SIO Argo Site:
Pump Diagnostics Page   



Serial= 4014 WMO= 1902372

Return

←PreviousNext→

Cycle 27 GMT 5/ 5/2025 12:44:12

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 45 14.87 393 263 0.26 / 139.77 3 3
2 8 1529.08 58 14.63 2336 1982 2.25 / 141.75 2 3
3 14 -99.00 30 14.64 1926 846 3.09 / 142.60 2 4
4 9 1220.00 300 14.25 1834 7840 10.93 / 150.44 2 20
Average= 13.68
(KJ/cycle)

Cycle 26 GMT 4/ 5/2025 5:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 45 14.74 405 269 0.27 / 134.01 2 3
2 8 1526.92 58 14.65 2329 1979 2.25 / 135.99 2 3
3 14 1489.44 30 14.58 2279 997 3.24 / 136.99 2 3
4 14 1129.44 30 14.63 1796 788 4.03 / 137.78 2 4
5 14 636.60 30 14.75 1128 499 4.53 / 138.28 2 6
6 14 129.32 30 14.90 439 196 4.73 / 138.47 2 6
7 14 79.52 30 14.92 367 164 4.89 / 138.64 2 8
8 14 25.28 30 14.92 280 125 5.02 / 138.76 2 10
9 9 0.20 165 14.91 239 588 5.61 / 139.35 2 54
10 15 0.16 55 14.90 193 158 5.76 / 139.51 36 246
Average= 13.95
(KJ/cycle)

Cycle 25 GMT 2/ 5/2025 21:17:17

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 44 14.72 411 266 0.27 / 123.90 2 3
2 11 1000.04 2 14.83 1684 50 0.32 / 123.95 2 3
3 8 1512.80 58 14.66 2314 1968 2.28 / 125.92 2 3
4 9 1199.48 300 14.33 1820 7824 10.11 / 133.74 2 18
Average= 14.86
(KJ/cycle)

Cycle 24 GMT 1/ 5/2025 13:54:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 44 14.86 391 256 0.26 / 113.31 3 3
2 8 1535.96 58 14.63 2334 1980 2.24 / 115.29 2 3
3 9 1298.92 300 14.27 1949 8344 10.58 / 123.64 2 16
Average= 15.45
(KJ/cycle)

Cycle 23 GMT 30/ 4/2025 6:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 44 15.00 385 254 0.25 / 107.63 3 3
2 8 1531.56 58 14.63 2333 1980 2.23 / 109.61 2 3
3 14 1495.76 30 14.56 2272 992 3.23 / 110.61 2 3
4 14 1122.56 30 14.61 1785 782 4.01 / 111.39 2 5
5 14 528.88 30 14.78 982 435 4.44 / 111.82 2 6
6 14 146.12 30 14.88 461 206 4.65 / 112.03 2 6
7 14 69.96 30 14.91 355 159 4.81 / 112.19 2 8
8 14 23.80 30 14.92 276 124 4.93 / 112.31 2 10
9 9 -0.04 165 14.91 239 588 5.52 / 112.90 2 54
10 15 -0.12 55 14.89 189 155 5.67 / 113.06 34 246
Average= 16.15
(KJ/cycle)

Cycle 22 GMT 28/ 4/2025 22:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 44 14.99 393 259 0.26 / 101.22 3 3
2 8 -99.00 58 14.37 2967 2473 2.73 / 103.70 2 3
3 14 1668.28 30 14.43 2525 1093 3.83 / 104.79 2 3
4 14 1161.24 30 14.61 1840 806 4.63 / 105.60 2 5
5 14 638.36 30 14.82 1139 506 5.14 / 106.10 2 6
6 14 142.28 30 15.04 457 206 5.34 / 106.31 2 6
7 14 79.84 30 15.06 372 168 5.51 / 106.48 2 8
8 14 31.92 30 15.08 293 133 5.64 / 106.61 2 10
9 9 0.12 168 15.05 243 614 6.26 / 107.23 2 50
10 15 -0.04 52 15.04 199 156 6.41 / 107.38 33 246
Average= 17.90
(KJ/cycle)

Cycle 21 GMT 27/ 4/2025 11:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 44 15.00 389 257 0.26 / 94.74 3 3
2 8 -99.00 59 14.37 2973 2521 2.78 / 97.26 2 3
3 14 1679.40 30 14.42 2532 1095 3.87 / 98.35 2 4
4 14 1175.56 30 14.60 1867 818 4.69 / 99.17 2 5
5 14 654.24 30 14.81 1162 516 5.21 / 99.69 2 6
6 14 146.52 30 15.04 463 209 5.42 / 99.90 2 6
7 14 87.92 30 15.06 382 173 5.59 / 100.07 2 8
8 14 34.68 30 15.07 296 134 5.72 / 100.20 2 9
9 9 0.04 170 15.05 241 617 6.34 / 100.82 2 56
10 15 -0.12 50 15.03 196 147 6.49 / 100.97 36 246
Average= 20.19
(KJ/cycle)

Cycle 20 GMT 26/ 4/2025 0:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 44 15.02 391 258 0.26 / 88.29 3 3
2 8 -99.00 59 14.36 2958 2506 2.76 / 90.79 2 3
3 14 1632.24 30 14.44 2463 1067 3.83 / 91.86 2 4
4 14 1238.52 30 14.56 1946 850 4.68 / 92.71 2 5
5 14 686.64 30 14.79 1198 532 5.21 / 93.24 2 6
6 14 107.60 30 15.06 409 185 5.40 / 93.43 2 6
7 14 86.44 30 15.07 378 171 5.57 / 93.60 2 8
8 14 33.04 30 15.09 290 131 5.70 / 93.73 2 9
9 9 0.00 170 15.07 237 607 6.31 / 94.33 2 53
10 15 -0.12 50 15.05 193 145 6.45 / 94.48 34 246
Average= 23.62
(KJ/cycle)

Cycle 19 GMT 24/ 4/2025 13: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 44 14.85 387 253 0.25 / 82.13 3 3
2 8 -99.00 58 14.42 2865 2396 2.65 / 84.52 2 3
3 14 1680.32 25 14.46 2537 917 3.57 / 85.44 2 3
4 14 1288.24 25 14.58 2022 737 4.30 / 86.18 2 5
5 14 790.32 25 14.77 1346 497 4.80 / 86.68 2 6
6 14 215.12 25 15.03 560 210 5.01 / 86.89 2 6
7 14 81.08 25 15.08 370 139 5.15 / 87.03 2 6
8 14 78.28 25 15.08 364 137 5.29 / 87.16 2 7
9 14 27.36 25 15.10 283 107 5.39 / 87.27 2 8
10 9 0.04 172 15.08 238 617 6.01 / 87.89 2 50
11 15 0.00 48 15.06 194 140 6.15 / 88.03 32 246
Average= 29.34
(KJ/cycle)

Cycle 18 GMT 23/ 4/2025 14:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 44 14.88 387 253 0.25 / 75.95 3 3
2 8 1913.64 59 14.42 2844 2420 2.67 / 78.37 2 3
3 14 1754.76 25 14.40 2625 945 3.62 / 79.32 2 3
4 14 1235.92 25 14.53 1951 709 4.33 / 80.02 2 4
5 14 736.44 25 14.70 1276 469 4.80 / 80.49 2 6
6 14 243.08 25 14.86 599 223 5.02 / 80.72 2 6
7 14 85.84 25 14.91 379 141 5.16 / 80.86 2 6
8 14 82.84 25 14.90 373 139 5.30 / 81.00 2 7
9 14 50.68 25 14.91 320 119 5.42 / 81.11 2 8
10 9 0.00 176 14.90 240 629 6.05 / 81.74 2 54
11 15 -0.12 44 14.88 201 132 6.18 / 81.88 35 246
Average= 40.94
(KJ/cycle)

Cycle 17 GMT 22/ 4/2025 16:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 44 15.32 371 250 0.25 / 69.89 3 3
2 8 1907.80 58 14.40 2833 2366 2.62 / 72.26 2 3
3 14 1602.48 25 14.43 2438 880 3.50 / 73.14 2 3
4 14 1265.72 25 14.50 1988 721 4.22 / 73.86 2 4
5 14 755.08 25 14.67 1297 476 4.69 / 74.33 2 5
6 14 257.84 25 14.85 620 230 4.92 / 74.56 2 5
7 14 77.40 25 14.92 368 137 5.06 / 74.70 2 6
8 14 74.24 25 14.92 358 134 5.19 / 74.83 2 6
9 14 25.72 25 14.93 280 105 5.30 / 74.94 2 7
10 9 -0.08 176 14.92 238 625 5.92 / 75.56 2 52
11 15 -0.16 44 14.91 203 133 6.06 / 75.70 32 246
Average= 75.70
(KJ/cycle)

Cycle 11 GMT 21/ 4/2025 11:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 44 15.00 390 257 0.26 / 62.87 3 3
2 8 1907.28 58 14.42 2823 2361 2.62 / 65.23 2 3
3 14 1603.36 25 14.43 2429 876 3.49 / 66.11 2 4
4 14 1266.80 25 14.49 1982 718 4.21 / 66.83 2 5
5 14 759.00 25 14.66 1300 476 4.69 / 67.30 2 6
6 14 -99.00 25 15.02 430 161 4.85 / 67.47 2 6
7 14 -99.00 25 15.06 358 135 4.99 / 67.60 2 5
8 14 -99.00 25 15.08 311 117 5.10 / 67.72 2 6
9 14 -99.00 25 15.14 224 85 5.19 / 67.80 3 7
10 14 -99.00 25 15.16 219 83 5.27 / 67.89 3 7
11 14 -99.00 25 15.18 212 80 5.35 / 67.97 3 9
12 14 -99.00 25 15.21 210 80 5.43 / 68.05 3 10
13 14 -99.00 25 15.22 207 79 5.51 / 68.12 4 12
14 14 -99.00 25 15.24 203 77 5.59 / 68.20 4 15
15 14 -99.00 25 15.25 203 77 5.66 / 68.28 5 20
16 14 -99.00 25 15.28 202 77 5.74 / 68.36 12 42
17 14 -99.00 25 15.30 179 68 5.81 / 68.43 27 246
18 14 -99.00 25 15.32 142 54 5.86 / 68.48 245 245
19 14 -99.00 25 15.33 140 54 5.92 / 68.53 245 245
20 14 -99.00 25 15.35 138 53 5.97 / 68.59 245 245
21 14 -99.00 25 15.35 137 53 6.02 / 68.64 245 245
22 14 -99.00 25 15.35 139 53 6.08 / 68.69 245 245
23 14 -99.00 25 15.36 139 53 6.13 / 68.75 245 245
24 14 -99.00 25 15.37 139 53 6.18 / 68.80 245 245
25 14 -99.00 25 15.37 140 54 6.24 / 68.85 245 245
26 14 -99.00 25 15.38 140 54 6.29 / 68.91 245 245
27 14 -99.00 25 15.37 140 54 6.34 / 68.96 245 245
28 14 -99.00 25 15.38 140 54 6.40 / 69.01 245 245
29 14 -99.00 25 15.39 142 55 6.45 / 69.07 245 245
30 14 -99.00 25 15.38 138 53 6.51 / 69.12 245 245
31 14 -99.00 25 15.38 139 53 6.56 / 69.18 245 245
32 15 0.04 220 15.35 138 466 7.03 / 69.64 245 245
Average= 5.80
(KJ/cycle)

Cycle 10 GMT 20/ 4/2025 6: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 44 15.02 390 258 0.26 / 56.76 3 3
2 8 -99.00 58 14.43 2857 2391 2.65 / 59.15 2 3
3 14 1609.52 25 14.49 2437 883 3.53 / 60.03 2 4
4 14 1130.88 25 14.66 1804 661 4.19 / 60.69 2 5
5 14 805.60 25 14.78 1368 505 4.70 / 61.20 2 6
6 14 299.92 25 14.99 676 253 4.95 / 61.45 2 6
7 14 85.88 25 15.09 379 143 5.09 / 61.59 2 7
8 14 80.68 25 15.08 363 137 5.23 / 61.73 2 8
9 14 47.76 25 15.09 315 119 5.35 / 61.85 2 10
10 9 0.00 170 15.07 239 612 5.96 / 62.46 2 54
11 15 -0.08 50 15.05 204 154 6.12 / 62.62 35 246
Average= 5.69
(KJ/cycle)

Cycle 9 GMT 19/ 4/2025 7:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 44 14.84 385 251 0.25 / 50.60 3 3
2 3 1018.12 1 14.95 1706 26 0.28 / 50.62 2 2
3 8 -99.00 58 14.42 2867 2398 2.67 / 53.02 2 3
4 14 1613.16 25 14.49 2454 889 3.56 / 53.91 2 4
5 14 1268.52 25 14.59 1990 726 4.29 / 54.63 2 4
6 14 755.40 25 14.80 1297 480 4.77 / 55.11 2 6
7 14 264.60 25 15.01 629 236 5.01 / 55.35 2 6
8 14 84.80 25 15.10 380 143 5.15 / 55.49 2 7
9 14 80.00 25 15.09 369 139 5.29 / 55.63 2 8
10 14 27.52 25 15.11 285 108 5.40 / 55.74 2 10
11 9 0.16 170 15.08 237 608 6.00 / 56.35 2 50
12 15 -0.04 50 15.07 202 152 6.16 / 56.50 33 246
Average= 5.65
(KJ/cycle)

Cycle 8 GMT 18/ 4/2025 9:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 44 15.03 379 251 0.25 / 44.33 3 3
2 8 2003.24 70 14.35 2962 2975 3.23 / 47.31 2 3
3 14 1488.52 25 14.46 2286 826 4.05 / 48.14 2 4
4 14 987.32 25 14.61 1608 587 4.64 / 48.72 2 5
5 14 652.36 25 14.71 1154 424 5.06 / 49.15 2 6
6 14 146.44 25 14.87 462 172 5.24 / 49.32 2 6
7 14 79.72 25 14.88 369 137 5.37 / 49.46 2 8
8 14 48.04 25 14.87 312 116 5.49 / 49.57 2 8
9 9 0.04 191 14.88 238 676 6.17 / 50.25 2 52
10 15 -0.16 29 14.86 221 95 6.26 / 50.34 35 246
Average= 5.59
(KJ/cycle)

Cycle 7 GMT 17/ 4/2025 10: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 44 15.05 391 259 0.26 / 38.13 3 3
2 8 -99.00 70 14.35 2962 2975 3.23 / 41.10 2 3
3 14 1498.80 25 14.52 2298 834 4.07 / 41.94 2 4
4 14 1008.48 25 14.71 1639 603 4.67 / 42.54 2 5
5 14 514.00 25 14.92 971 362 5.03 / 42.90 2 6
6 14 105.56 25 15.10 410 155 5.19 / 43.06 2 6
7 14 75.36 25 15.11 360 136 5.32 / 43.19 2 7
8 14 40.76 25 15.13 302 114 5.44 / 43.31 2 8
9 9 0.12 185 15.11 237 662 6.10 / 43.97 2 52
10 15 -0.04 35 15.08 214 113 6.21 / 44.08 34 246
Average= 5.51
(KJ/cycle)

Cycle 6 GMT 16/ 4/2025 10:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 44 14.85 387 253 0.25 / 31.90 3 3
2 8 -99.00 70 14.35 2958 2971 3.22 / 34.87 2 3
3 14 1491.64 25 14.52 2287 830 4.05 / 35.70 2 4
4 14 990.96 25 14.71 1616 594 4.65 / 36.30 2 5
5 14 517.28 25 14.91 972 362 5.01 / 36.66 2 6
6 14 180.28 25 15.06 509 192 5.20 / 36.85 2 6
7 14 73.20 25 15.10 361 136 5.34 / 36.99 2 7
8 14 39.84 25 15.11 305 115 5.45 / 37.10 2 8
9 9 0.00 187 15.10 233 658 6.11 / 37.76 2 52
10 15 -0.12 33 15.08 215 107 6.22 / 37.87 34 246
Average= 5.41
(KJ/cycle)

Cycle 5 GMT 15/ 4/2025 11:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 44 14.87 371 243 0.24 / 25.88 3 3
2 8 1906.36 71 14.42 2818 2885 3.13 / 28.77 2 3
3 14 1395.48 25 14.51 2150 780 3.91 / 29.55 2 4
4 14 911.84 25 14.65 1502 550 4.46 / 30.10 2 5
5 14 579.84 25 14.75 1049 387 4.84 / 30.49 2 6
6 14 124.92 25 14.89 428 159 5.00 / 30.65 2 6
7 14 79.92 25 14.89 364 135 5.14 / 30.78 2 7
8 14 40.36 25 14.89 299 111 5.25 / 30.89 2 8
9 9 0.08 187 14.89 233 649 5.90 / 31.54 2 51
10 15 0.00 33 14.87 221 108 6.01 / 31.65 34 246
Average= 5.28
(KJ/cycle)

Cycle 4 GMT 14/ 4/2025 12:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 45 14.89 383 257 0.26 / 19.04 3 3
2 8 1719.96 145 14.41 2566 5362 5.62 / 24.40 2 4
3 14 247.20 20 14.88 596 177 5.80 / 24.58 2 6
4 14 79.36 20 14.93 362 108 5.90 / 24.69 2 6
5 14 76.76 20 14.93 352 105 6.01 / 24.80 2 7
6 14 54.04 20 14.92 317 95 6.10 / 24.89 2 7
7 9 0.04 191 14.91 230 655 6.76 / 25.54 2 50
8 15 -0.12 29 14.88 226 98 6.86 / 25.64 35 246
Average= 5.13
(KJ/cycle)

Cycle 3 GMT 13/ 4/2025 14:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 45 14.92 377 253 0.25 / 12.74 3 3
2 3 970.36 -1 15.36 1 0 0.00 / 12.74 3 3
3 8 1520.72 145 14.54 2299 4847 5.10 / 17.58 2 4
4 14 144.20 20 14.94 452 135 5.24 / 17.72 2 6
5 14 83.96 20 14.96 368 110 5.35 / 17.83 2 6
6 14 83.00 20 14.96 361 108 5.45 / 17.94 2 7
7 14 53.72 20 14.96 317 95 5.55 / 18.03 2 8
8 9 0.04 187 14.96 231 646 6.19 / 18.68 2 54
9 15 -0.08 33 14.94 219 108 6.30 / 18.79 37 246
Average= 4.70
(KJ/cycle)

Cycle 2 GMT 12/ 4/2025 16:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 45 14.90 371 249 0.25 / 6.48 3 3
2 3 953.84 -1 15.37 0 0 0.00 / 6.48 3 3
3 3 964.12 -1 15.36 1 0 0.00 / 6.48 3 3
4 8 1525.76 145 14.48 2301 4831 5.08 / 11.31 2 4
5 14 132.72 20 14.94 432 129 5.21 / 11.44 2 5
6 14 73.16 20 14.97 349 104 5.31 / 11.54 2 6
7 14 70.40 20 14.96 342 102 5.42 / 11.64 2 7
8 14 46.40 20 14.96 303 91 5.51 / 11.73 2 8
9 9 0.16 187 14.96 231 646 6.15 / 12.38 2 53
10 15 0.16 33 14.94 212 105 6.26 / 12.48 37 246
Average= 4.16
(KJ/cycle)

Cycle 1 GMT 12/ 4/2025 8:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 45 15.09 360 244 0.24 / 2.06 3 3
2 3 938.20 -1 15.42 1 0 0.00 / 2.06 3 3
3 3 958.24 -1 15.41 1 0 0.00 / 2.06 3 3
4 8 982.28 145 14.76 1550 3317 3.56 / 5.37 2 6
5 14 64.52 20 14.94 330 99 3.66 / 5.47 2 7
6 9 0.64 191 14.94 231 659 4.32 / 6.13 2 50
7 15 -0.28 29 14.92 223 96 4.42 / 6.23 34 246
Average= 3.11
(KJ/cycle)

Cycle 0 GMT 12/ 4/2025 3:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 45 15.37 378 261 0.26 / 0.26 3 3
2 8 140.64 145 15.30 399 885 1.15 / 1.15 3 4
3 9 0.28 193 15.21 200 587 1.73 / 1.73 3 57
4 15 0.08 27 15.18 188 77 1.81 / 1.81 43 246
Average= 1.81