Cycle 49 GMT 6/ 4/2025 23:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 43 14.65 403 254 0.25 / 221.85 2 3
2 3 1017.68 1 14.76 1661 25 0.28 / 221.88 2 5
3 3 1016.24 1 14.78 1672 25 0.30 / 221.90 2 4
4 8 2004.48 58 14.42 2849 2383 2.69 / 224.28 2 4
5 14 1481.32 16 14.48 2230 517 3.20 / 224.80 2 6
6 14 1156.08 16 14.53 1826 425 3.63 / 225.23 2 7
7 14 879.24 16 14.58 1461 341 3.97 / 225.57 2 8
8 14 635.12 16 14.62 1148 269 4.24 / 225.83 2 9
9 14 430.40 16 14.65 875 205 4.44 / 226.04 2 10
10 14 235.40 16 14.71 603 142 4.58 / 226.18 2 9
11 14 164.64 16 14.70 499 117 4.70 / 226.30 2 9
12 14 93.92 16 14.71 397 93 4.79 / 226.39 2 8
13 9 0.04 183 14.71 265 713 5.51 / 227.11 2 76
14 15 0.08 37 14.71 197 107 5.61 / 227.21 18 247
Average= 4.54
(KJ/cycle)

Cycle 48 GMT 27/ 3/2025 18:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 43 14.69 411 260 0.26 / 216.27 2 3
2 11 1017.72 2 14.76 1663 49 0.31 / 216.32 2 3
3 8 2005.84 58 14.43 2848 2384 2.69 / 218.70 2 4
4 14 1481.04 16 14.51 2225 517 3.21 / 219.22 2 7
5 14 1159.40 16 14.55 1828 426 3.63 / 219.65 2 7
6 14 880.64 16 14.60 1461 341 3.98 / 219.99 2 8
7 14 572.20 16 14.66 1060 249 4.22 / 220.24 2 9
8 14 381.48 16 14.71 803 189 4.41 / 220.42 2 9
9 14 225.84 16 14.72 587 138 4.55 / 220.56 2 9
10 14 152.08 16 14.73 482 114 4.67 / 220.68 2 8
11 14 120.72 16 14.71 439 103 4.77 / 220.78 2 9
12 9 -0.04 183 14.72 264 711 5.48 / 221.49 2 71
13 15 0.16 37 14.72 197 107 5.59 / 221.60 16 247
Average= 4.52
(KJ/cycle)

Cycle 47 GMT 17/ 3/2025 13:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 43 14.70 409 259 0.26 / 210.74 2 3
2 11 1013.48 2 14.78 1659 49 0.31 / 210.79 2 4
3 8 2010.88 58 14.42 2855 2388 2.70 / 213.18 2 4
4 14 1386.96 16 14.51 2110 490 3.19 / 213.67 2 8
5 14 1111.16 16 14.54 1761 410 3.59 / 214.07 2 7
6 14 917.44 16 14.56 1515 353 3.95 / 214.43 2 8
7 14 589.48 16 14.64 1085 254 4.20 / 214.68 2 9
8 14 361.48 16 14.69 779 183 4.39 / 214.86 2 9
9 14 212.56 16 14.71 567 133 4.52 / 215.00 2 8
10 14 141.00 16 14.71 465 109 4.63 / 215.11 2 8
11 14 73.12 16 14.72 368 87 4.71 / 215.19 2 7
12 9 0.00 183 14.72 264 711 5.43 / 215.91 2 90
13 15 -0.08 37 14.71 194 106 5.53 / 216.01 16 247
Average= 4.50
(KJ/cycle)

Cycle 46 GMT 7/ 3/2025 8:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 43 14.70 416 263 0.26 / 205.15 2 3
2 3 1021.72 1 14.79 1650 24 0.29 / 205.18 2 4
3 8 2005.76 58 14.44 2852 2389 2.68 / 207.57 2 5
4 14 1501.92 16 14.52 2259 525 3.20 / 208.09 2 6
5 14 1181.04 16 14.56 1861 434 3.63 / 208.53 2 7
6 14 789.64 16 14.64 1351 316 3.95 / 208.84 2 8
7 14 595.76 16 14.67 1100 258 4.21 / 209.10 2 9
8 14 409.12 16 14.70 844 199 4.41 / 209.30 2 9
9 14 249.72 16 14.71 624 147 4.55 / 209.45 2 9
10 14 173.36 16 14.72 512 121 4.67 / 209.57 2 8
11 14 110.00 16 14.73 419 99 4.77 / 209.66 2 8
12 9 0.24 183 14.74 262 707 5.48 / 210.37 2 60
13 15 -0.04 37 14.75 199 109 5.59 / 210.48 15 247
Average= 4.48
(KJ/cycle)

Cycle 45 GMT 25/ 2/2025 4: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 43 14.71 408 258 0.26 / 199.54 2 3
2 11 1000.08 2 14.79 1644 49 0.31 / 199.59 2 3
3 8 2007.48 58 14.47 2853 2394 2.70 / 201.98 2 5
4 14 1391.08 16 14.57 2122 495 3.20 / 202.48 2 6
5 14 1131.96 16 14.60 1795 419 3.62 / 202.90 2 7
6 14 930.04 16 14.62 1534 359 3.97 / 203.26 2 9
7 14 607.80 16 14.69 1106 260 4.23 / 203.52 2 9
8 14 410.52 16 14.72 843 199 4.43 / 203.72 2 9
9 14 250.80 16 14.74 627 148 4.58 / 203.86 2 9
10 14 141.16 16 14.75 467 110 4.69 / 203.97 2 8
11 14 110.60 16 14.76 424 100 4.79 / 204.07 2 8
12 9 0.24 183 14.74 263 709 5.50 / 204.78 2 70
13 15 -0.16 37 14.73 196 107 5.61 / 204.89 15 247
Average= 4.45
(KJ/cycle)

Cycle 44 GMT 14/ 2/2025 23:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 43 14.71 409 259 0.26 / 193.95 2 3
2 3 1021.20 1 14.82 1678 25 0.28 / 193.98 2 3
3 8 2010.52 58 14.47 2857 2398 2.68 / 196.37 2 4
4 14 1410.36 16 14.56 2155 502 3.18 / 196.88 2 6
5 14 1128.92 16 14.59 1790 418 3.60 / 197.29 2 8
6 14 865.32 16 14.63 1445 338 3.94 / 197.63 2 9
7 14 655.80 16 14.67 1175 276 4.22 / 197.91 2 9
8 14 407.56 16 14.72 840 198 4.41 / 198.10 2 10
9 14 250.32 16 14.73 619 146 4.56 / 198.25 2 9
10 14 175.92 16 14.74 515 121 4.68 / 198.37 2 8
11 14 99.48 16 14.74 406 96 4.78 / 198.47 2 8
12 9 0.16 183 14.75 262 707 5.48 / 199.18 2 59
13 15 0.00 37 14.75 199 109 5.59 / 199.28 15 247
Average= 4.43
(KJ/cycle)

Cycle 43 GMT 5/ 2/2025 6:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 43 14.73 412 261 0.26 / 188.34 2 3
2 11 1007.04 2 14.78 1647 49 0.31 / 188.39 2 3
3 8 2006.56 58 14.45 2844 2384 2.69 / 190.77 2 5
4 14 1480.96 16 14.51 2237 519 3.21 / 191.29 2 6
5 14 1117.80 16 14.57 1772 413 3.63 / 191.71 2 9
6 14 838.88 16 14.62 1412 330 3.96 / 192.04 2 8
7 14 680.32 16 14.63 1201 281 4.24 / 192.32 2 9
8 14 425.12 16 14.69 866 204 4.44 / 192.52 2 9
9 14 303.24 16 14.71 694 163 4.60 / 192.68 2 9
10 14 150.72 16 14.73 473 111 4.72 / 192.80 2 7
11 14 91.28 16 14.75 386 91 4.81 / 192.89 2 7
12 9 0.08 183 14.75 259 699 5.51 / 193.59 2 70
13 15 -0.04 37 14.76 194 106 5.61 / 193.69 16 247
Average= 4.40
(KJ/cycle)

Cycle 42 GMT 25/ 1/2025 18:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 43 14.73 404 256 0.26 / 182.72 2 3
2 3 1017.08 1 14.81 1661 25 0.28 / 182.74 2 4
3 8 2005.64 58 14.47 2865 2404 2.68 / 185.15 2 5
4 14 1468.32 16 14.53 2216 515 3.20 / 185.66 2 7
5 14 1144.28 16 14.59 1806 422 3.62 / 186.08 2 7
6 14 904.72 16 14.63 1500 351 3.97 / 186.44 2 8
7 14 616.64 16 14.68 1121 263 4.24 / 186.70 2 9
8 14 415.36 16 14.72 856 202 4.44 / 186.90 2 10
9 14 294.40 16 14.73 685 161 4.60 / 187.06 2 10
10 14 135.76 16 14.75 456 108 4.71 / 187.17 2 8
11 14 103.72 16 14.76 412 97 4.80 / 187.27 2 8
12 9 0.80 183 14.75 261 705 5.51 / 187.97 2 64
13 15 -0.08 37 14.75 200 109 5.62 / 188.08 14 247
Average= 4.37
(KJ/cycle)

Cycle 41 GMT 15/ 1/2025 13:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 43 14.74 403 255 0.26 / 177.07 2 3
2 3 1017.32 1 14.81 1668 25 0.28 / 177.09 2 4
3 8 2007.76 58 14.46 2865 2403 2.68 / 179.50 2 4
4 14 1379.40 16 14.56 2104 490 3.17 / 179.99 2 6
5 14 1223.44 16 14.57 1905 444 3.62 / 180.43 2 8
6 14 890.04 16 14.63 1476 346 3.96 / 180.78 2 9
7 14 641.40 16 14.67 1156 271 4.23 / 181.05 2 9
8 14 395.20 16 14.73 828 195 4.43 / 181.24 2 10
9 14 242.68 16 14.75 614 145 4.57 / 181.39 2 9
10 14 164.84 16 14.75 502 118 4.69 / 181.51 2 9
11 14 92.12 16 14.76 395 93 4.79 / 181.60 2 8
12 14 25.64 16 14.77 303 72 4.86 / 181.67 2 8
13 9 0.16 165 14.76 262 638 5.50 / 182.31 2 73
14 15 0.00 55 14.76 189 153 5.65 / 182.46 12 247
Average= 4.34
(KJ/cycle)

Cycle 40 GMT 5/ 1/2025 9:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 43 14.73 397 251 0.25 / 171.54 2 3
2 3 1021.12 1 14.81 1673 25 0.28 / 171.57 2 3
3 8 2005.92 58 14.47 2863 2403 2.68 / 173.97 2 4
4 14 1386.88 16 14.57 2112 492 3.17 / 174.46 2 6
5 14 1070.52 16 14.61 1716 401 3.57 / 174.86 2 7
6 14 832.88 16 14.65 1404 329 3.90 / 175.19 2 9
7 14 632.84 16 14.68 1145 269 4.17 / 175.46 2 9
8 14 392.64 16 14.73 826 195 4.37 / 175.66 2 10
9 14 236.08 16 14.75 605 143 4.51 / 175.80 2 9
10 14 118.76 16 14.76 435 103 4.61 / 175.90 2 8
11 14 85.84 16 14.77 394 93 4.70 / 176.00 2 9
12 9 0.04 180 14.78 263 700 5.40 / 176.69 2 70
13 15 0.08 40 14.77 201 119 5.52 / 176.81 14 247
Average= 4.31
(KJ/cycle)

Cycle 39 GMT 26/12/2024 4:42:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 43 14.71 407 257 0.26 / 166.01 2 3
2 8 2006.60 58 14.46 2857 2396 2.65 / 168.40 2 6
3 14 1392.28 16 14.55 2121 494 3.15 / 168.90 2 6
4 14 1237.16 16 14.55 1927 449 3.60 / 169.34 2 8
5 14 860.60 16 14.63 1444 338 3.93 / 169.68 2 8
6 14 577.80 16 14.69 1072 252 4.19 / 169.93 2 10
7 14 414.28 16 14.72 850 200 4.39 / 170.13 2 10
8 14 249.96 16 14.74 624 147 4.53 / 170.28 2 9
9 14 136.88 16 14.77 460 109 4.64 / 170.39 2 8
10 14 75.08 16 14.76 375 89 4.73 / 170.48 2 8
11 9 0.00 183 14.76 261 705 5.44 / 171.18 2 79
12 15 0.00 37 14.76 196 107 5.54 / 171.29 15 247
Average= 4.28
(KJ/cycle)

Cycle 38 GMT 15/12/2024 23:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 43 14.73 416 263 0.26 / 160.36 2 3
2 3 1023.36 1 14.80 1664 25 0.29 / 160.39 2 5
3 8 2005.80 58 14.47 2866 2405 2.69 / 162.79 2 4
4 14 1550.36 16 14.53 2318 539 3.23 / 163.33 2 7
5 14 1096.84 16 14.60 1744 407 3.64 / 163.74 2 7
6 14 831.72 16 14.64 1399 328 3.97 / 164.07 2 9
7 14 589.72 16 14.70 1088 256 4.22 / 164.32 2 9
8 14 466.48 16 14.71 924 217 4.44 / 164.54 2 9
9 14 216.84 16 14.75 579 137 4.58 / 164.68 2 9
10 14 150.80 16 14.77 483 114 4.69 / 164.79 2 9
11 14 79.96 16 14.76 380 90 4.78 / 164.88 2 8
12 14 48.08 16 14.75 335 79 4.86 / 164.96 2 8
13 9 0.20 165 14.77 260 634 5.49 / 165.59 2 58
14 15 0.04 55 14.76 192 156 5.65 / 165.75 12 247
Average= 4.25
(KJ/cycle)

Cycle 37 GMT 6/12/2024 7:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 43 14.70 399 252 0.25 / 154.73 3 3
2 3 1016.28 1 14.83 1678 25 0.28 / 154.76 2 4
3 8 2006.44 59 14.46 2847 2429 2.71 / 157.19 2 5
4 14 1391.12 16 14.56 2110 492 3.20 / 157.68 2 6
5 14 1187.24 16 14.57 1868 435 3.63 / 158.11 2 8
6 14 872.52 16 14.63 1450 339 3.97 / 158.45 2 9
7 14 587.28 16 14.69 1083 255 4.23 / 158.71 2 9
8 14 387.16 16 14.73 817 193 4.42 / 158.90 2 10
9 14 197.08 16 14.76 552 130 4.55 / 159.03 2 9
10 14 127.64 16 14.77 453 107 4.66 / 159.14 2 9
11 14 69.96 16 14.78 365 86 4.74 / 159.22 2 8
12 14 40.56 16 14.76 326 77 4.82 / 159.30 2 8
13 9 -0.04 165 14.77 265 646 5.47 / 159.95 2 92
14 15 0.00 55 14.77 189 154 5.62 / 160.10 14 247
Average= 4.21
(KJ/cycle)

Cycle 36 GMT 25/11/2024 18:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 43 14.73 402 255 0.25 / 149.10 2 3
2 3 1018.24 1 14.81 1679 25 0.28 / 149.12 2 4
3 3 1017.84 1 14.82 1662 25 0.30 / 149.15 2 4
4 8 2005.44 59 14.50 2856 2443 2.75 / 151.59 2 4
5 14 1343.28 16 14.61 2046 478 3.23 / 152.07 2 7
6 14 1185.48 16 14.60 1863 435 3.66 / 152.50 2 7
7 14 809.40 16 14.68 1373 322 3.98 / 152.83 2 8
8 14 547.92 16 14.73 1031 243 4.23 / 153.07 2 10
9 14 424.80 16 14.75 868 205 4.43 / 153.27 2 10
10 14 217.52 16 14.78 586 139 4.57 / 153.41 2 10
11 14 144.96 16 14.78 476 113 4.68 / 153.52 2 9
12 14 77.20 16 14.80 379 90 4.77 / 153.61 2 8
13 14 21.56 16 14.79 297 70 4.84 / 153.68 2 8
14 9 0.08 163 14.78 263 634 5.48 / 154.32 2 58
15 15 0.08 57 14.78 191 161 5.64 / 154.48 14 247
Average= 4.18
(KJ/cycle)

Cycle 35 GMT 15/11/2024 13:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 43 14.73 411 260 0.26 / 143.58 3 3
2 3 1021.00 1 14.81 1676 25 0.29 / 143.61 2 4
3 8 2008.68 58 14.49 2860 2404 2.69 / 146.01 2 5
4 14 1484.76 16 14.56 2231 520 3.21 / 146.53 2 6
5 14 1073.40 16 14.64 1720 403 3.61 / 146.93 2 8
6 14 834.80 16 14.67 1407 330 3.94 / 147.26 2 9
7 14 593.16 16 14.72 1089 256 4.20 / 147.52 2 9
8 14 386.16 16 14.75 815 192 4.39 / 147.71 2 10
9 14 190.24 16 14.77 544 129 4.52 / 147.84 2 9
10 14 124.04 16 14.78 443 105 4.62 / 147.95 2 9
11 14 56.52 16 14.78 347 82 4.71 / 148.03 2 8
12 9 0.08 178 14.78 262 689 5.40 / 148.72 2 53
13 15 -0.12 42 14.78 201 125 5.52 / 148.84 13 247
Average= 4.13
(KJ/cycle)

Cycle 34 GMT 5/11/2024 9:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 43 14.72 403 255 0.26 / 138.05 2 3
2 11 1006.56 2 14.81 1652 49 0.30 / 138.10 2 3
3 8 2005.04 58 14.49 2857 2401 2.71 / 140.50 2 5
4 14 1401.52 16 14.58 2122 495 3.20 / 141.00 2 6
5 14 1242.60 16 14.59 1935 452 3.65 / 141.45 2 7
6 14 783.76 16 14.67 1342 315 3.97 / 141.76 2 9
7 14 547.92 16 14.72 1032 243 4.21 / 142.01 2 10
8 14 314.40 16 14.76 719 170 4.38 / 142.18 2 10
9 14 206.76 16 14.78 567 134 4.51 / 142.31 2 9
10 14 135.28 16 14.79 462 109 4.62 / 142.42 2 9
11 14 61.72 16 14.80 356 84 4.71 / 142.50 2 8
12 9 0.52 178 14.78 264 695 5.40 / 143.20 2 57
13 15 0.04 42 14.78 201 125 5.53 / 143.32 12 247
Average= 4.09
(KJ/cycle)

Cycle 33 GMT 26/10/2024 4:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 43 14.76 400 254 0.25 / 132.39 2 3
2 11 1004.96 2 14.83 1672 50 0.30 / 132.44 2 3
3 3 970.40 -1 15.21 4 0 0.05 / 132.44 2 3
4 8 2005.64 58 14.50 2864 2409 2.71 / 134.85 2 5
5 14 1389.32 16 14.58 2113 493 3.21 / 135.34 2 7
6 14 1106.16 16 14.62 1761 412 3.62 / 135.76 2 8
7 14 908.56 16 14.65 1508 353 3.97 / 136.11 2 8
8 14 619.92 16 14.71 1125 265 4.24 / 136.37 2 10
9 14 410.88 16 14.73 849 200 4.44 / 136.57 2 10
10 14 241.64 16 14.77 621 147 4.58 / 136.72 2 10
11 14 128.12 16 14.78 452 107 4.69 / 136.83 2 9
12 14 66.24 16 14.80 365 86 4.78 / 136.91 2 8
13 14 38.20 16 14.79 325 77 4.85 / 136.99 2 9
14 9 0.12 165 14.78 266 649 5.50 / 137.64 2 89
15 15 -0.12 55 14.78 192 156 5.66 / 137.80 14 247
Average= 4.05
(KJ/cycle)

Cycle 32 GMT 15/10/2024 23:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 43 14.77 419 266 0.27 / 126.83 2 3
2 3 1018.80 1 14.84 1671 25 0.29 / 126.85 2 3
3 8 2007.52 58 14.53 2874 2422 2.71 / 129.28 2 5
4 14 1308.00 16 14.64 2016 472 3.19 / 129.75 2 6
5 14 1110.12 16 14.65 1771 415 3.60 / 130.16 2 8
6 14 787.40 16 14.71 1343 316 3.92 / 130.48 2 9
7 14 518.48 16 14.77 996 235 4.15 / 130.72 2 9
8 14 402.36 16 14.78 842 199 4.35 / 130.91 2 10
9 14 200.60 16 14.83 561 133 4.48 / 131.05 2 9
10 14 133.92 16 14.82 464 110 4.59 / 131.16 2 9
11 14 100.48 16 14.82 419 99 4.69 / 131.26 2 9
12 14 31.20 16 14.80 315 75 4.77 / 131.33 2 8
13 9 0.08 163 14.81 267 645 5.41 / 131.98 2 63
14 15 0.08 57 14.82 193 163 5.58 / 132.14 15 247
Average= 4.00
(KJ/cycle)

Cycle 31 GMT 5/10/2024 19:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 43 14.77 410 260 0.26 / 121.16 2 3
2 3 1020.40 1 14.86 1672 25 0.29 / 121.18 2 5
3 8 2009.12 58 14.52 2870 2417 2.70 / 123.60 2 4
4 14 1394.12 16 14.62 2125 497 3.20 / 124.10 2 7
5 14 1151.72 16 14.64 1825 427 3.63 / 124.52 2 8
6 14 866.88 16 14.68 1454 342 3.97 / 124.87 2 8
7 14 556.20 16 14.75 1045 247 4.21 / 125.11 2 9
8 14 404.68 16 14.77 845 200 4.41 / 125.31 2 10
9 14 279.20 16 14.79 674 159 4.57 / 125.47 2 10
10 14 126.64 16 14.81 453 107 4.68 / 125.58 2 9
11 14 94.04 16 14.81 416 99 4.78 / 125.68 2 9
12 14 29.52 16 14.81 317 75 4.86 / 125.75 2 8
13 9 0.08 163 14.80 268 647 5.50 / 126.40 2 56
14 15 -0.04 57 14.80 194 164 5.67 / 126.56 13 247
Average= 3.96
(KJ/cycle)

Cycle 30 GMT 26/ 9/2024 2:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 43 14.75 411 261 0.26 / 115.52 2 3
2 11 1006.48 2 14.80 1649 49 0.31 / 115.57 2 4
3 8 2006.52 59 14.52 2861 2451 2.76 / 118.02 2 5
4 14 1467.00 16 14.60 2229 521 3.28 / 118.54 2 6
5 14 1149.16 16 14.64 1817 426 3.71 / 118.97 2 7
6 14 906.72 16 14.67 1505 353 4.06 / 119.32 2 9
7 14 553.08 16 14.74 1044 246 4.31 / 119.57 2 9
8 14 362.24 16 14.78 784 185 4.49 / 119.75 2 10
9 14 215.48 16 14.80 578 137 4.63 / 119.89 2 9
10 14 146.08 16 14.80 472 112 4.74 / 120.00 2 8
11 14 74.36 16 14.81 367 87 4.83 / 120.09 2 8
12 9 0.04 178 14.82 260 686 5.51 / 120.78 2 54
13 15 -0.08 42 14.81 196 122 5.64 / 120.90 13 247
Average= 3.90
(KJ/cycle)

Cycle 29 GMT 15/ 9/2024 22:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 43 14.73 416 263 0.26 / 109.91 3 3
2 8 2004.64 58 14.53 2864 2414 2.68 / 112.32 2 6
3 14 1431.04 16 14.62 2178 509 3.19 / 112.83 2 7
4 14 1114.96 16 14.66 1774 416 3.60 / 113.25 2 7
5 14 914.12 16 14.69 1515 356 3.96 / 113.60 2 9
6 14 586.44 16 14.75 1086 256 4.22 / 113.86 2 10
7 14 376.40 16 14.78 808 191 4.41 / 114.05 2 10
8 14 219.96 16 14.79 582 138 4.54 / 114.19 2 10
9 14 148.20 16 14.81 481 114 4.66 / 114.30 2 9
10 14 78.52 16 14.81 378 90 4.75 / 114.39 2 8
11 14 22.20 16 14.82 301 71 4.82 / 114.46 2 8
12 9 0.04 163 14.81 265 640 5.46 / 115.10 2 63
13 15 -0.12 57 14.81 188 159 5.62 / 115.26 13 247
Average= 3.84
(KJ/cycle)

Cycle 28 GMT 5/ 9/2024 17:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 43 14.79 407 259 0.26 / 104.10 2 3
2 3 1022.68 1 14.85 1677 25 0.28 / 104.12 2 4
3 3 1019.44 1 14.86 1682 25 0.31 / 104.15 2 4
4 8 2006.04 58 14.54 2856 2409 2.72 / 106.56 2 6
5 14 1498.84 16 14.61 2255 527 3.24 / 107.08 2 7
6 14 1347.60 16 14.61 2068 483 3.73 / 107.57 2 9
7 14 918.64 16 14.68 1523 358 4.09 / 107.92 2 9
8 14 661.48 16 14.72 1185 279 4.36 / 108.20 2 10
9 14 439.68 16 14.76 890 210 4.57 / 108.41 2 10
10 14 226.08 16 14.80 594 141 4.72 / 108.55 2 10
11 14 151.84 16 14.81 491 116 4.83 / 108.67 2 9
12 14 85.40 16 14.81 392 93 4.92 / 108.76 2 9
13 14 30.92 16 14.82 316 75 5.00 / 108.84 2 8
14 9 0.60 165 14.81 267 652 5.65 / 109.49 2 82
15 15 -0.04 55 14.82 191 156 5.81 / 109.65 14 247
Average= 3.78
(KJ/cycle)

Cycle 27 GMT 26/ 8/2024 13:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 43 14.81 400 255 0.25 / 98.44 2 3
2 8 2004.80 58 14.53 2855 2406 2.66 / 100.84 2 4
3 14 1458.36 16 14.60 2212 517 3.18 / 101.36 2 7
4 14 1084.48 16 14.66 1747 410 3.59 / 101.77 2 7
5 14 886.28 16 14.68 1485 349 3.94 / 102.12 2 8
6 14 635.76 16 14.73 1158 273 4.21 / 102.39 2 9
7 14 385.40 16 14.77 817 193 4.40 / 102.58 2 10
8 14 262.60 16 14.79 653 155 4.56 / 102.74 2 10
9 14 185.76 16 14.80 542 128 4.68 / 102.87 2 10
10 14 81.44 16 14.81 385 91 4.78 / 102.96 2 8
11 14 24.64 16 14.81 307 73 4.85 / 103.03 2 7
12 9 0.20 165 14.81 267 652 5.50 / 103.68 2 100
13 15 -0.12 55 14.82 190 155 5.66 / 103.84 16 247
Average= 3.71
(KJ/cycle)

Cycle 26 GMT 16/ 8/2024 21: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 43 14.80 405 258 0.26 / 92.84 2 3
2 8 2007.72 59 14.55 2864 2459 2.72 / 95.30 2 6
3 14 1435.56 16 14.63 2177 510 3.23 / 95.81 2 7
4 14 1123.16 16 14.67 1790 420 3.65 / 96.23 2 7
5 14 845.84 16 14.72 1422 335 3.98 / 96.57 2 9
6 14 555.92 16 14.78 1046 247 4.23 / 96.81 2 9
7 14 395.88 16 14.80 827 196 4.42 / 97.01 2 10
8 14 234.16 16 14.83 605 144 4.57 / 97.15 2 10
9 14 156.80 16 14.84 495 118 4.69 / 97.27 2 9
10 14 86.68 16 14.84 390 93 4.78 / 97.36 2 9
11 9 0.08 178 14.83 264 697 5.47 / 98.06 2 58
12 15 0.00 42 14.82 197 123 5.60 / 98.18 11 247
Average= 3.64
(KJ/cycle)

Cycle 25 GMT 6/ 8/2024 8:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 43 14.72 404 256 0.26 / 87.31 2 3
2 8 2008.00 58 14.56 2857 2413 2.67 / 89.72 2 5
3 14 1410.68 16 14.64 2143 502 3.17 / 90.22 2 6
4 14 1137.16 16 14.67 1803 423 3.59 / 90.65 2 7
5 14 893.32 16 14.70 1488 350 3.94 / 91.00 2 8
6 14 523.12 16 14.76 1001 236 4.18 / 91.23 2 9
7 14 366.12 16 14.80 787 186 4.37 / 91.42 2 10
8 14 211.44 16 14.83 576 137 4.50 / 91.56 2 9
9 14 140.80 16 14.83 472 112 4.61 / 91.67 2 9
10 14 68.96 16 14.83 370 88 4.70 / 91.76 2 8
11 9 0.64 180 14.82 267 712 5.42 / 92.47 2 86
12 15 -0.08 40 14.81 194 115 5.53 / 92.58 16 247
Average= 3.56
(KJ/cycle)

Cycle 24 GMT 27/ 7/2024 3:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 43 14.74 400 254 0.25 / 79.82 2 3
2 8 1908.64 150 14.33 2753 5918 6.17 / 85.74 2 5
3 14 312.84 16 14.71 711 167 6.34 / 85.91 2 9
4 14 227.00 16 14.72 603 142 6.48 / 86.05 2 9
5 14 146.44 16 14.71 483 114 6.59 / 86.16 2 8
6 14 59.96 16 14.73 359 85 6.68 / 86.25 2 7
7 9 0.12 172 14.72 266 673 7.35 / 86.92 2 67
8 15 -0.04 48 14.72 191 135 7.49 / 87.05 11 247
Average= 3.48
(KJ/cycle)

Cycle 23 GMT 26/ 7/2024 17:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 44 14.76 391 254 0.25 / 72.90 2 3
2 3 972.20 -1 15.18 4 0 0.00 / 72.90 2 3
3 8 1724.12 150 14.42 2509 5427 5.68 / 78.32 2 4
4 14 266.48 16 14.76 647 153 5.83 / 78.48 2 9
5 14 186.84 16 14.75 535 126 5.96 / 78.60 2 8
6 14 108.44 16 14.76 421 99 6.06 / 78.70 2 7
7 14 33.56 16 14.77 314 74 6.13 / 78.77 2 7
8 9 0.56 168 14.76 261 647 6.78 / 79.42 2 68
9 15 -0.08 52 14.76 189 145 6.93 / 79.57 14 247
Average= 3.32
(KJ/cycle)

Cycle 22 GMT 26/ 7/2024 8: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 44 14.75 404 262 0.26 / 66.83 2 3
2 3 967.68 -1 15.18 4 0 0.00 / 66.83 2 3
3 8 1436.12 150 14.52 2150 4683 4.94 / 71.52 2 5
4 14 209.12 16 14.76 558 132 5.08 / 71.65 2 8
5 14 134.24 16 14.77 457 108 5.18 / 71.76 2 7
6 14 52.84 16 14.78 340 80 5.27 / 71.84 2 6
7 9 0.04 176 14.78 261 679 5.94 / 72.52 2 63
8 15 -0.08 44 14.77 193 125 6.07 / 72.64 14 247
Average= 3.16
(KJ/cycle)

Cycle 21 GMT 25/ 7/2024 23:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 45 14.80 392 261 0.26 / 60.75 3 3
2 3 949.08 -1 15.20 4 0 0.00 / 60.75 3 3
3 3 967.60 -1 15.21 4 0 0.00 / 60.75 3 3
4 8 1414.44 151 14.54 2127 4670 4.93 / 65.42 2 5
5 14 219.40 16 14.75 585 138 5.07 / 65.56 2 8
6 14 134.44 16 14.78 466 110 5.18 / 65.67 2 8
7 14 56.76 16 14.78 352 83 5.26 / 65.76 2 7
8 9 0.12 176 14.79 265 690 5.95 / 66.45 2 69
9 15 0.16 44 14.78 195 127 6.08 / 66.57 13 247
Average= 3.03
(KJ/cycle)

Cycle 20 GMT 25/ 7/2024 15:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 38 14.81 393 221 0.22 / 55.84 2 3
2 3 731.20 -5 15.14 4 0 0.00 / 55.84 2 3
3 3 875.80 -2 15.16 4 0 0.00 / 55.84 2 3
4 8 1127.76 150 14.64 1736 3812 4.03 / 59.65 2 6
5 14 34.60 16 14.83 299 71 4.10 / 59.73 2 5
6 9 0.08 172 14.83 249 635 4.74 / 60.36 2 64
7 15 -0.12 48 14.82 186 132 4.87 / 60.49 13 247
Average= 2.88
(KJ/cycle)

Cycle 19 GMT 25/ 7/2024 11:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 41 14.84 403 245 0.25 / 50.90 2 3
2 3 713.68 -5 15.16 4 0 0.00 / 50.90 2 3
3 3 846.56 -3 15.20 5 0 0.00 / 50.90 2 3
4 8 1135.12 150 14.67 1749 3849 4.09 / 54.75 2 5
5 14 25.48 16 14.86 295 70 4.16 / 54.82 2 6
6 9 0.04 170 14.85 260 656 4.82 / 55.48 2 68
7 15 -0.04 50 14.84 193 143 4.96 / 55.62 15 247
Average= 2.78
(KJ/cycle)

Cycle 18 GMT 25/ 7/2024 7:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 45 14.82 392 261 0.26 / 45.96 3 3
2 3 690.24 -6 15.15 4 0 0.00 / 45.96 3 3
3 3 817.04 -3 15.18 4 0 0.00 / 45.96 3 3
4 8 1129.08 150 14.69 1739 3832 4.09 / 49.79 2 5
5 14 47.96 16 14.86 328 78 4.17 / 49.87 2 6
6 9 0.12 168 14.86 258 644 4.82 / 50.51 2 56
7 15 0.00 52 14.85 189 146 4.96 / 50.66 13 247
Average= 2.67
(KJ/cycle)

Cycle 17 GMT 25/ 7/2024 3:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 69 14.86 402 412 0.41 / 42.12 3 3
2 3 382.64 -2 15.12 4 0 0.00 / 42.12 3 3
3 3 462.24 -1 15.16 4 0 0.00 / 42.12 3 3
4 8 691.68 150 14.84 1186 2640 3.05 / 44.76 2 5
5 14 133.00 16 14.88 429 102 3.15 / 44.86 2 4
6 14 44.80 16 14.89 311 74 3.23 / 44.94 2 4
7 9 0.12 176 14.89 244 639 3.87 / 45.57 2 68
8 15 0.12 44 14.88 185 121 3.99 / 45.70 13 246
Average= 2.54
(KJ/cycle)

Cycle 16 GMT 24/ 7/2024 23:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 70 14.90 387 404 0.40 / 38.21 3 3
2 3 375.52 -2 15.14 5 0 0.00 / 38.21 3 3
3 3 456.24 -1 15.19 4 0 0.00 / 38.21 3 3
4 8 664.84 150 14.87 1146 2556 2.96 / 40.77 2 3
5 14 118.76 16 14.91 412 98 3.06 / 40.86 2 4
6 14 36.48 16 14.91 302 72 3.13 / 40.94 2 4
7 9 0.16 176 14.91 247 648 3.78 / 41.58 2 58
8 15 0.24 44 14.91 187 123 3.90 / 41.71 14 246
Average= 2.45
(KJ/cycle)

Cycle 15 GMT 24/ 7/2024 20:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 103 14.90 398 611 0.61 / 36.13 3 3
2 8 197.24 150 14.95 473 1061 1.67 / 37.19 3 5
3 9 -0.04 99 14.95 225 333 2.00 / 37.53 3 94
4 15 0.00 121 14.95 155 280 2.28 / 37.81 18 246
Average= 2.36
(KJ/cycle)

Cycle 14 GMT 24/ 7/2024 18:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 103 14.89 394 604 0.60 / 33.83 3 3
2 8 203.44 150 14.94 482 1080 1.68 / 34.91 3 4
3 9 -0.08 101 14.94 224 338 2.02 / 35.24 3 85
4 15 -0.08 119 14.94 156 277 2.30 / 35.52 18 246
Average= 2.37
(KJ/cycle)

Cycle 13 GMT 24/ 7/2024 17:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 103 14.89 395 606 0.61 / 31.52 3 3
2 8 207.64 150 14.94 488 1094 1.70 / 32.61 3 4
3 9 0.08 101 14.94 223 336 2.04 / 32.95 3 146
4 15 -0.04 119 14.95 155 276 2.31 / 33.22 19 246
Average= 2.37
(KJ/cycle)

Cycle 12 GMT 24/ 7/2024 16:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 103 14.89 391 600 0.60 / 29.19 3 3
2 8 214.24 150 14.93 496 1111 1.71 / 30.30 3 4
3 9 0.00 99 14.94 224 331 2.04 / 30.63 3 54
4 15 -0.04 121 14.94 155 280 2.32 / 30.91 12 246
Average= 2.38
(KJ/cycle)

Cycle 11 GMT 24/ 7/2024 15:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 103 14.88 398 610 0.61 / 26.85 3 3
2 8 214.72 150 14.93 501 1122 1.73 / 27.98 3 4
3 9 0.08 101 14.92 226 341 2.07 / 28.32 3 111
4 15 0.04 119 14.92 153 272 2.34 / 28.59 18 246
Average= 2.38
(KJ/cycle)

Cycle 10 GMT 24/ 7/2024 13:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 103 14.86 397 608 0.61 / 24.51 3 3
2 8 214.20 150 14.93 499 1118 1.73 / 25.63 3 4
3 9 -0.08 101 14.92 227 342 2.07 / 25.97 3 87
4 15 0.08 119 14.93 154 274 2.34 / 26.24 17 246
Average= 2.39
(KJ/cycle)

Cycle 9 GMT 24/ 7/2024 12:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 103 14.87 402 616 0.62 / 22.17 3 3
2 8 212.84 150 14.93 500 1120 1.74 / 23.29 3 4
3 9 0.00 101 14.92 226 341 2.08 / 23.63 3 62
4 15 -0.04 119 14.93 156 277 2.35 / 23.90 18 246
Average= 2.39
(KJ/cycle)

Cycle 8 GMT 24/ 7/2024 11:33:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 103 14.86 390 597 0.60 / 19.84 3 3
2 8 207.60 150 14.92 489 1094 1.69 / 20.93 3 5
3 9 0.00 103 14.92 226 347 2.04 / 21.28 3 169
4 15 -0.04 117 14.93 155 271 2.31 / 21.55 22 246
Average= 2.39
(KJ/cycle)

Cycle 7 GMT 24/ 7/2024 10:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 103 14.84 401 613 0.61 / 17.52 3 3
2 8 205.72 150 14.91 494 1105 1.72 / 18.62 3 4
3 9 0.04 101 14.91 228 343 2.06 / 18.96 3 53
4 15 -0.04 119 14.91 156 277 2.34 / 19.24 15 246
Average= 2.41
(KJ/cycle)

Cycle 6 GMT 24/ 7/2024 9: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 103 14.83 393 600 0.60 / 14.98 3 3
2 11 255.64 2 14.91 569 17 0.62 / 14.99 3 3
3 8 255.88 150 14.88 565 1261 1.88 / 16.26 3 4
4 9 0.08 118 14.89 230 404 2.28 / 16.66 3 57
5 15 0.08 102 14.89 160 243 2.53 / 16.90 16 246
Average= 2.41
(KJ/cycle)

Cycle 5 GMT 24/ 7/2024 7:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 103 14.81 401 612 0.61 / 12.36 3 3
2 11 272.44 3 14.92 620 28 0.64 / 12.39 3 3
3 8 277.20 150 14.87 594 1325 1.96 / 13.71 3 4
4 9 0.04 125 14.88 232 432 2.40 / 14.14 3 56
5 15 -0.08 95 14.87 166 234 2.63 / 14.38 19 246
Average= 2.40
(KJ/cycle)

Cycle 4 GMT 24/ 7/2024 6:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 103 14.82 402 614 0.61 / 9.75 3 3
2 11 270.16 3 14.92 614 27 0.64 / 9.78 3 3
3 8 274.00 150 14.87 589 1314 1.95 / 11.09 3 4
4 9 -0.04 123 14.87 232 424 2.38 / 11.51 3 59
5 15 -0.04 97 14.88 161 232 2.61 / 11.75 20 246
Average= 2.35
(KJ/cycle)

Cycle 3 GMT 24/ 7/2024 5:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 103 14.82 385 588 0.59 / 7.29 3 3
2 8 248.60 150 14.89 542 1211 1.80 / 8.50 3 4
3 9 0.20 118 14.88 223 392 2.19 / 8.89 3 59
4 15 -0.12 102 14.87 159 241 2.43 / 9.13 17 246
Average= 2.28
(KJ/cycle)

Cycle 2 GMT 24/ 7/2024 3:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 103 14.89 389 597 0.60 / 4.91 3 3
2 8 235.24 150 14.91 525 1174 1.77 / 6.09 3 4
3 9 0.04 114 14.90 219 372 2.14 / 6.46 3 73
4 15 -0.16 106 14.91 156 247 2.39 / 6.70 23 247
Average= 2.23
(KJ/cycle)

Cycle 1 GMT 24/ 7/2024 2:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 103 15.05 388 601 0.60 / 2.60 3 3
2 8 208.04 151 15.01 485 1099 1.70 / 3.70 3 5
3 9 -0.04 103 14.97 220 339 2.04 / 4.04 3 53
4 15 -0.08 117 14.97 156 273 2.31 / 4.31 17 247
Average= 2.16
(KJ/cycle)

Cycle 0 GMT 24/ 7/2024 1:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 58.76 103 15.24 352 553 0.55 / 0.55 3 3
2 8 95.08 150 15.18 360 820 1.37 / 1.37 3 6
3 9 0.16 97 15.14 233 342 1.71 / 1.71 3 60
4 15 0.08 123 15.15 154 287 2.00 / 2.00 23 246
Average= 2.00
(KJ/cycle)