SIO Argo Site:
Pump Diagnostics Page   



Serial= 4017 WMO= 1902666

Return

←PreviousNext→

Cycle 28 GMT 23/12/2024 22:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.92 50 14.69 440 323 0.32 / 144.00 2 8
2 8 2008.96 58 14.42 2844 2379 2.70 / 146.37 2 7
3 14 1511.56 16 14.53 2247 522 3.22 / 146.90 2 9
4 14 1272.96 16 14.56 1938 451 3.68 / 147.35 2 10
5 14 933.32 16 14.63 1498 351 4.03 / 147.70 2 12
6 14 614.48 16 14.72 1084 255 4.28 / 147.95 2 14
7 14 379.60 16 14.75 773 182 4.46 / 148.14 2 16
8 14 94.20 16 14.81 401 95 4.56 / 148.23 2 17
9 14 64.20 16 14.81 359 85 4.64 / 148.32 2 19
10 9 -0.12 185 14.80 254 695 5.34 / 149.01 3 51
11 15 -0.08 35 14.79 213 110 5.45 / 149.12 24 248
Average= 5.14
(KJ/cycle)

Cycle 27 GMT 13/12/2024 18:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.52 50 14.65 429 314 0.31 / 138.58 2 8
2 8 2005.16 58 14.43 2832 2370 2.68 / 140.95 2 6
3 14 1455.88 16 14.54 2167 504 3.19 / 141.45 2 9
4 14 1173.60 16 14.59 1809 422 3.61 / 141.88 2 10
5 14 890.88 16 14.65 1445 339 3.95 / 142.21 2 12
6 14 654.44 16 14.70 1138 268 4.22 / 142.48 2 14
7 14 372.00 16 14.77 764 181 4.40 / 142.66 2 15
8 14 125.60 16 14.81 444 105 4.50 / 142.77 2 17
9 14 52.44 16 14.80 345 82 4.58 / 142.85 2 18
10 9 0.24 189 14.81 259 725 5.31 / 143.57 2 65
11 15 0.20 31 14.79 215 99 5.41 / 143.67 25 248
Average= 5.13
(KJ/cycle)

Cycle 26 GMT 3/12/2024 15:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 123.16 50 14.68 439 322 0.32 / 133.12 2 10
2 8 2005.96 58 14.42 2842 2377 2.70 / 135.50 2 6
3 14 1509.20 16 14.53 2231 519 3.22 / 136.02 2 9
4 14 1222.40 16 14.57 1872 436 3.65 / 136.45 2 10
5 14 936.40 16 14.63 1500 351 4.01 / 136.80 2 12
6 14 695.36 16 14.69 1187 279 4.28 / 137.08 2 14
7 14 404.20 16 14.76 808 191 4.48 / 137.27 2 16
8 14 116.28 16 14.81 429 102 4.58 / 137.37 2 17
9 14 45.80 16 14.81 330 78 4.66 / 137.45 2 19
10 9 -0.28 185 14.81 256 701 5.36 / 138.15 3 53
11 15 -0.28 35 14.80 212 110 5.47 / 138.26 26 248
Average= 5.12
(KJ/cycle)

Cycle 25 GMT 23/11/2024 12: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 123.64 49 14.73 439 317 0.32 / 127.60 2 9
2 11 1010.24 2 14.71 1654 49 0.37 / 127.65 2 8
3 8 2008.56 58 14.44 2829 2369 2.73 / 130.02 2 7
4 14 1483.36 16 14.54 2197 511 3.25 / 130.53 2 9
5 14 1249.48 16 14.57 1902 443 3.69 / 130.98 2 10
6 14 961.68 16 14.64 1527 358 4.05 / 131.33 2 12
7 14 641.96 16 14.72 1112 262 4.31 / 131.60 2 14
8 14 403.60 16 14.77 803 190 4.50 / 131.79 2 16
9 14 113.48 16 14.83 427 101 4.60 / 131.89 2 18
10 14 43.72 16 14.81 331 78 4.68 / 131.97 2 19
11 9 0.28 187 14.82 262 726 5.40 / 132.69 2 56
12 15 0.08 33 14.80 216 105 5.51 / 132.80 27 248
Average= 5.11
(KJ/cycle)

Cycle 24 GMT 13/11/2024 21: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.48 49 14.76 434 314 0.31 / 122.11 2 9
2 11 1008.04 2 14.73 1658 49 0.36 / 122.16 2 9
3 8 2005.96 59 14.44 2843 2422 2.78 / 124.58 2 6
4 14 1454.16 16 14.56 2157 502 3.29 / 125.08 2 8
5 14 1221.12 16 14.59 1860 434 3.72 / 125.52 2 10
6 14 904.52 16 14.66 1455 341 4.06 / 125.86 2 11
7 14 665.64 16 14.71 1146 270 4.33 / 126.13 2 13
8 14 345.40 16 14.78 727 172 4.50 / 126.30 2 15
9 14 107.36 16 14.83 415 98 4.60 / 126.40 2 17
10 14 45.92 16 14.83 331 79 4.68 / 126.48 2 18
11 9 0.12 185 14.82 257 705 5.39 / 127.18 3 198
12 15 -0.08 35 14.81 208 108 5.49 / 127.29 28 248
Average= 5.09
(KJ/cycle)

Cycle 23 GMT 3/11/2024 9:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 124.00 50 14.72 433 319 0.32 / 116.64 2 8
2 8 2007.28 58 14.44 2837 2376 2.69 / 119.02 2 6
3 14 1473.48 16 14.57 2189 510 3.21 / 119.53 2 8
4 14 1226.40 16 14.60 1875 438 3.64 / 119.97 2 9
5 14 919.84 16 14.66 1484 348 3.99 / 120.32 2 11
6 14 682.84 16 14.71 1173 276 4.27 / 120.59 2 12
7 14 396.92 16 14.78 797 188 4.46 / 120.78 2 14
8 14 115.52 16 14.83 432 103 4.56 / 120.88 2 16
9 14 50.48 16 14.84 343 81 4.64 / 120.96 2 17
10 9 -0.12 187 14.83 262 727 5.37 / 121.69 2 248
11 15 -0.40 33 14.82 211 103 5.47 / 121.79 105 248
Average= 5.07
(KJ/cycle)

Cycle 22 GMT 24/10/2024 6:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 125.04 50 14.75 439 324 0.32 / 111.07 2 7
2 3 1018.28 1 14.80 1663 25 0.35 / 111.09 2 4
3 8 2010.64 58 14.45 2829 2371 2.72 / 113.46 2 6
4 14 1513.28 16 14.56 2237 521 3.24 / 113.98 2 9
5 14 1255.60 16 14.60 1896 443 3.68 / 114.43 2 10
6 14 980.80 16 14.63 1551 363 4.05 / 114.79 2 12
7 14 696.16 16 14.70 1179 277 4.32 / 115.07 2 13
8 14 408.48 16 14.77 805 190 4.51 / 115.26 2 15
9 14 162.56 16 14.82 491 116 4.63 / 115.37 2 17
10 14 48.20 16 14.82 334 79 4.71 / 115.45 2 18
11 14 13.68 16 14.85 285 68 4.78 / 115.52 2 19
12 9 0.20 170 14.82 259 653 5.43 / 116.17 2 51
13 15 0.20 50 14.81 206 153 5.58 / 116.32 23 248
Average= 5.06
(KJ/cycle)

Cycle 21 GMT 14/10/2024 3:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 122.60 50 14.74 431 318 0.32 / 105.67 2 7
2 8 2005.48 58 14.46 2828 2372 2.69 / 108.05 2 7
3 14 1402.60 16 14.58 2090 488 3.18 / 108.53 2 9
4 14 1210.60 16 14.61 1838 430 3.61 / 108.96 2 10
5 14 886.32 16 14.67 1434 337 3.94 / 109.30 2 12
6 14 643.88 16 14.72 1114 262 4.21 / 109.56 2 14
7 14 363.28 16 14.79 750 177 4.38 / 109.74 2 15
8 14 92.16 16 14.82 398 94 4.48 / 109.83 2 17
9 14 59.60 16 14.82 353 84 4.56 / 109.92 2 19
10 9 0.68 185 14.83 261 716 5.28 / 110.63 2 131
11 15 0.00 35 14.81 210 109 5.39 / 110.74 28 248
Average= 5.03
(KJ/cycle)

Cycle 20 GMT 4/10/2024 0:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.92 50 14.74 425 313 0.31 / 100.22 2 7
2 3 1017.52 1 14.80 1649 24 0.34 / 100.24 2 4
3 8 2008.40 59 14.45 2837 2419 2.76 / 102.66 2 6
4 14 1471.12 16 14.57 2174 507 3.26 / 103.17 2 8
5 14 1167.56 16 14.62 1791 419 3.68 / 103.59 2 10
6 14 888.20 16 14.67 1433 336 4.02 / 103.92 2 11
7 14 642.40 16 14.72 1115 263 4.28 / 104.19 2 12
8 14 355.96 16 14.79 744 176 4.46 / 104.36 2 14
9 14 107.04 16 14.83 418 99 4.56 / 104.46 2 17
10 14 39.20 16 14.84 325 77 4.63 / 104.54 2 18
11 9 0.24 185 14.83 259 711 5.34 / 105.25 2 81
12 15 0.04 35 14.82 208 108 5.45 / 105.36 25 248
Average= 5.02
(KJ/cycle)

Cycle 19 GMT 23/ 9/2024 21:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 123.36 50 14.78 424 313 0.31 / 94.75 2 7
2 8 2005.64 58 14.47 2830 2375 2.69 / 97.12 2 7
3 14 1475.08 16 14.58 2195 512 3.20 / 97.64 2 9
4 14 1155.96 16 14.62 1786 418 3.62 / 98.05 2 11
5 14 955.40 16 14.65 1520 356 3.97 / 98.41 2 12
6 14 636.32 16 14.73 1109 261 4.24 / 98.67 2 13
7 14 353.72 16 14.80 743 176 4.41 / 98.85 2 15
8 14 116.16 16 14.84 427 101 4.51 / 98.95 2 17
9 14 44.40 16 14.84 334 79 4.59 / 99.03 2 18
10 14 13.84 16 14.85 285 68 4.66 / 99.10 2 20
11 9 0.88 168 14.83 261 650 5.31 / 99.75 3 57
12 15 -0.20 52 14.82 205 158 5.47 / 99.90 23 248
Average= 5.00
(KJ/cycle)

Cycle 18 GMT 13/ 9/2024 16:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.68 48 14.77 424 301 0.30 / 89.21 2 7
2 11 1009.00 3 14.74 1646 73 0.37 / 89.28 2 8
3 8 2007.56 58 14.47 2828 2373 2.75 / 91.65 2 7
4 14 1413.92 16 14.58 2111 492 3.24 / 92.14 2 9
5 14 1217.20 16 14.61 1863 435 3.67 / 92.58 2 10
6 14 907.68 16 14.69 1454 342 4.02 / 92.92 2 12
7 14 706.40 16 14.71 1199 282 4.30 / 93.20 2 13
8 14 383.00 16 14.80 780 185 4.48 / 93.39 2 15
9 14 101.64 16 14.86 409 97 4.58 / 93.49 2 17
10 14 41.64 16 14.87 325 77 4.66 / 93.56 2 18
11 14 13.80 16 14.86 286 68 4.73 / 93.63 2 20
12 9 0.72 168 14.84 260 648 5.37 / 94.28 3 58
13 15 0.12 52 14.83 203 157 5.53 / 94.44 22 248
Average= 4.97
(KJ/cycle)

Cycle 17 GMT 4/ 9/2024 0:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 122.84 48 14.77 424 301 0.30 / 83.70 2 8
2 11 1018.44 2 14.75 1670 49 0.35 / 83.74 2 9
3 8 2005.52 58 14.47 2832 2377 2.73 / 86.12 2 7
4 14 1483.64 16 14.58 2203 514 3.24 / 86.64 2 9
5 14 1209.12 16 14.60 1850 432 3.67 / 87.07 2 10
6 14 921.00 16 14.67 1474 346 4.02 / 87.41 2 12
7 14 612.76 16 14.75 1077 254 4.27 / 87.67 2 14
8 14 363.88 16 14.81 752 178 4.45 / 87.85 2 15
9 14 123.04 16 14.85 440 105 4.56 / 87.95 2 17
10 14 51.00 16 14.86 340 81 4.64 / 88.03 2 19
11 14 15.68 16 14.86 289 69 4.71 / 88.10 2 20
12 9 0.80 170 14.84 259 653 5.36 / 88.75 2 237
13 15 -0.16 50 14.83 204 151 5.51 / 88.90 63 248
Average= 4.94
(KJ/cycle)

Cycle 16 GMT 24/ 8/2024 11:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 122.56 49 14.78 431 312 0.31 / 78.15 2 7
2 11 1001.08 2 14.74 1651 49 0.36 / 78.20 2 8
3 8 2005.28 58 14.47 2837 2381 2.74 / 80.58 2 8
4 14 1474.92 16 14.58 2195 512 3.25 / 81.09 2 10
5 14 1228.68 16 14.62 1885 441 3.69 / 81.53 2 11
6 14 990.72 16 14.66 1572 369 4.06 / 81.90 2 12
7 14 657.04 16 14.74 1134 267 4.33 / 82.17 2 14
8 14 374.12 16 14.81 767 182 4.51 / 82.35 2 16
9 14 102.80 16 14.87 408 97 4.61 / 82.45 2 18
10 14 41.32 16 14.87 324 77 4.69 / 82.53 2 19
11 14 11.28 16 14.87 281 67 4.75 / 82.59 2 21
12 9 0.00 168 14.85 259 646 5.40 / 83.24 3 53
13 15 -0.24 52 14.84 203 157 5.56 / 83.40 24 248
Average= 4.91
(KJ/cycle)

Cycle 15 GMT 14/ 8/2024 7: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.88 49 14.76 434 314 0.31 / 72.67 2 6
2 3 1019.44 1 14.85 1669 25 0.34 / 72.69 2 4
3 8 2007.96 59 14.47 2849 2432 2.77 / 75.13 2 6
4 14 1468.24 16 14.58 2188 510 3.28 / 75.64 2 9
5 14 1186.72 16 14.63 1827 428 3.71 / 76.06 2 11
6 14 865.56 16 14.69 1407 331 4.04 / 76.39 2 12
7 14 634.84 16 14.75 1112 262 4.30 / 76.66 2 13
8 14 388.24 16 14.80 792 188 4.49 / 76.84 2 15
9 14 104.44 16 14.86 413 98 4.59 / 76.94 2 16
10 14 36.04 16 14.85 317 75 4.66 / 77.02 2 17
11 9 0.12 183 14.86 260 707 5.37 / 77.72 2 67
12 15 -0.08 37 14.84 208 114 5.48 / 77.84 23 248
Average= 4.86
(KJ/cycle)

Cycle 14 GMT 4/ 8/2024 2:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.20 49 14.78 434 314 0.31 / 67.22 2 7
2 11 1003.24 2 14.77 1640 48 0.36 / 67.27 2 8
3 8 2006.04 58 14.47 2834 2378 2.74 / 69.64 2 8
4 14 1390.68 16 14.60 2080 486 3.23 / 70.13 2 11
5 14 1236.84 16 14.62 1890 442 3.67 / 70.57 2 12
6 14 950.00 16 14.67 1514 355 4.02 / 70.93 2 13
7 14 586.36 16 14.77 1044 247 4.27 / 71.17 2 15
8 14 346.04 16 14.82 734 174 4.45 / 71.35 2 17
9 14 108.60 16 14.87 419 100 4.55 / 71.45 2 18
10 14 41.24 16 14.88 326 78 4.62 / 71.53 2 20
11 9 0.08 183 14.86 262 712 5.34 / 72.24 2 68
12 15 -0.04 37 14.85 211 116 5.45 / 72.35 24 248
Average= 4.82
(KJ/cycle)

Cycle 13 GMT 24/ 7/2024 22: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 123.96 48 14.78 441 313 0.31 / 61.74 2 8
2 3 1036.44 1 14.83 1684 25 0.34 / 61.76 2 8
3 8 2009.60 58 14.49 2840 2387 2.72 / 64.15 2 7
4 14 1522.72 16 14.58 2249 525 3.25 / 64.68 2 8
5 14 1240.92 16 14.61 1909 446 3.70 / 65.12 2 10
6 14 912.32 16 14.70 1465 345 4.04 / 65.47 2 12
7 14 637.88 16 14.76 1113 263 4.30 / 65.73 2 13
8 14 310.32 16 14.82 685 162 4.47 / 65.89 2 14
9 14 113.32 16 14.86 426 101 4.57 / 65.99 2 16
10 14 41.92 16 14.88 330 79 4.65 / 66.07 2 17
11 9 0.24 183 14.86 263 715 5.36 / 66.79 2 231
12 15 0.12 37 14.85 211 116 5.48 / 66.90 23 248
Average= 4.78
(KJ/cycle)

Cycle 12 GMT 14/ 7/2024 17:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 48 14.80 406 288 0.29 / 56.18 2 8
2 11 1006.24 2 14.76 1663 49 0.34 / 56.23 2 8
3 8 2006.80 58 14.50 2838 2387 2.72 / 58.61 2 7
4 14 1476.76 16 14.59 2196 513 3.24 / 59.13 2 9
5 14 1205.84 16 14.64 1855 435 3.67 / 59.56 2 11
6 14 957.32 16 14.68 1518 357 4.03 / 59.92 2 12
7 14 639.04 16 14.76 1109 262 4.29 / 60.18 2 13
8 14 392.76 16 14.81 793 188 4.48 / 60.37 2 15
9 14 84.72 16 14.89 388 92 4.57 / 60.46 2 16
10 14 53.48 16 14.88 346 82 4.65 / 60.54 2 18
11 14 15.68 16 14.89 289 69 4.72 / 60.61 2 20
12 9 -0.20 168 14.86 263 657 5.38 / 61.27 2 57
13 15 0.00 52 14.85 205 158 5.54 / 61.43 23 248
Average= 4.73
(KJ/cycle)

Cycle 11 GMT 4/ 7/2024 13: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.76 48 14.78 434 308 0.31 / 50.41 2 8
2 3 1043.36 1 14.82 1706 25 0.33 / 50.44 2 8
3 3 1019.08 1 14.87 1688 25 0.36 / 50.46 2 5
4 8 2006.56 59 14.49 2837 2425 2.78 / 52.89 2 8
5 14 1546.72 16 14.58 2276 531 3.31 / 53.42 2 10
6 14 1320.04 16 14.60 1999 467 3.78 / 53.89 2 12
7 14 1048.84 16 14.65 1636 383 4.17 / 54.27 2 13
8 14 769.04 16 14.72 1278 301 4.47 / 54.57 2 14
9 14 540.04 16 14.77 981 232 4.70 / 54.80 2 16
10 14 185.64 16 14.85 521 124 4.82 / 54.93 2 17
11 14 55.08 16 14.87 347 83 4.90 / 55.01 2 19
12 14 14.36 16 14.87 290 69 4.97 / 55.08 2 21
13 9 0.20 168 14.85 263 656 5.63 / 55.73 3 248
14 15 0.12 52 14.84 203 157 5.79 / 55.89 179 248
Average= 4.66
(KJ/cycle)

Cycle 10 GMT 24/ 6/2024 21: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.96 48 14.58 443 310 0.31 / 44.76 2 8
2 11 1001.52 2 14.62 1654 48 0.36 / 44.81 2 8
3 8 2004.96 58 14.49 2836 2383 2.74 / 47.19 2 7
4 14 1535.88 16 14.58 2268 529 3.27 / 47.72 2 10
5 14 1313.68 16 14.60 1982 463 3.73 / 48.19 2 11
6 14 961.32 16 14.68 1530 359 4.09 / 48.54 2 12
7 14 785.80 16 14.71 1305 307 4.40 / 48.85 2 13
8 14 465.44 16 14.78 884 209 4.61 / 49.06 2 15
9 14 196.88 16 14.85 535 127 4.74 / 49.19 2 16
10 14 62.52 16 14.88 357 85 4.82 / 49.27 2 18
11 9 0.48 183 14.86 263 715 5.54 / 49.99 2 57
12 15 -0.08 37 14.84 212 116 5.65 / 50.10 22 248
Average= 4.55
(KJ/cycle)

Cycle 9 GMT 14/ 6/2024 8:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.68 48 14.60 440 308 0.31 / 37.60 2 10
2 8 1907.52 150 14.17 2700 5739 6.05 / 43.34 2 11
3 14 239.36 16 14.64 597 140 6.19 / 43.48 2 16
4 14 62.32 16 14.67 362 85 6.27 / 43.56 2 18
5 14 17.20 16 14.67 296 69 6.34 / 43.63 2 20
6 9 0.56 174 14.65 266 678 7.02 / 44.31 3 67
7 15 0.12 46 14.64 209 141 7.16 / 44.45 24 248
Average= 4.45
(KJ/cycle)

Cycle 8 GMT 13/ 6/2024 22:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.56 45 14.65 439 289 0.29 / 30.94 2 6
2 11 1013.92 2 14.66 1647 48 0.34 / 30.98 2 6
3 3 1016.44 1 14.73 1662 24 0.36 / 31.01 2 3
4 8 1710.88 150 14.26 2458 5258 5.62 / 36.27 2 8
5 14 139.80 16 14.67 465 109 5.73 / 36.37 2 14
6 14 55.16 16 14.69 350 82 5.81 / 36.46 2 15
7 9 0.16 185 14.67 266 722 6.53 / 37.18 2 51
8 15 0.00 35 14.66 218 112 6.65 / 37.29 21 248
Average= 4.14
(KJ/cycle)

Cycle 7 GMT 13/ 6/2024 13:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.80 45 14.71 439 291 0.29 / 25.10 2 8
2 3 1036.64 1 14.75 1723 25 0.32 / 25.12 2 7
3 3 1022.16 1 14.79 1679 25 0.34 / 25.15 2 5
4 8 1414.84 150 14.41 2085 4507 4.85 / 29.65 2 12
5 14 97.00 16 14.74 406 96 4.94 / 29.75 2 16
6 14 29.52 16 14.74 313 74 5.02 / 29.82 2 18
7 9 0.12 178 14.73 264 692 5.71 / 30.52 2 70
8 15 -0.12 42 14.71 211 130 5.84 / 30.65 24 248
Average= 3.83
(KJ/cycle)

Cycle 6 GMT 13/ 6/2024 5:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.04 46 14.75 429 291 0.29 / 20.01 2 9
2 11 1004.16 2 14.74 1644 48 0.34 / 20.06 2 8
3 8 1144.48 150 14.58 1748 3823 4.16 / 23.88 2 13
4 14 69.76 16 14.82 371 88 4.25 / 23.97 2 17
5 9 0.60 187 14.80 264 731 4.98 / 24.70 2 74
6 15 0.00 33 14.79 217 106 5.09 / 24.81 24 248
Average= 3.54
(KJ/cycle)

Cycle 5 GMT 12/ 6/2024 17:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.28 45 14.80 429 286 0.29 / 14.94 2 7
2 11 1005.04 2 14.80 1652 49 0.33 / 14.99 2 6
3 8 1137.72 150 14.61 1738 3809 4.14 / 18.80 2 11
4 14 74.64 16 14.85 373 89 4.23 / 18.88 2 16
5 9 0.80 187 14.83 263 729 4.96 / 19.61 2 66
6 15 0.12 33 14.82 215 105 5.07 / 19.72 23 248
Average= 3.29
(KJ/cycle)

Cycle 4 GMT 12/ 6/2024 6:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.32 71 14.83 434 457 0.46 / 11.22 2 10
2 11 500.84 2 14.90 944 28 0.49 / 11.25 2 11
3 8 654.24 151 14.79 1124 2510 3.00 / 13.76 2 15
4 14 21.92 16 14.89 300 71 3.07 / 13.83 2 18
5 9 0.12 174 14.87 261 675 3.74 / 14.51 2 51
6 15 -0.12 46 14.86 210 144 3.89 / 14.65 22 248
Average= 2.93
(KJ/cycle)

Cycle 3 GMT 12/ 6/2024 1:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.28 70 14.85 427 444 0.44 / 7.36 2 8
2 11 517.96 2 14.95 970 29 0.47 / 7.39 2 9
3 8 652.96 150 14.82 1122 2494 2.97 / 9.88 2 13
4 14 19.92 16 14.91 296 71 3.04 / 9.95 2 16
5 9 0.00 176 14.90 261 684 3.72 / 10.64 2 66
6 15 0.20 44 14.89 201 132 3.85 / 10.77 22 248
Average= 2.69
(KJ/cycle)

Cycle 2 GMT 11/ 6/2024 20:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.84 86 14.91 423 542 0.54 / 4.91 2 10
2 8 251.56 150 14.92 572 1280 1.82 / 6.19 2 20
3 9 0.04 99 14.93 254 375 2.20 / 6.57 3 54
4 15 -0.04 121 14.92 191 345 2.54 / 6.91 24 248
Average= 2.30
(KJ/cycle)

Cycle 1 GMT 11/ 6/2024 19:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 86 15.07 407 527 0.53 / 2.50 2 9
2 8 221.68 150 15.03 523 1179 1.71 / 3.68 2 19
3 9 -0.16 97 15.01 244 355 2.06 / 4.03 4 126
4 15 -0.08 123 15.01 182 336 2.40 / 4.37 24 248
Average= 2.19
(KJ/cycle)

Cycle 0 GMT 11/ 6/2024 17:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 95.28 108 15.30 362 598 0.60 / 0.60 3 8
2 8 106.96 151 15.24 340 782 1.38 / 1.38 3 18
3 9 0.08 69 15.22 216 227 1.61 / 1.61 5 117
4 15 0.20 151 15.21 159 365 1.97 / 1.97 24 247
Average= 1.97