SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 30 | 14.97 | 400 | 180 | 0.18 / 446.29 | 3 | 3 |
2 | 7 | 2010.04 | 30 | 14.84 | 2905 | 1293 | 1.47 / 447.58 | 2 | 2 |
3 | 13 | 1742.60 | 20 | 14.82 | 2576 | 764 | 2.24 / 448.35 | 2 | 3 |
4 | 13 | 1123.24 | 20 | 14.86 | 1800 | 535 | 2.77 / 448.88 | 2 | 3 |
5 | 13 | 536.24 | 20 | 14.96 | 1025 | 307 | 3.08 / 449.19 | 2 | 3 |
6 | 13 | 139.08 | 20 | 15.02 | 456 | 137 | 3.22 / 449.32 | 2 | 2 |
7 | 13 | 33.68 | 20 | 15.05 | 308 | 93 | 3.31 / 449.42 | 2 | 2 |
8 | 8 | -0.04 | 165 | 15.02 | 254 | 629 | 3.94 / 450.05 | 2 | 4 |
9 | 14 | -0.04 | 30 | 14.99 | 254 | 114 | 4.05 / 450.16 | 2 | 8 |
Average= | 450.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 29 | 14.97 | 404 | 175 | 0.18 / 442.45 | 3 | 3 |
2 | 7 | 2004.64 | 30 | 14.85 | 2897 | 1291 | 1.47 / 443.74 | 2 | 3 |
3 | 13 | 1610.12 | 20 | 14.85 | 2422 | 719 | 2.19 / 444.46 | 2 | 2 |
4 | 13 | 1029.64 | 20 | 14.90 | 1678 | 500 | 2.69 / 444.96 | 2 | 2 |
5 | 13 | 445.32 | 20 | 15.00 | 896 | 269 | 2.95 / 445.23 | 2 | 2 |
6 | 13 | 73.48 | 20 | 15.06 | 367 | 111 | 3.06 / 445.34 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.04 | 262 | 650 | 3.71 / 445.99 | 2 | 4 |
8 | 14 | 0.08 | 30 | 15.01 | 260 | 117 | 3.83 / 446.11 | 2 | 5 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 29 | 14.99 | 392 | 170 | 0.17 / 438.74 | 3 | 3 |
2 | 7 | 2005.16 | 30 | 14.87 | 2902 | 1295 | 1.46 / 440.04 | 2 | 2 |
3 | 13 | 1599.92 | 20 | 14.85 | 2406 | 715 | 2.18 / 440.75 | 2 | 2 |
4 | 13 | 1030.20 | 20 | 14.91 | 1677 | 500 | 2.68 / 441.25 | 2 | 2 |
5 | 13 | 444.56 | 20 | 15.01 | 894 | 268 | 2.95 / 441.52 | 2 | 2 |
6 | 13 | 83.84 | 20 | 15.07 | 383 | 115 | 3.06 / 441.64 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.04 | 258 | 640 | 3.70 / 442.28 | 2 | 3 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.48 | 29 | 15.00 | 399 | 174 | 0.17 / 435.11 | 2 | 3 |
2 | 7 | 2005.96 | 30 | 14.88 | 2901 | 1295 | 1.47 / 436.41 | 2 | 2 |
3 | 13 | 1592.24 | 20 | 14.87 | 2400 | 714 | 2.18 / 437.12 | 2 | 2 |
4 | 13 | 1004.84 | 20 | 14.91 | 1650 | 492 | 2.67 / 437.61 | 2 | 3 |
5 | 13 | 293.40 | 20 | 15.05 | 686 | 206 | 2.88 / 437.82 | 2 | 2 |
6 | 13 | 85.16 | 20 | 15.06 | 384 | 116 | 3.00 / 437.94 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.04 | 257 | 638 | 3.63 / 438.57 | 2 | 7 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.40 | 29 | 15.00 | 412 | 179 | 0.18 / 431.40 | 3 | 3 |
2 | 7 | 2002.56 | 30 | 14.89 | 2902 | 1296 | 1.48 / 432.69 | 2 | 3 |
3 | 13 | 1599.80 | 20 | 14.87 | 2409 | 716 | 2.19 / 433.41 | 2 | 3 |
4 | 13 | 1037.80 | 20 | 14.91 | 1693 | 505 | 2.70 / 433.91 | 2 | 2 |
5 | 13 | 436.76 | 20 | 15.02 | 889 | 267 | 2.96 / 434.18 | 2 | 2 |
6 | 13 | 68.84 | 20 | 15.09 | 365 | 110 | 3.07 / 434.29 | 2 | 2 |
7 | 8 | -0.04 | 165 | 15.05 | 261 | 648 | 3.72 / 434.94 | 2 | 5 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 29 | 14.99 | 402 | 175 | 0.17 / 427.65 | 3 | 3 |
2 | 7 | 2005.84 | 30 | 14.87 | 2902 | 1295 | 1.47 / 428.94 | 2 | 2 |
3 | 13 | 1729.68 | 20 | 14.83 | 2573 | 763 | 2.23 / 429.71 | 2 | 3 |
4 | 13 | 997.76 | 20 | 14.91 | 1645 | 491 | 2.72 / 430.20 | 2 | 2 |
5 | 13 | 430.28 | 20 | 15.00 | 882 | 265 | 2.99 / 430.46 | 2 | 2 |
6 | 13 | 64.92 | 20 | 15.06 | 356 | 107 | 3.09 / 430.57 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.04 | 261 | 648 | 3.74 / 431.22 | 2 | 5 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.88 | 29 | 15.00 | 401 | 174 | 0.17 / 423.93 | 2 | 3 |
2 | 7 | 2008.08 | 30 | 14.88 | 2915 | 1301 | 1.48 / 425.23 | 2 | 3 |
3 | 13 | 1599.28 | 20 | 14.87 | 2408 | 716 | 2.19 / 425.94 | 2 | 3 |
4 | 13 | 1031.20 | 20 | 14.91 | 1689 | 504 | 2.70 / 426.45 | 2 | 3 |
5 | 13 | 446.92 | 20 | 15.02 | 903 | 271 | 2.97 / 426.72 | 2 | 3 |
6 | 13 | 72.12 | 20 | 15.07 | 366 | 110 | 3.08 / 426.83 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.03 | 260 | 645 | 3.72 / 427.47 | 2 | 3 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 29 | 15.01 | 401 | 175 | 0.17 / 420.21 | 2 | 3 |
2 | 7 | 2008.04 | 30 | 14.88 | 2907 | 1298 | 1.47 / 421.51 | 2 | 3 |
3 | 13 | 1604.28 | 20 | 14.86 | 2414 | 717 | 2.19 / 422.23 | 2 | 2 |
4 | 13 | 1025.88 | 20 | 14.92 | 1676 | 500 | 2.69 / 422.73 | 2 | 2 |
5 | 13 | 430.72 | 20 | 15.02 | 878 | 264 | 2.95 / 422.99 | 2 | 2 |
6 | 13 | 64.76 | 20 | 15.08 | 359 | 108 | 3.06 / 423.10 | 2 | 2 |
7 | 8 | -0.04 | 165 | 15.04 | 262 | 650 | 3.71 / 423.75 | 2 | 5 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 29 | 15.01 | 409 | 178 | 0.18 / 416.51 | 3 | 3 |
2 | 7 | 2006.48 | 30 | 14.89 | 2901 | 1296 | 1.47 / 417.80 | 2 | 2 |
3 | 13 | 1599.56 | 20 | 14.86 | 2399 | 713 | 2.19 / 418.52 | 2 | 2 |
4 | 13 | 1021.48 | 20 | 14.92 | 1666 | 497 | 2.68 / 419.01 | 2 | 2 |
5 | 13 | 435.24 | 20 | 15.02 | 884 | 266 | 2.95 / 419.28 | 2 | 2 |
6 | 13 | 69.88 | 20 | 15.07 | 365 | 110 | 3.06 / 419.39 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.05 | 262 | 651 | 3.71 / 420.04 | 2 | 5 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.60 | 29 | 15.00 | 408 | 177 | 0.18 / 412.75 | 3 | 3 |
2 | 7 | 2004.44 | 30 | 14.89 | 2897 | 1294 | 1.47 / 414.04 | 2 | 2 |
3 | 13 | 1736.92 | 20 | 14.84 | 2577 | 765 | 2.24 / 414.81 | 2 | 3 |
4 | 13 | 1009.36 | 20 | 14.91 | 1653 | 493 | 2.73 / 415.30 | 2 | 3 |
5 | 13 | 435.48 | 20 | 15.02 | 890 | 267 | 3.00 / 415.57 | 2 | 2 |
6 | 13 | 65.92 | 20 | 15.08 | 361 | 109 | 3.11 / 415.68 | 2 | 2 |
7 | 8 | -0.04 | 165 | 15.06 | 262 | 651 | 3.76 / 416.33 | 2 | 3 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 29 | 15.00 | 408 | 177 | 0.18 / 408.97 | 2 | 3 |
2 | 7 | 2005.04 | 31 | 14.88 | 2903 | 1339 | 1.52 / 410.31 | 2 | 2 |
3 | 13 | 1596.24 | 20 | 14.86 | 2399 | 713 | 2.23 / 411.03 | 2 | 3 |
4 | 13 | 1143.52 | 20 | 14.90 | 1829 | 545 | 2.77 / 411.57 | 2 | 3 |
5 | 13 | 397.48 | 20 | 15.02 | 835 | 251 | 3.03 / 411.82 | 2 | 2 |
6 | 13 | 60.44 | 20 | 15.07 | 353 | 106 | 3.13 / 411.93 | 2 | 2 |
7 | 8 | 0.20 | 165 | 15.04 | 260 | 645 | 3.78 / 412.57 | 2 | 7 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 29 | 14.97 | 408 | 177 | 0.18 / 405.23 | 3 | 3 |
2 | 7 | 2004.36 | 30 | 14.88 | 2886 | 1288 | 1.47 / 406.52 | 2 | 3 |
3 | 13 | 1595.44 | 20 | 14.87 | 2397 | 713 | 2.18 / 407.24 | 2 | 2 |
4 | 13 | 1156.92 | 20 | 14.88 | 1846 | 549 | 2.73 / 407.78 | 2 | 3 |
5 | 13 | 412.36 | 20 | 15.04 | 854 | 257 | 2.98 / 408.04 | 2 | 2 |
6 | 13 | 80.04 | 20 | 15.07 | 379 | 114 | 3.10 / 408.16 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.05 | 258 | 641 | 3.74 / 408.80 | 2 | 6 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 29 | 14.99 | 400 | 174 | 0.17 / 401.48 | 3 | 3 |
2 | 7 | 2011.52 | 30 | 14.88 | 2919 | 1303 | 1.48 / 402.79 | 2 | 2 |
3 | 13 | 1742.36 | 20 | 14.83 | 2588 | 768 | 2.24 / 403.56 | 2 | 2 |
4 | 13 | 994.56 | 20 | 14.93 | 1635 | 488 | 2.73 / 404.04 | 2 | 3 |
5 | 13 | 418.56 | 20 | 15.02 | 864 | 260 | 2.99 / 404.30 | 2 | 2 |
6 | 13 | 80.84 | 20 | 15.08 | 377 | 114 | 3.11 / 404.42 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.04 | 258 | 640 | 3.75 / 405.06 | 2 | 4 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.72 | 29 | 14.99 | 402 | 175 | 0.17 / 397.76 | 3 | 3 |
2 | 7 | 2004.80 | 30 | 14.91 | 2904 | 1299 | 1.47 / 399.06 | 2 | 2 |
3 | 13 | 1611.16 | 20 | 14.88 | 2419 | 720 | 2.19 / 399.78 | 2 | 2 |
4 | 13 | 1023.20 | 20 | 14.93 | 1670 | 499 | 2.69 / 400.28 | 2 | 3 |
5 | 13 | 447.80 | 20 | 15.02 | 905 | 272 | 2.96 / 400.55 | 2 | 2 |
6 | 13 | 78.72 | 20 | 15.08 | 378 | 114 | 3.08 / 400.67 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.05 | 259 | 643 | 3.72 / 401.31 | 2 | 8 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 29 | 14.98 | 404 | 176 | 0.18 / 394.06 | 3 | 3 |
2 | 7 | 2003.96 | 30 | 14.89 | 2897 | 1294 | 1.47 / 395.36 | 2 | 2 |
3 | 13 | 1602.48 | 20 | 14.87 | 2416 | 719 | 2.19 / 396.08 | 2 | 2 |
4 | 13 | 1021.44 | 20 | 14.93 | 1668 | 498 | 2.69 / 396.57 | 2 | 3 |
5 | 13 | 432.12 | 20 | 15.03 | 883 | 265 | 2.95 / 396.84 | 2 | 2 |
6 | 13 | 80.68 | 20 | 15.09 | 377 | 114 | 3.07 / 396.95 | 2 | 2 |
7 | 8 | -0.04 | 165 | 15.06 | 256 | 636 | 3.70 / 397.59 | 2 | 4 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.72 | 29 | 14.99 | 401 | 174 | 0.17 / 390.22 | 3 | 3 |
2 | 7 | 2003.36 | 30 | 14.89 | 2903 | 1297 | 1.47 / 391.52 | 2 | 2 |
3 | 13 | 1603.76 | 20 | 14.88 | 2417 | 719 | 2.19 / 392.24 | 2 | 3 |
4 | 13 | 1032.20 | 20 | 14.94 | 1688 | 504 | 2.69 / 392.74 | 2 | 3 |
5 | 13 | 452.96 | 20 | 15.03 | 913 | 274 | 2.97 / 393.02 | 2 | 2 |
6 | 13 | 81.12 | 20 | 15.08 | 380 | 115 | 3.08 / 393.13 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.05 | 257 | 638 | 3.72 / 393.77 | 2 | 3 |
8 | 14 | 0.08 | 30 | 15.02 | 258 | 116 | 3.84 / 393.89 | 2 | 5 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 29 | 14.99 | 396 | 172 | 0.17 / 386.53 | 3 | 3 |
2 | 7 | 2008.52 | 30 | 14.86 | 2903 | 1294 | 1.47 / 387.82 | 2 | 3 |
3 | 13 | 1598.16 | 20 | 14.85 | 2408 | 715 | 2.18 / 388.53 | 2 | 2 |
4 | 13 | 1020.96 | 20 | 14.90 | 1674 | 499 | 2.68 / 389.03 | 2 | 3 |
5 | 13 | 429.24 | 20 | 15.03 | 879 | 264 | 2.94 / 389.30 | 2 | 3 |
6 | 13 | 87.84 | 20 | 15.08 | 386 | 116 | 3.06 / 389.41 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.05 | 256 | 636 | 3.70 / 390.05 | 2 | 4 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 29 | 14.99 | 403 | 175 | 0.18 / 382.83 | 3 | 3 |
2 | 7 | 2003.48 | 30 | 14.89 | 2891 | 1291 | 1.47 / 384.13 | 2 | 3 |
3 | 13 | 1606.52 | 20 | 14.88 | 2419 | 720 | 2.19 / 384.85 | 2 | 3 |
4 | 13 | 1023.24 | 20 | 14.94 | 1674 | 500 | 2.69 / 385.35 | 2 | 3 |
5 | 13 | 420.20 | 20 | 15.03 | 870 | 262 | 2.95 / 385.61 | 2 | 2 |
6 | 13 | 92.56 | 20 | 15.08 | 392 | 118 | 3.07 / 385.73 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.04 | 253 | 628 | 3.69 / 386.35 | 2 | 3 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 29 | 15.00 | 409 | 178 | 0.18 / 379.03 | 3 | 3 |
2 | 7 | 2003.32 | 30 | 14.88 | 2905 | 1297 | 1.47 / 380.33 | 2 | 3 |
3 | 13 | 1602.00 | 20 | 14.86 | 2402 | 714 | 2.19 / 381.04 | 2 | 3 |
4 | 13 | 1036.20 | 20 | 14.91 | 1688 | 503 | 2.69 / 381.55 | 2 | 3 |
5 | 13 | 446.08 | 20 | 15.00 | 905 | 271 | 2.96 / 381.82 | 2 | 3 |
6 | 13 | 88.16 | 20 | 15.06 | 388 | 117 | 3.08 / 381.93 | 2 | 2 |
7 | 13 | 23.76 | 20 | 15.06 | 296 | 89 | 3.17 / 382.02 | 2 | 3 |
8 | 8 | 0.08 | 165 | 15.03 | 256 | 635 | 3.80 / 382.66 | 2 | 7 |
Average= | 3.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 29 | 14.99 | 400 | 174 | 0.17 / 375.20 | 3 | 3 |
2 | 7 | 2002.64 | 30 | 14.90 | 2907 | 1299 | 1.47 / 376.50 | 2 | 3 |
3 | 13 | 1723.32 | 20 | 14.86 | 2567 | 763 | 2.24 / 377.26 | 2 | 3 |
4 | 13 | 1001.96 | 20 | 14.94 | 1651 | 493 | 2.73 / 377.76 | 2 | 3 |
5 | 13 | 425.72 | 20 | 15.04 | 875 | 263 | 2.99 / 378.02 | 2 | 2 |
6 | 13 | 86.92 | 20 | 15.08 | 385 | 116 | 3.11 / 378.13 | 2 | 2 |
7 | 13 | 25.04 | 20 | 15.08 | 296 | 89 | 3.20 / 378.22 | 2 | 2 |
8 | 8 | 0.00 | 165 | 15.04 | 254 | 630 | 3.83 / 378.85 | 2 | 4 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.20 | 29 | 14.99 | 402 | 175 | 0.17 / 371.39 | 3 | 3 |
2 | 7 | 2007.60 | 30 | 14.89 | 2904 | 1297 | 1.47 / 372.69 | 2 | 3 |
3 | 13 | 1603.00 | 20 | 14.87 | 2424 | 721 | 2.19 / 373.41 | 2 | 2 |
4 | 13 | 1033.72 | 20 | 14.94 | 1692 | 506 | 2.70 / 373.91 | 2 | 3 |
5 | 13 | 447.12 | 20 | 15.03 | 902 | 271 | 2.97 / 374.18 | 2 | 2 |
6 | 13 | 90.84 | 20 | 15.08 | 394 | 119 | 3.09 / 374.30 | 2 | 2 |
7 | 13 | 24.60 | 20 | 15.09 | 296 | 89 | 3.18 / 374.39 | 2 | 2 |
8 | 8 | 0.00 | 165 | 15.05 | 255 | 633 | 3.81 / 375.03 | 2 | 4 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.84 | 29 | 14.98 | 398 | 173 | 0.17 / 367.50 | 3 | 3 |
2 | 7 | 2006.48 | 30 | 14.87 | 2897 | 1292 | 1.47 / 368.79 | 2 | 3 |
3 | 13 | 1723.04 | 20 | 14.84 | 2557 | 759 | 2.22 / 369.55 | 2 | 3 |
4 | 13 | 998.48 | 20 | 14.92 | 1639 | 489 | 2.71 / 370.04 | 2 | 3 |
5 | 13 | 550.96 | 20 | 14.98 | 1048 | 314 | 3.03 / 370.35 | 2 | 3 |
6 | 13 | 106.72 | 20 | 15.06 | 422 | 127 | 3.15 / 370.48 | 2 | 2 |
7 | 13 | 30.36 | 20 | 15.05 | 310 | 93 | 3.25 / 370.57 | 2 | 2 |
8 | 8 | -0.12 | 165 | 15.03 | 260 | 645 | 3.89 / 371.21 | 2 | 3 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.20 | 29 | 14.99 | 412 | 179 | 0.18 / 363.58 | 3 | 3 |
2 | 7 | 2002.68 | 30 | 14.89 | 2889 | 1291 | 1.47 / 364.87 | 2 | 2 |
3 | 13 | 1596.52 | 20 | 14.88 | 2409 | 717 | 2.19 / 365.59 | 2 | 3 |
4 | 13 | 1023.56 | 20 | 14.94 | 1675 | 500 | 2.69 / 366.09 | 2 | 3 |
5 | 13 | 440.28 | 20 | 15.03 | 897 | 270 | 2.96 / 366.36 | 2 | 2 |
6 | 13 | 92.96 | 20 | 15.08 | 396 | 119 | 3.08 / 366.48 | 2 | 2 |
7 | 13 | 51.84 | 20 | 15.09 | 334 | 101 | 3.18 / 366.58 | 2 | 2 |
8 | 8 | 0.24 | 165 | 15.05 | 253 | 628 | 3.81 / 367.21 | 2 | 6 |
9 | 14 | 0.24 | 30 | 15.02 | 252 | 114 | 3.92 / 367.32 | 3 | 10 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.08 | 29 | 15.00 | 404 | 176 | 0.18 / 359.76 | 3 | 3 |
2 | 7 | 2004.84 | 30 | 14.87 | 2904 | 1295 | 1.47 / 361.06 | 2 | 3 |
3 | 13 | 1615.44 | 20 | 14.86 | 2428 | 722 | 2.19 / 361.78 | 2 | 2 |
4 | 13 | 1033.92 | 20 | 14.91 | 1683 | 502 | 2.69 / 362.28 | 2 | 3 |
5 | 13 | 447.12 | 20 | 15.02 | 904 | 272 | 2.97 / 362.55 | 2 | 3 |
6 | 13 | 107.32 | 20 | 15.06 | 413 | 124 | 3.09 / 362.68 | 2 | 2 |
7 | 13 | 61.16 | 20 | 15.06 | 343 | 103 | 3.19 / 362.78 | 2 | 2 |
8 | 8 | 0.12 | 165 | 15.03 | 252 | 625 | 3.82 / 363.40 | 2 | 4 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.16 | 29 | 15.00 | 404 | 176 | 0.18 / 355.89 | 3 | 3 |
2 | 7 | 2003.88 | 31 | 14.89 | 2899 | 1338 | 1.51 / 357.23 | 2 | 3 |
3 | 13 | 1602.80 | 20 | 14.88 | 2415 | 719 | 2.23 / 357.95 | 2 | 3 |
4 | 13 | 1023.36 | 20 | 14.93 | 1675 | 500 | 2.73 / 358.45 | 2 | 3 |
5 | 13 | 431.28 | 20 | 15.02 | 881 | 265 | 3.00 / 358.72 | 2 | 2 |
6 | 13 | 130.00 | 20 | 15.07 | 453 | 137 | 3.13 / 358.85 | 2 | 2 |
7 | 13 | 38.32 | 20 | 15.08 | 316 | 95 | 3.23 / 358.95 | 2 | 2 |
8 | 8 | 0.16 | 165 | 15.04 | 257 | 638 | 3.87 / 359.58 | 2 | 6 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 29 | 15.00 | 400 | 174 | 0.17 / 351.96 | 3 | 3 |
2 | 7 | 2006.56 | 30 | 14.89 | 2896 | 1294 | 1.47 / 353.26 | 2 | 2 |
3 | 13 | 1611.68 | 20 | 14.87 | 2422 | 720 | 2.19 / 353.98 | 2 | 3 |
4 | 13 | 1029.48 | 20 | 14.93 | 1679 | 501 | 2.69 / 354.48 | 2 | 2 |
5 | 13 | 439.80 | 20 | 15.03 | 899 | 270 | 2.96 / 354.75 | 2 | 3 |
6 | 13 | 80.40 | 20 | 15.08 | 380 | 115 | 3.07 / 354.86 | 2 | 2 |
7 | 13 | 44.28 | 20 | 15.08 | 330 | 100 | 3.17 / 354.96 | 2 | 2 |
8 | 8 | 0.20 | 165 | 15.05 | 258 | 641 | 3.81 / 355.60 | 2 | 5 |
9 | 14 | 0.20 | 30 | 15.02 | 256 | 115 | 3.93 / 355.72 | 3 | 8 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.64 | 29 | 15.02 | 399 | 174 | 0.17 / 348.26 | 3 | 3 |
2 | 7 | 2004.32 | 30 | 14.90 | 2898 | 1295 | 1.47 / 349.55 | 2 | 2 |
3 | 13 | 1599.80 | 20 | 14.88 | 2404 | 715 | 2.18 / 350.27 | 2 | 3 |
4 | 13 | 1016.28 | 20 | 14.94 | 1668 | 498 | 2.68 / 350.76 | 2 | 3 |
5 | 13 | 428.08 | 20 | 15.04 | 880 | 265 | 2.95 / 351.03 | 2 | 2 |
6 | 13 | 68.68 | 20 | 15.11 | 367 | 111 | 3.06 / 351.14 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.04 | 261 | 648 | 3.71 / 351.79 | 2 | 4 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 29 | 14.99 | 403 | 175 | 0.18 / 344.44 | 3 | 3 |
2 | 7 | 2004.32 | 30 | 14.90 | 2895 | 1294 | 1.47 / 345.74 | 2 | 2 |
3 | 13 | 1608.88 | 20 | 14.88 | 2413 | 718 | 2.19 / 346.46 | 2 | 2 |
4 | 13 | 1042.04 | 20 | 14.93 | 1697 | 507 | 2.69 / 346.96 | 2 | 3 |
5 | 13 | 435.56 | 20 | 15.03 | 885 | 266 | 2.96 / 347.23 | 2 | 2 |
6 | 13 | 72.24 | 20 | 15.10 | 377 | 114 | 3.07 / 347.34 | 2 | 2 |
7 | 13 | 16.84 | 20 | 15.09 | 295 | 89 | 3.16 / 347.43 | 2 | 2 |
8 | 8 | 0.08 | 165 | 15.06 | 262 | 651 | 3.81 / 348.08 | 2 | 7 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 29 | 14.99 | 414 | 180 | 0.18 / 340.71 | 2 | 3 |
2 | 7 | 2009.84 | 30 | 14.90 | 2910 | 1301 | 1.48 / 342.01 | 2 | 2 |
3 | 13 | 1615.12 | 20 | 14.87 | 2424 | 721 | 2.20 / 342.73 | 2 | 2 |
4 | 13 | 1033.24 | 20 | 14.92 | 1684 | 503 | 2.70 / 343.24 | 2 | 2 |
5 | 13 | 434.44 | 20 | 15.04 | 886 | 267 | 2.97 / 343.50 | 2 | 2 |
6 | 13 | 64.96 | 20 | 15.09 | 363 | 110 | 3.08 / 343.61 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.07 | 264 | 656 | 3.74 / 344.27 | 2 | 5 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.36 | 29 | 15.00 | 399 | 174 | 0.17 / 336.52 | 3 | 3 |
2 | 7 | 2002.88 | 30 | 14.92 | 2898 | 1297 | 1.47 / 337.82 | 2 | 2 |
3 | 13 | 1601.20 | 20 | 14.90 | 2407 | 717 | 2.19 / 338.54 | 2 | 2 |
4 | 13 | 1018.32 | 20 | 14.95 | 1664 | 498 | 2.69 / 339.03 | 2 | 2 |
5 | 13 | 509.20 | 20 | 15.04 | 987 | 297 | 2.98 / 339.33 | 2 | 2 |
6 | 13 | 504.88 | 20 | 14.99 | 972 | 291 | 3.27 / 339.62 | 2 | 3 |
7 | 13 | 426.56 | 20 | 15.00 | 859 | 258 | 3.53 / 339.88 | 2 | 3 |
8 | 8 | 0.00 | 165 | 15.04 | 262 | 650 | 4.18 / 340.53 | 2 | 8 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.16 | 29 | 15.01 | 395 | 172 | 0.17 / 332.67 | 3 | 3 |
2 | 7 | 2008.04 | 31 | 14.92 | 2912 | 1347 | 1.52 / 334.02 | 2 | 3 |
3 | 13 | 1607.28 | 20 | 14.89 | 2420 | 721 | 2.24 / 334.74 | 2 | 2 |
4 | 13 | 1035.08 | 20 | 14.95 | 1694 | 507 | 2.75 / 335.24 | 2 | 3 |
5 | 13 | 432.92 | 20 | 15.06 | 880 | 265 | 3.01 / 335.51 | 2 | 2 |
6 | 13 | 76.28 | 20 | 15.12 | 372 | 112 | 3.12 / 335.62 | 2 | 2 |
7 | 13 | 18.96 | 20 | 15.11 | 289 | 87 | 3.21 / 335.71 | 2 | 2 |
8 | 8 | 0.04 | 165 | 15.08 | 258 | 642 | 3.85 / 336.35 | 2 | 5 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 29 | 15.02 | 409 | 178 | 0.18 / 328.84 | 3 | 3 |
2 | 7 | 2003.28 | 30 | 14.92 | 2901 | 1298 | 1.48 / 330.14 | 2 | 2 |
3 | 13 | 1726.68 | 20 | 14.88 | 2565 | 763 | 2.24 / 330.90 | 2 | 2 |
4 | 13 | 1116.40 | 20 | 14.93 | 1790 | 534 | 2.77 / 331.44 | 2 | 2 |
5 | 13 | 500.52 | 20 | 15.03 | 972 | 292 | 3.07 / 331.73 | 2 | 3 |
6 | 13 | 89.72 | 20 | 15.10 | 395 | 119 | 3.19 / 331.85 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.07 | 260 | 647 | 3.83 / 332.50 | 2 | 4 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.20 | 29 | 15.03 | 400 | 174 | 0.17 / 325.10 | 2 | 3 |
2 | 7 | 2002.12 | 30 | 14.92 | 2893 | 1295 | 1.47 / 326.39 | 2 | 3 |
3 | 13 | 1485.08 | 20 | 14.92 | 2261 | 675 | 2.14 / 327.07 | 2 | 3 |
4 | 13 | 1070.36 | 20 | 14.94 | 1734 | 518 | 2.66 / 327.58 | 2 | 2 |
5 | 13 | 346.44 | 20 | 15.08 | 760 | 229 | 2.89 / 327.81 | 2 | 2 |
6 | 13 | 98.64 | 20 | 15.11 | 404 | 122 | 3.01 / 327.93 | 2 | 2 |
7 | 13 | 22.32 | 20 | 15.12 | 298 | 90 | 3.10 / 328.02 | 2 | 2 |
8 | 8 | 0.08 | 165 | 15.08 | 257 | 639 | 3.74 / 328.66 | 2 | 10 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.56 | 29 | 15.04 | 396 | 173 | 0.17 / 321.38 | 3 | 3 |
2 | 7 | 2009.72 | 30 | 14.91 | 2914 | 1303 | 1.48 / 322.68 | 2 | 2 |
3 | 13 | 1603.36 | 20 | 14.89 | 2416 | 719 | 2.20 / 323.40 | 2 | 3 |
4 | 13 | 1017.08 | 20 | 14.97 | 1665 | 499 | 2.69 / 323.90 | 2 | 2 |
5 | 13 | 434.32 | 20 | 15.04 | 881 | 265 | 2.96 / 324.17 | 2 | 2 |
6 | 13 | 72.56 | 20 | 15.09 | 369 | 111 | 3.07 / 324.28 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.06 | 259 | 644 | 3.71 / 324.92 | 2 | 5 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.60 | 29 | 15.02 | 399 | 174 | 0.17 / 317.64 | 2 | 3 |
2 | 7 | 2005.48 | 30 | 14.92 | 2909 | 1302 | 1.48 / 318.95 | 2 | 2 |
3 | 13 | 1618.36 | 20 | 14.89 | 2428 | 723 | 2.20 / 319.67 | 2 | 3 |
4 | 13 | 1041.08 | 20 | 14.95 | 1699 | 508 | 2.71 / 320.18 | 2 | 3 |
5 | 13 | 437.80 | 20 | 15.05 | 890 | 268 | 2.97 / 320.44 | 2 | 2 |
6 | 13 | 83.24 | 20 | 15.11 | 384 | 116 | 3.09 / 320.56 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.06 | 260 | 646 | 3.74 / 321.21 | 2 | 3 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 29 | 15.04 | 405 | 177 | 0.18 / 313.94 | 2 | 3 |
2 | 7 | 2003.76 | 30 | 14.92 | 2899 | 1298 | 1.47 / 315.23 | 2 | 2 |
3 | 13 | 1602.80 | 20 | 14.90 | 2422 | 722 | 2.20 / 315.95 | 2 | 2 |
4 | 13 | 1019.48 | 20 | 14.96 | 1671 | 500 | 2.70 / 316.45 | 2 | 3 |
5 | 13 | 426.68 | 20 | 15.07 | 879 | 265 | 2.96 / 316.72 | 2 | 2 |
6 | 13 | 78.12 | 20 | 15.12 | 376 | 114 | 3.07 / 316.83 | 2 | 2 |
7 | 8 | -0.04 | 165 | 15.08 | 256 | 637 | 3.71 / 317.47 | 2 | 4 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 29 | 15.04 | 400 | 174 | 0.17 / 310.29 | 2 | 3 |
2 | 7 | 2003.84 | 30 | 14.90 | 2896 | 1295 | 1.47 / 311.59 | 2 | 2 |
3 | 13 | 1477.52 | 20 | 14.89 | 2249 | 670 | 2.14 / 312.26 | 2 | 3 |
4 | 13 | 1059.92 | 20 | 14.93 | 1717 | 513 | 2.65 / 312.77 | 2 | 2 |
5 | 13 | 338.44 | 20 | 15.06 | 743 | 224 | 2.88 / 313.00 | 2 | 2 |
6 | 13 | 98.40 | 20 | 15.10 | 402 | 121 | 3.00 / 313.12 | 2 | 2 |
7 | 8 | 0.20 | 165 | 15.07 | 258 | 642 | 3.64 / 313.76 | 2 | 4 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 29 | 15.05 | 402 | 175 | 0.18 / 306.45 | 3 | 3 |
2 | 7 | 2004.00 | 31 | 14.93 | 2898 | 1341 | 1.52 / 307.79 | 2 | 2 |
3 | 13 | 1602.12 | 20 | 14.91 | 2414 | 720 | 2.24 / 308.51 | 2 | 2 |
4 | 13 | 1018.88 | 20 | 14.97 | 1668 | 499 | 2.74 / 309.01 | 2 | 2 |
5 | 13 | 437.72 | 20 | 15.06 | 888 | 267 | 3.00 / 309.27 | 2 | 2 |
6 | 13 | 81.12 | 20 | 15.15 | 377 | 114 | 3.12 / 309.39 | 2 | 2 |
7 | 13 | 20.32 | 20 | 15.14 | 293 | 89 | 3.21 / 309.48 | 2 | 2 |
8 | 8 | 0.08 | 165 | 15.10 | 258 | 643 | 3.85 / 310.12 | 2 | 5 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 29 | 15.03 | 400 | 174 | 0.17 / 302.73 | 2 | 3 |
2 | 7 | 2008.20 | 31 | 14.92 | 2907 | 1345 | 1.52 / 304.08 | 2 | 2 |
3 | 13 | 1609.68 | 20 | 14.92 | 2429 | 725 | 2.24 / 304.80 | 2 | 3 |
4 | 13 | 1020.12 | 20 | 14.97 | 1661 | 497 | 2.74 / 305.30 | 2 | 3 |
5 | 13 | 323.24 | 20 | 15.11 | 726 | 219 | 2.96 / 305.52 | 2 | 2 |
6 | 13 | 100.68 | 20 | 15.13 | 402 | 122 | 3.08 / 305.64 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.10 | 253 | 630 | 3.71 / 306.27 | 2 | 3 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 121.32 | 29 | 15.05 | 424 | 185 | 0.19 / 298.88 | 3 | 3 |
2 | 7 | 2005.48 | 30 | 14.90 | 2897 | 1295 | 1.48 / 300.17 | 2 | 2 |
3 | 13 | 1489.96 | 20 | 14.91 | 2269 | 677 | 2.16 / 300.85 | 2 | 2 |
4 | 13 | 1057.28 | 20 | 14.93 | 1717 | 513 | 2.67 / 301.36 | 2 | 3 |
5 | 13 | 587.00 | 20 | 15.03 | 1098 | 330 | 3.00 / 301.69 | 2 | 3 |
6 | 13 | 120.76 | 20 | 15.10 | 442 | 133 | 3.13 / 301.82 | 2 | 2 |
7 | 13 | 29.24 | 20 | 15.11 | 307 | 93 | 3.23 / 301.92 | 2 | 2 |
8 | 8 | 0.08 | 165 | 15.09 | 258 | 642 | 3.87 / 302.56 | 2 | 8 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.76 | 29 | 15.06 | 400 | 175 | 0.17 / 295.22 | 3 | 3 |
2 | 7 | 2005.36 | 30 | 14.91 | 2895 | 1295 | 1.47 / 296.52 | 2 | 2 |
3 | 13 | 1495.96 | 20 | 14.91 | 2278 | 679 | 2.15 / 297.20 | 2 | 2 |
4 | 13 | 954.12 | 20 | 14.96 | 1581 | 473 | 2.62 / 297.67 | 2 | 2 |
5 | 13 | 386.96 | 20 | 15.08 | 814 | 246 | 2.87 / 297.91 | 2 | 2 |
6 | 13 | 111.20 | 20 | 15.11 | 426 | 129 | 3.00 / 298.04 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.10 | 260 | 648 | 3.64 / 298.69 | 2 | 3 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.92 | 29 | 15.07 | 407 | 178 | 0.18 / 291.49 | 3 | 3 |
2 | 7 | 2008.24 | 30 | 14.94 | 2900 | 1300 | 1.48 / 292.79 | 2 | 2 |
3 | 13 | 1596.48 | 20 | 14.93 | 2410 | 720 | 2.20 / 293.51 | 2 | 2 |
4 | 13 | 1021.24 | 20 | 14.98 | 1669 | 500 | 2.70 / 294.01 | 2 | 3 |
5 | 13 | 431.44 | 20 | 15.09 | 882 | 266 | 2.96 / 294.28 | 2 | 2 |
6 | 13 | 75.96 | 20 | 15.14 | 375 | 114 | 3.08 / 294.39 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.12 | 262 | 654 | 3.73 / 295.05 | 2 | 4 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.04 | 29 | 15.06 | 396 | 173 | 0.17 / 287.66 | 3 | 3 |
2 | 7 | 2004.68 | 30 | 14.94 | 2903 | 1301 | 1.47 / 288.96 | 2 | 2 |
3 | 13 | 1595.96 | 20 | 14.91 | 2397 | 715 | 2.19 / 289.67 | 2 | 2 |
4 | 13 | 1016.04 | 20 | 14.98 | 1660 | 497 | 2.69 / 290.17 | 2 | 3 |
5 | 13 | 421.80 | 20 | 15.08 | 868 | 262 | 2.95 / 290.43 | 2 | 2 |
6 | 13 | 82.68 | 20 | 15.14 | 383 | 116 | 3.06 / 290.55 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.12 | 261 | 651 | 3.72 / 291.20 | 2 | 4 |
8 | 14 | 0.12 | 30 | 15.09 | 261 | 118 | 3.83 / 291.32 | 2 | 3 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 29 | 15.08 | 413 | 181 | 0.18 / 283.85 | 3 | 3 |
2 | 7 | 2003.76 | 30 | 14.95 | 2905 | 1303 | 1.48 / 285.16 | 2 | 2 |
3 | 13 | 1612.00 | 20 | 14.93 | 2430 | 726 | 2.21 / 285.88 | 2 | 3 |
4 | 13 | 1021.96 | 20 | 14.99 | 1671 | 501 | 2.71 / 286.38 | 2 | 3 |
5 | 13 | 310.72 | 20 | 15.13 | 713 | 216 | 2.93 / 286.60 | 2 | 2 |
6 | 13 | 91.24 | 20 | 15.16 | 394 | 119 | 3.05 / 286.72 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.14 | 259 | 647 | 3.69 / 287.37 | 2 | 3 |
8 | 14 | 0.08 | 30 | 15.09 | 259 | 117 | 3.81 / 287.48 | 3 | 5 |
Average= | 3.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 29 | 15.09 | 394 | 172 | 0.17 / 280.13 | 2 | 3 |
2 | 7 | 2009.92 | 30 | 14.93 | 2898 | 1298 | 1.47 / 281.43 | 2 | 2 |
3 | 13 | 1592.24 | 20 | 14.91 | 2398 | 715 | 2.19 / 282.15 | 2 | 2 |
4 | 13 | 1015.72 | 20 | 14.99 | 1663 | 499 | 2.68 / 282.64 | 2 | 2 |
5 | 13 | 421.20 | 20 | 15.10 | 867 | 262 | 2.95 / 282.91 | 2 | 3 |
6 | 13 | 75.32 | 20 | 15.15 | 375 | 114 | 3.06 / 283.02 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.13 | 262 | 654 | 3.71 / 283.67 | 2 | 4 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.88 | 29 | 15.09 | 405 | 177 | 0.18 / 276.27 | 3 | 3 |
2 | 7 | 2006.12 | 30 | 14.93 | 2899 | 1298 | 1.48 / 277.57 | 2 | 2 |
3 | 13 | 1734.36 | 20 | 14.90 | 2576 | 768 | 2.24 / 278.34 | 2 | 3 |
4 | 13 | 980.48 | 20 | 15.00 | 1619 | 486 | 2.73 / 278.82 | 2 | 2 |
5 | 13 | 399.96 | 20 | 15.10 | 840 | 254 | 2.98 / 279.08 | 2 | 2 |
6 | 13 | 63.44 | 20 | 15.16 | 361 | 109 | 3.09 / 279.19 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.13 | 262 | 654 | 3.75 / 279.84 | 2 | 4 |
8 | 14 | 0.04 | 30 | 15.11 | 260 | 118 | 3.86 / 279.96 | 2 | 4 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 29 | 15.09 | 403 | 176 | 0.18 / 272.43 | 3 | 3 |
2 | 7 | 2002.16 | 30 | 14.95 | 2900 | 1301 | 1.48 / 273.73 | 2 | 3 |
3 | 13 | 1589.72 | 20 | 14.94 | 2396 | 716 | 2.19 / 274.44 | 2 | 2 |
4 | 13 | 1021.60 | 20 | 15.01 | 1670 | 501 | 2.69 / 274.94 | 2 | 2 |
5 | 13 | 435.44 | 20 | 15.12 | 890 | 269 | 2.96 / 275.21 | 2 | 2 |
6 | 13 | 76.24 | 20 | 15.18 | 373 | 113 | 3.08 / 275.33 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.15 | 261 | 652 | 3.73 / 275.98 | 2 | 7 |
8 | 14 | 0.16 | 30 | 15.11 | 259 | 117 | 3.85 / 276.10 | 2 | 6 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 29 | 15.10 | 398 | 174 | 0.17 / 268.56 | 3 | 3 |
2 | 7 | 2003.60 | 30 | 14.94 | 2905 | 1302 | 1.48 / 269.86 | 2 | 3 |
3 | 13 | 1607.44 | 20 | 14.93 | 2414 | 721 | 2.20 / 270.58 | 2 | 2 |
4 | 13 | 1028.56 | 20 | 14.99 | 1678 | 503 | 2.70 / 271.08 | 2 | 3 |
5 | 13 | 434.52 | 20 | 15.11 | 890 | 269 | 2.97 / 271.35 | 2 | 2 |
6 | 13 | 70.96 | 20 | 15.17 | 374 | 113 | 3.08 / 271.46 | 2 | 2 |
7 | 8 | 0.20 | 165 | 15.14 | 266 | 664 | 3.75 / 272.13 | 2 | 5 |
8 | 14 | 0.20 | 30 | 15.12 | 266 | 121 | 3.87 / 272.25 | 2 | 4 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.08 | 29 | 15.11 | 407 | 178 | 0.18 / 264.79 | 3 | 3 |
2 | 7 | 2004.48 | 30 | 14.93 | 2891 | 1295 | 1.47 / 266.09 | 2 | 2 |
3 | 13 | 1612.32 | 20 | 14.92 | 2425 | 724 | 2.20 / 266.81 | 2 | 2 |
4 | 13 | 1158.04 | 20 | 14.96 | 1846 | 552 | 2.75 / 267.37 | 2 | 3 |
5 | 13 | 400.28 | 20 | 15.11 | 843 | 255 | 3.00 / 267.62 | 2 | 2 |
6 | 13 | 65.24 | 20 | 15.17 | 360 | 109 | 3.11 / 267.73 | 2 | 2 |
7 | 8 | 0.24 | 165 | 15.14 | 261 | 652 | 3.77 / 268.38 | 2 | 8 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 29 | 15.10 | 399 | 175 | 0.17 / 261.02 | 2 | 3 |
2 | 7 | 2004.88 | 30 | 14.96 | 2905 | 1304 | 1.48 / 262.32 | 2 | 2 |
3 | 13 | 1604.00 | 20 | 14.95 | 2416 | 722 | 2.20 / 263.04 | 2 | 2 |
4 | 13 | 1148.92 | 20 | 14.99 | 1840 | 552 | 2.75 / 263.60 | 2 | 3 |
5 | 13 | 386.04 | 20 | 15.15 | 827 | 251 | 3.00 / 263.85 | 2 | 2 |
6 | 13 | 58.92 | 20 | 15.21 | 357 | 109 | 3.11 / 263.96 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.17 | 264 | 661 | 3.77 / 264.62 | 2 | 3 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.88 | 29 | 15.11 | 398 | 174 | 0.17 / 257.18 | 3 | 3 |
2 | 7 | 2007.16 | 30 | 14.97 | 2910 | 1307 | 1.48 / 258.49 | 2 | 2 |
3 | 13 | 1728.40 | 20 | 14.93 | 2571 | 768 | 2.25 / 259.26 | 2 | 2 |
4 | 13 | 993.28 | 20 | 15.02 | 1639 | 492 | 2.74 / 259.75 | 2 | 2 |
5 | 13 | 540.04 | 20 | 15.11 | 1038 | 314 | 3.06 / 260.06 | 2 | 2 |
6 | 13 | 63.28 | 20 | 15.20 | 366 | 111 | 3.17 / 260.18 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.17 | 267 | 668 | 3.83 / 260.84 | 2 | 5 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 29 | 15.12 | 418 | 183 | 0.18 / 253.40 | 2 | 3 |
2 | 7 | 2010.04 | 31 | 14.95 | 2913 | 1350 | 1.53 / 254.75 | 2 | 2 |
3 | 13 | 1601.80 | 20 | 14.94 | 2418 | 722 | 2.26 / 255.47 | 2 | 3 |
4 | 13 | 1010.52 | 20 | 15.02 | 1665 | 500 | 2.76 / 255.97 | 2 | 2 |
5 | 13 | 415.48 | 20 | 15.14 | 863 | 261 | 3.02 / 256.23 | 2 | 2 |
6 | 13 | 64.32 | 20 | 15.20 | 367 | 112 | 3.13 / 256.34 | 2 | 2 |
7 | 8 | 0.00 | 165 | 15.16 | 266 | 665 | 3.79 / 257.01 | 2 | 6 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 29 | 15.11 | 403 | 177 | 0.18 / 249.66 | 3 | 3 |
2 | 7 | 2002.28 | 30 | 14.93 | 2897 | 1298 | 1.47 / 250.96 | 2 | 3 |
3 | 13 | 1592.04 | 20 | 14.93 | 2397 | 716 | 2.19 / 251.67 | 2 | 2 |
4 | 13 | 1005.36 | 20 | 15.00 | 1649 | 495 | 2.68 / 252.17 | 2 | 3 |
5 | 13 | 392.32 | 20 | 15.14 | 835 | 253 | 2.94 / 252.42 | 2 | 2 |
6 | 13 | 109.88 | 20 | 15.18 | 433 | 131 | 3.07 / 252.55 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.15 | 265 | 662 | 3.73 / 253.21 | 2 | 5 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 29 | 15.12 | 409 | 179 | 0.18 / 245.69 | 3 | 3 |
2 | 7 | 2003.68 | 30 | 14.95 | 2901 | 1301 | 1.48 / 246.99 | 2 | 2 |
3 | 13 | 1600.68 | 20 | 14.93 | 2408 | 719 | 2.20 / 247.71 | 2 | 2 |
4 | 13 | 1007.52 | 20 | 15.01 | 1655 | 497 | 2.70 / 248.20 | 2 | 3 |
5 | 13 | 412.68 | 20 | 15.14 | 860 | 260 | 2.96 / 248.46 | 2 | 2 |
6 | 13 | 115.76 | 20 | 15.20 | 442 | 134 | 3.09 / 248.60 | 2 | 2 |
7 | 13 | 61.76 | 20 | 15.19 | 362 | 110 | 3.20 / 248.71 | 2 | 2 |
8 | 8 | 0.20 | 165 | 15.16 | 262 | 655 | 3.86 / 249.36 | 2 | 4 |
9 | 14 | 0.20 | 30 | 15.13 | 262 | 119 | 3.98 / 249.48 | 3 | 11 |
Average= | 3.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 29 | 15.12 | 405 | 178 | 0.18 / 241.87 | 3 | 3 |
2 | 7 | 2004.04 | 30 | 14.97 | 2901 | 1303 | 1.48 / 243.18 | 2 | 3 |
3 | 13 | 1476.96 | 20 | 14.98 | 2264 | 678 | 2.16 / 243.85 | 2 | 2 |
4 | 13 | 1039.24 | 20 | 15.03 | 1697 | 510 | 2.67 / 244.36 | 2 | 2 |
5 | 13 | 426.04 | 20 | 15.15 | 882 | 267 | 2.94 / 244.63 | 2 | 3 |
6 | 13 | 66.16 | 20 | 15.22 | 369 | 112 | 3.05 / 244.74 | 2 | 2 |
7 | 13 | 39.68 | 20 | 15.22 | 330 | 100 | 3.15 / 244.84 | 2 | 2 |
8 | 8 | 0.08 | 165 | 15.18 | 265 | 664 | 3.81 / 245.51 | 2 | 6 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 29 | 15.13 | 402 | 176 | 0.18 / 238.16 | 3 | 3 |
2 | 7 | 2002.48 | 30 | 14.95 | 2903 | 1302 | 1.48 / 239.46 | 2 | 3 |
3 | 13 | 1473.12 | 20 | 14.96 | 2248 | 673 | 2.15 / 240.13 | 2 | 2 |
4 | 13 | 922.56 | 20 | 15.05 | 1550 | 467 | 2.62 / 240.60 | 2 | 2 |
5 | 13 | 347.60 | 20 | 15.16 | 771 | 234 | 2.85 / 240.83 | 2 | 2 |
6 | 13 | 92.40 | 20 | 15.20 | 400 | 122 | 2.97 / 240.95 | 2 | 2 |
7 | 13 | 21.16 | 20 | 15.20 | 299 | 91 | 3.06 / 241.04 | 2 | 2 |
8 | 8 | 0.00 | 165 | 15.16 | 261 | 653 | 3.72 / 241.70 | 2 | 5 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 29 | 15.14 | 397 | 174 | 0.17 / 234.32 | 3 | 3 |
2 | 7 | 2010.24 | 30 | 14.98 | 2919 | 1312 | 1.49 / 235.64 | 2 | 2 |
3 | 13 | 1598.32 | 20 | 14.96 | 2412 | 722 | 2.21 / 236.36 | 2 | 2 |
4 | 13 | 1008.88 | 20 | 15.04 | 1661 | 500 | 2.71 / 236.86 | 2 | 3 |
5 | 13 | 415.48 | 20 | 15.17 | 867 | 263 | 2.97 / 237.12 | 2 | 2 |
6 | 13 | 75.36 | 20 | 15.22 | 374 | 114 | 3.08 / 237.23 | 2 | 2 |
7 | 13 | 41.16 | 20 | 15.22 | 325 | 99 | 3.18 / 237.33 | 2 | 2 |
8 | 8 | 0.04 | 165 | 15.19 | 258 | 647 | 3.83 / 237.98 | 2 | 6 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 29 | 15.13 | 401 | 176 | 0.18 / 230.51 | 3 | 3 |
2 | 7 | 2006.56 | 30 | 14.98 | 2903 | 1305 | 1.48 / 231.82 | 2 | 2 |
3 | 13 | 1594.72 | 20 | 14.96 | 2410 | 721 | 2.20 / 232.54 | 2 | 3 |
4 | 13 | 1015.48 | 20 | 15.02 | 1661 | 499 | 2.70 / 233.04 | 2 | 2 |
5 | 13 | 416.36 | 20 | 15.15 | 861 | 261 | 2.96 / 233.30 | 2 | 2 |
6 | 13 | 78.08 | 20 | 15.21 | 380 | 116 | 3.08 / 233.41 | 2 | 2 |
7 | 13 | 21.96 | 20 | 15.20 | 297 | 90 | 3.17 / 233.50 | 2 | 2 |
8 | 8 | 0.24 | 165 | 15.18 | 258 | 646 | 3.81 / 234.15 | 2 | 4 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 29 | 15.15 | 405 | 178 | 0.18 / 226.68 | 3 | 3 |
2 | 7 | 2005.48 | 30 | 14.95 | 2900 | 1301 | 1.48 / 227.98 | 2 | 2 |
3 | 13 | 1611.40 | 20 | 14.96 | 2417 | 723 | 2.20 / 228.70 | 2 | 2 |
4 | 13 | 1031.88 | 20 | 15.03 | 1677 | 504 | 2.71 / 229.21 | 2 | 2 |
5 | 13 | 439.88 | 20 | 15.15 | 898 | 272 | 2.98 / 229.48 | 2 | 2 |
6 | 13 | 83.56 | 20 | 15.22 | 389 | 118 | 3.10 / 229.60 | 2 | 2 |
7 | 13 | 21.68 | 20 | 15.22 | 296 | 90 | 3.19 / 229.69 | 2 | 2 |
8 | 8 | 0.04 | 165 | 15.18 | 259 | 649 | 3.84 / 230.34 | 2 | 5 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 29 | 15.14 | 408 | 179 | 0.18 / 222.84 | 3 | 3 |
2 | 7 | 2002.52 | 30 | 14.99 | 2905 | 1306 | 1.49 / 224.15 | 2 | 3 |
3 | 13 | 1603.08 | 20 | 14.97 | 2415 | 723 | 2.21 / 224.87 | 2 | 3 |
4 | 13 | 1024.80 | 20 | 15.04 | 1678 | 505 | 2.71 / 225.38 | 2 | 3 |
5 | 13 | 425.40 | 20 | 15.18 | 883 | 268 | 2.98 / 225.64 | 2 | 2 |
6 | 13 | 84.08 | 20 | 15.24 | 387 | 118 | 3.10 / 225.76 | 2 | 2 |
7 | 13 | 22.12 | 20 | 15.24 | 298 | 91 | 3.19 / 225.85 | 2 | 2 |
8 | 8 | 0.04 | 165 | 15.21 | 258 | 647 | 3.84 / 226.50 | 2 | 6 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 29 | 15.15 | 401 | 176 | 0.18 / 219.02 | 3 | 3 |
2 | 7 | 2004.04 | 30 | 14.99 | 2903 | 1305 | 1.48 / 220.32 | 2 | 2 |
3 | 13 | 1587.72 | 20 | 14.98 | 2402 | 720 | 2.20 / 221.04 | 2 | 3 |
4 | 13 | 1010.36 | 20 | 15.06 | 1664 | 501 | 2.70 / 221.54 | 2 | 2 |
5 | 13 | 420.20 | 20 | 15.19 | 872 | 265 | 2.97 / 221.81 | 2 | 2 |
6 | 13 | 82.00 | 20 | 15.24 | 383 | 117 | 3.08 / 221.92 | 2 | 2 |
7 | 13 | 23.24 | 20 | 15.26 | 298 | 91 | 3.18 / 222.02 | 2 | 2 |
8 | 8 | 0.04 | 165 | 15.21 | 258 | 647 | 3.82 / 222.66 | 2 | 4 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.28 | 29 | 15.16 | 402 | 177 | 0.18 / 215.26 | 3 | 3 |
2 | 7 | 2002.84 | 30 | 14.96 | 2897 | 1300 | 1.48 / 216.56 | 2 | 2 |
3 | 13 | 1592.84 | 20 | 14.95 | 2402 | 718 | 2.20 / 217.28 | 2 | 2 |
4 | 13 | 1000.24 | 20 | 15.04 | 1642 | 494 | 2.69 / 217.77 | 2 | 3 |
5 | 13 | 294.00 | 20 | 15.21 | 685 | 208 | 2.90 / 217.98 | 2 | 2 |
6 | 13 | 94.00 | 20 | 15.25 | 398 | 121 | 3.02 / 218.10 | 2 | 2 |
7 | 13 | 24.32 | 20 | 15.23 | 300 | 91 | 3.11 / 218.20 | 2 | 2 |
8 | 8 | 0.04 | 165 | 15.20 | 257 | 645 | 3.75 / 218.84 | 2 | 6 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 29 | 15.15 | 410 | 180 | 0.18 / 211.49 | 3 | 3 |
2 | 7 | 2002.16 | 30 | 15.00 | 2904 | 1307 | 1.49 / 212.80 | 2 | 2 |
3 | 13 | 1721.40 | 20 | 14.97 | 2550 | 763 | 2.25 / 213.56 | 2 | 2 |
4 | 13 | 979.92 | 20 | 15.08 | 1616 | 487 | 2.74 / 214.05 | 2 | 3 |
5 | 13 | 397.08 | 20 | 15.20 | 842 | 256 | 2.99 / 214.30 | 2 | 2 |
6 | 13 | 120.80 | 20 | 15.25 | 438 | 134 | 3.13 / 214.44 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.21 | 258 | 647 | 3.77 / 215.09 | 2 | 7 |
Average= | 3.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.20 | 29 | 15.15 | 402 | 177 | 0.18 / 207.60 | 3 | 3 |
2 | 7 | 2003.36 | 31 | 15.00 | 2908 | 1352 | 1.53 / 208.95 | 2 | 2 |
3 | 13 | 1594.64 | 20 | 14.98 | 2407 | 721 | 2.25 / 209.67 | 2 | 3 |
4 | 13 | 1012.76 | 20 | 15.07 | 1663 | 501 | 2.75 / 210.17 | 2 | 2 |
5 | 13 | 411.48 | 20 | 15.20 | 857 | 261 | 3.01 / 210.43 | 2 | 2 |
6 | 13 | 130.92 | 20 | 15.25 | 451 | 138 | 3.15 / 210.57 | 2 | 2 |
7 | 13 | 30.32 | 20 | 15.26 | 308 | 94 | 3.24 / 210.66 | 2 | 2 |
8 | 8 | 0.08 | 165 | 15.22 | 258 | 648 | 3.89 / 211.31 | 2 | 9 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.08 | 29 | 15.16 | 398 | 175 | 0.17 / 203.75 | 3 | 3 |
2 | 7 | 2007.40 | 30 | 15.00 | 2914 | 1311 | 1.49 / 205.06 | 2 | 2 |
3 | 13 | 1593.40 | 20 | 15.00 | 2404 | 721 | 2.21 / 205.78 | 2 | 2 |
4 | 13 | 1011.68 | 20 | 15.07 | 1661 | 501 | 2.71 / 206.28 | 2 | 3 |
5 | 13 | 424.44 | 20 | 15.20 | 877 | 267 | 2.97 / 206.55 | 2 | 3 |
6 | 13 | 130.04 | 20 | 15.24 | 454 | 138 | 3.11 / 206.68 | 2 | 2 |
7 | 13 | 28.92 | 20 | 15.26 | 304 | 93 | 3.21 / 206.78 | 2 | 2 |
8 | 8 | 0.04 | 165 | 15.22 | 256 | 643 | 3.85 / 207.42 | 2 | 6 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.96 | 29 | 15.17 | 404 | 178 | 0.18 / 199.97 | 3 | 3 |
2 | 7 | 2008.08 | 30 | 15.01 | 2904 | 1308 | 1.49 / 201.28 | 2 | 3 |
3 | 13 | 1733.00 | 20 | 14.96 | 2579 | 772 | 2.26 / 202.05 | 2 | 3 |
4 | 13 | 979.76 | 20 | 15.07 | 1622 | 489 | 2.75 / 202.54 | 2 | 3 |
5 | 13 | 390.96 | 20 | 15.21 | 826 | 251 | 3.00 / 202.79 | 2 | 3 |
6 | 13 | 116.44 | 20 | 15.25 | 429 | 131 | 3.13 / 202.92 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.23 | 257 | 646 | 3.77 / 203.57 | 2 | 3 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.40 | 29 | 15.17 | 408 | 179 | 0.18 / 196.20 | 3 | 3 |
2 | 7 | 2008.08 | 30 | 15.00 | 2911 | 1310 | 1.49 / 197.51 | 2 | 2 |
3 | 13 | 1595.68 | 20 | 14.99 | 2408 | 722 | 2.21 / 198.24 | 2 | 2 |
4 | 13 | 1025.68 | 20 | 15.08 | 1677 | 506 | 2.72 / 198.74 | 2 | 2 |
5 | 13 | 424.64 | 20 | 15.21 | 875 | 266 | 2.98 / 199.01 | 2 | 3 |
6 | 13 | 128.40 | 20 | 15.26 | 451 | 138 | 3.12 / 199.15 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.23 | 259 | 651 | 3.77 / 199.80 | 2 | 4 |
Average= | 3.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 28 | 15.21 | 408 | 174 | 0.17 / 192.36 | 3 | 3 |
2 | 7 | 2006.84 | 30 | 14.99 | 2903 | 1305 | 1.48 / 193.67 | 2 | 3 |
3 | 13 | 1596.68 | 20 | 14.98 | 2405 | 721 | 2.20 / 194.39 | 2 | 2 |
4 | 13 | 1007.52 | 20 | 15.07 | 1657 | 499 | 2.70 / 194.89 | 2 | 2 |
5 | 13 | 410.32 | 20 | 15.20 | 858 | 261 | 2.96 / 195.15 | 2 | 2 |
6 | 13 | 133.52 | 20 | 15.25 | 453 | 138 | 3.10 / 195.29 | 2 | 2 |
7 | 13 | 29.56 | 20 | 15.27 | 306 | 93 | 3.19 / 195.38 | 2 | 2 |
8 | 8 | 0.04 | 165 | 15.24 | 257 | 646 | 3.84 / 196.02 | 2 | 7 |
Average= | 3.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.08 | 28 | 15.20 | 396 | 169 | 0.17 / 188.68 | 3 | 3 |
2 | 7 | 2003.12 | 30 | 15.01 | 2904 | 1308 | 1.48 / 189.99 | 2 | 3 |
3 | 13 | 1596.24 | 20 | 15.00 | 2410 | 723 | 2.20 / 190.71 | 2 | 2 |
4 | 13 | 1000.76 | 20 | 15.10 | 1645 | 497 | 2.70 / 191.21 | 2 | 2 |
5 | 13 | 297.88 | 20 | 15.25 | 694 | 212 | 2.91 / 191.42 | 2 | 2 |
6 | 13 | 93.56 | 20 | 15.27 | 394 | 120 | 3.03 / 191.54 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.24 | 257 | 646 | 3.67 / 192.19 | 2 | 3 |
Average= | 3.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 28 | 15.21 | 413 | 176 | 0.18 / 184.86 | 3 | 3 |
2 | 7 | 2007.64 | 30 | 15.00 | 2903 | 1306 | 1.48 / 186.16 | 2 | 2 |
3 | 13 | 1584.88 | 20 | 15.01 | 2395 | 719 | 2.20 / 186.88 | 2 | 2 |
4 | 13 | 997.08 | 20 | 15.10 | 1641 | 496 | 2.70 / 187.38 | 2 | 3 |
5 | 13 | 396.40 | 20 | 15.23 | 838 | 255 | 2.95 / 187.63 | 2 | 3 |
6 | 13 | 117.20 | 20 | 15.26 | 433 | 132 | 3.08 / 187.77 | 2 | 2 |
7 | 13 | 25.00 | 20 | 15.28 | 304 | 93 | 3.18 / 187.86 | 2 | 2 |
8 | 8 | 0.04 | 165 | 15.24 | 260 | 654 | 3.83 / 188.51 | 2 | 3 |
Average= | 3.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.04 | 28 | 15.22 | 409 | 174 | 0.17 / 181.01 | 2 | 3 |
2 | 7 | 2004.32 | 30 | 15.02 | 2908 | 1310 | 1.48 / 182.32 | 2 | 2 |
3 | 13 | 1602.72 | 20 | 15.00 | 2408 | 722 | 2.21 / 183.04 | 2 | 2 |
4 | 13 | 1016.12 | 20 | 15.11 | 1672 | 505 | 2.71 / 183.55 | 2 | 3 |
5 | 13 | 412.04 | 20 | 15.24 | 860 | 262 | 2.97 / 183.81 | 2 | 3 |
6 | 13 | 122.08 | 20 | 15.28 | 445 | 136 | 3.11 / 183.95 | 2 | 2 |
7 | 13 | 15.36 | 20 | 15.29 | 288 | 88 | 3.20 / 184.03 | 2 | 2 |
8 | 8 | -0.04 | 165 | 15.23 | 258 | 648 | 3.85 / 184.68 | 2 | 4 |
Average= | 3.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 28 | 15.19 | 411 | 175 | 0.17 / 177.14 | 3 | 3 |
2 | 7 | 2003.24 | 30 | 15.02 | 2905 | 1309 | 1.48 / 178.45 | 2 | 3 |
3 | 13 | 1721.48 | 20 | 14.99 | 2563 | 768 | 2.25 / 179.22 | 2 | 2 |
4 | 13 | 1112.88 | 20 | 15.08 | 1791 | 540 | 2.79 / 179.76 | 2 | 2 |
5 | 13 | 493.52 | 20 | 15.21 | 968 | 294 | 3.09 / 180.05 | 2 | 2 |
6 | 13 | 123.20 | 20 | 15.28 | 442 | 135 | 3.22 / 180.19 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.26 | 258 | 650 | 3.87 / 180.83 | 2 | 3 |
Average= | 3.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 28 | 15.21 | 404 | 172 | 0.17 / 173.25 | 3 | 3 |
2 | 7 | 2005.44 | 31 | 15.02 | 2899 | 1350 | 1.52 / 174.60 | 2 | 2 |
3 | 13 | 1582.16 | 20 | 15.02 | 2396 | 720 | 2.24 / 175.32 | 2 | 2 |
4 | 13 | 987.84 | 20 | 15.10 | 1631 | 493 | 2.73 / 175.81 | 2 | 2 |
5 | 13 | 388.00 | 20 | 15.23 | 828 | 252 | 2.99 / 176.06 | 2 | 3 |
6 | 13 | 114.32 | 20 | 15.27 | 437 | 133 | 3.12 / 176.20 | 2 | 2 |
7 | 13 | 60.52 | 20 | 15.28 | 356 | 109 | 3.23 / 176.31 | 2 | 2 |
8 | 8 | -0.04 | 165 | 15.24 | 261 | 656 | 3.88 / 176.96 | 2 | 4 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 28 | 15.20 | 407 | 173 | 0.17 / 169.67 | 3 | 3 |
2 | 7 | 2008.84 | 30 | 15.00 | 2906 | 1308 | 1.48 / 170.97 | 2 | 2 |
3 | 13 | 1475.76 | 20 | 15.03 | 2267 | 681 | 2.16 / 171.65 | 2 | 2 |
4 | 13 | 929.88 | 20 | 15.12 | 1550 | 469 | 2.63 / 172.12 | 2 | 2 |
5 | 13 | 242.88 | 20 | 15.26 | 616 | 188 | 2.82 / 172.31 | 2 | 2 |
6 | 13 | 78.44 | 20 | 15.29 | 377 | 115 | 2.93 / 172.43 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.26 | 259 | 652 | 3.59 / 173.08 | 2 | 5 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.16 | 28 | 15.22 | 399 | 170 | 0.17 / 165.88 | 3 | 3 |
2 | 7 | 2009.12 | 30 | 14.99 | 2897 | 1303 | 1.47 / 167.18 | 2 | 2 |
3 | 13 | 1609.92 | 20 | 15.00 | 2425 | 727 | 2.20 / 167.91 | 2 | 2 |
4 | 13 | 1017.80 | 20 | 15.09 | 1674 | 505 | 2.71 / 168.41 | 2 | 2 |
5 | 13 | 292.16 | 20 | 15.26 | 691 | 211 | 2.92 / 168.62 | 2 | 2 |
6 | 13 | 81.60 | 20 | 15.30 | 385 | 118 | 3.03 / 168.74 | 2 | 2 |
7 | 13 | 20.28 | 20 | 15.29 | 298 | 91 | 3.13 / 168.83 | 2 | 2 |
8 | 8 | 0.00 | 165 | 15.25 | 262 | 659 | 3.78 / 169.49 | 2 | 4 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 28 | 15.21 | 400 | 170 | 0.17 / 162.10 | 2 | 3 |
2 | 7 | 2005.12 | 30 | 15.03 | 2911 | 1313 | 1.48 / 163.42 | 2 | 2 |
3 | 13 | 1473.64 | 20 | 15.05 | 2252 | 678 | 2.16 / 164.09 | 2 | 2 |
4 | 13 | 919.92 | 20 | 15.14 | 1546 | 468 | 2.63 / 164.56 | 2 | 3 |
5 | 13 | 356.68 | 20 | 15.26 | 784 | 239 | 2.87 / 164.80 | 2 | 3 |
6 | 13 | 100.76 | 20 | 15.31 | 416 | 127 | 3.00 / 164.93 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.27 | 261 | 658 | 3.65 / 165.59 | 2 | 8 |
8 | 14 | 0.08 | 30 | 15.26 | 263 | 120 | 3.77 / 165.71 | 3 | 7 |
Average= | 3.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.32 | 28 | 15.22 | 398 | 170 | 0.17 / 158.38 | 3 | 3 |
2 | 7 | 2003.16 | 30 | 15.02 | 2904 | 1309 | 1.48 / 159.69 | 2 | 2 |
3 | 13 | 1585.16 | 20 | 15.02 | 2388 | 717 | 2.20 / 160.41 | 2 | 3 |
4 | 13 | 992.08 | 20 | 15.13 | 1635 | 495 | 2.69 / 160.90 | 2 | 3 |
5 | 13 | 407.84 | 20 | 15.25 | 858 | 262 | 2.95 / 161.17 | 2 | 2 |
6 | 13 | 70.40 | 20 | 15.31 | 368 | 113 | 3.06 / 161.28 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.26 | 260 | 655 | 3.72 / 161.93 | 2 | 6 |
Average= | 3.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 28 | 15.23 | 405 | 173 | 0.17 / 154.64 | 2 | 3 |
2 | 7 | 2005.80 | 30 | 15.03 | 2903 | 1309 | 1.48 / 155.95 | 2 | 3 |
3 | 13 | 1602.64 | 20 | 15.01 | 2412 | 724 | 2.21 / 156.67 | 2 | 2 |
4 | 13 | 1010.04 | 20 | 15.12 | 1668 | 504 | 2.71 / 157.18 | 2 | 2 |
5 | 13 | 420.12 | 20 | 15.24 | 872 | 266 | 2.98 / 157.44 | 2 | 2 |
6 | 13 | 67.56 | 20 | 15.31 | 365 | 112 | 3.09 / 157.56 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.28 | 261 | 658 | 3.75 / 158.21 | 2 | 12 |
Average= | 3.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.20 | 28 | 15.23 | 420 | 179 | 0.18 / 150.88 | 2 | 3 |
2 | 7 | 2002.04 | 30 | 15.03 | 2908 | 1311 | 1.49 / 152.20 | 2 | 3 |
3 | 13 | 1580.36 | 20 | 15.04 | 2391 | 719 | 2.21 / 152.92 | 2 | 2 |
4 | 13 | 1009.16 | 20 | 15.12 | 1660 | 502 | 2.71 / 153.42 | 2 | 2 |
5 | 13 | 401.32 | 20 | 15.26 | 846 | 258 | 2.97 / 153.68 | 2 | 2 |
6 | 13 | 110.96 | 20 | 15.31 | 428 | 131 | 3.10 / 153.81 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.26 | 263 | 662 | 3.76 / 154.47 | 2 | 4 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.68 | 28 | 15.25 | 403 | 172 | 0.17 / 147.09 | 2 | 3 |
2 | 7 | 2005.48 | 30 | 15.03 | 2906 | 1310 | 1.48 / 148.40 | 2 | 2 |
3 | 13 | 1746.36 | 20 | 14.99 | 2591 | 777 | 2.26 / 149.17 | 2 | 2 |
4 | 13 | 991.20 | 20 | 15.14 | 1639 | 496 | 2.76 / 149.67 | 2 | 3 |
5 | 13 | 400.20 | 20 | 15.27 | 845 | 258 | 3.01 / 149.93 | 2 | 3 |
6 | 13 | 71.04 | 20 | 15.32 | 370 | 113 | 3.13 / 150.04 | 2 | 2 |
7 | 8 | -0.12 | 165 | 15.28 | 263 | 663 | 3.79 / 150.71 | 2 | 3 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 28 | 15.25 | 399 | 170 | 0.17 / 143.35 | 3 | 3 |
2 | 7 | 2006.88 | 31 | 15.03 | 2918 | 1360 | 1.53 / 144.71 | 2 | 2 |
3 | 13 | 1584.16 | 20 | 15.03 | 2386 | 717 | 2.25 / 145.43 | 2 | 2 |
4 | 13 | 991.00 | 20 | 15.12 | 1636 | 495 | 2.74 / 145.92 | 2 | 2 |
5 | 13 | 290.32 | 20 | 15.29 | 687 | 210 | 2.95 / 146.13 | 2 | 3 |
6 | 13 | 72.80 | 20 | 15.31 | 375 | 115 | 3.07 / 146.24 | 2 | 3 |
7 | 8 | 0.08 | 165 | 15.29 | 266 | 671 | 3.74 / 146.92 | 2 | 4 |
Average= | 3.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.28 | 28 | 15.26 | 404 | 173 | 0.17 / 139.66 | 2 | 3 |
2 | 7 | 2005.64 | 30 | 15.02 | 2900 | 1307 | 1.48 / 140.97 | 2 | 2 |
3 | 13 | 1589.68 | 20 | 15.02 | 2405 | 722 | 2.20 / 141.69 | 2 | 2 |
4 | 13 | 1009.20 | 20 | 15.12 | 1660 | 502 | 2.70 / 142.19 | 2 | 3 |
5 | 13 | 287.28 | 20 | 15.30 | 678 | 207 | 2.91 / 142.40 | 2 | 2 |
6 | 13 | 81.16 | 20 | 15.30 | 384 | 118 | 3.03 / 142.52 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.29 | 262 | 661 | 3.69 / 143.18 | 2 | 4 |
Average= | 3.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 120.96 | 28 | 15.24 | 426 | 182 | 0.18 / 135.86 | 3 | 3 |
2 | 7 | 2007.20 | 31 | 15.04 | 2909 | 1356 | 1.54 / 137.22 | 2 | 2 |
3 | 13 | 1599.92 | 20 | 15.04 | 2416 | 727 | 2.26 / 137.95 | 2 | 2 |
4 | 13 | 1011.80 | 20 | 15.14 | 1671 | 506 | 2.77 / 138.45 | 2 | 3 |
5 | 13 | 418.64 | 20 | 15.26 | 865 | 264 | 3.03 / 138.72 | 2 | 3 |
6 | 13 | 69.24 | 20 | 15.31 | 366 | 112 | 3.15 / 138.83 | 2 | 3 |
7 | 8 | 0.16 | 165 | 15.30 | 261 | 659 | 3.81 / 139.49 | 2 | 4 |
Average= | 3.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 28 | 15.25 | 409 | 175 | 0.17 / 132.18 | 2 | 3 |
2 | 7 | 2006.60 | 30 | 15.01 | 2896 | 1304 | 1.48 / 133.48 | 2 | 2 |
3 | 13 | 1600.04 | 20 | 15.01 | 2412 | 724 | 2.20 / 134.20 | 2 | 2 |
4 | 13 | 1015.84 | 20 | 15.11 | 1664 | 503 | 2.71 / 134.71 | 2 | 2 |
5 | 13 | 284.64 | 20 | 15.27 | 673 | 206 | 2.91 / 134.91 | 2 | 3 |
6 | 13 | 71.44 | 20 | 15.30 | 367 | 112 | 3.02 / 135.02 | 2 | 2 |
7 | 8 | 0.00 | 165 | 15.28 | 261 | 658 | 3.68 / 135.68 | 2 | 3 |
Average= | 3.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.48 | 28 | 15.24 | 407 | 174 | 0.17 / 128.52 | 2 | 3 |
2 | 7 | 2003.44 | 30 | 15.05 | 2899 | 1309 | 1.48 / 129.83 | 2 | 2 |
3 | 13 | 1479.00 | 20 | 15.07 | 2256 | 680 | 2.16 / 130.51 | 2 | 2 |
4 | 13 | 933.96 | 20 | 15.18 | 1564 | 475 | 2.64 / 130.98 | 2 | 2 |
5 | 13 | 331.08 | 20 | 15.30 | 751 | 230 | 2.87 / 131.21 | 2 | 2 |
6 | 13 | 86.52 | 20 | 15.32 | 398 | 122 | 2.99 / 131.33 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.28 | 265 | 668 | 3.66 / 132.00 | 2 | 2 |
Average= | 3.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 119.32 | 28 | 15.23 | 419 | 179 | 0.18 / 124.87 | 3 | 3 |
2 | 7 | 2005.00 | 30 | 15.03 | 2902 | 1309 | 1.49 / 126.18 | 2 | 2 |
3 | 13 | 1483.00 | 20 | 15.06 | 2265 | 682 | 2.17 / 126.87 | 2 | 3 |
4 | 13 | 931.44 | 20 | 15.15 | 1557 | 472 | 2.64 / 127.34 | 2 | 2 |
5 | 13 | 344.72 | 20 | 15.27 | 765 | 234 | 2.87 / 127.57 | 2 | 2 |
6 | 13 | 51.16 | 20 | 15.32 | 344 | 105 | 2.98 / 127.68 | 2 | 3 |
7 | 8 | 0.00 | 165 | 15.27 | 265 | 668 | 3.65 / 128.34 | 2 | 5 |
Average= | 3.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 28 | 15.24 | 401 | 171 | 0.17 / 121.12 | 2 | 3 |
2 | 7 | 2007.44 | 30 | 15.03 | 2898 | 1307 | 1.48 / 122.43 | 2 | 2 |
3 | 13 | 1594.60 | 20 | 15.03 | 2398 | 721 | 2.20 / 123.15 | 2 | 2 |
4 | 13 | 1020.88 | 20 | 15.13 | 1670 | 505 | 2.70 / 123.66 | 2 | 2 |
5 | 13 | 424.04 | 20 | 15.25 | 879 | 268 | 2.97 / 123.92 | 2 | 2 |
6 | 13 | 74.84 | 20 | 15.31 | 377 | 115 | 3.09 / 124.04 | 2 | 2 |
7 | 8 | 0.24 | 165 | 15.28 | 260 | 656 | 3.74 / 124.70 | 2 | 3 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.56 | 28 | 15.25 | 403 | 172 | 0.17 / 117.38 | 2 | 3 |
2 | 7 | 2008.76 | 30 | 15.05 | 2907 | 1313 | 1.48 / 118.70 | 2 | 2 |
3 | 13 | 1597.40 | 20 | 15.06 | 2409 | 726 | 2.21 / 119.42 | 2 | 2 |
4 | 13 | 1011.68 | 20 | 15.16 | 1663 | 504 | 2.71 / 119.92 | 2 | 2 |
5 | 13 | 408.44 | 20 | 15.28 | 854 | 261 | 2.98 / 120.19 | 2 | 2 |
6 | 13 | 72.16 | 20 | 15.34 | 368 | 113 | 3.09 / 120.30 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.30 | 259 | 654 | 3.74 / 120.95 | 2 | 5 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.76 | 28 | 15.25 | 397 | 170 | 0.17 / 113.75 | 2 | 3 |
2 | 7 | 2002.80 | 30 | 15.05 | 2894 | 1307 | 1.48 / 115.06 | 2 | 2 |
3 | 13 | 1577.40 | 20 | 15.06 | 2378 | 716 | 2.19 / 115.77 | 2 | 2 |
4 | 13 | 869.12 | 20 | 15.19 | 1470 | 447 | 2.64 / 116.22 | 2 | 2 |
5 | 13 | 313.44 | 20 | 15.30 | 720 | 220 | 2.86 / 116.44 | 2 | 2 |
6 | 13 | 85.44 | 20 | 15.33 | 386 | 118 | 2.98 / 116.56 | 2 | 2 |
7 | 8 | 0.32 | 165 | 15.30 | 259 | 654 | 3.63 / 117.21 | 2 | 5 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 28 | 15.26 | 406 | 173 | 0.17 / 110.04 | 2 | 3 |
2 | 7 | 2003.48 | 31 | 15.05 | 2893 | 1350 | 1.52 / 111.39 | 2 | 2 |
3 | 13 | 1589.08 | 20 | 15.06 | 2396 | 722 | 2.24 / 112.11 | 2 | 2 |
4 | 13 | 998.48 | 20 | 15.16 | 1636 | 496 | 2.74 / 112.61 | 2 | 2 |
5 | 13 | 272.32 | 20 | 15.31 | 664 | 203 | 2.94 / 112.81 | 2 | 2 |
6 | 13 | 72.20 | 20 | 15.32 | 368 | 113 | 3.06 / 112.92 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.30 | 260 | 656 | 3.71 / 113.58 | 2 | 7 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 28 | 15.26 | 405 | 173 | 0.17 / 106.32 | 3 | 3 |
2 | 7 | 2006.32 | 30 | 15.05 | 2910 | 1314 | 1.49 / 107.63 | 2 | 2 |
3 | 13 | 1581.32 | 20 | 15.05 | 2377 | 715 | 2.20 / 108.35 | 2 | 2 |
4 | 13 | 997.76 | 20 | 15.16 | 1642 | 498 | 2.70 / 108.85 | 2 | 2 |
5 | 13 | 387.04 | 20 | 15.28 | 819 | 250 | 2.95 / 109.10 | 2 | 2 |
6 | 13 | 75.08 | 20 | 15.32 | 374 | 115 | 3.07 / 109.21 | 2 | 2 |
7 | 8 | 0.00 | 165 | 15.29 | 259 | 653 | 3.72 / 109.87 | 2 | 7 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 28 | 15.26 | 398 | 170 | 0.17 / 102.46 | 3 | 3 |
2 | 7 | 2002.12 | 30 | 15.05 | 2896 | 1308 | 1.48 / 103.77 | 2 | 2 |
3 | 13 | 1719.08 | 20 | 15.03 | 2558 | 769 | 2.25 / 104.53 | 2 | 2 |
4 | 13 | 961.12 | 20 | 15.16 | 1594 | 483 | 2.73 / 105.02 | 2 | 2 |
5 | 13 | 371.36 | 20 | 15.28 | 803 | 245 | 2.98 / 105.26 | 2 | 2 |
6 | 13 | 73.00 | 20 | 15.33 | 371 | 114 | 3.09 / 105.38 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.30 | 258 | 651 | 3.74 / 106.03 | 2 | 6 |
8 | 14 | 0.04 | 30 | 15.28 | 259 | 119 | 3.86 / 106.15 | 2 | 4 |
Average= | 3.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.04 | 28 | 15.26 | 408 | 174 | 0.17 / 98.72 | 2 | 3 |
2 | 7 | 2006.88 | 30 | 15.06 | 2911 | 1315 | 1.49 / 100.04 | 2 | 2 |
3 | 13 | 1599.88 | 20 | 15.08 | 2414 | 728 | 2.22 / 100.76 | 2 | 2 |
4 | 13 | 1004.36 | 20 | 15.16 | 1648 | 500 | 2.72 / 101.26 | 2 | 2 |
5 | 13 | 401.24 | 20 | 15.29 | 849 | 260 | 2.98 / 101.52 | 2 | 2 |
6 | 13 | 70.68 | 20 | 15.35 | 366 | 112 | 3.09 / 101.64 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.32 | 258 | 652 | 3.74 / 102.29 | 2 | 3 |
Average= | 3.53 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 28 | 15.26 | 390 | 167 | 0.17 / 94.98 | 3 | 3 |
2 | 7 | 2002.44 | 30 | 15.05 | 2898 | 1308 | 1.48 / 96.29 | 2 | 2 |
3 | 13 | 1598.24 | 20 | 15.05 | 2402 | 723 | 2.20 / 97.01 | 2 | 2 |
4 | 13 | 997.76 | 20 | 15.15 | 1640 | 497 | 2.70 / 97.51 | 2 | 2 |
5 | 13 | 394.12 | 20 | 15.29 | 830 | 254 | 2.95 / 97.76 | 2 | 2 |
6 | 13 | 106.64 | 20 | 15.33 | 422 | 129 | 3.08 / 97.89 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.30 | 260 | 656 | 3.73 / 98.55 | 2 | 4 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.96 | 28 | 15.28 | 415 | 178 | 0.18 / 91.29 | 2 | 3 |
2 | 7 | 2007.80 | 30 | 15.04 | 2901 | 1309 | 1.49 / 92.60 | 2 | 2 |
3 | 13 | 1473.08 | 20 | 15.08 | 2245 | 677 | 2.16 / 93.27 | 2 | 2 |
4 | 13 | 896.96 | 20 | 15.18 | 1511 | 459 | 2.62 / 93.73 | 2 | 2 |
5 | 13 | 320.88 | 20 | 15.30 | 727 | 222 | 2.84 / 93.95 | 2 | 2 |
6 | 13 | 84.56 | 20 | 15.33 | 389 | 119 | 2.96 / 94.07 | 2 | 2 |
7 | 13 | 21.40 | 20 | 15.33 | 297 | 91 | 3.06 / 94.16 | 2 | 2 |
8 | 8 | 0.16 | 165 | 15.29 | 257 | 648 | 3.70 / 94.81 | 2 | 5 |
Average= | 3.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.36 | 28 | 15.28 | 406 | 174 | 0.17 / 87.61 | 2 | 3 |
2 | 7 | 2002.00 | 30 | 15.02 | 2892 | 1303 | 1.48 / 88.91 | 2 | 2 |
3 | 13 | 1583.84 | 20 | 15.03 | 2385 | 717 | 2.19 / 89.63 | 2 | 2 |
4 | 13 | 989.16 | 20 | 15.14 | 1636 | 495 | 2.69 / 90.13 | 2 | 2 |
5 | 13 | 272.40 | 20 | 15.31 | 662 | 203 | 2.89 / 90.33 | 2 | 2 |
6 | 13 | 57.64 | 20 | 15.34 | 357 | 110 | 3.00 / 90.44 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.31 | 265 | 669 | 3.67 / 91.11 | 2 | 6 |
Average= | 3.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 28 | 15.27 | 400 | 171 | 0.17 / 83.86 | 3 | 3 |
2 | 7 | 2002.60 | 30 | 15.08 | 2900 | 1312 | 1.48 / 85.18 | 2 | 2 |
3 | 13 | 1586.56 | 20 | 15.09 | 2392 | 722 | 2.20 / 85.90 | 2 | 2 |
4 | 13 | 997.76 | 20 | 15.17 | 1647 | 500 | 2.70 / 86.40 | 2 | 2 |
5 | 13 | 392.04 | 20 | 15.32 | 839 | 257 | 2.96 / 86.65 | 2 | 2 |
6 | 13 | 62.16 | 20 | 15.36 | 368 | 113 | 3.07 / 86.77 | 2 | 2 |
7 | 8 | 0.20 | 165 | 15.33 | 265 | 670 | 3.75 / 87.44 | 2 | 3 |
Average= | 3.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 28 | 15.28 | 403 | 172 | 0.17 / 80.04 | 3 | 3 |
2 | 7 | 2001.72 | 30 | 15.08 | 2894 | 1309 | 1.48 / 81.35 | 2 | 2 |
3 | 13 | 1571.80 | 20 | 15.10 | 2376 | 718 | 2.20 / 82.07 | 2 | 2 |
4 | 13 | 975.84 | 20 | 15.19 | 1611 | 489 | 2.69 / 82.56 | 2 | 2 |
5 | 13 | 369.48 | 20 | 15.33 | 801 | 246 | 2.93 / 82.80 | 2 | 2 |
6 | 13 | 67.08 | 20 | 15.35 | 362 | 111 | 3.05 / 82.91 | 2 | 2 |
7 | 8 | 0.68 | 165 | 15.32 | 261 | 660 | 3.71 / 83.57 | 2 | 4 |
8 | 14 | 0.68 | 30 | 15.31 | 260 | 119 | 3.82 / 83.69 | 2 | 5 |
Average= | 3.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.00 | 28 | 15.30 | 407 | 174 | 0.17 / 76.41 | 3 | 3 |
2 | 7 | 1857.60 | 31 | 15.12 | 2724 | 1277 | 1.45 / 77.68 | 2 | 2 |
3 | 13 | 1469.60 | 20 | 15.13 | 2252 | 681 | 2.13 / 78.37 | 2 | 2 |
4 | 13 | 1043.72 | 20 | 15.19 | 1701 | 517 | 2.65 / 78.88 | 2 | 2 |
5 | 13 | 287.84 | 20 | 15.35 | 680 | 209 | 2.86 / 79.09 | 2 | 2 |
6 | 13 | 76.52 | 20 | 15.36 | 380 | 117 | 2.97 / 79.21 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.34 | 261 | 661 | 3.64 / 79.87 | 2 | 5 |
Average= | 3.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 28 | 15.27 | 398 | 170 | 0.17 / 72.67 | 3 | 3 |
2 | 7 | 2006.48 | 30 | 15.05 | 2904 | 1311 | 1.48 / 73.98 | 2 | 2 |
3 | 13 | 1602.68 | 20 | 15.06 | 2410 | 726 | 2.21 / 74.71 | 2 | 2 |
4 | 13 | 1001.48 | 20 | 15.18 | 1646 | 500 | 2.71 / 75.21 | 2 | 2 |
5 | 13 | 399.36 | 20 | 15.30 | 845 | 259 | 2.97 / 75.47 | 2 | 2 |
6 | 13 | 69.44 | 20 | 15.35 | 367 | 113 | 3.08 / 75.58 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.32 | 259 | 655 | 3.73 / 76.23 | 2 | 4 |
Average= | 3.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.32 | 28 | 15.31 | 399 | 171 | 0.17 / 69.03 | 3 | 3 |
2 | 7 | 2006.84 | 30 | 15.08 | 2903 | 1313 | 1.48 / 70.34 | 2 | 2 |
3 | 13 | 1590.12 | 20 | 15.10 | 2397 | 724 | 2.21 / 71.07 | 2 | 2 |
4 | 13 | 878.20 | 20 | 15.22 | 1495 | 455 | 2.66 / 71.52 | 2 | 2 |
5 | 13 | 300.04 | 20 | 15.35 | 701 | 215 | 2.88 / 71.74 | 2 | 2 |
6 | 13 | 43.76 | 20 | 15.37 | 334 | 103 | 2.98 / 71.84 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.33 | 261 | 660 | 3.64 / 72.50 | 2 | 5 |
Average= | 3.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 28 | 15.28 | 393 | 168 | 0.17 / 65.35 | 3 | 3 |
2 | 7 | 2001.92 | 30 | 15.09 | 2899 | 1312 | 1.48 / 66.66 | 2 | 2 |
3 | 13 | 1590.44 | 20 | 15.12 | 2399 | 725 | 2.21 / 67.39 | 2 | 2 |
4 | 13 | 976.72 | 20 | 15.21 | 1622 | 493 | 2.70 / 67.88 | 2 | 2 |
5 | 13 | 272.52 | 20 | 15.35 | 662 | 203 | 2.90 / 68.08 | 2 | 2 |
6 | 13 | 59.92 | 20 | 15.38 | 357 | 110 | 3.01 / 68.19 | 2 | 2 |
7 | 8 | 0.00 | 165 | 15.35 | 263 | 666 | 3.68 / 68.86 | 2 | 3 |
Average= | 3.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 28 | 15.30 | 397 | 170 | 0.17 / 61.64 | 3 | 3 |
2 | 7 | 2005.40 | 30 | 15.08 | 2902 | 1313 | 1.48 / 62.95 | 2 | 2 |
3 | 13 | 1447.16 | 20 | 15.13 | 2213 | 670 | 2.15 / 63.62 | 2 | 2 |
4 | 13 | 889.16 | 20 | 15.22 | 1500 | 457 | 2.61 / 64.08 | 2 | 2 |
5 | 13 | 326.88 | 20 | 15.33 | 737 | 226 | 2.84 / 64.31 | 2 | 2 |
6 | 13 | 46.04 | 20 | 15.35 | 331 | 102 | 2.94 / 64.41 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.34 | 258 | 653 | 3.59 / 65.06 | 2 | 6 |
8 | 14 | 0.08 | 30 | 15.33 | 257 | 118 | 3.71 / 65.18 | 2 | 4 |
Average= | 3.43 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.04 | 28 | 15.30 | 395 | 169 | 0.17 / 58.11 | 2 | 3 |
2 | 7 | 1824.80 | 30 | 15.15 | 2684 | 1220 | 1.39 / 59.33 | 2 | 2 |
3 | 13 | 1561.60 | 20 | 15.14 | 2359 | 714 | 2.10 / 60.04 | 2 | 2 |
4 | 13 | 937.68 | 20 | 15.23 | 1568 | 478 | 2.58 / 60.52 | 2 | 2 |
5 | 13 | 232.04 | 20 | 15.37 | 600 | 184 | 2.77 / 60.71 | 2 | 2 |
6 | 13 | 61.52 | 20 | 15.38 | 354 | 109 | 2.87 / 60.82 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.35 | 259 | 656 | 3.53 / 61.47 | 2 | 5 |
Average= | 3.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.04 | 28 | 15.32 | 400 | 172 | 0.17 / 54.54 | 3 | 3 |
2 | 7 | 2003.24 | 30 | 15.11 | 2897 | 1313 | 1.48 / 55.86 | 2 | 2 |
3 | 13 | 1580.60 | 20 | 15.13 | 2379 | 720 | 2.20 / 56.58 | 2 | 2 |
4 | 13 | 873.28 | 20 | 15.25 | 1480 | 451 | 2.66 / 57.03 | 2 | 2 |
5 | 13 | 195.76 | 20 | 15.38 | 538 | 165 | 2.82 / 57.19 | 2 | 2 |
6 | 13 | 58.40 | 20 | 15.39 | 343 | 106 | 2.93 / 57.30 | 2 | 2 |
7 | 8 | 0.12 | 165 | 15.36 | 253 | 641 | 3.57 / 57.94 | 2 | 3 |
Average= | 3.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 28 | 15.30 | 398 | 171 | 0.17 / 50.80 | 3 | 3 |
2 | 7 | 2003.52 | 30 | 15.11 | 2902 | 1315 | 1.49 / 52.11 | 2 | 2 |
3 | 13 | 1591.92 | 20 | 15.13 | 2399 | 726 | 2.21 / 52.84 | 2 | 2 |
4 | 13 | 995.20 | 20 | 15.23 | 1641 | 500 | 2.71 / 53.34 | 2 | 2 |
5 | 13 | 380.40 | 20 | 15.35 | 817 | 251 | 2.96 / 53.59 | 2 | 2 |
6 | 13 | 101.60 | 20 | 15.39 | 414 | 127 | 3.09 / 53.72 | 2 | 2 |
7 | 8 | 0.04 | 165 | 15.35 | 259 | 656 | 3.75 / 54.37 | 2 | 4 |
Average= | 3.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 28 | 15.28 | 399 | 171 | 0.17 / 46.97 | 3 | 3 |
2 | 7 | 2002.28 | 30 | 15.11 | 2904 | 1316 | 1.49 / 48.28 | 2 | 2 |
3 | 13 | 1596.20 | 18 | 15.13 | 2414 | 657 | 2.14 / 48.94 | 2 | 2 |
4 | 13 | 1014.96 | 18 | 15.22 | 1673 | 458 | 2.60 / 49.40 | 2 | 2 |
5 | 13 | 449.28 | 18 | 15.33 | 912 | 252 | 2.85 / 49.65 | 2 | 2 |
6 | 13 | 103.52 | 18 | 15.38 | 416 | 115 | 2.97 / 49.77 | 2 | 2 |
7 | 13 | 55.20 | 18 | 15.37 | 342 | 95 | 3.06 / 49.86 | 2 | 2 |
8 | 8 | 0.12 | 165 | 15.34 | 257 | 650 | 3.71 / 50.51 | 2 | 4 |
9 | 14 | 0.12 | 30 | 15.32 | 254 | 117 | 3.83 / 50.63 | 4 | 6 |
Average= | 3.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.32 | 28 | 15.29 | 401 | 172 | 0.17 / 43.13 | 3 | 3 |
2 | 7 | 2003.88 | 31 | 15.11 | 2903 | 1360 | 1.53 / 44.49 | 2 | 2 |
3 | 13 | 1595.44 | 18 | 15.13 | 2404 | 655 | 2.19 / 45.14 | 2 | 2 |
4 | 13 | 1147.52 | 18 | 15.18 | 1839 | 502 | 2.69 / 45.64 | 2 | 2 |
5 | 13 | 540.92 | 18 | 15.30 | 1038 | 286 | 2.97 / 45.93 | 2 | 2 |
6 | 13 | 123.12 | 18 | 15.37 | 451 | 125 | 3.10 / 46.05 | 2 | 2 |
7 | 13 | 34.20 | 18 | 15.39 | 312 | 86 | 3.19 / 46.14 | 2 | 2 |
8 | 8 | 0.04 | 165 | 15.35 | 259 | 656 | 3.84 / 46.80 | 2 | 4 |
Average= | 3.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.36 | 27 | 15.30 | 398 | 164 | 0.16 / 39.38 | 3 | 3 |
2 | 7 | 2003.72 | 30 | 15.10 | 2900 | 1314 | 1.48 / 40.70 | 2 | 2 |
3 | 13 | 1583.44 | 18 | 15.12 | 2393 | 651 | 2.13 / 41.35 | 2 | 2 |
4 | 13 | 1142.04 | 18 | 15.18 | 1833 | 501 | 2.63 / 41.85 | 2 | 2 |
5 | 13 | 408.88 | 18 | 15.33 | 857 | 236 | 2.87 / 42.09 | 2 | 2 |
6 | 13 | 123.28 | 18 | 15.37 | 446 | 123 | 2.99 / 42.21 | 2 | 2 |
7 | 13 | 36.56 | 18 | 15.37 | 319 | 88 | 3.08 / 42.30 | 2 | 2 |
8 | 8 | 0.04 | 165 | 15.34 | 259 | 656 | 3.73 / 42.95 | 2 | 4 |
Average= | 3.30 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 27 | 15.32 | 401 | 166 | 0.17 / 35.68 | 3 | 3 |
2 | 7 | 2005.60 | 30 | 15.09 | 2905 | 1315 | 1.48 / 37.00 | 2 | 2 |
3 | 13 | 1601.80 | 18 | 15.09 | 2410 | 655 | 2.14 / 37.65 | 2 | 2 |
4 | 13 | 1028.80 | 18 | 15.18 | 1681 | 459 | 2.59 / 38.11 | 2 | 2 |
5 | 13 | 459.40 | 18 | 15.32 | 926 | 255 | 2.85 / 38.37 | 2 | 2 |
6 | 13 | 96.52 | 18 | 15.38 | 405 | 112 | 2.96 / 38.48 | 2 | 2 |
7 | 13 | 24.40 | 18 | 15.39 | 302 | 84 | 3.05 / 38.56 | 2 | 2 |
8 | 8 | 0.12 | 165 | 15.36 | 259 | 656 | 3.70 / 39.22 | 2 | 4 |
Average= | 3.27 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 27 | 15.32 | 401 | 166 | 0.17 / 32.04 | 3 | 3 |
2 | 7 | 2004.60 | 30 | 15.12 | 2902 | 1316 | 1.48 / 33.36 | 2 | 2 |
3 | 13 | 1465.60 | 18 | 15.16 | 2238 | 611 | 2.09 / 33.97 | 2 | 2 |
4 | 13 | 911.24 | 18 | 15.25 | 1535 | 421 | 2.51 / 34.39 | 2 | 2 |
5 | 13 | 483.80 | 18 | 15.33 | 964 | 266 | 2.78 / 34.66 | 2 | 2 |
6 | 13 | 99.88 | 18 | 15.39 | 409 | 113 | 2.89 / 34.77 | 2 | 2 |
7 | 13 | 24.08 | 18 | 15.39 | 304 | 84 | 2.98 / 34.86 | 2 | 2 |
8 | 8 | 0.00 | 165 | 15.37 | 261 | 662 | 3.64 / 35.52 | 2 | 6 |
Average= | 3.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.48 | 27 | 15.32 | 415 | 172 | 0.17 / 28.59 | 3 | 3 |
2 | 7 | 1649.08 | 30 | 15.22 | 2464 | 1125 | 1.30 / 29.71 | 2 | 2 |
3 | 13 | 1523.36 | 18 | 15.19 | 2317 | 634 | 1.93 / 30.34 | 2 | 2 |
4 | 13 | 834.36 | 18 | 15.29 | 1430 | 394 | 2.32 / 30.74 | 2 | 2 |
5 | 13 | 419.32 | 18 | 15.37 | 874 | 242 | 2.57 / 30.98 | 2 | 2 |
6 | 13 | 72.28 | 18 | 15.41 | 374 | 104 | 2.67 / 31.08 | 2 | 2 |
7 | 8 | 0.08 | 165 | 15.38 | 265 | 672 | 3.34 / 31.76 | 2 | 4 |
8 | 14 | 0.08 | 30 | 15.36 | 264 | 122 | 3.46 / 31.88 | 2 | 6 |
Average= | 3.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.16 | 27 | 15.31 | 403 | 167 | 0.17 / 24.90 | 3 | 3 |
2 | 7 | 2002.52 | 30 | 15.11 | 2893 | 1311 | 1.48 / 26.21 | 2 | 2 |
3 | 13 | 1572.12 | 18 | 15.16 | 2382 | 650 | 2.13 / 26.86 | 2 | 2 |
4 | 13 | 980.92 | 18 | 15.24 | 1626 | 446 | 2.57 / 27.31 | 2 | 2 |
5 | 13 | 412.32 | 18 | 15.35 | 866 | 239 | 2.81 / 27.54 | 2 | 2 |
6 | 13 | 128.00 | 18 | 15.38 | 454 | 126 | 2.94 / 27.67 | 2 | 2 |
7 | 13 | 28.96 | 18 | 15.39 | 310 | 86 | 3.02 / 27.76 | 2 | 2 |
8 | 8 | 0.16 | 165 | 15.35 | 260 | 659 | 3.68 / 28.41 | 2 | 6 |
Average= | 3.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 27 | 15.33 | 399 | 165 | 0.17 / 21.34 | 3 | 3 |
2 | 3 | 1020.24 | 1 | 15.41 | 1735 | 27 | 0.19 / 21.36 | 2 | 2 |
3 | 7 | 1902.84 | 36 | 15.10 | 2782 | 1512 | 1.70 / 22.88 | 2 | 2 |
4 | 13 | 1327.80 | 18 | 15.18 | 2069 | 565 | 2.27 / 23.44 | 2 | 2 |
5 | 13 | 778.24 | 18 | 15.29 | 1358 | 374 | 2.64 / 23.81 | 2 | 2 |
6 | 13 | 213.48 | 18 | 15.39 | 578 | 160 | 2.80 / 23.97 | 2 | 2 |
7 | 13 | 59.88 | 18 | 15.38 | 351 | 97 | 2.90 / 24.07 | 2 | 2 |
8 | 8 | 0.04 | 165 | 15.36 | 260 | 659 | 3.56 / 24.73 | 2 | 5 |
Average= | 3.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.12 | 26 | 15.32 | 417 | 166 | 0.17 / 17.70 | 3 | 3 |
2 | 3 | 1032.16 | 1 | 15.42 | 1753 | 27 | 0.19 / 17.73 | 2 | 2 |
3 | 7 | 2003.44 | 38 | 15.05 | 2899 | 1658 | 1.85 / 19.39 | 2 | 2 |
4 | 13 | 1268.68 | 18 | 15.17 | 1998 | 546 | 2.40 / 19.93 | 2 | 2 |
5 | 13 | 712.28 | 18 | 15.27 | 1273 | 350 | 2.75 / 20.28 | 2 | 2 |
6 | 13 | 168.88 | 18 | 15.40 | 507 | 141 | 2.89 / 20.42 | 2 | 2 |
7 | 13 | 53.08 | 18 | 15.39 | 338 | 94 | 2.98 / 20.52 | 2 | 2 |
8 | 8 | 0.12 | 165 | 15.36 | 258 | 654 | 3.63 / 21.17 | 2 | 5 |
Average= | 3.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.48 | 26 | 15.31 | 419 | 167 | 0.17 / 14.08 | 2 | 3 |
2 | 7 | 2002.92 | 38 | 15.05 | 2890 | 1653 | 1.82 / 15.73 | 2 | 2 |
3 | 13 | 1402.36 | 18 | 15.15 | 2158 | 588 | 2.41 / 16.32 | 2 | 2 |
4 | 13 | 684.24 | 18 | 15.28 | 1229 | 338 | 2.75 / 16.66 | 2 | 2 |
5 | 13 | 136.04 | 18 | 15.38 | 461 | 128 | 2.87 / 16.79 | 2 | 2 |
6 | 13 | 35.24 | 18 | 15.39 | 317 | 88 | 2.96 / 16.87 | 2 | 2 |
7 | 8 | 0.00 | 165 | 15.35 | 262 | 664 | 3.63 / 17.54 | 2 | 7 |
Average= | 2.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.68 | 26 | 15.32 | 419 | 167 | 0.17 / 10.97 | 2 | 3 |
2 | 7 | 1523.08 | 38 | 15.21 | 2289 | 1323 | 1.49 / 12.29 | 2 | 2 |
3 | 13 | 1137.04 | 18 | 15.26 | 1811 | 497 | 1.99 / 12.79 | 2 | 2 |
4 | 13 | 688.24 | 18 | 15.32 | 1235 | 341 | 2.33 / 13.13 | 2 | 2 |
5 | 13 | 120.28 | 18 | 15.40 | 438 | 121 | 2.45 / 13.25 | 2 | 2 |
6 | 8 | 0.08 | 165 | 15.37 | 261 | 662 | 3.11 / 13.91 | 2 | 3 |
Average= | 2.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.72 | 26 | 15.33 | 416 | 166 | 0.17 / 7.78 | 3 | 3 |
2 | 3 | 1021.56 | 1 | 15.40 | 1740 | 27 | 0.19 / 7.80 | 2 | 2 |
3 | 7 | 1520.00 | 39 | 15.19 | 2272 | 1346 | 1.54 / 9.15 | 2 | 2 |
4 | 13 | 1258.80 | 18 | 15.23 | 1962 | 538 | 2.08 / 9.69 | 2 | 2 |
5 | 13 | 666.12 | 18 | 15.30 | 1202 | 331 | 2.41 / 10.02 | 2 | 2 |
6 | 13 | 119.80 | 18 | 15.39 | 440 | 122 | 2.53 / 10.14 | 2 | 2 |
7 | 8 | 0.16 | 165 | 15.37 | 260 | 659 | 3.19 / 10.80 | 2 | 5 |
Average= | 2.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.44 | 28 | 15.34 | 415 | 178 | 0.18 / 4.23 | 2 | 3 |
2 | 3 | 948.08 | -1 | 15.67 | 0 | 0 | 0.00 / 4.23 | 2 | 3 |
3 | 7 | 1506.32 | 74 | 15.12 | 2247 | 2514 | 2.69 / 6.74 | 2 | 2 |
4 | 13 | 137.92 | 18 | 15.42 | 459 | 127 | 2.82 / 6.87 | 2 | 2 |
5 | 13 | 35.96 | 18 | 15.42 | 313 | 87 | 2.91 / 6.96 | 2 | 2 |
6 | 8 | 0.12 | 165 | 15.39 | 258 | 655 | 3.56 / 7.61 | 2 | 4 |
Average= | 2.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.08 | 24 | 15.51 | 389 | 145 | 0.14 / 1.51 | 3 | 3 |
2 | 3 | 1062.32 | 2 | 15.40 | 1772 | 55 | 0.20 / 1.56 | 2 | 2 |
3 | 7 | 1002.00 | 74 | 15.25 | 1604 | 1810 | 2.01 / 3.37 | 2 | 2 |
4 | 8 | -0.08 | 165 | 15.39 | 266 | 675 | 2.68 / 4.05 | 2 | 4 |
Average= | 2.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 84.08 | 24 | 15.65 | 349 | 131 | 0.13 / 0.13 | 3 | 3 |
2 | 7 | 98.52 | 74 | 15.62 | 362 | 418 | 0.55 / 0.55 | 3 | 3 |
3 | 8 | 0.20 | 240 | 15.59 | 218 | 816 | 1.37 / 1.37 | 3 | 6 |
Average= | 1.37 (KJ/cycle) |