SIO Argo Site:
Pump Diagnostics Page   



Serial= 8376 WMO= 3901214

Return

←PreviousNext→

Cycle 330 GMT 19/ 5/2023 19:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 42 10.58 440 196 0.20 / 1610.29 3 3
2 12 1119.04 50 7.34 1895 695 0.89 / 1610.99 3 3
3 7 1126.08 21 7.36 1919 297 1.19 / 1611.28 3 3
4 13 1131.64 37 7.37 1912 521 1.71 / 1611.80 3 3
5 13 986.40 37 7.80 1721 497 2.21 / 1612.30 3 3
6 13 774.16 37 8.40 1430 444 2.65 / 1612.75 3 3
7 13 70.28 37 10.58 377 148 2.80 / 1612.89 3 3
8 8 0.12 190 10.82 276 567 3.37 / 1613.46 3 4
Average= 4.87 (KJ/cycle)

Cycle 329 GMT 10/ 5/2023 0:56: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 42 10.60 440 196 0.20 / 1606.89 3 3
2 12 1113.80 50 7.39 1894 700 0.90 / 1607.59 3 3
3 7 1121.04 21 7.46 1906 299 1.19 / 1607.89 3 3
4 13 1103.44 37 7.53 1893 527 1.72 / 1608.41 3 3
5 13 962.40 37 7.92 1693 496 2.22 / 1608.91 3 3
6 13 750.00 37 8.50 1407 443 2.66 / 1609.35 3 3
7 13 66.36 37 10.58 391 153 2.81 / 1609.51 3 3
8 8 -0.12 190 10.81 287 589 3.40 / 1610.10 3 6
Average= 4.88 (KJ/cycle)

Cycle 328 GMT 30/ 4/2023 5:55: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 42 10.62 437 195 0.19 / 1603.47 3 3
2 12 1116.44 50 7.48 1895 709 0.90 / 1604.18 3 3
3 7 1122.48 21 7.59 1906 304 1.21 / 1604.49 3 3
4 13 1086.80 37 7.64 1874 530 1.74 / 1605.02 3 3
5 13 922.56 37 8.09 1658 496 2.23 / 1605.51 3 3
6 13 713.64 37 8.64 1373 439 2.67 / 1605.95 3 3
7 13 51.92 37 10.62 374 147 2.82 / 1606.10 3 3
8 8 0.08 190 10.81 289 594 3.41 / 1606.69 3 4
Average= 4.88 (KJ/cycle)

Cycle 327 GMT 20/ 4/2023 11: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 42 10.59 445 198 0.20 / 1596.04 3 3
2 3 1014.04 1 8.17 1765 14 0.21 / 1596.05 3 3
3 12 1132.56 6 7.53 1925 87 0.30 / 1596.14 3 3
4 12 2010.24 50 5.15 3307 852 1.15 / 1596.99 3 3
5 7 2011.96 21 5.19 3365 367 1.52 / 1597.36 3 3
6 13 2020.84 37 5.20 3357 646 2.16 / 1598.00 3 3
7 13 2007.88 37 5.45 3235 652 2.82 / 1598.66 3 3
8 13 1941.04 37 5.81 3057 657 3.47 / 1599.31 3 3
9 13 1838.24 37 6.01 2919 649 4.12 / 1599.96 3 3
10 13 1698.12 37 6.40 2723 645 4.77 / 1600.61 3 3
11 13 1530.04 37 6.79 2488 625 5.39 / 1601.23 3 3
12 13 1336.76 37 7.17 2232 592 5.98 / 1601.82 3 3
13 13 928.28 37 8.19 1669 506 6.49 / 1602.33 3 3
14 13 455.16 37 9.41 1003 349 6.84 / 1602.68 3 3
15 8 0.04 190 10.83 292 601 7.44 / 1603.28 3 4
Average= 4.89 (KJ/cycle)

Cycle 326 GMT 19/ 4/2023 4:51: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 42 10.60 452 201 0.20 / 1592.82 3 3
2 12 1116.36 50 7.48 1895 709 0.91 / 1593.53 3 3
3 7 1122.96 21 7.57 1906 303 1.21 / 1593.83 3 3
4 13 1101.80 37 7.64 1903 538 1.75 / 1594.37 3 3
5 13 947.16 37 8.04 1692 503 2.25 / 1594.88 3 3
6 13 530.20 37 9.17 1102 374 2.63 / 1595.25 3 3
7 8 0.04 190 10.82 287 590 3.22 / 1595.84 3 3
Average= 4.88 (KJ/cycle)

Cycle 325 GMT 9/ 4/2023 9:52: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 42 10.63 441 197 0.20 / 1589.33 3 3
2 3 973.52 -1 10.63 441 0 0.00 / 1589.33 3 3
3 3 1050.76 2 8.08 1840 30 0.23 / 1589.36 3 3
4 12 1132.24 50 7.53 1918 722 0.95 / 1590.08 3 3
5 7 1138.24 21 7.59 1921 306 1.25 / 1590.39 3 3
6 13 1088.32 37 7.78 1871 539 1.79 / 1590.92 3 3
7 13 932.12 37 8.14 1675 504 2.30 / 1591.43 3 3
8 13 717.20 37 8.70 1373 442 2.74 / 1591.87 3 3
9 13 47.20 37 10.64 367 144 2.88 / 1592.02 3 3
10 8 0.00 190 10.81 295 606 3.49 / 1592.62 3 8
Average= 4.89 (KJ/cycle)

Cycle 324 GMT 30/ 3/2023 15: 6: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 42 10.69 438 197 0.20 / 1585.97 3 3
2 12 1122.08 50 7.65 1901 727 0.92 / 1586.70 3 3
3 7 1128.28 21 7.74 1914 311 1.23 / 1587.01 3 3
4 13 1079.48 37 7.87 1851 539 1.77 / 1587.55 3 3
5 13 918.68 37 8.29 1635 502 2.28 / 1588.05 3 3
6 13 500.96 37 9.34 1054 364 2.64 / 1588.41 3 3
7 13 25.96 37 10.74 326 130 2.77 / 1588.54 3 3
8 8 0.12 190 10.84 286 589 3.36 / 1589.13 3 9
Average= 4.89 (KJ/cycle)

Cycle 323 GMT 20/ 3/2023 20: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 43 10.62 435 199 0.20 / 1580.43 3 3
2 3 958.24 -1 10.62 435 0 0.00 / 1580.43 3 3
3 3 1028.52 1 8.31 1780 15 0.21 / 1580.45 3 3
4 12 1143.32 6 7.68 1957 90 0.30 / 1580.54 3 3
5 12 2002.60 50 5.60 3178 890 1.19 / 1581.43 3 3
6 7 2001.52 21 5.74 3161 381 1.57 / 1581.81 3 3
7 13 1879.00 37 6.12 2959 670 2.24 / 1582.48 3 3
8 13 1731.40 37 6.51 2765 666 2.91 / 1583.15 3 3
9 13 1568.32 37 6.83 2545 643 3.55 / 1583.79 3 3
10 13 1373.12 37 7.30 2278 615 4.17 / 1584.40 3 3
11 13 930.32 37 8.30 1671 513 4.68 / 1584.92 3 3
12 13 241.36 37 10.10 676 253 4.93 / 1585.17 3 3
13 8 0.12 190 10.86 292 603 5.54 / 1585.77 3 3
Average= 4.89 (KJ/cycle)

Cycle 322 GMT 19/ 3/2023 15:50: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 42 10.65 439 196 0.20 / 1577.06 3 3
2 12 1125.88 50 7.62 1908 727 0.92 / 1577.79 3 3
3 7 1130.64 21 7.72 1918 311 1.23 / 1578.10 3 3
4 13 1072.96 37 7.87 1847 538 1.77 / 1578.64 3 3
5 13 917.84 37 8.24 1645 502 2.27 / 1579.14 3 3
6 13 510.32 37 9.31 1067 368 2.64 / 1579.51 3 3
7 13 25.60 37 10.73 330 131 2.77 / 1579.64 3 3
8 8 0.12 190 10.83 290 597 3.37 / 1580.24 3 10
Average= 4.89 (KJ/cycle)

Cycle 321 GMT 9/ 3/2023 20:57: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 43 10.71 423 195 0.19 / 1573.69 3 3
2 3 953.80 -1 10.71 423 0 0.00 / 1573.69 3 3
3 3 1028.00 1 8.31 1805 15 0.21 / 1573.70 3 3
4 12 1129.84 50 7.64 1922 734 0.94 / 1574.44 3 3
5 7 1135.08 21 7.73 1929 313 1.26 / 1574.75 3 3
6 13 1081.04 37 7.92 1854 543 1.80 / 1575.29 3 3
7 13 916.36 37 8.33 1638 505 2.31 / 1575.80 3 3
8 13 486.04 37 9.41 1032 359 2.66 / 1576.16 3 3
9 13 21.88 37 10.78 319 127 2.79 / 1576.28 3 3
10 8 -0.12 190 10.86 283 584 3.38 / 1576.87 3 7
Average= 4.90 (KJ/cycle)

Cycle 320 GMT 28/ 2/2023 2: 3: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 42 10.74 426 192 0.19 / 1570.32 3 3
2 12 1112.96 50 7.77 1896 737 0.93 / 1571.05 3 3
3 7 1119.40 21 7.87 1902 314 1.24 / 1571.37 3 3
4 13 1061.04 37 8.02 1827 542 1.79 / 1571.91 3 3
5 13 893.64 37 8.41 1614 502 2.29 / 1572.41 3 3
6 13 468.88 37 9.50 1007 354 2.64 / 1572.77 3 3
7 13 40.76 37 10.72 348 138 2.78 / 1572.91 3 3
8 8 0.08 190 10.86 284 586 3.37 / 1573.49 3 7
Average= 4.90 (KJ/cycle)

Cycle 319 GMT 18/ 2/2023 7:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 43 10.68 439 202 0.20 / 1564.70 3 3
2 12 1101.16 6 7.83 1897 89 0.29 / 1564.79 3 3
3 12 2003.60 50 5.97 3143 938 1.23 / 1565.73 3 3
4 7 2002.44 21 6.06 3160 402 1.63 / 1566.13 3 3
5 13 1860.88 37 6.47 2929 701 2.33 / 1566.83 3 3
6 13 1731.36 37 6.75 2761 690 3.02 / 1567.52 3 3
7 13 1529.40 37 7.18 2491 662 3.68 / 1568.19 3 3
8 13 1314.32 37 7.63 2188 618 4.30 / 1568.80 3 3
9 13 889.08 37 8.55 1618 512 4.81 / 1569.32 3 3
10 13 200.56 37 10.33 596 228 5.04 / 1569.54 3 3
11 8 0.04 190 10.91 281 582 5.62 / 1570.13 3 5
Average= 4.91 (KJ/cycle)

Cycle 318 GMT 17/ 2/2023 2:51: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 42 10.70 430 193 0.19 / 1561.21 3 3
2 12 1146.60 50 7.70 1940 747 0.94 / 1561.96 3 3
3 7 1151.24 21 7.77 1953 319 1.26 / 1562.28 3 3
4 13 1098.48 37 7.92 1876 550 1.81 / 1562.83 3 3
5 13 941.40 37 8.31 1675 515 2.32 / 1563.34 3 3
6 13 723.80 37 8.87 1381 453 2.78 / 1563.80 3 3
7 13 24.40 37 10.80 320 128 2.90 / 1563.92 3 3
8 8 0.08 190 10.89 280 579 3.48 / 1564.50 3 7
Average= 4.90 (KJ/cycle)

Cycle 317 GMT 7/ 2/2023 8: 2: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 42 10.71 437 197 0.20 / 1557.83 3 3
2 12 1109.28 50 7.80 1891 737 0.93 / 1558.56 3 3
3 7 1114.92 21 7.89 1898 314 1.25 / 1558.88 3 3
4 13 1059.40 37 8.05 1835 547 1.80 / 1559.43 3 3
5 13 894.36 37 8.45 1617 506 2.30 / 1559.93 3 3
6 13 464.08 37 9.52 1009 355 2.66 / 1560.29 3 3
7 13 38.32 37 10.73 350 139 2.80 / 1560.43 3 3
8 8 0.04 190 10.87 287 593 3.39 / 1561.02 3 7
Average= 4.91 (KJ/cycle)

Cycle 316 GMT 28/ 1/2023 13:17: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 42 10.73 448 202 0.20 / 1554.42 3 3
2 12 1115.20 50 7.84 1900 745 0.95 / 1555.16 3 3
3 7 1121.72 21 7.93 1909 318 1.26 / 1555.48 3 3
4 13 1062.12 37 8.08 1849 553 1.82 / 1556.03 3 3
5 13 902.12 37 8.49 1628 511 2.33 / 1556.54 3 3
6 13 481.04 37 9.51 1031 363 2.69 / 1556.91 3 3
7 13 23.00 37 10.80 324 129 2.82 / 1557.04 3 3
8 8 -0.04 190 10.88 288 595 3.42 / 1557.63 3 5
Average= 4.91 (KJ/cycle)

Cycle 315 GMT 18/ 1/2023 18:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 44 10.71 435 205 0.20 / 1548.93 3 3
2 3 943.84 -1 10.71 435 0 0.00 / 1548.93 3 3
3 3 1018.04 1 8.38 1761 15 0.22 / 1548.94 3 3
4 12 1125.80 6 7.88 1911 90 0.31 / 1549.03 3 3
5 12 1999.04 50 6.04 3139 948 1.26 / 1549.98 3 3
6 7 1997.52 21 6.15 3142 406 1.66 / 1550.39 3 3
7 13 1873.44 37 6.49 2970 713 2.38 / 1551.10 3 3
8 13 1704.48 37 6.93 2739 702 3.08 / 1551.80 3 3
9 13 1521.32 37 7.33 2477 672 3.75 / 1552.47 3 3
10 13 1096.04 37 8.21 1902 578 4.33 / 1553.05 3 3
11 13 650.84 37 9.15 1282 434 4.76 / 1553.49 3 3
12 13 32.16 37 10.81 336 134 4.90 / 1553.62 3 3
13 8 0.12 190 10.90 287 594 5.49 / 1554.21 3 9
Average= 4.92 (KJ/cycle)

Cycle 314 GMT 17/ 1/2023 13:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 42 10.72 440 198 0.20 / 1545.43 3 3
2 12 1116.24 50 7.84 1894 742 0.94 / 1546.18 3 3
3 7 1122.44 21 7.88 1923 318 1.26 / 1546.49 3 3
4 13 1063.96 37 8.07 1857 554 1.81 / 1547.05 3 3
5 13 896.72 37 8.48 1625 510 2.32 / 1547.56 3 3
6 13 681.24 37 9.02 1322 441 2.76 / 1548.00 3 3
7 13 34.84 37 10.77 341 136 2.90 / 1548.13 3 3
8 8 -0.12 190 10.89 284 588 3.49 / 1548.72 3 4
Average= 4.92 (KJ/cycle)

Cycle 313 GMT 7/ 1/2023 18:42: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 42 10.71 442 199 0.20 / 1542.15 3 3
2 12 1120.68 50 7.86 1898 746 0.94 / 1542.89 3 3
3 7 1126.52 21 7.97 1908 319 1.26 / 1543.21 3 3
4 13 1072.96 37 8.12 1852 556 1.82 / 1543.77 3 3
5 13 906.28 37 8.53 1620 511 2.33 / 1544.28 3 3
6 13 470.48 37 9.58 1008 357 2.69 / 1544.64 3 3
7 8 0.28 190 10.89 289 598 3.29 / 1545.23 3 3
Average= 4.92 (KJ/cycle)

Cycle 312 GMT 29/12/2022 0: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 42 10.75 441 199 0.20 / 1538.83 3 3
2 12 1134.20 50 7.89 1921 758 0.96 / 1539.59 3 3
3 7 1140.16 21 8.02 1927 325 1.28 / 1539.92 3 3
4 13 1078.20 37 8.19 1851 561 1.84 / 1540.48 3 3
5 13 910.56 37 8.54 1639 518 2.36 / 1541.00 3 3
6 13 485.52 37 9.58 1031 365 2.73 / 1541.36 3 3
7 8 -0.16 190 10.91 283 587 3.31 / 1541.95 3 3
Average= 4.93 (KJ/cycle)

Cycle 311 GMT 19/12/2022 5: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 42 10.71 449 202 0.20 / 1533.30 3 3
2 3 1033.16 1 8.60 1790 15 0.22 / 1533.31 3 3
3 3 1015.92 1 8.54 1782 15 0.23 / 1533.33 3 3
4 12 1142.80 6 8.07 1925 93 0.33 / 1533.42 3 3
5 12 2002.80 50 6.28 3135 984 1.31 / 1534.40 3 3
6 7 2001.16 21 6.23 3169 415 1.72 / 1534.82 3 3
7 13 1855.24 37 6.58 2961 721 2.45 / 1535.54 3 3
8 13 1691.60 37 7.06 2710 708 3.15 / 1536.25 3 3
9 13 1488.44 37 7.48 2433 673 3.83 / 1536.92 3 3
10 13 1065.08 37 8.32 1861 573 4.40 / 1537.49 3 3
11 13 616.68 37 9.33 1229 424 4.82 / 1537.92 3 3
12 13 13.52 37 10.89 305 123 4.95 / 1538.04 3 3
13 8 0.04 190 10.93 286 594 5.54 / 1538.64 3 6
Average= 4.93 (KJ/cycle)

Cycle 310 GMT 18/12/2022 1:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 41 10.75 427 188 0.19 / 1529.99 3 3
2 12 1125.28 50 7.94 1912 759 0.95 / 1530.75 3 3
3 7 1131.36 21 7.98 1920 322 1.27 / 1531.07 3 3
4 13 1082.36 37 8.17 1859 562 1.83 / 1531.64 3 3
5 13 912.40 37 8.58 1631 518 2.35 / 1532.15 3 3
6 13 468.68 37 9.64 1005 358 2.71 / 1532.51 3 3
7 8 0.36 190 10.92 281 583 3.29 / 1533.09 3 5
Average= 4.93 (KJ/cycle)

Cycle 309 GMT 8/12/2022 6:42: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 43 10.75 432 200 0.20 / 1526.66 3 3
2 3 950.28 -1 10.75 432 0 0.00 / 1526.66 3 3
3 3 1034.96 1 8.53 1811 15 0.22 / 1526.68 3 3
4 12 1141.28 50 7.93 1936 768 0.98 / 1527.45 3 3
5 7 1147.28 21 8.04 1944 328 1.31 / 1527.78 3 3
6 13 1086.24 37 8.20 1866 566 1.88 / 1528.34 3 3
7 13 914.00 37 8.63 1616 516 2.39 / 1528.86 3 3
8 13 477.52 37 9.64 1016 362 2.76 / 1529.22 3 3
9 8 -0.04 190 10.93 281 584 3.34 / 1529.80 3 4
Average= 4.93 (KJ/cycle)

Cycle 308 GMT 28/11/2022 11:59: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 42 10.74 455 205 0.21 / 1523.29 3 3
2 3 1020.56 1 8.60 1790 15 0.22 / 1523.30 3 3
3 12 1141.88 50 7.96 1940 772 0.99 / 1524.08 3 3
4 7 1147.80 21 8.04 1959 331 1.32 / 1524.41 3 3
5 13 1082.04 37 8.25 1862 568 1.89 / 1524.97 3 3
6 13 917.60 37 8.62 1662 530 2.42 / 1525.50 3 3
7 13 480.48 37 9.64 1030 367 2.79 / 1525.87 3 3
8 8 0.16 190 10.92 286 593 3.38 / 1526.47 3 4
Average= 4.94 (KJ/cycle)

Cycle 307 GMT 18/11/2022 17:10: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 42 10.75 431 195 0.19 / 1517.65 3 3
2 3 966.44 -1 10.75 431 0 0.00 / 1517.65 3 3
3 3 1043.92 2 8.60 1832 32 0.23 / 1517.68 3 3
4 12 1129.12 6 8.08 1955 95 0.32 / 1517.77 3 3
5 12 2001.04 50 6.39 3142 1004 1.32 / 1518.78 3 3
6 7 1998.88 21 6.32 3151 418 1.74 / 1519.19 3 3
7 13 1847.80 37 6.83 2918 737 2.48 / 1519.93 3 3
8 13 1675.40 37 7.17 2693 714 3.19 / 1520.65 3 3
9 13 1473.24 37 7.52 2438 678 3.87 / 1521.32 3 3
10 13 1256.80 37 7.99 2131 630 4.50 / 1521.95 3 3
11 13 537.44 37 9.53 1118 394 4.90 / 1522.35 3 3
12 13 3.40 37 10.90 303 122 5.02 / 1522.47 3 3
13 8 0.20 190 10.91 295 612 5.63 / 1523.08 3 6
Average= 4.95 (KJ/cycle)

Cycle 306 GMT 17/11/2022 13: 7:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 42 10.71 439 197 0.20 / 1514.27 3 3
2 3 956.36 -1 10.71 439 0 0.00 / 1514.27 3 3
3 3 1036.64 1 8.64 1810 16 0.21 / 1514.28 3 3
4 12 1158.32 50 7.90 1964 776 0.99 / 1515.06 3 3
5 7 1164.60 21 7.98 1964 329 1.32 / 1515.39 3 3
6 13 1100.12 37 8.23 1885 574 1.89 / 1515.96 3 3
7 13 928.60 37 8.62 1650 526 2.42 / 1516.49 3 3
8 13 494.36 37 9.60 1045 371 2.79 / 1516.86 3 3
9 8 -0.16 190 10.90 286 592 3.38 / 1517.45 3 3
Average= 4.94 (KJ/cycle)

Cycle 305 GMT 7/11/2022 18:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 41 10.73 450 198 0.20 / 1510.95 3 3
2 12 1122.72 50 8.05 1917 772 0.97 / 1511.72 3 3
3 7 1130.80 21 8.08 1927 327 1.30 / 1512.05 3 3
4 13 1050.72 37 8.34 1819 561 1.86 / 1512.61 3 3
5 13 877.00 37 8.73 1589 513 2.37 / 1513.12 3 3
6 13 427.92 37 9.77 952 344 2.72 / 1513.47 3 3
7 8 0.44 190 10.90 290 601 3.32 / 1514.07 3 7
Average= 4.95 (KJ/cycle)

Cycle 304 GMT 28/10/2022 23:45: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 41 10.74 446 196 0.20 / 1507.59 3 3
2 3 1013.52 1 8.79 1776 16 0.21 / 1507.61 3 3
3 12 1122.44 50 8.12 1916 778 0.99 / 1508.38 3 3
4 7 1128.28 21 8.19 1922 331 1.32 / 1508.71 3 3
5 13 1063.56 37 8.37 1834 568 1.89 / 1509.28 3 3
6 13 900.96 37 8.75 1623 525 2.41 / 1509.81 3 3
7 13 449.76 37 9.76 981 354 2.77 / 1510.16 3 3
8 8 -0.28 190 10.93 285 592 3.36 / 1510.75 3 4
Average= 4.95 (KJ/cycle)

Cycle 303 GMT 19/10/2022 5: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 42 10.68 446 200 0.20 / 1501.97 3 3
2 12 1123.96 6 8.10 1932 94 0.29 / 1502.06 3 3
3 12 2002.08 50 6.04 3149 951 1.24 / 1503.01 3 3
4 7 2000.32 21 5.85 3152 387 1.63 / 1503.40 3 3
5 13 1885.80 37 6.47 2981 714 2.35 / 1504.11 3 3
6 13 1738.40 37 6.82 2795 705 3.05 / 1504.82 3 3
7 13 1560.36 37 7.26 2550 685 3.74 / 1505.50 3 3
8 13 1353.84 37 7.71 2252 642 4.38 / 1506.14 3 3
9 13 901.12 37 8.75 1618 524 4.90 / 1506.67 3 3
10 13 42.96 37 10.84 342 137 5.04 / 1506.81 3 3
11 8 0.12 190 10.93 283 588 5.63 / 1507.39 3 6
Average= 4.96 (KJ/cycle)

Cycle 302 GMT 18/10/2022 0:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 39 10.68 440 183 0.18 / 1498.61 3 3
2 3 1048.40 2 8.61 1822 31 0.21 / 1498.64 3 3
3 3 1031.48 1 8.71 1790 16 0.23 / 1498.65 3 3
4 12 1154.56 50 7.79 1952 760 0.99 / 1499.41 3 3
5 7 1160.20 21 7.78 1957 320 1.31 / 1499.73 3 3
6 13 1103.52 37 8.08 1881 562 1.87 / 1500.29 3 3
7 13 937.24 37 8.49 1653 519 2.39 / 1500.81 3 3
8 13 510.72 37 9.51 1061 373 2.77 / 1501.19 3 3
9 8 0.40 190 10.89 280 579 3.34 / 1501.77 3 3
Average= 4.96 (KJ/cycle)

Cycle 301 GMT 8/10/2022 6:10: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 41 10.78 432 191 0.19 / 1495.31 3 3
2 12 1127.04 50 7.90 1918 758 0.95 / 1496.06 3 3
3 7 1133.08 21 7.89 1923 319 1.27 / 1496.38 3 3
4 13 1081.52 37 8.15 1871 564 1.83 / 1496.95 3 3
5 13 912.56 37 8.58 1639 520 2.35 / 1497.47 3 3
6 13 488.92 37 9.61 1039 369 2.72 / 1497.84 3 3
7 8 -0.16 190 10.89 283 586 3.31 / 1498.42 3 3
Average= 4.96 (KJ/cycle)

Cycle 300 GMT 28/ 9/2022 11:18: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 36 10.96 448 177 0.18 / 1491.97 3 3
2 3 1096.88 4 9.17 1923 71 0.25 / 1492.04 3 3
3 3 1035.32 1 9.40 1839 17 0.26 / 1492.05 3 3
4 12 1137.36 50 8.31 1939 806 1.07 / 1492.86 3 3
5 7 1143.48 21 8.07 1948 330 1.40 / 1493.19 3 3
6 13 1061.64 37 8.40 1831 569 1.97 / 1493.76 3 3
7 13 883.84 37 8.86 1589 521 2.49 / 1494.28 3 3
8 13 220.16 37 10.39 629 242 2.73 / 1494.52 3 3
9 8 -0.04 190 10.92 286 593 3.33 / 1495.12 3 8
Average= 4.97 (KJ/cycle)

Cycle 299 GMT 18/ 9/2022 16:33: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 32 11.20 454 163 0.16 / 1486.62 3 3
2 10 1007.88 6 9.67 1808 105 0.27 / 1486.73 3 3
3 3 1081.60 3 9.54 1928 55 0.32 / 1486.78 3 3
4 3 1042.16 2 9.62 1842 35 0.36 / 1486.82 3 3
5 12 1136.80 6 9.41 1983 112 0.47 / 1486.93 3 3
6 12 1975.16 50 7.65 3140 1201 1.67 / 1488.13 3 3
7 7 1971.60 21 7.05 3128 463 2.13 / 1488.59 3 3
8 13 1784.72 37 7.66 2855 809 2.94 / 1489.40 3 3
9 13 1579.28 37 8.03 2593 770 3.71 / 1490.17 3 3
10 13 1126.36 37 8.80 1972 642 4.36 / 1490.82 3 3
11 13 433.24 37 10.12 957 358 4.71 / 1491.17 3 3
12 8 0.04 190 11.09 292 615 5.33 / 1491.79 3 3
Average= 4.97 (KJ/cycle)

Cycle 298 GMT 17/ 9/2022 11:59: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 33 11.69 449 173 0.17 / 1483.18 3 3
2 10 1008.44 6 10.38 1824 114 0.29 / 1483.29 3 3
3 12 1116.24 50 7.39 1888 698 0.98 / 1483.99 3 3
4 7 1122.68 21 7.75 1910 311 1.30 / 1484.30 3 3
5 13 1095.84 37 8.27 1882 576 1.87 / 1484.88 3 3
6 13 943.04 37 8.89 1681 553 2.42 / 1485.43 3 3
7 13 515.52 37 10.00 1094 405 2.83 / 1485.84 3 3
8 8 0.00 190 11.31 290 623 3.45 / 1486.46 3 3
Average= 4.97 (KJ/cycle)

Cycle 297 GMT 7/ 9/2022 17: 9: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 34 12.23 482 200 0.20 / 1479.76 3 3
2 3 1043.20 2 11.27 1885 42 0.24 / 1479.81 3 3
3 3 1016.68 1 11.07 1855 21 0.26 / 1479.83 3 3
4 12 1139.12 50 8.03 1938 778 1.04 / 1480.60 3 3
5 7 1145.08 21 8.70 1960 358 1.40 / 1480.96 3 3
6 13 1050.24 37 9.14 1860 629 2.03 / 1481.59 3 3
7 13 866.80 37 9.70 1608 577 2.61 / 1482.17 3 3
8 13 79.52 37 11.72 421 183 2.79 / 1482.35 3 3
9 8 0.20 190 11.76 294 657 3.45 / 1483.01 3 9
Average= 4.98 (KJ/cycle)

Cycle 296 GMT 28/ 8/2022 22:32: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 33 12.76 469 197 0.20 / 1476.15 3 3
2 3 1026.80 1 11.90 1818 22 0.22 / 1476.17 3 3
3 12 1160.24 50 8.64 1988 859 1.08 / 1477.03 3 3
4 7 1165.60 21 9.27 2011 391 1.47 / 1477.42 3 3
5 13 1054.76 37 9.91 1860 682 2.15 / 1478.10 3 3
6 13 844.56 37 10.39 1561 600 2.75 / 1478.70 3 3
7 13 32.04 37 12.40 351 161 2.91 / 1478.86 3 3
8 8 0.12 190 12.25 301 701 3.61 / 1479.56 3 10
Average= 4.98 (KJ/cycle)

Cycle 295 GMT 19/ 8/2022 3:59: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 32 13.17 467 197 0.20 / 1470.99 3 3
2 12 1127.16 6 11.78 2040 144 0.34 / 1471.13 3 3
3 12 1943.48 50 9.79 3163 1548 1.89 / 1472.68 3 3
4 7 1939.08 21 9.48 3155 628 2.52 / 1473.31 3 3
5 13 1501.56 37 10.28 2551 970 3.49 / 1474.28 3 3
6 13 780.84 37 11.40 1495 631 4.12 / 1474.91 3 3
7 13 130.24 37 12.65 538 252 4.37 / 1475.16 3 3
8 8 0.16 190 12.65 327 786 5.16 / 1475.95 3 10
Average= 4.99 (KJ/cycle)

Cycle 294 GMT 17/ 8/2022 23:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 29 13.62 475 188 0.19 / 1467.13 3 3
2 10 1010.44 4 12.55 1853 93 0.28 / 1467.22 3 3
3 12 1080.80 50 6.58 1800 592 0.87 / 1467.82 3 3
4 7 1087.44 21 9.40 1897 374 1.25 / 1468.19 3 3
5 13 1113.72 37 9.59 1957 694 1.94 / 1468.89 3 3
6 13 943.88 37 10.44 1717 663 2.60 / 1469.55 3 3
7 13 460.68 37 12.07 1004 448 3.05 / 1470.00 3 3
8 8 -0.12 190 13.01 322 796 3.85 / 1470.79 3 9
Average= 4.99 (KJ/cycle)

Cycle 293 GMT 8/ 8/2022 5:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 31 13.74 502 214 0.21 / 1463.24 3 3
2 10 1007.44 5 12.75 1813 116 0.33 / 1463.35 3 3
3 3 881.04 -2 12.75 1813 0 0.12 / 1463.35 3 3
4 12 1169.80 50 6.64 1923 638 0.97 / 1463.99 3 3
5 7 1177.08 21 9.46 2039 405 1.37 / 1464.39 3 3
6 13 1174.96 37 10.10 2067 772 2.15 / 1465.17 3 3
7 13 985.24 37 10.90 1789 722 2.87 / 1465.89 3 3
8 13 130.52 37 13.46 516 257 3.12 / 1466.15 3 3
9 8 0.28 190 13.48 312 799 3.92 / 1466.94 3 11
Average= 4.99 (KJ/cycle)

Cycle 292 GMT 29/ 7/2022 10:27: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 31 13.92 507 219 0.22 / 1459.49 3 3
2 3 1013.88 1 11.84 1874 22 0.24 / 1459.51 3 3
3 12 1128.84 50 7.96 1918 763 1.00 / 1460.28 3 3
4 7 1134.84 21 10.00 1979 416 1.42 / 1460.69 3 3
5 13 1023.76 37 11.28 1857 775 2.19 / 1461.47 3 3
6 13 813.92 37 12.04 1515 675 2.87 / 1462.14 3 3
7 8 -0.08 190 13.56 341 879 3.75 / 1463.02 3 14
Average= 4.99 (KJ/cycle)

Cycle 291 GMT 19/ 7/2022 16:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 31 13.84 515 221 0.22 / 1454.27 3 3
2 3 1013.96 1 11.17 1849 21 0.24 / 1454.29 3 3
3 12 1121.40 6 11.44 2005 138 0.38 / 1454.42 3 3
4 12 1960.56 50 9.49 3173 1506 1.88 / 1455.93 3 3
5 7 1954.60 21 9.69 3173 646 2.53 / 1456.57 3 3
6 13 1521.80 37 11.41 2581 1090 3.62 / 1457.66 3 3
7 13 808.32 37 12.74 1505 709 4.33 / 1458.37 3 3
8 8 0.20 190 13.72 345 899 5.23 / 1459.27 3 15
Average= 5.00 (KJ/cycle)

Cycle 290 GMT 18/ 7/2022 11:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 31 13.95 497 215 0.21 / 1451.29 3 3
2 3 969.76 -1 13.95 497 0 0.00 / 1451.29 3 3
3 7 1100.76 20 6.82 1835 250 0.47 / 1451.54 3 3
4 13 995.84 37 11.38 1808 761 1.23 / 1452.30 3 3
5 13 786.40 37 12.00 1496 664 1.89 / 1452.97 3 3
6 13 1.00 37 13.99 362 187 2.08 / 1453.15 3 3
7 8 0.12 190 13.48 348 891 2.97 / 1454.04 3 12
Average= 5.00 (KJ/cycle)

Cycle 289 GMT 10/ 7/2022 20:29: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 31 14.09 511 223 0.22 / 1447.66 3 3
2 12 1101.12 50 6.94 1836 637 0.86 / 1448.30 3 3
3 7 1107.80 21 10.06 1949 412 1.27 / 1448.71 3 3
4 13 1029.68 37 11.21 1847 766 2.04 / 1449.48 3 3
5 13 834.96 37 12.10 1547 693 2.73 / 1450.17 3 3
6 8 -0.12 190 13.78 346 906 3.64 / 1451.07 3 11
Average= 5.00 (KJ/cycle)

Cycle 288 GMT 1/ 7/2022 2: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 30 14.12 506 214 0.21 / 1443.99 3 3
2 3 1016.96 1 12.00 1874 22 0.24 / 1444.01 3 3
3 12 1124.96 50 8.53 1930 823 1.06 / 1444.83 3 3
4 7 1130.84 21 10.30 1979 428 1.49 / 1445.26 3 3
5 13 1009.80 37 11.89 1807 795 2.28 / 1446.06 3 3
6 13 399.36 37 13.43 926 460 2.74 / 1446.52 3 3
7 8 0.24 190 13.88 349 920 3.66 / 1447.44 3 15
Average= 5.01 (KJ/cycle)

Cycle 287 GMT 21/ 6/2022 7:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 31 14.07 502 219 0.22 / 1438.82 3 3
2 12 1120.88 6 11.44 1994 137 0.36 / 1438.96 3 3
3 12 1946.88 50 9.90 3157 1563 1.92 / 1440.52 3 3
4 7 1941.36 21 10.06 3167 669 2.59 / 1441.19 3 3
5 13 1469.12 37 11.95 2526 1117 3.70 / 1442.31 3 3
6 13 496.88 37 13.45 1070 532 4.24 / 1442.84 3 3
7 8 0.24 190 13.93 354 937 5.17 / 1443.77 3 11
Average= 5.01 (KJ/cycle)

Cycle 286 GMT 20/ 6/2022 3: 6: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 31 14.11 496 217 0.22 / 1434.77 3 3
2 12 1110.16 50 5.84 1771 517 0.73 / 1435.29 3 3
3 7 1118.16 21 9.93 1960 409 1.14 / 1435.70 3 3
4 13 1169.80 37 10.80 2070 827 1.97 / 1436.53 3 3
5 13 990.08 37 11.66 1815 783 2.75 / 1437.31 3 3
6 13 264.56 37 13.60 741 373 3.13 / 1437.68 3 3
7 8 0.12 190 13.93 347 918 4.04 / 1438.60 3 15
Average= 5.01 (KJ/cycle)

Cycle 285 GMT 10/ 6/2022 8:18: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 31 14.16 490 215 0.22 / 1430.79 3 3
2 3 972.56 -1 14.16 490 0 0.00 / 1430.79 3 3
3 3 1030.68 1 11.67 1862 22 0.24 / 1430.82 3 3
4 12 1134.60 50 5.96 1820 542 0.78 / 1431.36 3 3
5 7 1140.68 21 10.08 2000 423 1.20 / 1431.78 3 3
6 13 1169.64 37 11.04 2077 848 2.05 / 1432.63 3 3
7 13 974.04 37 11.92 1773 782 2.83 / 1433.41 3 3
8 13 60.40 37 14.02 444 230 3.06 / 1433.64 3 3
9 8 0.12 190 13.99 344 914 3.98 / 1434.56 3 10
Average= 5.02 (KJ/cycle)

Cycle 284 GMT 31/ 5/2022 13:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 32 14.24 501 228 0.23 / 1426.86 3 3
2 3 949.32 -1 14.24 501 0 0.00 / 1426.86 3 3
3 3 1019.32 1 11.91 1877 22 0.25 / 1426.88 3 3
4 12 1071.32 50 7.30 1807 660 0.91 / 1427.54 3 3
5 7 1078.40 21 10.45 1915 420 1.33 / 1427.96 3 3
6 13 1013.00 37 11.94 1796 793 2.12 / 1428.76 3 3
7 13 808.36 37 12.62 1502 701 2.83 / 1429.46 3 3
8 13 28.40 37 14.11 401 209 3.03 / 1429.67 3 3
9 8 0.28 190 14.01 342 910 3.94 / 1430.58 3 15
Average= 5.02 (KJ/cycle)

Cycle 283 GMT 21/ 5/2022 18:59: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 29 14.20 494 203 0.20 / 1421.60 3 3
2 3 1039.56 1 11.69 1891 22 0.23 / 1421.63 3 3
3 12 1142.52 6 11.26 2035 137 0.36 / 1421.76 3 3
4 12 1981.64 50 9.64 3207 1546 1.91 / 1423.31 3 3
5 7 1976.56 21 10.13 3211 683 2.59 / 1423.99 3 3
6 13 1537.44 37 12.00 2626 1166 3.76 / 1425.16 3 3
7 13 568.76 37 13.46 1182 589 4.35 / 1425.75 3 3
8 8 0.12 190 14.19 329 887 5.23 / 1426.63 3 10
Average= 5.02 (KJ/cycle)

Cycle 282 GMT 20/ 5/2022 14:37:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 29 14.12 508 208 0.21 / 1418.41 3 3
2 3 1027.84 1 11.87 1892 22 0.23 / 1418.43 3 3
3 12 1061.48 6 4.81 1560 45 0.28 / 1418.48 3 3
4 12 1111.68 50 7.22 1873 676 0.95 / 1419.15 3 3
5 7 1110.20 21 10.32 1950 423 1.37 / 1419.58 3 3
6 13 909.00 37 12.08 1670 746 2.12 / 1420.32 3 3
7 13 15.72 37 14.22 348 183 2.30 / 1420.51 3 3
8 8 -0.12 190 14.12 333 893 3.20 / 1421.40 3 15
Average= 5.02 (KJ/cycle)

Cycle 281 GMT 10/ 5/2022 20:35:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 30 14.29 466 200 0.20 / 1414.37 3 3
2 3 1030.24 1 12.00 1876 23 0.22 / 1414.39 3 3
3 3 1023.00 1 11.61 1876 22 0.24 / 1414.41 3 3
4 12 1100.80 50 6.52 1778 580 0.82 / 1414.99 3 3
5 7 1108.64 21 10.42 1949 426 1.25 / 1415.42 3 3
6 13 1089.12 37 11.75 1921 835 2.09 / 1416.25 3 3
7 13 884.48 37 12.43 1617 744 2.83 / 1416.99 3 3
8 13 78.44 37 14.04 476 247 3.08 / 1417.24 3 3
9 8 0.28 190 14.01 361 961 4.04 / 1418.20 3 15
Average= 5.03 (KJ/cycle)

Cycle 280 GMT 1/ 5/2022 2: 4: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 30 14.12 512 217 0.22 / 1410.56 3 3
2 12 1147.64 50 8.72 1954 852 1.07 / 1411.41 3 3
3 7 1152.96 21 10.66 2031 455 1.52 / 1411.87 3 3
4 13 1027.52 37 12.35 1832 837 2.36 / 1412.71 3 3
5 13 587.48 37 13.31 1192 587 2.95 / 1413.29 3 3
6 8 0.00 190 14.19 324 874 3.82 / 1414.17 3 8
Average= 5.03 (KJ/cycle)

Cycle 279 GMT 21/ 4/2022 7:47: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 31 14.09 516 225 0.23 / 1406.42 3 3
2 3 960.08 -1 14.09 516 0 0.00 / 1406.42 3 3
3 12 1130.24 6 11.62 2008 140 0.37 / 1406.56 3 3
4 12 1224.56 50 11.25 2161 1216 1.58 / 1407.77 3 3
5 7 1222.48 21 11.27 2163 512 2.09 / 1408.28 3 3
6 13 1002.16 37 12.87 1785 850 2.94 / 1409.13 3 3
7 13 88.00 37 14.08 490 255 3.20 / 1409.39 3 3
8 8 0.00 190 14.01 359 956 4.15 / 1410.34 3 12
Average= 5.04 (KJ/cycle)

Cycle 278 GMT 20/ 4/2022 5:20: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 32 14.12 516 233 0.23 / 1402.31 3 3
2 3 911.80 -2 14.12 516 0 0.00 / 1402.31 3 3
3 3 1030.64 1 11.95 1894 23 0.26 / 1402.33 3 3
4 12 1169.96 50 5.87 1848 542 0.80 / 1402.87 3 3
5 7 1178.64 21 10.14 2053 437 1.24 / 1403.31 3 3
6 13 1174.12 37 11.59 2034 872 2.11 / 1404.18 3 3
7 13 957.20 37 12.28 1723 783 2.89 / 1404.96 3 3
8 13 104.12 37 13.99 523 271 3.16 / 1405.24 3 3
9 8 0.12 190 14.01 359 956 4.12 / 1406.19 3 11
Average= 5.04 (KJ/cycle)

Cycle 277 GMT 10/ 4/2022 10:32: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 29 14.13 519 213 0.21 / 1398.25 3 3
2 12 1145.32 50 6.48 1831 593 0.81 / 1398.85 3 3
3 7 1152.60 21 10.40 2016 440 1.25 / 1399.29 3 3
4 13 1097.12 37 11.92 1951 860 2.11 / 1400.15 3 3
5 13 889.48 37 12.53 1636 758 2.87 / 1400.91 3 3
6 13 39.92 37 14.09 425 222 3.09 / 1401.13 3 3
7 8 0.04 190 14.00 356 947 4.03 / 1402.07 3 12
Average= 5.04 (KJ/cycle)

Cycle 276 GMT 31/ 3/2022 15:58: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 31 14.08 513 224 0.22 / 1394.49 3 3
2 3 948.36 -1 14.08 513 0 0.00 / 1394.49 3 3
3 12 1081.40 50 8.85 1862 824 1.05 / 1395.32 3 3
4 7 1085.80 21 10.78 1958 443 1.49 / 1395.76 3 3
5 13 964.36 37 12.58 1717 799 2.29 / 1396.56 3 3
6 13 486.96 37 13.51 1049 524 2.81 / 1397.08 3 3
7 8 0.20 190 13.99 360 957 3.77 / 1398.04 3 8
Average= 5.05 (KJ/cycle)

Cycle 275 GMT 21/ 3/2022 21:52: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 30 14.06 521 220 0.22 / 1390.33 3 3
2 3 1019.32 1 11.71 1873 22 0.24 / 1390.35 3 3
3 12 1086.76 6 11.61 1954 136 0.38 / 1390.48 3 3
4 12 1178.92 50 11.30 2068 1168 1.55 / 1391.65 3 3
5 7 1177.20 21 11.32 2059 489 2.04 / 1392.14 3 3
6 13 973.44 37 12.88 1739 829 2.86 / 1392.97 3 3
7 13 218.08 37 13.91 671 345 3.21 / 1393.32 3 3
8 8 0.00 190 14.00 358 952 4.16 / 1394.27 3 9
Average= 5.05 (KJ/cycle)

Cycle 274 GMT 20/ 3/2022 19:23: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 29 14.12 508 208 0.21 / 1386.33 3 3
2 3 1087.68 3 12.23 1974 72 0.28 / 1386.40 3 3
3 12 1084.44 50 6.42 1764 566 0.85 / 1386.97 3 3
4 7 1090.92 21 10.36 1921 418 1.26 / 1387.38 3 3
5 13 1071.64 37 11.88 1884 828 2.09 / 1388.21 3 3
6 13 865.24 37 12.53 1582 733 2.83 / 1388.95 3 3
7 13 16.12 37 14.11 390 204 3.03 / 1389.15 3 3
8 8 0.16 190 13.96 361 958 3.99 / 1390.11 3 16
Average= 5.05 (KJ/cycle)

Cycle 273 GMT 11/ 3/2022 0:52: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 30 14.09 527 223 0.22 / 1382.36 3 3
2 3 1035.36 1 12.15 1903 23 0.25 / 1382.38 3 3
3 12 1084.84 50 6.43 1744 561 0.81 / 1382.94 3 3
4 7 1084.76 21 10.42 1911 418 1.22 / 1383.36 3 3
5 13 1081.28 37 11.94 1897 838 2.06 / 1384.20 3 3
6 13 868.12 37 12.57 1592 740 2.80 / 1384.94 3 3
7 13 40.00 37 14.08 429 223 3.03 / 1385.16 3 3
8 8 0.12 190 14.02 360 959 3.99 / 1386.12 3 11
Average= 5.06 (KJ/cycle)

Cycle 272 GMT 1/ 3/2022 6:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 31 14.04 517 225 0.23 / 1378.50 3 3
2 3 943.44 -1 14.04 517 0 0.00 / 1378.50 3 3
3 3 1021.52 1 12.14 1875 23 0.25 / 1378.52 3 3
4 12 1124.84 50 8.13 1879 764 1.01 / 1379.29 3 3
5 7 1131.48 21 10.82 2008 456 1.47 / 1379.74 3 3
6 13 1034.00 37 12.48 1835 847 2.32 / 1380.59 3 3
7 13 604.84 37 13.38 1200 594 2.91 / 1381.18 3 3
8 8 0.08 190 14.01 357 950 3.86 / 1382.13 3 11
Average= 5.06 (KJ/cycle)

Cycle 271 GMT 19/ 2/2022 11:49: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 31 14.04 518 225 0.23 / 1374.68 3 3
2 3 944.80 -1 14.04 518 0 0.00 / 1374.68 3 3
3 12 1060.52 6 11.60 1901 132 0.36 / 1374.81 3 3
4 12 1061.68 50 11.39 1909 1087 1.44 / 1375.90 3 3
5 7 1059.80 21 11.43 1891 454 1.90 / 1376.35 3 3
6 13 861.04 37 12.99 1581 760 2.66 / 1377.11 3 3
7 13 36.24 37 14.11 410 214 2.87 / 1377.33 3 3
8 8 -0.04 190 14.02 355 946 3.82 / 1378.27 3 14
Average= 5.07 (KJ/cycle)

Cycle 270 GMT 18/ 2/2022 9:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.80 31 14.03 540 235 0.23 / 1371.46 3 3
2 3 952.24 -1 14.03 540 0 0.00 / 1371.46 3 3
3 12 1053.00 6 4.80 1502 43 0.28 / 1371.50 3 3
4 12 1073.60 50 7.17 1821 653 0.93 / 1372.16 3 3
5 7 1070.60 21 10.36 1906 415 1.35 / 1372.57 3 3
6 13 856.00 37 12.43 1584 728 2.07 / 1373.30 3 3
7 13 18.00 37 14.09 398 207 2.28 / 1373.51 3 3
8 8 0.12 190 13.97 358 950 3.23 / 1374.46 3 10
Average= 5.07 (KJ/cycle)

Cycle 269 GMT 8/ 2/2022 15:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 30 14.08 515 218 0.22 / 1367.51 3 3
2 3 1018.60 1 12.09 1872 23 0.24 / 1367.54 3 3
3 12 1052.80 50 6.99 1722 602 0.84 / 1368.14 3 3
4 7 1052.80 21 10.65 1867 418 1.26 / 1368.56 3 3
5 13 1015.16 37 12.32 1779 811 2.07 / 1369.37 3 3
6 13 802.72 37 12.87 1491 710 2.78 / 1370.08 3 3
7 13 5.76 37 14.14 373 195 2.98 / 1370.27 3 3
8 8 0.04 190 14.00 358 952 3.93 / 1371.22 3 12
Average= 5.08 (KJ/cycle)

Cycle 268 GMT 29/ 1/2022 21:18: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 32 14.03 517 232 0.23 / 1363.90 3 3
2 3 935.32 -1 14.03 517 0 0.00 / 1363.90 3 3
3 12 1061.60 50 8.88 1824 810 1.04 / 1364.71 3 3
4 7 1061.64 21 10.93 1914 439 1.48 / 1365.15 3 3
5 13 944.96 37 12.70 1703 800 2.28 / 1365.95 3 3
6 13 294.48 37 13.79 780 398 2.68 / 1366.34 3 3
7 8 0.00 190 14.01 358 953 3.63 / 1367.30 3 9
Average= 5.08 (KJ/cycle)

Cycle 267 GMT 20/ 1/2022 3: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 31 14.00 527 229 0.23 / 1359.69 3 3
2 12 1090.04 6 11.66 1954 137 0.37 / 1359.82 3 3
3 12 1236.44 50 11.17 2174 1214 1.58 / 1361.04 3 3
4 7 1234.28 21 11.23 2168 511 2.09 / 1361.55 3 3
5 13 1035.12 37 12.83 1832 870 2.96 / 1362.42 3 3
6 13 112.56 37 14.00 534 277 3.24 / 1362.70 3 3
7 8 0.16 190 13.99 364 968 4.20 / 1363.66 3 14
Average= 5.09 (KJ/cycle)

Cycle 266 GMT 19/ 1/2022 0:27: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 32 14.00 525 235 0.24 / 1355.58 3 3
2 3 966.56 -1 14.00 525 0 0.00 / 1355.58 3 3
3 3 1025.68 1 11.91 1875 22 0.26 / 1355.60 3 3
4 12 1113.80 50 5.96 1776 529 0.79 / 1356.13 3 3
5 7 1121.60 21 10.29 1965 425 1.21 / 1356.55 3 3
6 13 1171.36 37 11.75 2065 898 2.11 / 1357.45 3 3
7 13 976.64 37 12.40 1761 808 2.92 / 1358.26 3 3
8 13 57.52 37 14.04 452 235 3.15 / 1358.49 3 3
9 8 0.12 190 13.99 363 965 4.12 / 1359.46 3 10
Average= 5.09 (KJ/cycle)

Cycle 265 GMT 9/ 1/2022 5:38: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 31 13.99 527 229 0.23 / 1351.49 3 3
2 3 1013.52 1 11.82 1860 22 0.25 / 1351.51 3 3
3 12 1116.08 50 6.40 1779 569 0.82 / 1352.08 3 3
4 7 1123.60 21 10.40 1970 430 1.25 / 1352.51 3 3
5 13 1133.60 37 11.99 1979 878 2.13 / 1353.39 3 3
6 13 928.16 37 12.58 1692 788 2.92 / 1354.18 3 3
7 13 33.20 37 14.08 418 218 3.13 / 1354.39 3 3
8 8 0.08 190 14.02 356 948 4.08 / 1355.34 3 13
Average= 5.10 (KJ/cycle)

Cycle 264 GMT 30/12/2021 11: 2: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 32 14.00 532 238 0.24 / 1347.57 3 3
2 3 953.28 -1 14.00 532 0 0.00 / 1347.57 3 3
3 3 1017.32 1 12.05 1877 23 0.26 / 1347.59 3 3
4 12 1139.00 50 8.09 1897 767 1.03 / 1348.36 3 3
5 7 1145.44 21 10.81 2001 454 1.48 / 1348.81 3 3
6 13 1043.44 37 12.50 1889 874 2.36 / 1349.69 3 3
7 13 587.28 37 13.42 1202 597 2.95 / 1350.28 3 3
8 8 0.12 190 14.03 366 976 3.93 / 1351.26 3 9
Average= 5.10 (KJ/cycle)

Cycle 263 GMT 20/12/2021 16:42:58

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 32 13.98 520 233 0.23 / 1341.92 3 3
2 3 966.20 -1 13.98 520 0 0.00 / 1341.92 3 3
3 3 1030.72 1 12.00 1893 23 0.26 / 1341.95 3 3
4 12 1139.28 6 11.59 2024 141 0.40 / 1342.09 3 3
5 12 1993.84 50 9.97 3224 1607 2.00 / 1343.69 3 3
6 7 1989.00 21 10.42 3238 709 2.71 / 1344.40 3 3
7 13 1538.44 37 12.29 2585 1175 3.89 / 1345.58 3 3
8 13 560.60 37 13.53 1143 572 4.46 / 1346.15 3 3
9 13 22.48 37 14.12 407 213 4.67 / 1346.36 3 3
10 8 0.12 190 14.02 364 970 5.64 / 1347.33 3 13
Average= 5.10 (KJ/cycle)

Cycle 262 GMT 19/12/2021 12:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 30 13.99 523 220 0.22 / 1337.74 3 3
2 3 1036.04 1 12.26 1892 23 0.24 / 1337.77 3 3
3 12 1127.00 50 5.95 1789 532 0.77 / 1338.30 3 3
4 7 1134.28 21 10.33 1986 431 1.21 / 1338.73 3 3
5 13 1197.68 37 11.77 2123 925 2.13 / 1339.66 3 3
6 13 994.84 37 12.43 1808 832 2.96 / 1340.49 3 3
7 13 55.72 37 14.05 451 234 3.20 / 1340.72 3 3
8 8 -0.20 190 14.01 364 969 4.17 / 1341.69 3 9
Average= 5.10 (KJ/cycle)

Cycle 261 GMT 9/12/2021 17:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 32 14.00 519 233 0.23 / 1333.66 3 3
2 12 1117.04 50 6.44 1797 579 0.81 / 1334.24 3 3
3 7 1124.76 21 10.47 1975 434 1.25 / 1334.67 3 3
4 13 1129.04 37 11.98 2023 897 2.14 / 1335.57 3 3
5 13 919.48 37 12.65 1688 790 2.93 / 1336.36 3 3
6 13 27.76 37 14.10 404 211 3.14 / 1336.57 3 3
7 8 0.24 190 14.02 358 954 4.10 / 1337.53 3 13
Average= 5.11 (KJ/cycle)

Cycle 260 GMT 29/11/2021 22:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 30 14.01 512 215 0.22 / 1329.51 3 3
2 3 1041.36 2 12.56 1909 48 0.26 / 1329.55 3 3
3 3 1013.44 1 11.83 1869 22 0.29 / 1329.58 3 3
4 12 1148.60 50 7.90 1910 754 1.04 / 1330.33 3 3
5 7 1155.00 21 10.81 2029 461 1.50 / 1330.79 3 3
6 13 1057.36 37 12.59 1868 870 2.37 / 1331.66 3 3
7 13 617.76 37 13.40 1229 609 2.98 / 1332.27 3 3
8 13 11.32 37 14.12 388 203 3.18 / 1332.47 3 3
9 8 0.16 190 14.00 359 955 4.14 / 1333.43 3 13
Average= 5.11 (KJ/cycle)

Cycle 259 GMT 20/11/2021 4:23:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 31 13.99 526 228 0.23 / 1324.18 3 3
2 3 1032.96 1 12.19 1913 23 0.25 / 1324.20 3 3
3 12 1122.28 6 11.69 1999 140 0.39 / 1324.34 3 3
4 12 1982.04 50 9.98 3223 1608 2.00 / 1325.95 3 3
5 7 1976.44 21 10.46 3249 714 2.71 / 1326.66 3 3
6 13 1327.32 37 12.58 2269 1056 3.77 / 1327.72 3 3
7 13 593.80 37 13.48 1196 597 4.37 / 1328.32 3 3
8 8 -0.04 190 14.02 366 975 5.34 / 1329.29 3 6
Average= 5.11 (KJ/cycle)

Cycle 258 GMT 19/11/2021 0: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 30 13.97 518 217 0.22 / 1319.96 3 3
2 12 1169.32 50 5.58 1815 506 0.72 / 1320.47 3 3
3 7 1176.24 21 10.18 2051 438 1.16 / 1320.91 3 3
4 13 1241.12 37 11.74 2162 939 2.10 / 1321.85 3 3
5 13 1049.84 37 12.39 1869 857 2.96 / 1322.70 3 3
6 13 146.28 37 13.95 565 292 3.25 / 1322.99 3 3
7 8 -0.08 190 14.00 359 955 4.20 / 1323.95 3 10
Average= 5.11 (KJ/cycle)

Cycle 257 GMT 9/11/2021 5: 9: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 30 13.94 547 229 0.23 / 1315.71 3 3
2 12 1142.68 50 5.94 1808 537 0.77 / 1316.25 3 3
3 7 1148.92 21 10.30 2028 439 1.20 / 1316.68 3 3
4 13 1165.88 37 11.94 2067 913 2.12 / 1317.60 3 3
5 13 979.04 37 12.57 1760 819 2.94 / 1318.42 3 3
6 13 228.28 37 13.84 693 355 3.29 / 1318.77 3 3
7 8 0.04 190 13.97 367 974 4.27 / 1319.75 3 8
Average= 5.12 (KJ/cycle)

Cycle 256 GMT 30/10/2021 10:26:58

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 31 13.98 527 228 0.23 / 1311.88 3 3
2 3 966.64 -1 13.98 527 0 0.00 / 1311.88 3 3
3 3 1032.40 1 12.25 1900 23 0.25 / 1311.90 3 3
4 12 1114.68 50 7.49 1848 692 0.94 / 1312.59 3 3
5 7 1119.44 21 10.77 1981 448 1.39 / 1313.04 3 3
6 13 1021.88 37 12.61 1816 847 2.24 / 1313.89 3 3
7 13 592.60 37 13.41 1198 594 2.83 / 1314.48 3 3
8 8 0.24 190 13.97 376 998 3.83 / 1315.48 3 10
Average= 5.12 (KJ/cycle)

Cycle 255 GMT 20/10/2021 15:59: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 30 13.93 529 221 0.22 / 1306.56 3 3
2 12 1122.92 6 11.70 2005 141 0.36 / 1306.70 3 3
3 12 1950.64 50 9.91 3179 1575 1.94 / 1308.27 3 3
4 7 1945.72 21 10.49 3180 701 2.64 / 1308.97 3 3
5 13 1504.52 37 12.32 2538 1157 3.79 / 1310.13 3 3
6 13 502.56 37 13.57 1065 535 4.33 / 1310.67 3 3
7 8 0.08 190 13.99 370 983 5.31 / 1311.65 3 7
Average= 5.12 (KJ/cycle)

Cycle 254 GMT 19/10/2021 11:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 32 13.89 540 240 0.24 / 1302.42 3 3
2 3 936.44 -1 13.89 540 0 0.00 / 1302.42 3 3
3 12 1122.00 50 5.72 1765 505 0.74 / 1302.93 3 3
4 7 1129.08 21 10.30 1998 432 1.18 / 1303.36 3 3
5 13 1180.12 37 11.92 2079 917 2.09 / 1304.28 3 3
6 13 979.60 37 12.61 1756 819 2.91 / 1305.10 3 3
7 13 104.12 37 13.96 518 268 3.18 / 1305.37 3 3
8 8 0.16 190 13.96 366 971 4.15 / 1306.34 3 9
Average= 5.12 (KJ/cycle)

Cycle 253 GMT 9/10/2021 17: 1: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 31 13.92 526 227 0.23 / 1298.37 3 3
2 12 1091.16 50 6.04 1741 526 0.75 / 1298.90 3 3
3 7 1098.48 21 10.38 1948 425 1.18 / 1299.32 3 3
4 13 1124.76 37 12.09 1986 888 2.07 / 1300.21 3 3
5 13 914.80 37 12.75 1654 780 2.85 / 1300.99 3 3
6 13 36.60 37 14.05 422 219 3.07 / 1301.21 3 3
7 8 0.28 190 13.95 368 975 4.04 / 1302.18 3 10
Average= 5.13 (KJ/cycle)

Cycle 252 GMT 29/ 9/2021 22:21: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 31 13.96 531 230 0.23 / 1294.57 3 3
2 12 1095.44 50 7.68 1841 707 0.94 / 1295.28 3 3
3 7 1099.68 21 10.81 1967 447 1.38 / 1295.72 3 3
4 13 1011.40 37 12.60 1814 846 2.23 / 1296.57 3 3
5 13 585.84 37 13.41 1181 586 2.81 / 1297.16 3 3
6 8 0.60 190 13.97 372 987 3.80 / 1298.14 3 5
Average= 5.13 (KJ/cycle)

Cycle 251 GMT 20/ 9/2021 3:59: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 32 13.94 518 231 0.23 / 1289.34 3 3
2 3 968.96 -1 13.94 518 0 0.00 / 1289.34 3 3
3 3 1021.96 1 11.91 1876 22 0.25 / 1289.36 3 3
4 12 1116.76 6 11.62 2002 140 0.39 / 1289.50 3 3
5 12 1959.64 50 9.89 3192 1578 1.97 / 1291.08 3 3
6 7 1954.40 21 10.54 3197 708 2.68 / 1291.79 3 3
7 13 1266.68 37 12.63 2198 1027 3.71 / 1292.81 3 3
8 13 503.96 37 13.55 1069 536 4.24 / 1293.35 3 3
9 8 -0.04 190 13.97 374 993 5.23 / 1294.34 3 3
Average= 5.14 (KJ/cycle)

Cycle 250 GMT 18/ 9/2021 23:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 31 13.95 528 228 0.23 / 1285.24 3 3
2 3 1019.92 1 11.97 1866 22 0.25 / 1285.27 3 3
3 3 1022.48 1 11.81 1881 22 0.27 / 1285.29 3 3
4 12 1081.20 50 5.84 1707 498 0.77 / 1285.79 3 3
5 7 1088.32 21 10.48 1927 424 1.20 / 1286.21 3 3
6 13 1132.08 37 12.24 2002 907 2.10 / 1287.12 3 3
7 13 929.56 37 12.82 1696 804 2.91 / 1287.92 3 3
8 13 29.76 37 14.06 412 214 3.12 / 1288.14 3 3
9 8 0.04 190 13.96 366 971 4.09 / 1289.11 3 9
Average= 5.14 (KJ/cycle)

Cycle 249 GMT 9/ 9/2021 5:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 32 13.95 526 235 0.23 / 1281.03 3 3
2 3 964.20 -1 13.95 526 0 0.00 / 1281.03 3 3
3 3 1035.00 1 12.05 1911 23 0.26 / 1281.05 3 3
4 12 1127.16 50 5.66 1754 496 0.75 / 1281.55 3 3
5 7 1133.52 21 10.34 1988 432 1.19 / 1281.98 3 3
6 13 1203.00 37 12.07 2124 949 2.13 / 1282.93 3 3
7 13 989.88 37 12.73 1785 841 2.98 / 1283.77 3 3
8 13 123.16 37 13.95 548 283 3.26 / 1284.05 3 3
9 8 0.04 190 14.00 363 966 4.22 / 1285.01 3 13
Average= 5.14 (KJ/cycle)

Cycle 248 GMT 30/ 8/2021 10:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 32 13.93 526 234 0.23 / 1277.26 3 3
2 12 1079.44 50 7.74 1814 702 0.94 / 1277.96 3 3
3 7 1086.60 21 10.91 1952 447 1.38 / 1278.41 3 3
4 13 997.48 37 12.69 1795 843 2.23 / 1279.25 3 3
5 13 540.48 37 13.45 1134 564 2.79 / 1279.81 3 3
6 8 0.08 190 14.01 367 977 3.77 / 1280.79 3 10
Average= 5.14 (KJ/cycle)

Cycle 247 GMT 20/ 8/2021 15:59: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 32 13.92 522 233 0.23 / 1273.51 3 3
2 12 993.64 50 11.41 1825 1041 1.27 / 1274.55 3 3
3 7 993.24 21 11.54 1834 444 1.72 / 1275.00 3 3
4 13 831.08 37 13.05 1561 754 2.47 / 1275.75 3 3
5 13 165.64 37 13.90 605 311 2.78 / 1276.06 3 3
6 8 0.24 190 14.01 361 961 3.74 / 1277.02 3 15
Average= 5.15 (KJ/cycle)

Cycle 246 GMT 19/ 8/2021 13:45: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 31 13.90 531 229 0.23 / 1270.14 3 3
2 3 929.24 -1 13.90 531 0 0.00 / 1270.14 3 3
3 3 1030.28 1 11.91 1900 23 0.25 / 1270.16 3 3
4 12 1089.32 6 4.76 1336 38 0.29 / 1270.20 3 3
5 12 1157.08 50 5.84 1908 557 0.85 / 1270.76 3 3
6 7 1157.56 21 10.29 2026 438 1.28 / 1271.20 3 3
7 13 993.96 37 12.60 1781 830 2.11 / 1272.03 3 3
8 13 127.08 37 13.94 550 284 2.40 / 1272.31 3 3
9 8 -0.16 190 14.01 364 969 3.37 / 1273.28 3 10
Average= 5.15 (KJ/cycle)

Cycle 245 GMT 9/ 8/2021 19:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 32 13.96 522 233 0.23 / 1267.36 3 3
2 7 1161.44 21 5.21 1677 183 0.42 / 1267.55 3 3
3 13 865.60 37 12.61 1593 743 1.16 / 1268.29 3 3
4 13 679.12 37 13.10 1332 646 1.81 / 1268.93 3 3
5 8 0.24 190 13.98 368 977 2.78 / 1269.91 3 11
Average= 5.16 (KJ/cycle)

Cycle 244 GMT 1/ 8/2021 15:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 30 13.97 512 215 0.21 / 1263.61 3 3
2 3 1022.68 1 12.10 1879 23 0.24 / 1263.63 3 3
3 3 1017.00 1 11.59 1858 22 0.26 / 1263.65 3 3
4 12 1139.24 50 7.32 1873 686 0.94 / 1264.34 3 3
5 7 1145.76 21 10.78 2010 455 1.40 / 1264.79 3 3
6 13 1073.44 37 12.56 1926 895 2.29 / 1265.69 3 3
7 13 422.20 37 13.63 959 484 2.78 / 1266.17 3 3
8 8 0.24 190 14.04 359 958 3.74 / 1267.13 3 7
Average= 5.17 (KJ/cycle)

Cycle 243 GMT 22/ 7/2021 20:52: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 30 13.94 520 217 0.22 / 1258.20 3 3
2 3 1031.36 1 12.12 1897 23 0.24 / 1258.22 3 3
3 12 1118.64 6 11.59 1993 139 0.38 / 1258.36 3 3
4 12 1981.72 50 9.81 3206 1573 1.95 / 1259.93 3 3
5 7 1976.96 21 10.50 3224 711 2.66 / 1260.64 3 3
6 13 1530.32 37 12.28 2618 1190 3.85 / 1261.83 3 3
7 13 576.64 37 13.46 1186 591 4.44 / 1262.42 3 3
8 8 -0.20 190 14.03 365 973 5.42 / 1263.39 3 9
Average= 5.18 (KJ/cycle)

Cycle 242 GMT 21/ 7/2021 16:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 31 13.95 513 222 0.22 / 1254.10 3 3
2 12 1098.08 50 5.75 1735 499 0.72 / 1254.60 3 3
3 7 1103.68 21 10.44 1941 426 1.15 / 1255.02 3 3
4 13 1165.72 37 12.05 2067 922 2.07 / 1255.95 3 3
5 13 975.40 37 12.69 1774 833 2.90 / 1256.78 3 3
6 13 52.12 37 14.02 448 232 3.13 / 1257.01 3 3
7 8 0.40 190 13.98 364 967 4.10 / 1257.98 3 11
Average= 5.18 (KJ/cycle)

Cycle 241 GMT 11/ 7/2021 21:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 31 13.96 531 230 0.23 / 1249.91 3 3
2 3 961.68 -1 13.96 531 0 0.00 / 1249.91 3 3
3 3 1038.48 1 11.89 1903 23 0.25 / 1249.94 3 3
4 12 1148.16 50 5.59 1777 497 0.75 / 1250.43 3 3
5 7 1155.28 21 10.29 2014 435 1.18 / 1250.87 3 3
6 13 1221.00 37 12.07 2132 952 2.14 / 1251.82 3 3
7 13 1013.40 37 12.70 1818 854 2.99 / 1252.67 3 3
8 13 61.44 37 14.01 458 237 3.23 / 1252.91 3 3
9 8 -0.04 190 14.00 363 966 4.19 / 1253.88 3 15
Average= 5.18 (KJ/cycle)

Cycle 240 GMT 2/ 7/2021 2:49: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 30 13.95 530 222 0.22 / 1245.80 3 3
2 3 1014.76 1 11.39 1876 21 0.24 / 1245.82 3 3
3 12 1100.24 50 7.32 1825 668 0.91 / 1246.49 3 3
4 7 1106.32 21 10.77 1969 445 1.36 / 1246.94 3 3
5 13 1025.88 37 12.58 1860 866 2.22 / 1247.80 3 3
6 13 806.56 37 13.06 1526 737 2.96 / 1248.54 3 3
7 13 23.32 37 14.08 392 204 3.16 / 1248.74 3 3
8 8 -0.12 190 14.03 353 941 4.10 / 1249.68 3 11
Average= 5.19 (KJ/cycle)

Cycle 239 GMT 22/ 6/2021 8:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 30 13.93 521 218 0.22 / 1240.56 3 3
2 12 1101.08 6 11.46 1982 136 0.35 / 1240.69 3 3
3 12 1985.72 50 9.58 3207 1536 1.89 / 1242.23 3 3
4 7 1982.92 21 10.46 3236 711 2.60 / 1242.94 3 3
5 13 1327.68 37 12.60 2252 1050 3.65 / 1243.99 3 3
6 13 611.68 37 13.44 1237 615 4.27 / 1244.61 3 3
7 8 0.64 190 14.04 365 974 5.24 / 1245.58 3 13
Average= 5.19 (KJ/cycle)

Cycle 238 GMT 21/ 6/2021 4: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 31 13.92 516 223 0.22 / 1236.49 3 3
2 12 1095.24 50 5.83 1738 507 0.73 / 1237.00 3 3
3 7 1103.04 21 10.45 1940 426 1.16 / 1237.42 3 3
4 13 1169.16 37 12.11 2080 932 2.09 / 1238.35 3 3
5 13 965.40 37 12.75 1749 825 2.91 / 1239.18 3 3
6 13 36.80 37 14.04 415 216 3.13 / 1239.40 3 3
7 8 0.00 190 14.00 355 944 4.07 / 1240.34 3 15
Average= 5.19 (KJ/cycle)

Cycle 237 GMT 11/ 6/2021 9:22: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 30 13.88 538 224 0.22 / 1232.35 3 3
2 12 1125.16 50 5.78 1770 512 0.74 / 1232.87 3 3
3 7 1133.76 21 10.45 1987 436 1.17 / 1233.30 3 3
4 13 1181.20 37 12.19 2109 951 2.12 / 1234.25 3 3
5 13 991.20 37 12.78 1790 846 2.97 / 1235.10 3 3
6 13 20.00 37 14.06 397 207 3.18 / 1235.31 3 3
7 8 -0.08 190 13.97 362 961 4.14 / 1236.27 3 15
Average= 5.19 (KJ/cycle)

Cycle 236 GMT 1/ 6/2021 14:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 31 13.93 523 226 0.23 / 1228.18 3 3
2 3 957.84 -1 13.93 523 0 0.00 / 1228.18 3 3
3 3 1016.64 1 11.76 1857 22 0.25 / 1228.20 3 3
4 12 1113.20 50 7.40 1847 683 0.93 / 1228.88 3 3
5 7 1118.36 21 10.94 1968 452 1.38 / 1229.33 3 3
6 13 1043.20 37 12.76 1838 868 2.25 / 1230.20 3 3
7 13 833.68 37 13.11 1538 746 3.00 / 1230.95 3 3
8 13 48.24 37 14.05 432 225 3.22 / 1231.17 3 3
9 8 0.08 190 14.02 360 959 4.18 / 1232.13 3 10
Average= 5.20 (KJ/cycle)

Cycle 235 GMT 22/ 5/2021 20:29: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 30 13.93 519 217 0.22 / 1223.18 3 3
2 12 1115.40 6 11.48 1993 137 0.35 / 1223.31 3 3
3 12 1667.36 50 10.26 2777 1425 1.78 / 1224.74 3 3
4 7 1665.80 21 10.80 2792 633 2.41 / 1225.37 3 3
5 13 1450.68 37 12.40 2466 1131 3.54 / 1226.50 3 3
6 13 432.40 37 13.63 967 488 4.03 / 1226.99 3 3
7 8 0.08 190 14.04 360 960 4.99 / 1227.95 3 10
Average= 5.20 (KJ/cycle)

Cycle 234 GMT 21/ 5/2021 17: 2: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 29 13.94 516 209 0.21 / 1218.93 3 3
2 3 1041.12 2 12.06 1904 46 0.25 / 1218.98 3 3
3 12 1137.52 50 5.89 1795 529 0.78 / 1219.51 3 3
4 7 1145.24 21 10.53 2004 443 1.23 / 1219.95 3 3
5 13 1193.44 37 12.26 2093 949 2.18 / 1220.90 3 3
6 13 994.08 37 12.81 1767 838 3.01 / 1221.74 3 3
7 13 109.04 37 13.95 520 268 3.28 / 1222.01 3 3
8 8 0.48 190 14.02 358 954 4.24 / 1222.96 3 13
Average= 5.20 (KJ/cycle)

Cycle 233 GMT 11/ 5/2021 22:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 30 13.91 533 222 0.22 / 1214.79 3 3
2 3 1024.40 1 11.92 1878 22 0.24 / 1214.81 3 3
3 12 1109.48 50 5.99 1759 527 0.77 / 1215.34 3 3
4 7 1116.44 21 10.52 1952 431 1.20 / 1215.77 3 3
5 13 1167.80 37 12.24 2057 932 2.13 / 1216.70 3 3
6 13 959.12 37 12.82 1743 827 2.96 / 1217.53 3 3
7 13 82.92 37 14.00 479 248 3.21 / 1217.78 3 3
8 8 0.08 190 14.04 355 947 4.16 / 1218.72 3 17
Average= 5.21 (KJ/cycle)

Cycle 232 GMT 2/ 5/2021 3:28: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 30 13.92 531 222 0.22 / 1210.96 3 3
2 12 1113.12 50 7.81 1861 727 0.95 / 1211.69 3 3
3 7 1118.84 21 10.94 1974 454 1.40 / 1212.14 3 3
4 13 1024.44 37 12.63 1875 876 2.28 / 1213.02 3 3
5 13 588.64 37 13.39 1200 595 2.87 / 1213.61 3 3
6 8 -0.12 190 14.04 359 958 3.83 / 1214.57 3 9
Average= 5.21 (KJ/cycle)

Cycle 231 GMT 22/ 4/2021 9: 6: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 31 13.91 523 226 0.23 / 1205.83 3 3
2 3 973.52 -1 13.91 523 0 0.00 / 1205.83 3 3
3 3 1039.16 1 11.85 1891 22 0.25 / 1205.86 3 3
4 12 1134.40 6 11.56 2026 141 0.39 / 1206.00 3 3
5 12 1960.76 50 9.82 3185 1564 1.95 / 1207.56 3 3
6 7 1955.56 21 10.55 3198 709 2.66 / 1208.27 3 3
7 13 1287.16 37 12.61 2244 1047 3.71 / 1209.32 3 3
8 13 367.12 37 13.69 891 451 4.16 / 1209.77 3 3
9 8 0.04 190 14.05 363 969 5.13 / 1210.74 3 12
Average= 5.22 (KJ/cycle)

Cycle 230 GMT 21/ 4/2021 4:38: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 31 13.94 514 222 0.22 / 1201.60 3 3
2 3 947.12 -1 13.94 514 0 0.00 / 1201.60 3 3
3 3 1014.68 1 11.37 1884 21 0.24 / 1201.62 3 3
4 12 1137.72 50 5.91 1794 530 0.77 / 1202.15 3 3
5 7 1145.76 21 10.52 2006 443 1.22 / 1202.59 3 3
6 13 1191.20 37 12.25 2090 947 2.16 / 1203.54 3 3
7 13 984.48 37 12.80 1770 838 3.00 / 1204.38 3 3
8 13 106.08 37 13.95 519 268 3.27 / 1204.65 3 3
9 8 0.68 190 14.00 362 963 4.23 / 1205.61 3 14
Average= 5.22 (KJ/cycle)

Cycle 229 GMT 11/ 4/2021 9:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 30 13.91 529 221 0.22 / 1197.23 3 3
2 12 1119.24 50 6.01 1786 537 0.76 / 1197.77 3 3
3 7 1125.52 21 10.43 2003 439 1.20 / 1198.21 3 3
4 13 1176.36 37 12.14 2101 944 2.14 / 1199.15 3 3
5 13 964.92 37 12.80 1745 826 2.97 / 1199.98 3 3
6 13 77.60 37 13.97 481 249 3.21 / 1200.22 3 3
7 13 11.80 37 14.07 384 200 3.41 / 1200.42 3 4
8 8 -0.28 190 13.99 358 952 4.37 / 1201.38 3 17
Average= 5.22 (KJ/cycle)

Cycle 228 GMT 1/ 4/2021 15: 5: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 30 13.92 525 219 0.22 / 1193.43 3 3
2 12 1120.12 50 7.53 1869 704 0.92 / 1194.13 3 3
3 7 1125.96 21 10.85 1996 455 1.38 / 1194.58 3 3
4 13 1033.68 37 12.63 1869 873 2.25 / 1195.46 3 3
5 13 587.08 37 13.36 1204 595 2.85 / 1196.05 3 3
6 8 0.32 190 14.01 359 956 3.80 / 1197.01 3 13
Average= 5.23 (KJ/cycle)

Cycle 227 GMT 22/ 3/2021 20:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 31 13.91 517 223 0.22 / 1188.09 3 3
2 12 1105.00 6 11.52 1976 137 0.36 / 1188.23 3 3
3 12 1973.96 50 9.66 3196 1544 1.90 / 1189.77 3 3
4 7 1968.96 21 10.51 3220 711 2.61 / 1190.48 3 3
5 13 1518.64 37 12.35 2581 1179 3.79 / 1191.66 3 3
6 13 565.20 37 13.47 1157 577 4.37 / 1192.24 3 3
7 8 0.12 190 14.03 364 970 5.34 / 1193.21 3 10
Average= 5.23 (KJ/cycle)

Cycle 226 GMT 21/ 3/2021 16:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 30 13.89 530 221 0.22 / 1183.93 3 3
2 3 1014.04 1 11.42 1889 22 0.24 / 1183.95 3 3
3 12 1138.84 50 6.11 1813 554 0.80 / 1184.50 3 3
4 7 1146.20 21 10.57 2010 446 1.24 / 1184.95 3 3
5 13 1159.92 37 12.34 2047 935 2.18 / 1185.88 3 3
6 13 949.72 37 12.88 1701 811 2.99 / 1186.69 3 3
7 13 38.80 37 14.04 400 208 3.20 / 1186.90 3 3
8 8 0.24 190 14.00 363 966 4.16 / 1187.87 3 12
Average= 5.23 (KJ/cycle)

Cycle 225 GMT 11/ 3/2021 21:44: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 30 13.91 515 215 0.21 / 1180.02 3 3
2 12 1114.56 50 6.21 1793 557 0.77 / 1180.57 3 3
3 7 1121.92 21 10.59 1976 439 1.21 / 1181.01 3 3
4 13 1133.24 37 12.29 2034 925 2.14 / 1181.94 3 3
5 13 930.48 37 12.87 1689 804 2.94 / 1182.74 3 3
6 8 0.40 190 14.00 362 963 3.90 / 1183.71 3 6
Average= 5.24 (KJ/cycle)

Cycle 224 GMT 2/ 3/2021 3: 6: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 30 13.88 535 223 0.22 / 1176.20 3 3
2 12 1126.72 50 7.93 1883 747 0.97 / 1176.95 3 3
3 7 1132.92 21 11.00 1991 460 1.43 / 1177.41 3 3
4 13 1029.12 37 12.76 1821 860 2.29 / 1178.27 3 3
5 13 578.00 37 13.40 1186 588 2.88 / 1178.85 3 3
6 8 0.24 190 14.02 356 948 3.83 / 1179.80 3 12
Average= 5.24 (KJ/cycle)

Cycle 223 GMT 20/ 2/2021 8:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 31 13.88 532 229 0.23 / 1170.87 3 3
2 12 1116.00 6 11.59 2002 139 0.37 / 1171.01 3 3
3 12 1969.44 50 9.84 3185 1567 1.94 / 1172.58 3 3
4 7 1964.44 21 10.52 3201 707 2.64 / 1173.29 3 3
5 13 1515.20 37 12.36 2562 1172 3.81 / 1174.46 3 3
6 13 529.96 37 13.50 1103 551 4.36 / 1175.01 3 3
7 8 -0.12 190 14.02 364 970 5.33 / 1175.98 3 15
Average= 5.25 (KJ/cycle)

Cycle 222 GMT 19/ 2/2021 4:27: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 31 13.90 527 227 0.23 / 1166.73 3 3
2 3 970.12 -1 13.90 527 0 0.00 / 1166.73 3 3
3 3 1031.24 1 11.83 1882 22 0.25 / 1166.75 3 3
4 12 1137.84 50 6.36 1831 582 0.83 / 1167.34 3 3
5 7 1144.84 21 10.66 2009 450 1.28 / 1167.78 3 3
6 13 1128.80 37 12.42 2004 921 2.20 / 1168.71 3 3
7 13 912.20 37 12.91 1660 793 3.00 / 1169.50 3 3
8 13 36.16 37 14.03 408 212 3.21 / 1169.71 3 3
9 8 -0.04 190 14.02 350 932 4.14 / 1170.64 3 13
Average= 5.25 (KJ/cycle)

Cycle 221 GMT 9/ 2/2021 9:56: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 31 13.89 511 220 0.22 / 1162.78 3 3
2 3 955.72 -1 13.89 511 0 0.00 / 1162.78 3 3
3 3 1023.32 1 11.71 1870 22 0.24 / 1162.80 3 3
4 12 1130.24 50 6.40 1823 583 0.83 / 1163.38 3 3
5 7 1137.04 21 10.69 2000 449 1.27 / 1163.83 3 3
6 13 1110.32 37 12.49 1961 906 2.18 / 1164.74 3 3
7 13 899.80 37 12.95 1648 790 2.97 / 1165.53 3 3
8 8 0.12 190 13.99 367 976 3.95 / 1166.50 3 9
Average= 5.25 (KJ/cycle)

Cycle 220 GMT 30/ 1/2021 15:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 29 13.92 513 207 0.21 / 1159.02 3 3
2 3 1047.04 2 12.49 1927 48 0.26 / 1159.07 3 3
3 12 1120.68 50 8.15 1890 770 1.03 / 1159.84 3 3
4 7 1127.16 21 11.05 1988 461 1.49 / 1160.30 3 3
5 13 1014.48 37 12.78 1796 849 2.34 / 1161.15 3 3
6 13 364.12 37 13.64 884 446 2.78 / 1161.59 3 3
7 8 0.28 190 14.00 363 966 3.75 / 1162.56 3 11
Average= 5.26 (KJ/cycle)

Cycle 219 GMT 20/ 1/2021 20:53: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 31 13.85 530 228 0.23 / 1153.82 3 3
2 3 967.40 -1 13.85 530 0 0.00 / 1153.82 3 3
3 3 1030.60 1 11.82 1885 22 0.25 / 1153.84 3 3
4 12 1128.08 6 11.67 2008 141 0.39 / 1153.98 3 3
5 12 1963.12 50 9.83 3191 1568 1.96 / 1155.55 3 3
6 7 1958.12 21 10.51 3196 705 2.66 / 1156.26 3 3
7 13 1498.68 37 12.36 2528 1156 3.82 / 1157.41 3 3
8 13 342.68 37 13.69 852 432 4.25 / 1157.85 3 3
9 8 0.00 190 14.03 362 965 5.22 / 1158.81 3 10
Average= 5.27 (KJ/cycle)

Cycle 218 GMT 19/ 1/2021 16:22: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 31 13.90 518 223 0.22 / 1149.95 3 3
2 12 1104.04 50 6.74 1815 612 0.83 / 1150.56 3 3
3 7 1110.48 21 10.79 1954 443 1.28 / 1151.00 3 3
4 13 1058.48 37 12.48 1913 883 2.16 / 1151.88 3 3
5 13 842.28 37 12.99 1568 754 2.91 / 1152.64 3 3
6 8 0.48 190 13.99 360 957 3.87 / 1153.59 3 8
Average= 5.27 (KJ/cycle)

Cycle 217 GMT 9/ 1/2021 21:58: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 31 13.87 536 230 0.23 / 1145.78 3 3
2 3 973.36 -1 13.87 536 0 0.00 / 1145.78 3 3
3 12 1162.76 50 6.43 1865 600 0.83 / 1146.38 3 3
4 7 1169.56 21 10.69 2045 459 1.29 / 1146.84 3 3
5 13 1130.80 37 12.45 2018 930 2.22 / 1147.77 3 3
6 13 925.60 37 12.91 1688 806 3.03 / 1148.57 3 3
7 13 2.28 37 14.09 370 193 3.22 / 1148.77 3 3
8 8 -0.04 190 14.02 359 956 4.17 / 1149.72 3 11
Average= 5.27 (KJ/cycle)

Cycle 216 GMT 31/12/2020 3:18:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 31 13.90 522 225 0.22 / 1142.08 3 3
2 12 1089.20 50 8.44 1860 785 1.01 / 1142.87 3 3
3 7 1094.84 21 11.17 1942 456 1.47 / 1143.32 3 3
4 13 972.28 37 12.82 1769 839 2.30 / 1144.16 3 3
5 13 315.48 37 13.67 819 414 2.72 / 1144.57 3 3
6 8 0.08 190 14.00 366 974 3.69 / 1145.55 3 10
Average= 5.28 (KJ/cycle)

Cycle 215 GMT 21/12/2020 8:53: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 31 13.85 533 229 0.23 / 1136.75 3 3
2 12 1088.60 6 11.87 1955 139 0.37 / 1136.89 3 3
3 12 1960.04 50 9.95 3184 1584 1.95 / 1138.47 3 3
4 7 1954.80 21 10.54 3210 711 2.66 / 1139.18 3 3
5 13 1496.96 37 12.40 2516 1154 3.82 / 1140.34 3 3
6 13 519.76 37 13.50 1105 552 4.37 / 1140.89 3 3
7 8 0.12 190 14.04 363 968 5.34 / 1141.86 3 14
Average= 5.29 (KJ/cycle)

Cycle 214 GMT 20/12/2020 4:31:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 31 13.89 540 233 0.23 / 1132.61 3 3
2 12 1133.80 50 6.50 1841 598 0.83 / 1133.20 3 3
3 7 1140.76 21 10.71 1996 449 1.28 / 1133.65 3 3
4 13 1101.88 37 12.45 1975 910 2.19 / 1134.56 3 3
5 13 886.32 37 12.93 1644 787 2.98 / 1135.35 3 3
6 13 31.48 37 14.02 412 214 3.19 / 1135.56 3 3
7 8 0.04 190 14.01 359 956 4.15 / 1136.52 3 18
Average= 5.29 (KJ/cycle)

Cycle 213 GMT 10/12/2020 10: 3:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 31 13.88 526 226 0.23 / 1128.65 3 3
2 12 1124.72 50 6.81 1850 630 0.86 / 1129.28 3 3
3 7 1131.40 21 10.80 1999 453 1.31 / 1129.73 3 3
4 13 1077.20 37 12.52 1947 902 2.21 / 1130.63 3 3
5 13 859.12 37 12.98 1606 771 2.98 / 1131.40 3 3
6 8 0.32 190 14.00 364 968 3.95 / 1132.37 3 7
Average= 5.29 (KJ/cycle)

Cycle 212 GMT 30/11/2020 15:38: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 31 13.88 528 227 0.23 / 1124.74 3 3
2 12 1118.04 50 8.20 1909 783 1.01 / 1125.52 3 3
3 7 1124.32 21 11.07 2017 469 1.48 / 1125.99 3 3
4 13 1009.36 37 12.75 1831 864 2.34 / 1126.86 3 3
5 13 556.48 37 13.39 1168 579 2.92 / 1127.44 3 3
6 8 0.92 190 13.99 371 986 3.91 / 1128.42 3 7
Average= 5.30 (KJ/cycle)

Cycle 211 GMT 20/11/2020 21:18: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 31 13.89 530 228 0.23 / 1119.37 3 3
2 12 1104.64 6 11.83 1976 140 0.37 / 1119.51 3 3
3 12 1978.76 50 9.85 3208 1580 1.95 / 1121.09 3 3
4 7 1973.80 21 10.51 3234 714 2.66 / 1121.81 3 3
5 13 1523.04 37 12.36 2550 1166 3.83 / 1122.97 3 3
6 13 537.48 37 13.46 1138 567 4.40 / 1123.54 3 3
7 8 0.04 190 14.03 366 976 5.37 / 1124.51 3 12
Average= 5.30 (KJ/cycle)

Cycle 210 GMT 19/11/2020 17: 5: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 30 13.87 522 217 0.22 / 1115.39 3 3
2 12 1141.56 50 6.78 1880 637 0.85 / 1116.03 3 3
3 7 1148.96 21 10.80 2017 457 1.31 / 1116.49 3 3
4 13 1088.68 37 12.55 1960 910 2.22 / 1117.40 3 3
5 13 879.92 37 12.97 1634 784 3.01 / 1118.18 3 3
6 8 0.12 190 14.00 362 963 3.97 / 1119.14 3 12
Average= 5.30 (KJ/cycle)

Cycle 209 GMT 9/11/2020 22:39:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 29 13.86 529 213 0.21 / 1111.31 3 3
2 3 1036.88 1 12.34 1918 24 0.24 / 1111.33 3 3
3 12 1150.96 50 7.02 1889 663 0.90 / 1111.99 3 3
4 7 1157.08 21 10.91 2026 464 1.36 / 1112.46 3 3
5 13 1081.32 37 12.64 1921 898 2.26 / 1113.35 3 3
6 13 652.68 37 13.29 1302 640 2.90 / 1114.00 3 3
7 13 17.36 37 14.05 398 207 3.11 / 1114.20 3 3
8 8 0.04 190 14.02 365 972 4.08 / 1115.17 3 16
Average= 5.31 (KJ/cycle)

Cycle 208 GMT 31/10/2020 4: 7:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 31 13.87 546 235 0.23 / 1107.44 3 3
2 3 943.92 -1 13.87 546 0 0.00 / 1107.44 3 3
3 12 1120.96 50 8.44 1914 808 1.04 / 1108.25 3 3
4 7 1126.28 21 11.16 1988 466 1.51 / 1108.71 3 3
5 13 1001.32 37 12.82 1792 850 2.36 / 1109.56 3 3
6 13 533.56 37 13.43 1117 555 2.91 / 1110.12 3 3
7 8 0.08 190 14.00 367 976 3.89 / 1111.09 3 9
Average= 5.32 (KJ/cycle)

Cycle 207 GMT 21/10/2020 9:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 31 13.87 531 228 0.23 / 1101.87 3 3
2 12 1107.16 6 11.88 2006 143 0.37 / 1102.02 3 3
3 12 1967.40 50 9.95 3200 1592 1.96 / 1103.61 3 3
4 7 1962.40 21 10.51 3220 711 2.67 / 1104.32 3 3
5 13 1487.08 37 12.37 2495 1142 3.82 / 1105.46 3 3
6 13 522.80 37 13.47 1105 551 4.37 / 1106.01 3 3
7 13 10.88 37 14.05 395 205 4.57 / 1106.22 3 3
8 8 0.48 190 14.01 371 988 5.56 / 1107.20 3 9
Average= 5.32 (KJ/cycle)

Cycle 206 GMT 20/10/2020 5:45: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 31 13.86 532 229 0.23 / 1097.92 3 3
2 3 959.12 -1 13.86 532 0 0.00 / 1097.92 3 3
3 3 1019.44 1 11.82 1877 22 0.25 / 1097.94 3 3
4 12 1129.52 50 6.90 1871 645 0.90 / 1098.58 3 3
5 7 1136.84 21 10.83 1997 454 1.35 / 1099.04 3 3
6 13 1068.32 37 12.60 1888 880 2.23 / 1099.92 3 3
7 13 848.52 37 13.00 1577 759 2.99 / 1100.68 3 3
8 8 0.44 190 13.98 364 967 3.96 / 1101.64 3 7
Average= 5.32 (KJ/cycle)

Cycle 205 GMT 10/10/2020 11:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 31 13.86 533 229 0.23 / 1093.80 3 3
2 3 971.92 -1 13.86 533 0 0.00 / 1093.80 3 3
3 3 1041.52 2 12.17 1910 46 0.28 / 1093.84 3 3
4 12 1120.56 50 6.91 1860 643 0.92 / 1094.49 3 3
5 7 1127.08 21 10.86 1984 452 1.37 / 1094.94 3 3
6 13 1064.24 37 12.60 1900 886 2.26 / 1095.82 3 3
7 13 648.20 37 13.28 1293 635 2.89 / 1096.46 3 3
8 13 64.56 37 13.96 469 242 3.13 / 1096.70 3 3
9 8 0.12 190 13.99 371 986 4.12 / 1097.69 3 13
Average= 5.33 (KJ/cycle)

Cycle 204 GMT 30/ 9/2020 16:48:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 31 13.88 526 226 0.23 / 1089.89 3 3
2 12 1123.72 50 8.27 1914 791 1.02 / 1090.68 3 3
3 7 1129.32 21 11.10 2002 467 1.48 / 1091.14 3 3
4 13 1006.76 37 12.73 1829 861 2.35 / 1092.01 3 3
5 13 558.64 37 13.40 1157 574 2.92 / 1092.58 3 3
6 8 0.40 190 13.98 372 988 3.91 / 1093.57 3 10
Average= 5.33 (KJ/cycle)

Cycle 203 GMT 20/ 9/2020 22:35:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 31 13.80 544 233 0.23 / 1084.53 3 3
2 12 1113.84 6 11.83 1989 141 0.37 / 1084.67 3 3
3 12 1972.48 50 9.81 3202 1571 1.94 / 1086.24 3 3
4 7 1967.52 21 10.45 3237 710 2.65 / 1086.95 3 3
5 13 1512.36 37 12.30 2575 1172 3.83 / 1088.12 3 3
6 13 530.80 37 13.47 1107 552 4.38 / 1088.67 3 3
7 8 -0.04 190 14.00 371 987 5.37 / 1089.66 3 5
Average= 5.34 (KJ/cycle)

Cycle 202 GMT 19/ 9/2020 18:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 31 13.86 530 228 0.23 / 1080.38 3 3
2 12 1114.12 50 6.80 1849 629 0.86 / 1081.01 3 3
3 7 1120.52 21 10.74 1971 445 1.30 / 1081.45 3 3
4 13 1063.00 37 12.45 1915 882 2.18 / 1082.33 3 3
5 13 852.76 37 12.94 1597 765 2.95 / 1083.10 3 3
6 13 26.20 37 14.00 412 213 3.16 / 1083.31 3 3
7 8 0.24 190 13.98 370 983 4.14 / 1084.29 3 14
Average= 5.34 (KJ/cycle)

Cycle 201 GMT 9/ 9/2020 23:59: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 31 13.86 526 226 0.23 / 1076.59 3 3
2 12 1111.92 50 7.01 1850 648 0.87 / 1077.24 3 3
3 7 1118.20 21 10.83 1966 447 1.32 / 1077.69 3 3
4 13 1047.56 37 12.52 1883 872 2.19 / 1078.56 3 3
5 13 635.36 37 13.26 1275 626 2.82 / 1079.18 3 3
6 8 -0.04 190 13.98 364 967 3.79 / 1080.15 3 9
Average= 5.35 (KJ/cycle)

Cycle 200 GMT 31/ 8/2020 5:30: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 33 13.87 534 244 0.24 / 1072.82 3 3
2 3 947.00 -1 13.87 534 0 0.00 / 1072.82 3 3
3 3 1013.64 1 11.89 1862 22 0.27 / 1072.85 3 3
4 12 1116.68 50 8.26 1913 790 1.06 / 1073.64 3 3
5 7 1121.92 21 11.13 1976 462 1.52 / 1074.10 3 3
6 13 1000.52 37 12.74 1807 852 2.37 / 1074.95 3 3
7 13 341.80 37 13.64 850 429 2.80 / 1075.38 3 3
8 8 0.32 190 13.97 371 985 3.78 / 1076.36 3 12
Average= 5.36 (KJ/cycle)

Cycle 199 GMT 21/ 8/2020 11: 6: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 31 13.85 541 232 0.23 / 1067.46 3 3
2 12 1111.16 6 11.76 2013 142 0.37 / 1067.60 3 3
3 12 1975.04 50 9.71 3199 1553 1.93 / 1069.15 3 3
4 7 1970.72 21 10.43 3234 708 2.64 / 1069.86 3 3
5 13 1524.40 37 12.26 2551 1157 3.79 / 1071.02 3 3
6 13 563.88 37 13.41 1158 575 4.37 / 1071.59 3 3
7 8 0.04 190 14.01 371 988 5.36 / 1072.58 3 11
Average= 5.36 (KJ/cycle)

Cycle 198 GMT 20/ 8/2020 6:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 31 13.82 539 231 0.23 / 1063.69 3 3
2 12 1102.20 50 6.93 1843 639 0.87 / 1064.33 3 3
3 7 1109.32 21 10.77 1958 443 1.31 / 1064.77 3 3
4 13 1047.72 37 12.48 1878 867 2.18 / 1065.64 3 3
5 13 624.76 37 13.25 1255 615 2.79 / 1066.25 3 3
6 8 0.40 190 13.97 367 974 3.77 / 1067.23 3 8
Average= 5.36 (KJ/cycle)

Cycle 197 GMT 10/ 8/2020 12:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 31 13.82 544 233 0.23 / 1059.51 3 3
2 3 1037.52 1 12.29 1909 23 0.26 / 1059.54 3 3
3 12 1130.56 50 6.92 1897 656 0.91 / 1060.19 3 3
4 7 1137.04 21 10.79 1987 450 1.36 / 1060.64 3 3
5 13 1068.52 37 12.52 1907 883 2.25 / 1061.53 3 3
6 13 849.60 37 12.96 1582 759 3.01 / 1062.29 3 3
7 13 6.24 37 14.02 385 200 3.20 / 1062.49 3 3
8 8 -0.16 190 13.99 365 970 4.18 / 1063.46 3 9
Average= 5.37 (KJ/cycle)

Cycle 196 GMT 31/ 7/2020 17:47: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 31 13.87 533 229 0.23 / 1055.62 3 3
2 12 1128.32 50 8.02 1925 772 1.00 / 1056.40 3 3
3 7 1135.00 21 11.00 2026 468 1.47 / 1056.86 3 3
4 13 1022.24 37 12.61 1859 867 2.34 / 1057.73 3 3
5 13 566.28 37 13.33 1172 578 2.91 / 1058.31 3 3
6 8 -0.12 190 13.99 366 973 3.89 / 1059.28 3 11
Average= 5.38 (KJ/cycle)

Cycle 195 GMT 21/ 7/2020 23:30: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 31 13.82 542 232 0.23 / 1050.28 3 3
2 12 1122.08 6 11.87 1987 142 0.37 / 1050.42 3 3
3 12 1989.44 50 9.64 3210 1547 1.92 / 1051.97 3 3
4 7 1984.40 21 10.40 3244 708 2.63 / 1052.68 3 3
5 13 1544.76 37 12.18 2600 1172 3.80 / 1053.85 3 3
6 13 579.64 37 13.39 1170 580 4.38 / 1054.43 3 3
7 8 0.16 190 14.03 362 965 5.35 / 1055.39 3 9
Average= 5.38 (KJ/cycle)

Cycle 194 GMT 20/ 7/2020 19:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 31 13.84 537 230 0.23 / 1046.35 3 3
2 12 1126.76 50 6.47 1869 605 0.84 / 1046.95 3 3
3 7 1133.84 21 10.50 1984 437 1.27 / 1047.39 3 3
4 13 1105.80 37 12.24 2000 906 2.18 / 1048.30 3 3
5 13 892.92 37 12.82 1650 783 2.96 / 1049.08 3 3
6 8 0.48 190 13.97 365 969 3.93 / 1050.05 3 10
Average= 5.38 (KJ/cycle)

Cycle 193 GMT 11/ 7/2020 0:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 31 13.82 541 232 0.23 / 1042.21 3 3
2 12 1121.76 50 6.44 1867 601 0.83 / 1042.81 3 3
3 7 1128.64 21 10.33 1999 434 1.27 / 1043.24 3 3
4 13 1096.56 37 12.16 1989 895 2.16 / 1044.14 3 3
5 13 886.44 37 12.75 1676 791 2.95 / 1044.93 3 3
6 13 30.20 37 13.97 417 216 3.17 / 1045.14 3 3
7 8 -0.28 190 13.99 367 976 4.14 / 1046.12 3 14
Average= 5.39 (KJ/cycle)

Cycle 192 GMT 1/ 7/2020 6:18: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 31 13.88 526 226 0.23 / 1038.40 3 3
2 12 1114.36 50 7.76 1892 734 0.96 / 1039.13 3 3
3 7 1120.60 21 10.85 2000 456 1.42 / 1039.58 3 3
4 13 1025.20 36 12.45 1883 844 2.26 / 1040.43 3 3
5 13 587.84 36 13.26 1213 579 2.84 / 1041.01 3 3
6 8 0.40 190 13.99 364 968 3.81 / 1041.98 3 12
Average= 5.40 (KJ/cycle)

Cycle 191 GMT 21/ 6/2020 11:54: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 31 13.87 521 224 0.22 / 1032.90 3 3
2 12 1111.80 6 11.37 2009 137 0.36 / 1033.04 3 3
3 12 1997.04 50 9.19 3216 1478 1.84 / 1034.52 3 3
4 7 1992.52 21 10.23 3252 699 2.54 / 1035.22 3 3
5 13 1773.68 36 11.81 2965 1261 3.80 / 1036.48 3 3
6 13 790.64 36 13.14 1487 703 4.50 / 1037.18 3 3
7 8 0.24 190 14.03 371 989 5.49 / 1038.17 3 10
Average= 5.41 (KJ/cycle)

Cycle 190 GMT 20/ 6/2020 7:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 31 13.87 532 229 0.23 / 1028.90 3 3
2 12 1107.56 50 6.42 1849 594 0.82 / 1029.49 3 3
3 7 1114.56 21 10.10 1965 417 1.24 / 1029.91 3 3
4 13 1099.40 36 11.91 1988 852 2.09 / 1030.76 3 3
5 13 889.52 36 12.66 1650 752 2.84 / 1031.51 3 3
6 13 5.44 36 14.00 379 191 3.03 / 1031.70 3 3
7 8 0.00 190 13.97 368 977 4.01 / 1032.68 3 14
Average= 5.41 (KJ/cycle)

Cycle 189 GMT 10/ 6/2020 13: 7: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 31 13.83 536 230 0.23 / 1024.85 3 3
2 12 1118.04 50 6.28 1865 586 0.82 / 1025.44 3 3
3 7 1124.56 21 9.81 1990 410 1.23 / 1025.85 3 3
4 13 1136.60 36 11.73 2050 866 2.09 / 1026.71 3 3
5 13 932.56 36 12.63 1705 775 2.87 / 1027.49 3 3
6 13 15.44 36 13.99 395 199 3.07 / 1027.69 3 3
7 8 -0.08 190 13.97 370 982 4.05 / 1028.67 3 13
Average= 5.41 (KJ/cycle)

Cycle 188 GMT 31/ 5/2020 18:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 31 13.94 544 235 0.24 / 1021.08 3 3
2 12 1107.16 50 7.50 1878 704 0.94 / 1021.79 3 3
3 7 1114.24 21 10.47 1963 432 1.37 / 1022.22 3 3
4 13 1032.56 36 12.16 1891 828 2.20 / 1023.05 3 3
5 13 610.48 36 13.20 1247 593 2.79 / 1023.64 3 3
6 8 0.20 190 13.99 369 981 3.77 / 1024.62 3 16
Average= 5.42 (KJ/cycle)

Cycle 187 GMT 21/ 5/2020 23:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 28 13.93 536 209 0.21 / 1015.56 3 3
2 10 1012.52 4 12.70 1860 94 0.30 / 1015.66 3 3
3 12 1095.40 5 11.48 1997 115 0.42 / 1015.77 3 3
4 12 2001.72 50 9.78 3251 1590 2.01 / 1017.36 3 3
5 7 1997.84 21 10.48 3259 717 2.73 / 1018.08 3 3
6 13 1559.96 36 12.39 2647 1181 3.91 / 1019.26 3 3
7 13 601.20 36 13.43 1213 586 4.49 / 1019.85 3 3
8 8 0.12 190 14.07 374 1000 5.49 / 1020.85 3 11
Average= 5.43 (KJ/cycle)

Cycle 186 GMT 20/ 5/2020 20:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 31 13.94 524 226 0.23 / 1008.38 3 3
2 12 1105.88 14 6.80 1859 177 0.40 / 1008.56 3 3
3 12 1982.96 65 5.00 2643 859 1.26 / 1009.41 3 3
4 12 1983.12 90 5.36 2981 1438 2.70 / 1010.85 3 3
5 7 1980.20 21 9.73 3221 658 3.36 / 1011.51 3 3
6 13 1840.32 36 11.69 3054 1285 4.64 / 1012.80 3 3
7 13 1407.96 36 12.55 2402 1085 5.73 / 1013.88 3 3
8 13 453.60 36 13.56 1006 491 6.22 / 1014.37 3 3
9 8 0.28 190 14.07 368 984 7.20 / 1015.36 3 8
Average= 5.43 (KJ/cycle)

Cycle 185 GMT 10/ 5/2020 18:36: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 31 13.94 537 232 0.23 / 1000.98 3 3
2 12 1117.40 14 6.62 1885 175 0.41 / 1001.15 3 3
3 12 1983.84 100 4.99 2667 1331 1.74 / 1002.49 3 3
4 12 1984.00 65 5.69 3111 1151 2.89 / 1003.64 3 3
5 7 1981.12 21 9.65 3231 655 3.54 / 1004.29 3 3
6 13 1838.08 36 11.76 3050 1291 4.83 / 1005.58 3 3
7 13 1398.88 36 12.60 2392 1085 5.92 / 1006.67 3 3
8 13 458.48 36 13.57 1019 498 6.42 / 1007.16 3 3
9 8 -0.08 190 14.08 369 987 7.40 / 1008.15 3 12
Average= 5.42 (KJ/cycle)

Cycle 184 GMT 30/ 4/2020 16:54: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 31 13.96 524 227 0.23 / 993.57 3 3
2 12 1114.76 14 6.80 1872 178 0.40 / 993.74 3 3
3 12 1993.88 100 4.99 2671 1333 1.74 / 995.08 3 3
4 12 1994.64 65 5.68 3116 1150 2.89 / 996.23 3 3
5 7 1992.48 21 9.66 3233 656 3.54 / 996.88 3 3
6 13 1851.24 36 11.78 3057 1296 4.84 / 998.18 3 3
7 13 1417.16 36 12.59 2414 1094 5.93 / 999.27 3 3
8 13 443.12 36 13.57 997 487 6.42 / 999.76 3 3
9 8 0.16 190 14.08 369 987 7.41 / 1000.75 3 14
Average= 5.41 (KJ/cycle)

Cycle 183 GMT 20/ 4/2020 15: 3: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 31 13.97 526 228 0.23 / 986.21 3 3
2 12 1104.24 14 6.89 1844 178 0.41 / 986.39 3 3
3 12 1976.64 100 5.00 2698 1349 1.75 / 987.73 3 3
4 12 1976.56 65 5.80 3127 1179 2.93 / 988.91 3 3
5 7 1973.48 21 9.75 3208 657 3.59 / 989.57 3 3
6 13 1817.40 36 11.86 3018 1289 4.88 / 990.86 3 3
7 13 1361.68 36 12.69 2332 1065 5.94 / 991.92 3 3
8 13 382.44 36 13.64 911 447 6.39 / 992.37 3 3
9 8 0.36 190 14.10 361 967 7.36 / 993.34 3 14
Average= 5.40 (KJ/cycle)

Cycle 182 GMT 10/ 4/2020 13:31: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 31 13.97 531 230 0.23 / 978.81 3 3
2 12 1114.68 14 6.52 1882 172 0.40 / 978.98 3 3
3 12 1977.60 100 5.00 2691 1345 1.75 / 980.33 3 3
4 12 1977.40 65 5.79 3132 1179 2.93 / 981.51 3 3
5 7 1973.96 21 9.74 3208 656 3.58 / 982.16 3 3
6 13 1820.08 36 11.92 3026 1299 4.88 / 983.46 3 3
7 13 1367.56 36 12.72 2360 1081 5.96 / 984.54 3 3
8 13 386.44 36 13.64 913 448 6.41 / 984.99 3 3
9 8 -0.04 190 14.09 370 991 7.40 / 985.98 3 4
Average= 5.39 (KJ/cycle)

Cycle 181 GMT 31/ 3/2020 11:58: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 31 13.99 539 234 0.23 / 971.30 3 3
2 12 1120.44 14 6.75 1888 178 0.41 / 971.47 3 3
3 12 1981.88 90 5.00 2713 1221 1.63 / 972.70 3 3
4 12 1981.92 65 5.79 3108 1170 2.80 / 973.87 3 3
5 7 1978.84 21 9.77 3196 656 3.46 / 974.52 3 3
6 13 1816.96 36 11.93 3012 1294 4.75 / 975.81 3 3
7 13 1598.28 36 12.49 2702 1215 5.97 / 977.03 3 3
8 13 563.08 36 13.50 1163 565 6.53 / 977.59 3 3
9 8 0.24 190 14.09 368 985 7.52 / 978.58 3 6
Average= 5.38 (KJ/cycle)

Cycle 180 GMT 21/ 3/2020 10:33: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 31 14.01 522 227 0.23 / 964.01 3 3
2 12 1110.64 14 6.70 1853 174 0.40 / 964.18 3 3
3 12 1973.24 90 5.00 2719 1224 1.62 / 965.40 3 3
4 12 1972.64 65 5.79 3126 1176 2.80 / 966.58 3 3
5 7 1969.00 21 9.80 3210 661 3.46 / 967.24 3 3
6 13 1813.64 36 11.97 3022 1302 4.76 / 968.54 3 3
7 13 1367.36 36 12.73 2350 1077 5.84 / 969.62 3 3
8 13 382.44 36 13.65 916 450 6.29 / 970.07 3 3
9 8 -0.04 190 14.09 371 993 7.28 / 971.06 3 14
Average= 5.36 (KJ/cycle)

Cycle 179 GMT 11/ 3/2020 9: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 31 13.99 534 232 0.23 / 956.69 3 3
2 12 1115.12 14 6.59 1882 174 0.41 / 956.86 3 3
3 12 1971.80 90 5.01 2757 1243 1.65 / 958.10 3 3
4 12 1971.60 65 5.89 3152 1207 2.86 / 959.31 3 3
5 7 1968.00 21 9.84 3187 659 3.51 / 959.97 3 3
6 13 1804.76 36 12.04 2999 1300 4.81 / 961.27 3 3
7 13 1359.56 36 12.77 2321 1067 5.88 / 962.34 3 3
8 13 368.28 36 13.67 901 443 6.32 / 962.78 3 3
9 8 0.12 190 14.09 373 999 7.32 / 963.78 3 12
Average= 5.35 (KJ/cycle)

Cycle 178 GMT 1/ 3/2020 7:31: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 31 13.98 520 225 0.23 / 949.33 3 3
2 12 1105.92 14 6.79 1839 175 0.40 / 949.51 3 3
3 12 1963.36 90 5.02 2794 1262 1.66 / 950.77 3 3
4 12 1963.32 65 6.01 3175 1240 2.90 / 952.01 3 3
5 7 1959.48 21 9.95 3181 665 3.57 / 952.67 3 3
6 13 1795.72 36 12.07 3014 1310 4.88 / 953.98 3 3
7 13 1341.08 36 12.81 2285 1054 5.93 / 955.04 3 3
8 13 355.56 36 13.68 877 432 6.36 / 955.47 3 3
9 8 0.04 190 14.10 368 986 7.35 / 956.46 3 14
Average= 5.34 (KJ/cycle)

Cycle 177 GMT 20/ 2/2020 6: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 31 14.01 526 228 0.23 / 942.10 3 3
2 12 1108.20 14 6.76 1857 176 0.40 / 942.28 3 3
3 12 1965.64 90 5.02 2773 1253 1.66 / 943.53 3 3
4 12 1965.92 65 5.96 3164 1226 2.88 / 944.75 3 3
5 7 1962.64 21 9.94 3184 665 3.55 / 945.42 3 3
6 13 1807.68 36 12.12 3012 1314 4.86 / 946.73 3 3
7 13 1131.12 36 12.99 1990 931 5.79 / 947.66 3 3
8 13 391.88 36 13.67 925 455 6.25 / 948.12 3 3
9 8 0.24 190 14.09 369 988 7.24 / 949.11 3 11
Average= 5.33 (KJ/cycle)

Cycle 176 GMT 10/ 2/2020 4:30: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 31 14.00 531 230 0.23 / 935.30 3 3
2 12 1101.36 14 6.80 1860 177 0.41 / 935.48 3 3
3 12 1969.36 65 5.04 2815 922 1.33 / 936.40 3 3
4 12 1969.92 65 5.90 3129 1200 2.53 / 937.60 3 3
5 7 1967.24 21 9.92 3195 666 3.20 / 938.27 3 3
6 13 1815.44 36 12.06 3036 1318 4.51 / 939.59 3 3
7 13 1163.36 36 12.95 2046 954 5.47 / 940.54 3 3
8 13 225.20 36 13.81 689 343 5.81 / 940.88 3 3
9 8 0.16 190 14.09 370 991 6.80 / 941.87 3 13
Average= 5.32 (KJ/cycle)

Cycle 175 GMT 31/ 1/2020 2:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 31 14.00 526 228 0.23 / 928.28 3 3
2 12 1115.80 14 6.91 1880 182 0.41 / 928.46 3 3
3 12 1987.40 65 5.05 2864 940 1.35 / 929.40 3 3
4 12 1987.36 65 6.01 3180 1242 2.59 / 930.64 3 3
5 7 1983.84 21 9.99 3219 675 3.27 / 931.32 3 3
6 13 1814.76 36 12.14 3019 1319 4.59 / 932.64 3 3
7 13 1144.40 36 12.99 2003 937 5.52 / 933.57 3 3
8 13 208.80 36 13.84 666 332 5.86 / 933.91 3 3
9 13 1.48 36 14.15 374 191 6.05 / 934.10 3 3
10 8 0.04 190 14.11 364 976 7.02 / 935.07 3 20
Average= 5.31 (KJ/cycle)

Cycle 174 GMT 21/ 1/2020 0:53: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 31 14.03 518 225 0.23 / 921.13 3 3
2 12 1115.32 14 6.90 1893 183 0.41 / 921.31 3 3
3 12 1975.68 65 5.06 2936 966 1.37 / 922.28 3 3
4 12 1975.64 65 6.16 3204 1283 2.66 / 923.56 3 3
5 7 1971.52 21 10.05 3215 679 3.34 / 924.24 3 3
6 13 1805.68 36 12.17 3029 1327 4.66 / 925.56 3 3
7 13 1335.84 36 12.80 2343 1080 5.74 / 926.64 3 3
8 13 338.04 36 13.73 856 423 6.17 / 927.07 3 3
9 8 0.16 190 14.10 367 983 7.15 / 928.05 3 13
Average= 5.30 (KJ/cycle)

Cycle 173 GMT 10/ 1/2020 23:26: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 30 13.99 532 223 0.22 / 914.51 3 3
2 3 1026.88 1 11.85 1897 22 0.25 / 914.54 3 3
3 12 1126.72 14 7.00 1899 186 0.43 / 914.72 3 3
4 12 1983.32 55 5.11 2990 840 1.27 / 915.56 3 3
5 12 1983.48 55 6.44 3184 1128 2.40 / 916.69 3 3
6 7 1980.28 21 10.02 3215 677 3.08 / 917.37 3 3
7 13 1801.72 36 12.19 2994 1314 4.39 / 918.68 3 3
8 13 1131.04 36 13.00 1984 929 5.32 / 919.61 3 3
9 13 163.20 36 13.90 609 305 5.62 / 919.91 3 3
10 8 -0.08 190 14.09 369 988 6.61 / 920.90 3 12
Average= 5.29 (KJ/cycle)

Cycle 172 GMT 31/12/2019 21:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 32 13.99 523 234 0.23 / 907.64 3 3
2 3 971.68 -1 13.99 523 0 0.00 / 907.64 3 3
3 12 1156.72 14 7.17 1960 197 0.43 / 907.83 3 3
4 12 2011.12 55 5.11 3111 874 1.31 / 908.71 3 3
5 12 2012.44 55 6.56 3235 1167 2.47 / 909.88 3 3
6 7 2010.64 21 10.04 3257 687 3.16 / 910.56 3 3
7 13 1855.84 36 12.10 3070 1337 4.50 / 911.90 3 3
8 13 1372.20 36 12.77 2340 1076 5.57 / 912.98 3 3
9 13 180.80 36 13.88 638 319 5.89 / 913.29 3 3
10 8 0.28 190 14.08 372 995 6.89 / 914.29 3 9
Average= 5.28 (KJ/cycle)

Cycle 171 GMT 21/12/2019 20:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 33 13.99 521 241 0.24 / 900.85 3 3
2 3 958.68 -1 13.99 521 0 0.00 / 900.85 3 3
3 3 1024.28 1 11.74 1879 22 0.26 / 900.87 3 3
4 12 1133.48 14 7.60 1925 205 0.47 / 901.08 3 3
5 12 2004.28 55 5.17 3245 923 1.39 / 902.00 3 3
6 12 2004.56 55 7.60 3165 1323 2.71 / 903.32 3 3
7 7 2000.64 21 10.16 3233 690 3.40 / 904.01 3 3
8 13 1801.08 36 12.22 2993 1317 4.72 / 905.33 3 3
9 13 1088.84 36 13.04 1916 899 5.62 / 906.23 3 3
10 13 18.12 36 14.09 401 203 5.82 / 906.43 3 3
11 8 -0.04 190 14.10 362 970 6.79 / 907.40 3 8
Average= 5.28 (KJ/cycle)

Cycle 170 GMT 11/12/2019 19:31:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 32 14.00 535 240 0.24 / 894.06 3 3
2 3 1016.28 1 11.85 1860 22 0.26 / 894.09 3 3
3 12 1129.36 14 7.65 1920 206 0.47 / 894.29 3 3
4 12 2000.28 55 5.16 3270 928 1.40 / 895.22 3 3
5 12 2001.08 55 7.60 3179 1329 2.72 / 896.55 3 3
6 7 1997.36 21 10.17 3231 690 3.41 / 897.24 3 3
7 13 1780.96 36 12.30 2950 1306 4.72 / 898.54 3 3
8 13 1048.48 36 13.10 1846 871 5.59 / 899.42 3 3
9 13 59.60 36 14.05 457 231 5.82 / 899.65 3 3
10 8 0.16 190 14.11 360 965 6.79 / 900.61 3 10
Average= 5.27 (KJ/cycle)

Cycle 169 GMT 1/12/2019 19: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 32 14.01 527 236 0.24 / 887.61 3 3
2 12 1135.64 12 7.25 1916 167 0.40 / 887.78 3 3
3 12 2001.24 50 5.62 3178 893 1.30 / 888.67 3 3
4 12 2002.32 45 7.64 3154 1084 2.38 / 889.76 3 3
5 7 1998.36 21 10.10 3222 683 3.06 / 890.44 3 3
6 13 1789.96 36 12.26 2958 1306 4.37 / 891.75 3 3
7 13 1051.16 36 13.09 1837 866 5.23 / 892.61 3 3
8 13 65.04 36 14.03 471 238 5.47 / 892.85 3 3
9 8 0.28 190 14.11 363 973 6.45 / 893.82 3 15
Average= 5.26 (KJ/cycle)

Cycle 168 GMT 21/11/2019 19:15:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 33 13.98 550 254 0.25 / 881.02 3 3
2 3 957.72 -1 13.98 550 0 0.00 / 881.02 3 3
3 3 1021.68 1 11.84 1885 22 0.28 / 881.04 3 3
4 12 1136.28 12 7.28 1906 167 0.44 / 881.21 3 3
5 12 2004.44 50 5.15 3241 835 1.28 / 882.04 3 3
6 12 2006.08 45 7.64 3190 1097 2.37 / 883.14 3 3
7 7 2004.68 21 10.12 3239 688 3.06 / 883.83 3 3
8 13 1830.56 36 12.22 3038 1336 4.40 / 885.17 3 3
9 13 1135.72 36 13.00 1991 932 5.33 / 886.10 3 3
10 13 147.52 36 13.95 583 293 5.62 / 886.39 3 3
11 8 -0.08 190 14.09 369 988 6.61 / 887.38 3 12
Average= 5.25 (KJ/cycle)

Cycle 167 GMT 11/11/2019 19:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 33 14.02 534 247 0.25 / 874.48 3 3
2 12 1101.24 12 7.41 1868 166 0.41 / 874.65 3 3
3 12 2005.24 50 5.61 3184 893 1.31 / 875.54 3 3
4 12 2006.52 45 7.71 3177 1102 2.41 / 876.64 3 3
5 7 2002.88 21 10.18 3235 692 3.10 / 877.33 3 3
6 13 1801.80 36 12.23 2997 1320 4.42 / 878.65 3 3
7 13 1066.64 36 13.06 1884 886 5.31 / 879.54 3 3
8 13 61.12 36 14.06 466 236 5.54 / 879.77 3 3
9 8 0.60 190 14.08 371 992 6.53 / 880.77 3 9
Average= 5.24 (KJ/cycle)

Cycle 166 GMT 1/11/2019 19:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 33 14.02 544 252 0.25 / 868.38 3 3
2 12 1102.20 12 7.69 1862 172 0.42 / 868.55 3 3
3 12 2001.64 50 5.67 3182 902 1.33 / 869.45 3 3
4 12 2002.84 45 7.77 3181 1112 2.44 / 870.56 3 3
5 7 1999.08 21 10.24 3255 700 3.14 / 871.26 3 3
6 13 1586.08 36 12.56 2666 1205 4.34 / 872.47 3 3
7 13 883.84 36 13.23 1623 773 5.12 / 873.24 3 3
8 8 0.08 190 14.07 371 992 6.11 / 874.23 3 5
Average= 5.23 (KJ/cycle)

Cycle 165 GMT 22/10/2019 19:38: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 33 14.02 524 242 0.24 / 862.19 3 3
2 12 1118.00 8 7.24 1895 110 0.35 / 862.30 3 3
3 12 2001.76 50 6.15 3140 966 1.32 / 863.26 3 3
4 12 2003.24 30 8.75 3205 841 2.16 / 864.11 3 3
5 7 2000.44 21 10.27 3238 698 2.86 / 864.80 3 3
6 13 1809.60 36 12.27 3017 1333 4.19 / 866.14 3 3
7 13 874.20 36 13.26 1605 766 4.96 / 866.90 3 3
8 13 73.24 36 14.05 481 243 5.20 / 867.15 3 3
9 8 -0.12 190 14.09 366 980 6.18 / 868.13 3 14
Average= 5.23 (KJ/cycle)

Cycle 164 GMT 12/10/2019 19:48:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 33 14.03 534 247 0.25 / 855.89 3 3
2 12 1112.92 8 5.88 1843 87 0.33 / 855.98 3 3
3 12 2004.72 50 5.07 2929 743 1.08 / 856.72 3 3
4 12 2007.08 30 7.94 3197 762 1.84 / 857.48 3 3
5 7 2007.60 21 10.13 3251 692 2.53 / 858.17 3 3
6 13 1837.64 36 12.37 3063 1364 3.89 / 859.54 3 3
7 13 1361.88 36 12.88 2337 1084 4.98 / 860.62 3 3
8 13 195.48 36 13.91 654 327 5.30 / 860.95 3 3
9 8 0.16 190 14.08 373 998 6.30 / 861.95 3 10
Average= 5.22 (KJ/cycle)

Cycle 163 GMT 2/10/2019 20: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 33 14.06 538 250 0.25 / 849.73 3 3
2 3 970.04 -1 14.06 538 0 0.00 / 849.73 3 3
3 3 1038.60 1 12.31 1899 23 0.27 / 849.75 3 3
4 12 1146.24 3 4.88 1766 26 0.30 / 849.78 3 3
5 12 2008.12 45 5.03 2697 610 0.91 / 850.39 3 3
6 7 2011.44 21 9.78 3243 666 1.58 / 851.06 3 3
7 13 1936.92 36 12.18 3169 1390 2.96 / 852.45 3 3
8 13 1736.04 36 12.52 2888 1302 4.27 / 853.75 3 3
9 13 777.52 36 13.39 1463 705 4.97 / 854.45 3 3
10 13 24.76 36 14.14 409 208 5.18 / 854.66 3 3
11 8 0.44 190 14.08 367 982 6.16 / 855.64 3 17
Average= 5.22 (KJ/cycle)

Cycle 162 GMT 22/ 9/2019 20:16: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 32 14.07 532 240 0.24 / 843.75 3 3
2 3 1036.72 1 12.45 1932 24 0.26 / 843.77 3 3
3 3 1021.36 1 11.65 1904 22 0.29 / 843.79 3 3
4 12 1130.56 3 4.89 1763 26 0.31 / 843.82 3 3
5 12 2004.40 45 5.04 2762 626 0.94 / 844.45 3 3
6 7 2008.48 21 10.00 3252 683 1.62 / 845.13 3 3
7 13 1928.16 36 12.19 3170 1391 3.01 / 846.52 3 3
8 13 1714.88 36 12.54 2872 1297 4.31 / 847.82 3 3
9 13 738.32 36 13.42 1408 680 4.99 / 848.50 3 3
10 8 -0.08 190 14.08 368 984 5.97 / 849.48 3 7
Average= 5.21 (KJ/cycle)

Cycle 161 GMT 12/ 9/2019 20:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 32 14.08 532 240 0.24 / 837.85 3 3
2 12 1114.48 3 4.89 1774 26 0.27 / 837.87 3 3
3 12 2002.36 45 5.04 2730 619 0.88 / 838.49 3 3
4 7 2005.36 21 9.91 3239 674 1.56 / 839.16 3 3
5 13 1917.88 36 12.19 3166 1389 2.95 / 840.55 3 3
6 13 1705.80 36 12.56 2829 1279 4.23 / 841.83 3 3
7 13 745.44 36 13.43 1412 683 4.91 / 842.52 3 3
8 8 -0.24 190 14.08 371 992 5.90 / 843.51 3 7
Average= 5.21 (KJ/cycle)

Cycle 160 GMT 2/ 9/2019 20:37: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 31 14.06 524 228 0.23 / 831.70 3 3
2 12 1124.00 3 4.89 1772 26 0.25 / 831.72 3 3
3 12 2003.60 45 5.05 2787 633 0.89 / 832.36 3 3
4 7 2006.64 21 10.02 3251 684 1.57 / 833.04 3 3
5 13 1922.56 36 12.21 3154 1386 2.96 / 834.43 3 3
6 13 1712.52 36 12.58 2797 1267 4.22 / 835.69 3 3
7 13 760.20 36 13.41 1440 695 4.92 / 836.39 3 3
8 13 47.32 36 14.12 447 227 5.15 / 836.62 3 3
9 8 0.60 190 14.10 369 989 6.14 / 837.61 3 12
Average= 5.20 (KJ/cycle)

Cycle 159 GMT 23/ 8/2019 20:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 31 14.07 521 227 0.23 / 825.75 3 3
2 12 1120.96 3 4.89 1780 26 0.25 / 825.78 3 3
3 12 2000.32 45 5.28 2882 685 0.94 / 826.46 3 3
4 7 2002.36 21 10.28 3253 702 1.64 / 827.16 3 3
5 13 1896.48 36 12.23 3146 1385 3.03 / 828.55 3 3
6 13 1689.56 36 12.57 2828 1280 4.31 / 829.83 3 3
7 13 698.32 36 13.49 1350 656 4.96 / 830.48 3 3
8 8 -0.16 190 14.09 368 985 5.95 / 831.47 3 6
Average= 5.20 (KJ/cycle)

Cycle 158 GMT 13/ 8/2019 21: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 31 14.06 544 237 0.24 / 820.03 3 3
2 12 1125.24 3 4.89 1786 26 0.26 / 820.06 3 3
3 12 2004.00 45 5.53 2932 730 0.99 / 820.79 3 3
4 7 2005.68 21 10.34 3262 708 1.70 / 821.50 3 3
5 13 1883.24 36 12.25 3099 1367 3.07 / 822.86 3 3
6 13 1455.56 36 12.83 2427 1121 4.19 / 823.99 3 3
7 13 537.40 36 13.63 1122 551 4.74 / 824.54 3 3
8 8 0.52 190 14.09 369 988 5.73 / 825.52 3 7
Average= 5.19 (KJ/cycle)

Cycle 157 GMT 3/ 8/2019 21: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 31 14.09 524 229 0.23 / 814.34 3 3
2 12 1114.96 3 4.89 1781 26 0.26 / 814.37 3 3
3 12 2001.40 45 5.81 2916 762 1.02 / 815.13 3 3
4 7 2003.80 21 10.43 3240 710 1.73 / 815.84 3 3
5 13 1877.76 36 12.29 3072 1359 3.09 / 817.20 3 3
6 13 1447.24 36 12.82 2416 1115 4.20 / 818.31 3 3
7 13 486.28 36 13.68 1039 512 4.71 / 818.83 3 3
8 8 0.20 190 14.11 362 970 5.68 / 819.80 3 11
Average= 5.19 (KJ/cycle)

Cycle 156 GMT 24/ 7/2019 21:14: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 31 14.11 534 234 0.23 / 808.60 3 3
2 12 1114.12 3 4.89 1793 26 0.26 / 808.63 3 3
3 12 2004.20 45 6.21 2985 834 1.09 / 809.47 3 3
4 7 2006.04 21 10.50 3255 718 1.81 / 810.18 3 3
5 13 1859.92 36 12.28 3082 1362 3.17 / 811.55 3 3
6 13 1409.32 36 12.84 2389 1104 4.28 / 812.65 3 3
7 13 434.00 36 13.73 977 483 4.76 / 813.13 3 3
8 8 -0.16 190 14.10 366 981 5.74 / 814.11 3 11
Average= 5.19 (KJ/cycle)

Cycle 155 GMT 14/ 7/2019 21:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 31 14.08 528 230 0.23 / 802.88 3 3
2 12 1119.32 3 4.89 1793 26 0.26 / 802.91 3 3
3 12 2001.56 45 6.37 2978 854 1.11 / 803.76 3 3
4 7 2003.36 21 10.52 3240 716 1.83 / 804.47 3 3
5 13 1855.32 36 12.31 3073 1362 3.19 / 805.84 3 3
6 13 1399.72 36 12.87 2358 1093 4.28 / 806.93 3 3
7 13 411.00 36 13.75 942 466 4.75 / 807.40 3 3
8 8 0.16 190 14.11 364 976 5.72 / 808.37 3 7
Average= 5.18 (KJ/cycle)

Cycle 154 GMT 4/ 7/2019 21:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 31 14.11 541 237 0.24 / 797.07 3 3
2 12 1118.96 3 4.90 1833 27 0.26 / 797.10 3 3
3 12 2001.80 45 6.89 3019 936 1.20 / 798.03 3 3
4 7 2003.08 21 10.58 3247 721 1.92 / 798.75 3 3
5 13 1842.56 36 12.31 3075 1363 3.28 / 800.12 3 3
6 13 1397.92 36 12.84 2392 1106 4.39 / 801.22 3 3
7 13 375.92 36 13.79 900 447 4.84 / 801.67 3 3
8 8 0.20 190 14.12 365 979 5.82 / 802.65 3 13
Average= 5.18 (KJ/cycle)

Cycle 153 GMT 24/ 6/2019 22:23: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 31 14.10 530 232 0.23 / 791.46 3 3
2 12 1108.36 3 4.92 1885 28 0.26 / 791.48 3 3
3 12 2006.36 45 7.26 3070 1003 1.26 / 792.49 3 3
4 7 2007.80 21 10.63 3251 726 1.99 / 793.21 3 3
5 13 1844.92 36 12.29 3075 1361 3.35 / 794.57 3 3
6 13 1155.92 36 13.04 2039 957 4.31 / 795.53 3 3
7 13 199.84 36 13.97 655 329 4.64 / 795.86 3 3
8 8 -0.08 190 14.12 363 974 5.61 / 796.83 3 12
Average= 5.17 (KJ/cycle)

Cycle 152 GMT 14/ 6/2019 22:27: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 31 14.07 528 230 0.23 / 785.89 3 3
2 12 1098.36 3 4.92 1913 28 0.26 / 785.92 3 3
3 12 2002.76 45 7.61 3072 1052 1.31 / 786.97 3 3
4 7 2003.88 21 10.70 3252 731 2.04 / 787.70 3 3
5 13 1842.00 36 12.29 3037 1344 3.38 / 789.05 3 3
6 13 1150.24 36 13.05 2007 943 4.33 / 789.99 3 3
7 13 88.24 36 14.09 500 254 4.58 / 790.24 3 3
8 8 0.64 190 14.12 365 979 5.56 / 791.22 3 7
Average= 5.17 (KJ/cycle)

Cycle 151 GMT 4/ 6/2019 22:39: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 31 14.10 513 224 0.22 / 780.30 3 3
2 12 1122.20 3 5.09 1937 30 0.25 / 780.33 3 3
3 12 2003.00 45 7.91 3097 1102 1.36 / 781.43 3 3
4 7 2003.64 21 10.71 3244 730 2.09 / 782.16 3 3
5 13 1834.48 36 12.31 3038 1346 3.43 / 783.50 3 3
6 13 1141.44 36 13.09 1979 933 4.36 / 784.44 3 3
7 13 78.96 36 14.10 479 243 4.61 / 784.68 3 3
8 8 -0.12 190 14.11 367 984 5.59 / 785.66 3 16
Average= 5.17 (KJ/cycle)

Cycle 150 GMT 25/ 5/2019 22:58: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 32 14.11 514 232 0.23 / 774.65 3 3
2 3 961.24 -1 14.11 514 0 0.00 / 774.65 3 3
3 3 1030.96 1 12.45 1901 24 0.26 / 774.68 3 3
4 12 1139.04 3 5.63 1882 32 0.29 / 774.71 3 3
5 12 2002.92 45 8.29 3130 1168 1.46 / 775.88 3 3
6 7 2003.52 21 10.77 3254 736 2.19 / 776.61 3 3
7 13 1808.60 36 12.35 2993 1331 3.52 / 777.94 3 3
8 13 1106.64 36 13.11 1931 911 4.43 / 778.85 3 3
9 13 79.96 36 14.10 482 245 4.68 / 779.10 3 3
10 8 0.12 190 14.12 363 974 5.65 / 780.07 3 12
Average= 5.17 (KJ/cycle)

Cycle 149 GMT 15/ 5/2019 23:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 32 14.09 538 243 0.24 / 768.95 3 3
2 12 1121.92 3 5.76 1880 32 0.28 / 768.98 3 3
3 12 2002.68 45 8.44 3131 1189 1.46 / 770.17 3 3
4 7 2002.64 21 10.82 3238 736 2.20 / 770.91 3 3
5 13 1813.88 36 12.32 3018 1339 3.54 / 772.25 3 3
6 13 1082.52 36 13.11 1913 903 4.44 / 773.15 3 3
7 13 140.20 36 14.03 572 289 4.73 / 773.44 3 3
8 8 0.04 190 14.11 366 981 5.71 / 774.42 3 14
Average= 5.16 (KJ/cycle)

Cycle 148 GMT 6/ 5/2019 0: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 32 14.08 527 237 0.24 / 763.28 3 3
2 12 1139.32 3 6.24 1891 35 0.27 / 763.32 3 3
3 12 2002.24 45 8.64 3151 1225 1.50 / 764.55 3 3
4 7 2001.76 21 10.85 3247 740 2.24 / 765.29 3 3
5 13 1800.60 36 12.37 2959 1318 3.56 / 766.60 3 3
6 13 1074.84 36 13.12 1870 883 4.44 / 767.49 3 3
7 13 73.80 36 14.10 478 243 4.68 / 767.73 3 3
8 8 0.04 190 14.09 366 980 5.66 / 768.71 3 8
Average= 5.16 (KJ/cycle)

Cycle 147 GMT 26/ 4/2019 0:38: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 31 14.07 519 226 0.23 / 757.76 3 3
2 3 1020.00 1 12.00 1895 23 0.25 / 757.79 3 3
3 12 1127.08 3 6.67 1888 38 0.29 / 757.82 3 3
4 12 2001.20 45 9.11 3146 1290 1.58 / 759.11 3 3
5 7 2000.20 21 10.89 3230 739 2.32 / 759.85 3 3
6 13 1780.72 36 12.40 2916 1302 3.62 / 761.15 3 3
7 13 831.36 36 13.34 1517 729 4.35 / 761.88 3 3
8 13 16.32 36 14.17 391 199 4.54 / 762.08 3 3
9 8 0.16 190 14.10 360 964 5.51 / 763.05 3 11
Average= 5.16 (KJ/cycle)

Cycle 146 GMT 16/ 4/2019 1:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 32 14.08 523 236 0.24 / 752.42 3 3
2 3 938.88 -1 14.08 523 0 0.00 / 752.42 3 3
3 12 1139.48 3 6.96 1925 40 0.28 / 752.46 3 3
4 12 2001.16 45 9.20 3164 1310 1.59 / 753.77 3 3
5 7 1999.80 21 10.89 3238 740 2.33 / 754.51 3 3
6 13 1790.76 36 12.35 2974 1322 3.65 / 755.83 3 3
7 13 837.20 36 13.33 1542 740 4.39 / 756.57 3 3
8 8 0.12 190 14.09 361 966 5.35 / 757.54 3 14
Average= 5.15 (KJ/cycle)

Cycle 145 GMT 6/ 4/2019 1:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 31 14.09 532 232 0.23 / 746.77 3 3
2 3 1044.48 1 12.66 1919 24 0.26 / 746.80 3 3
3 12 1128.44 3 7.20 1907 41 0.30 / 746.84 3 3
4 12 2004.00 45 9.41 3186 1349 1.65 / 748.19 3 3
5 7 2002.92 21 10.90 3249 744 2.39 / 748.93 3 3
6 13 1785.88 36 12.40 2913 1300 3.69 / 750.23 3 3
7 13 828.52 36 13.33 1529 734 4.42 / 750.97 3 3
8 13 67.72 36 14.11 475 241 4.67 / 751.21 3 3
9 8 0.12 190 14.11 364 976 5.64 / 752.18 3 18
Average= 5.15 (KJ/cycle)

Cycle 144 GMT 27/ 3/2019 2: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 31 14.14 522 229 0.23 / 741.37 3 3
2 3 972.60 -1 14.14 522 0 0.00 / 741.37 3 3
3 3 1036.88 1 12.44 1909 24 0.25 / 741.39 3 3
4 12 1153.12 3 7.17 1944 42 0.29 / 741.43 3 3
5 12 2000.36 45 9.43 3177 1348 1.64 / 742.78 3 3
6 7 1999.60 21 10.92 3243 744 2.39 / 743.53 3 3
7 13 1792.36 36 12.37 2949 1313 3.70 / 744.84 3 3
8 13 832.52 36 13.34 1529 734 4.43 / 745.57 3 3
9 8 0.12 190 14.10 361 967 5.40 / 746.54 3 9
Average= 5.15 (KJ/cycle)

Cycle 143 GMT 17/ 3/2019 2:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 31 14.13 524 230 0.23 / 735.74 3 3
2 12 1132.88 3 7.22 1911 41 0.27 / 735.78 3 3
3 12 2003.28 45 9.43 3196 1356 1.63 / 737.14 3 3
4 7 2002.20 21 10.92 3263 748 2.38 / 737.89 3 3
5 13 1786.20 36 12.37 2961 1319 3.69 / 739.20 3 3
6 13 850.84 36 13.32 1563 749 4.44 / 739.95 3 3
7 13 35.52 36 14.16 421 215 4.66 / 740.17 3 3
8 8 -0.08 190 14.10 363 972 5.63 / 741.14 3 16
Average= 5.15 (KJ/cycle)

Cycle 142 GMT 7/ 3/2019 3:11: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 30 14.08 519 219 0.22 / 730.31 3 3
2 3 1024.16 1 12.33 1898 23 0.24 / 730.33 3 3
3 3 1019.68 1 11.62 1915 22 0.26 / 730.36 3 3
4 12 1145.92 3 6.84 1919 39 0.30 / 730.40 3 3
5 12 2002.84 45 9.55 3192 1372 1.68 / 731.77 3 3
6 7 2000.68 21 10.93 3248 746 2.42 / 732.51 3 3
7 13 1784.64 36 12.36 2936 1306 3.73 / 733.82 3 3
8 13 824.68 36 13.35 1520 731 4.46 / 734.55 3 3
9 8 0.12 190 14.11 358 960 5.42 / 735.51 3 11
Average= 5.14 (KJ/cycle)

Cycle 141 GMT 25/ 2/2019 3:34: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 31 14.14 529 232 0.23 / 727.14 3 3
2 3 972.76 -1 14.14 529 0 0.00 / 727.14 3 3
3 12 1055.60 3 8.05 1831 44 0.28 / 727.18 3 3
4 12 1231.64 45 10.61 2144 1024 1.30 / 728.21 3 3
5 7 1227.20 21 11.68 2174 533 1.83 / 728.74 3 3
6 13 300.36 36 13.79 791 393 2.23 / 729.13 3 3
7 8 0.32 190 14.07 359 960 3.19 / 730.09 3 12
Average= 5.14 (KJ/cycle)

Cycle 140 GMT 15/ 2/2019 3:53: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 31 14.13 523 229 0.23 / 721.43 3 3
2 12 1128.76 3 8.40 1955 49 0.28 / 721.48 3 3
3 12 2002.80 45 9.98 3203 1438 1.72 / 722.92 3 3
4 7 2001.24 21 10.93 3270 751 2.47 / 723.67 3 3
5 13 1778.92 36 12.36 2989 1330 3.80 / 725.00 3 3
6 13 786.64 36 13.38 1467 707 4.50 / 725.71 3 3
7 13 50.08 36 14.14 444 226 4.73 / 725.93 3 3
8 8 0.16 190 14.10 363 972 5.70 / 726.91 3 7
Average= 5.16 (KJ/cycle)

Cycle 139 GMT 5/ 2/2019 4:31: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 31 14.07 542 236 0.24 / 716.06 3 3
2 12 1109.36 3 8.57 1917 49 0.29 / 716.11 3 3
3 12 2004.92 45 9.98 3208 1441 1.73 / 717.55 3 3
4 7 2002.64 21 10.95 3276 753 2.48 / 718.30 3 3
5 13 1584.84 36 12.57 2659 1203 3.68 / 719.50 3 3
6 13 850.44 36 13.33 1549 743 4.43 / 720.25 3 3
7 8 0.00 190 14.10 357 956 5.38 / 721.20 3 11
Average= 5.15 (KJ/cycle)

Cycle 138 GMT 26/ 1/2019 4:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 31 14.14 526 231 0.23 / 710.57 3 3
2 12 1100.28 3 8.76 1911 50 0.28 / 710.62 3 3
3 12 2005.72 45 10.07 3202 1451 1.73 / 712.07 3 3
4 7 2003.68 21 10.94 3281 754 2.49 / 712.83 3 3
5 13 1578.68 36 12.57 2658 1203 3.69 / 714.03 3 3
6 13 646.68 36 13.50 1273 619 4.31 / 714.65 3 3
7 13 14.08 36 14.19 393 201 4.51 / 714.85 3 3
8 8 -0.20 190 14.05 364 972 5.48 / 715.82 3 22
Average= 5.15 (KJ/cycle)

Cycle 137 GMT 16/ 1/2019 5: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 31 14.08 533 233 0.23 / 704.94 3 3
2 12 1121.60 3 9.18 1955 54 0.29 / 704.99 3 3
3 12 2001.92 45 10.16 3219 1472 1.76 / 706.46 3 3
4 7 1999.36 21 10.96 3264 751 2.51 / 707.22 3 3
5 13 1577.72 36 12.56 2659 1202 3.71 / 708.42 3 3
6 13 829.52 36 13.34 1525 732 4.44 / 709.15 3 3
7 13 54.40 36 14.14 450 229 4.67 / 709.38 3 3
8 8 0.16 190 14.10 359 962 5.63 / 710.34 3 15
Average= 5.15 (KJ/cycle)

Cycle 136 GMT 6/ 1/2019 5:34: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 31 14.11 521 228 0.23 / 699.68 3 3
2 12 1091.08 3 9.51 1916 55 0.28 / 699.74 3 3
3 12 2002.08 45 10.23 3207 1476 1.76 / 701.21 3 3
4 7 2000.16 21 10.97 3255 750 2.51 / 701.96 3 3
5 13 1555.08 36 12.61 2601 1181 3.69 / 703.15 3 3
6 13 612.32 36 13.53 1230 599 4.29 / 703.74 3 3
7 8 0.20 190 14.10 359 962 5.25 / 704.71 3 12
Average= 5.14 (KJ/cycle)

Cycle 135 GMT 27/12/2018 5:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 32 14.08 529 238 0.24 / 694.17 3 3
2 3 937.28 -1 14.08 529 0 0.00 / 694.17 3 3
3 12 1135.52 3 9.55 1984 57 0.30 / 694.23 3 3
4 12 2004.56 45 10.25 3231 1490 1.79 / 695.72 3 3
5 7 2002.60 21 10.97 3279 755 2.54 / 696.47 3 3
6 13 1581.08 36 12.57 2674 1210 3.75 / 697.68 3 3
7 13 632.40 36 13.52 1264 615 4.37 / 698.30 3 3
8 13 13.52 36 14.20 390 199 4.57 / 698.50 3 3
9 8 0.00 190 14.06 359 959 5.52 / 699.46 3 15
Average= 5.14 (KJ/cycle)

Cycle 134 GMT 17/12/2018 6:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 32 14.10 517 233 0.23 / 688.66 3 3
2 12 1084.32 3 9.75 1922 56 0.29 / 688.71 3 3
3 12 2004.12 45 10.28 3233 1496 1.79 / 690.21 3 3
4 7 2001.96 21 11.01 3264 755 2.54 / 690.96 3 3
5 13 1568.88 36 12.61 2630 1194 3.73 / 692.16 3 3
6 13 620.28 36 13.55 1231 600 4.33 / 692.76 3 3
7 13 30.88 36 14.19 407 208 4.54 / 692.97 3 3
8 8 0.00 190 14.10 360 964 5.51 / 693.93 3 10
Average= 5.14 (KJ/cycle)

Cycle 133 GMT 7/12/2018 6:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 32 14.11 523 236 0.24 / 683.34 3 3
2 12 1109.36 3 9.89 1957 58 0.29 / 683.40 3 3
3 12 2006.84 45 10.37 3228 1506 1.80 / 684.91 3 3
4 7 2004.80 21 11.00 3273 756 2.56 / 685.66 3 3
5 13 1568.88 36 12.65 2612 1190 3.75 / 686.85 3 3
6 13 631.80 36 13.54 1262 615 4.36 / 687.47 3 3
7 8 0.08 190 14.11 357 957 5.32 / 688.43 3 12
Average= 5.14 (KJ/cycle)

Cycle 132 GMT 27/11/2018 6:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 32 14.06 516 232 0.23 / 677.75 3 3
2 3 969.84 -1 14.06 516 0 0.00 / 677.75 3 3
3 3 1038.24 1 12.35 1918 24 0.26 / 677.77 3 3
4 12 1145.16 3 10.23 2012 62 0.32 / 677.83 3 3
5 12 2005.68 45 10.40 3223 1508 1.83 / 679.34 3 3
6 7 2004.04 21 11.06 3255 756 2.58 / 680.10 3 3
7 13 1788.04 36 12.39 2980 1329 3.91 / 681.43 3 3
8 13 782.76 36 13.40 1469 709 4.62 / 682.14 3 3
9 8 0.32 190 14.10 362 970 5.59 / 683.11 3 10
Average= 5.14 (KJ/cycle)

Cycle 131 GMT 17/11/2018 7:14: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 32 14.08 522 235 0.24 / 672.41 3 3
2 12 1109.68 3 10.27 1963 60 0.30 / 672.47 3 3
3 12 2006.16 45 10.37 3249 1516 1.81 / 673.98 3 3
4 7 2004.04 21 11.02 3289 761 2.57 / 674.74 3 3
5 13 1577.40 36 12.64 2626 1195 3.77 / 675.94 3 3
6 13 626.04 36 13.55 1259 614 4.38 / 676.55 3 3
7 8 0.24 190 14.10 360 964 5.35 / 677.52 3 17
Average= 5.13 (KJ/cycle)

Cycle 130 GMT 7/11/2018 7:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 31 14.07 537 234 0.23 / 667.02 3 3
2 3 1029.88 1 12.41 1904 24 0.26 / 667.04 3 3
3 12 1130.32 3 10.93 2019 66 0.32 / 667.11 3 3
4 12 2003.24 45 10.42 3222 1511 1.83 / 668.62 3 3
5 7 2001.48 21 11.05 3270 759 2.59 / 669.38 3 3
6 13 1578.48 36 12.62 2669 1213 3.81 / 670.59 3 3
7 13 615.68 36 13.55 1234 602 4.41 / 671.19 3 3
8 8 0.16 190 14.09 366 980 5.39 / 672.17 3 12
Average= 5.13 (KJ/cycle)

Cycle 129 GMT 28/10/2018 7:54: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 32 14.10 531 240 0.24 / 661.52 3 3
2 3 961.16 -1 14.10 531 0 0.00 / 661.52 3 3
3 3 1029.28 1 12.05 1904 23 0.26 / 661.54 3 3
4 7 2003.48 62 10.32 3235 2070 2.33 / 663.61 3 3
5 13 1799.08 36 12.34 2995 1330 3.66 / 664.94 3 3
6 13 1046.72 36 13.14 1848 874 4.54 / 665.82 3 3
7 8 -0.12 190 14.09 360 964 5.50 / 666.78 3 8
Average= 5.13 (KJ/cycle)

Cycle 128 GMT 18/10/2018 8:41: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 32 14.09 529 239 0.24 / 655.96 3 3
2 7 2009.28 63 10.33 3238 2107 2.35 / 658.06 3 3
3 13 1792.04 36 12.34 2994 1330 3.68 / 659.39 3 3
4 13 824.00 36 13.34 1532 736 4.41 / 660.13 3 3
5 13 14.20 36 14.21 391 200 4.61 / 660.33 3 3
6 8 0.60 190 14.05 357 953 5.56 / 661.28 3 19
Average= 5.13 (KJ/cycle)

Cycle 127 GMT 8/10/2018 9:22:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 32 14.10 532 240 0.24 / 650.39 3 3
2 7 2006.48 62 10.35 3243 2081 2.32 / 652.47 3 3
3 13 1802.68 36 12.32 3020 1339 3.66 / 653.81 3 3
4 13 848.72 36 13.33 1563 750 4.41 / 654.56 3 3
5 13 31.52 36 14.20 407 208 4.62 / 654.77 3 3
6 8 0.00 190 14.09 354 948 5.57 / 655.72 3 16
Average= 5.12 (KJ/cycle)

Cycle 126 GMT 28/ 9/2018 9:53: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 32 14.10 532 240 0.24 / 644.76 3 3
2 3 965.60 -1 14.10 532 0 0.00 / 644.76 3 3
3 3 1030.88 1 12.31 1892 23 0.26 / 644.79 3 3
4 7 2003.56 63 10.39 3238 2119 2.38 / 646.91 3 3
5 13 1802.64 36 12.33 3018 1340 3.72 / 648.25 3 3
6 13 828.04 36 13.35 1530 735 4.46 / 648.98 3 3
7 13 10.64 36 14.21 391 200 4.66 / 649.18 3 3
8 8 -0.12 190 14.04 363 968 5.63 / 650.15 3 13
Average= 5.12 (KJ/cycle)

Cycle 125 GMT 18/ 9/2018 10:33: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 32 14.09 522 235 0.24 / 639.22 3 3
2 7 2003.12 62 10.39 3228 2079 2.31 / 641.30 3 3
3 13 1792.88 36 12.35 2989 1329 3.64 / 642.63 3 3
4 13 827.84 36 13.35 1530 735 4.38 / 643.36 3 3
5 13 12.12 36 14.20 391 200 4.58 / 643.56 3 3
6 8 0.00 190 14.04 361 963 5.54 / 644.52 3 16
Average= 5.12 (KJ/cycle)

Cycle 124 GMT 8/ 9/2018 11: 2: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 32 14.13 517 234 0.23 / 633.85 3 3
2 7 2006.56 62 10.50 3242 2111 2.34 / 635.96 3 3
3 13 1790.92 36 12.38 2967 1322 3.67 / 637.29 3 3
4 13 819.04 36 13.35 1513 727 4.39 / 638.01 3 3
5 8 -0.08 190 14.08 362 968 5.36 / 638.98 3 12
Average= 5.11 (KJ/cycle)

Cycle 123 GMT 29/ 8/2018 11:33:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 32 14.10 525 237 0.24 / 628.46 3 3
2 3 970.56 -1 14.10 525 0 0.00 / 628.46 3 3
3 3 1045.24 1 12.63 1924 24 0.26 / 628.49 3 3
4 7 2000.84 62 10.49 3239 2107 2.37 / 630.60 3 3
5 13 1784.20 36 12.37 2969 1322 3.69 / 631.92 3 3
6 13 818.20 36 13.36 1521 732 4.42 / 632.65 3 3
7 8 0.28 190 14.08 363 971 5.39 / 633.62 3 5
Average= 5.11 (KJ/cycle)

Cycle 122 GMT 19/ 8/2018 12:18: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 32 14.10 527 238 0.24 / 622.84 3 3
2 7 2009.52 63 10.40 3258 2135 2.37 / 624.97 3 3
3 13 1795.16 36 12.34 2963 1316 3.69 / 626.29 3 3
4 13 839.28 36 13.35 1535 738 4.43 / 627.03 3 3
5 13 68.92 36 14.14 465 237 4.66 / 627.26 3 3
6 8 0.32 190 14.09 360 964 5.63 / 628.23 3 12
Average= 5.11 (KJ/cycle)

Cycle 121 GMT 9/ 8/2018 12:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 32 14.10 535 241 0.24 / 617.35 3 3
2 7 2006.56 62 10.51 3234 2107 2.35 / 619.45 3 3
3 13 1597.60 36 12.56 2701 1221 3.57 / 620.67 3 3
4 13 895.08 36 13.30 1624 778 4.35 / 621.45 3 3
5 13 3.12 36 14.23 373 191 4.54 / 621.64 3 3
6 8 -0.12 190 14.05 359 958 5.50 / 622.60 3 16
Average= 5.10 (KJ/cycle)

Cycle 120 GMT 30/ 7/2018 13:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 32 14.10 536 242 0.24 / 611.80 3 3
2 7 2005.64 63 10.49 3248 2147 2.39 / 613.95 3 3
3 13 1588.24 36 12.59 2659 1205 3.59 / 615.15 3 3
4 13 882.12 36 13.31 1604 769 4.36 / 615.92 3 3
5 13 38.16 36 14.18 426 217 4.58 / 616.14 3 3
6 8 0.16 190 14.08 361 966 5.55 / 617.10 3 9
Average= 5.10 (KJ/cycle)

Cycle 119 GMT 20/ 7/2018 13:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 31 14.11 530 232 0.23 / 606.09 3 3
2 7 2003.64 62 10.54 3255 2127 2.36 / 608.22 3 3
3 13 1800.40 36 12.38 2990 1333 3.69 / 609.55 3 3
4 13 836.60 36 13.36 1535 738 4.43 / 610.29 3 3
5 13 138.48 36 14.07 567 287 4.72 / 610.58 3 3
6 8 0.32 190 14.10 367 983 5.70 / 611.56 3 13
Average= 5.10 (KJ/cycle)

Cycle 118 GMT 10/ 7/2018 14:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 31 14.14 522 229 0.23 / 600.80 3 3
2 7 2001.48 62 10.59 3238 2126 2.35 / 602.92 3 3
3 13 1596.28 36 12.59 2669 1210 3.56 / 604.13 3 3
4 13 870.60 36 13.32 1583 759 4.32 / 604.89 3 3
5 8 0.08 190 14.09 361 966 5.29 / 605.86 3 14
Average= 5.09 (KJ/cycle)

Cycle 117 GMT 30/ 6/2018 14:58: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 32 14.14 533 241 0.24 / 595.19 3 3
2 3 969.56 -1 14.14 533 0 0.00 / 595.19 3 3
3 3 1034.00 1 12.33 1915 24 0.26 / 595.21 3 3
4 7 2006.64 62 10.60 3244 2132 2.40 / 597.34 3 3
5 13 1795.80 36 12.39 2970 1325 3.72 / 598.67 3 3
6 13 820.04 36 13.37 1523 733 4.45 / 599.40 3 3
7 13 28.40 36 14.20 407 208 4.66 / 599.61 3 3
8 8 0.12 190 14.09 359 961 5.62 / 600.57 3 13
Average= 5.09 (KJ/cycle)

Cycle 116 GMT 20/ 6/2018 15:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 32 14.13 515 233 0.23 / 589.57 3 3
2 7 2007.76 62 10.57 3260 2136 2.37 / 591.71 3 3
3 13 1787.04 36 12.39 2982 1330 3.70 / 593.04 3 3
4 13 817.36 36 13.37 1522 733 4.43 / 593.77 3 3
5 13 25.12 36 14.22 394 202 4.63 / 593.97 3 3
6 8 -0.08 190 14.08 363 971 5.60 / 594.95 3 17
Average= 5.09 (KJ/cycle)

Cycle 115 GMT 10/ 6/2018 16:23: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 32 14.16 517 234 0.23 / 584.16 3 3
2 7 2001.16 63 10.62 3248 2173 2.41 / 586.33 3 3
3 13 1784.28 36 12.40 2953 1318 3.73 / 587.65 3 3
4 13 822.72 36 13.37 1526 734 4.46 / 588.38 3 3
5 8 0.00 190 14.10 358 959 5.42 / 589.34 3 9
Average= 5.08 (KJ/cycle)

Cycle 114 GMT 31/ 5/2018 17: 6: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 32 14.13 529 239 0.24 / 578.86 3 3
2 7 2003.12 62 10.63 3255 2145 2.38 / 581.00 3 3
3 13 1585.88 36 12.58 2682 1215 3.60 / 582.22 3 3
4 13 845.72 36 13.37 1549 746 4.34 / 582.96 3 3
5 8 0.24 190 14.10 358 959 5.30 / 583.92 3 14
Average= 5.08 (KJ/cycle)

Cycle 113 GMT 21/ 5/2018 17:47: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 32 14.14 533 241 0.24 / 573.64 3 3
2 7 2008.44 62 10.60 3267 2147 2.39 / 575.79 3 3
3 13 1591.04 36 12.61 2675 1214 3.60 / 577.00 3 3
4 13 664.52 36 13.52 1308 637 4.24 / 577.64 3 3
5 8 0.04 190 14.09 366 980 5.22 / 578.62 3 13
Average= 5.08 (KJ/cycle)

Cycle 112 GMT 11/ 5/2018 18:18: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 31 14.15 523 229 0.23 / 568.11 3 3
2 7 2003.48 62 10.69 3255 2157 2.39 / 570.27 3 3
3 13 1582.12 36 12.63 2647 1204 3.59 / 571.47 3 3
4 13 850.00 36 13.36 1559 750 4.34 / 572.22 3 3
5 13 28.88 36 14.20 411 210 4.55 / 572.43 3 3
6 8 0.36 190 14.08 362 968 5.52 / 573.40 3 15
Average= 5.07 (KJ/cycle)

Cycle 111 GMT 1/ 5/2018 18:50: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 31 14.18 523 230 0.23 / 562.79 3 3
2 7 2008.88 62 10.66 3265 2158 2.39 / 564.95 3 3
3 13 1593.56 36 12.63 2637 1199 3.59 / 566.15 3 3
4 13 857.88 36 13.36 1576 758 4.34 / 566.90 3 3
5 8 0.52 190 14.10 364 975 5.32 / 567.88 3 13
Average= 5.07 (KJ/cycle)

Cycle 110 GMT 21/ 4/2018 19:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 31 14.14 526 231 0.23 / 557.17 3 3
2 7 2009.60 62 10.67 3269 2163 2.39 / 559.33 3 3
3 13 1793.36 36 12.42 2989 1336 3.73 / 560.67 3 3
4 13 800.12 36 13.42 1494 722 4.45 / 561.39 3 3
5 13 13.88 36 14.23 395 202 4.65 / 561.59 3 3
6 8 -0.24 190 14.05 363 969 5.62 / 562.56 3 15
Average= 5.07 (KJ/cycle)

Cycle 109 GMT 11/ 4/2018 20: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 31 14.18 531 233 0.23 / 551.51 3 3
2 3 969.84 -1 14.18 531 0 0.00 / 551.51 3 3
3 3 1044.64 1 12.63 1927 24 0.26 / 551.54 3 3
4 7 2002.20 62 10.77 3246 2167 2.43 / 553.71 3 3
5 13 1795.48 36 12.42 3007 1344 3.77 / 555.05 3 3
6 13 805.00 36 13.41 1496 722 4.49 / 555.77 3 3
7 13 14.84 36 14.22 393 201 4.69 / 555.97 3 3
8 8 0.16 190 14.04 361 963 5.66 / 556.94 3 12
Average= 5.06 (KJ/cycle)

Cycle 108 GMT 1/ 4/2018 20:52: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 31 14.17 523 230 0.23 / 545.80 3 3
2 7 2003.84 62 10.74 3268 2176 2.41 / 547.97 3 3
3 13 1785.80 36 12.44 2950 1321 3.73 / 549.30 3 3
4 13 801.32 36 13.43 1469 710 4.44 / 550.01 3 3
5 13 136.24 36 14.08 569 288 4.73 / 550.29 3 3
6 8 0.28 190 14.11 368 987 5.71 / 551.28 3 16
Average= 5.06 (KJ/cycle)

Cycle 107 GMT 22/ 3/2018 21:23: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 31 14.16 534 234 0.23 / 540.52 3 3
2 7 2007.00 63 10.78 3269 2220 2.45 / 542.74 3 3
3 13 1595.00 36 12.64 2670 1215 3.67 / 543.96 3 3
4 13 674.48 36 13.53 1312 639 4.31 / 544.60 3 3
5 8 0.24 190 14.10 363 972 5.28 / 545.57 3 12
Average= 5.05 (KJ/cycle)

Cycle 106 GMT 12/ 3/2018 21:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 32 14.17 520 236 0.24 / 535.03 3 3
2 3 965.24 -1 14.17 520 0 0.00 / 535.03 3 3
3 3 1039.04 1 12.49 1921 24 0.26 / 535.05 3 3
4 7 2009.40 62 10.81 3269 2191 2.45 / 537.24 3 3
5 13 1792.28 36 12.46 2968 1331 3.78 / 538.57 3 3
6 13 809.32 36 13.41 1503 726 4.51 / 539.30 3 3
7 8 0.04 190 14.08 370 990 5.50 / 540.29 3 9
Average= 5.05 (KJ/cycle)

Cycle 105 GMT 2/ 3/2018 22:27: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 32 14.19 522 237 0.24 / 529.66 3 3
2 7 2005.64 63 10.81 3252 2215 2.45 / 531.87 3 3
3 13 1582.36 36 12.67 2626 1198 3.65 / 533.07 3 3
4 13 859.12 36 13.38 1573 758 4.41 / 533.83 3 3
5 8 0.28 190 14.11 359 962 5.37 / 534.79 3 15
Average= 5.05 (KJ/cycle)

Cycle 104 GMT 20/ 2/2018 23: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 32 14.14 526 238 0.24 / 524.17 3 3
2 3 958.24 -1 14.14 526 0 0.00 / 524.17 3 3
3 3 1024.24 1 11.57 1883 22 0.26 / 524.19 3 3
4 7 2004.32 62 10.84 3255 2188 2.45 / 526.38 3 3
5 13 1793.08 36 12.46 2990 1341 3.79 / 527.72 3 3
6 13 794.52 36 13.43 1489 720 4.51 / 528.44 3 3
7 8 -0.08 190 14.09 366 980 5.49 / 529.42 3 16
Average= 5.04 (KJ/cycle)

Cycle 103 GMT 10/ 2/2018 23:58: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 32 14.16 547 248 0.25 / 518.77 3 3
2 3 972.60 -1 14.16 547 0 0.00 / 518.77 3 3
3 3 1043.88 1 12.51 1923 24 0.27 / 518.80 3 3
4 7 2008.88 62 10.86 3259 2194 2.47 / 520.99 3 3
5 13 1589.44 36 12.65 2671 1216 3.68 / 522.21 3 3
6 13 856.92 36 13.38 1585 763 4.45 / 522.97 3 3
7 8 0.40 190 14.11 359 962 5.41 / 523.93 3 13
Average= 5.04 (KJ/cycle)

Cycle 102 GMT 1/ 2/2018 0:40: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 31 14.15 534 234 0.23 / 513.37 3 3
2 3 1030.32 1 12.21 1905 23 0.26 / 513.40 3 3
3 3 1023.32 1 11.96 1893 23 0.28 / 513.42 3 3
4 7 2008.48 62 10.90 3253 2198 2.48 / 515.62 3 3
5 13 1579.76 36 12.68 2650 1210 3.69 / 516.83 3 3
6 13 832.84 36 13.41 1534 741 4.43 / 517.57 3 3
7 8 0.08 190 14.11 357 957 5.39 / 518.52 3 12
Average= 5.03 (KJ/cycle)

Cycle 101 GMT 22/ 1/2018 1:16: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 31 14.20 523 230 0.23 / 508.11 3 3
2 7 2000.92 63 10.90 3257 2237 2.47 / 510.35 3 3
3 13 1582.36 36 12.69 2643 1207 3.67 / 511.56 3 3
4 13 646.48 36 13.59 1263 618 4.29 / 512.18 3 3
5 8 0.24 190 14.11 359 962 5.25 / 513.14 3 11
Average= 5.03 (KJ/cycle)

Cycle 100 GMT 12/ 1/2018 1:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 31 14.19 517 227 0.23 / 502.64 3 3
2 7 2002.52 63 10.93 3260 2245 2.47 / 504.89 3 3
3 13 1781.68 36 12.51 2952 1329 3.80 / 506.22 3 3
4 13 784.08 36 13.44 1467 710 4.51 / 506.93 3 3
5 8 0.00 190 14.11 357 957 5.47 / 507.88 3 16
Average= 5.03 (KJ/cycle)

Cycle 99 GMT 2/ 1/2018 2:39: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 31 14.19 536 236 0.24 / 497.11 3 3
2 3 970.24 -1 14.19 536 0 0.00 / 497.11 3 3
3 3 1040.48 1 12.52 1916 24 0.26 / 497.13 3 3
4 7 2005.08 63 10.99 3257 2255 2.51 / 499.39 3 3
5 13 1791.36 36 12.49 2982 1341 3.86 / 500.73 3 3
6 13 786.92 36 13.44 1462 707 4.56 / 501.44 3 3
7 8 0.12 190 14.09 365 977 5.54 / 502.41 3 12
Average= 5.02 (KJ/cycle)

Cycle 98 GMT 23/12/2017 3:29: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 32 14.15 530 240 0.24 / 491.35 3 3
2 3 965.92 -1 14.15 530 0 0.00 / 491.35 3 3
3 3 1035.84 1 12.46 1910 24 0.26 / 491.37 3 3
4 7 2002.04 63 11.00 3261 2260 2.52 / 493.63 3 3
5 13 1780.80 36 12.49 2980 1340 3.86 / 494.97 3 3
6 13 779.32 36 13.47 1455 706 4.57 / 495.67 3 3
7 13 47.08 36 14.20 443 226 4.80 / 495.90 3 3
8 8 0.20 190 14.08 364 974 5.77 / 496.87 3 12
Average= 5.02 (KJ/cycle)

Cycle 97 GMT 13/12/2017 4:23:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 32 14.16 528 239 0.24 / 485.82 3 3
2 3 957.96 -1 14.16 528 0 0.00 / 485.82 3 3
3 3 1032.92 1 12.19 1906 23 0.26 / 485.85 3 3
4 7 2002.16 63 11.02 3263 2265 2.53 / 488.11 3 3
5 13 1578.48 36 12.73 2631 1206 3.73 / 489.32 3 3
6 13 629.88 36 13.59 1267 620 4.35 / 489.94 3 3
7 13 1.56 36 14.27 382 196 4.55 / 490.13 3 3
8 8 -0.16 190 14.04 364 971 5.52 / 491.11 3 16
Average= 5.01 (KJ/cycle)

Cycle 96 GMT 3/12/2017 5: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 32 14.16 531 241 0.24 / 480.35 3 3
2 7 2007.96 62 10.95 3263 2215 2.46 / 482.56 3 3
3 13 1788.60 36 12.52 2958 1333 3.79 / 483.90 3 3
4 13 790.64 36 13.44 1475 714 4.50 / 484.61 3 3
5 8 0.08 190 14.08 364 974 5.48 / 485.58 3 15
Average= 5.01 (KJ/cycle)

Cycle 95 GMT 23/11/2017 5:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 32 14.16 529 240 0.24 / 475.06 3 3
2 7 2006.60 62 10.97 3266 2221 2.46 / 477.28 3 3
3 13 1587.08 36 12.72 2638 1208 3.67 / 478.49 3 3
4 13 650.08 36 13.56 1301 635 4.30 / 479.12 3 3
5 8 0.20 190 14.08 368 984 5.29 / 480.11 3 15
Average= 5.00 (KJ/cycle)

Cycle 94 GMT 13/11/2017 6:15: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 32 14.16 535 242 0.24 / 469.68 3 3
2 7 2002.56 62 11.00 3258 2222 2.46 / 471.90 3 3
3 13 1572.16 36 12.72 2637 1208 3.67 / 473.11 3 3
4 13 825.92 36 13.43 1518 734 4.41 / 473.85 3 3
5 8 0.16 190 14.09 364 974 5.38 / 474.82 3 14
Average= 5.00 (KJ/cycle)

Cycle 93 GMT 3/11/2017 7: 0: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 32 14.15 548 248 0.25 / 464.38 3 3
2 7 2007.32 63 10.99 3269 2263 2.51 / 466.64 3 3
3 13 1579.12 36 12.73 2631 1206 3.72 / 467.85 3 3
4 13 631.04 36 13.59 1272 622 4.34 / 468.47 3 3
5 8 0.36 190 14.09 363 972 5.31 / 469.44 3 12
Average= 4.99 (KJ/cycle)

Cycle 92 GMT 24/10/2017 7:37: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 32 14.15 538 244 0.24 / 458.93 3 3
2 7 2002.24 63 11.02 3261 2264 2.51 / 461.19 3 3
3 13 1570.48 36 12.75 2619 1202 3.71 / 462.39 3 3
4 13 835.96 36 13.43 1534 742 4.45 / 463.14 3 3
5 8 0.08 190 14.07 371 992 5.44 / 464.13 3 15
Average= 4.99 (KJ/cycle)

Cycle 91 GMT 14/10/2017 8:13: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 32 14.14 535 242 0.24 / 453.65 3 3
2 7 2005.24 62 11.02 3267 2232 2.47 / 455.88 3 3
3 13 1579.24 36 12.74 2626 1204 3.68 / 457.08 3 3
4 13 647.92 36 13.58 1289 630 4.31 / 457.71 3 3
5 8 0.60 190 14.09 363 972 5.28 / 458.68 3 21
Average= 4.99 (KJ/cycle)

Cycle 90 GMT 4/10/2017 8:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 33 14.21 532 249 0.25 / 448.31 3 3
2 3 972.96 -1 14.21 532 0 0.00 / 448.31 3 3
3 3 1041.16 1 12.75 1907 24 0.27 / 448.33 3 3
4 7 2007.64 62 11.09 3265 2245 2.52 / 450.58 3 3
5 13 1570.80 36 12.77 2617 1203 3.72 / 451.78 3 3
6 13 630.40 36 13.60 1277 625 4.35 / 452.41 3 3
7 8 -0.16 190 14.07 373 997 5.34 / 453.40 3 10
Average= 4.98 (KJ/cycle)

Cycle 89 GMT 24/ 9/2017 9:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 33 14.19 550 258 0.26 / 442.95 3 3
2 7 2004.20 63 11.07 3269 2280 2.54 / 445.23 3 3
3 13 1583.60 36 12.75 2657 1220 3.76 / 446.45 3 3
4 13 632.04 36 13.61 1271 623 4.38 / 447.07 3 3
5 8 -0.04 190 14.07 371 992 5.37 / 448.06 3 14
Average= 4.98 (KJ/cycle)

Cycle 88 GMT 14/ 9/2017 9:45: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 33 14.18 525 246 0.25 / 437.65 3 3
2 7 2004.36 62 11.10 3260 2244 2.49 / 439.89 3 3
3 13 1559.08 36 12.77 2630 1209 3.70 / 441.10 3 3
4 13 608.40 36 13.62 1241 608 4.31 / 441.71 3 3
5 8 0.24 190 14.08 366 979 5.29 / 442.69 3 14
Average= 4.97 (KJ/cycle)

Cycle 87 GMT 4/ 9/2017 10:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 33 14.18 542 254 0.25 / 432.13 3 3
2 3 971.68 -1 14.18 542 0 0.00 / 432.13 3 3
3 3 1041.68 1 12.86 1937 25 0.28 / 432.15 3 3
4 7 2004.36 62 11.11 3247 2237 2.52 / 434.39 3 3
5 13 1785.64 36 12.60 2918 1324 3.84 / 435.71 3 3
6 13 770.08 36 13.47 1464 710 4.55 / 436.42 3 3
7 8 0.12 190 14.08 367 982 5.53 / 437.40 3 11
Average= 4.97 (KJ/cycle)

Cycle 86 GMT 25/ 8/2017 11:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 32 14.22 541 246 0.25 / 426.76 3 3
2 3 1019.60 1 11.43 1895 22 0.27 / 426.78 3 3
3 7 2006.20 63 11.12 3265 2287 2.56 / 429.07 3 3
4 13 1579.68 36 12.77 2651 1219 3.77 / 430.28 3 3
5 13 616.20 36 13.62 1250 613 4.39 / 430.90 3 3
6 8 -0.04 190 14.09 364 974 5.36 / 431.87 3 13
Average= 4.96 (KJ/cycle)

Cycle 85 GMT 15/ 8/2017 11:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 32 14.19 539 245 0.24 / 421.46 3 3
2 7 2009.48 62 11.06 3259 2235 2.48 / 423.70 3 3
3 13 1563.44 36 12.80 2601 1199 3.68 / 424.89 3 3
4 13 620.80 36 13.63 1258 617 4.30 / 425.51 3 3
5 8 0.12 190 14.07 374 1000 5.30 / 426.51 3 18
Average= 4.96 (KJ/cycle)

Cycle 84 GMT 5/ 8/2017 12:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 32 14.24 528 241 0.24 / 415.73 3 3
2 7 2003.28 63 11.02 3256 2261 2.50 / 417.99 3 3
3 13 1786.88 36 12.59 2967 1345 3.85 / 419.33 3 3
4 13 776.88 36 13.51 1438 699 4.55 / 420.03 3 3
5 13 10.32 36 14.27 398 204 4.75 / 420.24 3 3
6 8 0.44 190 14.01 368 980 5.73 / 421.22 3 16
Average= 4.96 (KJ/cycle)

Cycle 83 GMT 26/ 7/2017 13: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 32 14.24 527 240 0.24 / 410.14 3 3
2 7 2009.48 63 11.09 3265 2281 2.52 / 412.43 3 3
3 13 1583.32 36 12.77 2698 1240 3.76 / 413.67 3 3
4 13 614.24 36 13.63 1262 619 4.38 / 414.29 3 3
5 13 27.24 36 14.26 419 215 4.60 / 414.50 3 4
6 8 -0.36 190 14.06 369 986 5.58 / 415.49 3 20
Average= 4.95 (KJ/cycle)

Cycle 82 GMT 16/ 7/2017 13:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 32 14.22 544 248 0.25 / 404.83 3 3
2 7 2004.32 62 10.99 3261 2222 2.47 / 407.05 3 3
3 13 1583.40 36 12.78 2670 1228 3.70 / 408.28 3 3
4 13 631.28 36 13.64 1274 626 4.32 / 408.90 3 3
5 8 0.44 190 14.08 375 1003 5.33 / 409.90 3 14
Average= 4.94 (KJ/cycle)

Cycle 81 GMT 6/ 7/2017 14: 4: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 32 14.22 533 243 0.24 / 399.06 3 3
2 3 972.72 -1 14.22 533 0 0.00 / 399.06 3 3
3 3 1035.96 1 12.97 1924 25 0.27 / 399.08 3 3
4 7 2005.08 62 10.98 3249 2212 2.48 / 401.30 3 3
5 13 1785.20 36 12.62 2948 1339 3.82 / 402.63 3 3
6 13 785.92 36 13.49 1470 714 4.53 / 403.35 3 3
7 13 52.32 36 14.23 458 235 4.77 / 403.58 3 3
8 8 -0.20 190 14.08 372 995 5.76 / 404.58 3 17
Average= 4.93 (KJ/cycle)

Cycle 80 GMT 26/ 6/2017 14:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 31 14.21 537 237 0.24 / 393.75 3 3
2 3 1031.52 1 12.98 1927 25 0.26 / 393.77 3 3
3 7 2008.56 62 10.96 3243 2204 2.47 / 395.98 3 3
4 13 1584.04 36 12.81 2634 1215 3.68 / 397.19 3 3
5 13 651.24 36 13.62 1299 637 4.32 / 397.83 3 3
6 8 0.12 190 14.10 369 989 5.31 / 398.82 3 11
Average= 4.92 (KJ/cycle)

Cycle 79 GMT 16/ 6/2017 15:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 32 14.24 543 247 0.25 / 388.36 3 3
2 3 972.96 -1 14.24 543 0 0.00 / 388.36 3 3
3 7 2005.44 62 10.87 3260 2197 2.44 / 390.56 3 3
4 13 1584.92 36 12.82 2625 1211 3.66 / 391.77 3 3
5 13 847.08 36 13.47 1561 757 4.41 / 392.52 3 3
6 8 0.40 190 14.10 368 986 5.40 / 393.51 3 12
Average= 4.92 (KJ/cycle)

Cycle 78 GMT 6/ 6/2017 16:14: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 32 14.25 537 245 0.24 / 382.67 3 3
2 7 2000.92 63 10.86 3236 2214 2.46 / 384.89 3 3
3 13 1780.80 36 12.62 2963 1346 3.81 / 386.23 3 3
4 13 789.00 36 13.52 1472 716 4.52 / 386.95 3 3
5 13 8.84 36 14.31 385 198 4.72 / 387.15 3 3
6 8 -0.12 190 14.03 362 965 5.68 / 388.11 3 17
Average= 4.91 (KJ/cycle)

Cycle 77 GMT 27/ 5/2017 16:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 33 14.26 536 252 0.25 / 377.35 3 3
2 3 970.44 -1 14.26 536 0 0.00 / 377.35 3 3
3 3 1040.48 1 13.24 1931 26 0.28 / 377.37 3 3
4 7 2005.28 63 10.92 3226 2219 2.50 / 379.59 3 3
5 13 1583.72 36 12.84 2636 1218 3.72 / 380.81 3 3
6 13 640.28 36 13.66 1287 633 4.35 / 381.44 3 3
7 8 0.16 190 14.11 367 984 5.33 / 382.43 3 15
Average= 4.90 (KJ/cycle)

Cycle 76 GMT 17/ 5/2017 17:33:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 32 14.29 521 238 0.24 / 372.02 3 3
2 3 1027.32 1 12.82 1911 24 0.26 / 372.05 3 3
3 7 2009.32 63 10.88 3250 2228 2.49 / 374.28 3 3
4 13 1580.80 36 12.85 2639 1221 3.71 / 375.50 3 3
5 13 637.92 36 13.67 1271 625 4.34 / 376.12 3 3
6 8 0.08 190 14.13 362 972 5.31 / 377.09 3 15
Average= 4.90 (KJ/cycle)

Cycle 75 GMT 7/ 5/2017 18: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 33 14.29 509 240 0.24 / 366.56 3 3
2 3 953.96 -1 14.29 509 0 0.00 / 366.56 3 3
3 7 2008.04 62 10.85 3232 2174 2.41 / 368.73 3 3
4 13 1794.60 36 12.64 2967 1350 3.76 / 370.08 3 3
5 13 802.40 36 13.54 1489 726 4.49 / 370.81 3 3
6 8 0.36 190 14.12 364 977 5.47 / 371.79 3 12
Average= 4.89 (KJ/cycle)

Cycle 74 GMT 27/ 4/2017 18:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 33 14.28 527 248 0.25 / 361.18 3 3
2 7 2006.16 52 10.88 3236 1831 2.08 / 363.01 3 3
3 13 1823.28 36 12.63 2985 1357 3.44 / 364.37 3 3
4 13 891.84 36 13.47 1617 784 4.22 / 365.15 3 3
5 13 15.96 36 14.31 398 205 4.43 / 365.36 3 3
6 8 0.00 190 14.04 360 960 5.39 / 366.32 3 16
Average= 4.88 (KJ/cycle)

Cycle 73 GMT 17/ 4/2017 19: 3: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 33 14.32 523 247 0.25 / 355.96 3 3
2 7 2007.28 53 10.88 3228 1861 2.11 / 357.82 3 3
3 13 1622.16 36 12.83 2691 1243 3.35 / 359.07 3 3
4 13 733.92 36 13.61 1414 693 4.04 / 359.76 3 3
5 13 16.60 36 14.33 399 206 4.25 / 359.97 3 3
6 8 0.00 190 14.10 361 967 5.22 / 360.93 3 17
Average= 4.88 (KJ/cycle)

Cycle 72 GMT 7/ 4/2017 19:21: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 33 14.33 514 243 0.24 / 350.75 3 3
2 7 2007.52 52 10.99 3239 1851 2.09 / 352.60 3 3
3 13 1807.96 36 12.63 3021 1374 3.47 / 353.97 3 3
4 13 870.48 36 13.49 1592 773 4.24 / 354.74 3 3
5 8 0.04 190 14.13 362 972 5.21 / 355.72 3 12
Average= 4.87 (KJ/cycle)

Cycle 71 GMT 28/ 3/2017 19:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 33 14.30 529 250 0.25 / 345.71 3 3
2 7 2006.52 52 11.01 3228 1848 2.10 / 347.56 3 3
3 13 1624.44 36 12.85 2689 1244 3.34 / 348.80 3 3
4 13 754.40 36 13.60 1441 706 4.05 / 349.51 3 3
5 8 0.28 190 14.13 371 996 5.04 / 350.50 3 15
Average= 4.87 (KJ/cycle)

Cycle 70 GMT 18/ 3/2017 19:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 33 14.32 512 242 0.24 / 340.71 3 3
2 7 2003.40 52 11.06 3242 1865 2.11 / 342.57 3 3
3 13 1621.56 36 12.85 2673 1237 3.34 / 343.81 3 3
4 13 738.24 36 13.63 1407 690 4.03 / 344.50 3 3
5 8 -0.04 190 14.14 357 959 4.99 / 345.46 3 11
Average= 4.87 (KJ/cycle)

Cycle 69 GMT 8/ 3/2017 20: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 32 14.32 521 239 0.24 / 335.67 3 3
2 7 2003.36 52 11.12 3250 1879 2.12 / 337.55 3 3
3 13 1621.64 36 12.86 2701 1250 3.37 / 338.80 3 3
4 13 733.28 36 13.62 1425 699 4.07 / 339.50 3 3
5 8 0.24 190 14.15 361 971 5.04 / 340.47 3 14
Average= 4.86 (KJ/cycle)

Cycle 68 GMT 26/ 2/2017 20:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 32 14.31 532 244 0.24 / 330.68 3 3
2 7 2003.80 53 11.10 3263 1920 2.16 / 332.60 3 3
3 13 1604.72 35 12.89 2650 1196 3.36 / 333.79 3 3
4 13 717.80 35 13.65 1387 663 4.02 / 334.45 3 3
5 8 0.24 190 14.14 363 975 5.00 / 335.43 3 17
Average= 4.86 (KJ/cycle)

Cycle 67 GMT 16/ 2/2017 20:30: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 32 14.34 514 236 0.24 / 325.47 3 3
2 7 2004.00 52 11.18 3258 1894 2.13 / 327.37 3 3
3 13 1623.24 35 12.88 2690 1213 3.34 / 328.58 3 3
4 13 737.84 35 13.64 1427 681 4.02 / 329.26 3 3
5 13 19.68 35 14.33 404 203 4.23 / 329.46 3 3
6 8 0.00 190 14.09 362 969 5.20 / 330.43 3 18
Average= 4.86 (KJ/cycle)

Cycle 66 GMT 6/ 2/2017 20:42: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 32 14.33 532 244 0.24 / 320.43 3 3
2 7 2002.44 50 11.22 3270 1834 2.08 / 322.27 3 3
3 13 1616.36 33 12.93 2714 1158 3.24 / 323.42 3 3
4 13 746.84 33 13.66 1445 651 3.89 / 324.08 3 3
5 13 25.48 33 14.33 419 198 4.09 / 324.27 3 3
6 8 0.16 190 14.10 360 964 5.05 / 325.24 3 14
Average= 4.85 (KJ/cycle)

Cycle 65 GMT 27/ 1/2017 20:52: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 32 14.36 511 235 0.23 / 315.26 3 3
2 7 2008.08 50 11.30 3282 1854 2.09 / 317.11 3 3
3 13 1624.16 33 12.95 2697 1153 3.24 / 318.26 3 3
4 13 936.44 33 13.52 1688 753 3.99 / 319.02 3 3
5 13 38.40 33 14.31 435 205 4.20 / 319.22 3 3
6 8 0.04 190 14.12 360 966 5.17 / 320.19 3 18
Average= 4.85 (KJ/cycle)

Cycle 64 GMT 17/ 1/2017 20:59: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 32 14.37 510 235 0.23 / 310.10 3 3
2 7 2001.12 50 11.34 3290 1865 2.10 / 311.97 3 3
3 13 1617.76 33 12.98 2688 1151 3.25 / 313.12 3 3
4 13 919.64 33 13.55 1661 743 3.99 / 313.86 3 3
5 13 40.56 33 14.33 430 203 4.20 / 314.06 3 3
6 8 0.44 190 14.13 357 958 5.16 / 315.02 3 14
Average= 4.85 (KJ/cycle)

Cycle 63 GMT 7/ 1/2017 21:14: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 32 14.35 522 240 0.24 / 305.01 3 3
2 7 2008.00 51 11.48 3262 1910 2.15 / 306.92 3 3
3 13 1607.80 33 12.98 2656 1138 3.29 / 308.06 3 3
4 13 746.08 33 13.68 1447 653 3.94 / 308.71 3 3
5 13 13.24 33 14.35 400 189 4.13 / 308.90 3 3
6 8 0.40 190 14.08 361 966 5.10 / 309.87 3 20
Average= 4.84 (KJ/cycle)

Cycle 62 GMT 28/12/2016 21:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 32 14.34 529 243 0.24 / 299.87 3 3
2 7 2007.20 51 11.60 3289 1946 2.19 / 301.81 3 3
3 13 1613.88 33 12.98 2694 1154 3.34 / 302.97 3 3
4 13 743.28 33 13.69 1433 647 3.99 / 303.61 3 3
5 13 23.52 33 14.34 418 198 4.19 / 303.81 3 3
6 8 0.28 190 14.11 357 957 5.14 / 304.77 3 18
Average= 4.84 (KJ/cycle)

Cycle 61 GMT 18/12/2016 21:14: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 32 14.35 526 242 0.24 / 294.90 3 3
2 7 2009.00 51 11.68 3283 1956 2.20 / 296.86 3 3
3 13 1617.92 33 13.02 2666 1145 3.34 / 298.00 3 3
4 13 740.00 33 13.70 1432 647 3.99 / 298.65 3 3
5 8 0.04 190 14.15 363 976 4.97 / 299.63 3 10
Average= 4.83 (KJ/cycle)

Cycle 60 GMT 8/12/2016 21:18: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 32 14.35 525 241 0.24 / 289.92 3 3
2 7 2004.04 51 11.74 3270 1958 2.20 / 291.88 3 3
3 13 1613.96 33 13.03 2675 1150 3.35 / 293.03 3 3
4 13 727.28 33 13.71 1423 644 3.99 / 293.67 3 3
5 8 0.32 190 14.15 368 989 4.98 / 294.66 3 11
Average= 4.83 (KJ/cycle)

Cycle 59 GMT 28/11/2016 21:29: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 32 14.33 529 243 0.24 / 284.85 3 3
2 7 2007.88 50 11.78 3292 1939 2.18 / 286.79 3 3
3 13 1617.96 33 13.02 2715 1167 3.35 / 287.95 3 3
4 13 918.60 33 13.57 1667 746 4.09 / 288.70 3 3
5 8 0.08 190 14.15 364 979 5.07 / 289.68 3 11
Average= 4.83 (KJ/cycle)

Cycle 58 GMT 18/11/2016 21:53: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 32 14.35 525 241 0.24 / 279.88 3 3
2 7 2001.56 50 11.84 3279 1941 2.18 / 281.83 3 3
3 13 1599.40 33 13.06 2662 1147 3.33 / 282.97 3 3
4 13 730.40 33 13.73 1415 641 3.97 / 283.61 3 3
5 8 0.04 190 14.15 368 989 4.96 / 284.60 3 14
Average= 4.82 (KJ/cycle)

Cycle 57 GMT 8/11/2016 22: 2:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 32 14.32 522 239 0.24 / 274.70 3 3
2 7 2006.60 51 11.89 3293 1997 2.24 / 276.69 3 3
3 13 1595.40 33 13.07 2685 1158 3.39 / 277.85 3 3
4 13 701.80 33 13.75 1375 624 4.02 / 278.48 3 3
5 13 20.20 33 14.36 410 194 4.21 / 278.67 3 3
6 8 0.36 190 14.11 363 973 5.19 / 279.64 3 17
Average= 4.82 (KJ/cycle)

Cycle 56 GMT 29/10/2016 22:18: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 32 14.34 536 246 0.25 / 269.70 3 3
2 7 2005.64 51 11.96 3269 1994 2.24 / 271.69 3 3
3 13 1613.00 33 13.10 2662 1151 3.39 / 272.84 3 3
4 13 721.76 33 13.74 1410 639 4.03 / 273.48 3 3
5 8 -0.04 190 14.16 362 974 5.00 / 274.46 3 17
Average= 4.82 (KJ/cycle)

Cycle 55 GMT 19/10/2016 22:29: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 32 14.35 522 240 0.24 / 264.74 3 3
2 7 2003.60 50 11.97 3281 1964 2.20 / 266.71 3 3
3 13 1597.24 33 13.11 2649 1146 3.35 / 267.85 3 3
4 13 704.80 33 13.76 1371 623 3.97 / 268.47 3 3
5 8 0.32 190 14.16 364 979 4.95 / 269.45 3 16
Average= 4.81 (KJ/cycle)

Cycle 54 GMT 9/10/2016 22:38:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 32 14.35 525 241 0.24 / 259.76 3 3
2 7 2007.88 50 12.00 3298 1979 2.22 / 261.74 3 3
3 13 1598.52 33 13.10 2697 1166 3.39 / 262.91 3 3
4 13 700.36 33 13.77 1357 617 4.00 / 263.52 3 3
5 8 -0.16 190 14.16 364 979 4.98 / 264.50 3 14
Average= 4.81 (KJ/cycle)

Cycle 53 GMT 29/ 9/2016 22:59: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 32 14.37 526 242 0.24 / 254.39 3 3
2 7 2006.20 51 12.07 3263 2009 2.25 / 256.40 3 3
3 13 1806.60 33 12.96 2981 1275 3.53 / 257.67 3 3
4 13 859.08 33 13.66 1569 707 4.23 / 258.38 3 3
5 13 2.00 33 14.39 383 182 4.41 / 258.56 3 3
6 8 0.36 190 14.11 358 960 5.37 / 259.52 3 18
Average= 4.81 (KJ/cycle)

Cycle 52 GMT 19/ 9/2016 23:23: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 32 14.36 525 241 0.24 / 249.34 3 3
2 7 2007.72 51 12.10 3302 2038 2.28 / 251.38 3 3
3 13 1608.96 33 13.12 2677 1159 3.44 / 252.53 3 3
4 13 705.32 33 13.75 1387 629 4.07 / 253.16 3 3
5 8 -0.08 190 14.17 365 983 5.05 / 254.15 3 9
Average= 4.80 (KJ/cycle)

Cycle 51 GMT 9/ 9/2016 23:37: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 32 14.35 539 248 0.25 / 244.30 3 3
2 7 2000.84 51 12.18 3280 2037 2.28 / 246.34 3 3
3 13 1601.84 33 13.12 2661 1152 3.44 / 247.49 3 3
4 13 698.56 33 13.77 1379 627 4.06 / 248.11 3 3
5 8 0.04 190 14.17 365 983 5.05 / 249.10 3 11
Average= 4.79 (KJ/cycle)

Cycle 50 GMT 30/ 8/2016 23:54: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 32 14.38 523 241 0.24 / 239.34 3 3
2 7 2007.28 50 12.23 3294 2014 2.25 / 241.36 3 3
3 13 1430.92 33 13.25 2423 1059 3.31 / 242.42 3 3
4 13 749.72 33 13.73 1451 657 3.97 / 243.08 3 3
5 8 0.64 190 14.17 362 975 4.95 / 244.05 3 13
Average= 4.79 (KJ/cycle)

Cycle 49 GMT 21/ 8/2016 0: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 32 14.39 517 238 0.24 / 234.18 3 3
2 7 2000.76 50 12.33 3271 2017 2.25 / 236.19 3 3
3 13 1588.32 33 13.15 2645 1148 3.40 / 237.34 3 3
4 13 674.28 33 13.79 1341 610 4.01 / 237.95 3 3
5 13 16.36 33 14.39 404 192 4.20 / 238.14 3 3
6 8 0.00 190 14.14 358 962 5.17 / 239.10 3 17
Average= 4.78 (KJ/cycle)

Cycle 48 GMT 11/ 8/2016 0:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 32 14.40 522 241 0.24 / 229.33 3 3
2 7 2007.60 51 12.34 3268 2057 2.30 / 231.38 3 3
3 13 1409.48 33 13.26 2405 1052 3.35 / 232.44 3 3
4 13 556.24 33 13.89 1175 539 3.89 / 232.97 3 3
5 8 0.08 190 14.21 357 964 4.85 / 233.94 3 14
Average= 4.77 (KJ/cycle)

Cycle 47 GMT 1/ 8/2016 0:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 31 14.39 533 238 0.24 / 224.33 3 3
2 7 2005.12 51 12.38 3296 2081 2.32 / 226.41 3 3
3 13 1582.40 32 13.19 2639 1114 3.43 / 227.53 3 3
4 13 682.92 32 13.83 1336 591 4.02 / 228.12 3 3
5 8 0.08 190 14.20 359 969 4.99 / 229.09 3 13
Average= 4.77 (KJ/cycle)

Cycle 46 GMT 22/ 7/2016 0:36: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 31 14.42 526 235 0.24 / 219.36 3 3
2 7 2007.40 50 12.42 3299 2049 2.28 / 221.41 3 3
3 13 1588.68 32 13.19 2663 1124 3.41 / 222.53 3 3
4 13 684.84 32 13.83 1334 590 4.00 / 223.12 3 3
5 8 0.28 190 14.21 360 972 4.97 / 224.09 3 13
Average= 4.77 (KJ/cycle)

Cycle 45 GMT 12/ 7/2016 0:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 31 14.41 526 235 0.23 / 214.34 3 3
2 7 2002.52 51 12.46 3290 2091 2.33 / 216.44 3 3
3 13 1403.72 32 13.31 2381 1014 3.34 / 217.45 3 3
4 13 540.04 32 13.95 1141 509 3.85 / 217.96 3 3
5 13 23.80 32 14.41 412 190 4.04 / 218.15 3 3
6 8 -0.12 190 14.16 362 974 5.01 / 219.12 3 19
Average= 4.76 (KJ/cycle)

Cycle 44 GMT 2/ 7/2016 0:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 31 14.41 536 239 0.24 / 209.23 3 3
2 7 2002.44 50 12.49 3293 2056 2.30 / 211.28 3 3
3 13 1575.04 32 13.23 2597 1099 3.40 / 212.38 3 3
4 13 660.68 32 13.86 1309 581 3.98 / 212.96 3 3
5 13 16.52 32 14.42 407 188 4.16 / 213.15 3 3
6 8 0.20 190 14.15 356 957 5.12 / 214.11 3 16
Average= 4.76 (KJ/cycle)

Cycle 43 GMT 22/ 6/2016 1: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 31 14.41 532 238 0.24 / 204.04 3 3
2 7 2006.04 51 12.52 3281 2095 2.33 / 206.13 3 3
3 13 1580.20 32 13.22 2631 1113 3.45 / 207.24 3 3
4 13 671.24 32 13.85 1329 589 4.03 / 207.83 3 3
5 13 15.72 32 14.43 407 188 4.22 / 208.02 3 4
6 8 0.08 190 14.15 360 968 5.19 / 208.99 3 17
Average= 4.75 (KJ/cycle)

Cycle 42 GMT 12/ 6/2016 1:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 31 14.44 520 233 0.23 / 199.12 3 3
2 7 2001.76 50 12.56 3263 2049 2.28 / 201.17 3 3
3 13 1584.32 27 13.27 2687 963 3.24 / 202.13 3 3
4 13 713.88 27 13.86 1393 521 3.77 / 202.65 3 3
5 13 54.76 27 14.40 463 180 3.95 / 202.83 3 3
6 8 -0.08 190 14.17 358 964 4.91 / 203.80 3 16
Average= 4.74 (KJ/cycle)

Cycle 41 GMT 2/ 6/2016 1:14: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 31 14.43 527 236 0.24 / 194.09 3 3
2 7 2008.08 50 12.57 3281 2062 2.30 / 196.15 3 3
3 13 1583.48 27 13.28 2667 956 3.25 / 197.11 3 3
4 13 895.76 27 13.75 1634 607 3.86 / 197.72 3 3
5 13 88.52 27 14.37 521 202 4.06 / 197.92 3 3
6 8 0.28 190 14.20 360 971 5.03 / 198.89 3 12
Average= 4.74 (KJ/cycle)

Cycle 40 GMT 23/ 5/2016 1:29: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 31 14.44 532 238 0.24 / 189.21 3 3
2 7 2005.00 50 12.60 3282 2068 2.31 / 191.27 3 3
3 13 1409.76 27 13.40 2375 859 3.17 / 192.13 3 3
4 13 769.88 27 13.84 1470 549 3.71 / 192.68 3 3
5 13 68.52 27 14.41 489 190 3.90 / 192.87 3 3
6 8 0.00 190 14.20 364 982 4.89 / 193.85 3 15
Average= 4.73 (KJ/cycle)

Cycle 39 GMT 13/ 5/2016 1:16: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 31 14.47 516 231 0.23 / 184.29 3 3
2 7 2004.92 50 12.64 3255 2057 2.29 / 186.35 3 3
3 13 1568.16 27 13.33 2625 945 3.23 / 187.29 3 3
4 13 702.08 27 13.91 1371 515 3.75 / 187.81 3 3
5 13 58.64 27 14.43 475 185 3.93 / 187.99 3 3
6 8 0.24 190 14.21 361 975 4.91 / 188.97 3 15
Average= 4.72 (KJ/cycle)

Cycle 38 GMT 3/ 5/2016 1:22: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 31 14.45 517 232 0.23 / 179.40 3 3
2 7 2009.16 50 12.66 3260 2064 2.30 / 181.46 3 3
3 13 1412.56 27 13.43 2377 862 3.16 / 182.33 3 3
4 13 769.68 27 13.88 1489 558 3.72 / 182.88 3 3
5 13 66.52 27 14.43 481 187 3.90 / 183.07 3 3
6 8 0.08 190 14.21 366 988 4.89 / 184.06 3 11
Average= 4.72 (KJ/cycle)

Cycle 37 GMT 23/ 4/2016 1: 7: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 31 14.46 525 235 0.24 / 174.51 3 3
2 7 2002.52 50 12.70 3261 2071 2.31 / 176.58 3 3
3 13 1403.24 27 13.46 2371 862 3.17 / 177.44 3 3
4 13 754.80 27 13.90 1459 548 3.72 / 177.99 3 3
5 13 59.60 27 14.44 483 188 3.90 / 178.18 3 3
6 8 0.64 190 14.21 367 991 4.89 / 179.17 3 18
Average= 4.71 (KJ/cycle)

Cycle 36 GMT 13/ 4/2016 0:53: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 31 14.45 522 234 0.23 / 169.58 3 3
2 7 2007.16 51 12.73 3290 2136 2.37 / 171.72 3 3
3 13 1399.28 27 13.47 2373 863 3.23 / 172.58 3 3
4 13 755.36 27 13.92 1436 540 3.77 / 173.12 3 3
5 13 57.16 27 14.45 470 183 3.96 / 173.30 3 3
6 8 -0.36 190 14.19 360 971 4.93 / 174.27 3 16
Average= 4.71 (KJ/cycle)

Cycle 35 GMT 3/ 4/2016 0:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 31 14.45 522 234 0.23 / 164.63 3 3
2 7 2002.76 50 12.79 3251 2079 2.31 / 166.71 3 3
3 13 1577.68 27 13.40 2629 951 3.26 / 167.66 3 3
4 13 705.20 27 13.96 1372 517 3.78 / 168.18 3 3
5 13 60.92 27 14.45 487 190 3.97 / 168.37 3 3
6 8 0.20 190 14.22 362 978 4.95 / 169.35 3 15
Average= 4.70 (KJ/cycle)

Cycle 34 GMT 24/ 3/2016 0:40: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 31 14.47 532 239 0.24 / 159.63 3 3
2 7 2001.20 51 12.81 3296 2153 2.39 / 161.78 3 3
3 13 1567.48 27 13.42 2615 948 3.34 / 162.73 3 3
4 13 685.28 27 13.98 1350 510 3.85 / 163.24 3 3
5 13 45.68 27 14.48 455 178 4.03 / 163.42 3 3
6 8 0.16 190 14.20 364 982 5.01 / 164.40 3 18
Average= 4.70 (KJ/cycle)

Cycle 33 GMT 14/ 3/2016 0:44: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 31 14.46 533 239 0.24 / 154.65 3 3
2 7 2004.36 51 12.84 3314 2170 2.41 / 156.82 3 3
3 13 1377.92 27 13.54 2345 857 3.27 / 157.68 3 3
4 13 721.52 27 13.96 1412 532 3.80 / 158.21 3 3
5 13 51.48 27 14.47 469 183 3.98 / 158.40 3 3
6 8 0.04 190 14.20 368 993 4.97 / 159.39 3 14
Average= 4.69 (KJ/cycle)

Cycle 32 GMT 4/ 3/2016 0:52: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 31 14.46 537 241 0.24 / 149.56 3 3
2 7 2003.28 50 12.89 3279 2113 2.35 / 151.67 3 3
3 13 1580.76 27 13.42 2658 963 3.32 / 152.64 3 3
4 13 884.12 27 13.87 1638 613 3.93 / 153.25 3 3
5 13 40.68 27 14.50 448 175 4.11 / 153.42 3 3
6 8 0.24 190 14.21 367 991 5.10 / 154.42 3 13
Average= 4.68 (KJ/cycle)

Cycle 31 GMT 23/ 2/2016 1: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 31 14.48 524 235 0.24 / 144.72 3 3
2 7 2002.76 50 12.90 3308 2134 2.37 / 146.85 3 3
3 13 1385.80 25 13.59 2351 799 3.17 / 147.65 3 3
4 13 755.92 25 14.01 1444 506 3.67 / 148.15 3 3
5 13 36.84 25 14.51 452 164 3.84 / 148.32 3 3
6 8 0.04 190 14.22 370 1000 4.84 / 149.32 3 14
Average= 4.67 (KJ/cycle)

Cycle 30 GMT 13/ 2/2016 0:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 31 14.48 530 238 0.24 / 139.78 3 3
2 7 2004.36 50 12.93 3306 2137 2.38 / 141.92 3 3
3 13 1576.84 25 13.49 2625 885 3.26 / 142.80 3 3
4 13 717.08 25 14.03 1397 490 3.75 / 143.29 3 3
5 13 59.64 25 14.50 484 175 3.93 / 143.47 3 3
6 8 0.00 190 14.22 375 1013 4.94 / 144.48 3 14
Average= 4.66 (KJ/cycle)

Cycle 29 GMT 3/ 2/2016 0:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 31 14.47 529 237 0.24 / 134.83 3 3
2 7 2001.16 51 12.97 3266 2160 2.40 / 136.99 3 3
3 13 1568.68 25 13.50 2637 890 3.29 / 137.88 3 3
4 13 690.84 25 14.05 1378 484 3.77 / 138.37 3 3
5 13 55.24 25 14.51 476 173 3.94 / 138.54 3 3
6 8 0.24 190 14.22 371 1002 4.95 / 139.54 3 16
Average= 4.65 (KJ/cycle)

Cycle 28 GMT 24/ 1/2016 0:56: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 31 14.49 516 232 0.23 / 130.02 3 3
2 7 2002.56 50 12.99 3253 2113 2.34 / 132.13 3 3
3 13 1385.36 25 13.61 2334 794 3.14 / 132.93 3 3
4 13 751.44 25 14.02 1433 502 3.64 / 133.43 3 3
5 13 62.48 25 14.51 485 176 3.82 / 133.61 3 3
6 8 0.04 190 14.24 366 990 4.81 / 134.60 3 11
Average= 4.64 (KJ/cycle)

Cycle 27 GMT 14/ 1/2016 0:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 31 14.46 548 246 0.25 / 125.16 3 3
2 3 1020.28 1 14.45 1897 27 0.27 / 125.18 3 3
3 7 2005.24 50 12.99 3266 2121 2.39 / 127.30 3 3
4 13 1387.08 25 13.60 2355 801 3.20 / 128.11 3 3
5 13 744.20 25 14.02 1425 499 3.69 / 128.60 3 3
6 13 62.52 25 14.51 490 178 3.87 / 128.78 3 3
7 8 0.04 190 14.23 372 1006 4.88 / 129.79 3 14
Average= 4.64 (KJ/cycle)

Cycle 26 GMT 4/ 1/2016 0:42: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 32 14.44 556 257 0.26 / 120.25 3 3
2 3 973.20 -1 14.44 556 0 0.00 / 120.25 3 3
3 7 2006.44 50 13.01 3239 2107 2.36 / 122.36 3 3
4 13 1569.12 25 13.50 2600 877 3.24 / 123.24 3 3
5 13 707.48 25 14.03 1406 493 3.73 / 123.73 3 3
6 13 57.44 25 14.52 483 175 3.91 / 123.91 3 3
7 8 0.20 190 14.24 371 1004 4.91 / 124.91 3 15
Average= 4.63 (KJ/cycle)

Cycle 25 GMT 25/12/2015 0:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 32 14.47 528 244 0.24 / 115.38 3 3
2 7 2004.88 50 13.02 3255 2119 2.36 / 117.50 3 3
3 13 1390.36 25 13.61 2342 797 3.16 / 118.29 3 3
4 13 757.80 25 14.02 1454 510 3.67 / 118.80 3 3
5 13 69.68 25 14.51 498 181 3.85 / 118.98 3 3
6 8 0.04 190 14.24 374 1012 4.86 / 120.00 3 16
Average= 4.62 (KJ/cycle)

Cycle 24 GMT 15/12/2015 0:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 32 14.45 532 246 0.25 / 110.58 3 3
2 7 2002.28 50 13.05 3217 2099 2.35 / 112.68 3 3
3 13 1386.60 25 13.61 2332 793 3.14 / 113.47 3 3
4 13 738.16 25 14.04 1424 500 3.64 / 113.97 3 3
5 13 33.80 25 14.56 438 159 3.80 / 114.13 3 3
6 8 0.20 190 14.23 370 1000 4.80 / 115.13 3 16
Average= 4.61 (KJ/cycle)

Cycle 23 GMT 5/12/2015 0:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 32 14.45 533 246 0.25 / 105.69 3 3
2 7 2003.84 51 13.02 3283 2180 2.43 / 107.87 3 3
3 13 1382.16 25 13.61 2352 800 3.23 / 108.67 3 3
4 13 719.92 25 14.05 1407 494 3.72 / 109.16 3 3
5 13 30.12 25 14.55 445 162 3.88 / 109.32 3 3
6 8 0.00 190 14.22 375 1013 4.90 / 110.34 3 16
Average= 4.60 (KJ/cycle)

Cycle 22 GMT 25/11/2015 0:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 32 14.43 555 256 0.26 / 100.95 3 3
2 7 2002.28 51 13.04 3244 2157 2.41 / 103.11 3 3
3 13 1380.84 25 13.60 2354 800 3.21 / 103.91 3 3
4 13 731.84 25 14.04 1423 499 3.71 / 104.41 3 3
5 8 0.80 190 14.25 380 1029 4.74 / 105.44 3 14
Average= 4.58 (KJ/cycle)

Cycle 21 GMT 15/11/2015 0:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 32 14.46 537 248 0.25 / 96.08 3 3
2 7 2002.84 51 13.04 3272 2176 2.42 / 98.26 3 3
3 13 1376.36 25 13.61 2330 793 3.22 / 99.05 3 3
4 13 727.96 25 14.06 1394 490 3.71 / 99.54 3 3
5 13 26.56 25 14.56 423 154 3.86 / 99.69 3 3
6 8 -0.04 190 14.23 371 1003 4.86 / 100.70 3 18
Average= 4.58 (KJ/cycle)

Cycle 20 GMT 5/11/2015 0:22:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 32 14.46 540 250 0.25 / 91.21 3 3
2 7 2002.32 51 13.05 3262 2171 2.42 / 93.38 3 3
3 13 1387.96 25 13.62 2317 789 3.21 / 94.17 3 3
4 13 732.92 25 14.05 1405 494 3.70 / 94.66 3 3
5 13 58.56 25 14.54 472 172 3.87 / 94.84 3 3
6 8 0.36 190 14.26 368 997 4.87 / 95.83 3 16
Average= 4.56 (KJ/cycle)

Cycle 19 GMT 26/10/2015 0:18: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 32 14.48 532 247 0.25 / 86.28 3 3
2 7 2004.40 51 13.05 3278 2182 2.43 / 88.46 3 3
3 13 1368.00 25 13.61 2347 799 3.23 / 89.26 3 3
4 13 726.08 25 14.05 1413 496 3.72 / 89.76 3 3
5 13 59.52 25 14.54 485 176 3.90 / 89.93 3 3
6 8 -0.16 190 14.23 380 1027 4.93 / 90.96 3 13
Average= 4.55 (KJ/cycle)

Cycle 18 GMT 16/10/2015 0:18: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 32 14.45 536 248 0.25 / 81.39 3 3
2 7 2002.04 51 13.04 3299 2194 2.44 / 83.58 3 3
3 13 1363.16 25 13.63 2333 795 3.24 / 84.38 3 3
4 13 716.56 25 14.06 1395 490 3.73 / 84.87 3 3
5 13 47.32 25 14.56 457 166 3.89 / 85.03 3 3
6 8 0.28 190 14.23 370 1000 4.89 / 86.03 3 15
Average= 4.53 (KJ/cycle)

Cycle 17 GMT 6/10/2015 0:26: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 32 14.46 551 255 0.25 / 76.70 3 3
2 7 2001.84 50 13.05 3292 2148 2.40 / 78.85 3 3
3 13 1366.48 25 13.64 2298 784 3.19 / 79.64 3 3
4 13 714.72 25 14.07 1384 487 3.67 / 80.12 3 3
5 8 0.40 190 14.26 376 1019 4.69 / 81.14 3 12
Average= 4.51 (KJ/cycle)

Cycle 16 GMT 26/ 9/2015 0:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 32 14.47 535 248 0.25 / 71.82 3 3
2 7 2001.68 50 13.06 3275 2139 2.39 / 73.96 3 3
3 13 1378.80 25 13.63 2334 795 3.18 / 74.76 3 3
4 13 724.60 25 14.05 1408 495 3.68 / 75.25 3 3
5 13 59.12 25 14.55 487 177 3.85 / 75.43 3 3
6 8 -0.20 190 14.24 377 1020 4.87 / 76.45 3 14
Average= 4.50 (KJ/cycle)

Cycle 15 GMT 16/ 9/2015 0:15: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 32 14.49 541 251 0.25 / 66.98 3 3
2 7 2005.12 50 13.07 3234 2113 2.36 / 69.09 3 3
3 13 1377.64 25 13.63 2329 794 3.16 / 69.89 3 3
4 13 733.16 25 14.05 1424 500 3.66 / 70.39 3 3
5 13 15.08 25 14.58 426 155 3.81 / 70.54 3 3
6 8 0.28 190 14.18 383 1032 4.85 / 71.58 3 12
Average= 4.47 (KJ/cycle)

Cycle 14 GMT 6/ 9/2015 0: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 32 14.47 539 250 0.25 / 62.01 3 3
2 7 2003.32 51 13.06 3265 2175 2.42 / 64.19 3 3
3 13 1379.44 25 13.62 2353 801 3.23 / 64.99 3 3
4 13 736.76 25 14.04 1432 503 3.73 / 65.49 3 3
5 13 121.20 25 14.50 577 209 3.94 / 65.70 3 3
6 8 0.32 190 14.24 380 1028 4.97 / 66.73 3 12
Average= 4.45 (KJ/cycle)

Cycle 13 GMT 27/ 8/2015 0: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 32 14.47 550 255 0.25 / 57.08 3 3
2 7 2002.16 51 13.07 3241 2160 2.42 / 59.24 3 3
3 13 1359.20 25 13.63 2309 787 3.20 / 60.03 3 3
4 13 717.84 25 14.05 1404 493 3.69 / 60.52 3 3
5 13 50.76 25 14.56 481 175 3.87 / 60.70 3 3
6 8 -0.08 190 14.19 395 1065 4.94 / 61.76 3 16
Average= 4.41 (KJ/cycle)

Cycle 12 GMT 17/ 8/2015 0: 8: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 31 14.47 538 241 0.24 / 52.19 3 3
2 7 2003.48 50 13.06 3253 2124 2.37 / 54.32 3 3
3 13 1385.32 25 13.62 2335 795 3.16 / 55.11 3 3
4 13 739.76 25 14.05 1416 497 3.66 / 55.61 3 3
5 13 60.80 25 14.56 487 177 3.84 / 55.79 3 3
6 8 0.04 190 14.23 385 1041 4.88 / 56.83 3 15
Average= 4.37 (KJ/cycle)

Cycle 11 GMT 7/ 8/2015 0: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 31 14.46 549 246 0.25 / 47.27 3 3
2 7 2001.28 50 13.06 3256 2126 2.37 / 49.40 3 3
3 13 1382.68 25 13.63 2318 790 3.16 / 50.19 3 3
4 13 729.04 25 14.03 1424 499 3.66 / 50.69 3 3
5 13 119.80 25 14.50 582 211 3.87 / 50.90 3 3
6 8 0.08 190 14.22 391 1056 4.93 / 51.95 3 17
Average= 4.33 (KJ/cycle)

Cycle 10 GMT 27/ 7/2015 23:58: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 31 14.48 562 252 0.25 / 42.26 3 3
2 7 2003.44 50 13.05 3255 2124 2.38 / 44.39 3 3
3 13 1558.88 25 13.50 2619 884 3.26 / 45.27 3 3
4 13 698.52 25 14.05 1374 483 3.74 / 45.75 3 3
5 13 121.44 25 14.50 584 212 3.95 / 45.97 3 3
6 8 0.12 190 14.22 392 1059 5.01 / 47.02 3 13
Average= 4.27 (KJ/cycle)

Cycle 9 GMT 17/ 7/2015 23:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 31 14.46 561 251 0.25 / 37.30 3 3
2 7 2003.88 51 13.05 3240 2156 2.41 / 39.45 3 3
3 13 1366.96 25 13.60 2314 787 3.19 / 40.24 3 3
4 13 716.80 25 14.03 1400 491 3.69 / 40.73 3 3
5 13 128.20 25 14.49 595 216 3.90 / 40.95 3 3
6 8 0.00 190 14.22 394 1065 4.97 / 42.01 3 17
Average= 4.20 (KJ/cycle)

Cycle 8 GMT 7/ 7/2015 23:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 30 14.44 567 246 0.25 / 32.36 3 3
2 3 1028.28 1 14.54 1894 28 0.27 / 32.39 3 3
3 7 2002.52 50 13.00 3301 2146 2.42 / 34.53 3 3
4 13 1374.72 25 13.58 2342 795 3.21 / 35.33 3 3
5 13 706.84 25 14.02 1386 486 3.70 / 35.82 3 3
6 13 50.56 25 14.56 488 178 3.88 / 35.99 3 3
7 8 0.08 190 14.17 391 1053 4.93 / 37.05 3 12
Average= 4.12 (KJ/cycle)

Cycle 7 GMT 27/ 6/2015 23:47: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 30 14.46 553 240 0.24 / 27.66 3 3
2 7 2004.44 50 13.00 3263 2121 2.36 / 29.78 3 3
3 13 1361.72 25 13.55 2331 790 3.15 / 30.57 3 3
4 13 714.24 25 14.00 1407 492 3.64 / 31.06 3 3
5 8 0.64 190 14.22 390 1054 4.70 / 32.12 3 11
Average= 4.01 (KJ/cycle)

Cycle 6 GMT 17/ 6/2015 23:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 28 14.48 537 218 0.22 / 22.72 3 3
2 3 1037.08 1 14.54 1896 28 0.25 / 22.74 3 3
3 7 2004.60 51 12.94 3286 2169 2.41 / 24.91 3 3
4 13 1372.88 25 13.52 2348 794 3.21 / 25.71 3 3
5 13 723.64 25 13.97 1406 491 3.70 / 26.20 3 3
6 13 56.88 25 14.54 490 178 3.88 / 26.38 3 3
7 8 0.00 190 14.18 387 1043 4.92 / 27.42 3 15
Average= 3.92 (KJ/cycle)

Cycle 5 GMT 7/ 6/2015 23:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 24 14.48 552 192 0.19 / 17.89 3 3
2 10 1010.72 4 14.46 1861 108 0.30 / 17.99 3 3
3 3 1023.32 1 14.48 1883 27 0.33 / 18.02 3 3
4 7 2002.56 50 12.87 3314 2133 2.46 / 20.15 3 3
5 13 1374.12 25 13.46 2352 791 3.25 / 20.95 3 3
6 13 720.04 25 13.93 1413 492 3.74 / 21.44 3 3
7 8 0.40 190 14.18 394 1062 4.80 / 22.50 3 13
Average= 3.75 (KJ/cycle)

Cycle 4 GMT 28/ 5/2015 23: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 28 14.42 557 225 0.22 / 13.71 3 3
2 7 1503.88 51 13.22 2561 1727 1.95 / 15.44 3 3
3 13 1120.28 25 13.59 1983 674 2.63 / 16.11 3 3
4 13 481.52 25 14.08 1084 382 3.01 / 16.50 3 3
5 13 23.44 25 14.54 444 161 3.17 / 16.66 3 3
6 8 0.28 190 14.11 387 1038 4.21 / 17.70 3 14
Average= 3.54 (KJ/cycle)

Cycle 3 GMT 27/ 5/2015 23:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 29 14.37 562 234 0.23 / 9.22 3 3
2 3 970.64 -1 14.37 562 0 0.00 / 9.22 3 3
3 7 1506.00 74 12.92 2562 2449 2.68 / 11.67 3 3
4 13 797.96 20 13.84 1523 422 3.11 / 12.09 3 3
5 13 160.92 6 14.45 654 57 3.16 / 12.15 3 3
6 13 44.20 6 14.55 488 43 3.20 / 12.19 3 3
7 8 -0.16 240 14.08 384 1298 4.50 / 13.49 3 18
Average= 3.37 (KJ/cycle)

Cycle 2 GMT 27/ 5/2015 0:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 24 14.44 483 167 0.17 / 4.82 3 3
2 10 1041.32 3 14.23 1844 79 0.25 / 4.90 3 3
3 3 1059.68 2 14.25 1880 54 0.30 / 4.95 3 3
4 3 1019.76 1 14.19 1844 26 0.33 / 4.98 3 3
5 7 1515.96 74 12.74 2511 2367 2.69 / 7.35 3 3
6 13 799.68 20 13.78 1448 399 3.09 / 7.75 3 3
7 13 175.28 6 14.40 611 53 3.14 / 7.80 3 3
8 13 101.88 6 14.47 505 44 3.19 / 7.84 3 3
9 8 0.16 240 14.12 338 1145 4.33 / 8.99 3 21
Average= 3.00 (KJ/cycle)

Cycle 1 GMT 26/ 5/2015 0:51: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 27 14.48 456 178 0.18 / 1.73 3 3
2 3 1047.60 1 13.87 1825 25 0.20 / 1.76 3 3
3 3 1023.04 1 13.78 1841 25 0.23 / 1.78 3 3
4 7 1011.76 74 12.93 1761 1685 1.91 / 3.47 3 3
5 13 44.16 6 14.42 421 36 1.95 / 3.51 3 3
6 13 41.20 6 14.42 415 36 1.99 / 3.54 3 3
7 8 0.08 240 14.07 329 1111 3.10 / 4.65 3 26
Average= 2.33 (KJ/cycle)

Cycle 0 GMT 25/ 5/2015 13:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 89.24 26 14.27 436 162 0.16 / 0.16 3 3
2 7 95.92 74 14.07 429 447 0.61 / 0.61 3 3
3 8 0.08 240 14.25 277 947 1.56 / 1.56 3 96
Average= 1.56 (KJ/cycle)