SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.44 | 28 | 14.96 | 528 | 221 | 0.22 / 584.25 | 2 | 2 |
2 | 3 | 1040.44 | 1 | 15.01 | 1994 | 30 | 0.25 / 584.28 | 2 | 3 |
3 | 7 | 2005.36 | 29 | 14.78 | 3179 | 1363 | 1.61 / 585.65 | 2 | 3 |
4 | 13 | 1601.64 | 17 | 14.75 | 2671 | 670 | 2.28 / 586.32 | 2 | 4 |
5 | 13 | 1062.52 | 17 | 14.78 | 1949 | 490 | 2.77 / 586.81 | 2 | 3 |
6 | 13 | 639.04 | 17 | 14.85 | 1360 | 343 | 3.12 / 587.15 | 2 | 4 |
7 | 13 | 210.08 | 17 | 14.97 | 702 | 179 | 3.30 / 587.33 | 2 | 3 |
8 | 13 | 20.40 | 17 | 15.02 | 403 | 103 | 3.40 / 587.43 | 2 | 3 |
9 | 8 | 0.20 | 165 | 14.99 | 351 | 868 | 4.27 / 588.30 | 2 | 6 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 29 | 14.96 | 520 | 226 | 0.23 / 579.88 | 2 | 3 |
2 | 3 | 963.88 | -1 | 15.35 | 0 | 0 | 0.00 / 579.88 | 2 | 3 |
3 | 7 | 2003.48 | 29 | 14.78 | 3178 | 1362 | 1.59 / 581.24 | 2 | 4 |
4 | 13 | 1728.72 | 17 | 14.74 | 2817 | 706 | 2.29 / 581.94 | 2 | 5 |
5 | 13 | 1141.24 | 17 | 14.78 | 2052 | 516 | 2.81 / 582.46 | 2 | 6 |
6 | 13 | 687.60 | 17 | 14.85 | 1431 | 361 | 3.17 / 582.82 | 2 | 5 |
7 | 13 | 248.36 | 17 | 14.96 | 777 | 198 | 3.37 / 583.02 | 2 | 3 |
8 | 13 | 22.92 | 17 | 15.02 | 421 | 107 | 3.48 / 583.13 | 2 | 4 |
9 | 8 | 0.08 | 165 | 14.99 | 366 | 905 | 4.38 / 584.03 | 2 | 6 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.08 | 28 | 14.97 | 521 | 218 | 0.22 / 575.72 | 2 | 3 |
2 | 3 | 1045.08 | 2 | 15.01 | 2013 | 60 | 0.28 / 575.78 | 2 | 3 |
3 | 7 | 2009.00 | 29 | 14.77 | 3168 | 1357 | 1.64 / 577.14 | 2 | 4 |
4 | 13 | 1488.76 | 17 | 14.76 | 2517 | 632 | 2.27 / 577.77 | 2 | 5 |
5 | 13 | 1069.00 | 17 | 14.78 | 1944 | 488 | 2.76 / 578.26 | 2 | 4 |
6 | 13 | 525.40 | 17 | 14.89 | 1186 | 300 | 3.06 / 578.56 | 2 | 4 |
7 | 13 | 135.88 | 17 | 14.99 | 617 | 157 | 3.21 / 578.72 | 2 | 3 |
8 | 8 | 0.12 | 165 | 14.99 | 378 | 935 | 4.15 / 579.65 | 2 | 10 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.08 | 28 | 14.97 | 496 | 208 | 0.21 / 571.43 | 2 | 3 |
2 | 7 | 2010.76 | 30 | 14.76 | 3179 | 1408 | 1.62 / 572.84 | 2 | 3 |
3 | 13 | 1588.16 | 17 | 14.75 | 2652 | 665 | 2.28 / 573.50 | 2 | 5 |
4 | 13 | 1153.04 | 17 | 14.78 | 2070 | 520 | 2.80 / 574.02 | 2 | 4 |
5 | 13 | 587.52 | 17 | 14.88 | 1285 | 325 | 3.13 / 574.35 | 2 | 4 |
6 | 13 | 177.56 | 17 | 14.99 | 661 | 168 | 3.29 / 574.52 | 2 | 3 |
7 | 13 | 18.04 | 17 | 15.03 | 399 | 102 | 3.40 / 574.62 | 2 | 4 |
8 | 8 | 0.00 | 165 | 14.99 | 358 | 885 | 4.28 / 575.50 | 2 | 4 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 28 | 14.97 | 495 | 207 | 0.21 / 567.01 | 2 | 3 |
2 | 7 | 2002.84 | 29 | 14.77 | 3157 | 1352 | 1.56 / 568.36 | 2 | 5 |
3 | 13 | 1610.92 | 17 | 14.75 | 2666 | 668 | 2.23 / 569.03 | 2 | 6 |
4 | 13 | 1054.12 | 17 | 14.79 | 1914 | 481 | 2.71 / 569.51 | 2 | 4 |
5 | 13 | 632.60 | 17 | 14.86 | 1349 | 341 | 3.05 / 569.85 | 2 | 5 |
6 | 13 | 201.32 | 17 | 14.98 | 719 | 183 | 3.23 / 570.04 | 2 | 3 |
7 | 13 | 47.48 | 17 | 15.02 | 456 | 116 | 3.35 / 570.15 | 2 | 3 |
8 | 8 | 0.12 | 165 | 14.99 | 366 | 905 | 4.26 / 571.06 | 2 | 7 |
9 | 14 | 0.12 | 30 | 14.96 | 363 | 163 | 4.42 / 571.22 | 3 | 9 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 28 | 14.97 | 485 | 203 | 0.20 / 562.82 | 2 | 3 |
2 | 7 | 2007.00 | 29 | 14.77 | 3156 | 1352 | 1.56 / 564.17 | 2 | 3 |
3 | 13 | 1597.96 | 17 | 14.76 | 2646 | 664 | 2.22 / 564.84 | 2 | 4 |
4 | 13 | 1038.72 | 17 | 14.80 | 1897 | 477 | 2.70 / 565.32 | 2 | 4 |
5 | 13 | 623.60 | 17 | 14.86 | 1337 | 338 | 3.03 / 565.65 | 2 | 4 |
6 | 13 | 192.20 | 17 | 14.98 | 668 | 170 | 3.20 / 565.82 | 2 | 4 |
7 | 13 | 38.12 | 17 | 15.02 | 427 | 109 | 3.31 / 565.93 | 2 | 4 |
8 | 8 | 0.04 | 165 | 14.99 | 352 | 871 | 4.18 / 566.80 | 2 | 6 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.32 | 29 | 14.97 | 499 | 217 | 0.22 / 558.58 | 2 | 3 |
2 | 3 | 977.68 | -1 | 15.37 | 0 | 0 | 0.00 / 558.58 | 2 | 3 |
3 | 7 | 2004.12 | 29 | 14.78 | 3172 | 1360 | 1.58 / 559.94 | 2 | 3 |
4 | 13 | 1737.24 | 17 | 14.74 | 2837 | 711 | 2.29 / 560.65 | 2 | 3 |
5 | 13 | 1038.40 | 17 | 14.80 | 1913 | 481 | 2.77 / 561.13 | 2 | 4 |
6 | 13 | 635.56 | 17 | 14.87 | 1345 | 340 | 3.11 / 561.47 | 2 | 4 |
7 | 13 | 206.48 | 17 | 14.98 | 696 | 177 | 3.29 / 561.65 | 2 | 4 |
8 | 13 | 41.56 | 17 | 15.02 | 432 | 110 | 3.40 / 561.76 | 2 | 3 |
9 | 8 | -0.04 | 165 | 15.00 | 349 | 864 | 4.26 / 562.62 | 2 | 5 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 29 | 14.97 | 506 | 220 | 0.22 / 554.31 | 2 | 3 |
2 | 7 | 2006.40 | 29 | 14.77 | 3183 | 1363 | 1.58 / 555.67 | 2 | 4 |
3 | 13 | 1584.60 | 17 | 14.76 | 2650 | 665 | 2.25 / 556.34 | 2 | 6 |
4 | 13 | 1152.20 | 17 | 14.78 | 2080 | 523 | 2.77 / 556.86 | 2 | 4 |
5 | 13 | 572.84 | 17 | 14.88 | 1281 | 324 | 3.09 / 557.18 | 2 | 4 |
6 | 13 | 167.64 | 17 | 14.99 | 650 | 166 | 3.26 / 557.35 | 2 | 4 |
7 | 13 | 41.48 | 17 | 15.02 | 445 | 114 | 3.37 / 557.46 | 2 | 3 |
8 | 8 | 0.08 | 165 | 14.99 | 363 | 898 | 4.27 / 558.36 | 2 | 4 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.12 | 29 | 14.97 | 533 | 231 | 0.23 / 550.03 | 2 | 3 |
2 | 3 | 1015.08 | 1 | 15.08 | 1982 | 30 | 0.26 / 550.06 | 2 | 3 |
3 | 7 | 2003.08 | 29 | 14.77 | 3170 | 1358 | 1.62 / 551.41 | 2 | 4 |
4 | 13 | 1586.00 | 17 | 14.76 | 2645 | 664 | 2.28 / 552.08 | 2 | 5 |
5 | 13 | 1149.12 | 17 | 14.77 | 2064 | 518 | 2.80 / 552.60 | 2 | 6 |
6 | 13 | 565.72 | 17 | 14.88 | 1252 | 317 | 3.12 / 552.91 | 2 | 4 |
7 | 13 | 155.88 | 17 | 15.00 | 629 | 160 | 3.28 / 553.07 | 2 | 3 |
8 | 13 | 42.84 | 17 | 15.03 | 446 | 114 | 3.39 / 553.19 | 2 | 3 |
9 | 8 | 0.08 | 165 | 15.00 | 364 | 901 | 4.29 / 554.09 | 2 | 6 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 29 | 14.98 | 488 | 212 | 0.21 / 545.59 | 2 | 3 |
2 | 7 | 2009.52 | 29 | 14.78 | 3178 | 1362 | 1.57 / 546.95 | 2 | 3 |
3 | 13 | 1733.08 | 17 | 14.74 | 2840 | 712 | 2.29 / 547.66 | 2 | 4 |
4 | 13 | 1150.48 | 17 | 14.78 | 2064 | 519 | 2.80 / 548.18 | 2 | 4 |
5 | 13 | 714.80 | 17 | 14.84 | 1476 | 372 | 3.18 / 548.55 | 2 | 4 |
6 | 13 | 272.56 | 17 | 14.96 | 826 | 210 | 3.39 / 548.76 | 2 | 3 |
7 | 13 | 60.48 | 17 | 15.02 | 488 | 125 | 3.51 / 548.89 | 2 | 3 |
8 | 8 | 0.08 | 165 | 14.99 | 368 | 910 | 4.42 / 549.80 | 2 | 7 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.04 | 30 | 14.98 | 485 | 218 | 0.22 / 541.34 | 2 | 3 |
2 | 3 | 978.84 | -1 | 15.35 | 0 | 0 | 0.00 / 541.34 | 2 | 3 |
3 | 3 | 1017.60 | 1 | 15.09 | 1954 | 29 | 0.25 / 541.37 | 2 | 3 |
4 | 7 | 2004.80 | 29 | 14.76 | 3178 | 1360 | 1.61 / 542.73 | 2 | 3 |
5 | 13 | 1597.68 | 17 | 14.75 | 2673 | 670 | 2.28 / 543.40 | 2 | 6 |
6 | 13 | 1045.00 | 17 | 14.79 | 1935 | 487 | 2.76 / 543.89 | 2 | 5 |
7 | 13 | 620.92 | 17 | 14.87 | 1330 | 336 | 3.10 / 544.22 | 2 | 5 |
8 | 13 | 195.24 | 17 | 14.99 | 681 | 174 | 3.27 / 544.40 | 2 | 3 |
9 | 13 | 48.36 | 17 | 15.03 | 440 | 112 | 3.39 / 544.51 | 2 | 3 |
10 | 8 | 0.16 | 165 | 15.00 | 349 | 864 | 4.25 / 545.37 | 2 | 6 |
Average= | 4.20 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.48 | 30 | 14.99 | 501 | 225 | 0.23 / 537.17 | 2 | 3 |
2 | 7 | 2004.08 | 29 | 14.77 | 3170 | 1358 | 1.58 / 538.53 | 2 | 5 |
3 | 13 | 1597.28 | 17 | 14.75 | 2662 | 667 | 2.25 / 539.20 | 2 | 3 |
4 | 13 | 1052.44 | 17 | 14.79 | 1915 | 481 | 2.73 / 539.68 | 2 | 4 |
5 | 13 | 631.56 | 17 | 14.87 | 1331 | 336 | 3.07 / 540.02 | 2 | 5 |
6 | 13 | 193.20 | 17 | 14.99 | 663 | 169 | 3.24 / 540.18 | 2 | 3 |
7 | 13 | 44.80 | 17 | 15.03 | 420 | 107 | 3.34 / 540.29 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.00 | 336 | 832 | 4.18 / 541.12 | 2 | 4 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.32 | 30 | 14.99 | 517 | 232 | 0.23 / 532.97 | 2 | 3 |
2 | 7 | 2008.52 | 29 | 14.77 | 3182 | 1363 | 1.60 / 534.34 | 2 | 3 |
3 | 13 | 1584.72 | 17 | 14.76 | 2642 | 663 | 2.26 / 535.00 | 2 | 4 |
4 | 13 | 1144.72 | 17 | 14.78 | 2055 | 516 | 2.77 / 535.52 | 2 | 5 |
5 | 13 | 584.76 | 17 | 14.89 | 1262 | 319 | 3.09 / 535.84 | 2 | 4 |
6 | 13 | 176.96 | 17 | 15.01 | 638 | 163 | 3.26 / 536.00 | 2 | 5 |
7 | 13 | 43.64 | 17 | 15.04 | 422 | 108 | 3.36 / 536.11 | 2 | 5 |
8 | 8 | 0.04 | 165 | 15.01 | 339 | 840 | 4.20 / 536.95 | 2 | 12 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 30 | 14.98 | 497 | 223 | 0.22 / 528.68 | 2 | 3 |
2 | 7 | 2003.96 | 30 | 14.78 | 3172 | 1406 | 1.63 / 530.09 | 2 | 3 |
3 | 13 | 1594.16 | 17 | 14.76 | 2662 | 668 | 2.30 / 530.76 | 2 | 5 |
4 | 13 | 1044.96 | 17 | 14.80 | 1909 | 480 | 2.78 / 531.24 | 2 | 3 |
5 | 13 | 629.04 | 17 | 14.87 | 1339 | 338 | 3.12 / 531.57 | 2 | 4 |
6 | 13 | 211.52 | 17 | 14.99 | 697 | 178 | 3.29 / 531.75 | 2 | 3 |
7 | 13 | 44.64 | 17 | 15.03 | 438 | 112 | 3.41 / 531.86 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.00 | 355 | 879 | 4.28 / 532.74 | 2 | 4 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.32 | 30 | 14.98 | 495 | 222 | 0.22 / 524.40 | 2 | 3 |
2 | 7 | 2008.20 | 29 | 14.77 | 3178 | 1361 | 1.58 / 525.76 | 2 | 3 |
3 | 13 | 1601.92 | 17 | 14.75 | 2678 | 672 | 2.26 / 526.43 | 2 | 5 |
4 | 13 | 1167.84 | 17 | 14.78 | 2089 | 525 | 2.78 / 526.96 | 2 | 4 |
5 | 13 | 600.08 | 17 | 14.88 | 1304 | 330 | 3.11 / 527.29 | 2 | 4 |
6 | 13 | 194.48 | 17 | 14.99 | 667 | 170 | 3.28 / 527.46 | 2 | 4 |
7 | 13 | 41.40 | 17 | 15.04 | 430 | 110 | 3.39 / 527.57 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.00 | 360 | 891 | 4.28 / 528.46 | 2 | 4 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 30 | 14.98 | 482 | 217 | 0.22 / 520.12 | 2 | 3 |
2 | 7 | 2003.72 | 29 | 14.78 | 3167 | 1357 | 1.57 / 521.48 | 2 | 3 |
3 | 13 | 1600.24 | 17 | 14.76 | 2647 | 664 | 2.24 / 522.14 | 2 | 5 |
4 | 13 | 1193.60 | 17 | 14.77 | 2120 | 532 | 2.77 / 522.67 | 2 | 5 |
5 | 13 | 624.20 | 17 | 14.87 | 1330 | 336 | 3.11 / 523.01 | 2 | 4 |
6 | 13 | 205.64 | 17 | 14.99 | 712 | 181 | 3.29 / 523.19 | 2 | 3 |
7 | 13 | 30.24 | 17 | 15.04 | 421 | 108 | 3.40 / 523.30 | 2 | 2 |
8 | 8 | 0.12 | 165 | 15.00 | 355 | 879 | 4.27 / 524.18 | 2 | 4 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 30 | 14.98 | 500 | 225 | 0.22 / 515.90 | 2 | 3 |
2 | 7 | 2003.72 | 29 | 14.77 | 3162 | 1354 | 1.58 / 517.26 | 2 | 3 |
3 | 13 | 1592.36 | 17 | 14.76 | 2650 | 665 | 2.24 / 517.92 | 2 | 5 |
4 | 13 | 1025.52 | 17 | 14.80 | 1895 | 477 | 2.72 / 518.40 | 2 | 4 |
5 | 13 | 623.04 | 17 | 14.87 | 1350 | 341 | 3.06 / 518.74 | 2 | 4 |
6 | 13 | 201.56 | 17 | 15.00 | 690 | 176 | 3.24 / 518.91 | 2 | 5 |
7 | 13 | 42.76 | 17 | 15.04 | 433 | 111 | 3.35 / 519.03 | 2 | 2 |
8 | 8 | -0.04 | 165 | 15.01 | 354 | 877 | 4.23 / 519.90 | 2 | 6 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.60 | 30 | 14.99 | 487 | 219 | 0.22 / 511.51 | 2 | 3 |
2 | 3 | 1018.08 | 1 | 15.07 | 1979 | 30 | 0.25 / 511.54 | 2 | 2 |
3 | 7 | 2006.16 | 29 | 14.77 | 3181 | 1363 | 1.61 / 512.90 | 2 | 3 |
4 | 13 | 1597.24 | 17 | 14.75 | 2669 | 669 | 2.28 / 513.57 | 2 | 4 |
5 | 13 | 1157.92 | 17 | 14.78 | 2083 | 523 | 2.80 / 514.09 | 2 | 6 |
6 | 13 | 714.20 | 17 | 14.85 | 1471 | 371 | 3.18 / 514.47 | 2 | 4 |
7 | 13 | 268.96 | 17 | 14.97 | 790 | 201 | 3.38 / 514.67 | 2 | 4 |
8 | 13 | 30.84 | 17 | 15.04 | 429 | 110 | 3.49 / 514.78 | 2 | 2 |
9 | 8 | 0.00 | 165 | 15.00 | 364 | 901 | 4.39 / 515.68 | 2 | 3 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 30 | 14.99 | 497 | 224 | 0.22 / 507.21 | 2 | 3 |
2 | 7 | 2010.04 | 29 | 14.79 | 3183 | 1365 | 1.59 / 508.57 | 2 | 3 |
3 | 13 | 1603.24 | 17 | 14.76 | 2681 | 673 | 2.26 / 509.25 | 2 | 4 |
4 | 13 | 1175.44 | 17 | 14.78 | 2095 | 526 | 2.79 / 509.77 | 2 | 4 |
5 | 13 | 615.88 | 17 | 14.89 | 1316 | 333 | 3.12 / 510.11 | 2 | 4 |
6 | 13 | 210.28 | 17 | 15.00 | 701 | 179 | 3.30 / 510.28 | 2 | 3 |
7 | 13 | 43.00 | 17 | 15.04 | 445 | 114 | 3.41 / 510.40 | 2 | 2 |
8 | 8 | 0.08 | 165 | 15.01 | 360 | 892 | 4.31 / 511.29 | 2 | 6 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.12 | 30 | 14.98 | 507 | 228 | 0.23 / 502.96 | 2 | 3 |
2 | 7 | 2002.76 | 29 | 14.78 | 3162 | 1355 | 1.58 / 504.32 | 2 | 3 |
3 | 13 | 1597.92 | 17 | 14.77 | 2671 | 671 | 2.25 / 504.99 | 2 | 5 |
4 | 13 | 1034.84 | 17 | 14.81 | 1903 | 479 | 2.73 / 505.47 | 2 | 4 |
5 | 13 | 617.16 | 17 | 14.89 | 1321 | 334 | 3.07 / 505.80 | 2 | 4 |
6 | 13 | 202.60 | 17 | 15.00 | 698 | 178 | 3.25 / 505.98 | 2 | 4 |
7 | 13 | 40.80 | 17 | 15.04 | 442 | 113 | 3.36 / 506.09 | 2 | 4 |
8 | 8 | 0.08 | 165 | 15.01 | 360 | 892 | 4.25 / 506.98 | 2 | 6 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.48 | 30 | 14.98 | 534 | 240 | 0.24 / 498.69 | 2 | 3 |
2 | 7 | 2010.40 | 29 | 14.77 | 3183 | 1363 | 1.60 / 500.05 | 2 | 4 |
3 | 13 | 1608.88 | 17 | 14.76 | 2664 | 668 | 2.27 / 500.72 | 2 | 4 |
4 | 13 | 1055.52 | 17 | 14.80 | 1929 | 485 | 2.76 / 501.21 | 2 | 4 |
5 | 13 | 633.12 | 17 | 14.88 | 1343 | 340 | 3.10 / 501.55 | 2 | 5 |
6 | 13 | 193.08 | 17 | 15.00 | 671 | 171 | 3.27 / 501.72 | 2 | 3 |
7 | 13 | 26.88 | 17 | 15.05 | 427 | 109 | 3.38 / 501.83 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.01 | 367 | 909 | 4.29 / 502.74 | 2 | 9 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.60 | 30 | 14.98 | 526 | 236 | 0.24 / 494.33 | 2 | 3 |
2 | 7 | 2007.48 | 30 | 14.78 | 3175 | 1408 | 1.64 / 495.74 | 2 | 3 |
3 | 13 | 1608.48 | 17 | 14.76 | 2676 | 671 | 2.32 / 496.41 | 2 | 6 |
4 | 13 | 1053.20 | 17 | 14.80 | 1930 | 486 | 2.80 / 496.89 | 2 | 4 |
5 | 13 | 632.64 | 17 | 14.88 | 1366 | 346 | 3.15 / 497.24 | 2 | 5 |
6 | 13 | 206.80 | 17 | 15.00 | 715 | 182 | 3.33 / 497.42 | 2 | 4 |
7 | 13 | 23.12 | 17 | 15.05 | 427 | 109 | 3.44 / 497.53 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.01 | 371 | 919 | 4.36 / 498.45 | 2 | 9 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.64 | 30 | 14.99 | 522 | 235 | 0.23 / 489.95 | 2 | 3 |
2 | 7 | 2005.08 | 29 | 14.79 | 3175 | 1362 | 1.60 / 491.32 | 2 | 3 |
3 | 13 | 1735.40 | 17 | 14.75 | 2856 | 716 | 2.31 / 492.03 | 2 | 4 |
4 | 13 | 1151.52 | 17 | 14.79 | 2076 | 522 | 2.83 / 492.55 | 2 | 5 |
5 | 13 | 597.40 | 17 | 14.90 | 1309 | 332 | 3.17 / 492.89 | 2 | 4 |
6 | 13 | 178.88 | 17 | 15.01 | 674 | 172 | 3.34 / 493.06 | 2 | 3 |
7 | 13 | 35.60 | 17 | 15.05 | 442 | 113 | 3.45 / 493.17 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.01 | 372 | 921 | 4.37 / 494.09 | 2 | 6 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.80 | 29 | 14.98 | 534 | 232 | 0.23 / 485.66 | 2 | 3 |
2 | 7 | 2003.20 | 29 | 14.78 | 3178 | 1362 | 1.59 / 487.02 | 2 | 3 |
3 | 13 | 1590.64 | 17 | 14.76 | 2659 | 667 | 2.26 / 487.69 | 2 | 4 |
4 | 13 | 1156.60 | 17 | 14.79 | 2077 | 522 | 2.78 / 488.21 | 2 | 5 |
5 | 13 | 581.28 | 17 | 14.89 | 1292 | 327 | 3.11 / 488.54 | 2 | 4 |
6 | 13 | 161.84 | 17 | 15.01 | 641 | 164 | 3.27 / 488.70 | 2 | 3 |
7 | 13 | 35.16 | 17 | 15.05 | 441 | 113 | 3.39 / 488.82 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.01 | 365 | 904 | 4.29 / 489.72 | 2 | 5 |
Average= | 4.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.44 | 29 | 14.99 | 524 | 228 | 0.23 / 481.30 | 2 | 3 |
2 | 3 | 1014.16 | 1 | 15.07 | 1964 | 30 | 0.26 / 481.32 | 2 | 3 |
3 | 7 | 2013.32 | 29 | 14.77 | 3188 | 1366 | 1.62 / 482.69 | 2 | 5 |
4 | 13 | 1615.48 | 17 | 14.76 | 2682 | 673 | 2.30 / 483.36 | 2 | 6 |
5 | 13 | 1066.20 | 17 | 14.81 | 1951 | 491 | 2.79 / 483.85 | 2 | 6 |
6 | 13 | 643.36 | 17 | 14.88 | 1372 | 347 | 3.13 / 484.20 | 2 | 4 |
7 | 13 | 214.04 | 17 | 15.00 | 722 | 184 | 3.32 / 484.39 | 2 | 3 |
8 | 13 | 23.12 | 17 | 15.05 | 434 | 111 | 3.43 / 484.50 | 2 | 3 |
9 | 8 | 0.08 | 165 | 15.01 | 376 | 931 | 4.36 / 485.43 | 2 | 7 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.04 | 30 | 14.99 | 529 | 238 | 0.24 / 476.94 | 2 | 3 |
2 | 10 | 1004.36 | 2 | 15.02 | 1909 | 57 | 0.30 / 477.00 | 2 | 3 |
3 | 3 | 947.52 | -1 | 15.36 | 0 | 0 | 0.06 / 477.00 | 2 | 3 |
4 | 3 | 972.96 | -1 | 15.38 | 0 | 0 | 0.06 / 477.00 | 2 | 3 |
5 | 7 | 2004.92 | 29 | 14.78 | 3161 | 1355 | 1.65 / 478.35 | 2 | 3 |
6 | 13 | 1611.40 | 17 | 14.76 | 2671 | 670 | 2.32 / 479.02 | 2 | 4 |
7 | 13 | 1158.28 | 17 | 14.79 | 2058 | 517 | 2.84 / 479.54 | 2 | 4 |
8 | 13 | 595.24 | 17 | 14.90 | 1293 | 328 | 3.17 / 479.87 | 2 | 4 |
9 | 13 | 174.60 | 17 | 15.02 | 660 | 169 | 3.33 / 480.04 | 2 | 3 |
10 | 13 | 18.76 | 17 | 15.05 | 419 | 107 | 3.44 / 480.14 | 2 | 3 |
11 | 8 | 0.08 | 165 | 15.01 | 373 | 924 | 4.36 / 481.07 | 2 | 7 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.56 | 30 | 14.98 | 543 | 244 | 0.24 / 472.59 | 2 | 2 |
2 | 7 | 2008.16 | 29 | 14.80 | 3182 | 1366 | 1.61 / 473.95 | 2 | 4 |
3 | 13 | 1741.96 | 17 | 14.76 | 2848 | 715 | 2.32 / 474.67 | 2 | 5 |
4 | 13 | 1145.36 | 17 | 14.80 | 2070 | 521 | 2.85 / 475.19 | 2 | 6 |
5 | 13 | 603.60 | 17 | 14.90 | 1319 | 334 | 3.18 / 475.52 | 2 | 4 |
6 | 13 | 196.24 | 17 | 15.01 | 689 | 176 | 3.36 / 475.70 | 2 | 4 |
7 | 13 | 18.12 | 17 | 15.06 | 405 | 104 | 3.46 / 475.80 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.02 | 364 | 902 | 4.36 / 476.70 | 2 | 7 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.20 | 30 | 14.99 | 539 | 242 | 0.24 / 468.25 | 2 | 3 |
2 | 7 | 2004.60 | 29 | 14.78 | 3172 | 1360 | 1.60 / 469.61 | 2 | 3 |
3 | 13 | 1597.08 | 17 | 14.77 | 2653 | 666 | 2.27 / 470.28 | 2 | 4 |
4 | 13 | 1038.08 | 17 | 14.82 | 1904 | 480 | 2.75 / 470.76 | 2 | 4 |
5 | 13 | 624.96 | 17 | 14.89 | 1348 | 341 | 3.09 / 471.10 | 2 | 4 |
6 | 13 | 194.80 | 17 | 15.00 | 709 | 181 | 3.27 / 471.28 | 2 | 3 |
7 | 13 | 16.72 | 17 | 15.05 | 427 | 109 | 3.38 / 471.39 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.01 | 384 | 951 | 4.33 / 472.34 | 2 | 6 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.00 | 29 | 14.99 | 523 | 227 | 0.23 / 463.98 | 2 | 3 |
2 | 3 | 1013.44 | 1 | 15.08 | 1984 | 30 | 0.26 / 464.01 | 2 | 3 |
3 | 7 | 2007.56 | 29 | 14.78 | 3173 | 1360 | 1.62 / 465.37 | 2 | 5 |
4 | 13 | 1611.44 | 17 | 14.76 | 2689 | 675 | 2.29 / 466.04 | 2 | 6 |
5 | 13 | 1187.20 | 17 | 14.79 | 2094 | 526 | 2.82 / 466.57 | 2 | 5 |
6 | 13 | 607.00 | 17 | 14.89 | 1325 | 335 | 3.15 / 466.90 | 2 | 4 |
7 | 13 | 179.80 | 17 | 15.01 | 671 | 171 | 3.33 / 467.08 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.02 | 378 | 937 | 4.26 / 468.01 | 2 | 8 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.04 | 29 | 15.00 | 531 | 231 | 0.23 / 459.51 | 2 | 2 |
2 | 7 | 2004.96 | 30 | 14.78 | 3173 | 1407 | 1.64 / 460.91 | 2 | 3 |
3 | 13 | 1742.56 | 17 | 14.75 | 2843 | 713 | 2.35 / 461.63 | 2 | 6 |
4 | 13 | 1136.20 | 17 | 14.80 | 2038 | 513 | 2.86 / 462.14 | 2 | 5 |
5 | 13 | 691.24 | 17 | 14.88 | 1417 | 358 | 3.22 / 462.50 | 2 | 4 |
6 | 13 | 243.16 | 17 | 15.00 | 759 | 194 | 3.42 / 462.69 | 2 | 5 |
7 | 8 | 0.08 | 165 | 15.03 | 361 | 895 | 4.31 / 463.59 | 2 | 6 |
8 | 14 | 0.08 | 30 | 15.00 | 362 | 163 | 4.47 / 463.75 | 2 | 11 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.52 | 30 | 14.99 | 533 | 240 | 0.24 / 455.26 | 2 | 2 |
2 | 3 | 979.40 | -1 | 15.39 | 0 | 0 | 0.00 / 455.26 | 2 | 2 |
3 | 7 | 2005.80 | 29 | 14.79 | 3183 | 1365 | 1.60 / 456.62 | 2 | 3 |
4 | 13 | 1601.16 | 17 | 14.77 | 2678 | 672 | 2.28 / 457.30 | 2 | 4 |
5 | 13 | 1176.48 | 17 | 14.79 | 2121 | 533 | 2.81 / 457.83 | 2 | 4 |
6 | 13 | 721.12 | 17 | 14.86 | 1485 | 375 | 3.19 / 458.20 | 2 | 4 |
7 | 13 | 154.44 | 17 | 15.03 | 626 | 160 | 3.35 / 458.36 | 2 | 4 |
8 | 8 | 0.16 | 165 | 15.03 | 368 | 913 | 4.26 / 459.28 | 2 | 4 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.76 | 29 | 15.00 | 534 | 232 | 0.23 / 451.01 | 2 | 3 |
2 | 7 | 2003.88 | 29 | 14.79 | 3164 | 1357 | 1.59 / 452.37 | 2 | 5 |
3 | 13 | 1586.20 | 17 | 14.77 | 2652 | 666 | 2.26 / 453.04 | 2 | 6 |
4 | 13 | 1129.28 | 17 | 14.80 | 2042 | 514 | 2.77 / 453.55 | 2 | 5 |
5 | 13 | 692.04 | 17 | 14.87 | 1444 | 365 | 3.13 / 453.92 | 2 | 4 |
6 | 13 | 146.16 | 17 | 15.03 | 627 | 160 | 3.29 / 454.08 | 2 | 4 |
7 | 8 | 0.08 | 165 | 15.03 | 380 | 942 | 4.24 / 455.02 | 2 | 6 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.20 | 29 | 15.00 | 517 | 225 | 0.22 / 446.74 | 2 | 3 |
2 | 3 | 1026.44 | 1 | 15.07 | 2008 | 30 | 0.26 / 446.77 | 2 | 3 |
3 | 7 | 2007.60 | 29 | 14.80 | 3189 | 1369 | 1.62 / 448.14 | 2 | 3 |
4 | 13 | 1606.36 | 17 | 14.77 | 2674 | 671 | 2.30 / 448.81 | 2 | 6 |
5 | 13 | 1175.68 | 17 | 14.79 | 2108 | 530 | 2.83 / 449.34 | 2 | 4 |
6 | 13 | 612.52 | 17 | 14.90 | 1319 | 334 | 3.16 / 449.67 | 2 | 4 |
7 | 13 | 203.12 | 17 | 15.01 | 711 | 181 | 3.34 / 449.85 | 2 | 5 |
8 | 8 | -0.12 | 165 | 15.03 | 374 | 928 | 4.27 / 450.78 | 2 | 12 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.20 | 29 | 14.99 | 533 | 232 | 0.23 / 442.55 | 2 | 2 |
2 | 7 | 2008.96 | 29 | 14.79 | 3175 | 1362 | 1.59 / 443.91 | 2 | 3 |
3 | 13 | 1613.08 | 17 | 14.78 | 2685 | 675 | 2.27 / 444.58 | 2 | 5 |
4 | 13 | 1176.92 | 17 | 14.80 | 2115 | 532 | 2.80 / 445.11 | 2 | 4 |
5 | 13 | 719.64 | 17 | 14.87 | 1473 | 372 | 3.17 / 445.49 | 2 | 5 |
6 | 13 | 163.08 | 17 | 15.03 | 617 | 158 | 3.33 / 445.64 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.04 | 350 | 869 | 4.20 / 446.51 | 2 | 12 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.08 | 28 | 15.00 | 537 | 226 | 0.23 / 438.32 | 2 | 2 |
2 | 3 | 1025.28 | 1 | 15.06 | 1984 | 30 | 0.26 / 438.35 | 2 | 3 |
3 | 7 | 2004.76 | 29 | 14.79 | 3176 | 1362 | 1.62 / 439.71 | 2 | 4 |
4 | 13 | 1596.84 | 17 | 14.78 | 2660 | 668 | 2.29 / 440.38 | 2 | 7 |
5 | 13 | 1050.72 | 17 | 14.82 | 1944 | 490 | 2.78 / 440.87 | 2 | 5 |
6 | 13 | 630.48 | 17 | 14.89 | 1362 | 345 | 3.12 / 441.22 | 2 | 5 |
7 | 13 | 191.68 | 17 | 15.01 | 693 | 177 | 3.30 / 441.39 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.02 | 371 | 919 | 4.22 / 442.31 | 2 | 9 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.52 | 28 | 14.99 | 527 | 221 | 0.22 / 434.15 | 2 | 2 |
2 | 7 | 2007.12 | 29 | 14.79 | 3174 | 1361 | 1.58 / 435.51 | 2 | 3 |
3 | 13 | 1598.28 | 17 | 14.77 | 2673 | 671 | 2.25 / 436.19 | 2 | 4 |
4 | 13 | 1040.28 | 17 | 14.83 | 1915 | 483 | 2.74 / 436.67 | 2 | 6 |
5 | 13 | 623.28 | 17 | 14.90 | 1346 | 341 | 3.08 / 437.01 | 2 | 4 |
6 | 13 | 195.28 | 17 | 15.02 | 678 | 173 | 3.25 / 437.18 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.03 | 369 | 915 | 4.17 / 438.10 | 2 | 5 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.16 | 28 | 14.99 | 532 | 223 | 0.22 / 430.01 | 2 | 3 |
2 | 7 | 2003.64 | 29 | 14.79 | 3156 | 1354 | 1.58 / 431.36 | 2 | 3 |
3 | 13 | 1597.32 | 17 | 14.78 | 2648 | 665 | 2.24 / 432.02 | 2 | 5 |
4 | 13 | 1032.80 | 17 | 14.83 | 1902 | 480 | 2.72 / 432.50 | 2 | 4 |
5 | 13 | 620.24 | 17 | 14.90 | 1327 | 336 | 3.06 / 432.84 | 2 | 5 |
6 | 13 | 199.00 | 17 | 15.02 | 680 | 174 | 3.23 / 433.01 | 2 | 4 |
7 | 8 | 0.04 | 165 | 15.03 | 370 | 918 | 4.15 / 433.93 | 2 | 6 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.60 | 29 | 15.00 | 518 | 225 | 0.23 / 425.69 | 2 | 2 |
2 | 3 | 975.80 | -1 | 15.37 | 0 | 0 | 0.00 / 425.69 | 2 | 2 |
3 | 7 | 2008.36 | 29 | 14.80 | 3170 | 1361 | 1.59 / 427.05 | 2 | 3 |
4 | 13 | 1604.44 | 17 | 14.78 | 2656 | 667 | 2.25 / 427.71 | 2 | 5 |
5 | 13 | 1042.76 | 17 | 14.83 | 1914 | 483 | 2.74 / 428.20 | 2 | 4 |
6 | 13 | 624.52 | 17 | 14.90 | 1334 | 338 | 3.07 / 428.53 | 2 | 5 |
7 | 13 | 198.68 | 17 | 15.01 | 704 | 180 | 3.25 / 428.71 | 2 | 6 |
8 | 8 | 0.12 | 165 | 15.03 | 365 | 905 | 4.16 / 429.62 | 2 | 7 |
9 | 14 | 0.12 | 30 | 15.00 | 364 | 164 | 4.32 / 429.78 | 2 | 7 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 30 | 15.01 | 508 | 229 | 0.23 / 421.58 | 2 | 3 |
2 | 7 | 2002.08 | 29 | 14.80 | 3155 | 1354 | 1.58 / 422.93 | 2 | 3 |
3 | 13 | 1593.52 | 17 | 14.78 | 2646 | 665 | 2.25 / 423.60 | 2 | 5 |
4 | 13 | 1026.80 | 17 | 14.83 | 1893 | 477 | 2.72 / 424.07 | 2 | 5 |
5 | 13 | 608.52 | 17 | 14.91 | 1314 | 333 | 3.06 / 424.41 | 2 | 5 |
6 | 13 | 184.12 | 17 | 15.03 | 661 | 169 | 3.23 / 424.57 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.04 | 357 | 886 | 4.11 / 425.46 | 2 | 5 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.96 | 30 | 15.00 | 530 | 238 | 0.24 / 417.40 | 2 | 3 |
2 | 7 | 2004.48 | 29 | 14.79 | 3165 | 1358 | 1.60 / 418.76 | 2 | 4 |
3 | 13 | 1732.20 | 17 | 14.76 | 2826 | 709 | 2.31 / 419.47 | 2 | 5 |
4 | 13 | 1140.76 | 17 | 14.81 | 2052 | 517 | 2.82 / 419.98 | 2 | 5 |
5 | 13 | 577.08 | 17 | 14.92 | 1261 | 320 | 3.14 / 420.30 | 2 | 5 |
6 | 13 | 162.80 | 17 | 15.04 | 621 | 159 | 3.30 / 420.46 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.04 | 357 | 886 | 4.19 / 421.35 | 2 | 12 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.60 | 30 | 14.99 | 528 | 237 | 0.24 / 412.99 | 2 | 2 |
2 | 7 | 2004.28 | 29 | 14.79 | 3174 | 1361 | 1.60 / 414.36 | 2 | 3 |
3 | 13 | 1724.80 | 17 | 14.76 | 2828 | 710 | 2.31 / 415.07 | 2 | 5 |
4 | 13 | 1142.92 | 17 | 14.81 | 2053 | 517 | 2.83 / 415.58 | 2 | 7 |
5 | 13 | 699.24 | 17 | 14.88 | 1450 | 367 | 3.19 / 415.95 | 2 | 5 |
6 | 13 | 259.32 | 17 | 15.01 | 784 | 200 | 3.39 / 416.15 | 2 | 3 |
7 | 13 | 24.60 | 17 | 15.07 | 417 | 107 | 3.50 / 416.26 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.03 | 365 | 905 | 4.40 / 417.16 | 2 | 9 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.08 | 29 | 15.01 | 523 | 228 | 0.23 / 408.76 | 2 | 3 |
2 | 3 | 1020.44 | 1 | 15.08 | 1988 | 30 | 0.26 / 408.79 | 2 | 2 |
3 | 7 | 2011.48 | 29 | 14.79 | 3179 | 1364 | 1.62 / 410.16 | 2 | 4 |
4 | 13 | 1604.56 | 17 | 14.78 | 2670 | 671 | 2.29 / 410.83 | 2 | 5 |
5 | 13 | 1050.80 | 17 | 14.83 | 1919 | 484 | 2.78 / 411.31 | 2 | 4 |
6 | 13 | 634.40 | 17 | 14.90 | 1353 | 343 | 3.12 / 411.66 | 2 | 4 |
7 | 13 | 202.28 | 17 | 15.02 | 710 | 181 | 3.30 / 411.84 | 2 | 4 |
8 | 8 | 0.04 | 165 | 15.03 | 371 | 920 | 4.22 / 412.76 | 2 | 7 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.20 | 28 | 15.01 | 523 | 220 | 0.22 / 404.55 | 2 | 2 |
2 | 10 | 1016.80 | 3 | 15.02 | 1906 | 86 | 0.31 / 404.64 | 2 | 3 |
3 | 3 | 974.36 | -1 | 15.38 | 0 | 0 | 0.09 / 404.64 | 2 | 3 |
4 | 7 | 2003.60 | 29 | 14.79 | 3171 | 1360 | 1.67 / 406.00 | 2 | 3 |
5 | 13 | 1604.40 | 17 | 14.77 | 2665 | 669 | 2.33 / 406.66 | 2 | 4 |
6 | 13 | 1032.60 | 17 | 14.83 | 1901 | 479 | 2.81 / 407.14 | 2 | 6 |
7 | 13 | 620.32 | 17 | 14.91 | 1323 | 335 | 3.15 / 407.48 | 2 | 5 |
8 | 13 | 189.44 | 17 | 15.03 | 664 | 170 | 3.32 / 407.65 | 2 | 3 |
9 | 8 | 0.24 | 165 | 15.04 | 358 | 888 | 4.21 / 408.54 | 2 | 5 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 30 | 15.01 | 493 | 222 | 0.22 / 400.39 | 2 | 3 |
2 | 3 | 954.00 | -1 | 15.39 | 0 | 0 | 0.00 / 400.39 | 2 | 3 |
3 | 3 | 978.24 | -1 | 15.41 | 0 | 0 | 0.00 / 400.39 | 2 | 3 |
4 | 7 | 2009.40 | 29 | 14.79 | 3181 | 1364 | 1.59 / 401.75 | 2 | 4 |
5 | 13 | 1603.32 | 17 | 14.77 | 2675 | 672 | 2.26 / 402.42 | 2 | 3 |
6 | 13 | 1167.12 | 17 | 14.80 | 2083 | 524 | 2.78 / 402.95 | 2 | 4 |
7 | 13 | 599.28 | 17 | 14.91 | 1290 | 327 | 3.11 / 403.28 | 2 | 5 |
8 | 13 | 176.36 | 17 | 15.03 | 656 | 168 | 3.28 / 403.44 | 2 | 3 |
9 | 8 | 0.08 | 165 | 15.04 | 357 | 886 | 4.16 / 404.33 | 2 | 9 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.04 | 30 | 15.02 | 504 | 227 | 0.23 / 396.07 | 2 | 3 |
2 | 7 | 2004.08 | 29 | 14.79 | 3183 | 1365 | 1.59 / 397.44 | 2 | 3 |
3 | 13 | 1723.84 | 17 | 14.77 | 2835 | 712 | 2.30 / 398.15 | 2 | 4 |
4 | 13 | 1133.44 | 17 | 14.81 | 2040 | 514 | 2.82 / 398.66 | 2 | 5 |
5 | 13 | 699.16 | 17 | 14.89 | 1431 | 362 | 3.18 / 399.02 | 2 | 4 |
6 | 13 | 147.20 | 17 | 15.05 | 596 | 152 | 3.33 / 399.18 | 2 | 3 |
7 | 13 | 38.44 | 17 | 15.07 | 428 | 110 | 3.44 / 399.29 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.04 | 355 | 881 | 4.32 / 400.17 | 2 | 7 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.20 | 30 | 15.01 | 515 | 232 | 0.23 / 391.63 | 2 | 3 |
2 | 7 | 2003.08 | 29 | 14.79 | 3174 | 1361 | 1.59 / 392.99 | 2 | 5 |
3 | 13 | 1599.96 | 17 | 14.78 | 2676 | 672 | 2.27 / 393.66 | 2 | 6 |
4 | 13 | 1031.28 | 17 | 14.83 | 1914 | 483 | 2.75 / 394.15 | 2 | 6 |
5 | 13 | 614.24 | 17 | 14.91 | 1326 | 336 | 3.08 / 394.48 | 2 | 4 |
6 | 13 | 191.16 | 17 | 15.02 | 692 | 177 | 3.26 / 394.66 | 2 | 3 |
7 | 13 | 40.28 | 17 | 15.07 | 444 | 114 | 3.37 / 394.77 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.04 | 366 | 908 | 4.28 / 395.68 | 2 | 6 |
9 | 14 | 0.12 | 30 | 15.01 | 364 | 164 | 4.45 / 395.84 | 2 | 10 |
Average= | 4.17 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.12 | 30 | 15.02 | 521 | 235 | 0.23 / 387.38 | 2 | 3 |
2 | 7 | 2007.80 | 29 | 14.80 | 3178 | 1364 | 1.60 / 388.74 | 2 | 3 |
3 | 13 | 1597.12 | 17 | 14.78 | 2654 | 667 | 2.27 / 389.41 | 2 | 5 |
4 | 13 | 1157.36 | 17 | 14.81 | 2070 | 521 | 2.79 / 389.93 | 2 | 5 |
5 | 13 | 584.24 | 17 | 14.92 | 1272 | 323 | 3.11 / 390.25 | 2 | 3 |
6 | 13 | 170.36 | 17 | 15.04 | 630 | 161 | 3.27 / 390.41 | 2 | 3 |
7 | 13 | 34.60 | 17 | 15.07 | 420 | 108 | 3.38 / 390.52 | 2 | 3 |
8 | 8 | -0.04 | 165 | 15.04 | 353 | 876 | 4.25 / 391.40 | 2 | 4 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 30 | 15.01 | 507 | 228 | 0.23 / 383.10 | 2 | 3 |
2 | 7 | 2006.76 | 29 | 14.79 | 3159 | 1355 | 1.58 / 384.45 | 2 | 3 |
3 | 13 | 1604.00 | 17 | 14.78 | 2667 | 670 | 2.25 / 385.12 | 2 | 5 |
4 | 13 | 1178.24 | 17 | 14.80 | 2102 | 529 | 2.78 / 385.65 | 2 | 3 |
5 | 13 | 609.92 | 17 | 14.91 | 1324 | 336 | 3.12 / 385.99 | 2 | 4 |
6 | 13 | 185.60 | 17 | 15.04 | 656 | 168 | 3.29 / 386.15 | 2 | 3 |
7 | 13 | 40.56 | 17 | 15.07 | 427 | 109 | 3.39 / 386.26 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.04 | 354 | 878 | 4.27 / 387.14 | 2 | 9 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.20 | 29 | 15.01 | 523 | 228 | 0.23 / 378.74 | 2 | 3 |
2 | 3 | 1027.36 | 1 | 15.09 | 1955 | 30 | 0.26 / 378.77 | 2 | 2 |
3 | 7 | 2008.84 | 30 | 14.79 | 3188 | 1415 | 1.67 / 380.18 | 2 | 3 |
4 | 13 | 1599.92 | 17 | 14.78 | 2668 | 670 | 2.34 / 380.85 | 2 | 4 |
5 | 13 | 1165.08 | 17 | 14.81 | 2088 | 526 | 2.87 / 381.38 | 2 | 5 |
6 | 13 | 594.76 | 17 | 14.92 | 1296 | 329 | 3.20 / 381.71 | 2 | 4 |
7 | 13 | 184.00 | 17 | 15.04 | 656 | 168 | 3.36 / 381.87 | 2 | 3 |
8 | 13 | 35.72 | 17 | 15.08 | 421 | 108 | 3.47 / 381.98 | 2 | 4 |
9 | 8 | 0.04 | 165 | 15.04 | 358 | 888 | 4.36 / 382.87 | 2 | 6 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 30 | 15.01 | 502 | 226 | 0.23 / 374.47 | 2 | 3 |
2 | 3 | 977.48 | -1 | 15.42 | 0 | 0 | 0.00 / 374.47 | 2 | 3 |
3 | 7 | 2004.52 | 29 | 14.79 | 3162 | 1356 | 1.58 / 375.83 | 2 | 4 |
4 | 13 | 1603.00 | 17 | 14.78 | 2654 | 667 | 2.25 / 376.50 | 2 | 6 |
5 | 13 | 1037.20 | 17 | 14.84 | 1912 | 482 | 2.73 / 376.98 | 2 | 4 |
6 | 13 | 620.68 | 17 | 14.91 | 1352 | 343 | 3.07 / 377.32 | 2 | 5 |
7 | 13 | 194.48 | 17 | 15.03 | 685 | 175 | 3.25 / 377.50 | 2 | 3 |
8 | 13 | 37.64 | 17 | 15.07 | 439 | 112 | 3.36 / 377.61 | 2 | 3 |
9 | 8 | 0.12 | 165 | 15.04 | 362 | 898 | 4.26 / 378.51 | 2 | 8 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.44 | 29 | 15.01 | 520 | 226 | 0.23 / 370.14 | 2 | 3 |
2 | 3 | 1013.24 | 1 | 15.11 | 1966 | 30 | 0.26 / 370.16 | 2 | 3 |
3 | 7 | 2006.32 | 30 | 14.79 | 3170 | 1407 | 1.66 / 371.57 | 2 | 4 |
4 | 13 | 1580.12 | 17 | 14.79 | 2640 | 664 | 2.33 / 372.24 | 2 | 4 |
5 | 13 | 1033.12 | 17 | 14.85 | 1899 | 479 | 2.81 / 372.71 | 2 | 4 |
6 | 13 | 617.56 | 17 | 14.92 | 1326 | 336 | 3.14 / 373.05 | 2 | 5 |
7 | 13 | 191.36 | 17 | 15.04 | 677 | 173 | 3.32 / 373.22 | 2 | 4 |
8 | 13 | 37.76 | 17 | 15.07 | 445 | 114 | 3.43 / 373.34 | 2 | 4 |
9 | 8 | 0.08 | 165 | 15.04 | 367 | 911 | 4.34 / 374.25 | 2 | 9 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.04 | 29 | 15.01 | 492 | 214 | 0.21 / 365.85 | 2 | 3 |
2 | 7 | 2010.24 | 29 | 14.79 | 3174 | 1361 | 1.58 / 367.21 | 2 | 4 |
3 | 13 | 1613.60 | 17 | 14.78 | 2677 | 673 | 2.25 / 367.88 | 2 | 4 |
4 | 13 | 1057.12 | 17 | 14.84 | 1925 | 486 | 2.73 / 368.37 | 2 | 4 |
5 | 13 | 638.76 | 17 | 14.91 | 1352 | 343 | 3.08 / 368.71 | 2 | 4 |
6 | 13 | 209.04 | 17 | 15.03 | 694 | 177 | 3.25 / 368.89 | 2 | 3 |
7 | 13 | 37.08 | 17 | 15.07 | 439 | 112 | 3.37 / 369.00 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.04 | 367 | 911 | 4.28 / 369.91 | 2 | 9 |
Average= | 4.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 30 | 15.01 | 496 | 223 | 0.22 / 361.62 | 2 | 3 |
2 | 7 | 2007.56 | 29 | 14.79 | 3178 | 1363 | 1.59 / 362.98 | 2 | 3 |
3 | 13 | 1599.80 | 17 | 14.79 | 2667 | 671 | 2.26 / 363.65 | 2 | 5 |
4 | 13 | 1053.52 | 17 | 14.83 | 1946 | 491 | 2.75 / 364.14 | 2 | 4 |
5 | 13 | 632.24 | 17 | 14.91 | 1351 | 342 | 3.09 / 364.48 | 2 | 5 |
6 | 13 | 203.00 | 17 | 15.03 | 685 | 175 | 3.27 / 364.66 | 2 | 3 |
7 | 13 | 23.24 | 17 | 15.08 | 402 | 103 | 3.37 / 364.76 | 2 | 5 |
8 | 8 | 0.04 | 165 | 15.05 | 351 | 872 | 4.24 / 365.63 | 2 | 9 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.44 | 30 | 15.02 | 516 | 233 | 0.23 / 357.29 | 2 | 3 |
2 | 7 | 2005.96 | 30 | 14.79 | 3160 | 1402 | 1.63 / 358.69 | 2 | 4 |
3 | 13 | 1590.60 | 17 | 14.79 | 2651 | 667 | 2.30 / 359.35 | 2 | 5 |
4 | 13 | 1153.76 | 17 | 14.82 | 2069 | 521 | 2.82 / 359.87 | 2 | 5 |
5 | 13 | 588.12 | 17 | 14.93 | 1292 | 328 | 3.15 / 360.20 | 2 | 4 |
6 | 13 | 171.20 | 17 | 15.05 | 654 | 167 | 3.32 / 360.37 | 2 | 4 |
7 | 13 | 40.04 | 17 | 15.07 | 444 | 114 | 3.43 / 360.48 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.04 | 366 | 908 | 4.34 / 361.39 | 2 | 12 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.60 | 30 | 15.01 | 524 | 236 | 0.24 / 353.03 | 2 | 3 |
2 | 7 | 2005.32 | 29 | 14.79 | 3173 | 1361 | 1.60 / 354.39 | 2 | 3 |
3 | 13 | 1601.28 | 17 | 14.79 | 2671 | 672 | 2.27 / 355.06 | 2 | 4 |
4 | 13 | 1033.88 | 17 | 14.84 | 1911 | 482 | 2.75 / 355.54 | 2 | 6 |
5 | 13 | 621.60 | 17 | 14.92 | 1333 | 338 | 3.09 / 355.88 | 2 | 4 |
6 | 13 | 183.84 | 17 | 15.04 | 664 | 170 | 3.26 / 356.05 | 2 | 3 |
7 | 13 | 36.40 | 17 | 15.07 | 426 | 109 | 3.37 / 356.16 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.04 | 361 | 896 | 4.26 / 357.05 | 2 | 6 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.84 | 29 | 15.01 | 529 | 230 | 0.23 / 348.66 | 2 | 3 |
2 | 7 | 2008.72 | 29 | 14.81 | 3182 | 1367 | 1.60 / 350.03 | 2 | 4 |
3 | 13 | 1609.56 | 17 | 14.79 | 2680 | 674 | 2.27 / 350.71 | 2 | 4 |
4 | 13 | 1178.96 | 17 | 14.81 | 2107 | 530 | 2.80 / 351.24 | 2 | 6 |
5 | 13 | 734.52 | 17 | 14.89 | 1489 | 377 | 3.18 / 351.61 | 2 | 5 |
6 | 13 | 158.12 | 17 | 15.05 | 626 | 160 | 3.34 / 351.77 | 2 | 3 |
7 | 13 | 32.64 | 17 | 15.08 | 431 | 110 | 3.45 / 351.88 | 2 | 4 |
8 | 8 | 0.08 | 165 | 15.04 | 365 | 906 | 4.35 / 352.79 | 2 | 8 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.20 | 29 | 15.01 | 523 | 228 | 0.23 / 344.37 | 2 | 2 |
2 | 7 | 2006.88 | 29 | 14.81 | 3171 | 1362 | 1.59 / 345.73 | 2 | 3 |
3 | 13 | 1593.08 | 17 | 14.80 | 2656 | 668 | 2.26 / 346.40 | 2 | 4 |
4 | 13 | 1155.68 | 17 | 14.82 | 2073 | 522 | 2.78 / 346.92 | 2 | 4 |
5 | 13 | 604.88 | 17 | 14.93 | 1306 | 331 | 3.11 / 347.25 | 2 | 4 |
6 | 13 | 172.04 | 17 | 15.04 | 660 | 169 | 3.28 / 347.42 | 2 | 3 |
7 | 13 | 18.88 | 17 | 15.08 | 411 | 105 | 3.39 / 347.52 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.05 | 367 | 911 | 4.30 / 348.43 | 2 | 11 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.72 | 29 | 15.01 | 538 | 234 | 0.23 / 340.11 | 2 | 3 |
2 | 7 | 2004.36 | 29 | 14.82 | 3173 | 1364 | 1.60 / 341.47 | 2 | 3 |
3 | 13 | 1592.52 | 17 | 14.79 | 2655 | 668 | 2.27 / 342.14 | 2 | 5 |
4 | 13 | 1046.04 | 17 | 14.85 | 1924 | 486 | 2.75 / 342.62 | 2 | 5 |
5 | 13 | 633.92 | 17 | 14.92 | 1349 | 342 | 3.09 / 342.96 | 2 | 5 |
6 | 13 | 194.96 | 17 | 15.03 | 682 | 174 | 3.27 / 343.14 | 2 | 5 |
7 | 13 | 19.52 | 17 | 15.08 | 400 | 103 | 3.37 / 343.24 | 2 | 2 |
8 | 8 | 0.04 | 165 | 15.04 | 361 | 896 | 4.27 / 344.14 | 2 | 5 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.36 | 29 | 15.00 | 533 | 232 | 0.23 / 335.75 | 2 | 3 |
2 | 7 | 2008.64 | 29 | 14.80 | 3191 | 1370 | 1.60 / 337.12 | 2 | 5 |
3 | 13 | 1613.12 | 17 | 14.79 | 2693 | 677 | 2.28 / 337.80 | 2 | 6 |
4 | 13 | 1171.00 | 17 | 14.82 | 2086 | 526 | 2.80 / 338.32 | 2 | 6 |
5 | 13 | 591.24 | 17 | 14.93 | 1294 | 328 | 3.13 / 338.65 | 2 | 4 |
6 | 13 | 166.84 | 17 | 15.04 | 658 | 168 | 3.30 / 338.82 | 2 | 4 |
7 | 13 | 19.04 | 17 | 15.08 | 422 | 108 | 3.41 / 338.93 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.03 | 381 | 945 | 4.35 / 339.87 | 2 | 5 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.04 | 29 | 15.00 | 525 | 228 | 0.23 / 331.44 | 2 | 2 |
2 | 7 | 2006.36 | 29 | 14.81 | 3175 | 1364 | 1.59 / 332.80 | 2 | 3 |
3 | 13 | 1605.64 | 17 | 14.79 | 2685 | 675 | 2.27 / 333.48 | 2 | 4 |
4 | 13 | 1035.20 | 17 | 14.85 | 1908 | 482 | 2.75 / 333.96 | 2 | 5 |
5 | 13 | 615.56 | 17 | 14.92 | 1324 | 336 | 3.08 / 334.30 | 2 | 5 |
6 | 13 | 183.32 | 17 | 15.03 | 683 | 175 | 3.26 / 334.47 | 2 | 3 |
7 | 13 | 18.84 | 17 | 15.08 | 419 | 107 | 3.37 / 334.58 | 2 | 4 |
8 | 8 | 0.04 | 165 | 15.03 | 379 | 940 | 4.31 / 335.52 | 2 | 8 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 29 | 15.01 | 518 | 225 | 0.23 / 327.12 | 2 | 2 |
2 | 7 | 2004.36 | 30 | 14.81 | 3169 | 1408 | 1.63 / 328.53 | 2 | 3 |
3 | 13 | 1575.64 | 17 | 14.80 | 2626 | 661 | 2.29 / 329.19 | 2 | 6 |
4 | 13 | 1018.40 | 17 | 14.85 | 1903 | 480 | 2.77 / 329.67 | 2 | 4 |
5 | 13 | 608.96 | 17 | 14.92 | 1334 | 338 | 3.11 / 330.01 | 2 | 5 |
6 | 13 | 179.12 | 17 | 15.04 | 678 | 173 | 3.29 / 330.18 | 2 | 4 |
7 | 13 | 17.28 | 17 | 15.08 | 413 | 106 | 3.39 / 330.29 | 2 | 5 |
8 | 8 | 0.00 | 165 | 15.04 | 373 | 926 | 4.32 / 331.21 | 2 | 7 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 29 | 15.01 | 532 | 232 | 0.23 / 322.95 | 2 | 2 |
2 | 7 | 2003.44 | 29 | 14.81 | 3170 | 1361 | 1.59 / 324.32 | 2 | 3 |
3 | 13 | 1597.84 | 17 | 14.80 | 2663 | 670 | 2.26 / 324.99 | 2 | 6 |
4 | 13 | 1050.52 | 17 | 14.84 | 1924 | 485 | 2.75 / 325.47 | 2 | 5 |
5 | 13 | 629.88 | 17 | 14.92 | 1345 | 341 | 3.09 / 325.81 | 2 | 5 |
6 | 13 | 188.40 | 17 | 15.04 | 674 | 172 | 3.26 / 325.99 | 2 | 6 |
7 | 8 | 0.12 | 165 | 15.04 | 366 | 908 | 4.17 / 326.89 | 2 | 4 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.32 | 29 | 15.02 | 532 | 232 | 0.23 / 318.75 | 2 | 3 |
2 | 7 | 2002.36 | 29 | 14.81 | 3169 | 1361 | 1.59 / 320.12 | 2 | 3 |
3 | 13 | 1595.00 | 17 | 14.80 | 2669 | 672 | 2.26 / 320.79 | 2 | 4 |
4 | 13 | 1155.04 | 17 | 14.83 | 2065 | 521 | 2.78 / 321.31 | 2 | 4 |
5 | 13 | 566.28 | 17 | 14.93 | 1273 | 323 | 3.11 / 321.63 | 2 | 5 |
6 | 13 | 150.32 | 17 | 15.05 | 620 | 159 | 3.27 / 321.79 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.05 | 376 | 934 | 4.20 / 322.72 | 2 | 8 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.68 | 29 | 15.01 | 547 | 238 | 0.24 / 314.62 | 2 | 3 |
2 | 7 | 2004.84 | 29 | 14.82 | 3174 | 1364 | 1.60 / 315.98 | 2 | 3 |
3 | 13 | 1592.24 | 17 | 14.81 | 2659 | 669 | 2.27 / 316.65 | 2 | 6 |
4 | 13 | 1039.56 | 17 | 14.85 | 1937 | 489 | 2.76 / 317.14 | 2 | 5 |
5 | 13 | 620.48 | 17 | 14.92 | 1356 | 344 | 3.10 / 317.48 | 2 | 5 |
6 | 13 | 104.24 | 17 | 15.07 | 538 | 138 | 3.24 / 317.62 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.05 | 363 | 901 | 4.14 / 318.52 | 2 | 4 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.88 | 29 | 15.02 | 529 | 230 | 0.23 / 310.42 | 2 | 3 |
2 | 7 | 2007.96 | 29 | 14.82 | 3183 | 1368 | 1.60 / 311.78 | 2 | 3 |
3 | 13 | 1595.72 | 17 | 14.80 | 2676 | 673 | 2.27 / 312.46 | 2 | 4 |
4 | 13 | 1026.08 | 17 | 14.85 | 1905 | 481 | 2.75 / 312.94 | 2 | 6 |
5 | 13 | 611.00 | 17 | 14.92 | 1326 | 336 | 3.09 / 313.27 | 2 | 4 |
6 | 13 | 103.48 | 17 | 15.06 | 574 | 147 | 3.24 / 313.42 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.05 | 386 | 959 | 4.19 / 314.38 | 2 | 8 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.88 | 29 | 15.02 | 527 | 230 | 0.23 / 306.14 | 2 | 2 |
2 | 3 | 1022.64 | 1 | 15.10 | 1994 | 30 | 0.26 / 306.17 | 2 | 3 |
3 | 7 | 2001.88 | 29 | 14.82 | 3174 | 1364 | 1.62 / 307.54 | 2 | 3 |
4 | 13 | 1574.20 | 17 | 14.81 | 2656 | 669 | 2.29 / 308.21 | 2 | 3 |
5 | 13 | 1132.72 | 17 | 14.84 | 2049 | 517 | 2.81 / 308.72 | 2 | 4 |
6 | 13 | 675.32 | 17 | 14.91 | 1415 | 359 | 3.17 / 309.08 | 2 | 5 |
7 | 13 | 124.00 | 17 | 15.06 | 595 | 152 | 3.32 / 309.23 | 2 | 2 |
8 | 8 | 0.04 | 165 | 15.05 | 383 | 951 | 4.27 / 310.18 | 2 | 7 |
Average= | 4.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.48 | 29 | 15.02 | 543 | 237 | 0.24 / 302.07 | 2 | 2 |
2 | 7 | 2009.20 | 29 | 14.82 | 3189 | 1371 | 1.61 / 303.44 | 2 | 4 |
3 | 13 | 1480.08 | 17 | 14.83 | 2501 | 631 | 2.24 / 304.07 | 2 | 5 |
4 | 13 | 961.04 | 17 | 14.88 | 1799 | 455 | 2.69 / 304.53 | 2 | 6 |
5 | 13 | 556.52 | 17 | 14.95 | 1234 | 314 | 3.01 / 304.84 | 2 | 5 |
6 | 13 | 130.84 | 17 | 15.06 | 597 | 153 | 3.16 / 304.99 | 2 | 4 |
7 | 8 | 0.12 | 165 | 15.05 | 370 | 919 | 4.08 / 305.91 | 2 | 10 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.32 | 29 | 15.02 | 535 | 233 | 0.23 / 297.86 | 2 | 3 |
2 | 7 | 2005.32 | 29 | 14.83 | 3165 | 1361 | 1.59 / 299.22 | 2 | 5 |
3 | 13 | 1596.68 | 17 | 14.81 | 2671 | 672 | 2.27 / 299.90 | 2 | 3 |
4 | 13 | 1037.64 | 17 | 14.86 | 1919 | 485 | 2.75 / 300.38 | 2 | 4 |
5 | 13 | 609.08 | 17 | 14.93 | 1315 | 334 | 3.09 / 300.71 | 2 | 4 |
6 | 13 | 173.92 | 17 | 15.05 | 673 | 172 | 3.26 / 300.89 | 2 | 4 |
7 | 8 | 0.00 | 165 | 15.05 | 382 | 949 | 4.21 / 301.84 | 2 | 10 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.60 | 28 | 15.02 | 538 | 226 | 0.23 / 293.62 | 2 | 2 |
2 | 7 | 2003.12 | 30 | 14.83 | 3170 | 1410 | 1.64 / 295.03 | 2 | 3 |
3 | 13 | 1591.60 | 17 | 14.82 | 2670 | 673 | 2.31 / 295.70 | 2 | 5 |
4 | 13 | 1040.76 | 17 | 14.86 | 1927 | 487 | 2.80 / 296.19 | 2 | 4 |
5 | 13 | 615.08 | 17 | 14.93 | 1348 | 342 | 3.14 / 296.53 | 2 | 4 |
6 | 13 | 182.24 | 17 | 15.06 | 669 | 171 | 3.31 / 296.70 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.06 | 372 | 924 | 4.23 / 297.63 | 2 | 4 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.04 | 29 | 15.03 | 544 | 237 | 0.24 / 289.41 | 2 | 2 |
2 | 7 | 2004.12 | 29 | 14.84 | 3175 | 1366 | 1.60 / 290.77 | 2 | 4 |
3 | 13 | 1595.60 | 17 | 14.82 | 2664 | 671 | 2.27 / 291.44 | 2 | 6 |
4 | 13 | 1155.76 | 17 | 14.85 | 2082 | 526 | 2.80 / 291.97 | 2 | 4 |
5 | 13 | 568.00 | 17 | 14.95 | 1263 | 321 | 3.12 / 292.29 | 2 | 5 |
6 | 13 | 144.96 | 17 | 15.07 | 626 | 160 | 3.28 / 292.45 | 2 | 6 |
7 | 8 | 0.08 | 165 | 15.06 | 380 | 944 | 4.23 / 293.40 | 2 | 7 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.92 | 28 | 15.03 | 552 | 232 | 0.23 / 285.20 | 2 | 2 |
2 | 3 | 1020.56 | 1 | 15.12 | 1993 | 30 | 0.26 / 285.23 | 2 | 3 |
3 | 7 | 2006.84 | 29 | 14.84 | 3176 | 1367 | 1.63 / 286.60 | 2 | 3 |
4 | 13 | 1600.28 | 17 | 14.82 | 2662 | 671 | 2.30 / 287.27 | 2 | 5 |
5 | 13 | 1026.76 | 17 | 14.88 | 1892 | 479 | 2.78 / 287.75 | 2 | 6 |
6 | 13 | 595.60 | 17 | 14.95 | 1299 | 330 | 3.11 / 288.08 | 2 | 4 |
7 | 13 | 160.84 | 17 | 15.07 | 633 | 162 | 3.27 / 288.24 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.07 | 373 | 927 | 4.20 / 289.17 | 2 | 9 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.44 | 28 | 15.03 | 558 | 235 | 0.23 / 280.90 | 2 | 2 |
2 | 10 | 1008.44 | 3 | 15.05 | 1921 | 87 | 0.32 / 280.99 | 2 | 3 |
3 | 3 | 943.80 | -2 | 15.41 | 0 | 0 | 0.09 / 280.99 | 2 | 3 |
4 | 3 | 1020.68 | 1 | 15.13 | 1974 | 30 | 0.35 / 281.02 | 2 | 3 |
5 | 7 | 2006.08 | 29 | 14.83 | 3177 | 1366 | 1.72 / 282.38 | 2 | 4 |
6 | 13 | 1595.12 | 17 | 14.83 | 2665 | 672 | 2.39 / 283.06 | 2 | 5 |
7 | 13 | 1027.68 | 17 | 14.88 | 1901 | 481 | 2.87 / 283.54 | 2 | 5 |
8 | 13 | 605.68 | 17 | 14.95 | 1307 | 332 | 3.20 / 283.87 | 2 | 6 |
9 | 13 | 91.44 | 17 | 15.09 | 543 | 139 | 3.34 / 284.01 | 2 | 9 |
10 | 8 | 0.04 | 165 | 15.07 | 387 | 962 | 4.30 / 284.97 | 2 | 4 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 27 | 15.05 | 535 | 217 | 0.22 / 276.57 | 2 | 2 |
2 | 3 | 1042.08 | 2 | 15.10 | 2011 | 61 | 0.28 / 276.63 | 2 | 3 |
3 | 7 | 2005.28 | 29 | 14.83 | 3183 | 1369 | 1.65 / 278.00 | 2 | 3 |
4 | 13 | 1734.24 | 17 | 14.81 | 2834 | 714 | 2.36 / 278.71 | 2 | 4 |
5 | 13 | 1020.20 | 17 | 14.88 | 1879 | 475 | 2.84 / 279.19 | 2 | 5 |
6 | 13 | 600.88 | 17 | 14.95 | 1312 | 333 | 3.17 / 279.52 | 2 | 5 |
7 | 13 | 163.60 | 17 | 15.07 | 668 | 171 | 3.34 / 279.69 | 2 | 4 |
8 | 8 | 0.08 | 165 | 15.07 | 391 | 972 | 4.31 / 280.67 | 2 | 7 |
Average= | 4.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 29 | 15.04 | 523 | 228 | 0.23 / 272.29 | 2 | 2 |
2 | 3 | 934.08 | -2 | 15.42 | 0 | 0 | 0.00 / 272.29 | 2 | 2 |
3 | 7 | 2005.12 | 30 | 14.84 | 3177 | 1414 | 1.64 / 273.71 | 2 | 3 |
4 | 13 | 1603.64 | 17 | 14.83 | 2678 | 675 | 2.32 / 274.38 | 2 | 5 |
5 | 13 | 1149.76 | 17 | 14.86 | 2077 | 525 | 2.84 / 274.91 | 2 | 5 |
6 | 13 | 684.08 | 17 | 14.94 | 1436 | 365 | 3.21 / 275.27 | 2 | 5 |
7 | 13 | 133.32 | 17 | 15.09 | 585 | 150 | 3.36 / 275.42 | 2 | 5 |
8 | 8 | 0.04 | 165 | 15.08 | 374 | 931 | 4.29 / 276.35 | 2 | 6 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 29 | 15.06 | 518 | 226 | 0.23 / 268.09 | 2 | 3 |
2 | 7 | 2009.72 | 30 | 14.85 | 3173 | 1414 | 1.64 / 269.50 | 2 | 3 |
3 | 13 | 1465.96 | 17 | 14.85 | 2487 | 628 | 2.27 / 270.13 | 2 | 5 |
4 | 13 | 1189.64 | 17 | 14.85 | 2117 | 534 | 2.80 / 270.67 | 2 | 6 |
5 | 13 | 608.52 | 17 | 14.96 | 1309 | 333 | 3.13 / 271.00 | 2 | 5 |
6 | 13 | 97.48 | 17 | 15.10 | 537 | 138 | 3.27 / 271.14 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.09 | 373 | 929 | 4.20 / 272.07 | 2 | 8 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.40 | 29 | 15.06 | 521 | 228 | 0.23 / 263.96 | 2 | 3 |
2 | 7 | 2002.60 | 29 | 14.84 | 3178 | 1368 | 1.60 / 265.33 | 2 | 3 |
3 | 13 | 1584.36 | 17 | 14.84 | 2648 | 668 | 2.26 / 266.00 | 2 | 5 |
4 | 13 | 1024.48 | 17 | 14.89 | 1894 | 479 | 2.74 / 266.48 | 2 | 4 |
5 | 13 | 596.64 | 17 | 14.97 | 1293 | 329 | 3.07 / 266.81 | 2 | 5 |
6 | 13 | 159.12 | 17 | 15.09 | 622 | 160 | 3.23 / 266.97 | 2 | 4 |
7 | 8 | 0.20 | 165 | 15.09 | 361 | 899 | 4.13 / 267.86 | 2 | 8 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.48 | 29 | 15.07 | 526 | 230 | 0.23 / 259.67 | 2 | 2 |
2 | 7 | 2004.20 | 29 | 14.85 | 3174 | 1367 | 1.60 / 261.04 | 2 | 3 |
3 | 13 | 1593.44 | 17 | 14.84 | 2652 | 669 | 2.27 / 261.71 | 2 | 5 |
4 | 13 | 1038.80 | 17 | 14.89 | 1912 | 484 | 2.75 / 262.19 | 2 | 3 |
5 | 13 | 607.52 | 17 | 14.97 | 1306 | 332 | 3.08 / 262.52 | 2 | 5 |
6 | 13 | 170.12 | 17 | 15.09 | 643 | 165 | 3.25 / 262.69 | 2 | 4 |
7 | 8 | -0.04 | 165 | 15.10 | 355 | 884 | 4.13 / 263.57 | 2 | 9 |
8 | 14 | -0.04 | 30 | 15.07 | 356 | 161 | 4.29 / 263.73 | 2 | 7 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.44 | 28 | 15.07 | 533 | 225 | 0.22 / 255.44 | 2 | 3 |
2 | 3 | 1020.36 | 1 | 15.14 | 1981 | 30 | 0.25 / 255.47 | 2 | 3 |
3 | 7 | 2003.44 | 30 | 14.85 | 3171 | 1413 | 1.67 / 256.89 | 2 | 3 |
4 | 13 | 1594.32 | 17 | 14.85 | 2655 | 670 | 2.34 / 257.56 | 2 | 6 |
5 | 13 | 1035.04 | 17 | 14.90 | 1915 | 485 | 2.82 / 258.04 | 2 | 4 |
6 | 13 | 621.80 | 17 | 14.96 | 1358 | 345 | 3.17 / 258.39 | 2 | 5 |
7 | 13 | 180.72 | 17 | 15.09 | 660 | 169 | 3.34 / 258.56 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.10 | 356 | 887 | 4.22 / 259.44 | 2 | 8 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.24 | 28 | 15.08 | 515 | 217 | 0.22 / 251.28 | 2 | 3 |
2 | 7 | 2005.56 | 29 | 14.85 | 3185 | 1372 | 1.59 / 252.65 | 2 | 3 |
3 | 13 | 1594.64 | 17 | 14.84 | 2662 | 672 | 2.26 / 253.32 | 2 | 6 |
4 | 13 | 1041.00 | 17 | 14.90 | 1911 | 484 | 2.74 / 253.80 | 2 | 4 |
5 | 13 | 610.04 | 17 | 14.98 | 1317 | 335 | 3.08 / 254.14 | 2 | 7 |
6 | 13 | 177.28 | 17 | 15.10 | 648 | 166 | 3.25 / 254.31 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.11 | 366 | 912 | 4.16 / 255.22 | 2 | 12 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 29 | 15.08 | 505 | 221 | 0.22 / 247.05 | 2 | 3 |
2 | 3 | 972.52 | -1 | 15.44 | 0 | 0 | 0.00 / 247.05 | 2 | 3 |
3 | 3 | 1020.48 | 1 | 15.17 | 2000 | 30 | 0.25 / 247.08 | 2 | 3 |
4 | 7 | 2005.64 | 29 | 14.86 | 3177 | 1369 | 1.62 / 248.45 | 2 | 5 |
5 | 13 | 1605.04 | 17 | 14.85 | 2673 | 675 | 2.30 / 249.13 | 2 | 6 |
6 | 13 | 1040.20 | 17 | 14.91 | 1910 | 484 | 2.78 / 249.61 | 2 | 5 |
7 | 13 | 620.04 | 17 | 14.97 | 1337 | 340 | 3.12 / 249.95 | 2 | 5 |
8 | 13 | 188.96 | 17 | 15.10 | 693 | 178 | 3.30 / 250.13 | 2 | 3 |
9 | 8 | 0.20 | 165 | 15.11 | 373 | 930 | 4.23 / 251.06 | 2 | 8 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.44 | 29 | 15.08 | 531 | 232 | 0.23 / 242.84 | 2 | 3 |
2 | 7 | 2007.20 | 29 | 14.86 | 3175 | 1368 | 1.60 / 244.21 | 2 | 3 |
3 | 13 | 1588.12 | 17 | 14.84 | 2659 | 671 | 2.27 / 244.88 | 2 | 5 |
4 | 13 | 1138.88 | 17 | 14.89 | 2051 | 519 | 2.79 / 245.40 | 2 | 8 |
5 | 13 | 681.60 | 17 | 14.97 | 1421 | 362 | 3.15 / 245.76 | 2 | 4 |
6 | 13 | 129.24 | 17 | 15.12 | 591 | 152 | 3.30 / 245.91 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.12 | 368 | 918 | 4.22 / 246.83 | 2 | 12 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.36 | 28 | 15.09 | 535 | 226 | 0.23 / 238.46 | 2 | 3 |
2 | 3 | 1039.52 | 1 | 15.11 | 2032 | 31 | 0.26 / 238.50 | 2 | 3 |
3 | 7 | 2003.32 | 29 | 14.88 | 3173 | 1369 | 1.63 / 239.86 | 2 | 3 |
4 | 13 | 1591.92 | 17 | 14.86 | 2667 | 674 | 2.30 / 240.54 | 2 | 6 |
5 | 13 | 1161.64 | 17 | 14.89 | 2086 | 528 | 2.83 / 241.07 | 2 | 5 |
6 | 13 | 602.48 | 17 | 15.00 | 1305 | 333 | 3.16 / 241.40 | 2 | 4 |
7 | 13 | 171.12 | 17 | 15.11 | 667 | 171 | 3.33 / 241.57 | 2 | 3 |
8 | 13 | 33.80 | 17 | 15.15 | 443 | 114 | 3.45 / 241.68 | 2 | 3 |
9 | 8 | 0.04 | 165 | 15.11 | 371 | 925 | 4.37 / 242.61 | 2 | 7 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.56 | 29 | 15.10 | 509 | 223 | 0.22 / 234.30 | 2 | 2 |
2 | 3 | 965.40 | -1 | 15.45 | 0 | 0 | 0.00 / 234.30 | 2 | 2 |
3 | 7 | 2006.80 | 30 | 14.86 | 3182 | 1419 | 1.64 / 235.72 | 2 | 3 |
4 | 13 | 1476.12 | 17 | 14.88 | 2512 | 635 | 2.28 / 236.35 | 2 | 6 |
5 | 13 | 957.72 | 17 | 14.93 | 1811 | 460 | 2.74 / 236.81 | 2 | 7 |
6 | 13 | 552.08 | 17 | 15.01 | 1239 | 316 | 3.05 / 237.13 | 2 | 7 |
7 | 13 | 130.32 | 17 | 15.13 | 604 | 155 | 3.21 / 237.29 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.12 | 382 | 953 | 4.16 / 238.24 | 2 | 6 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.80 | 29 | 15.10 | 555 | 243 | 0.24 / 230.13 | 2 | 3 |
2 | 7 | 2002.48 | 29 | 14.87 | 3181 | 1372 | 1.61 / 231.50 | 2 | 5 |
3 | 13 | 1593.68 | 17 | 14.86 | 2660 | 672 | 2.29 / 232.17 | 2 | 6 |
4 | 13 | 1146.24 | 17 | 14.90 | 2081 | 527 | 2.81 / 232.70 | 2 | 8 |
5 | 13 | 582.76 | 17 | 15.01 | 1294 | 330 | 3.14 / 233.03 | 2 | 5 |
6 | 13 | 92.40 | 17 | 15.15 | 524 | 135 | 3.28 / 233.17 | 2 | 4 |
7 | 8 | 0.16 | 165 | 15.13 | 365 | 911 | 4.19 / 234.08 | 2 | 5 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.68 | 29 | 15.11 | 528 | 231 | 0.23 / 225.84 | 2 | 3 |
2 | 7 | 2004.16 | 29 | 14.87 | 3172 | 1368 | 1.60 / 227.21 | 2 | 5 |
3 | 13 | 1595.00 | 17 | 14.86 | 2667 | 674 | 2.27 / 227.88 | 2 | 5 |
4 | 13 | 1147.96 | 17 | 14.90 | 2062 | 522 | 2.80 / 228.40 | 2 | 5 |
5 | 13 | 687.52 | 17 | 14.98 | 1435 | 365 | 3.16 / 228.77 | 2 | 7 |
6 | 13 | 120.72 | 17 | 15.14 | 597 | 154 | 3.31 / 228.92 | 2 | 4 |
7 | 8 | 0.20 | 165 | 15.13 | 386 | 964 | 4.28 / 229.89 | 2 | 8 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.12 | 29 | 15.10 | 537 | 235 | 0.24 / 221.72 | 2 | 3 |
2 | 7 | 2006.04 | 29 | 14.88 | 3176 | 1371 | 1.61 / 223.09 | 2 | 4 |
3 | 13 | 1582.04 | 17 | 14.87 | 2643 | 668 | 2.27 / 223.76 | 2 | 4 |
4 | 13 | 1023.44 | 17 | 14.94 | 1886 | 479 | 2.75 / 224.24 | 2 | 6 |
5 | 13 | 601.56 | 17 | 15.01 | 1295 | 330 | 3.08 / 224.57 | 2 | 7 |
6 | 13 | 87.16 | 17 | 15.16 | 519 | 134 | 3.22 / 224.70 | 2 | 4 |
7 | 8 | 0.16 | 165 | 15.14 | 364 | 909 | 4.13 / 225.61 | 2 | 7 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.04 | 29 | 15.11 | 532 | 233 | 0.23 / 217.34 | 2 | 3 |
2 | 7 | 2005.48 | 29 | 14.89 | 3169 | 1368 | 1.60 / 218.71 | 2 | 5 |
3 | 13 | 1595.36 | 17 | 14.87 | 2658 | 672 | 2.27 / 219.38 | 2 | 6 |
4 | 13 | 1151.92 | 17 | 14.91 | 2084 | 528 | 2.80 / 219.91 | 2 | 6 |
5 | 13 | 692.60 | 17 | 14.99 | 1457 | 371 | 3.17 / 220.28 | 2 | 6 |
6 | 13 | 127.16 | 17 | 15.15 | 593 | 153 | 3.33 / 220.44 | 2 | 3 |
7 | 13 | 27.96 | 17 | 15.17 | 436 | 112 | 3.44 / 220.55 | 2 | 7 |
8 | 8 | 0.08 | 165 | 15.13 | 374 | 934 | 4.37 / 221.48 | 2 | 10 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.20 | 29 | 15.11 | 520 | 228 | 0.23 / 213.04 | 2 | 3 |
2 | 7 | 2002.72 | 29 | 14.89 | 3164 | 1366 | 1.59 / 214.41 | 2 | 3 |
3 | 13 | 1600.16 | 17 | 14.88 | 2660 | 673 | 2.27 / 215.08 | 2 | 6 |
4 | 13 | 1044.52 | 17 | 14.94 | 1916 | 487 | 2.75 / 215.57 | 2 | 5 |
5 | 13 | 629.48 | 17 | 15.02 | 1345 | 343 | 3.10 / 215.91 | 2 | 6 |
6 | 13 | 108.28 | 17 | 15.16 | 569 | 147 | 3.24 / 216.06 | 2 | 3 |
7 | 13 | 27.48 | 17 | 15.17 | 442 | 114 | 3.36 / 216.17 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.14 | 375 | 937 | 4.29 / 217.11 | 2 | 7 |
Average= | 4.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.48 | 29 | 15.12 | 514 | 225 | 0.23 / 208.77 | 2 | 3 |
2 | 7 | 2001.84 | 29 | 14.89 | 3161 | 1365 | 1.59 / 210.13 | 2 | 4 |
3 | 13 | 1594.44 | 17 | 14.88 | 2658 | 672 | 2.26 / 210.80 | 2 | 4 |
4 | 13 | 1027.24 | 17 | 14.95 | 1889 | 480 | 2.74 / 211.28 | 2 | 5 |
5 | 13 | 605.48 | 17 | 15.03 | 1306 | 334 | 3.08 / 211.62 | 2 | 6 |
6 | 13 | 166.56 | 17 | 15.14 | 655 | 169 | 3.25 / 211.79 | 2 | 4 |
7 | 13 | 36.92 | 17 | 15.17 | 442 | 114 | 3.36 / 211.90 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.14 | 367 | 917 | 4.28 / 212.82 | 2 | 6 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.72 | 29 | 15.11 | 549 | 241 | 0.24 / 204.44 | 2 | 3 |
2 | 3 | 1015.44 | 1 | 15.18 | 1989 | 30 | 0.27 / 204.47 | 2 | 4 |
3 | 7 | 2004.12 | 29 | 14.90 | 3172 | 1371 | 1.64 / 205.84 | 2 | 4 |
4 | 13 | 1583.04 | 17 | 14.89 | 2645 | 670 | 2.31 / 206.51 | 2 | 6 |
5 | 13 | 1135.20 | 17 | 14.93 | 2047 | 520 | 2.83 / 207.03 | 2 | 5 |
6 | 13 | 683.52 | 17 | 15.01 | 1420 | 362 | 3.19 / 207.39 | 2 | 6 |
7 | 13 | 132.88 | 17 | 15.17 | 579 | 149 | 3.34 / 207.54 | 2 | 4 |
8 | 13 | 27.20 | 17 | 15.19 | 419 | 108 | 3.45 / 207.65 | 2 | 3 |
9 | 8 | 0.04 | 165 | 15.15 | 356 | 890 | 4.34 / 208.54 | 2 | 8 |
Average= | 4.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.44 | 29 | 15.12 | 526 | 231 | 0.23 / 200.04 | 2 | 3 |
2 | 7 | 2005.08 | 30 | 14.89 | 3182 | 1421 | 1.65 / 201.46 | 2 | 4 |
3 | 13 | 1471.44 | 17 | 14.90 | 2503 | 634 | 2.29 / 202.10 | 2 | 6 |
4 | 13 | 1184.76 | 17 | 14.91 | 2121 | 538 | 2.82 / 202.63 | 2 | 4 |
5 | 13 | 592.00 | 17 | 15.03 | 1302 | 333 | 3.16 / 202.97 | 2 | 5 |
6 | 13 | 156.60 | 17 | 15.15 | 639 | 165 | 3.32 / 203.13 | 2 | 4 |
7 | 13 | 32.88 | 17 | 15.18 | 451 | 116 | 3.44 / 203.25 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.15 | 381 | 952 | 4.39 / 204.20 | 2 | 7 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.80 | 29 | 15.12 | 537 | 235 | 0.24 / 195.76 | 2 | 3 |
2 | 7 | 2007.72 | 29 | 14.89 | 3169 | 1368 | 1.60 / 197.13 | 2 | 3 |
3 | 13 | 1586.48 | 17 | 14.89 | 2657 | 673 | 2.28 / 197.80 | 2 | 5 |
4 | 13 | 1017.04 | 17 | 14.96 | 1886 | 480 | 2.76 / 198.28 | 2 | 5 |
5 | 13 | 594.60 | 17 | 15.04 | 1298 | 332 | 3.09 / 198.62 | 2 | 6 |
6 | 13 | 148.64 | 17 | 15.16 | 623 | 161 | 3.25 / 198.78 | 2 | 3 |
7 | 13 | 31.72 | 17 | 15.19 | 436 | 113 | 3.36 / 198.89 | 2 | 2 |
8 | 8 | 0.04 | 165 | 15.15 | 369 | 922 | 4.28 / 199.81 | 2 | 7 |
Average= | 4.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.52 | 29 | 15.13 | 533 | 234 | 0.23 / 191.40 | 2 | 3 |
2 | 7 | 2005.24 | 29 | 14.90 | 3195 | 1381 | 1.61 / 192.78 | 2 | 3 |
3 | 13 | 1599.92 | 17 | 14.89 | 2678 | 678 | 2.29 / 193.45 | 2 | 5 |
4 | 13 | 1034.96 | 17 | 14.96 | 1912 | 486 | 2.78 / 193.94 | 2 | 5 |
5 | 13 | 603.60 | 17 | 15.04 | 1313 | 336 | 3.11 / 194.28 | 2 | 4 |
6 | 13 | 159.04 | 17 | 15.16 | 664 | 171 | 3.29 / 194.45 | 2 | 3 |
7 | 13 | 30.92 | 17 | 15.18 | 457 | 118 | 3.40 / 194.57 | 2 | 4 |
8 | 8 | -0.08 | 165 | 15.15 | 385 | 962 | 4.37 / 195.53 | 2 | 6 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.44 | 28 | 15.14 | 522 | 221 | 0.22 / 187.03 | 2 | 3 |
2 | 3 | 1018.76 | 1 | 15.17 | 1991 | 30 | 0.25 / 187.06 | 2 | 3 |
3 | 7 | 2003.28 | 30 | 14.89 | 3183 | 1422 | 1.67 / 188.48 | 2 | 4 |
4 | 13 | 1598.48 | 17 | 14.89 | 2672 | 676 | 2.35 / 189.16 | 2 | 8 |
5 | 13 | 1033.36 | 17 | 14.96 | 1904 | 484 | 2.83 / 189.64 | 2 | 5 |
6 | 13 | 602.80 | 17 | 15.04 | 1311 | 335 | 3.17 / 189.98 | 2 | 5 |
7 | 13 | 92.00 | 17 | 15.18 | 546 | 141 | 3.31 / 190.12 | 2 | 3 |
8 | 13 | 25.24 | 17 | 15.19 | 432 | 112 | 3.42 / 190.23 | 2 | 4 |
9 | 8 | 0.04 | 165 | 15.16 | 373 | 933 | 4.35 / 191.16 | 2 | 10 |
Average= | 4.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.20 | 29 | 15.14 | 498 | 219 | 0.22 / 182.88 | 2 | 3 |
2 | 3 | 980.76 | -1 | 15.48 | 0 | 0 | 0.00 / 182.88 | 2 | 3 |
3 | 3 | 1019.56 | 1 | 15.20 | 1985 | 30 | 0.25 / 182.91 | 2 | 3 |
4 | 7 | 2002.60 | 29 | 14.91 | 3166 | 1369 | 1.62 / 184.28 | 2 | 5 |
5 | 13 | 1585.64 | 17 | 14.89 | 2641 | 669 | 2.29 / 184.95 | 2 | 4 |
6 | 13 | 1016.48 | 17 | 14.97 | 1900 | 484 | 2.77 / 185.43 | 2 | 8 |
7 | 13 | 596.24 | 17 | 15.05 | 1311 | 335 | 3.11 / 185.76 | 2 | 5 |
8 | 13 | 82.56 | 17 | 15.19 | 509 | 131 | 3.24 / 185.90 | 2 | 3 |
9 | 8 | 0.08 | 165 | 15.17 | 364 | 911 | 4.15 / 186.81 | 2 | 6 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.56 | 29 | 15.14 | 526 | 231 | 0.23 / 178.62 | 2 | 2 |
2 | 7 | 2008.16 | 29 | 14.90 | 3185 | 1376 | 1.61 / 180.00 | 2 | 5 |
3 | 13 | 1602.60 | 17 | 14.89 | 2671 | 676 | 2.28 / 180.67 | 2 | 5 |
4 | 13 | 1147.92 | 17 | 14.94 | 2066 | 525 | 2.81 / 181.20 | 2 | 5 |
5 | 13 | 570.64 | 17 | 15.06 | 1265 | 324 | 3.13 / 181.52 | 2 | 6 |
6 | 13 | 73.56 | 17 | 15.20 | 491 | 127 | 3.26 / 181.65 | 2 | 3 |
7 | 13 | 17.76 | 17 | 15.21 | 402 | 104 | 3.36 / 181.75 | 2 | 2 |
8 | 8 | 0.04 | 165 | 15.17 | 363 | 909 | 4.27 / 182.66 | 2 | 6 |
Average= | 4.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.32 | 29 | 15.15 | 532 | 234 | 0.23 / 174.35 | 2 | 3 |
2 | 7 | 2003.72 | 29 | 14.91 | 3177 | 1374 | 1.61 / 175.72 | 2 | 3 |
3 | 13 | 1599.00 | 17 | 14.90 | 2672 | 677 | 2.28 / 176.40 | 2 | 5 |
4 | 13 | 1047.76 | 17 | 14.97 | 1926 | 490 | 2.77 / 176.89 | 2 | 4 |
5 | 13 | 518.28 | 17 | 15.08 | 1191 | 305 | 3.08 / 177.20 | 2 | 4 |
6 | 13 | 122.32 | 17 | 15.19 | 582 | 150 | 3.23 / 177.35 | 2 | 3 |
7 | 13 | 20.44 | 17 | 15.20 | 423 | 109 | 3.34 / 177.46 | 2 | 7 |
8 | 8 | -0.04 | 165 | 15.17 | 372 | 931 | 4.27 / 178.39 | 2 | 5 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.56 | 29 | 15.15 | 532 | 234 | 0.23 / 170.13 | 2 | 3 |
2 | 7 | 2002.36 | 29 | 14.91 | 3167 | 1369 | 1.60 / 171.50 | 2 | 4 |
3 | 13 | 1584.48 | 17 | 14.90 | 2667 | 676 | 2.28 / 172.18 | 2 | 7 |
4 | 13 | 1138.12 | 17 | 14.96 | 2048 | 521 | 2.80 / 172.70 | 2 | 5 |
5 | 13 | 566.92 | 17 | 15.07 | 1261 | 323 | 3.12 / 173.02 | 2 | 5 |
6 | 13 | 146.92 | 17 | 15.19 | 625 | 161 | 3.28 / 173.18 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.18 | 373 | 934 | 4.22 / 174.12 | 2 | 5 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.16 | 28 | 15.15 | 538 | 228 | 0.23 / 165.93 | 2 | 2 |
2 | 7 | 2004.40 | 29 | 14.91 | 3173 | 1372 | 1.60 / 167.30 | 2 | 4 |
3 | 13 | 1594.52 | 17 | 14.91 | 2663 | 675 | 2.28 / 167.98 | 2 | 5 |
4 | 13 | 1040.36 | 17 | 14.98 | 1940 | 494 | 2.77 / 168.47 | 2 | 5 |
5 | 13 | 623.56 | 17 | 15.05 | 1338 | 342 | 3.11 / 168.82 | 2 | 5 |
6 | 13 | 102.60 | 17 | 15.20 | 556 | 144 | 3.26 / 168.96 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.19 | 375 | 940 | 4.20 / 169.90 | 2 | 5 |
Average= | 4.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.80 | 28 | 15.15 | 555 | 235 | 0.24 / 161.75 | 2 | 3 |
2 | 7 | 2005.56 | 29 | 14.91 | 3178 | 1374 | 1.61 / 163.13 | 2 | 4 |
3 | 13 | 1571.40 | 17 | 14.92 | 2621 | 665 | 2.27 / 163.79 | 2 | 6 |
4 | 13 | 1017.76 | 17 | 14.99 | 1907 | 486 | 2.76 / 164.28 | 2 | 7 |
5 | 13 | 589.76 | 17 | 15.07 | 1293 | 331 | 3.09 / 164.61 | 2 | 5 |
6 | 13 | 154.80 | 17 | 15.19 | 636 | 164 | 3.26 / 164.77 | 2 | 4 |
7 | 8 | 0.08 | 165 | 15.19 | 371 | 930 | 4.19 / 165.70 | 2 | 6 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.24 | 28 | 15.16 | 544 | 231 | 0.23 / 157.52 | 2 | 3 |
2 | 7 | 2003.80 | 29 | 14.91 | 3178 | 1374 | 1.61 / 158.89 | 2 | 3 |
3 | 13 | 1591.44 | 17 | 14.91 | 2666 | 676 | 2.28 / 159.57 | 2 | 6 |
4 | 13 | 1040.16 | 17 | 14.98 | 1915 | 488 | 2.77 / 160.06 | 2 | 6 |
5 | 13 | 604.84 | 17 | 15.07 | 1310 | 336 | 3.10 / 160.39 | 2 | 5 |
6 | 13 | 84.60 | 17 | 15.20 | 547 | 141 | 3.25 / 160.53 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.18 | 393 | 984 | 4.23 / 161.52 | 2 | 9 |
Average= | 4.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.20 | 28 | 15.17 | 526 | 223 | 0.22 / 153.32 | 2 | 3 |
2 | 7 | 2003.84 | 29 | 14.92 | 3170 | 1372 | 1.60 / 154.69 | 2 | 3 |
3 | 13 | 1575.64 | 17 | 14.92 | 2629 | 667 | 2.26 / 155.36 | 2 | 5 |
4 | 13 | 1139.00 | 17 | 14.97 | 2042 | 520 | 2.78 / 155.88 | 2 | 7 |
5 | 13 | 556.48 | 17 | 15.09 | 1227 | 315 | 3.10 / 156.19 | 2 | 5 |
6 | 13 | 73.12 | 17 | 15.22 | 513 | 133 | 3.23 / 156.33 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.19 | 384 | 962 | 4.19 / 157.29 | 2 | 9 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 28 | 15.16 | 533 | 226 | 0.23 / 149.15 | 2 | 3 |
2 | 7 | 2006.88 | 29 | 14.93 | 3177 | 1376 | 1.60 / 150.53 | 2 | 6 |
3 | 13 | 1594.28 | 17 | 14.92 | 2669 | 677 | 2.28 / 151.21 | 2 | 5 |
4 | 13 | 1044.24 | 17 | 14.99 | 1949 | 497 | 2.78 / 151.70 | 2 | 6 |
5 | 13 | 619.16 | 17 | 15.07 | 1333 | 342 | 3.12 / 152.04 | 2 | 7 |
6 | 13 | 97.00 | 17 | 15.21 | 526 | 136 | 3.25 / 152.18 | 2 | 5 |
7 | 8 | 0.00 | 165 | 15.20 | 366 | 918 | 4.17 / 153.10 | 2 | 8 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 28 | 15.16 | 558 | 237 | 0.24 / 144.96 | 2 | 3 |
2 | 7 | 2002.40 | 29 | 14.92 | 3188 | 1379 | 1.62 / 146.34 | 2 | 4 |
3 | 13 | 1572.84 | 17 | 14.92 | 2650 | 672 | 2.29 / 147.01 | 2 | 4 |
4 | 13 | 1003.24 | 17 | 15.00 | 1884 | 480 | 2.77 / 147.49 | 2 | 9 |
5 | 13 | 574.60 | 17 | 15.09 | 1269 | 326 | 3.09 / 147.82 | 2 | 6 |
6 | 13 | 134.92 | 17 | 15.20 | 608 | 157 | 3.25 / 147.98 | 2 | 6 |
7 | 8 | 0.08 | 165 | 15.20 | 379 | 951 | 4.20 / 148.93 | 2 | 8 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.20 | 27 | 15.17 | 532 | 218 | 0.22 / 140.65 | 2 | 2 |
2 | 10 | 1006.56 | 2 | 15.15 | 1916 | 58 | 0.28 / 140.71 | 2 | 4 |
3 | 3 | 947.28 | -1 | 15.49 | 0 | 0 | 0.06 / 140.71 | 2 | 4 |
4 | 7 | 2002.00 | 30 | 14.92 | 3167 | 1418 | 1.69 / 142.12 | 2 | 3 |
5 | 13 | 1574.96 | 17 | 14.93 | 2637 | 669 | 2.36 / 142.79 | 2 | 5 |
6 | 13 | 1012.96 | 17 | 15.01 | 1894 | 483 | 2.85 / 143.28 | 2 | 5 |
7 | 13 | 583.08 | 17 | 15.08 | 1283 | 329 | 3.18 / 143.60 | 2 | 6 |
8 | 13 | 79.12 | 17 | 15.22 | 539 | 139 | 3.31 / 143.74 | 2 | 3 |
9 | 8 | 0.04 | 165 | 15.20 | 391 | 981 | 4.30 / 144.72 | 2 | 5 |
Average= | 4.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 27 | 15.17 | 563 | 231 | 0.23 / 136.49 | 2 | 3 |
2 | 7 | 2003.64 | 29 | 14.93 | 3195 | 1383 | 1.61 / 137.88 | 2 | 5 |
3 | 13 | 1581.08 | 17 | 14.92 | 2658 | 674 | 2.29 / 138.55 | 2 | 4 |
4 | 13 | 1001.88 | 17 | 15.01 | 1882 | 480 | 2.77 / 139.03 | 2 | 6 |
5 | 13 | 585.12 | 17 | 15.08 | 1305 | 335 | 3.10 / 139.36 | 2 | 4 |
6 | 13 | 72.84 | 17 | 15.23 | 500 | 129 | 3.23 / 139.49 | 2 | 3 |
7 | 8 | -0.12 | 165 | 15.20 | 373 | 935 | 4.17 / 140.43 | 2 | 8 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.00 | 27 | 15.17 | 549 | 225 | 0.22 / 132.21 | 2 | 2 |
2 | 7 | 2005.92 | 30 | 14.93 | 3196 | 1431 | 1.66 / 133.64 | 2 | 5 |
3 | 13 | 1587.12 | 17 | 14.93 | 2665 | 676 | 2.33 / 134.32 | 2 | 5 |
4 | 13 | 1026.48 | 17 | 15.00 | 1923 | 490 | 2.82 / 134.81 | 2 | 7 |
5 | 13 | 589.92 | 17 | 15.08 | 1310 | 336 | 3.16 / 135.15 | 2 | 6 |
6 | 13 | 74.32 | 17 | 15.23 | 535 | 139 | 3.30 / 135.29 | 2 | 3 |
7 | 8 | 0.20 | 165 | 15.20 | 389 | 976 | 4.27 / 136.26 | 2 | 9 |
Average= | 4.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 27 | 15.17 | 546 | 224 | 0.22 / 128.01 | 2 | 3 |
2 | 7 | 2006.24 | 29 | 14.93 | 3183 | 1378 | 1.60 / 129.38 | 2 | 5 |
3 | 13 | 1575.88 | 17 | 14.94 | 2648 | 673 | 2.27 / 130.06 | 2 | 9 |
4 | 13 | 1012.24 | 17 | 15.01 | 1890 | 482 | 2.76 / 130.54 | 2 | 6 |
5 | 13 | 572.92 | 17 | 15.10 | 1285 | 330 | 3.09 / 130.87 | 2 | 6 |
6 | 13 | 129.52 | 17 | 15.22 | 604 | 156 | 3.24 / 131.02 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.21 | 384 | 964 | 4.21 / 131.99 | 2 | 8 |
Average= | 4.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.84 | 27 | 15.18 | 549 | 225 | 0.23 / 123.74 | 2 | 2 |
2 | 3 | 1013.76 | 1 | 15.23 | 1981 | 30 | 0.26 / 123.77 | 2 | 6 |
3 | 7 | 2007.88 | 29 | 14.94 | 3203 | 1388 | 1.64 / 125.16 | 2 | 7 |
4 | 13 | 1600.20 | 17 | 14.93 | 2677 | 679 | 2.32 / 125.84 | 2 | 6 |
5 | 13 | 1025.44 | 17 | 15.01 | 1906 | 486 | 2.81 / 126.32 | 2 | 14 |
6 | 13 | 601.88 | 17 | 15.09 | 1323 | 339 | 3.15 / 126.66 | 2 | 7 |
7 | 13 | 163.76 | 17 | 15.21 | 656 | 170 | 3.32 / 126.83 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.21 | 379 | 951 | 4.27 / 127.78 | 2 | 9 |
Average= | 3.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.48 | 27 | 15.18 | 554 | 227 | 0.23 / 119.58 | 2 | 2 |
2 | 3 | 1020.56 | 1 | 15.22 | 1998 | 30 | 0.26 / 119.61 | 2 | 5 |
3 | 7 | 2005.84 | 29 | 14.94 | 3188 | 1381 | 1.64 / 120.99 | 2 | 6 |
4 | 13 | 1473.48 | 17 | 14.96 | 2512 | 639 | 2.28 / 121.63 | 2 | 5 |
5 | 13 | 1046.76 | 17 | 15.00 | 1956 | 499 | 2.78 / 122.13 | 2 | 8 |
6 | 13 | 473.08 | 17 | 15.13 | 1142 | 294 | 3.07 / 122.43 | 2 | 5 |
7 | 13 | 52.80 | 17 | 15.25 | 479 | 124 | 3.19 / 122.55 | 2 | 4 |
8 | 8 | 0.04 | 165 | 15.21 | 384 | 964 | 4.16 / 123.51 | 2 | 7 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.56 | 26 | 15.19 | 549 | 217 | 0.22 / 115.38 | 2 | 2 |
2 | 10 | 1030.08 | 3 | 15.16 | 1962 | 89 | 0.31 / 115.46 | 2 | 3 |
3 | 3 | 967.80 | -1 | 15.51 | 0 | 0 | 0.09 / 115.46 | 2 | 3 |
4 | 7 | 2007.48 | 29 | 14.94 | 3186 | 1380 | 1.69 / 116.84 | 2 | 6 |
5 | 13 | 1473.48 | 17 | 14.96 | 2512 | 639 | 2.33 / 117.48 | 2 | 9 |
6 | 13 | 931.60 | 17 | 15.04 | 1782 | 456 | 2.78 / 117.94 | 2 | 8 |
7 | 13 | 523.16 | 17 | 15.12 | 1203 | 309 | 3.09 / 118.25 | 2 | 5 |
8 | 13 | 116.08 | 17 | 15.23 | 570 | 148 | 3.24 / 118.40 | 2 | 3 |
9 | 8 | 0.04 | 165 | 15.22 | 382 | 959 | 4.20 / 119.36 | 2 | 9 |
Average= | 3.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 28 | 15.19 | 527 | 224 | 0.22 / 111.16 | 2 | 2 |
2 | 3 | 961.28 | -1 | 15.51 | 0 | 0 | 0.00 / 111.16 | 2 | 2 |
3 | 3 | 977.92 | -1 | 15.53 | 0 | 0 | 0.00 / 111.16 | 2 | 2 |
4 | 7 | 2005.52 | 29 | 14.96 | 3183 | 1381 | 1.61 / 112.54 | 2 | 3 |
5 | 13 | 1590.20 | 17 | 14.95 | 2677 | 680 | 2.29 / 113.22 | 2 | 6 |
6 | 13 | 1005.36 | 17 | 15.03 | 1891 | 483 | 2.77 / 113.70 | 2 | 7 |
7 | 13 | 576.76 | 17 | 15.11 | 1284 | 330 | 3.10 / 114.03 | 2 | 6 |
8 | 13 | 138.20 | 17 | 15.23 | 618 | 160 | 3.26 / 114.19 | 2 | 6 |
9 | 8 | 0.04 | 165 | 15.22 | 384 | 964 | 4.22 / 115.16 | 2 | 9 |
Average= | 3.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.40 | 28 | 15.19 | 553 | 235 | 0.24 / 106.74 | 2 | 2 |
2 | 7 | 2002.96 | 29 | 14.95 | 3184 | 1380 | 1.62 / 108.12 | 2 | 4 |
3 | 13 | 1580.96 | 17 | 14.96 | 2645 | 673 | 2.29 / 108.80 | 2 | 4 |
4 | 13 | 1133.52 | 17 | 15.01 | 2056 | 525 | 2.81 / 109.32 | 2 | 9 |
5 | 13 | 559.56 | 17 | 15.12 | 1263 | 325 | 3.14 / 109.64 | 2 | 7 |
6 | 13 | 130.80 | 17 | 15.24 | 597 | 155 | 3.29 / 109.80 | 2 | 3 |
7 | 8 | 0.04 | 165 | 15.22 | 383 | 962 | 4.25 / 110.76 | 2 | 7 |
8 | 14 | 0.04 | 30 | 15.20 | 382 | 174 | 4.43 / 110.94 | 2 | 10 |
Average= | 3.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 28 | 15.20 | 537 | 229 | 0.23 / 102.56 | 2 | 2 |
2 | 7 | 2002.08 | 29 | 14.95 | 3176 | 1377 | 1.61 / 103.93 | 2 | 7 |
3 | 13 | 1600.08 | 17 | 14.95 | 2675 | 680 | 2.29 / 104.61 | 2 | 7 |
4 | 13 | 1015.24 | 17 | 15.04 | 1892 | 484 | 2.77 / 105.10 | 2 | 7 |
5 | 13 | 585.04 | 17 | 15.12 | 1296 | 333 | 3.10 / 105.43 | 2 | 4 |
6 | 13 | 71.40 | 17 | 15.26 | 499 | 129 | 3.23 / 105.56 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.23 | 377 | 947 | 4.18 / 106.51 | 2 | 7 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.00 | 28 | 15.20 | 548 | 233 | 0.23 / 98.37 | 2 | 2 |
2 | 7 | 2006.48 | 29 | 14.95 | 3185 | 1381 | 1.61 / 99.75 | 2 | 6 |
3 | 13 | 1596.52 | 17 | 14.96 | 2660 | 676 | 2.29 / 100.42 | 2 | 6 |
4 | 13 | 1030.36 | 17 | 15.04 | 1919 | 491 | 2.78 / 100.91 | 2 | 10 |
5 | 13 | 598.64 | 17 | 15.12 | 1304 | 335 | 3.12 / 101.25 | 2 | 7 |
6 | 13 | 77.80 | 17 | 15.26 | 519 | 135 | 3.25 / 101.38 | 2 | 4 |
7 | 8 | 0.04 | 165 | 15.23 | 376 | 945 | 4.20 / 102.33 | 2 | 5 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.56 | 28 | 15.20 | 533 | 227 | 0.23 / 94.18 | 2 | 3 |
2 | 7 | 2010.20 | 29 | 14.96 | 3182 | 1380 | 1.61 / 95.56 | 2 | 5 |
3 | 13 | 1579.92 | 17 | 14.97 | 2654 | 675 | 2.28 / 96.24 | 2 | 8 |
4 | 13 | 1003.36 | 17 | 15.04 | 1886 | 482 | 2.76 / 96.72 | 2 | 8 |
5 | 13 | 572.12 | 17 | 15.12 | 1278 | 328 | 3.09 / 97.05 | 2 | 6 |
6 | 13 | 72.92 | 17 | 15.26 | 516 | 134 | 3.23 / 97.18 | 2 | 4 |
7 | 8 | 0.08 | 165 | 15.24 | 378 | 951 | 4.18 / 98.13 | 2 | 8 |
Average= | 3.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.44 | 28 | 15.21 | 543 | 231 | 0.23 / 89.80 | 2 | 3 |
2 | 7 | 2006.12 | 29 | 14.98 | 3179 | 1381 | 1.61 / 91.19 | 2 | 4 |
3 | 13 | 1597.60 | 17 | 14.97 | 2668 | 679 | 2.29 / 91.86 | 2 | 5 |
4 | 13 | 1023.60 | 17 | 15.05 | 1888 | 483 | 2.77 / 92.35 | 2 | 8 |
5 | 13 | 595.56 | 17 | 15.13 | 1300 | 334 | 3.11 / 92.68 | 2 | 5 |
6 | 13 | 145.64 | 17 | 15.24 | 621 | 161 | 3.27 / 92.84 | 2 | 4 |
7 | 8 | -0.04 | 165 | 15.24 | 374 | 940 | 4.21 / 93.78 | 2 | 6 |
8 | 14 | -0.04 | 30 | 15.21 | 376 | 172 | 4.38 / 93.95 | 2 | 19 |
Average= | 3.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.92 | 28 | 15.21 | 551 | 235 | 0.23 / 85.60 | 2 | 2 |
2 | 3 | 1016.80 | 1 | 15.25 | 1959 | 30 | 0.26 / 85.63 | 2 | 3 |
3 | 7 | 2004.28 | 29 | 14.97 | 3169 | 1376 | 1.64 / 87.01 | 2 | 4 |
4 | 13 | 1583.64 | 17 | 14.98 | 2656 | 676 | 2.32 / 87.68 | 2 | 4 |
5 | 13 | 1004.20 | 17 | 15.05 | 1873 | 479 | 2.80 / 88.16 | 2 | 6 |
6 | 13 | 571.92 | 17 | 15.14 | 1265 | 326 | 3.12 / 88.49 | 2 | 4 |
7 | 13 | 74.96 | 17 | 15.27 | 517 | 134 | 3.26 / 88.62 | 2 | 4 |
8 | 8 | 0.12 | 165 | 15.24 | 378 | 951 | 4.21 / 89.57 | 2 | 8 |
Average= | 3.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.52 | 27 | 15.21 | 561 | 230 | 0.23 / 81.28 | 2 | 3 |
2 | 3 | 1018.08 | 1 | 15.26 | 2001 | 31 | 0.26 / 81.31 | 2 | 3 |
3 | 7 | 2004.60 | 29 | 14.98 | 3191 | 1386 | 1.65 / 82.70 | 2 | 4 |
4 | 13 | 1589.48 | 17 | 14.98 | 2660 | 677 | 2.32 / 83.38 | 2 | 5 |
5 | 13 | 1145.20 | 17 | 15.03 | 2072 | 529 | 2.85 / 83.91 | 2 | 6 |
6 | 13 | 672.24 | 17 | 15.11 | 1418 | 364 | 3.22 / 84.27 | 2 | 4 |
7 | 13 | 102.48 | 17 | 15.26 | 560 | 145 | 3.36 / 84.42 | 2 | 5 |
8 | 8 | -0.04 | 165 | 15.25 | 378 | 951 | 4.31 / 85.37 | 2 | 10 |
Average= | 3.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.16 | 27 | 15.23 | 509 | 209 | 0.21 / 77.07 | 2 | 3 |
2 | 10 | 1009.28 | 2 | 15.20 | 1902 | 58 | 0.27 / 77.13 | 2 | 3 |
3 | 3 | 957.88 | -1 | 15.53 | 0 | 0 | 0.06 / 77.13 | 2 | 3 |
4 | 7 | 2004.60 | 29 | 14.97 | 3170 | 1376 | 1.64 / 78.50 | 2 | 5 |
5 | 13 | 1575.12 | 17 | 14.98 | 2640 | 672 | 2.32 / 79.18 | 2 | 6 |
6 | 13 | 998.96 | 17 | 15.07 | 1862 | 477 | 2.79 / 79.65 | 2 | 6 |
7 | 13 | 460.80 | 17 | 15.18 | 1100 | 284 | 3.08 / 79.94 | 2 | 4 |
8 | 13 | 81.80 | 17 | 15.27 | 536 | 139 | 3.22 / 80.08 | 2 | 3 |
9 | 8 | 0.04 | 165 | 15.25 | 388 | 976 | 4.19 / 81.05 | 2 | 12 |
Average= | 3.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 27 | 15.23 | 488 | 201 | 0.20 / 73.09 | 2 | 2 |
2 | 3 | 981.04 | -1 | 15.54 | 0 | 0 | 0.00 / 73.09 | 2 | 2 |
3 | 7 | 2002.24 | 29 | 14.98 | 3153 | 1370 | 1.57 / 74.46 | 2 | 5 |
4 | 13 | 1462.16 | 17 | 15.01 | 2475 | 632 | 2.20 / 75.09 | 2 | 6 |
5 | 13 | 1050.60 | 17 | 15.05 | 1919 | 491 | 2.69 / 75.58 | 2 | 6 |
6 | 13 | 487.40 | 17 | 15.17 | 1119 | 289 | 2.98 / 75.87 | 2 | 4 |
7 | 13 | 56.72 | 17 | 15.29 | 454 | 118 | 3.10 / 75.99 | 2 | 2 |
8 | 8 | 0.24 | 165 | 15.26 | 347 | 874 | 3.97 / 76.86 | 2 | 10 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.32 | 27 | 15.24 | 501 | 206 | 0.21 / 69.06 | 2 | 3 |
2 | 7 | 2006.04 | 29 | 14.98 | 3163 | 1374 | 1.58 / 70.44 | 2 | 3 |
3 | 13 | 1572.48 | 17 | 15.00 | 2613 | 666 | 2.25 / 71.10 | 2 | 4 |
4 | 13 | 1006.84 | 17 | 15.07 | 1855 | 475 | 2.72 / 71.58 | 2 | 6 |
5 | 13 | 574.72 | 17 | 15.15 | 1245 | 321 | 3.04 / 71.90 | 2 | 6 |
6 | 13 | 70.72 | 17 | 15.29 | 469 | 122 | 3.16 / 72.02 | 2 | 3 |
7 | 8 | -0.04 | 165 | 15.27 | 343 | 864 | 4.03 / 72.89 | 2 | 7 |
Average= | 3.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 27 | 15.24 | 493 | 203 | 0.20 / 65.00 | 2 | 2 |
2 | 3 | 1027.36 | 1 | 15.25 | 1980 | 30 | 0.23 / 65.03 | 2 | 3 |
3 | 7 | 2003.24 | 29 | 14.99 | 3164 | 1375 | 1.61 / 66.41 | 2 | 3 |
4 | 13 | 1594.92 | 17 | 15.00 | 2645 | 674 | 2.28 / 67.08 | 2 | 6 |
5 | 13 | 1011.76 | 17 | 15.07 | 1863 | 477 | 2.76 / 67.56 | 2 | 5 |
6 | 13 | 574.12 | 17 | 15.15 | 1256 | 323 | 3.08 / 67.88 | 2 | 4 |
7 | 13 | 72.56 | 17 | 15.29 | 469 | 122 | 3.21 / 68.01 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.27 | 338 | 852 | 4.06 / 68.86 | 2 | 7 |
Average= | 3.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.16 | 28 | 15.24 | 484 | 207 | 0.21 / 61.00 | 2 | 3 |
2 | 3 | 978.84 | -1 | 15.57 | 0 | 0 | 0.00 / 61.00 | 2 | 3 |
3 | 7 | 2003.52 | 29 | 15.00 | 3174 | 1381 | 1.59 / 62.38 | 2 | 4 |
4 | 13 | 1572.24 | 17 | 15.01 | 2623 | 669 | 2.26 / 63.05 | 2 | 4 |
5 | 13 | 990.00 | 17 | 15.08 | 1830 | 469 | 2.73 / 63.52 | 2 | 7 |
6 | 13 | 457.32 | 17 | 15.19 | 1067 | 276 | 3.00 / 63.79 | 2 | 4 |
7 | 13 | 80.80 | 17 | 15.29 | 498 | 129 | 3.13 / 63.92 | 2 | 3 |
8 | 8 | 0.32 | 165 | 15.27 | 349 | 879 | 4.01 / 64.80 | 2 | 8 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.28 | 28 | 15.24 | 509 | 217 | 0.22 / 56.85 | 2 | 3 |
2 | 7 | 2003.88 | 29 | 15.00 | 3166 | 1377 | 1.59 / 58.22 | 2 | 3 |
3 | 13 | 1564.28 | 17 | 15.01 | 2605 | 665 | 2.26 / 58.89 | 2 | 3 |
4 | 13 | 1004.08 | 17 | 15.08 | 1845 | 473 | 2.73 / 59.36 | 2 | 6 |
5 | 13 | 571.20 | 17 | 15.16 | 1245 | 321 | 3.05 / 59.68 | 2 | 4 |
6 | 13 | 70.32 | 17 | 15.29 | 482 | 125 | 3.18 / 59.81 | 2 | 3 |
7 | 13 | 19.32 | 17 | 15.30 | 400 | 104 | 3.28 / 59.91 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.27 | 349 | 879 | 4.16 / 60.79 | 2 | 6 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.00 | 28 | 15.25 | 503 | 215 | 0.21 / 52.92 | 2 | 3 |
2 | 7 | 2003.32 | 29 | 15.00 | 3157 | 1373 | 1.59 / 54.29 | 2 | 3 |
3 | 13 | 1443.00 | 17 | 15.03 | 2450 | 626 | 2.21 / 54.92 | 2 | 3 |
4 | 13 | 901.04 | 17 | 15.10 | 1706 | 438 | 2.65 / 55.36 | 2 | 4 |
5 | 13 | 493.28 | 17 | 15.19 | 1126 | 291 | 2.94 / 55.65 | 2 | 4 |
6 | 13 | 49.24 | 17 | 15.30 | 437 | 114 | 3.06 / 55.76 | 2 | 3 |
7 | 8 | 0.20 | 165 | 15.28 | 345 | 870 | 3.93 / 56.63 | 2 | 6 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.44 | 28 | 15.25 | 502 | 214 | 0.21 / 48.81 | 2 | 3 |
2 | 7 | 2002.68 | 29 | 15.00 | 3165 | 1377 | 1.59 / 50.19 | 2 | 3 |
3 | 13 | 1433.44 | 17 | 15.03 | 2437 | 623 | 2.21 / 50.81 | 2 | 3 |
4 | 13 | 1003.52 | 17 | 15.08 | 1859 | 477 | 2.69 / 51.28 | 2 | 4 |
5 | 13 | 567.24 | 17 | 15.17 | 1243 | 321 | 3.01 / 51.61 | 2 | 4 |
6 | 13 | 63.96 | 17 | 15.30 | 469 | 122 | 3.13 / 51.73 | 2 | 4 |
7 | 13 | 17.84 | 17 | 15.31 | 390 | 102 | 3.23 / 51.83 | 2 | 4 |
8 | 8 | -0.04 | 165 | 15.27 | 347 | 874 | 4.11 / 52.70 | 2 | 7 |
Average= | 3.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.44 | 28 | 15.25 | 501 | 214 | 0.21 / 44.67 | 2 | 3 |
2 | 7 | 2003.16 | 30 | 15.00 | 3158 | 1421 | 1.64 / 46.09 | 2 | 2 |
3 | 13 | 1578.00 | 16 | 15.02 | 2625 | 631 | 2.27 / 46.72 | 2 | 3 |
4 | 13 | 1003.80 | 16 | 15.09 | 1855 | 448 | 2.71 / 47.16 | 2 | 4 |
5 | 13 | 580.48 | 16 | 15.17 | 1263 | 307 | 3.02 / 47.47 | 2 | 4 |
6 | 13 | 145.76 | 16 | 15.28 | 597 | 146 | 3.17 / 47.62 | 2 | 3 |
7 | 13 | 28.40 | 16 | 15.31 | 417 | 102 | 3.27 / 47.72 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.28 | 347 | 875 | 4.14 / 48.59 | 2 | 8 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.28 | 28 | 15.26 | 491 | 210 | 0.21 / 40.55 | 2 | 3 |
2 | 7 | 2004.68 | 30 | 15.00 | 3157 | 1421 | 1.63 / 41.97 | 2 | 2 |
3 | 13 | 1582.80 | 16 | 15.02 | 2643 | 635 | 2.27 / 42.60 | 2 | 3 |
4 | 13 | 991.04 | 16 | 15.11 | 1827 | 442 | 2.71 / 43.05 | 2 | 4 |
5 | 13 | 571.24 | 16 | 15.18 | 1236 | 300 | 3.01 / 43.35 | 2 | 4 |
6 | 13 | 134.04 | 16 | 15.29 | 564 | 138 | 3.15 / 43.48 | 2 | 3 |
7 | 13 | 12.80 | 16 | 15.32 | 389 | 95 | 3.24 / 43.58 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.28 | 346 | 872 | 4.11 / 44.45 | 2 | 7 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.68 | 28 | 15.26 | 487 | 208 | 0.21 / 36.43 | 2 | 3 |
2 | 7 | 2005.76 | 29 | 15.02 | 3155 | 1374 | 1.58 / 37.81 | 2 | 3 |
3 | 13 | 1588.88 | 16 | 15.03 | 2629 | 632 | 2.21 / 38.44 | 2 | 3 |
4 | 13 | 1136.12 | 16 | 15.08 | 2031 | 490 | 2.70 / 38.93 | 2 | 4 |
5 | 13 | 561.40 | 16 | 15.18 | 1231 | 299 | 3.00 / 39.23 | 2 | 4 |
6 | 13 | 139.96 | 16 | 15.29 | 586 | 143 | 3.15 / 39.37 | 2 | 4 |
7 | 13 | 29.40 | 16 | 15.31 | 418 | 102 | 3.25 / 39.47 | 2 | 3 |
8 | 8 | 0.12 | 165 | 15.28 | 343 | 865 | 4.11 / 40.34 | 2 | 9 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.52 | 28 | 15.25 | 501 | 214 | 0.21 / 32.40 | 2 | 2 |
2 | 7 | 2002.08 | 29 | 15.01 | 3159 | 1375 | 1.59 / 33.78 | 2 | 3 |
3 | 13 | 1575.36 | 16 | 15.04 | 2615 | 629 | 2.22 / 34.41 | 2 | 3 |
4 | 13 | 995.36 | 16 | 15.11 | 1841 | 445 | 2.66 / 34.85 | 2 | 4 |
5 | 13 | 582.12 | 16 | 15.18 | 1252 | 304 | 2.97 / 35.15 | 2 | 4 |
6 | 13 | 143.48 | 16 | 15.30 | 580 | 142 | 3.11 / 35.30 | 2 | 2 |
7 | 13 | 13.64 | 16 | 15.32 | 368 | 90 | 3.20 / 35.39 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.29 | 332 | 838 | 4.04 / 36.22 | 2 | 7 |
Average= | 3.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.12 | 28 | 15.26 | 494 | 211 | 0.21 / 28.32 | 2 | 2 |
2 | 7 | 2005.84 | 29 | 15.02 | 3157 | 1375 | 1.59 / 29.69 | 2 | 3 |
3 | 13 | 1458.48 | 16 | 15.06 | 2476 | 597 | 2.18 / 30.29 | 2 | 3 |
4 | 13 | 1039.20 | 16 | 15.10 | 1893 | 457 | 2.64 / 30.75 | 2 | 4 |
5 | 13 | 605.92 | 16 | 15.17 | 1293 | 314 | 2.95 / 31.06 | 2 | 4 |
6 | 13 | 156.12 | 16 | 15.29 | 607 | 148 | 3.10 / 31.21 | 2 | 3 |
7 | 13 | 27.24 | 16 | 15.31 | 408 | 100 | 3.20 / 31.31 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.28 | 348 | 877 | 4.08 / 32.19 | 2 | 8 |
Average= | 3.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.40 | 27 | 15.26 | 507 | 209 | 0.21 / 24.35 | 2 | 2 |
2 | 3 | 1015.84 | 1 | 15.29 | 1949 | 30 | 0.24 / 24.38 | 2 | 3 |
3 | 7 | 2003.16 | 29 | 15.02 | 3150 | 1372 | 1.61 / 25.75 | 2 | 3 |
4 | 13 | 1438.68 | 16 | 15.06 | 2433 | 586 | 2.20 / 26.34 | 2 | 4 |
5 | 13 | 1025.68 | 16 | 15.11 | 1884 | 455 | 2.65 / 26.79 | 2 | 4 |
6 | 13 | 593.64 | 16 | 15.18 | 1269 | 308 | 2.96 / 27.10 | 2 | 4 |
7 | 13 | 149.44 | 16 | 15.29 | 593 | 145 | 3.11 / 27.25 | 2 | 3 |
8 | 8 | 0.16 | 165 | 15.29 | 341 | 860 | 3.97 / 28.11 | 2 | 8 |
Average= | 3.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.76 | 26 | 15.27 | 495 | 197 | 0.20 / 20.21 | 2 | 2 |
2 | 3 | 1046.36 | 2 | 15.27 | 2000 | 61 | 0.26 / 20.28 | 2 | 2 |
3 | 7 | 2004.36 | 38 | 14.97 | 3131 | 1781 | 2.04 / 22.06 | 2 | 3 |
4 | 13 | 1253.04 | 18 | 15.08 | 2171 | 589 | 2.63 / 22.65 | 2 | 3 |
5 | 13 | 798.24 | 18 | 15.14 | 1544 | 421 | 3.05 / 23.07 | 2 | 4 |
6 | 13 | 228.52 | 18 | 15.28 | 700 | 193 | 3.24 / 23.26 | 2 | 3 |
7 | 8 | 0.12 | 165 | 15.30 | 349 | 881 | 4.12 / 24.14 | 2 | 8 |
Average= | 3.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.60 | 23 | 15.27 | 502 | 176 | 0.18 / 16.11 | 2 | 2 |
2 | 10 | 1044.04 | 3 | 15.23 | 1936 | 88 | 0.26 / 16.20 | 2 | 2 |
3 | 3 | 1031.76 | 1 | 15.28 | 1958 | 30 | 0.29 / 16.23 | 2 | 2 |
4 | 7 | 2004.48 | 38 | 14.98 | 3116 | 1774 | 2.07 / 18.00 | 2 | 2 |
5 | 13 | 1256.28 | 18 | 15.08 | 2179 | 591 | 2.66 / 18.59 | 2 | 3 |
6 | 13 | 683.08 | 18 | 15.17 | 1383 | 378 | 3.04 / 18.97 | 2 | 3 |
7 | 13 | 249.96 | 18 | 15.28 | 731 | 201 | 3.24 / 19.17 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.30 | 335 | 846 | 4.08 / 20.02 | 2 | 6 |
Average= | 3.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.52 | 29 | 15.27 | 494 | 219 | 0.22 / 12.57 | 2 | 3 |
2 | 3 | 929.28 | -1 | 15.57 | 0 | 0 | 0.00 / 12.57 | 2 | 3 |
3 | 3 | 970.24 | -1 | 15.59 | 0 | 0 | 0.00 / 12.57 | 2 | 3 |
4 | 7 | 1519.16 | 39 | 15.10 | 2477 | 1459 | 1.68 / 14.03 | 2 | 3 |
5 | 13 | 1117.84 | 18 | 15.13 | 1970 | 537 | 2.21 / 14.57 | 2 | 3 |
6 | 13 | 680.04 | 18 | 15.19 | 1374 | 376 | 2.59 / 14.94 | 2 | 3 |
7 | 13 | 113.20 | 18 | 15.32 | 526 | 145 | 2.73 / 15.09 | 2 | 3 |
8 | 8 | 0.04 | 165 | 15.31 | 335 | 846 | 3.58 / 15.93 | 2 | 8 |
Average= | 3.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.28 | 27 | 15.27 | 494 | 204 | 0.20 / 9.05 | 2 | 2 |
2 | 7 | 1525.84 | 38 | 15.10 | 2489 | 1428 | 1.63 / 10.48 | 2 | 2 |
3 | 13 | 1114.48 | 18 | 15.14 | 1965 | 536 | 2.17 / 11.02 | 2 | 3 |
4 | 13 | 674.80 | 18 | 15.19 | 1361 | 372 | 2.54 / 11.39 | 2 | 3 |
5 | 13 | 109.76 | 18 | 15.32 | 507 | 140 | 2.68 / 11.53 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.31 | 327 | 826 | 3.51 / 12.35 | 2 | 5 |
Average= | 3.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.60 | 24 | 15.30 | 506 | 186 | 0.19 / 4.99 | 2 | 3 |
2 | 10 | 1025.96 | 3 | 15.25 | 1898 | 87 | 0.27 / 5.08 | 2 | 2 |
3 | 7 | 1514.28 | 74 | 15.02 | 2463 | 2738 | 3.01 / 7.82 | 2 | 2 |
4 | 13 | 244.84 | 18 | 15.30 | 718 | 198 | 3.21 / 8.02 | 2 | 3 |
5 | 8 | 0.12 | 165 | 15.31 | 329 | 831 | 4.04 / 8.85 | 2 | 7 |
Average= | 2.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 23 | 15.49 | 435 | 155 | 0.15 / 1.74 | 3 | 3 |
2 | 10 | 1018.16 | 4 | 15.31 | 1855 | 114 | 0.27 / 1.86 | 2 | 2 |
3 | 3 | 1061.12 | 2 | 15.30 | 1978 | 61 | 0.33 / 1.92 | 2 | 2 |
4 | 3 | 1021.48 | 1 | 15.33 | 1962 | 30 | 0.36 / 1.95 | 2 | 2 |
5 | 7 | 1003.28 | 74 | 15.15 | 1779 | 1994 | 2.35 / 3.94 | 2 | 3 |
6 | 8 | 0.04 | 165 | 15.34 | 342 | 866 | 3.22 / 4.81 | 2 | 6 |
Average= | 2.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 84.72 | 22 | 15.62 | 403 | 138 | 0.14 / 0.14 | 3 | 3 |
2 | 7 | 97.88 | 74 | 15.59 | 407 | 470 | 0.61 / 0.61 | 3 | 3 |
3 | 8 | 0.16 | 240 | 15.55 | 263 | 982 | 1.59 / 1.59 | 3 | 8 |
Average= | 1.59 (KJ/cycle) |