 2.50 / 642.36 2 2
5 13 1563.36 40 12.42 2542 1263 3.76 / 643.62 2 2
6 13 578.60 40 13.45 1152 620 4.38 / 644.24 2 3
7 8 0.08 175 14.09 333 821 5.20 / 645.06 2 16
Average= 4.92 (KJ/cycle)

Cycle 129 GMT 29/10/2018 17:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 28 14.12 508 201 0.20 / 634.83 2 2
2 12 1131.12 7 11.87 1893 157 0.36 / 634.99 2 2
3 12 2000.32 40 10.93 3120 1364 1.72 / 636.35 2 2
4 7 1997.60 23 10.85 3132 782 2.50 / 637.13 2 2
5 13 1561.00 40 12.41 2539 1260 3.76 / 638.39 2 2
6 13 597.96 40 13.45 1176 633 4.40 / 639.03 2 3
7 8 0.16 175 14.07 340 837 5.23 / 639.86 2 11
Average= 4.92 (KJ/cycle)

Cycle 128 GMT 19/10/2018 17:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 28 14.14 508 201 0.20 / 629.48 2 2
2 12 1127.80 6 11.86 1915 136 0.34 / 629.62 2 2
3 7 2003.60 62 10.61 3102 2041 2.38 / 631.66 2 2
4 13 1782.80 40 12.12 2836 1375 3.75 / 633.03 2 2
5 13 783.52 40 13.22 1465 775 4.53 / 633.81 2 3
6 8 -0.12 175 14.08 334 823 5.35 / 634.63 2 18
Average= 4.92 (KJ/cycle)

Cycle 127 GMT 9/10/2018 17:59: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 28 14.13 482 191 0.19 / 624.18 2 2
2 12 1107.92 6 11.93 1872 134 0.32 / 624.31 2 2
3 7 2001.32 61 10.56 3103 1999 2.32 / 626.31 2 2
4 13 1779.80 40 12.12 2829 1371 3.70 / 627.68 2 2
5 13 778.28 40 13.23 1455 770 4.47 / 628.45 2 3
6 8 0.32 175 14.08 336 828 5.29 / 629.28 2 12
Average= 4.92 (KJ/cycle)

Cycle 126 GMT 29/ 9/2018 18:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 28 14.11 507 200 0.20 / 618.86 2 2
2 12 1126.08 6 11.93 1893 136 0.34 / 618.99 2 2
3 7 2003.60 62 10.64 3105 2048 2.38 / 621.04 2 2
4 13 1589.52 40 12.35 2568 1269 3.65 / 622.31 2 2
5 13 619.16 40 13.42 1198 643 4.30 / 622.95 2 3
6 13 35.80 40 14.16 389 220 4.52 / 623.17 2 5
7 8 0.36 175 14.06 331 814 5.33 / 623.99 2 22
Average= 4.91 (KJ/cycle)

Cycle 125 GMT 19/ 9/2018 18:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 28 14.13 495 196 0.20 / 613.31 2 2
2 3 973.16 -1 14.13 495 0 0.00 / 613.31 2 2
3 3 1032.36 1 12.35 1790 22 0.22 / 613.33 2 2
4 12 1138.04 6 11.94 1894 136 0.35 / 613.46 2 2
5 7 2007.88 61 10.62 3118 2020 2.37 / 615.48 2 2
6 13 1787.32 40 12.11 2858 1384 3.76 / 616.87 2 2
7 13 803.04 40 13.21 1487 786 4.54 / 617.65 2 3
8 13 6.92 40 14.20 350 199 4.74 / 617.85 2 4
9 8 0.00 175 14.04 326 801 5.54 / 618.65 2 19
Average= 4.91 (KJ/cycle)

Cycle 124 GMT 9/ 9/2018 18:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 28 14.11 502 198 0.20 / 608.26 2 2
2 12 1113.80 6 11.91 1876 134 0.33 / 608.39 2 2
3 7 2001.04 61 10.64 3115 2022 2.35 / 610.41 2 2
4 13 1565.16 40 12.36 2535 1253 3.61 / 611.67 2 2
5 13 594.64 40 13.45 1172 631 4.24 / 612.30 2 3
6 8 -0.04 175 14.08 331 816 5.05 / 613.11 2 14
Average= 4.90 (KJ/cycle)

Cycle 123 GMT 30/ 8/2018 18:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 28 14.13 499 197 0.20 / 603.15 2 2
2 12 1115.44 6 11.90 1904 136 0.33 / 603.28 2 2
3 7 2002.80 62 10.71 3090 2052 2.39 / 605.33 2 2
4 13 1568.40 40 12.37 2540 1257 3.64 / 606.59 2 2
5 13 615.32 40 13.42 1204 646 4.29 / 607.24 2 3
6 8 0.24 175 14.09 333 821 5.11 / 608.06 2 13
Average= 4.90 (KJ/cycle)

Cycle 122 GMT 20/ 8/2018 18:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 28 14.11 508 201 0.20 / 597.76 2 2
2 12 1125.20 6 11.95 1911 137 0.34 / 597.90 2 2
3 7 2005.88 62 10.69 3106 2059 2.40 / 599.95 2 2
4 13 1790.96 40 12.11 2878 1394 3.79 / 601.35 2 2
5 13 779.96 40 13.24 1464 775 4.57 / 602.12 2 3
6 8 0.20 175 14.07 335 825 5.39 / 602.95 2 12
Average= 4.90 (KJ/cycle)

Cycle 121 GMT 10/ 8/2018 19:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 28 14.10 501 198 0.20 / 592.26 2 2
2 12 1115.60 6 11.96 1876 135 0.33 / 592.39 2 2
3 7 2003.00 61 10.68 3093 2015 2.35 / 594.41 2 2
4 13 1781.08 40 12.11 2842 1377 3.72 / 595.79 2 2
5 13 773.48 40 13.25 1441 764 4.49 / 596.55 2 3
6 13 17.00 40 14.18 363 206 4.69 / 596.76 2 6
7 8 -0.16 175 14.02 327 802 5.50 / 597.56 2 19
Average= 4.90 (KJ/cycle)

Cycle 120 GMT 31/ 7/2018 19:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 28 14.09 501 198 0.20 / 587.16 2 2
2 12 1109.44 6 12.02 1881 136 0.33 / 587.29 2 2
3 7 2000.96 61 10.70 3108 2029 2.36 / 589.32 2 2
4 13 1581.84 40 12.37 2549 1261 3.62 / 590.58 2 2
5 13 620.72 40 13.42 1214 652 4.27 / 591.23 2 3
6 8 0.12 175 14.08 336 828 5.10 / 592.06 2 11
Average= 4.89 (KJ/cycle)

Cycle 119 GMT 21/ 7/2018 19:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 28 14.17 481 191 0.19 / 581.91 2 2
2 12 1128.48 6 11.98 1912 137 0.33 / 582.05 2 2
3 7 2003.04 61 10.74 3087 2022 2.35 / 584.07 2 2
4 13 1566.52 40 12.34 2533 1250 3.60 / 585.32 2 2
5 13 809.44 40 13.21 1506 796 4.40 / 586.12 2 3
6 8 0.20 175 14.06 341 839 5.24 / 586.96 2 14
Average= 4.89 (KJ/cycle)

Cycle 118 GMT 11/ 7/2018 20: 0: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 28 14.13 490 194 0.19 / 576.87 2 2
2 12 1123.60 6 12.01 1900 137 0.33 / 577.00 2 2
3 7 2002.20 61 10.75 3092 2028 2.36 / 579.03 2 2
4 13 1566.28 40 12.39 2501 1239 3.60 / 580.27 2 2
5 13 605.32 40 13.43 1189 639 4.24 / 580.91 2 3
6 8 0.00 175 14.08 330 813 5.05 / 581.72 2 15
Average= 4.89 (KJ/cycle)

Cycle 117 GMT 1/ 7/2018 20: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 29 14.17 467 192 0.19 / 571.72 2 2
2 3 972.60 -1 14.17 467 0 0.00 / 571.72 2 2
3 3 1030.00 1 11.85 1826 22 0.21 / 571.74 2 2
4 12 1141.44 6 12.00 1938 140 0.35 / 571.88 2 2
5 7 2004.72 61 10.80 3109 2048 2.40 / 573.93 2 2
6 13 1582.80 40 12.34 2564 1266 3.67 / 575.20 2 2
7 13 628.64 40 13.41 1228 659 4.33 / 575.86 2 3
8 8 0.12 175 14.08 332 818 5.14 / 576.67 2 21
Average= 4.89 (KJ/cycle)

Cycle 116 GMT 21/ 6/2018 20: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 29 14.15 491 201 0.20 / 566.42 2 2
2 12 1106.64 6 12.06 1876 136 0.34 / 566.55 2 2
3 7 2002.40 62 10.79 3084 2063 2.40 / 568.62 2 2
4 13 1568.36 40 12.36 2542 1257 3.66 / 569.87 2 2
5 13 616.28 40 13.43 1200 645 4.30 / 570.52 2 3
6 13 7.80 40 14.20 351 199 4.50 / 570.72 2 5
7 8 0.08 175 14.02 331 812 5.31 / 571.53 2 18
Average= 4.88 (KJ/cycle)

Cycle 115 GMT 11/ 6/2018 20: 2: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 29 14.11 497 203 0.20 / 561.31 2 2
2 12 1100.32 6 12.15 1887 138 0.34 / 561.45 2 2
3 7 2000.52 61 10.77 3116 2047 2.39 / 563.50 2 2
4 13 1568.64 40 12.36 2551 1261 3.65 / 564.76 2 2
5 13 600.08 40 13.43 1189 639 4.29 / 565.40 2 3
6 8 0.04 175 14.08 332 818 5.11 / 566.22 2 12
Average= 4.88 (KJ/cycle)

Cycle 114 GMT 1/ 6/2018 20: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 29 14.16 491 202 0.20 / 556.21 2 2
2 12 1110.16 6 12.15 1886 137 0.34 / 556.35 2 2
3 7 2001.60 61 10.84 3103 2052 2.39 / 558.40 2 2
4 13 1565.40 40 12.37 2546 1260 3.65 / 559.66 2 2
5 13 597.08 40 13.44 1176 632 4.28 / 560.29 2 3
6 8 0.44 175 14.08 333 821 5.10 / 561.11 2 13
Average= 4.88 (KJ/cycle)

Cycle 113 GMT 22/ 5/2018 20: 8: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 29 14.17 482 198 0.20 / 550.93 2 2
2 12 1110.04 6 12.13 1904 139 0.34 / 551.07 2 2
3 7 2007.56 62 10.81 3131 2098 2.44 / 553.17 2 2
4 13 1788.76 40 12.11 2876 1393 3.83 / 554.56 2 2
5 13 583.16 40 13.47 1161 626 4.45 / 555.19 2 3
6 8 0.16 175 14.09 332 819 5.27 / 556.01 2 10
Average= 4.88 (KJ/cycle)

Cycle 112 GMT 12/ 5/2018 20:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 28 14.16 489 194 0.19 / 545.53 2 2
2 12 1133.76 6 12.19 1936 142 0.34 / 545.67 2 2
3 7 2005.76 62 10.87 3122 2104 2.44 / 547.78 2 2
4 13 1787.84 40 12.12 2872 1392 3.83 / 549.17 2 2
5 13 772.84 40 13.25 1454 771 4.60 / 549.94 2 3
6 8 0.00 175 14.10 322 795 5.40 / 550.73 2 15
Average= 4.87 (KJ/cycle)

Cycle 111 GMT 2/ 5/2018 20:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 29 14.19 486 200 0.20 / 540.36 2 2
2 3 970.20 -1 14.19 486 0 0.00 / 540.36 2 2
3 3 1030.76 1 12.16 1816 22 0.22 / 540.38 2 2
4 12 1145.00 6 12.16 1935 141 0.36 / 540.52 2 2
5 7 2002.00 62 10.91 3110 2104 2.47 / 542.62 2 2
6 13 1563.52 40 12.45 2529 1259 3.73 / 543.88 2 2
7 13 601.00 40 13.47 1186 639 4.37 / 544.52 2 3
8 8 0.00 175 14.10 330 814 5.18 / 545.34 2 9
Average= 4.87 (KJ/cycle)

Cycle 110 GMT 22/ 4/2018 21: 3: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 29 14.20 472 194 0.19 / 535.07 2 2
2 12 1112.24 3 12.16 1905 69 0.26 / 535.14 2 2
3 7 2001.64 58 10.92 3126 1980 2.24 / 537.12 2 2
4 13 1789.84 33 12.35 2878 1173 3.42 / 538.29 2 2
5 13 1052.96 33 13.11 1836 794 4.21 / 539.09 2 3
6 13 141.12 33 14.04 549 254 4.47 / 539.34 2 4
7 8 0.12 175 14.12 330 815 5.28 / 540.16 2 15
Average= 4.87 (KJ/cycle)

Cycle 109 GMT 12/ 4/2018 21:26: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 29 14.23 484 200 0.20 / 529.76 2 2
2 12 1124.84 3 12.20 1919 70 0.27 / 529.83 2 2
3 7 2006.68 59 10.97 3100 2006 2.28 / 531.83 2 2
4 13 1800.24 33 12.35 2881 1174 3.45 / 533.01 2 2
5 13 1068.32 33 13.09 1852 800 4.25 / 533.81 2 3
6 13 148.00 33 14.04 557 258 4.51 / 534.06 2 4
7 8 0.08 175 14.11 329 812 5.32 / 534.88 2 16
Average= 4.86 (KJ/cycle)

Cycle 108 GMT 2/ 4/2018 21:58: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 29 14.21 476 196 0.20 / 524.66 2 2
2 12 1123.44 3 12.11 1925 70 0.27 / 524.73 2 2
3 7 2003.48 59 11.00 3119 2024 2.29 / 526.75 2 2
4 13 1594.44 33 12.56 2578 1069 3.36 / 527.82 2 2
5 13 898.96 33 13.24 1629 712 4.07 / 528.53 2 3
6 13 92.12 33 14.10 475 221 4.29 / 528.75 2 4
7 8 0.04 175 14.11 326 805 5.10 / 529.56 2 17
Average= 4.86 (KJ/cycle)

Cycle 107 GMT 23/ 3/2018 22:14: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 29 14.24 473 195 0.20 / 519.49 2 2
2 12 1120.08 3 12.11 1927 70 0.27 / 519.56 2 2
3 7 2003.44 58 11.05 3113 1995 2.26 / 521.55 2 2
4 13 1784.44 33 12.39 2849 1165 3.43 / 522.72 2 2
5 13 830.56 33 13.31 1525 670 4.10 / 523.39 2 3
6 13 152.48 33 14.02 563 260 4.36 / 523.65 2 4
7 8 0.12 175 14.10 329 812 5.17 / 524.46 2 15
Average= 4.86 (KJ/cycle)

Cycle 106 GMT 13/ 3/2018 22:48: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 29 14.26 475 196 0.20 / 514.28 2 2
2 12 1120.52 3 12.25 1910 70 0.27 / 514.35 2 2
3 7 2006.20 58 11.07 3122 2005 2.27 / 516.35 2 2
4 13 1790.60 33 12.39 2858 1169 3.44 / 517.52 2 2
5 13 853.28 33 13.29 1570 689 4.13 / 518.21 2 3
6 13 166.56 33 14.01 586 271 4.40 / 518.48 2 4
7 8 0.12 175 14.11 329 812 5.21 / 519.29 2 17
Average= 4.85 (KJ/cycle)

Cycle 105 GMT 3/ 3/2018 23:13: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 29 14.24 483 199 0.20 / 509.13 2 2
2 12 1112.04 3 12.29 1897 70 0.27 / 509.20 2 2
3 7 2008.12 58 11.12 3105 2003 2.27 / 511.21 2 2
4 13 1790.68 33 12.41 2876 1178 3.45 / 512.38 2 2
5 13 850.60 33 13.30 1546 679 4.13 / 513.06 2 3
6 13 87.40 33 14.12 465 217 4.35 / 513.28 2 4
7 8 0.20 175 14.12 324 801 5.15 / 514.08 2 18
Average= 4.85 (KJ/cycle)

Cycle 104 GMT 21/ 2/2018 23:39: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 29 14.26 485 201 0.20 / 503.99 2 2
2 12 1113.16 3 12.29 1907 70 0.27 / 504.06 2 2
3 7 2003.64 58 11.14 3111 2010 2.28 / 506.07 2 2
4 13 1792.92 33 12.42 2870 1176 3.46 / 507.24 2 2
5 13 842.04 33 13.30 1552 681 4.14 / 507.92 2 3
6 13 79.76 33 14.13 457 213 4.35 / 508.14 2 4
7 8 -0.04 175 14.13 323 799 5.15 / 508.94 2 18
Average= 4.85 (KJ/cycle)

Cycle 103 GMT 12/ 2/2018 0: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 28 14.21 485 193 0.19 / 498.64 2 2
2 12 1136.52 3 12.27 1949 72 0.26 / 498.71 2 2
3 7 2007.36 58 11.19 3131 2032 2.30 / 500.75 2 2
4 13 1788.60 33 12.43 2866 1176 3.47 / 501.92 2 2
5 13 1055.12 33 13.13 1839 797 4.27 / 502.72 2 3
6 13 133.24 33 14.05 539 250 4.52 / 502.97 2 4
7 8 0.32 175 14.11 331 817 5.34 / 503.78 2 20
Average= 4.84 (KJ/cycle)

Cycle 102 GMT 2/ 2/2018 0:38: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 28 14.25 488 195 0.19 / 493.41 2 2
2 12 1127.88 3 12.22 1952 72 0.27 / 493.49 2 2
3 7 2002.72 59 11.20 3114 2058 2.32 / 495.54 2 2
4 13 1790.68 33 12.43 2892 1186 3.51 / 496.73 2 2
5 13 844.24 33 13.31 1555 683 4.19 / 497.41 2 3
6 13 83.64 33 14.12 469 219 4.41 / 497.63 2 4
7 8 0.08 175 14.11 331 817 5.23 / 498.45 2 19
Average= 4.84 (KJ/cycle)

Cycle 101 GMT 23/ 1/2018 1: 1: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 28 14.24 498 199 0.20 / 488.20 2 2
2 12 1126.92 3 12.18 1934 71 0.27 / 488.27 2 2
3 7 2008.64 59 11.20 3129 2068 2.34 / 490.33 2 2
4 13 1798.48 33 12.44 2893 1188 3.52 / 491.52 2 2
5 13 838.36 33 13.32 1539 676 4.20 / 492.20 2 3
6 13 74.00 33 14.14 447 209 4.41 / 492.41 2 4
7 8 0.00 175 14.10 329 812 5.22 / 493.22 2 15
Average= 4.84 (KJ/cycle)

Cycle 100 GMT 13/ 1/2018 1:30: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 28 14.25 485 194 0.19 / 483.08 2 2
2 12 1126.36 3 12.19 1932 71 0.26 / 483.15 2 2
3 7 2009.00 58 11.23 3121 2033 2.30 / 485.19 2 2
4 13 1593.28 33 12.64 2579 1076 3.37 / 486.26 2 2
5 13 902.24 33 13.28 1623 711 4.08 / 486.97 2 3
6 13 68.64 33 14.15 439 205 4.29 / 487.18 2 4
7 8 0.32 175 14.09 332 819 5.11 / 488.00 2 18
Average= 4.83 (KJ/cycle)

Cycle 99 GMT 3/ 1/2018 1:51: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 28 14.21 491 195 0.20 / 477.94 2 2
2 12 1131.32 3 12.25 1935 71 0.27 / 478.01 2 2
3 7 2007.08 59 11.28 3124 2079 2.35 / 480.09 2 2
4 13 1594.40 33 12.67 2579 1078 3.42 / 481.17 2 2
5 13 879.88 33 13.31 1591 699 4.12 / 481.87 2 3
6 13 84.68 33 14.12 462 215 4.34 / 482.08 2 4
7 8 -0.04 175 14.10 328 809 5.15 / 482.89 2 14
Average= 4.83 (KJ/cycle)

Cycle 98 GMT 24/12/2017 2:14: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 28 14.21 496 197 0.20 / 472.62 2 2
2 12 1118.80 3 12.12 1919 70 0.27 / 472.69 2 2
3 7 2008.68 58 11.26 3115 2034 2.30 / 474.72 2 2
4 13 1791.32 33 12.49 2871 1183 3.48 / 475.91 2 2
5 13 1027.60 33 13.19 1792 780 4.26 / 476.69 2 3
6 13 112.52 33 14.08 499 232 4.50 / 476.92 2 4
7 8 0.04 175 14.08 335 825 5.32 / 477.74 2 14
Average= 4.83 (KJ/cycle)

Cycle 97 GMT 14/12/2017 3: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 28 14.23 502 200 0.20 / 467.47 2 2
2 12 1126.16 3 12.24 1923 71 0.27 / 467.54 2 2
3 7 2004.84 59 11.30 3119 2079 2.35 / 469.62 2 2
4 13 1582.60 33 12.69 2571 1077 3.43 / 470.70 2 2
5 13 869.40 33 13.31 1581 694 4.12 / 471.39 2 3
6 13 77.40 33 14.13 458 214 4.33 / 471.60 2 4
7 8 -0.08 175 14.09 331 816 5.15 / 472.42 2 17
Average= 4.82 (KJ/cycle)

Cycle 96 GMT 4/12/2017 3:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 28 14.26 490 196 0.20 / 462.29 2 2
2 12 1117.04 3 12.16 1897 69 0.26 / 462.36 2 2
3 7 2007.52 59 11.29 3137 2090 2.35 / 464.45 2 2
4 13 1591.52 33 12.70 2563 1074 3.43 / 465.53 2 2
5 13 885.04 33 13.31 1600 703 4.13 / 466.23 2 3
6 13 81.24 33 14.13 463 216 4.35 / 466.44 2 4
7 8 0.04 175 14.09 335 826 5.17 / 467.27 2 16
Average= 4.82 (KJ/cycle)

Cycle 95 GMT 24/11/2017 3:48: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 28 14.18 500 199 0.20 / 457.14 2 2
2 12 1128.24 3 12.16 1923 70 0.27 / 457.21 2 2
3 7 2006.04 59 11.34 3130 2094 2.36 / 459.31 2 2
4 13 1582.60 33 12.72 2553 1072 3.43 / 460.38 2 2
5 13 857.20 33 13.34 1565 689 4.12 / 461.07 2 3
6 13 72.72 33 14.14 448 209 4.33 / 461.28 2 4
7 8 0.28 175 14.09 332 819 5.15 / 462.10 2 15
Average= 4.81 (KJ/cycle)

Cycle 94 GMT 14/11/2017 4:21: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 28 14.22 497 198 0.20 / 452.03 2 2
2 12 1127.24 3 12.00 1922 69 0.27 / 452.10 2 2
3 7 2001.24 58 11.40 3115 2060 2.33 / 454.16 2 2
4 13 1589.28 33 12.73 2569 1079 3.41 / 455.24 2 2
5 13 869.08 33 13.32 1576 693 4.10 / 455.93 2 3
6 13 75.88 33 14.15 445 208 4.31 / 456.14 2 4
7 8 0.20 175 14.09 328 809 5.12 / 456.95 2 14
Average= 4.81 (KJ/cycle)

Cycle 93 GMT 4/11/2017 5: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 27 14.21 514 197 0.20 / 446.75 2 2
2 12 1132.80 3 12.15 1931 70 0.27 / 446.82 2 2
3 7 2001.20 59 11.45 3116 2105 2.37 / 448.93 2 2
4 13 1784.40 33 12.54 2869 1187 3.56 / 450.12 2 2
5 13 830.04 33 13.36 1538 678 4.24 / 450.79 2 3
6 13 69.16 33 14.15 445 208 4.45 / 451.00 2 4
7 8 -0.04 175 14.08 336 828 5.27 / 451.83 2 11
Average= 4.81 (KJ/cycle)

Cycle 92 GMT 25/10/2017 5:38: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 27 14.19 493 189 0.19 / 441.41 2 2
2 12 1110.36 3 11.84 1884 67 0.26 / 441.48 2 2
3 7 2001.84 58 11.34 3119 2051 2.31 / 443.53 2 2
4 13 1781.88 33 12.54 2848 1179 3.49 / 444.71 2 2
5 13 1033.08 33 13.19 1814 790 4.28 / 445.49 2 3
6 13 112.72 33 14.08 505 235 4.51 / 445.73 2 4
7 8 0.20 175 14.07 336 827 5.34 / 446.56 2 12
Average= 4.80 (KJ/cycle)

Cycle 91 GMT 15/10/2017 6:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 28 14.20 502 200 0.20 / 436.21 2 2
2 3 972.68 -1 14.20 502 0 0.00 / 436.21 2 2
3 3 1040.28 1 12.90 1813 23 0.22 / 436.23 2 2
4 12 1142.64 3 12.00 1953 70 0.29 / 436.30 2 2
5 7 2005.16 58 11.43 3141 2082 2.38 / 438.38 2 2
6 13 1582.92 33 12.73 2565 1078 3.45 / 439.46 2 2
7 13 868.08 33 13.32 1598 702 4.16 / 440.16 2 3
8 13 77.16 33 14.14 459 214 4.37 / 440.38 2 4
9 8 0.28 175 14.06 342 841 5.21 / 441.22 2 16
Average= 4.80 (KJ/cycle)

Cycle 90 GMT 5/10/2017 6:42: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 28 14.20 506 201 0.20 / 430.97 2 2
2 12 1115.20 3 11.81 1919 68 0.27 / 431.03 2 2
3 7 2002.88 59 11.40 3117 2096 2.37 / 433.13 2 2
4 13 1781.92 33 12.55 2859 1184 3.55 / 434.31 2 2
5 13 799.76 33 13.39 1494 660 4.21 / 434.97 2 3
6 13 70.08 33 14.15 449 210 4.42 / 435.18 2 4
7 8 -0.20 175 14.06 335 824 5.24 / 436.01 2 23
Average= 4.79 (KJ/cycle)

Cycle 89 GMT 25/ 9/2017 7:14: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 28 14.24 513 205 0.20 / 425.84 2 2
2 12 1108.40 3 11.57 1891 66 0.27 / 425.91 2 2
3 7 2001.64 58 11.41 3131 2072 2.34 / 427.98 2 2
4 13 1576.20 33 12.76 2533 1067 3.41 / 429.05 2 2
5 13 870.80 33 13.35 1572 693 4.10 / 429.74 2 3
6 13 74.84 33 14.14 453 211 4.31 / 429.95 2 4
7 8 0.12 175 14.08 330 813 5.13 / 430.76 2 16
Average= 4.79 (KJ/cycle)

Cycle 88 GMT 15/ 9/2017 7:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 27 14.25 506 195 0.19 / 420.61 2 2
2 12 1128.20 3 11.74 1944 68 0.26 / 420.68 2 2
3 7 2004.12 58 11.45 3117 2070 2.33 / 422.75 2 2
4 13 1787.56 33 12.57 2862 1187 3.52 / 423.94 2 2
5 13 841.56 33 13.36 1551 684 4.20 / 424.62 2 3
6 13 45.72 33 14.18 410 192 4.40 / 424.81 2 4
7 8 0.20 175 14.05 336 826 5.22 / 425.64 2 13
Average= 4.78 (KJ/cycle)

Cycle 87 GMT 5/ 9/2017 8:13: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 28 14.23 488 194 0.19 / 415.38 2 2
2 3 972.08 -1 14.23 488 0 0.00 / 415.38 2 2
3 3 1032.64 1 12.70 1819 23 0.22 / 415.41 2 2
4 12 1141.40 3 11.57 1940 67 0.28 / 415.47 2 2
5 7 2001.56 58 11.38 3127 2064 2.35 / 417.54 2 2
6 13 1782.16 33 12.58 2841 1179 3.53 / 418.72 2 2
7 13 818.04 33 13.38 1517 670 4.20 / 419.39 2 3
8 13 72.76 33 14.15 447 209 4.41 / 419.60 2 5
9 8 0.16 175 14.09 333 821 5.23 / 420.42 2 15
Average= 4.78 (KJ/cycle)

Cycle 86 GMT 26/ 8/2017 8:58: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 28 14.25 509 203 0.20 / 410.01 2 2
2 12 1103.08 3 11.39 1871 64 0.27 / 410.07 2 2
3 7 2007.12 59 11.32 3132 2092 2.36 / 412.16 2 2
4 13 1788.92 33 12.58 2845 1181 3.54 / 413.35 2 2
5 13 1041.60 33 13.21 1810 789 4.33 / 414.13 2 3
6 13 116.56 33 14.10 502 234 4.56 / 414.37 2 4
7 8 -0.04 175 14.08 333 821 5.38 / 415.19 2 15
Average= 4.77 (KJ/cycle)

Cycle 85 GMT 16/ 8/2017 9:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 28 14.24 496 198 0.20 / 404.85 2 2
2 12 1108.72 3 11.50 1889 65 0.26 / 404.91 2 2
3 7 2001.40 59 11.33 3108 2078 2.34 / 406.99 2 2
4 13 1578.44 33 12.76 2557 1077 3.42 / 408.07 2 2
5 13 865.84 33 13.36 1578 696 4.11 / 408.76 2 3
6 13 74.68 33 14.16 453 212 4.32 / 408.98 2 4
7 8 0.08 175 14.08 337 830 5.15 / 409.81 2 13
Average= 4.77 (KJ/cycle)

Cycle 84 GMT 6/ 8/2017 9:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 27 14.23 509 196 0.20 / 399.69 2 2
2 12 1126.76 3 11.54 1901 66 0.26 / 399.75 2 2
3 7 2004.08 59 11.38 3122 2096 2.36 / 401.85 2 2
4 13 1584.76 33 12.79 2554 1078 3.44 / 402.93 2 2
5 13 859.40 33 13.38 1564 691 4.13 / 403.62 2 3
6 13 68.48 33 14.17 446 209 4.33 / 403.82 2 4
7 8 0.16 175 14.05 336 826 5.16 / 404.65 2 15
Average= 4.76 (KJ/cycle)

Cycle 83 GMT 27/ 7/2017 10:14: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 28 14.25 498 199 0.20 / 394.51 2 2
2 3 973.48 -1 14.25 498 0 0.00 / 394.51 2 2
3 3 1030.48 1 12.95 1815 24 0.22 / 394.53 2 2
4 12 1143.64 3 11.39 1928 66 0.29 / 394.60 2 2
5 7 2000.60 58 11.36 3121 2056 2.34 / 396.65 2 2
6 13 1589.76 33 12.77 2584 1089 3.43 / 397.74 2 2
7 13 863.16 33 13.37 1587 700 4.13 / 398.44 2 3
8 13 73.00 33 14.16 459 214 4.35 / 398.66 2 5
9 8 -0.24 175 14.05 339 834 5.18 / 399.49 2 19
Average= 4.76 (KJ/cycle)

Cycle 82 GMT 17/ 7/2017 10:32: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 28 14.28 495 198 0.20 / 389.33 2 2
2 3 972.12 -1 14.28 495 0 0.00 / 389.33 2 2
3 3 1036.48 1 13.13 1813 24 0.22 / 389.35 2 2
4 12 1149.00 3 11.22 1934 65 0.29 / 389.42 2 2
5 7 2001.20 58 11.34 3123 2054 2.34 / 391.47 2 2
6 13 1580.48 33 12.78 2566 1082 3.42 / 392.55 2 2
7 13 863.08 33 13.39 1586 701 4.12 / 393.25 2 3
8 13 82.96 33 14.16 471 220 4.34 / 393.47 2 5
9 8 0.32 175 14.09 339 836 5.18 / 394.31 2 16
Average= 4.75 (KJ/cycle)

Cycle 81 GMT 7/ 7/2017 10:56: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 27 14.26 510 196 0.20 / 384.06 2 2
2 3 1020.80 1 11.64 1797 21 0.22 / 384.08 2 2
3 12 1132.96 3 11.37 1917 65 0.28 / 384.15 2 2
4 7 2005.68 59 11.35 3106 2080 2.36 / 386.23 2 2
5 13 1784.68 33 12.62 2841 1183 3.55 / 387.41 2 2
6 13 834.24 33 13.41 1528 676 4.22 / 388.08 2 3
7 13 79.64 33 14.18 458 214 4.44 / 388.30 2 5
8 8 0.08 175 14.10 336 829 5.27 / 389.13 2 19
Average= 4.75 (KJ/cycle)

Cycle 80 GMT 27/ 6/2017 11:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 27 14.27 510 196 0.20 / 378.84 2 2
2 12 1126.08 3 11.04 1900 63 0.26 / 378.90 2 2
3 7 2004.76 59 11.22 3112 2060 2.32 / 380.96 2 2
4 13 1789.20 33 12.61 2870 1194 3.51 / 382.16 2 2
5 13 814.96 33 13.42 1502 665 4.18 / 382.82 2 3
6 13 75.48 33 14.18 458 214 4.39 / 383.04 2 5
7 8 -0.04 175 14.07 335 825 5.22 / 383.86 2 16
Average= 4.74 (KJ/cycle)

Cycle 79 GMT 17/ 6/2017 11:47: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 27 14.28 493 190 0.19 / 373.70 2 2
2 12 1122.72 3 11.05 1899 63 0.25 / 373.76 2 2
3 7 2003.36 59 11.20 3141 2076 2.33 / 375.84 2 2
4 13 1591.96 33 12.81 2570 1086 3.42 / 376.92 2 2
5 13 880.64 33 13.38 1598 706 4.12 / 377.63 2 3
6 13 39.44 33 14.24 399 187 4.31 / 377.82 2 5
7 8 0.16 175 14.05 337 829 5.14 / 378.64 2 20
Average= 4.73 (KJ/cycle)

Cycle 78 GMT 7/ 6/2017 12: 6: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 27 14.30 495 191 0.19 / 368.64 2 2
2 12 1123.00 3 11.45 1910 66 0.26 / 368.71 2 2
3 7 2001.24 58 11.20 3112 2022 2.28 / 370.73 2 2
4 13 1580.32 33 12.82 2529 1070 3.35 / 371.80 2 2
5 13 864.76 33 13.41 1574 697 4.04 / 372.49 2 3
6 13 36.00 33 14.23 400 188 4.23 / 372.68 2 4
7 8 0.24 175 14.04 336 826 5.06 / 373.51 2 19
Average= 4.73 (KJ/cycle)

Cycle 77 GMT 28/ 5/2017 12:29: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 28 14.33 501 201 0.20 / 363.48 2 2
2 3 972.08 -1 14.33 501 0 0.00 / 363.48 2 2
3 3 1030.04 1 12.84 1823 23 0.22 / 363.50 2 2
4 12 1144.12 3 11.61 1954 68 0.29 / 363.57 2 2
5 7 2005.68 59 11.20 3127 2066 2.36 / 365.64 2 2
6 13 1576.28 33 12.82 2545 1077 3.44 / 366.71 2 2
7 13 864.68 33 13.41 1574 697 4.13 / 367.41 2 3
8 13 72.88 33 14.19 453 212 4.34 / 367.62 2 5
9 8 0.12 175 14.10 335 827 5.17 / 368.45 2 17
Average= 4.72 (KJ/cycle)

Cycle 76 GMT 18/ 5/2017 12:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 28 14.33 490 197 0.20 / 358.36 2 2
2 12 1106.48 3 11.48 1888 65 0.26 / 358.42 2 2
3 7 2006.68 58 11.23 3110 2026 2.29 / 360.45 2 2
4 13 1585.20 33 12.82 2582 1092 3.38 / 361.54 2 2
5 13 855.96 33 13.43 1569 695 4.08 / 362.24 2 3
6 13 73.64 33 14.20 454 213 4.29 / 362.45 2 5
7 8 -0.04 175 14.09 336 828 5.12 / 363.28 2 17
Average= 4.72 (KJ/cycle)

Cycle 75 GMT 8/ 5/2017 13: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 28 14.36 487 196 0.20 / 353.28 2 2
2 12 1110.60 3 11.73 1918 67 0.26 / 353.34 2 2
3 7 2002.88 58 11.26 3109 2030 2.29 / 355.37 2 2
4 13 1591.24 33 12.84 2587 1096 3.39 / 356.47 2 2
5 13 871.80 33 13.44 1574 698 4.09 / 357.17 2 3
6 13 35.96 33 14.26 387 182 4.27 / 357.35 2 5
7 8 0.24 175 14.06 330 812 5.08 / 358.16 2 21
Average= 4.71 (KJ/cycle)

Cycle 74 GMT 28/ 4/2017 13:27: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 28 14.36 487 196 0.20 / 348.43 2 2
2 7 2009.04 50 11.22 3117 1749 1.94 / 350.17 2 2
3 13 1630.64 32 12.86 2635 1084 3.03 / 351.26 2 2
4 13 978.96 32 13.39 1739 745 3.77 / 352.00 2 3
5 13 124.16 32 14.15 535 242 4.02 / 352.25 2 4
6 8 0.12 175 14.11 338 835 4.85 / 353.08 2 14
Average= 4.71 (KJ/cycle)

Cycle 73 GMT 18/ 4/2017 13:35: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 28 14.35 506 203 0.20 / 343.49 2 2
2 7 2001.36 51 11.25 3115 1787 1.99 / 345.28 2 2
3 13 1816.16 32 12.70 2909 1182 3.17 / 346.46 2 2
4 13 938.16 32 13.41 1677 720 3.89 / 347.18 2 3
5 13 116.48 32 14.17 515 234 4.13 / 347.41 2 4
6 8 0.04 175 14.13 330 816 4.94 / 348.23 2 13
Average= 4.71 (KJ/cycle)

Cycle 72 GMT 8/ 4/2017 13:51: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 28 14.34 493 198 0.20 / 338.56 2 2
2 7 2007.80 50 11.27 3111 1753 1.95 / 340.31 2 2
3 13 1808.00 32 12.72 2911 1185 3.14 / 341.50 2 2
4 13 917.24 32 13.43 1664 715 3.85 / 342.21 2 3
5 13 109.40 32 14.17 517 234 4.09 / 342.45 2 4
6 8 0.04 175 14.11 341 842 4.93 / 343.29 2 18
Average= 4.70 (KJ/cycle)

Cycle 71 GMT 29/ 3/2017 14: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 28 14.36 492 198 0.20 / 333.61 2 2
2 7 2009.36 51 11.31 3129 1805 2.00 / 335.42 2 2
3 13 1816.00 32 12.73 2883 1174 3.18 / 336.59 2 2
4 13 928.60 32 13.42 1660 713 3.89 / 337.30 2 3
5 13 110.80 32 14.15 520 235 4.13 / 337.54 2 4
6 8 0.24 175 14.12 333 823 4.95 / 338.36 2 17
Average= 4.70 (KJ/cycle)

Cycle 70 GMT 19/ 3/2017 14: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 28 14.34 487 196 0.20 / 328.77 2 2
2 7 2006.28 50 11.37 3132 1781 1.98 / 330.56 2 2
3 13 1622.80 32 12.92 2618 1082 3.06 / 331.64 2 2
4 13 951.40 32 13.43 1689 726 3.78 / 332.36 2 3
5 13 110.88 32 14.18 504 229 4.01 / 332.59 2 4
6 8 0.08 175 14.12 332 820 4.83 / 333.41 2 14
Average= 4.70 (KJ/cycle)

Cycle 69 GMT 9/ 3/2017 14:25: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 28 14.43 487 197 0.20 / 323.88 2 2
2 7 2008.76 50 11.45 3146 1801 2.00 / 325.68 2 2
3 13 1636.52 32 12.94 2615 1083 3.08 / 326.77 2 2
4 13 972.12 32 13.43 1724 741 3.82 / 327.51 2 3
5 13 115.80 32 14.18 529 240 4.06 / 327.75 2 4
6 8 0.28 175 14.10 337 832 4.89 / 328.58 2 13
Average= 4.69 (KJ/cycle)

Cycle 68 GMT 27/ 2/2017 14:39: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 28 14.34 491 197 0.20 / 318.92 2 2
2 7 2004.40 50 11.59 3142 1821 2.02 / 320.75 2 2
3 13 1817.64 32 12.78 2893 1183 3.20 / 321.93 2 2
4 13 914.92 32 13.48 1649 711 3.91 / 322.64 2 3
5 13 104.68 32 14.19 506 230 4.14 / 322.87 2 4
6 8 0.12 175 14.13 330 816 4.96 / 323.69 2 19
Average= 4.69 (KJ/cycle)

Cycle 67 GMT 17/ 2/2017 14:57: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 27 14.41 496 193 0.19 / 314.12 2 2
2 7 2007.24 50 11.67 3148 1837 2.03 / 315.96 2 2
3 13 1618.56 32 12.96 2615 1084 3.11 / 317.04 2 2
4 13 764.84 32 13.62 1425 621 3.74 / 317.67 2 3
5 13 135.24 32 14.18 550 250 3.98 / 317.91 2 4
6 8 0.48 175 14.12 329 813 4.80 / 318.73 2 18
Average= 4.69 (KJ/cycle)

Cycle 66 GMT 7/ 2/2017 15: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 27 14.37 495 192 0.19 / 309.13 2 2
2 7 2002.72 51 11.73 3133 1874 2.07 / 311.00 2 2
3 13 1818.72 32 12.82 2877 1180 3.25 / 312.18 2 2
4 13 910.92 32 13.50 1639 708 3.95 / 312.89 2 3
5 13 94.48 32 14.22 487 222 4.18 / 313.11 2 4
6 8 0.12 175 14.13 330 816 4.99 / 313.93 2 20
Average= 4.69 (KJ/cycle)

Cycle 65 GMT 28/ 1/2017 15:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 27 14.37 484 188 0.19 / 304.15 2 2
2 7 2004.92 51 11.78 3140 1886 2.07 / 306.03 2 2
3 13 1627.12 32 12.97 2627 1090 3.16 / 307.12 2 2
4 13 790.44 32 13.61 1473 642 3.81 / 307.76 2 3
5 13 68.44 32 14.25 449 205 4.01 / 307.97 2 4
6 13 14.72 32 14.23 368 168 4.18 / 308.14 2 5
7 8 -0.04 175 14.05 326 802 4.98 / 308.94 2 15
Average= 4.68 (KJ/cycle)

Cycle 64 GMT 18/ 1/2017 15:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 27 14.38 495 192 0.19 / 299.21 2 2
2 7 2003.44 51 11.85 3128 1890 2.08 / 301.11 2 2
3 13 1606.28 32 13.01 2602 1083 3.17 / 302.19 2 2
4 13 939.56 32 13.51 1680 726 3.89 / 302.91 2 3
5 13 95.56 32 14.22 488 222 4.11 / 303.14 2 4
6 8 0.24 175 14.13 332 821 4.94 / 303.96 2 15
Average= 4.68 (KJ/cycle)

Cycle 63 GMT 8/ 1/2017 15:34: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 27 14.35 513 199 0.20 / 294.43 2 2
2 7 2001.36 50 11.94 3118 1861 2.06 / 296.29 2 2
3 13 1613.04 32 13.03 2606 1087 3.15 / 297.38 2 2
4 13 762.04 32 13.66 1423 622 3.77 / 298.00 2 3
5 13 61.60 32 14.28 439 201 3.97 / 298.20 2 4
6 8 0.20 175 14.13 333 823 4.79 / 299.02 2 16
Average= 4.67 (KJ/cycle)

Cycle 62 GMT 29/12/2016 15:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 27 14.37 500 194 0.19 / 289.60 2 2
2 7 2001.44 50 12.00 3140 1884 2.08 / 291.49 2 2
3 13 1614.60 32 13.03 2613 1090 3.17 / 292.58 2 2
4 13 747.48 32 13.67 1411 617 3.78 / 293.19 2 3
5 13 64.24 32 14.27 447 204 3.99 / 293.40 2 4
6 8 0.20 175 14.09 337 831 4.82 / 294.23 2 16
Average= 4.67 (KJ/cycle)

Cycle 61 GMT 19/12/2016 15:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 27 14.41 488 190 0.19 / 284.66 2 2
2 7 2009.96 50 12.05 3149 1897 2.09 / 286.56 2 2
3 13 1602.32 32 13.06 2604 1088 3.18 / 287.65 2 2
4 13 928.76 32 13.56 1664 722 3.90 / 288.37 2 3
5 13 81.72 32 14.25 471 215 4.11 / 288.58 2 4
6 8 0.12 175 14.14 334 826 4.94 / 289.41 2 17
Average= 4.67 (KJ/cycle)

Cycle 60 GMT 9/12/2016 16:21: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 27 14.35 508 197 0.20 / 279.60 2 2
2 7 2001.28 51 12.13 3130 1936 2.13 / 281.53 2 2
3 13 1801.32 32 12.92 2872 1187 3.32 / 282.72 2 2
4 13 889.84 32 13.58 1619 704 4.02 / 283.42 2 3
5 13 87.04 32 14.25 479 218 4.24 / 283.64 2 4
6 8 0.08 175 14.15 335 830 5.07 / 284.47 2 14
Average= 4.66 (KJ/cycle)

Cycle 59 GMT 29/11/2016 16:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 27 14.38 497 193 0.19 / 274.73 2 2
2 7 2001.80 51 12.19 3128 1945 2.14 / 276.67 2 2
3 13 1610.84 32 13.10 2607 1093 3.23 / 277.77 2 2
4 13 747.88 32 13.70 1407 617 3.85 / 278.38 2 3
5 13 60.12 32 14.29 436 199 4.05 / 278.58 2 5
6 8 -0.04 175 14.12 331 818 4.86 / 279.40 2 16
Average= 4.66 (KJ/cycle)

Cycle 58 GMT 19/11/2016 16:52:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 27 14.37 510 198 0.20 / 269.89 2 2
2 7 2002.32 50 12.26 3137 1923 2.12 / 271.82 2 2
3 13 1603.28 32 13.11 2580 1082 3.20 / 272.90 2 2
4 13 736.64 32 13.71 1400 614 3.82 / 273.51 2 3
5 13 52.56 32 14.31 430 197 4.01 / 273.71 2 5
6 8 0.16 175 14.11 334 825 4.84 / 274.53 2 18
Average= 4.65 (KJ/cycle)

Cycle 57 GMT 9/11/2016 17:13: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 27 14.39 503 195 0.20 / 265.20 2 2
2 7 2009.64 50 12.31 3154 1941 2.14 / 267.14 2 2
3 13 1608.60 32 13.10 2624 1100 3.24 / 268.24 2 2
4 13 744.44 32 13.72 1410 619 3.86 / 268.86 2 3
5 8 0.40 175 14.17 338 838 4.69 / 269.70 2 15
Average= 4.65 (KJ/cycle)

Cycle 56 GMT 30/10/2016 17:24: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 27 14.39 513 199 0.20 / 260.33 2 2
2 7 2008.48 50 12.38 3154 1952 2.15 / 262.28 2 2
3 13 1612.68 32 13.12 2619 1100 3.25 / 263.38 2 2
4 13 742.72 32 13.72 1408 618 3.87 / 264.00 2 3
5 13 23.32 32 14.34 380 174 4.04 / 264.18 2 5
6 8 -0.12 175 14.11 334 825 4.87 / 265.00 2 15
Average= 4.65 (KJ/cycle)

Cycle 55 GMT 20/10/2016 17:26: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 27 14.36 510 198 0.20 / 255.46 2 2
2 7 2006.72 50 12.41 3143 1950 2.15 / 257.41 2 2
3 13 1610.52 32 13.14 2610 1097 3.25 / 258.51 2 2
4 13 722.04 32 13.74 1371 603 3.85 / 259.11 2 3
5 13 22.08 32 14.35 387 178 4.03 / 259.29 2 4
6 8 0.28 175 14.10 342 844 4.87 / 260.13 2 13
Average= 4.65 (KJ/cycle)

Cycle 54 GMT 10/10/2016 17:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 28 14.36 525 211 0.21 / 250.43 2 2
2 3 970.36 -1 14.36 525 0 0.00 / 250.43 2 2
3 3 1035.24 1 13.83 1853 26 0.24 / 250.45 2 2
4 7 2002.60 50 12.45 3127 1947 2.18 / 252.40 2 2
5 13 1596.80 32 13.13 2606 1095 3.28 / 253.49 2 2
6 13 702.08 32 13.76 1336 588 3.87 / 254.08 2 3
7 13 23.76 32 14.35 386 177 4.04 / 254.26 2 5
8 13 12.36 32 14.24 369 168 4.21 / 254.43 2 6
9 8 -0.16 175 14.08 339 835 5.05 / 255.26 3 19
Average= 4.64 (KJ/cycle)

Cycle 53 GMT 30/ 9/2016 17:57: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 27 14.41 514 200 0.20 / 245.44 2 2
2 7 2001.76 50 12.45 3151 1961 2.16 / 247.41 2 2
3 13 1595.56 32 13.15 2572 1082 3.24 / 248.49 2 2
4 13 901.36 32 13.61 1636 713 3.96 / 249.20 2 3
5 13 3.44 32 14.36 367 169 4.12 / 249.37 2 4
6 8 0.20 175 14.11 343 847 4.97 / 250.22 2 16
Average= 4.63 (KJ/cycle)

Cycle 52 GMT 20/ 9/2016 18:22:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 27 14.40 489 190 0.19 / 240.72 2 2
2 7 2004.36 51 12.48 3152 2006 2.20 / 242.72 2 2
3 13 1595.00 32 13.16 2584 1088 3.28 / 243.81 2 2
4 13 709.16 32 13.77 1351 595 3.88 / 244.41 2 4
5 8 -0.08 175 14.18 337 836 4.72 / 245.24 2 12
Average= 4.63 (KJ/cycle)

Cycle 51 GMT 10/ 9/2016 18:34:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 27 14.42 509 198 0.20 / 235.75 2 2
2 7 2008.20 50 12.48 3152 1967 2.17 / 237.72 2 2
3 13 1601.16 32 13.16 2571 1083 3.25 / 238.80 2 2
4 13 918.60 32 13.60 1662 723 3.97 / 239.52 2 4
5 13 4.32 32 14.38 361 166 4.14 / 239.69 2 7
6 8 0.04 175 14.12 339 838 4.97 / 240.53 2 16
Average= 4.63 (KJ/cycle)

Cycle 50 GMT 31/ 8/2016 18:48: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 27 14.41 501 195 0.19 / 230.91 2 2
2 7 2000.96 50 12.45 3144 1957 2.15 / 232.87 2 2
3 13 1600.40 32 13.15 2565 1079 3.23 / 233.95 2 3
4 13 727.80 32 13.75 1383 609 3.84 / 234.56 2 3
5 13 22.32 32 14.37 382 176 4.02 / 234.73 2 5
6 8 0.32 175 14.14 332 822 4.84 / 235.55 2 16
Average= 4.62 (KJ/cycle)

Cycle 49 GMT 21/ 8/2016 18:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 27 14.43 504 196 0.20 / 226.05 2 2
2 7 2001.80 50 12.43 3144 1954 2.15 / 228.00 2 2
3 13 1609.52 32 13.13 2622 1102 3.25 / 229.10 2 2
4 13 711.48 32 13.75 1366 601 3.85 / 229.70 2 3
5 13 21.36 32 14.37 386 177 4.03 / 229.88 2 5
6 8 0.20 175 14.13 338 836 4.87 / 230.72 2 16
Average= 4.61 (KJ/cycle)

Cycle 48 GMT 11/ 8/2016 19:18: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 27 14.39 507 197 0.20 / 221.16 2 2
2 7 2005.92 50 12.41 3159 1960 2.16 / 223.13 2 2
3 13 1615.48 32 13.12 2631 1105 3.26 / 224.23 2 2
4 13 731.84 32 13.75 1397 615 3.88 / 224.84 2 4
5 13 10.12 32 14.38 369 170 4.05 / 225.01 2 5
6 8 -0.04 175 14.13 338 836 4.88 / 225.85 2 18
Average= 4.61 (KJ/cycle)

Cycle 47 GMT 1/ 8/2016 19:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 27 14.45 486 190 0.19 / 216.32 2 2
2 3 973.60 -1 14.45 486 0 0.00 / 216.32 2 2
3 3 1031.20 1 13.79 1823 25 0.21 / 216.34 2 2
4 7 2001.16 50 12.43 3126 1943 2.16 / 218.28 2 2
5 13 1585.16 32 13.13 2581 1084 3.24 / 219.37 2 3
6 13 697.56 32 13.79 1328 586 3.83 / 219.95 2 3
7 13 22.92 32 14.38 388 179 4.01 / 220.13 2 5
8 8 0.04 175 14.15 337 834 4.84 / 220.97 2 15
Average= 4.60 (KJ/cycle)

Cycle 46 GMT 22/ 7/2016 19:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 27 14.42 493 192 0.19 / 211.46 2 2
2 7 2008.60 51 12.46 3144 1998 2.19 / 213.46 2 2
3 13 1604.88 32 13.14 2578 1084 3.27 / 214.55 2 2
4 13 717.08 32 13.76 1364 601 3.87 / 215.15 2 4
5 13 9.72 32 14.42 363 168 4.04 / 215.31 2 4
6 8 0.12 175 14.16 328 813 4.85 / 216.13 2 13
Average= 4.60 (KJ/cycle)

Cycle 45 GMT 12/ 7/2016 19:48: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 27 14.43 506 197 0.20 / 206.76 2 2
2 7 2001.48 51 12.47 3149 2003 2.20 / 208.76 2 2
3 13 1592.12 32 13.16 2584 1088 3.29 / 209.85 2 2
4 13 705.04 32 13.79 1341 592 3.88 / 210.44 2 4
5 8 0.08 175 14.22 333 829 4.71 / 211.27 2 12
Average= 4.59 (KJ/cycle)

Cycle 44 GMT 2/ 7/2016 20: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 27 14.44 501 195 0.20 / 201.85 2 2
2 7 2006.84 51 12.49 3156 2010 2.21 / 203.86 2 2
3 13 1605.92 32 13.16 2610 1099 3.30 / 204.96 2 3
4 13 719.24 32 13.79 1374 606 3.91 / 205.57 2 4
5 13 9.20 32 14.43 362 167 4.08 / 205.73 2 4
6 8 0.28 175 14.16 335 830 4.91 / 206.56 2 14
Average= 4.59 (KJ/cycle)

Cycle 43 GMT 22/ 6/2016 20:19:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 27 14.46 501 196 0.20 / 197.22 2 2
2 7 2007.60 50 12.57 3139 1973 2.17 / 199.19 2 2
3 13 1591.12 31 13.20 2565 1050 3.22 / 200.24 2 3
4 13 715.00 31 13.81 1363 584 3.80 / 200.83 2 4
5 8 0.08 175 14.25 332 828 4.63 / 201.66 2 14
Average= 4.58 (KJ/cycle)

Cycle 42 GMT 12/ 6/2016 20:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 27 14.49 507 198 0.20 / 192.42 2 2
2 7 2005.92 51 12.59 3143 2018 2.22 / 194.44 2 2
3 13 1599.40 29 13.23 2588 993 3.21 / 195.43 2 2
4 13 733.56 29 13.81 1410 565 3.77 / 196.00 2 3
5 13 61.84 29 14.38 453 189 3.96 / 196.19 2 4
6 8 0.00 175 14.20 338 840 4.80 / 197.03 2 16
Average= 4.58 (KJ/cycle)

Cycle 41 GMT 2/ 6/2016 20:29: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 27 14.46 510 199 0.20 / 187.66 2 2
2 7 2008.92 50 12.63 3145 1986 2.19 / 189.65 2 2
3 13 1597.12 29 13.26 2588 995 3.18 / 190.64 2 2
4 13 724.60 29 13.83 1381 554 3.73 / 191.19 2 3
5 13 62.40 29 14.39 447 187 3.92 / 191.38 2 5
6 8 0.20 175 14.19 339 842 4.76 / 192.22 2 15
Average= 4.58 (KJ/cycle)

Cycle 40 GMT 23/ 5/2016 20:29: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 27 14.47 495 193 0.19 / 182.83 2 2
2 7 2004.56 51 12.65 3168 2044 2.24 / 184.88 2 2
3 13 1594.44 29 13.25 2593 996 3.23 / 185.87 2 2
4 13 726.36 29 13.86 1376 553 3.79 / 186.42 2 3
5 13 57.84 29 14.41 442 185 3.97 / 186.61 2 4
6 8 0.80 175 14.18 343 851 4.82 / 187.46 2 20
Average= 4.57 (KJ/cycle)

Cycle 39 GMT 13/ 5/2016 20:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 27 14.51 501 196 0.20 / 178.01 2 2
2 7 2007.36 51 12.69 3160 2045 2.24 / 180.05 2 2
3 13 1591.60 29 13.29 2579 994 3.24 / 181.05 2 3
4 13 727.56 29 13.86 1390 559 3.79 / 181.61 2 3
5 13 59.68 29 14.42 447 187 3.98 / 181.79 2 4
6 8 0.24 175 14.20 340 845 4.83 / 182.64 2 16
Average= 4.57 (KJ/cycle)

Cycle 38 GMT 3/ 5/2016 20:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 27 14.51 491 192 0.19 / 173.26 2 2
2 7 2005.80 51 12.75 3145 2045 2.24 / 175.30 2 2
3 13 1421.40 29 13.42 2341 911 3.15 / 176.21 2 3
4 13 764.44 29 13.85 1438 578 3.73 / 176.79 2 4
5 13 56.28 29 14.43 440 184 3.91 / 176.98 2 4
6 8 -0.16 175 14.21 336 836 4.75 / 177.81 2 16
Average= 4.56 (KJ/cycle)

Cycle 37 GMT 23/ 4/2016 20:57: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 27 14.54 486 191 0.19 / 168.46 2 2
2 7 2010.12 51 12.79 3134 2044 2.24 / 170.51 2 2
3 13 1581.12 29 13.33 2568 993 3.23 / 171.50 2 2
4 13 715.88 29 13.91 1361 549 3.78 / 172.05 2 4
5 13 54.36 29 14.44 435 182 3.96 / 172.23 2 4
6 8 0.60 175 14.22 335 834 4.79 / 173.07 2 15
Average= 4.55 (KJ/cycle)

Cycle 36 GMT 13/ 4/2016 21:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 27 14.51 503 197 0.20 / 163.75 2 2
2 7 2001.52 50 12.80 3142 2011 2.21 / 165.76 2 2
3 13 1412.12 29 13.44 2327 907 3.11 / 166.67 2 3
4 13 758.24 29 13.88 1431 576 3.69 / 167.24 2 4
5 13 53.12 29 14.45 439 184 3.87 / 167.43 2 5
6 8 -0.20 175 14.22 340 846 4.72 / 168.27 2 17
Average= 4.55 (KJ/cycle)

Cycle 35 GMT 3/ 4/2016 21:19: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 27 14.54 491 193 0.19 / 158.92 2 2
2 7 2002.00 51 12.81 3151 2059 2.25 / 160.98 2 2
3 13 1583.72 29 13.34 2573 995 3.25 / 161.97 2 3
4 13 703.16 29 13.94 1343 543 3.79 / 162.52 2 3
5 13 52.20 29 14.45 443 186 3.98 / 162.70 2 5
6 8 0.12 175 14.23 341 849 4.82 / 163.55 2 18
Average= 4.54 (KJ/cycle)

Cycle 34 GMT 24/ 3/2016 21:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 27 14.55 487 191 0.19 / 154.15 2 2
2 7 2001.68 50 12.82 3124 2002 2.19 / 156.15 2 2
3 13 1589.76 29 13.36 2567 995 3.19 / 157.15 2 2
4 13 699.32 29 13.94 1351 546 3.73 / 157.69 2 3
5 13 46.52 29 14.47 428 180 3.91 / 157.87 2 5
6 8 0.16 175 14.23 344 857 4.77 / 158.73 2 17
Average= 4.54 (KJ/cycle)

Cycle 33 GMT 14/ 3/2016 21:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 27 14.54 494 194 0.19 / 149.46 2 2
2 7 2002.88 50 12.82 3161 2026 2.22 / 151.49 2 2
3 13 1410.88 29 13.47 2291 895 3.12 / 152.38 2 3
4 13 754.52 29 13.90 1429 576 3.69 / 152.96 2 4
5 13 28.32 29 14.50 399 168 3.86 / 153.12 2 5
6 8 0.08 175 14.25 334 833 4.69 / 153.96 2 17
Average= 4.53 (KJ/cycle)

Cycle 32 GMT 4/ 3/2016 22: 2: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 27 14.53 502 197 0.20 / 144.69 2 2
2 7 2007.84 51 12.82 3154 2062 2.26 / 146.75 2 2
3 13 1410.44 29 13.46 2323 907 3.17 / 147.66 2 2
4 13 755.80 29 13.90 1439 580 3.75 / 148.24 2 4
5 13 57.68 29 14.48 443 186 3.93 / 148.42 2 4
6 8 0.24 175 14.24 338 842 4.77 / 149.27 2 16
Average= 4.52 (KJ/cycle)

Cycle 31 GMT 23/ 2/2016 22: 9: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 27 14.56 490 193 0.19 / 139.94 2 2
2 7 2007.96 50 12.83 3165 2030 2.22 / 141.97 2 2
3 13 1425.28 29 13.46 2345 915 3.14 / 142.88 2 2
4 13 774.68 29 13.89 1469 592 3.73 / 143.48 2 4
5 13 29.32 29 14.52 403 170 3.90 / 143.65 2 5
6 8 0.16 175 14.25 339 845 4.75 / 144.49 2 16
Average= 4.52 (KJ/cycle)

Cycle 30 GMT 13/ 2/2016 22: 9: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 27 14.53 508 199 0.20 / 135.09 2 2
2 7 2001.32 51 12.84 3159 2069 2.27 / 137.16 2 2
3 13 1593.08 29 13.37 2580 1000 3.27 / 138.16 2 2
4 13 705.96 29 13.96 1345 545 3.81 / 138.70 2 4
5 13 44.96 29 14.50 427 180 3.99 / 138.88 2 5
6 8 -0.04 175 14.24 346 862 4.85 / 139.75 2 18
Average= 4.51 (KJ/cycle)

Cycle 29 GMT 3/ 2/2016 22:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 27 14.53 515 202 0.20 / 130.22 2 2
2 7 2003.72 50 12.85 3158 2029 2.23 / 132.25 2 2
3 13 1583.36 29 13.37 2576 999 3.23 / 133.25 2 2
4 13 700.96 29 13.96 1362 551 3.78 / 133.80 2 4
5 13 50.76 29 14.50 449 189 3.97 / 133.99 2 5
6 8 0.24 175 14.24 361 900 4.87 / 134.89 2 13
Average= 4.50 (KJ/cycle)

Cycle 28 GMT 24/ 1/2016 22:29: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 26 14.55 498 188 0.19 / 125.37 2 2
2 7 2009.08 50 12.86 3166 2036 2.22 / 127.40 2 2
3 13 1587.04 29 13.37 2582 1001 3.23 / 128.41 2 2
4 13 704.84 29 13.97 1355 549 3.77 / 128.95 2 4
5 13 46.44 29 14.50 441 185 3.96 / 129.14 2 5
6 8 0.24 175 14.24 354 882 4.84 / 130.02 2 15
Average= 4.48 (KJ/cycle)

Cycle 27 GMT 14/ 1/2016 22:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 26 14.54 499 189 0.19 / 120.56 2 2
2 7 2004.76 50 12.87 3166 2037 2.23 / 122.60 2 2
3 13 1582.16 29 13.38 2573 998 3.22 / 123.60 2 2
4 13 705.76 29 13.97 1349 547 3.77 / 124.15 2 4
5 13 49.28 29 14.50 437 184 3.95 / 124.33 2 5
6 8 -0.20 175 14.26 341 851 4.81 / 125.18 2 15
Average= 4.47 (KJ/cycle)

Cycle 26 GMT 4/ 1/2016 22:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 26 14.57 491 186 0.19 / 115.74 2 2
2 7 2005.52 50 12.90 3139 2025 2.21 / 117.77 2 2
3 13 1582.28 29 13.38 2579 1001 3.21 / 118.77 2 2
4 13 700.24 29 13.97 1362 552 3.76 / 119.32 2 4
5 13 43.44 29 14.52 427 180 3.94 / 119.50 2 5
6 8 0.40 175 14.25 350 873 4.82 / 120.37 2 13
Average= 4.46 (KJ/cycle)

Cycle 25 GMT 25/12/2015 23: 1: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 26 14.55 498 188 0.19 / 110.95 2 2
2 7 2006.52 50 12.91 3170 2046 2.23 / 112.99 2 2
3 13 1582.28 29 13.40 2551 991 3.23 / 113.98 2 2
4 13 698.28 29 13.98 1347 546 3.77 / 114.53 2 4
5 13 24.16 29 14.54 401 169 3.94 / 114.70 2 5
6 8 -0.04 175 14.25 345 860 4.80 / 115.56 2 19
Average= 4.44 (KJ/cycle)

Cycle 24 GMT 15/12/2015 23: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 26 14.54 504 191 0.19 / 106.16 2 2
2 7 2004.20 50 12.96 3138 2033 2.22 / 108.20 2 2
3 13 1576.12 29 13.39 2584 1003 3.23 / 109.20 2 2
4 13 684.88 29 14.01 1321 537 3.76 / 109.74 2 3
5 13 23.20 29 14.55 398 168 3.93 / 109.91 2 5
6 8 0.20 175 14.27 341 852 4.78 / 110.76 2 21
Average= 4.43 (KJ/cycle)

Cycle 23 GMT 5/12/2015 23:18: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 26 14.55 495 187 0.19 / 101.29 2 2
2 7 2003.28 51 12.98 3154 2088 2.28 / 103.37 2 2
3 13 1595.04 29 13.39 2583 1003 3.28 / 104.38 2 2
4 13 708.96 29 13.98 1369 555 3.83 / 104.93 2 4
5 13 23.76 29 14.55 405 171 4.00 / 105.10 2 5
6 8 0.00 175 14.26 349 871 4.87 / 105.97 2 19
Average= 4.42 (KJ/cycle)

Cycle 22 GMT 25/11/2015 23:22: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 26 14.56 516 195 0.20 / 96.68 2 2
2 7 2005.52 50 12.99 3157 2050 2.25 / 98.73 2 2
3 13 1408.32 25 13.57 2336 792 3.04 / 99.52 2 2
4 13 781.64 25 13.99 1479 517 3.56 / 100.04 2 3
5 13 71.48 25 14.52 478 174 3.73 / 100.21 2 4
6 8 0.20 175 14.27 355 887 4.62 / 101.10 2 15
Average= 4.40 (KJ/cycle)

Cycle 21 GMT 15/11/2015 23:16: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 26 14.54 522 197 0.20 / 92.11 2 2
2 7 2004.12 50 13.02 3126 2035 2.23 / 94.14 2 2
3 13 1394.16 25 13.60 2283 776 3.01 / 94.92 2 2
4 13 776.44 25 14.00 1458 510 3.52 / 95.43 2 4
5 13 79.04 25 14.53 483 175 3.69 / 95.61 2 4
6 8 -0.24 175 14.29 351 878 4.57 / 96.48 2 14
Average= 4.39 (KJ/cycle)

Cycle 20 GMT 5/11/2015 23: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 26 14.54 541 205 0.20 / 87.42 2 2
2 7 2008.16 51 13.02 3169 2104 2.31 / 89.52 2 2
3 13 1407.20 25 13.60 2341 796 3.10 / 90.32 2 2
4 13 780.28 25 14.00 1469 514 3.62 / 90.83 2 4
5 13 79.16 25 14.53 489 178 3.80 / 91.01 2 4
6 8 0.36 175 14.28 360 900 4.70 / 91.91 2 16
Average= 4.38 (KJ/cycle)

Cycle 19 GMT 26/10/2015 23: 6: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 26 14.57 512 194 0.19 / 82.75 2 2
2 7 2002.56 51 13.04 3162 2103 2.30 / 84.85 2 2
3 13 1385.12 25 13.60 2302 783 3.08 / 85.63 2 2
4 13 765.60 25 14.02 1448 508 3.59 / 86.14 2 4
5 13 76.60 25 14.54 484 176 3.76 / 86.32 2 4
6 8 -0.12 175 14.28 359 897 4.66 / 87.21 2 19
Average= 4.36 (KJ/cycle)

Cycle 18 GMT 16/10/2015 22:58: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 26 14.57 539 204 0.20 / 78.08 2 2
2 7 2005.72 51 13.05 3154 2099 2.30 / 80.18 2 2
3 13 1390.64 25 13.61 2316 788 3.09 / 80.97 2 2
4 13 749.76 25 14.02 1430 501 3.59 / 81.47 2 3
5 13 72.40 25 14.55 480 175 3.77 / 81.64 2 4
6 8 0.24 175 14.27 366 914 4.68 / 82.55 2 20
Average= 4.34 (KJ/cycle)

Cycle 17 GMT 6/10/2015 23: 1: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 26 14.54 519 196 0.20 / 73.42 2 2
2 7 2002.60 50 13.06 3128 2043 2.24 / 75.46 2 2
3 13 1396.12 25 13.62 2310 787 3.03 / 76.25 2 2
4 13 769.52 25 14.01 1486 520 3.55 / 76.77 2 3
5 13 75.68 25 14.54 495 180 3.73 / 76.95 2 4
6 8 0.28 175 14.27 371 926 4.65 / 77.87 2 21
Average= 4.33 (KJ/cycle)

Cycle 16 GMT 26/ 9/2015 22:48:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 26 14.58 530 201 0.20 / 68.69 2 2
2 7 2006.88 50 13.07 3142 2053 2.25 / 70.74 2 2
3 13 1403.64 25 13.60 2326 791 3.05 / 71.53 2 2
4 13 772.60 25 14.01 1466 513 3.56 / 72.05 2 3
5 13 149.40 25 14.49 587 213 3.77 / 72.26 2 4
6 8 -0.04 190 14.28 354 960 4.73 / 73.22 2 17
Average= 4.31 (KJ/cycle)

Cycle 15 GMT 16/ 9/2015 22:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 26 14.55 535 202 0.20 / 63.97 2 2
2 7 2004.20 50 13.09 3117 2040 2.24 / 66.01 2 2
3 13 1411.88 25 13.60 2365 804 3.05 / 66.81 2 2
4 13 777.60 25 14.01 1489 522 3.57 / 67.33 2 3
5 13 68.56 25 14.57 478 174 3.74 / 67.51 2 4
6 8 0.32 190 14.26 363 984 4.73 / 68.49 2 17
Average= 4.28 (KJ/cycle)

Cycle 14 GMT 6/ 9/2015 22:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 26 14.58 523 198 0.20 / 59.05 2 2
2 7 2001.12 51 13.08 3118 2080 2.28 / 61.13 2 2
3 13 1397.44 25 13.60 2311 786 3.06 / 61.91 2 2
4 13 756.04 25 14.01 1462 512 3.58 / 62.43 2 3
5 13 146.08 25 14.49 588 213 3.79 / 62.64 2 4
6 13 4.36 25 14.61 389 142 3.93 / 62.78 2 4
7 8 0.36 190 14.21 364 983 4.91 / 63.76 2 19
Average= 4.25 (KJ/cycle)

Cycle 13 GMT 27/ 8/2015 22:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 26 14.58 509 193 0.19 / 54.34 2 2
2 7 2001.20 51 13.08 3133 2090 2.28 / 56.43 2 2
3 13 1388.24 25 13.60 2308 785 3.07 / 57.22 2 2
4 13 753.28 25 14.02 1445 506 3.57 / 57.72 2 4
5 13 76.20 25 14.57 478 174 3.75 / 57.90 2 4
6 8 -0.44 190 14.27 352 954 4.70 / 58.85 2 17
Average= 4.20 (KJ/cycle)

Cycle 12 GMT 17/ 8/2015 22:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 26 14.57 522 198 0.20 / 49.58 2 2
2 3 971.92 -1 14.57 522 0 0.00 / 49.58 2 2
3 3 1035.56 1 14.60 1879 27 0.23 / 49.61 2 2
4 7 2006.80 50 13.08 3116 2038 2.26 / 51.65 2 2
5 13 1406.20 25 13.59 2336 794 3.06 / 52.44 2 2
6 13 757.28 25 14.01 1457 510 3.57 / 52.95 2 3
7 13 140.92 25 14.50 585 212 3.78 / 53.17 2 4
8 8 0.16 190 14.27 362 981 4.76 / 54.15 2 16
Average= 4.17 (KJ/cycle)

Cycle 11 GMT 7/ 8/2015 22:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 25 14.60 537 196 0.20 / 44.87 2 2
2 3 1038.08 1 14.58 1889 28 0.22 / 44.90 2 2
3 7 2001.76 50 13.06 3135 2047 2.27 / 46.94 2 2
4 13 1382.28 25 13.59 2305 783 3.05 / 47.73 2 2
5 13 745.72 25 14.01 1439 504 3.56 / 48.23 2 3
6 13 67.08 25 14.58 474 173 3.73 / 48.40 2 4
7 8 0.24 190 14.26 363 984 4.71 / 49.39 2 20
Average= 4.12 (KJ/cycle)

Cycle 10 GMT 28/ 7/2015 22: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 25 14.60 523 191 0.19 / 40.18 2 2
2 7 2004.24 50 13.06 3142 2052 2.24 / 42.23 2 2
3 13 1395.96 25 13.57 2315 785 3.03 / 43.01 2 2
4 13 760.00 25 14.00 1443 505 3.53 / 43.52 2 3
5 13 74.92 25 14.57 488 178 3.71 / 43.69 2 4
6 8 -0.24 190 14.26 361 978 4.69 / 44.67 2 21
Average= 4.06 (KJ/cycle)

Cycle 9 GMT 18/ 7/2015 21:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 25 14.57 522 190 0.19 / 35.49 2 2
2 7 2002.56 50 13.06 3114 2033 2.22 / 37.53 2 2
3 13 1391.56 25 13.57 2313 785 3.01 / 38.31 2 2
4 13 747.08 25 13.98 1443 504 3.51 / 38.81 2 3
5 13 73.60 25 14.57 493 180 3.69 / 38.99 2 4
6 8 0.28 190 14.24 366 990 4.68 / 39.98 2 21
Average= 4.00 (KJ/cycle)

Cycle 8 GMT 8/ 7/2015 21:36: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 24 14.56 532 186 0.19 / 30.86 2 2
2 7 2002.04 50 13.05 3100 2023 2.21 / 32.88 2 2
3 13 1380.60 25 13.55 2297 778 2.99 / 33.66 2 2
4 13 747.60 25 13.99 1411 493 3.48 / 34.15 2 3
5 13 65.48 25 14.59 471 172 3.65 / 34.32 2 4
6 8 0.08 190 14.25 361 977 4.63 / 35.30 2 16
Average= 3.92 (KJ/cycle)

Cycle 7 GMT 28/ 6/2015 21:23: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 24 14.58 516 181 0.18 / 26.21 2 2
2 7 2001.36 50 13.03 3115 2029 2.21 / 28.24 2 2
3 13 1379.48 25 13.54 2281 772 2.98 / 29.01 2 2
4 13 743.08 25 13.98 1418 496 3.48 / 29.51 2 3
5 13 70.96 25 14.57 484 176 3.65 / 29.68 2 4
6 8 0.40 190 14.21 366 988 4.64 / 30.67 2 17
Average= 3.83 (KJ/cycle)

Cycle 6 GMT 18/ 6/2015 21:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 23 14.54 531 178 0.18 / 21.42 2 2
2 3 1020.60 1 14.49 1857 27 0.20 / 21.45 2 2
3 7 2002.24 50 12.99 3124 2029 2.23 / 23.48 2 2
4 13 1563.56 25 13.42 2542 853 3.09 / 24.33 2 2
5 13 881.00 25 13.86 1605 556 3.64 / 24.89 2 3
6 13 86.24 25 14.55 492 179 3.82 / 25.07 2 4
7 8 -0.16 190 14.22 356 962 4.78 / 26.03 2 16
Average= 3.72 (KJ/cycle)

Cycle 5 GMT 8/ 6/2015 21:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 24 14.56 515 180 0.18 / 16.69 2 2
2 3 950.04 -1 14.56 515 0 0.00 / 16.69 2 2
3 7 2005.16 50 12.94 3116 2016 2.20 / 18.70 2 2
4 13 1576.76 25 13.35 2557 853 3.05 / 19.56 2 2
5 13 887.44 25 13.81 1629 562 3.61 / 20.12 2 3
6 13 50.20 25 14.56 452 165 3.78 / 20.28 2 4
7 8 0.16 190 14.17 358 964 4.74 / 21.25 2 15
Average= 3.54 (KJ/cycle)

Cycle 4 GMT 29/ 5/2015 21:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 24 14.54 514 179 0.18 / 12.86 2 2
2 7 1514.56 50 13.23 2472 1635 1.81 / 14.50 2 2
3 13 1137.24 25 13.59 1988 675 2.49 / 15.18 2 3
4 13 504.16 25 14.10 1069 377 2.87 / 15.55 2 3
5 8 0.32 190 14.23 353 954 3.82 / 16.51 2 17
Average= 3.30 (KJ/cycle)

Cycle 3 GMT 28/ 5/2015 21:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 24 14.51 505 176 0.18 / 8.68 2 2
2 3 964.88 -1 14.51 505 0 0.00 / 8.68 2 2
3 3 1030.64 1 14.40 1849 27 0.20 / 8.71 2 2
4 7 1514.76 51 13.14 2471 1656 1.86 / 10.37 2 2
5 13 1144.84 25 13.52 1971 666 2.52 / 11.03 2 3
6 13 506.48 25 14.05 1075 378 2.90 / 11.41 2 3
7 13 61.64 25 14.48 469 170 3.07 / 11.58 2 4
8 13 12.20 25 14.45 401 145 3.22 / 11.73 2 4
9 8 0.28 190 14.07 359 960 4.18 / 12.69 2 17
Average= 3.17 (KJ/cycle)

Cycle 2 GMT 27/ 5/2015 21:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 24 14.49 458 159 0.16 / 4.43 2 2
2 7 1515.28 75 12.84 2384 2296 2.46 / 6.72 2 2
3 13 802.44 20 13.81 1436 397 2.85 / 7.12 2 3
4 13 181.92 6 14.45 576 50 2.90 / 7.17 2 3
5 13 108.36 6 14.49 481 42 2.94 / 7.21 2 4
6 13 53.96 6 14.54 401 35 2.98 / 7.24 2 4
7 13 40.12 6 14.51 379 33 3.01 / 7.28 2 4
8 13 17.72 20 14.50 335 97 3.11 / 7.37 2 5
9 13 4.68 20 14.43 316 91 3.20 / 7.47 2 5
10 8 -0.16 240 14.11 308 1043 4.24 / 8.51 2 44
Average= 2.84 (KJ/cycle)

Cycle 1 GMT 26/ 5/2015 22:11: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 27 14.50 433 170 0.17 / 1.51 2 2
2 3 973.32 -1 14.50 433 0 0.00 / 1.51 2 2
3 3 1044.04 1 13.77 1828 25 0.19 / 1.53 2 2
4 7 1013.48 74 12.99 1722 1655 1.85 / 3.19 2 3
5 13 4.16 20 14.51 314 91 1.94 / 3.28 2 4
6 8 0.12 240 14.13 291 987 2.93 / 4.27 2 27
Average= 2.13 (KJ/cycle)

Cycle 0 GMT 26/ 5/2015 10:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 54.68 26 14.41 344 129 0.13 / 0.13 2 2
2 7 61.80 74 14.26 342 361 0.49 / 0.49 2 3
3 8 0.16 240 14.31 247 848 1.34 / 1.34 2 47
Average= 1.34 (KJ/cycle)