SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 28 | 10.99 | 420 | 129 | 0.13 / 1442.10 | 2 | 2 |
2 | 10 | 1004.88 | 3 | 8.66 | 1810 | 47 | 0.18 / 1442.14 | 1 | 1 |
3 | 3 | 1090.12 | 2 | 8.22 | 1929 | 32 | 0.21 / 1442.18 | 1 | 1 |
4 | 3 | 1059.76 | 2 | 8.37 | 1888 | 32 | 0.24 / 1442.21 | 1 | 1 |
5 | 12 | 1158.76 | 124 | 6.68 | 1995 | 1652 | 1.89 / 1443.86 | 1 | 1 |
6 | 7 | 1154.68 | 24 | 7.03 | 2033 | 343 | 2.24 / 1444.20 | 1 | 1 |
7 | 13 | 1055.72 | 52 | 7.43 | 1887 | 729 | 2.96 / 1444.93 | 1 | 1 |
8 | 13 | 127.88 | 52 | 10.64 | 472 | 261 | 3.23 / 1445.19 | 1 | 2 |
9 | 8 | -0.08 | 160 | 11.04 | 264 | 466 | 3.69 / 1445.66 | 2 | 2 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 32 | 11.25 | 431 | 155 | 0.16 / 1438.83 | 2 | 2 |
2 | 12 | 1115.36 | 124 | 7.00 | 1940 | 1684 | 1.84 / 1440.51 | 1 | 1 |
3 | 7 | 1110.72 | 24 | 7.24 | 1966 | 342 | 2.18 / 1440.85 | 1 | 1 |
4 | 13 | 708.04 | 52 | 8.93 | 1378 | 640 | 2.82 / 1441.49 | 1 | 1 |
5 | 8 | -0.04 | 160 | 11.15 | 266 | 475 | 3.30 / 1441.97 | 2 | 2 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.60 | 26 | 11.52 | 426 | 128 | 0.13 / 1435.21 | 2 | 2 |
2 | 10 | 1039.48 | 3 | 9.91 | 1879 | 56 | 0.18 / 1435.27 | 1 | 1 |
3 | 3 | 1080.44 | 2 | 9.67 | 1962 | 38 | 0.22 / 1435.31 | 1 | 1 |
4 | 3 | 1040.60 | 1 | 9.72 | 1906 | 19 | 0.24 / 1435.32 | 1 | 1 |
5 | 12 | 1101.28 | 124 | 7.43 | 1946 | 1793 | 2.03 / 1437.12 | 1 | 1 |
6 | 7 | 1095.20 | 24 | 7.75 | 1959 | 364 | 2.40 / 1437.48 | 1 | 1 |
7 | 13 | 759.04 | 52 | 9.01 | 1474 | 691 | 3.09 / 1438.17 | 1 | 1 |
8 | 8 | 0.16 | 160 | 11.39 | 275 | 501 | 3.59 / 1438.67 | 2 | 2 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 26 | 11.93 | 428 | 133 | 0.13 / 1427.51 | 2 | 2 |
2 | 10 | 1011.04 | 4 | 10.26 | 1839 | 75 | 0.21 / 1427.58 | 1 | 1 |
3 | 3 | 1079.40 | 2 | 9.92 | 1945 | 39 | 0.25 / 1427.62 | 1 | 1 |
4 | 3 | 1041.84 | 1 | 10.04 | 1897 | 19 | 0.27 / 1427.64 | 1 | 1 |
5 | 12 | 1998.12 | 124 | 6.02 | 2726 | 2035 | 2.30 / 1429.68 | 1 | 1 |
6 | 7 | 1995.40 | 24 | 5.71 | 2543 | 348 | 2.65 / 1430.02 | 1 | 1 |
7 | 13 | 1948.40 | 52 | 6.50 | 3178 | 1074 | 3.72 / 1431.10 | 1 | 1 |
8 | 13 | 1876.64 | 52 | 6.79 | 3100 | 1095 | 4.82 / 1432.19 | 1 | 1 |
9 | 13 | 1679.44 | 52 | 7.45 | 2829 | 1096 | 5.91 / 1433.29 | 1 | 1 |
10 | 13 | 1140.04 | 52 | 8.86 | 2053 | 946 | 6.86 / 1434.23 | 1 | 1 |
11 | 13 | 203.04 | 52 | 11.14 | 598 | 346 | 7.21 / 1434.58 | 1 | 2 |
12 | 8 | -0.04 | 160 | 11.57 | 272 | 504 | 7.71 / 1435.08 | 2 | 2 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.40 | 25 | 12.73 | 447 | 142 | 0.14 / 1423.34 | 2 | 2 |
2 | 10 | 1020.00 | 3 | 11.55 | 1870 | 65 | 0.21 / 1423.40 | 1 | 2 |
3 | 3 | 1024.20 | 1 | 11.07 | 1890 | 21 | 0.23 / 1423.42 | 1 | 1 |
4 | 12 | 1144.56 | 124 | 5.84 | 1867 | 1352 | 1.58 / 1424.78 | 1 | 1 |
5 | 7 | 1146.92 | 24 | 8.45 | 2027 | 411 | 1.99 / 1425.19 | 1 | 2 |
6 | 13 | 1107.08 | 52 | 8.31 | 1967 | 850 | 2.84 / 1426.04 | 1 | 1 |
7 | 13 | 906.00 | 52 | 9.17 | 1694 | 808 | 3.65 / 1426.84 | 1 | 1 |
8 | 8 | 0.04 | 160 | 12.04 | 275 | 530 | 4.18 / 1427.37 | 2 | 2 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 26 | 13.53 | 457 | 161 | 0.16 / 1418.76 | 2 | 2 |
2 | 12 | 1129.36 | 124 | 5.41 | 1627 | 1091 | 1.25 / 1419.85 | 1 | 1 |
3 | 7 | 1133.60 | 24 | 8.75 | 2015 | 423 | 1.68 / 1420.28 | 1 | 1 |
4 | 13 | 1186.56 | 52 | 7.45 | 2049 | 794 | 2.47 / 1421.07 | 1 | 1 |
5 | 13 | 1127.20 | 52 | 8.27 | 1988 | 855 | 3.32 / 1421.92 | 1 | 1 |
6 | 13 | 607.32 | 52 | 10.74 | 1238 | 691 | 4.02 / 1422.62 | 1 | 2 |
7 | 8 | 0.04 | 160 | 12.64 | 287 | 580 | 4.60 / 1423.20 | 2 | 3 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.00 | 26 | 13.87 | 465 | 168 | 0.17 / 1415.07 | 2 | 2 |
2 | 12 | 1113.08 | 124 | 6.47 | 1908 | 1531 | 1.70 / 1416.60 | 1 | 1 |
3 | 7 | 1108.72 | 24 | 9.83 | 1994 | 470 | 2.17 / 1417.07 | 1 | 1 |
4 | 13 | 894.36 | 52 | 10.38 | 1674 | 904 | 3.07 / 1417.98 | 1 | 1 |
5 | 8 | -0.16 | 160 | 13.50 | 289 | 624 | 3.70 / 1418.60 | 2 | 4 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 25 | 13.94 | 473 | 165 | 0.16 / 1408.30 | 2 | 2 |
2 | 12 | 1996.32 | 124 | 6.73 | 3068 | 2560 | 2.73 / 1410.86 | 1 | 1 |
3 | 7 | 1991.84 | 24 | 8.81 | 3352 | 709 | 3.43 / 1411.57 | 1 | 1 |
4 | 13 | 1893.48 | 52 | 8.94 | 3183 | 1480 | 4.91 / 1413.05 | 1 | 1 |
5 | 13 | 1131.00 | 52 | 10.91 | 2081 | 1181 | 6.09 / 1414.23 | 1 | 1 |
6 | 8 | 0.32 | 160 | 13.85 | 303 | 671 | 6.77 / 1414.90 | 2 | 2 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.12 | 26 | 13.94 | 471 | 171 | 0.17 / 1403.46 | 2 | 2 |
2 | 12 | 1104.96 | 124 | 5.39 | 1568 | 1048 | 1.22 / 1404.51 | 1 | 1 |
3 | 7 | 1109.28 | 24 | 9.08 | 1984 | 432 | 1.65 / 1404.94 | 1 | 2 |
4 | 13 | 1163.04 | 52 | 8.19 | 2028 | 864 | 2.51 / 1405.80 | 1 | 1 |
5 | 13 | 1094.88 | 52 | 9.07 | 1966 | 927 | 3.44 / 1406.73 | 1 | 2 |
6 | 13 | 542.60 | 52 | 12.31 | 1151 | 737 | 4.18 / 1407.47 | 1 | 2 |
7 | 8 | -0.12 | 160 | 13.93 | 301 | 671 | 4.85 / 1408.14 | 2 | 10 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 26 | 14.02 | 472 | 172 | 0.17 / 1398.56 | 2 | 2 |
2 | 12 | 1116.40 | 124 | 5.38 | 1483 | 989 | 1.16 / 1399.55 | 1 | 2 |
3 | 7 | 1120.72 | 24 | 8.54 | 1984 | 407 | 1.57 / 1399.95 | 2 | 2 |
4 | 13 | 1176.20 | 52 | 7.78 | 2031 | 822 | 2.39 / 1400.77 | 1 | 2 |
5 | 13 | 1120.36 | 52 | 8.98 | 1995 | 932 | 3.32 / 1401.71 | 1 | 2 |
6 | 13 | 795.72 | 52 | 11.34 | 1541 | 909 | 4.23 / 1402.61 | 1 | 2 |
7 | 8 | 0.28 | 160 | 13.98 | 301 | 673 | 4.90 / 1403.29 | 2 | 2 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.00 | 25 | 14.05 | 479 | 168 | 0.17 / 1394.18 | 2 | 2 |
2 | 3 | 1020.76 | 1 | 11.29 | 1881 | 21 | 0.19 / 1394.20 | 1 | 1 |
3 | 12 | 1131.32 | 124 | 5.77 | 1912 | 1368 | 1.56 / 1395.57 | 1 | 1 |
4 | 7 | 1132.88 | 24 | 9.71 | 2022 | 471 | 2.03 / 1396.04 | 1 | 2 |
5 | 13 | 1072.72 | 52 | 9.98 | 1940 | 1007 | 3.04 / 1397.05 | 1 | 2 |
6 | 13 | 438.56 | 52 | 13.02 | 984 | 666 | 3.70 / 1397.71 | 1 | 2 |
7 | 8 | 0.04 | 160 | 14.10 | 297 | 670 | 4.37 / 1398.38 | 2 | 3 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.52 | 26 | 14.01 | 473 | 172 | 0.17 / 1387.21 | 2 | 2 |
2 | 12 | 1996.96 | 124 | 6.64 | 3115 | 2565 | 2.74 / 1389.77 | 1 | 1 |
3 | 7 | 1993.24 | 24 | 9.24 | 3362 | 746 | 3.48 / 1390.52 | 1 | 1 |
4 | 13 | 1896.92 | 52 | 9.35 | 3197 | 1554 | 5.04 / 1392.07 | 1 | 1 |
5 | 13 | 1114.28 | 52 | 11.72 | 2059 | 1255 | 6.29 / 1393.33 | 1 | 1 |
6 | 8 | 0.04 | 160 | 14.12 | 303 | 685 | 6.98 / 1394.01 | 2 | 4 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.12 | 25 | 14.02 | 475 | 166 | 0.17 / 1382.38 | 2 | 2 |
2 | 3 | 1021.56 | 1 | 10.64 | 1893 | 20 | 0.19 / 1382.40 | 1 | 1 |
3 | 12 | 1137.16 | 124 | 5.42 | 1663 | 1118 | 1.30 / 1383.52 | 1 | 2 |
4 | 7 | 1141.24 | 24 | 9.28 | 2032 | 453 | 1.76 / 1383.97 | 2 | 2 |
5 | 13 | 1196.92 | 52 | 9.21 | 2101 | 1006 | 2.76 / 1384.98 | 1 | 2 |
6 | 13 | 1123.68 | 52 | 10.06 | 2021 | 1057 | 3.82 / 1386.04 | 1 | 2 |
7 | 13 | 114.48 | 52 | 13.86 | 477 | 344 | 4.16 / 1386.38 | 1 | 2 |
8 | 8 | 0.12 | 160 | 14.16 | 289 | 655 | 4.82 / 1387.04 | 2 | 2 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 25 | 14.04 | 484 | 170 | 0.17 / 1377.52 | 2 | 2 |
2 | 12 | 1113.72 | 124 | 5.42 | 1678 | 1128 | 1.30 / 1378.65 | 1 | 2 |
3 | 7 | 1117.96 | 24 | 9.25 | 1995 | 443 | 1.74 / 1379.09 | 2 | 2 |
4 | 13 | 1180.20 | 52 | 9.22 | 2073 | 994 | 2.73 / 1380.08 | 1 | 2 |
5 | 13 | 1106.00 | 52 | 10.08 | 1986 | 1041 | 3.78 / 1381.13 | 1 | 2 |
6 | 13 | 186.96 | 52 | 13.68 | 595 | 423 | 4.20 / 1381.55 | 1 | 2 |
7 | 8 | -0.04 | 160 | 14.14 | 296 | 670 | 4.87 / 1382.22 | 2 | 2 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 26 | 14.11 | 477 | 175 | 0.17 / 1373.47 | 2 | 2 |
2 | 3 | 950.24 | -1 | 15.03 | 0 | 0 | 0.00 / 1373.47 | 2 | 2 |
3 | 12 | 1132.76 | 124 | 5.96 | 1916 | 1416 | 1.59 / 1374.88 | 1 | 2 |
4 | 7 | 1130.04 | 24 | 9.81 | 2005 | 472 | 2.06 / 1375.36 | 2 | 2 |
5 | 13 | 1043.76 | 52 | 10.58 | 1908 | 1050 | 3.11 / 1376.41 | 1 | 2 |
6 | 13 | 38.36 | 52 | 14.04 | 354 | 258 | 3.37 / 1376.66 | 1 | 2 |
7 | 8 | 0.04 | 160 | 14.15 | 303 | 686 | 4.06 / 1377.35 | 2 | 3 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 26 | 14.02 | 492 | 179 | 0.18 / 1366.55 | 2 | 2 |
2 | 12 | 2001.40 | 124 | 7.00 | 3182 | 2762 | 2.94 / 1369.32 | 1 | 1 |
3 | 7 | 1997.04 | 25 | 9.50 | 3376 | 802 | 3.74 / 1370.12 | 1 | 1 |
4 | 13 | 1799.76 | 52 | 10.42 | 3069 | 1663 | 5.41 / 1371.78 | 1 | 1 |
5 | 13 | 558.16 | 52 | 13.11 | 1200 | 818 | 6.22 / 1372.60 | 1 | 2 |
6 | 8 | 0.16 | 160 | 14.17 | 306 | 694 | 6.92 / 1373.29 | 2 | 3 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.12 | 26 | 14.03 | 457 | 167 | 0.17 / 1361.83 | 2 | 2 |
2 | 3 | 949.88 | -1 | 15.00 | 0 | 0 | 0.00 / 1361.83 | 2 | 2 |
3 | 12 | 1137.52 | 124 | 5.59 | 1855 | 1286 | 1.45 / 1363.11 | 1 | 2 |
4 | 7 | 1141.00 | 24 | 9.78 | 2031 | 477 | 1.93 / 1363.59 | 2 | 2 |
5 | 13 | 1127.96 | 52 | 10.47 | 2036 | 1108 | 3.04 / 1364.70 | 1 | 2 |
6 | 13 | 825.88 | 52 | 11.95 | 1595 | 991 | 4.03 / 1365.69 | 1 | 2 |
7 | 8 | 0.56 | 160 | 14.12 | 304 | 687 | 4.72 / 1366.37 | 2 | 2 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 25 | 13.99 | 481 | 168 | 0.17 / 1356.71 | 2 | 2 |
2 | 3 | 1025.48 | 1 | 10.90 | 1878 | 20 | 0.19 / 1356.73 | 1 | 1 |
3 | 12 | 1136.60 | 124 | 5.44 | 1705 | 1150 | 1.34 / 1357.88 | 1 | 1 |
4 | 7 | 1141.40 | 24 | 9.37 | 2043 | 459 | 1.80 / 1358.34 | 1 | 1 |
5 | 13 | 1191.52 | 52 | 9.61 | 2104 | 1051 | 2.85 / 1359.39 | 1 | 1 |
6 | 13 | 1113.00 | 52 | 10.38 | 2011 | 1085 | 3.94 / 1360.47 | 1 | 1 |
7 | 13 | 73.56 | 52 | 13.94 | 417 | 302 | 4.24 / 1360.78 | 1 | 2 |
8 | 8 | -0.28 | 160 | 14.15 | 296 | 670 | 4.91 / 1361.45 | 2 | 3 |
9 | 14 | -0.28 | 50 | 14.17 | 301 | 213 | 5.12 / 1361.66 | 2 | 6 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.24 | 25 | 14.05 | 492 | 173 | 0.17 / 1352.89 | 1 | 2 |
2 | 12 | 1108.96 | 124 | 6.14 | 1887 | 1437 | 1.61 / 1354.33 | 1 | 1 |
3 | 7 | 1105.68 | 24 | 9.94 | 1968 | 469 | 2.08 / 1354.80 | 1 | 2 |
4 | 13 | 1011.76 | 52 | 10.86 | 1866 | 1054 | 3.13 / 1355.85 | 1 | 2 |
5 | 8 | -0.04 | 160 | 14.12 | 303 | 685 | 3.82 / 1356.54 | 2 | 2 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.44 | 25 | 13.97 | 486 | 170 | 0.17 / 1345.88 | 2 | 2 |
2 | 12 | 1996.48 | 124 | 6.85 | 3161 | 2685 | 2.85 / 1348.57 | 1 | 1 |
3 | 7 | 1992.04 | 24 | 9.57 | 3361 | 772 | 3.63 / 1349.34 | 1 | 1 |
4 | 13 | 1791.20 | 52 | 10.61 | 3062 | 1689 | 5.32 / 1351.03 | 1 | 1 |
5 | 13 | 751.64 | 52 | 12.79 | 1503 | 1000 | 6.32 / 1352.03 | 1 | 2 |
6 | 8 | 0.32 | 160 | 14.17 | 306 | 694 | 7.01 / 1352.72 | 2 | 3 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.12 | 26 | 14.03 | 473 | 173 | 0.17 / 1341.32 | 2 | 2 |
2 | 12 | 1119.76 | 124 | 5.66 | 1857 | 1303 | 1.48 / 1342.62 | 1 | 1 |
3 | 7 | 1122.56 | 24 | 9.95 | 2013 | 481 | 1.96 / 1343.10 | 1 | 2 |
4 | 13 | 1089.40 | 52 | 10.82 | 1983 | 1116 | 3.07 / 1344.22 | 1 | 1 |
5 | 13 | 566.48 | 52 | 12.87 | 1198 | 802 | 3.87 / 1345.02 | 1 | 2 |
6 | 8 | 0.00 | 160 | 14.13 | 306 | 692 | 4.57 / 1345.71 | 2 | 3 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.04 | 25 | 13.95 | 482 | 168 | 0.17 / 1336.35 | 2 | 2 |
2 | 12 | 1131.00 | 124 | 5.44 | 1774 | 1197 | 1.36 / 1337.55 | 1 | 1 |
3 | 7 | 1134.80 | 24 | 9.63 | 2021 | 467 | 1.83 / 1338.02 | 1 | 2 |
4 | 13 | 1182.48 | 52 | 9.99 | 2099 | 1090 | 2.92 / 1339.11 | 1 | 1 |
5 | 13 | 1102.24 | 52 | 10.65 | 2003 | 1109 | 4.03 / 1340.22 | 1 | 2 |
6 | 13 | 26.12 | 52 | 14.06 | 340 | 249 | 4.28 / 1340.47 | 1 | 2 |
7 | 8 | -0.04 | 160 | 14.16 | 300 | 680 | 4.96 / 1341.15 | 2 | 2 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 26 | 14.07 | 482 | 176 | 0.18 / 1332.37 | 2 | 2 |
2 | 3 | 966.20 | -1 | 15.03 | 0 | 0 | 0.00 / 1332.37 | 2 | 2 |
3 | 3 | 1031.16 | 1 | 11.32 | 1885 | 21 | 0.20 / 1332.39 | 1 | 1 |
4 | 12 | 1138.12 | 124 | 6.33 | 1933 | 1517 | 1.71 / 1333.91 | 1 | 1 |
5 | 7 | 1134.76 | 24 | 10.01 | 2049 | 492 | 2.21 / 1334.40 | 1 | 2 |
6 | 13 | 1034.64 | 52 | 11.06 | 1902 | 1094 | 3.30 / 1335.50 | 1 | 2 |
7 | 8 | 0.08 | 160 | 14.14 | 304 | 688 | 3.99 / 1336.19 | 2 | 2 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.64 | 26 | 14.00 | 476 | 173 | 0.17 / 1325.41 | 2 | 2 |
2 | 12 | 1994.84 | 124 | 6.83 | 3196 | 2707 | 2.88 / 1328.11 | 1 | 1 |
3 | 7 | 1990.56 | 24 | 9.80 | 3367 | 792 | 3.67 / 1328.90 | 1 | 1 |
4 | 13 | 1696.16 | 52 | 11.01 | 2927 | 1676 | 5.35 / 1330.58 | 1 | 1 |
5 | 13 | 654.68 | 52 | 13.05 | 1353 | 918 | 6.27 / 1331.50 | 1 | 2 |
6 | 8 | 0.16 | 160 | 14.18 | 308 | 699 | 6.96 / 1332.20 | 2 | 4 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 26 | 14.01 | 461 | 168 | 0.17 / 1320.81 | 1 | 2 |
2 | 3 | 968.12 | -1 | 15.00 | 0 | 0 | 0.00 / 1320.81 | 1 | 2 |
3 | 3 | 1029.72 | 1 | 11.03 | 1887 | 21 | 0.19 / 1320.84 | 1 | 1 |
4 | 12 | 1146.12 | 124 | 5.72 | 1900 | 1348 | 1.54 / 1322.18 | 1 | 2 |
5 | 7 | 1148.92 | 24 | 10.09 | 2048 | 496 | 2.03 / 1322.68 | 2 | 2 |
6 | 13 | 1102.12 | 52 | 11.03 | 2008 | 1152 | 3.18 / 1323.83 | 1 | 2 |
7 | 13 | 443.52 | 52 | 13.26 | 1013 | 698 | 3.88 / 1324.53 | 1 | 2 |
8 | 8 | -0.16 | 160 | 14.14 | 311 | 704 | 4.59 / 1325.23 | 2 | 5 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 26 | 14.01 | 469 | 171 | 0.17 / 1315.68 | 2 | 2 |
2 | 12 | 1115.00 | 124 | 5.46 | 1875 | 1269 | 1.44 / 1316.95 | 1 | 1 |
3 | 7 | 1119.16 | 24 | 9.89 | 2007 | 476 | 1.92 / 1317.43 | 1 | 1 |
4 | 13 | 1169.36 | 52 | 10.39 | 2085 | 1126 | 3.04 / 1318.56 | 1 | 1 |
5 | 13 | 1082.60 | 52 | 10.94 | 1978 | 1125 | 4.17 / 1319.68 | 1 | 2 |
6 | 13 | 42.64 | 52 | 14.02 | 375 | 273 | 4.44 / 1319.95 | 1 | 2 |
7 | 8 | 0.24 | 160 | 14.14 | 306 | 692 | 5.13 / 1320.65 | 2 | 4 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 26 | 14.00 | 472 | 172 | 0.17 / 1311.65 | 2 | 2 |
2 | 3 | 973.36 | -1 | 15.03 | 0 | 0 | 0.00 / 1311.65 | 2 | 2 |
3 | 3 | 1030.96 | 1 | 11.27 | 1890 | 21 | 0.19 / 1311.67 | 1 | 1 |
4 | 12 | 1144.60 | 124 | 6.37 | 1948 | 1539 | 1.73 / 1313.21 | 1 | 1 |
5 | 7 | 1140.56 | 24 | 10.09 | 2054 | 497 | 2.23 / 1313.71 | 1 | 2 |
6 | 13 | 1041.88 | 52 | 11.13 | 1917 | 1109 | 3.34 / 1314.82 | 1 | 2 |
7 | 8 | 0.08 | 160 | 14.14 | 308 | 697 | 4.04 / 1315.51 | 2 | 2 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.60 | 26 | 14.00 | 462 | 168 | 0.17 / 1304.49 | 2 | 2 |
2 | 3 | 954.16 | -1 | 15.01 | 0 | 0 | 0.00 / 1304.49 | 2 | 2 |
3 | 12 | 1997.20 | 124 | 6.68 | 3174 | 2629 | 2.80 / 1307.12 | 1 | 1 |
4 | 7 | 1993.40 | 24 | 9.88 | 3369 | 799 | 3.60 / 1307.92 | 1 | 1 |
5 | 13 | 1898.12 | 52 | 10.55 | 3218 | 1765 | 5.36 / 1309.68 | 1 | 1 |
6 | 13 | 862.64 | 52 | 12.67 | 1684 | 1109 | 6.47 / 1310.79 | 1 | 2 |
7 | 8 | -0.44 | 160 | 14.19 | 302 | 686 | 7.16 / 1311.48 | 2 | 3 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.72 | 25 | 13.99 | 457 | 160 | 0.16 / 1300.37 | 2 | 2 |
2 | 3 | 1030.60 | 1 | 11.23 | 1884 | 21 | 0.18 / 1300.39 | 1 | 1 |
3 | 12 | 1130.68 | 124 | 5.93 | 1898 | 1396 | 1.58 / 1301.79 | 1 | 2 |
4 | 7 | 1128.28 | 24 | 10.17 | 2005 | 489 | 2.07 / 1302.28 | 2 | 2 |
5 | 13 | 1036.84 | 52 | 11.28 | 1909 | 1120 | 3.19 / 1303.39 | 1 | 2 |
6 | 13 | 17.84 | 52 | 14.08 | 330 | 242 | 3.43 / 1303.64 | 1 | 2 |
7 | 8 | 0.00 | 160 | 14.15 | 302 | 684 | 4.11 / 1304.32 | 2 | 5 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.32 | 26 | 13.97 | 481 | 175 | 0.17 / 1295.38 | 2 | 2 |
2 | 3 | 972.64 | -1 | 15.02 | 0 | 0 | 0.00 / 1295.38 | 2 | 2 |
3 | 3 | 1033.72 | 1 | 10.94 | 1914 | 21 | 0.20 / 1295.40 | 1 | 1 |
4 | 12 | 1152.96 | 124 | 5.50 | 1949 | 1329 | 1.52 / 1296.73 | 1 | 1 |
5 | 7 | 1157.08 | 24 | 9.90 | 2068 | 491 | 2.02 / 1297.23 | 1 | 2 |
6 | 13 | 1202.56 | 52 | 10.43 | 2134 | 1157 | 3.17 / 1298.38 | 1 | 1 |
7 | 13 | 1112.72 | 52 | 10.99 | 2023 | 1156 | 4.33 / 1299.54 | 1 | 1 |
8 | 8 | 0.04 | 160 | 14.15 | 296 | 670 | 5.00 / 1300.21 | 2 | 3 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 26 | 14.02 | 459 | 167 | 0.17 / 1291.45 | 2 | 2 |
2 | 3 | 972.32 | -1 | 15.02 | 0 | 0 | 0.00 / 1291.45 | 2 | 2 |
3 | 3 | 1031.00 | 1 | 11.08 | 1909 | 21 | 0.19 / 1291.47 | 1 | 1 |
4 | 12 | 1135.44 | 124 | 6.70 | 1937 | 1609 | 1.80 / 1293.08 | 1 | 1 |
5 | 7 | 1131.40 | 24 | 10.18 | 2016 | 493 | 2.29 / 1293.57 | 1 | 1 |
6 | 13 | 716.80 | 52 | 12.54 | 1434 | 935 | 3.23 / 1294.51 | 1 | 2 |
7 | 8 | 0.04 | 160 | 14.12 | 310 | 700 | 3.93 / 1295.21 | 2 | 6 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 26 | 13.95 | 467 | 169 | 0.17 / 1284.21 | 2 | 2 |
2 | 3 | 964.44 | -1 | 15.01 | 0 | 0 | 0.00 / 1284.21 | 2 | 2 |
3 | 3 | 1032.56 | 1 | 10.84 | 1901 | 21 | 0.19 / 1284.24 | 1 | 1 |
4 | 12 | 1997.84 | 124 | 6.55 | 3170 | 2575 | 2.76 / 1286.81 | 1 | 1 |
5 | 7 | 1994.00 | 24 | 9.91 | 3385 | 805 | 3.57 / 1287.61 | 1 | 1 |
6 | 13 | 1901.84 | 52 | 10.61 | 3221 | 1777 | 5.35 / 1289.39 | 1 | 1 |
7 | 13 | 980.84 | 52 | 12.47 | 1864 | 1209 | 6.56 / 1290.60 | 1 | 2 |
8 | 8 | 0.00 | 160 | 14.18 | 301 | 683 | 7.24 / 1291.28 | 1 | 3 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 25 | 14.00 | 454 | 159 | 0.16 / 1279.85 | 2 | 2 |
2 | 12 | 1123.64 | 124 | 5.67 | 1881 | 1322 | 1.48 / 1281.17 | 1 | 1 |
3 | 7 | 1126.08 | 24 | 10.07 | 2027 | 490 | 1.97 / 1281.66 | 1 | 1 |
4 | 13 | 1077.56 | 52 | 10.97 | 1977 | 1128 | 3.10 / 1282.79 | 1 | 1 |
5 | 13 | 322.24 | 52 | 13.49 | 823 | 577 | 3.68 / 1283.36 | 1 | 2 |
6 | 8 | 0.08 | 160 | 14.13 | 301 | 681 | 4.36 / 1284.05 | 2 | 4 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 25 | 13.95 | 472 | 165 | 0.16 / 1275.67 | 2 | 2 |
2 | 3 | 963.24 | -1 | 15.02 | 0 | 0 | 0.00 / 1275.67 | 2 | 2 |
3 | 3 | 1040.32 | 1 | 10.91 | 1912 | 21 | 0.19 / 1275.69 | 1 | 1 |
4 | 12 | 1137.76 | 124 | 5.87 | 1911 | 1391 | 1.58 / 1277.08 | 1 | 1 |
5 | 7 | 1135.80 | 24 | 9.92 | 2061 | 491 | 2.07 / 1277.57 | 1 | 1 |
6 | 13 | 1043.64 | 52 | 10.98 | 1931 | 1103 | 3.17 / 1278.67 | 1 | 1 |
7 | 13 | 88.76 | 52 | 13.93 | 454 | 329 | 3.50 / 1279.00 | 1 | 2 |
8 | 8 | -0.16 | 160 | 14.12 | 304 | 687 | 4.19 / 1279.69 | 2 | 5 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 26 | 14.04 | 474 | 173 | 0.17 / 1271.99 | 2 | 2 |
2 | 12 | 1089.88 | 124 | 6.95 | 1887 | 1626 | 1.80 / 1273.62 | 1 | 1 |
3 | 7 | 1085.24 | 24 | 10.26 | 1966 | 484 | 2.28 / 1274.10 | 1 | 1 |
4 | 13 | 461.20 | 52 | 13.19 | 1042 | 715 | 3.00 / 1274.82 | 1 | 2 |
5 | 8 | 0.00 | 160 | 14.11 | 304 | 686 | 3.68 / 1275.50 | 2 | 3 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 26 | 13.95 | 478 | 173 | 0.17 / 1264.69 | 2 | 2 |
2 | 3 | 970.60 | -1 | 15.02 | 0 | 0 | 0.00 / 1264.69 | 2 | 2 |
3 | 3 | 1029.96 | 1 | 10.71 | 1903 | 20 | 0.19 / 1264.71 | 1 | 1 |
4 | 12 | 1999.76 | 124 | 6.44 | 3176 | 2536 | 2.73 / 1267.24 | 1 | 1 |
5 | 7 | 1996.08 | 24 | 9.89 | 3401 | 807 | 3.54 / 1268.05 | 1 | 1 |
6 | 13 | 1896.60 | 52 | 10.68 | 3219 | 1788 | 5.32 / 1269.84 | 1 | 1 |
7 | 13 | 1090.72 | 52 | 12.30 | 2041 | 1305 | 6.63 / 1271.14 | 1 | 2 |
8 | 8 | -0.04 | 160 | 14.18 | 298 | 676 | 7.31 / 1271.82 | 1 | 2 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 25 | 14.00 | 450 | 157 | 0.16 / 1260.57 | 2 | 2 |
2 | 12 | 1110.48 | 124 | 5.74 | 1867 | 1329 | 1.49 / 1261.90 | 1 | 1 |
3 | 7 | 1109.20 | 24 | 10.14 | 1999 | 486 | 1.97 / 1262.38 | 1 | 1 |
4 | 13 | 1033.08 | 52 | 11.16 | 1901 | 1103 | 3.08 / 1263.49 | 1 | 1 |
5 | 13 | 93.32 | 52 | 13.91 | 461 | 333 | 3.41 / 1263.82 | 1 | 2 |
6 | 8 | 0.00 | 160 | 14.11 | 307 | 693 | 4.10 / 1264.51 | 2 | 4 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 26 | 14.00 | 474 | 173 | 0.17 / 1256.44 | 2 | 2 |
2 | 12 | 1125.20 | 124 | 5.82 | 1896 | 1368 | 1.54 / 1257.81 | 1 | 1 |
3 | 7 | 1124.00 | 24 | 9.99 | 2042 | 490 | 2.03 / 1258.30 | 1 | 2 |
4 | 13 | 1038.36 | 52 | 11.00 | 1911 | 1093 | 3.12 / 1259.39 | 1 | 1 |
5 | 13 | 98.72 | 52 | 13.91 | 465 | 336 | 3.46 / 1259.73 | 1 | 2 |
6 | 8 | -0.08 | 160 | 14.12 | 302 | 682 | 4.14 / 1260.41 | 2 | 3 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.84 | 24 | 14.05 | 466 | 157 | 0.16 / 1252.51 | 2 | 2 |
2 | 3 | 1036.20 | 1 | 11.26 | 1910 | 22 | 0.18 / 1252.54 | 1 | 1 |
3 | 3 | 1028.44 | 1 | 10.85 | 1894 | 21 | 0.20 / 1252.56 | 1 | 1 |
4 | 12 | 1130.84 | 124 | 6.98 | 1961 | 1697 | 1.90 / 1254.25 | 1 | 1 |
5 | 7 | 1126.28 | 24 | 10.37 | 2041 | 508 | 2.40 / 1254.76 | 1 | 2 |
6 | 13 | 599.96 | 52 | 12.94 | 1257 | 846 | 3.25 / 1255.61 | 1 | 2 |
7 | 8 | 0.12 | 160 | 14.14 | 292 | 661 | 3.91 / 1256.27 | 2 | 2 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.68 | 26 | 13.97 | 473 | 172 | 0.17 / 1245.00 | 2 | 2 |
2 | 12 | 1997.92 | 124 | 6.41 | 3210 | 2551 | 2.72 / 1247.55 | 1 | 1 |
3 | 7 | 1994.92 | 24 | 10.08 | 3393 | 821 | 3.54 / 1248.38 | 1 | 1 |
4 | 13 | 1907.72 | 52 | 10.78 | 3235 | 1813 | 5.36 / 1250.19 | 1 | 1 |
5 | 13 | 995.60 | 52 | 12.52 | 1886 | 1228 | 6.59 / 1251.42 | 1 | 1 |
6 | 13 | 34.52 | 52 | 14.09 | 356 | 261 | 6.85 / 1251.68 | 1 | 2 |
7 | 8 | 0.16 | 160 | 14.19 | 299 | 679 | 7.53 / 1252.36 | 2 | 3 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 25 | 13.97 | 468 | 163 | 0.16 / 1241.14 | 2 | 2 |
2 | 12 | 1125.64 | 124 | 6.63 | 1948 | 1601 | 1.76 / 1242.74 | 1 | 2 |
3 | 7 | 1121.40 | 24 | 10.31 | 2037 | 504 | 2.27 / 1243.25 | 2 | 2 |
4 | 13 | 707.16 | 52 | 12.63 | 1411 | 927 | 3.20 / 1244.17 | 1 | 2 |
5 | 8 | 0.00 | 160 | 14.14 | 291 | 658 | 3.85 / 1244.83 | 2 | 2 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.24 | 24 | 13.89 | 481 | 160 | 0.16 / 1236.94 | 1 | 2 |
2 | 12 | 1137.56 | 124 | 6.21 | 1949 | 1501 | 1.66 / 1238.44 | 1 | 1 |
3 | 7 | 1133.32 | 24 | 10.07 | 2059 | 498 | 2.16 / 1238.94 | 1 | 1 |
4 | 13 | 933.16 | 52 | 11.65 | 1779 | 1078 | 3.24 / 1240.02 | 1 | 1 |
5 | 13 | 25.72 | 52 | 13.98 | 351 | 255 | 3.49 / 1240.27 | 1 | 2 |
6 | 8 | 0.16 | 160 | 14.04 | 314 | 705 | 4.20 / 1240.98 | 1 | 3 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 25 | 13.99 | 468 | 164 | 0.16 / 1232.97 | 1 | 2 |
2 | 12 | 1068.32 | 124 | 7.40 | 1889 | 1733 | 1.90 / 1234.71 | 1 | 1 |
3 | 7 | 1062.72 | 24 | 10.42 | 1962 | 491 | 2.39 / 1235.20 | 1 | 1 |
4 | 13 | 610.92 | 52 | 12.73 | 1298 | 859 | 3.25 / 1236.06 | 1 | 2 |
5 | 8 | -0.24 | 160 | 13.98 | 323 | 722 | 3.97 / 1236.78 | 1 | 7 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.64 | 24 | 13.91 | 490 | 164 | 0.16 / 1225.53 | 1 | 2 |
2 | 3 | 1042.48 | 1 | 11.15 | 1950 | 22 | 0.19 / 1225.55 | 1 | 1 |
3 | 3 | 1025.44 | 1 | 10.47 | 1938 | 20 | 0.21 / 1225.58 | 1 | 1 |
4 | 12 | 1994.64 | 124 | 6.80 | 3313 | 2794 | 3.00 / 1228.37 | 1 | 1 |
5 | 7 | 1990.20 | 24 | 10.16 | 3391 | 827 | 3.83 / 1229.20 | 1 | 1 |
6 | 13 | 1888.96 | 52 | 11.02 | 3212 | 1841 | 5.67 / 1231.04 | 1 | 1 |
7 | 13 | 792.60 | 52 | 12.83 | 1590 | 1061 | 6.73 / 1232.10 | 1 | 2 |
8 | 8 | -0.20 | 160 | 14.08 | 317 | 714 | 7.44 / 1232.81 | 1 | 5 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 24 | 13.93 | 452 | 151 | 0.15 / 1221.52 | 1 | 2 |
2 | 3 | 1018.84 | 1 | 10.49 | 1934 | 20 | 0.17 / 1221.54 | 1 | 1 |
3 | 12 | 1112.44 | 124 | 6.62 | 1936 | 1589 | 1.76 / 1223.13 | 1 | 1 |
4 | 7 | 1108.04 | 24 | 10.36 | 2044 | 508 | 2.27 / 1223.63 | 1 | 1 |
5 | 13 | 788.60 | 52 | 12.35 | 1576 | 1012 | 3.28 / 1224.65 | 1 | 1 |
6 | 8 | 0.04 | 160 | 14.01 | 323 | 724 | 4.00 / 1225.37 | 1 | 8 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.84 | 24 | 13.93 | 496 | 166 | 0.17 / 1217.47 | 1 | 2 |
2 | 3 | 1026.56 | 1 | 10.90 | 1936 | 21 | 0.19 / 1217.49 | 1 | 1 |
3 | 12 | 1129.00 | 124 | 6.93 | 1970 | 1693 | 1.88 / 1219.19 | 1 | 1 |
4 | 7 | 1123.92 | 24 | 10.42 | 2065 | 516 | 2.40 / 1219.70 | 1 | 1 |
5 | 13 | 687.40 | 52 | 12.63 | 1426 | 937 | 3.33 / 1220.64 | 1 | 2 |
6 | 8 | -0.32 | 160 | 14.01 | 323 | 724 | 4.06 / 1221.36 | 1 | 8 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 26 | 13.89 | 494 | 178 | 0.18 / 1213.61 | 1 | 1 |
2 | 3 | 923.60 | -1 | 15.04 | 0 | 0 | 0.00 / 1213.61 | 1 | 1 |
3 | 3 | 965.36 | -1 | 15.04 | 0 | 0 | 0.00 / 1213.61 | 1 | 1 |
4 | 12 | 1151.60 | 124 | 7.68 | 2028 | 1931 | 2.11 / 1215.54 | 1 | 1 |
5 | 7 | 1145.44 | 24 | 10.60 | 2096 | 533 | 2.64 / 1216.07 | 1 | 1 |
6 | 13 | 240.72 | 52 | 13.61 | 718 | 508 | 3.15 / 1216.58 | 1 | 3 |
7 | 8 | -0.08 | 160 | 14.02 | 325 | 729 | 3.88 / 1217.31 | 1 | 8 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.88 | 26 | 13.83 | 496 | 178 | 0.18 / 1206.80 | 1 | 1 |
2 | 3 | 921.08 | -1 | 15.02 | 0 | 0 | 0.00 / 1206.80 | 1 | 1 |
3 | 3 | 972.12 | -1 | 15.01 | 0 | 0 | 0.00 / 1206.80 | 1 | 1 |
4 | 12 | 1997.60 | 124 | 6.97 | 3320 | 2869 | 3.05 / 1209.67 | 1 | 1 |
5 | 7 | 1992.96 | 24 | 10.21 | 3399 | 833 | 3.88 / 1210.50 | 1 | 1 |
6 | 13 | 1490.44 | 52 | 11.77 | 2649 | 1621 | 5.50 / 1212.12 | 1 | 1 |
7 | 13 | 275.96 | 52 | 13.60 | 784 | 554 | 6.06 / 1212.68 | 1 | 4 |
8 | 8 | -0.32 | 160 | 14.00 | 335 | 750 | 6.81 / 1213.43 | 1 | 8 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 25 | 13.87 | 489 | 170 | 0.17 / 1202.80 | 1 | 2 |
2 | 3 | 950.52 | -1 | 15.02 | 0 | 0 | 0.00 / 1202.80 | 1 | 2 |
3 | 12 | 1107.08 | 124 | 6.30 | 1912 | 1494 | 1.66 / 1204.29 | 1 | 1 |
4 | 7 | 1102.96 | 24 | 10.35 | 2040 | 507 | 2.17 / 1204.80 | 1 | 1 |
5 | 13 | 894.52 | 52 | 12.02 | 1735 | 1084 | 3.25 / 1205.88 | 1 | 1 |
6 | 8 | 0.08 | 160 | 13.95 | 331 | 739 | 3.99 / 1206.62 | 1 | 7 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 25 | 13.97 | 467 | 163 | 0.16 / 1198.84 | 2 | 2 |
2 | 12 | 1062.68 | 124 | 6.53 | 1853 | 1500 | 1.66 / 1200.34 | 1 | 1 |
3 | 7 | 1058.12 | 24 | 10.46 | 1980 | 497 | 2.16 / 1200.84 | 1 | 1 |
4 | 13 | 842.84 | 52 | 12.12 | 1664 | 1049 | 3.21 / 1201.88 | 1 | 1 |
5 | 8 | -0.16 | 160 | 13.95 | 333 | 743 | 3.95 / 1202.63 | 1 | 8 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 26 | 14.04 | 465 | 170 | 0.17 / 1195.12 | 2 | 2 |
2 | 3 | 939.56 | -1 | 15.11 | 0 | 0 | 0.00 / 1195.12 | 2 | 2 |
3 | 12 | 1114.32 | 124 | 7.71 | 1952 | 1866 | 2.04 / 1196.99 | 1 | 1 |
4 | 7 | 1108.76 | 24 | 10.77 | 2029 | 524 | 2.56 / 1197.51 | 1 | 1 |
5 | 13 | 216.56 | 52 | 13.70 | 656 | 467 | 3.03 / 1197.98 | 1 | 2 |
6 | 8 | -0.12 | 160 | 14.08 | 308 | 694 | 3.72 / 1198.68 | 2 | 3 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 26 | 13.97 | 467 | 170 | 0.17 / 1188.66 | 2 | 2 |
2 | 12 | 1998.64 | 124 | 7.11 | 3313 | 2921 | 3.09 / 1191.58 | 1 | 1 |
3 | 7 | 1993.24 | 24 | 10.41 | 3384 | 845 | 3.94 / 1192.42 | 1 | 1 |
4 | 13 | 1326.36 | 52 | 12.11 | 2400 | 1511 | 5.45 / 1193.93 | 1 | 2 |
5 | 13 | 83.60 | 52 | 14.01 | 443 | 323 | 5.77 / 1194.26 | 1 | 2 |
6 | 8 | 0.28 | 160 | 14.17 | 307 | 696 | 6.47 / 1194.95 | 2 | 3 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.36 | 26 | 13.93 | 470 | 170 | 0.17 / 1184.71 | 2 | 2 |
2 | 12 | 1118.68 | 124 | 6.81 | 1927 | 1627 | 1.80 / 1186.34 | 1 | 2 |
3 | 7 | 1114.36 | 24 | 10.68 | 2025 | 519 | 2.32 / 1186.86 | 2 | 2 |
4 | 13 | 697.04 | 52 | 12.77 | 1414 | 939 | 3.26 / 1187.80 | 1 | 2 |
5 | 8 | 0.00 | 160 | 14.09 | 307 | 692 | 3.95 / 1188.49 | 2 | 5 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 26 | 13.91 | 482 | 174 | 0.17 / 1180.45 | 2 | 2 |
2 | 3 | 970.48 | -1 | 15.08 | 0 | 0 | 0.00 / 1180.45 | 2 | 2 |
3 | 3 | 1039.48 | 1 | 10.97 | 1905 | 21 | 0.20 / 1180.47 | 1 | 1 |
4 | 12 | 1135.72 | 124 | 6.88 | 1962 | 1674 | 1.87 / 1182.14 | 1 | 1 |
5 | 7 | 1131.24 | 24 | 10.60 | 2068 | 526 | 2.40 / 1182.67 | 1 | 1 |
6 | 13 | 1029.36 | 52 | 11.80 | 1918 | 1177 | 3.57 / 1183.84 | 1 | 1 |
7 | 8 | 0.08 | 160 | 14.08 | 309 | 696 | 4.27 / 1184.54 | 1 | 2 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.76 | 25 | 14.01 | 468 | 164 | 0.16 / 1176.51 | 2 | 2 |
2 | 3 | 1034.80 | 1 | 11.46 | 1909 | 22 | 0.19 / 1176.53 | 1 | 1 |
3 | 12 | 1117.36 | 124 | 8.02 | 1970 | 1959 | 2.14 / 1178.49 | 1 | 1 |
4 | 7 | 1111.36 | 24 | 10.89 | 2030 | 531 | 2.68 / 1179.02 | 1 | 1 |
5 | 13 | 309.40 | 52 | 13.56 | 793 | 559 | 3.23 / 1179.58 | 1 | 2 |
6 | 8 | 0.12 | 160 | 14.07 | 308 | 693 | 3.93 / 1180.27 | 2 | 4 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.68 | 25 | 13.94 | 485 | 169 | 0.17 / 1170.31 | 2 | 2 |
2 | 3 | 1025.56 | 1 | 10.75 | 1893 | 20 | 0.19 / 1170.33 | 1 | 1 |
3 | 12 | 1991.96 | 124 | 7.46 | 3296 | 3049 | 3.24 / 1173.38 | 1 | 1 |
4 | 7 | 1985.96 | 24 | 10.49 | 3364 | 847 | 4.09 / 1174.22 | 1 | 1 |
5 | 13 | 1207.52 | 52 | 12.29 | 2215 | 1416 | 5.50 / 1175.64 | 1 | 2 |
6 | 8 | 0.12 | 160 | 14.16 | 311 | 705 | 6.21 / 1176.34 | 2 | 3 |
Average= | 5.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 25 | 13.94 | 481 | 168 | 0.17 / 1166.42 | 2 | 2 |
2 | 12 | 1125.84 | 124 | 7.28 | 1958 | 1768 | 1.94 / 1168.19 | 1 | 1 |
3 | 7 | 1121.04 | 24 | 10.86 | 2045 | 533 | 2.47 / 1168.72 | 1 | 2 |
4 | 13 | 461.20 | 52 | 13.28 | 1039 | 717 | 3.19 / 1169.44 | 1 | 2 |
5 | 8 | -0.08 | 160 | 14.06 | 312 | 702 | 3.89 / 1170.14 | 2 | 4 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 25 | 13.96 | 479 | 167 | 0.17 / 1162.57 | 2 | 2 |
2 | 12 | 1125.28 | 124 | 7.76 | 1972 | 1898 | 2.06 / 1164.46 | 1 | 1 |
3 | 7 | 1120.36 | 24 | 10.91 | 2041 | 534 | 2.60 / 1165.00 | 1 | 2 |
4 | 13 | 315.36 | 52 | 13.55 | 807 | 569 | 3.17 / 1165.57 | 1 | 2 |
5 | 8 | -0.08 | 160 | 14.07 | 304 | 684 | 3.85 / 1166.25 | 2 | 3 |
Average= | 5.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.04 | 25 | 13.98 | 476 | 166 | 0.17 / 1158.78 | 2 | 2 |
2 | 3 | 966.28 | -1 | 15.09 | 0 | 0 | 0.00 / 1158.78 | 2 | 2 |
3 | 3 | 1021.48 | 1 | 10.97 | 1912 | 21 | 0.19 / 1158.80 | 1 | 1 |
4 | 12 | 1140.84 | 124 | 8.32 | 2022 | 2086 | 2.27 / 1160.89 | 1 | 1 |
5 | 7 | 1134.60 | 24 | 10.95 | 2080 | 547 | 2.82 / 1161.44 | 1 | 1 |
6 | 13 | 36.56 | 52 | 13.99 | 365 | 266 | 3.09 / 1161.70 | 1 | 2 |
7 | 8 | 0.04 | 160 | 14.06 | 310 | 697 | 3.78 / 1162.40 | 2 | 4 |
Average= | 5.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 25 | 13.90 | 490 | 170 | 0.17 / 1152.37 | 2 | 2 |
2 | 12 | 1992.28 | 124 | 7.97 | 3334 | 3295 | 3.47 / 1155.67 | 1 | 1 |
3 | 7 | 1986.04 | 24 | 10.54 | 3369 | 852 | 4.32 / 1156.52 | 1 | 2 |
4 | 13 | 1152.44 | 52 | 12.40 | 2146 | 1384 | 5.70 / 1157.90 | 1 | 2 |
5 | 8 | 0.12 | 160 | 14.13 | 316 | 714 | 6.42 / 1158.62 | 1 | 4 |
Average= | 5.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.08 | 26 | 13.94 | 471 | 171 | 0.17 / 1148.36 | 2 | 2 |
2 | 3 | 948.60 | -1 | 15.10 | 0 | 0 | 0.00 / 1148.36 | 2 | 2 |
3 | 3 | 1020.52 | 1 | 10.44 | 1915 | 20 | 0.19 / 1148.38 | 1 | 1 |
4 | 12 | 1122.76 | 124 | 7.19 | 1948 | 1737 | 1.93 / 1150.11 | 1 | 1 |
5 | 7 | 1117.68 | 24 | 10.89 | 2057 | 538 | 2.47 / 1150.65 | 1 | 1 |
6 | 13 | 570.64 | 52 | 13.07 | 1220 | 829 | 3.29 / 1151.48 | 1 | 2 |
7 | 8 | -0.12 | 160 | 14.03 | 321 | 721 | 4.01 / 1152.20 | 1 | 3 |
Average= | 5.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.48 | 26 | 13.91 | 493 | 178 | 0.18 / 1144.59 | 2 | 2 |
2 | 12 | 1096.44 | 124 | 7.76 | 1908 | 1836 | 2.01 / 1146.43 | 1 | 1 |
3 | 7 | 1091.20 | 24 | 11.09 | 1987 | 529 | 2.54 / 1146.96 | 1 | 1 |
4 | 13 | 104.36 | 52 | 13.87 | 469 | 338 | 2.88 / 1147.29 | 1 | 2 |
5 | 8 | -0.08 | 160 | 14.06 | 302 | 679 | 3.56 / 1147.97 | 2 | 5 |
6 | 14 | -0.08 | 50 | 14.09 | 301 | 212 | 3.77 / 1148.19 | 2 | 2 |
Average= | 5.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.52 | 25 | 13.97 | 485 | 169 | 0.17 / 1140.79 | 2 | 2 |
2 | 12 | 1127.32 | 124 | 8.50 | 1984 | 2091 | 2.26 / 1142.89 | 1 | 2 |
3 | 7 | 1120.92 | 24 | 11.12 | 2047 | 546 | 2.81 / 1143.43 | 2 | 2 |
4 | 13 | 73.16 | 52 | 13.95 | 414 | 300 | 3.11 / 1143.73 | 1 | 2 |
5 | 8 | 0.16 | 160 | 14.08 | 302 | 680 | 3.79 / 1144.41 | 2 | 4 |
Average= | 5.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.64 | 25 | 13.88 | 480 | 167 | 0.17 / 1134.44 | 2 | 2 |
2 | 12 | 2002.92 | 124 | 7.81 | 3341 | 3236 | 3.40 / 1137.67 | 1 | 1 |
3 | 7 | 1997.28 | 24 | 10.60 | 3378 | 859 | 4.26 / 1138.53 | 1 | 1 |
4 | 13 | 1171.92 | 52 | 12.42 | 2162 | 1396 | 5.66 / 1139.93 | 1 | 2 |
5 | 8 | 0.16 | 160 | 14.18 | 308 | 699 | 6.36 / 1140.63 | 2 | 3 |
Average= | 5.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 25 | 13.94 | 485 | 169 | 0.17 / 1130.71 | 2 | 2 |
2 | 12 | 1122.48 | 124 | 7.60 | 1942 | 1830 | 2.00 / 1132.54 | 1 | 2 |
3 | 7 | 1117.24 | 24 | 11.11 | 2041 | 544 | 2.54 / 1133.08 | 2 | 2 |
4 | 13 | 227.36 | 52 | 13.70 | 675 | 481 | 3.02 / 1133.56 | 1 | 2 |
5 | 8 | 0.08 | 160 | 14.06 | 314 | 706 | 3.73 / 1134.27 | 2 | 3 |
Average= | 5.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 26 | 13.95 | 473 | 172 | 0.17 / 1126.97 | 2 | 2 |
2 | 3 | 940.24 | -1 | 15.11 | 0 | 0 | 0.00 / 1126.97 | 2 | 2 |
3 | 12 | 1115.60 | 124 | 7.73 | 1944 | 1863 | 2.03 / 1128.84 | 1 | 1 |
4 | 7 | 1110.52 | 24 | 11.18 | 2028 | 544 | 2.58 / 1129.38 | 1 | 2 |
5 | 13 | 209.96 | 52 | 13.72 | 635 | 453 | 3.03 / 1129.83 | 1 | 2 |
6 | 8 | -0.08 | 160 | 14.06 | 313 | 704 | 3.74 / 1130.54 | 2 | 3 |
Average= | 5.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 26 | 14.04 | 454 | 166 | 0.17 / 1123.18 | 2 | 2 |
2 | 3 | 972.92 | -1 | 15.13 | 0 | 0 | 0.00 / 1123.18 | 2 | 2 |
3 | 3 | 1043.04 | 1 | 11.63 | 1917 | 22 | 0.19 / 1123.20 | 1 | 1 |
4 | 12 | 1131.08 | 124 | 8.64 | 1996 | 2138 | 2.33 / 1125.34 | 1 | 2 |
5 | 7 | 1124.32 | 24 | 11.26 | 2032 | 549 | 2.88 / 1125.89 | 2 | 2 |
6 | 13 | 17.64 | 52 | 14.05 | 321 | 235 | 3.11 / 1126.12 | 1 | 2 |
7 | 8 | 0.12 | 160 | 14.09 | 301 | 679 | 3.79 / 1126.80 | 2 | 3 |
Average= | 5.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.88 | 25 | 13.95 | 449 | 157 | 0.16 / 1117.12 | 2 | 2 |
2 | 12 | 1993.68 | 124 | 7.87 | 3317 | 3237 | 3.39 / 1120.36 | 1 | 1 |
3 | 7 | 1987.16 | 24 | 10.64 | 3352 | 856 | 4.25 / 1121.22 | 1 | 1 |
4 | 13 | 868.36 | 52 | 12.90 | 1684 | 1130 | 5.38 / 1122.35 | 1 | 2 |
5 | 8 | 0.00 | 160 | 14.20 | 294 | 668 | 6.05 / 1123.01 | 2 | 3 |
Average= | 5.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 25 | 14.00 | 459 | 161 | 0.16 / 1113.42 | 2 | 2 |
2 | 12 | 1103.08 | 124 | 8.09 | 1929 | 1935 | 2.10 / 1115.36 | 1 | 2 |
3 | 7 | 1097.16 | 24 | 11.31 | 2006 | 545 | 2.64 / 1115.90 | 2 | 2 |
4 | 13 | 167.96 | 52 | 13.79 | 567 | 407 | 3.05 / 1116.31 | 1 | 2 |
5 | 8 | 0.12 | 160 | 14.09 | 291 | 656 | 3.70 / 1116.97 | 2 | 4 |
Average= | 5.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.24 | 26 | 13.96 | 471 | 171 | 0.17 / 1109.70 | 2 | 2 |
2 | 12 | 1126.00 | 124 | 8.23 | 1974 | 2015 | 2.19 / 1111.72 | 1 | 2 |
3 | 7 | 1120.04 | 24 | 11.29 | 2037 | 552 | 2.74 / 1112.27 | 2 | 2 |
4 | 13 | 90.08 | 52 | 13.91 | 442 | 320 | 3.06 / 1112.59 | 1 | 2 |
5 | 8 | -0.04 | 160 | 14.09 | 300 | 676 | 3.73 / 1113.26 | 2 | 3 |
Average= | 5.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.24 | 26 | 14.00 | 479 | 174 | 0.17 / 1106.06 | 2 | 2 |
2 | 3 | 963.68 | -1 | 15.13 | 0 | 0 | 0.00 / 1106.06 | 2 | 2 |
3 | 3 | 1026.88 | 1 | 11.66 | 1901 | 22 | 0.20 / 1106.08 | 1 | 1 |
4 | 12 | 1126.20 | 124 | 8.97 | 1993 | 2217 | 2.41 / 1108.30 | 1 | 1 |
5 | 7 | 1119.64 | 24 | 11.28 | 2036 | 551 | 2.96 / 1108.85 | 1 | 2 |
6 | 8 | 0.20 | 160 | 14.08 | 301 | 678 | 3.64 / 1109.53 | 2 | 2 |
Average= | 5.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 25 | 13.95 | 464 | 162 | 0.16 / 1099.74 | 2 | 2 |
2 | 12 | 1992.24 | 124 | 8.27 | 3323 | 3408 | 3.57 / 1103.15 | 1 | 1 |
3 | 7 | 1985.52 | 24 | 10.67 | 3358 | 860 | 4.43 / 1104.01 | 1 | 2 |
4 | 13 | 920.96 | 52 | 12.80 | 1769 | 1177 | 5.61 / 1105.19 | 1 | 2 |
5 | 8 | 0.04 | 160 | 14.18 | 309 | 701 | 6.31 / 1105.89 | 2 | 2 |
Average= | 5.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.08 | 25 | 13.98 | 472 | 165 | 0.16 / 1096.02 | 2 | 2 |
2 | 12 | 1121.28 | 124 | 8.17 | 1972 | 1998 | 2.16 / 1098.02 | 1 | 2 |
3 | 7 | 1115.08 | 24 | 11.22 | 2048 | 551 | 2.71 / 1098.57 | 2 | 2 |
4 | 13 | 90.96 | 52 | 13.88 | 456 | 329 | 3.04 / 1098.90 | 1 | 2 |
5 | 8 | 0.08 | 160 | 14.07 | 302 | 680 | 3.72 / 1099.58 | 2 | 3 |
Average= | 5.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 26 | 13.94 | 471 | 171 | 0.17 / 1092.28 | 2 | 2 |
2 | 12 | 1123.16 | 124 | 8.44 | 1968 | 2060 | 2.23 / 1094.34 | 1 | 2 |
3 | 7 | 1116.44 | 24 | 11.30 | 2040 | 553 | 2.78 / 1094.89 | 2 | 2 |
4 | 13 | 71.60 | 52 | 13.93 | 413 | 299 | 3.08 / 1095.19 | 1 | 2 |
5 | 8 | 0.08 | 160 | 14.09 | 294 | 663 | 3.75 / 1095.86 | 2 | 3 |
Average= | 5.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.52 | 26 | 14.04 | 470 | 172 | 0.17 / 1088.56 | 2 | 2 |
2 | 3 | 966.88 | -1 | 15.13 | 0 | 0 | 0.00 / 1088.56 | 2 | 2 |
3 | 3 | 1027.04 | 1 | 11.78 | 1901 | 22 | 0.19 / 1088.58 | 1 | 1 |
4 | 12 | 1139.60 | 124 | 9.11 | 2024 | 2286 | 2.48 / 1090.87 | 1 | 1 |
5 | 7 | 1133.56 | 24 | 11.34 | 2058 | 560 | 3.04 / 1091.43 | 1 | 2 |
6 | 8 | 0.48 | 160 | 14.09 | 302 | 681 | 3.72 / 1092.11 | 2 | 4 |
Average= | 5.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.28 | 25 | 13.99 | 455 | 159 | 0.16 / 1082.22 | 2 | 2 |
2 | 12 | 1992.80 | 124 | 8.37 | 3320 | 3446 | 3.60 / 1085.66 | 1 | 1 |
3 | 7 | 1986.04 | 24 | 10.71 | 3348 | 861 | 4.47 / 1086.52 | 1 | 1 |
4 | 13 | 910.36 | 52 | 12.81 | 1754 | 1168 | 5.63 / 1087.69 | 1 | 2 |
5 | 8 | -0.08 | 160 | 14.18 | 308 | 699 | 6.33 / 1088.39 | 2 | 5 |
Average= | 5.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 25 | 14.00 | 465 | 163 | 0.16 / 1078.50 | 2 | 2 |
2 | 12 | 1105.04 | 124 | 8.57 | 1943 | 2065 | 2.23 / 1080.57 | 1 | 1 |
3 | 7 | 1099.04 | 24 | 11.34 | 2009 | 547 | 2.77 / 1081.11 | 1 | 2 |
4 | 13 | 57.60 | 52 | 13.96 | 388 | 282 | 3.06 / 1081.40 | 1 | 2 |
5 | 8 | -0.24 | 160 | 14.09 | 293 | 661 | 3.72 / 1082.06 | 2 | 2 |
Average= | 5.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 25 | 13.98 | 461 | 161 | 0.16 / 1074.71 | 2 | 2 |
2 | 3 | 1019.48 | 1 | 11.49 | 1905 | 22 | 0.18 / 1074.73 | 1 | 1 |
3 | 12 | 1112.56 | 124 | 8.60 | 1963 | 2093 | 2.28 / 1076.83 | 1 | 1 |
4 | 7 | 1106.04 | 24 | 11.37 | 2021 | 551 | 2.83 / 1077.38 | 1 | 2 |
5 | 13 | 62.56 | 52 | 13.95 | 400 | 290 | 3.12 / 1077.67 | 1 | 2 |
6 | 8 | -0.12 | 160 | 14.10 | 297 | 670 | 3.79 / 1078.34 | 2 | 2 |
Average= | 5.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.48 | 25 | 14.04 | 469 | 165 | 0.16 / 1071.03 | 2 | 2 |
2 | 12 | 1107.76 | 124 | 9.39 | 1978 | 2303 | 2.47 / 1073.33 | 1 | 1 |
3 | 7 | 1101.04 | 24 | 11.46 | 2016 | 554 | 3.02 / 1073.89 | 1 | 2 |
4 | 8 | -0.12 | 160 | 14.08 | 296 | 667 | 3.69 / 1074.55 | 2 | 2 |
Average= | 5.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.76 | 25 | 13.98 | 465 | 163 | 0.16 / 1064.48 | 2 | 2 |
2 | 12 | 1995.24 | 124 | 8.60 | 3337 | 3559 | 3.72 / 1068.04 | 1 | 1 |
3 | 7 | 1988.68 | 24 | 10.73 | 3379 | 870 | 4.59 / 1068.91 | 1 | 1 |
4 | 13 | 998.16 | 52 | 12.68 | 1894 | 1249 | 5.84 / 1070.16 | 1 | 1 |
5 | 8 | 0.12 | 160 | 14.19 | 309 | 702 | 6.54 / 1070.86 | 2 | 3 |
Average= | 5.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.12 | 25 | 13.99 | 454 | 159 | 0.16 / 1060.70 | 2 | 2 |
2 | 12 | 1106.52 | 124 | 8.83 | 1955 | 2141 | 2.30 / 1062.84 | 1 | 1 |
3 | 7 | 1100.12 | 24 | 11.46 | 2017 | 555 | 2.85 / 1063.39 | 1 | 1 |
4 | 13 | 24.52 | 52 | 14.01 | 341 | 248 | 3.10 / 1063.64 | 1 | 2 |
5 | 8 | 0.20 | 160 | 14.09 | 302 | 681 | 3.78 / 1064.32 | 2 | 2 |
Average= | 5.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.04 | 25 | 13.96 | 479 | 167 | 0.17 / 1056.78 | 2 | 2 |
2 | 12 | 1122.00 | 124 | 8.98 | 1981 | 2206 | 2.37 / 1058.98 | 1 | 2 |
3 | 7 | 1115.92 | 25 | 11.51 | 2042 | 588 | 2.96 / 1059.57 | 2 | 2 |
4 | 13 | 51.00 | 52 | 13.97 | 390 | 283 | 3.24 / 1059.85 | 1 | 2 |
5 | 8 | 0.04 | 160 | 14.10 | 304 | 686 | 3.93 / 1060.54 | 2 | 5 |
Average= | 5.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 25 | 14.05 | 485 | 170 | 0.17 / 1052.73 | 2 | 2 |
2 | 12 | 1121.88 | 124 | 9.50 | 2004 | 2361 | 2.53 / 1055.09 | 1 | 2 |
3 | 7 | 1115.08 | 24 | 11.51 | 2046 | 565 | 3.10 / 1055.66 | 2 | 2 |
4 | 13 | 34.68 | 52 | 14.00 | 358 | 261 | 3.36 / 1055.92 | 1 | 2 |
5 | 8 | 0.00 | 160 | 14.10 | 305 | 688 | 4.04 / 1056.61 | 2 | 5 |
Average= | 5.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.88 | 25 | 14.00 | 459 | 161 | 0.16 / 1046.55 | 2 | 2 |
2 | 12 | 1993.44 | 124 | 8.86 | 3342 | 3672 | 3.83 / 1050.22 | 1 | 1 |
3 | 7 | 1986.28 | 24 | 10.80 | 3360 | 871 | 4.70 / 1051.10 | 1 | 1 |
4 | 13 | 486.16 | 52 | 13.44 | 1088 | 760 | 5.46 / 1051.86 | 1 | 2 |
5 | 8 | 0.20 | 160 | 14.17 | 312 | 707 | 6.17 / 1052.56 | 2 | 2 |
Average= | 5.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.84 | 25 | 13.99 | 464 | 162 | 0.16 / 1042.69 | 2 | 2 |
2 | 12 | 1107.28 | 124 | 8.90 | 1962 | 2165 | 2.33 / 1044.86 | 1 | 2 |
3 | 7 | 1099.96 | 24 | 11.56 | 2025 | 562 | 2.89 / 1045.42 | 2 | 2 |
4 | 13 | 49.36 | 52 | 13.98 | 380 | 276 | 3.17 / 1045.70 | 1 | 2 |
5 | 8 | 0.20 | 160 | 14.10 | 308 | 695 | 3.86 / 1046.39 | 2 | 2 |
Average= | 5.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 25 | 14.02 | 459 | 161 | 0.16 / 1038.76 | 2 | 2 |
2 | 12 | 1102.52 | 124 | 9.29 | 1973 | 2273 | 2.43 / 1041.03 | 1 | 2 |
3 | 7 | 1096.12 | 24 | 11.63 | 2015 | 562 | 3.00 / 1041.59 | 2 | 2 |
4 | 13 | 36.28 | 52 | 14.00 | 358 | 261 | 3.26 / 1041.85 | 1 | 2 |
5 | 8 | 0.12 | 160 | 14.11 | 301 | 680 | 3.94 / 1042.53 | 2 | 3 |
Average= | 5.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.12 | 26 | 14.03 | 470 | 171 | 0.17 / 1034.68 | 2 | 2 |
2 | 12 | 1111.48 | 124 | 9.70 | 1992 | 2396 | 2.57 / 1037.08 | 1 | 1 |
3 | 7 | 1104.24 | 24 | 11.54 | 2021 | 560 | 3.13 / 1037.64 | 1 | 2 |
4 | 13 | 31.00 | 52 | 14.01 | 359 | 262 | 3.39 / 1037.90 | 1 | 2 |
5 | 8 | -0.12 | 160 | 14.10 | 308 | 695 | 4.08 / 1038.60 | 2 | 3 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.60 | 25 | 13.98 | 462 | 161 | 0.16 / 1028.15 | 2 | 2 |
2 | 12 | 1993.68 | 124 | 9.05 | 3349 | 3758 | 3.92 / 1031.91 | 1 | 1 |
3 | 7 | 1986.84 | 24 | 10.86 | 3378 | 880 | 4.80 / 1032.79 | 1 | 2 |
4 | 13 | 740.60 | 52 | 13.08 | 1492 | 1015 | 5.81 / 1033.80 | 1 | 2 |
5 | 8 | -0.08 | 160 | 14.19 | 312 | 708 | 6.52 / 1034.51 | 2 | 3 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.16 | 26 | 14.01 | 459 | 167 | 0.17 / 1024.22 | 2 | 2 |
2 | 12 | 1101.68 | 124 | 9.22 | 1964 | 2245 | 2.41 / 1026.47 | 1 | 1 |
3 | 7 | 1094.96 | 24 | 11.64 | 2003 | 560 | 2.97 / 1027.03 | 1 | 2 |
4 | 13 | 38.20 | 52 | 14.00 | 366 | 266 | 3.24 / 1027.30 | 1 | 2 |
5 | 8 | 0.00 | 160 | 14.10 | 307 | 693 | 3.93 / 1027.99 | 2 | 5 |
Average= | 5.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.48 | 25 | 14.00 | 453 | 159 | 0.16 / 1020.19 | 2 | 2 |
2 | 12 | 1120.16 | 124 | 9.37 | 1992 | 2314 | 2.47 / 1022.51 | 1 | 1 |
3 | 7 | 1112.64 | 24 | 11.65 | 2040 | 570 | 3.04 / 1023.08 | 1 | 2 |
4 | 13 | 36.72 | 52 | 13.99 | 373 | 271 | 3.31 / 1023.35 | 1 | 2 |
5 | 8 | -0.24 | 160 | 14.10 | 314 | 708 | 4.02 / 1024.06 | 2 | 4 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 25 | 14.05 | 473 | 166 | 0.17 / 1016.30 | 2 | 2 |
2 | 12 | 1118.52 | 124 | 9.90 | 2008 | 2465 | 2.63 / 1018.77 | 1 | 2 |
3 | 7 | 1111.20 | 24 | 11.59 | 2041 | 568 | 3.20 / 1019.34 | 2 | 2 |
4 | 8 | 0.44 | 160 | 14.07 | 310 | 698 | 3.90 / 1020.03 | 2 | 4 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.24 | 25 | 13.96 | 471 | 164 | 0.16 / 1009.99 | 2 | 2 |
2 | 12 | 1990.68 | 124 | 9.34 | 3356 | 3887 | 4.05 / 1013.88 | 1 | 1 |
3 | 7 | 1983.32 | 24 | 10.90 | 3363 | 880 | 4.93 / 1014.76 | 1 | 1 |
4 | 13 | 380.72 | 52 | 13.53 | 939 | 661 | 5.59 / 1015.42 | 1 | 2 |
5 | 8 | -0.12 | 160 | 14.13 | 319 | 721 | 6.31 / 1016.14 | 2 | 2 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.24 | 26 | 13.99 | 462 | 168 | 0.17 / 1006.22 | 2 | 2 |
2 | 12 | 1103.88 | 124 | 9.53 | 1989 | 2350 | 2.52 / 1008.57 | 1 | 1 |
3 | 7 | 1096.96 | 24 | 11.57 | 2018 | 560 | 3.08 / 1009.13 | 1 | 1 |
4 | 8 | 0.24 | 160 | 14.05 | 310 | 697 | 3.78 / 1009.82 | 2 | 2 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 25 | 14.03 | 457 | 160 | 0.16 / 1002.31 | 2 | 2 |
2 | 12 | 1121.48 | 118 | 9.50 | 2006 | 2249 | 2.41 / 1004.56 | 1 | 1 |
3 | 7 | 1115.00 | 24 | 11.59 | 2041 | 568 | 2.98 / 1005.12 | 1 | 1 |
4 | 13 | 20.64 | 52 | 14.02 | 337 | 246 | 3.22 / 1005.37 | 1 | 2 |
5 | 8 | 0.16 | 160 | 14.10 | 301 | 679 | 3.90 / 1006.05 | 2 | 3 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.08 | 26 | 14.05 | 455 | 166 | 0.17 / 998.31 | 2 | 2 |
2 | 3 | 934.80 | -1 | 15.11 | 0 | 0 | 0.00 / 998.31 | 2 | 2 |
3 | 12 | 1105.60 | 118 | 9.87 | 1991 | 2319 | 2.49 / 1000.62 | 1 | 1 |
4 | 7 | 1098.32 | 24 | 11.63 | 2021 | 564 | 3.05 / 1001.19 | 1 | 2 |
5 | 13 | 25.32 | 52 | 14.03 | 352 | 257 | 3.31 / 1001.45 | 1 | 2 |
6 | 8 | -0.32 | 160 | 14.10 | 311 | 702 | 4.01 / 1002.15 | 2 | 6 |
Average= | 5.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 26 | 14.00 | 459 | 167 | 0.17 / 992.75 | 1 | 2 |
2 | 3 | 944.84 | -1 | 15.11 | 0 | 0 | 0.00 / 992.75 | 1 | 2 |
3 | 12 | 1116.00 | 5 | 12.00 | 2037 | 122 | 0.29 / 992.87 | 1 | 1 |
4 | 12 | 1710.00 | 118 | 10.11 | 2953 | 3523 | 3.81 / 996.40 | 1 | 1 |
5 | 7 | 1702.48 | 25 | 11.09 | 2943 | 816 | 4.63 / 997.21 | 1 | 1 |
6 | 13 | 17.20 | 52 | 14.08 | 337 | 247 | 4.87 / 997.46 | 1 | 2 |
7 | 8 | 0.20 | 160 | 14.15 | 301 | 681 | 5.56 / 998.14 | 2 | 7 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 22 | 13.98 | 489 | 150 | 0.15 / 988.70 | 1 | 2 |
2 | 3 | 1099.92 | 3 | 12.47 | 2023 | 76 | 0.23 / 988.78 | 1 | 1 |
3 | 3 | 1037.84 | 1 | 12.10 | 1935 | 23 | 0.25 / 988.80 | 1 | 1 |
4 | 12 | 1127.40 | 118 | 9.50 | 2018 | 2262 | 2.51 / 991.06 | 1 | 1 |
5 | 7 | 1120.52 | 24 | 11.52 | 2064 | 571 | 3.08 / 991.63 | 1 | 1 |
6 | 13 | 18.96 | 52 | 14.03 | 339 | 247 | 3.33 / 991.88 | 1 | 2 |
7 | 8 | 0.08 | 160 | 14.08 | 312 | 703 | 4.03 / 992.58 | 2 | 3 |
Average= | 5.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 25 | 13.97 | 485 | 169 | 0.17 / 984.77 | 2 | 2 |
2 | 3 | 1027.44 | 1 | 12.11 | 1918 | 23 | 0.19 / 984.79 | 1 | 1 |
3 | 12 | 1105.88 | 118 | 9.55 | 1990 | 2243 | 2.44 / 987.03 | 1 | 1 |
4 | 7 | 1098.80 | 24 | 11.61 | 2025 | 564 | 3.00 / 987.60 | 1 | 1 |
5 | 13 | 15.32 | 52 | 14.03 | 338 | 247 | 3.25 / 987.84 | 1 | 2 |
6 | 8 | 0.00 | 160 | 14.08 | 314 | 707 | 3.95 / 988.55 | 2 | 7 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 25 | 14.08 | 465 | 164 | 0.16 / 980.90 | 2 | 2 |
2 | 12 | 1110.80 | 118 | 10.23 | 2013 | 2430 | 2.59 / 983.33 | 1 | 1 |
3 | 7 | 1103.92 | 24 | 11.68 | 2029 | 569 | 3.16 / 983.90 | 1 | 1 |
4 | 8 | 0.08 | 160 | 14.08 | 310 | 698 | 3.86 / 984.60 | 2 | 2 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.20 | 20 | 14.09 | 484 | 136 | 0.14 / 975.17 | 2 | 2 |
2 | 10 | 1041.28 | 3 | 13.13 | 1927 | 76 | 0.21 / 975.25 | 1 | 2 |
3 | 3 | 1088.88 | 2 | 12.75 | 2030 | 52 | 0.26 / 975.30 | 1 | 1 |
4 | 3 | 1026.52 | 1 | 12.14 | 1914 | 23 | 0.29 / 975.33 | 1 | 1 |
5 | 12 | 1116.24 | 5 | 12.60 | 2069 | 130 | 0.42 / 975.46 | 1 | 1 |
6 | 12 | 1708.00 | 118 | 10.75 | 2967 | 3764 | 4.18 / 979.22 | 1 | 1 |
7 | 7 | 1699.76 | 24 | 11.34 | 2938 | 800 | 4.98 / 980.02 | 1 | 1 |
8 | 8 | 0.04 | 160 | 14.19 | 316 | 717 | 5.70 / 980.74 | 2 | 4 |
Average= | 5.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 25 | 14.08 | 475 | 167 | 0.17 / 969.02 | 2 | 2 |
2 | 12 | 1998.72 | 118 | 7.59 | 3212 | 2877 | 3.04 / 971.90 | 1 | 1 |
3 | 7 | 1992.84 | 24 | 10.87 | 3386 | 883 | 3.93 / 972.78 | 1 | 1 |
4 | 13 | 1223.88 | 45 | 12.52 | 2257 | 1272 | 5.20 / 974.05 | 1 | 2 |
5 | 13 | 67.12 | 45 | 14.11 | 424 | 269 | 5.47 / 974.32 | 1 | 2 |
6 | 8 | -0.04 | 160 | 14.20 | 315 | 716 | 6.18 / 975.04 | 2 | 3 |
Average= | 5.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 26 | 14.10 | 472 | 173 | 0.17 / 962.85 | 1 | 2 |
2 | 3 | 961.24 | -1 | 15.17 | 0 | 0 | 0.00 / 962.85 | 1 | 2 |
3 | 3 | 1020.00 | 1 | 12.36 | 1922 | 24 | 0.20 / 962.88 | 1 | 1 |
4 | 12 | 1999.12 | 118 | 7.56 | 3218 | 2871 | 3.07 / 965.75 | 1 | 1 |
5 | 7 | 1993.68 | 24 | 10.93 | 3353 | 880 | 3.95 / 966.63 | 1 | 2 |
6 | 13 | 1223.00 | 45 | 12.56 | 2258 | 1276 | 5.22 / 967.91 | 1 | 1 |
7 | 13 | 29.20 | 45 | 14.19 | 355 | 227 | 5.45 / 968.13 | 1 | 2 |
8 | 8 | -0.16 | 160 | 14.21 | 318 | 723 | 6.17 / 968.85 | 2 | 4 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 26 | 14.08 | 484 | 177 | 0.18 / 956.94 | 2 | 2 |
2 | 12 | 2005.04 | 80 | 7.38 | 3178 | 1876 | 2.05 / 958.82 | 1 | 1 |
3 | 7 | 2000.84 | 24 | 10.84 | 3361 | 874 | 2.93 / 959.69 | 1 | 1 |
4 | 13 | 1697.00 | 34 | 12.21 | 2974 | 1235 | 4.16 / 960.93 | 1 | 1 |
5 | 13 | 1036.44 | 34 | 12.94 | 1969 | 866 | 5.03 / 961.80 | 1 | 2 |
6 | 13 | 15.80 | 34 | 14.21 | 342 | 165 | 5.19 / 961.96 | 1 | 2 |
7 | 8 | 0.20 | 160 | 14.21 | 317 | 721 | 5.91 / 962.68 | 2 | 3 |
Average= | 5.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.28 | 25 | 14.10 | 482 | 170 | 0.17 / 951.17 | 1 | 2 |
2 | 3 | 1022.60 | 1 | 12.49 | 1928 | 24 | 0.19 / 951.20 | 1 | 1 |
3 | 3 | 1019.28 | 1 | 12.27 | 1934 | 24 | 0.22 / 951.22 | 1 | 1 |
4 | 12 | 2007.04 | 80 | 7.54 | 3201 | 1931 | 2.15 / 953.15 | 1 | 1 |
5 | 7 | 2002.96 | 24 | 10.82 | 3397 | 882 | 3.03 / 954.03 | 1 | 2 |
6 | 13 | 1694.28 | 34 | 12.22 | 2960 | 1230 | 4.26 / 955.26 | 1 | 1 |
7 | 13 | 892.20 | 34 | 13.10 | 1743 | 776 | 5.04 / 956.04 | 1 | 2 |
8 | 8 | 0.04 | 160 | 14.21 | 320 | 728 | 5.76 / 956.77 | 2 | 4 |
Average= | 5.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.76 | 25 | 14.10 | 465 | 164 | 0.16 / 945.54 | 2 | 2 |
2 | 12 | 2000.64 | 80 | 7.56 | 3184 | 1926 | 2.09 / 947.47 | 1 | 1 |
3 | 7 | 1995.88 | 24 | 10.85 | 3371 | 878 | 2.97 / 948.34 | 1 | 2 |
4 | 13 | 1701.08 | 34 | 12.21 | 2970 | 1233 | 4.20 / 949.58 | 1 | 1 |
5 | 13 | 811.36 | 34 | 13.18 | 1612 | 722 | 4.92 / 950.30 | 1 | 2 |
6 | 8 | 0.04 | 160 | 14.21 | 309 | 703 | 5.63 / 951.00 | 2 | 2 |
Average= | 5.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 25 | 14.13 | 472 | 167 | 0.17 / 939.87 | 2 | 2 |
2 | 12 | 2001.96 | 80 | 7.55 | 3183 | 1923 | 2.09 / 941.79 | 1 | 1 |
3 | 7 | 1997.76 | 24 | 10.89 | 3343 | 874 | 2.96 / 942.66 | 1 | 2 |
4 | 13 | 1698.60 | 34 | 12.23 | 2954 | 1228 | 4.19 / 943.89 | 1 | 1 |
5 | 13 | 911.52 | 34 | 13.07 | 1770 | 787 | 4.98 / 944.68 | 1 | 2 |
6 | 8 | 0.20 | 160 | 14.22 | 307 | 698 | 5.68 / 945.38 | 2 | 4 |
Average= | 5.14 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.08 | 26 | 14.08 | 481 | 176 | 0.18 / 934.14 | 1 | 2 |
2 | 3 | 961.60 | -1 | 15.17 | 0 | 0 | 0.00 / 934.14 | 1 | 2 |
3 | 3 | 1030.04 | 1 | 12.69 | 1922 | 24 | 0.20 / 934.16 | 1 | 1 |
4 | 12 | 1999.36 | 80 | 7.63 | 3176 | 1939 | 2.14 / 936.10 | 1 | 1 |
5 | 7 | 1994.68 | 24 | 10.90 | 3390 | 887 | 3.03 / 936.99 | 1 | 1 |
6 | 13 | 1688.04 | 34 | 12.27 | 2948 | 1230 | 4.26 / 938.22 | 1 | 1 |
7 | 13 | 876.44 | 34 | 13.12 | 1717 | 766 | 5.02 / 938.98 | 1 | 2 |
8 | 8 | 0.36 | 160 | 14.22 | 316 | 719 | 5.74 / 939.70 | 2 | 2 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 25 | 14.06 | 495 | 174 | 0.17 / 928.18 | 2 | 2 |
2 | 3 | 1022.68 | 1 | 12.67 | 1919 | 24 | 0.20 / 928.21 | 1 | 1 |
3 | 3 | 1019.56 | 1 | 12.46 | 1921 | 24 | 0.22 / 928.23 | 1 | 1 |
4 | 12 | 2004.16 | 80 | 7.81 | 3202 | 2001 | 2.22 / 930.23 | 1 | 1 |
5 | 7 | 1999.60 | 24 | 10.90 | 3362 | 879 | 3.10 / 931.11 | 1 | 1 |
6 | 13 | 1587.28 | 34 | 12.39 | 2803 | 1181 | 4.28 / 932.29 | 1 | 1 |
7 | 13 | 893.84 | 34 | 13.10 | 1747 | 778 | 5.06 / 933.07 | 1 | 2 |
8 | 13 | 21.32 | 34 | 14.18 | 353 | 170 | 5.23 / 933.24 | 1 | 2 |
9 | 8 | 0.24 | 160 | 14.20 | 317 | 720 | 5.95 / 933.96 | 2 | 7 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 25 | 14.10 | 482 | 170 | 0.17 / 922.50 | 2 | 2 |
2 | 12 | 2001.20 | 80 | 7.79 | 3216 | 2004 | 2.17 / 924.50 | 1 | 1 |
3 | 7 | 1996.80 | 24 | 10.90 | 3385 | 886 | 3.06 / 925.39 | 1 | 1 |
4 | 13 | 1683.44 | 34 | 12.29 | 2936 | 1227 | 4.29 / 926.61 | 1 | 1 |
5 | 13 | 777.88 | 34 | 13.22 | 1567 | 704 | 4.99 / 927.32 | 1 | 2 |
6 | 8 | 0.00 | 160 | 14.21 | 304 | 691 | 5.68 / 928.01 | 2 | 4 |
Average= | 5.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 25 | 14.11 | 469 | 165 | 0.17 / 916.80 | 1 | 2 |
2 | 12 | 2003.00 | 80 | 8.04 | 3209 | 2064 | 2.23 / 918.87 | 1 | 1 |
3 | 7 | 1998.48 | 24 | 10.90 | 3390 | 887 | 3.12 / 919.75 | 1 | 1 |
4 | 13 | 1577.88 | 34 | 12.38 | 2785 | 1172 | 4.29 / 920.93 | 1 | 1 |
5 | 13 | 760.64 | 34 | 13.23 | 1529 | 688 | 4.98 / 921.61 | 1 | 2 |
6 | 8 | -0.04 | 160 | 14.19 | 314 | 713 | 5.69 / 922.33 | 1 | 4 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.16 | 25 | 14.09 | 494 | 174 | 0.17 / 911.21 | 1 | 2 |
2 | 12 | 2003.36 | 72 | 7.89 | 3200 | 1818 | 1.99 / 913.03 | 1 | 1 |
3 | 7 | 1999.12 | 24 | 10.92 | 3371 | 883 | 2.88 / 913.92 | 1 | 2 |
4 | 13 | 1598.60 | 34 | 12.34 | 2812 | 1180 | 4.06 / 915.10 | 1 | 2 |
5 | 13 | 727.52 | 34 | 13.28 | 1481 | 669 | 4.72 / 915.76 | 1 | 2 |
6 | 13 | 26.24 | 34 | 14.19 | 353 | 170 | 4.89 / 915.93 | 1 | 2 |
7 | 8 | 0.00 | 160 | 14.21 | 309 | 703 | 5.60 / 916.64 | 2 | 2 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.12 | 24 | 14.09 | 484 | 164 | 0.16 / 905.64 | 1 | 2 |
2 | 12 | 2003.32 | 72 | 7.41 | 3136 | 1673 | 1.84 / 907.31 | 1 | 1 |
3 | 7 | 1999.80 | 24 | 10.90 | 3393 | 888 | 2.72 / 908.20 | 1 | 2 |
4 | 13 | 1803.92 | 34 | 12.10 | 3118 | 1283 | 4.01 / 909.48 | 1 | 1 |
5 | 13 | 1014.96 | 34 | 12.96 | 1934 | 852 | 4.86 / 910.33 | 1 | 2 |
6 | 8 | 0.12 | 160 | 14.23 | 311 | 708 | 5.57 / 911.04 | 2 | 3 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.52 | 25 | 14.10 | 487 | 172 | 0.17 / 900.80 | 1 | 2 |
2 | 12 | 1108.00 | 3 | 8.27 | 1950 | 48 | 0.22 / 900.84 | 1 | 1 |
3 | 12 | 1822.36 | 72 | 8.21 | 2989 | 1767 | 1.99 / 902.61 | 1 | 1 |
4 | 7 | 1816.92 | 24 | 11.00 | 3132 | 827 | 2.81 / 903.44 | 1 | 1 |
5 | 13 | 1275.80 | 34 | 12.65 | 2338 | 1006 | 3.82 / 904.44 | 1 | 1 |
6 | 13 | 257.28 | 34 | 13.84 | 725 | 341 | 4.16 / 904.78 | 1 | 2 |
7 | 8 | -0.08 | 160 | 14.20 | 303 | 688 | 4.85 / 905.47 | 2 | 7 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 25 | 14.13 | 471 | 166 | 0.17 / 895.84 | 2 | 2 |
2 | 3 | 956.20 | -1 | 15.17 | 0 | 0 | 0.00 / 895.84 | 2 | 2 |
3 | 3 | 1024.36 | 1 | 12.67 | 1933 | 24 | 0.19 / 895.86 | 1 | 1 |
4 | 12 | 1120.00 | 3 | 7.96 | 1974 | 47 | 0.24 / 895.91 | 1 | 1 |
5 | 12 | 1814.72 | 72 | 8.45 | 3002 | 1826 | 2.06 / 897.74 | 1 | 1 |
6 | 7 | 1809.00 | 24 | 11.07 | 3090 | 821 | 2.89 / 898.56 | 1 | 1 |
7 | 13 | 1360.40 | 34 | 12.60 | 2467 | 1057 | 3.94 / 899.61 | 1 | 2 |
8 | 13 | 227.28 | 34 | 13.89 | 678 | 320 | 4.26 / 899.93 | 1 | 2 |
9 | 8 | -0.08 | 160 | 14.21 | 304 | 691 | 4.95 / 900.62 | 2 | 2 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.48 | 25 | 14.15 | 473 | 167 | 0.17 / 890.09 | 1 | 2 |
2 | 12 | 2001.80 | 66 | 7.76 | 3160 | 1618 | 1.79 / 891.70 | 1 | 1 |
3 | 7 | 1997.56 | 24 | 11.01 | 3394 | 897 | 2.68 / 892.60 | 1 | 1 |
4 | 13 | 1792.40 | 34 | 12.17 | 3101 | 1283 | 3.97 / 893.88 | 1 | 1 |
5 | 13 | 994.88 | 34 | 13.02 | 1902 | 842 | 4.81 / 894.73 | 1 | 2 |
6 | 8 | 0.00 | 160 | 14.22 | 317 | 721 | 5.53 / 895.45 | 2 | 3 |
7 | 14 | 0.00 | 50 | 14.26 | 314 | 224 | 5.75 / 895.67 | 2 | 6 |
Average= | 5.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.60 | 25 | 14.14 | 474 | 168 | 0.17 / 884.39 | 2 | 2 |
2 | 12 | 2002.68 | 66 | 7.75 | 3158 | 1615 | 1.78 / 886.01 | 1 | 1 |
3 | 7 | 1998.52 | 24 | 10.99 | 3404 | 898 | 2.68 / 886.91 | 1 | 1 |
4 | 13 | 1794.04 | 34 | 12.17 | 3100 | 1283 | 3.96 / 888.19 | 1 | 1 |
5 | 13 | 1000.56 | 34 | 13.01 | 1913 | 846 | 4.81 / 889.03 | 1 | 2 |
6 | 13 | 17.48 | 34 | 14.24 | 340 | 165 | 4.97 / 889.20 | 1 | 2 |
7 | 8 | 0.16 | 160 | 14.23 | 316 | 719 | 5.69 / 889.92 | 2 | 5 |
Average= | 5.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.40 | 25 | 14.15 | 485 | 172 | 0.17 / 878.84 | 2 | 2 |
2 | 3 | 965.44 | -1 | 15.17 | 0 | 0 | 0.00 / 878.84 | 2 | 2 |
3 | 12 | 2000.56 | 66 | 8.05 | 3162 | 1680 | 1.85 / 880.52 | 1 | 1 |
4 | 7 | 1996.52 | 24 | 11.06 | 3340 | 887 | 2.74 / 881.40 | 1 | 1 |
5 | 13 | 1795.20 | 34 | 12.19 | 3102 | 1286 | 4.02 / 882.69 | 1 | 1 |
6 | 13 | 999.80 | 34 | 13.02 | 1903 | 842 | 4.87 / 883.53 | 1 | 1 |
7 | 8 | 0.28 | 160 | 14.26 | 303 | 691 | 5.56 / 884.22 | 2 | 2 |
Average= | 5.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.36 | 24 | 14.14 | 493 | 167 | 0.17 / 873.20 | 2 | 2 |
2 | 3 | 1021.96 | 1 | 12.80 | 1929 | 25 | 0.19 / 873.23 | 1 | 1 |
3 | 12 | 2003.84 | 62 | 7.97 | 3127 | 1545 | 1.74 / 874.77 | 1 | 1 |
4 | 7 | 1999.96 | 24 | 11.02 | 3394 | 898 | 2.63 / 875.67 | 1 | 1 |
5 | 13 | 1797.12 | 34 | 12.19 | 3095 | 1283 | 3.92 / 876.95 | 1 | 1 |
6 | 13 | 1009.12 | 34 | 13.00 | 1923 | 850 | 4.77 / 877.80 | 1 | 2 |
7 | 13 | 15.12 | 34 | 14.25 | 338 | 164 | 4.93 / 877.97 | 1 | 2 |
8 | 8 | 0.04 | 160 | 14.24 | 308 | 702 | 5.63 / 878.67 | 2 | 3 |
Average= | 5.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 25 | 14.18 | 471 | 167 | 0.17 / 867.84 | 2 | 2 |
2 | 12 | 2003.96 | 62 | 8.26 | 3177 | 1627 | 1.79 / 869.47 | 1 | 1 |
3 | 7 | 1999.80 | 24 | 11.05 | 3353 | 889 | 2.68 / 870.36 | 1 | 1 |
4 | 13 | 1594.52 | 34 | 12.38 | 2815 | 1185 | 3.87 / 871.54 | 1 | 1 |
5 | 13 | 922.56 | 34 | 13.07 | 1792 | 796 | 4.66 / 872.34 | 1 | 2 |
6 | 8 | 0.12 | 160 | 14.24 | 306 | 697 | 5.36 / 873.03 | 2 | 3 |
Average= | 5.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 25 | 14.16 | 473 | 167 | 0.17 / 862.45 | 2 | 2 |
2 | 12 | 2003.96 | 62 | 8.18 | 3177 | 1611 | 1.78 / 864.06 | 1 | 1 |
3 | 7 | 1999.80 | 24 | 11.07 | 3347 | 889 | 2.67 / 864.95 | 1 | 1 |
4 | 13 | 1699.12 | 34 | 12.29 | 2959 | 1236 | 3.90 / 866.18 | 1 | 1 |
5 | 13 | 910.04 | 34 | 13.09 | 1768 | 787 | 4.69 / 866.97 | 1 | 2 |
6 | 8 | 0.12 | 160 | 14.23 | 308 | 701 | 5.39 / 867.67 | 2 | 5 |
Average= | 5.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.80 | 25 | 14.18 | 479 | 170 | 0.17 / 856.97 | 1 | 2 |
2 | 3 | 971.52 | -1 | 15.12 | 0 | 0 | 0.00 / 856.97 | 1 | 2 |
3 | 12 | 2001.68 | 62 | 8.38 | 3168 | 1646 | 1.82 / 858.62 | 1 | 1 |
4 | 7 | 1997.28 | 24 | 11.09 | 3350 | 892 | 2.71 / 859.51 | 1 | 1 |
5 | 13 | 1683.28 | 34 | 12.33 | 2939 | 1232 | 3.94 / 860.74 | 1 | 1 |
6 | 13 | 987.92 | 34 | 13.01 | 1888 | 835 | 4.77 / 861.58 | 1 | 2 |
7 | 8 | -0.04 | 160 | 14.22 | 308 | 701 | 5.48 / 862.28 | 1 | 4 |
Average= | 5.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 24 | 14.19 | 469 | 160 | 0.16 / 851.48 | 2 | 2 |
2 | 3 | 1025.40 | 1 | 12.88 | 1937 | 25 | 0.18 / 851.50 | 1 | 1 |
3 | 12 | 1999.76 | 62 | 8.70 | 3173 | 1712 | 1.90 / 853.21 | 1 | 1 |
4 | 7 | 1995.08 | 24 | 11.05 | 3391 | 899 | 2.80 / 854.11 | 1 | 1 |
5 | 13 | 1677.52 | 34 | 12.32 | 2927 | 1226 | 4.02 / 855.34 | 1 | 1 |
6 | 13 | 874.80 | 34 | 13.11 | 1716 | 765 | 4.79 / 856.10 | 1 | 2 |
7 | 8 | 0.16 | 160 | 14.21 | 308 | 700 | 5.49 / 856.80 | 2 | 3 |
Average= | 5.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 25 | 14.17 | 475 | 168 | 0.17 / 845.94 | 1 | 2 |
2 | 12 | 1999.52 | 62 | 8.64 | 3193 | 1710 | 1.88 / 847.65 | 1 | 1 |
3 | 7 | 1995.04 | 24 | 11.10 | 3336 | 889 | 2.77 / 848.54 | 1 | 1 |
4 | 13 | 1571.64 | 34 | 12.44 | 2764 | 1169 | 3.94 / 849.71 | 1 | 1 |
5 | 13 | 875.60 | 34 | 13.12 | 1711 | 763 | 4.70 / 850.47 | 1 | 2 |
6 | 13 | 24.76 | 34 | 14.23 | 344 | 166 | 4.87 / 850.64 | 1 | 2 |
7 | 8 | -0.08 | 160 | 14.24 | 299 | 681 | 5.55 / 851.32 | 2 | 2 |
Average= | 5.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.48 | 25 | 14.16 | 472 | 167 | 0.17 / 840.62 | 1 | 2 |
2 | 3 | 956.12 | -1 | 15.14 | 0 | 0 | 0.00 / 840.62 | 1 | 2 |
3 | 12 | 2000.56 | 62 | 8.77 | 3189 | 1734 | 1.90 / 842.35 | 1 | 1 |
4 | 7 | 1995.88 | 24 | 11.10 | 3353 | 893 | 2.79 / 843.24 | 1 | 1 |
5 | 13 | 1574.76 | 34 | 12.44 | 2778 | 1175 | 3.97 / 844.42 | 1 | 2 |
6 | 13 | 682.48 | 34 | 13.30 | 1423 | 643 | 4.61 / 845.06 | 1 | 2 |
7 | 8 | 0.04 | 160 | 14.18 | 312 | 708 | 5.32 / 845.77 | 1 | 5 |
Average= | 5.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 25 | 14.19 | 474 | 168 | 0.17 / 835.18 | 1 | 2 |
2 | 12 | 2002.44 | 62 | 8.71 | 3202 | 1729 | 1.90 / 836.91 | 1 | 1 |
3 | 7 | 1997.72 | 24 | 11.07 | 3397 | 903 | 2.80 / 837.81 | 1 | 1 |
4 | 13 | 1558.12 | 34 | 12.46 | 2763 | 1171 | 3.97 / 838.98 | 1 | 2 |
5 | 13 | 868.40 | 34 | 13.12 | 1717 | 766 | 4.74 / 839.75 | 1 | 2 |
6 | 8 | 0.08 | 160 | 14.20 | 310 | 704 | 5.44 / 840.45 | 1 | 4 |
Average= | 5.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.44 | 25 | 14.18 | 470 | 167 | 0.17 / 829.74 | 2 | 2 |
2 | 12 | 2007.68 | 62 | 8.95 | 3214 | 1783 | 1.95 / 831.52 | 1 | 1 |
3 | 7 | 2003.56 | 24 | 11.14 | 3379 | 903 | 2.85 / 832.43 | 1 | 1 |
4 | 13 | 1568.04 | 34 | 12.45 | 2774 | 1174 | 4.03 / 833.60 | 1 | 2 |
5 | 13 | 764.44 | 34 | 13.23 | 1548 | 696 | 4.72 / 834.30 | 1 | 2 |
6 | 8 | 0.04 | 160 | 14.20 | 314 | 713 | 5.44 / 835.01 | 2 | 3 |
Average= | 5.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.08 | 23 | 14.17 | 474 | 154 | 0.15 / 824.35 | 2 | 2 |
2 | 3 | 1052.04 | 1 | 13.04 | 1987 | 26 | 0.18 / 824.38 | 1 | 1 |
3 | 3 | 1020.76 | 1 | 12.50 | 1948 | 24 | 0.20 / 824.40 | 1 | 1 |
4 | 12 | 1997.80 | 62 | 9.15 | 3213 | 1823 | 2.03 / 826.22 | 1 | 1 |
5 | 7 | 1992.12 | 24 | 11.15 | 3341 | 894 | 2.92 / 827.12 | 1 | 1 |
6 | 13 | 1451.40 | 34 | 12.58 | 2598 | 1111 | 4.03 / 828.23 | 1 | 2 |
7 | 13 | 664.80 | 34 | 13.33 | 1394 | 632 | 4.66 / 828.86 | 1 | 2 |
8 | 8 | 0.20 | 160 | 14.20 | 313 | 711 | 5.38 / 829.57 | 2 | 3 |
Average= | 5.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.96 | 23 | 14.11 | 492 | 160 | 0.16 / 818.94 | 1 | 2 |
2 | 12 | 1999.00 | 62 | 9.49 | 3270 | 1924 | 2.08 / 820.87 | 1 | 1 |
3 | 7 | 1993.76 | 24 | 11.16 | 3380 | 905 | 2.99 / 821.77 | 1 | 1 |
4 | 13 | 1553.44 | 34 | 12.48 | 2760 | 1171 | 4.16 / 822.94 | 1 | 1 |
5 | 13 | 530.32 | 34 | 13.49 | 1178 | 540 | 4.70 / 823.49 | 1 | 2 |
6 | 8 | 0.44 | 160 | 14.19 | 313 | 711 | 5.41 / 824.20 | 2 | 4 |
Average= | 5.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.04 | 25 | 14.11 | 481 | 170 | 0.17 / 813.53 | 1 | 2 |
2 | 3 | 948.40 | -1 | 15.12 | 0 | 0 | 0.00 / 813.53 | 1 | 2 |
3 | 12 | 1997.52 | 62 | 9.57 | 3255 | 1931 | 2.10 / 815.46 | 1 | 1 |
4 | 7 | 1992.04 | 24 | 11.13 | 3380 | 903 | 3.00 / 816.36 | 1 | 1 |
5 | 13 | 1423.76 | 34 | 12.56 | 2569 | 1097 | 4.10 / 817.46 | 1 | 2 |
6 | 13 | 600.12 | 34 | 13.33 | 1305 | 591 | 4.69 / 818.05 | 1 | 3 |
7 | 8 | 0.16 | 160 | 14.06 | 326 | 733 | 5.43 / 818.78 | 1 | 7 |
Average= | 5.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.88 | 24 | 14.13 | 490 | 166 | 0.17 / 808.18 | 1 | 2 |
2 | 3 | 1019.68 | 1 | 12.81 | 1947 | 25 | 0.19 / 808.21 | 1 | 1 |
3 | 12 | 2002.44 | 62 | 9.48 | 3271 | 1923 | 2.11 / 810.13 | 1 | 1 |
4 | 7 | 1997.52 | 25 | 11.14 | 3387 | 943 | 3.06 / 811.07 | 1 | 1 |
5 | 13 | 1363.76 | 34 | 12.62 | 2485 | 1066 | 4.12 / 812.14 | 1 | 2 |
6 | 13 | 449.80 | 34 | 13.47 | 1083 | 496 | 4.62 / 812.63 | 1 | 3 |
7 | 8 | -0.20 | 160 | 14.04 | 323 | 726 | 5.34 / 813.36 | 1 | 9 |
Average= | 5.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.12 | 24 | 14.12 | 489 | 166 | 0.17 / 802.83 | 1 | 2 |
2 | 12 | 2005.32 | 62 | 9.38 | 3254 | 1892 | 2.06 / 804.73 | 1 | 1 |
3 | 7 | 2000.16 | 24 | 11.13 | 3362 | 898 | 2.96 / 805.63 | 1 | 1 |
4 | 13 | 1454.16 | 34 | 12.54 | 2604 | 1110 | 4.07 / 806.74 | 1 | 2 |
5 | 13 | 522.16 | 34 | 13.40 | 1187 | 541 | 4.61 / 807.28 | 1 | 2 |
6 | 8 | 0.40 | 160 | 14.06 | 328 | 738 | 5.35 / 808.01 | 1 | 13 |
Average= | 5.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.20 | 24 | 14.10 | 498 | 169 | 0.17 / 797.37 | 1 | 2 |
2 | 12 | 2000.16 | 62 | 9.40 | 3266 | 1903 | 2.07 / 799.27 | 1 | 1 |
3 | 7 | 1995.04 | 24 | 11.14 | 3381 | 904 | 2.98 / 800.18 | 1 | 1 |
4 | 13 | 1550.16 | 34 | 12.45 | 2751 | 1164 | 4.14 / 801.34 | 1 | 2 |
5 | 13 | 596.68 | 34 | 13.33 | 1302 | 590 | 4.73 / 801.93 | 1 | 3 |
6 | 8 | -0.12 | 160 | 14.05 | 329 | 740 | 5.47 / 802.67 | 1 | 8 |
Average= | 5.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.16 | 24 | 14.21 | 468 | 160 | 0.16 / 792.07 | 1 | 2 |
2 | 12 | 1998.56 | 62 | 9.15 | 3221 | 1827 | 1.99 / 793.89 | 1 | 1 |
3 | 7 | 1993.52 | 24 | 11.16 | 3344 | 896 | 2.88 / 794.79 | 1 | 1 |
4 | 13 | 1348.16 | 34 | 12.63 | 2440 | 1048 | 3.93 / 795.84 | 1 | 2 |
5 | 13 | 649.76 | 34 | 13.29 | 1367 | 618 | 4.55 / 796.45 | 1 | 2 |
6 | 8 | -0.04 | 160 | 14.06 | 331 | 745 | 5.29 / 797.20 | 1 | 8 |
Average= | 5.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.88 | 25 | 14.13 | 492 | 174 | 0.17 / 786.68 | 1 | 2 |
2 | 12 | 2000.48 | 62 | 9.12 | 3234 | 1829 | 2.00 / 788.50 | 1 | 1 |
3 | 7 | 1995.76 | 24 | 11.17 | 3352 | 899 | 2.90 / 789.40 | 1 | 1 |
4 | 13 | 1567.80 | 34 | 12.44 | 2767 | 1170 | 4.07 / 790.57 | 1 | 2 |
5 | 13 | 660.76 | 34 | 13.30 | 1391 | 629 | 4.70 / 791.20 | 1 | 2 |
6 | 8 | -0.16 | 160 | 14.16 | 311 | 705 | 5.40 / 791.91 | 1 | 3 |
Average= | 5.08 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.64 | 25 | 14.20 | 474 | 168 | 0.17 / 781.21 | 2 | 2 |
2 | 3 | 971.88 | -1 | 15.16 | 0 | 0 | 0.00 / 781.21 | 2 | 2 |
3 | 3 | 1042.80 | 1 | 12.92 | 1939 | 25 | 0.19 / 781.24 | 1 | 1 |
4 | 12 | 1997.12 | 62 | 8.87 | 3188 | 1753 | 1.95 / 782.99 | 1 | 1 |
5 | 7 | 1991.40 | 24 | 11.12 | 3396 | 906 | 2.85 / 783.90 | 1 | 1 |
6 | 13 | 1652.56 | 34 | 12.35 | 2897 | 1216 | 4.07 / 785.11 | 1 | 1 |
7 | 13 | 721.72 | 34 | 13.24 | 1491 | 671 | 4.74 / 785.78 | 1 | 2 |
8 | 8 | -0.08 | 160 | 14.14 | 317 | 717 | 5.46 / 786.50 | 1 | 4 |
Average= | 5.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.08 | 25 | 14.22 | 463 | 165 | 0.16 / 775.72 | 2 | 2 |
2 | 12 | 1999.72 | 62 | 8.62 | 3139 | 1678 | 1.84 / 777.40 | 1 | 1 |
3 | 7 | 1994.76 | 24 | 11.17 | 3386 | 908 | 2.75 / 778.31 | 1 | 1 |
4 | 13 | 1781.32 | 34 | 12.21 | 3093 | 1284 | 4.03 / 779.59 | 1 | 2 |
5 | 13 | 838.64 | 34 | 13.14 | 1671 | 747 | 4.78 / 780.34 | 1 | 2 |
6 | 8 | 0.28 | 160 | 14.21 | 311 | 707 | 5.49 / 781.04 | 2 | 2 |
Average= | 5.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 25 | 14.25 | 458 | 163 | 0.16 / 770.08 | 2 | 2 |
2 | 12 | 2004.52 | 62 | 8.51 | 3147 | 1660 | 1.82 / 771.74 | 1 | 1 |
3 | 7 | 2000.60 | 24 | 11.18 | 3388 | 909 | 2.73 / 772.65 | 1 | 1 |
4 | 13 | 1801.32 | 34 | 12.20 | 3110 | 1290 | 4.02 / 773.94 | 1 | 1 |
5 | 13 | 875.88 | 34 | 13.14 | 1710 | 764 | 4.79 / 774.71 | 1 | 1 |
6 | 13 | 27.76 | 34 | 14.24 | 340 | 165 | 4.95 / 774.87 | 1 | 2 |
7 | 8 | -0.12 | 160 | 14.23 | 301 | 685 | 5.64 / 775.56 | 2 | 2 |
Average= | 5.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.88 | 25 | 14.23 | 457 | 163 | 0.16 / 764.52 | 2 | 2 |
2 | 3 | 957.60 | -1 | 15.17 | 0 | 0 | 0.00 / 764.52 | 2 | 2 |
3 | 3 | 1024.04 | 1 | 12.70 | 1929 | 24 | 0.19 / 764.54 | 1 | 1 |
4 | 12 | 2001.68 | 62 | 8.90 | 3173 | 1751 | 1.94 / 766.29 | 1 | 1 |
5 | 7 | 1997.28 | 25 | 11.18 | 3406 | 952 | 2.89 / 767.25 | 1 | 1 |
6 | 13 | 1586.88 | 34 | 12.42 | 2800 | 1182 | 4.07 / 768.43 | 1 | 1 |
7 | 13 | 680.20 | 34 | 13.34 | 1407 | 638 | 4.71 / 769.07 | 1 | 2 |
8 | 13 | 36.72 | 34 | 14.20 | 367 | 177 | 4.89 / 769.24 | 1 | 2 |
9 | 8 | -0.12 | 160 | 14.22 | 297 | 676 | 5.56 / 769.92 | 1 | 4 |
Average= | 5.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.80 | 26 | 14.21 | 485 | 179 | 0.18 / 758.97 | 2 | 2 |
2 | 12 | 2000.80 | 62 | 8.66 | 3140 | 1686 | 1.87 / 760.65 | 1 | 1 |
3 | 7 | 1996.56 | 24 | 11.15 | 3390 | 907 | 2.77 / 761.56 | 1 | 1 |
4 | 13 | 1575.24 | 34 | 12.42 | 2782 | 1175 | 3.95 / 762.73 | 1 | 1 |
5 | 13 | 903.52 | 34 | 13.08 | 1765 | 785 | 4.73 / 763.52 | 1 | 2 |
6 | 13 | 13.72 | 34 | 14.24 | 333 | 161 | 4.89 / 763.68 | 1 | 2 |
7 | 8 | 0.04 | 160 | 14.20 | 298 | 677 | 5.57 / 764.36 | 2 | 3 |
Average= | 5.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 25 | 14.21 | 489 | 174 | 0.17 / 753.64 | 1 | 2 |
2 | 3 | 1019.76 | 1 | 12.63 | 1916 | 24 | 0.20 / 753.66 | 1 | 1 |
3 | 12 | 2000.68 | 62 | 8.70 | 3114 | 1680 | 1.88 / 755.34 | 1 | 1 |
4 | 7 | 1996.32 | 25 | 11.22 | 3389 | 951 | 2.83 / 756.29 | 1 | 1 |
5 | 13 | 1490.56 | 34 | 12.50 | 2659 | 1130 | 3.96 / 757.42 | 1 | 1 |
6 | 13 | 714.48 | 34 | 13.30 | 1460 | 660 | 4.62 / 758.08 | 1 | 2 |
7 | 8 | -0.20 | 160 | 14.20 | 310 | 704 | 5.32 / 758.79 | 2 | 2 |
Average= | 5.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.28 | 25 | 14.20 | 497 | 176 | 0.18 / 748.10 | 1 | 2 |
2 | 3 | 964.64 | -1 | 15.20 | 0 | 0 | 0.00 / 748.10 | 1 | 2 |
3 | 3 | 1033.04 | 1 | 12.73 | 1904 | 24 | 0.20 / 748.13 | 1 | 1 |
4 | 12 | 2005.12 | 62 | 8.62 | 3115 | 1665 | 1.87 / 749.79 | 1 | 1 |
5 | 7 | 2000.88 | 24 | 11.17 | 3373 | 904 | 2.77 / 750.69 | 1 | 1 |
6 | 13 | 1686.36 | 34 | 12.30 | 2950 | 1234 | 4.00 / 751.93 | 1 | 1 |
7 | 13 | 988.08 | 34 | 13.01 | 1886 | 834 | 4.84 / 752.76 | 1 | 2 |
8 | 8 | 0.12 | 160 | 14.22 | 308 | 701 | 5.54 / 753.46 | 2 | 2 |
Average= | 5.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 25 | 14.20 | 489 | 174 | 0.17 / 742.50 | 1 | 2 |
2 | 3 | 1025.84 | 1 | 12.69 | 1919 | 24 | 0.20 / 742.52 | 1 | 1 |
3 | 12 | 2001.16 | 62 | 8.84 | 3132 | 1717 | 1.91 / 744.24 | 1 | 1 |
4 | 7 | 1996.96 | 24 | 11.17 | 3413 | 915 | 2.83 / 745.15 | 1 | 1 |
5 | 13 | 1583.92 | 34 | 12.41 | 2803 | 1183 | 4.01 / 746.34 | 1 | 3 |
6 | 13 | 793.96 | 34 | 13.23 | 1594 | 717 | 4.73 / 747.05 | 1 | 2 |
7 | 13 | 13.12 | 34 | 14.24 | 336 | 163 | 4.89 / 747.21 | 1 | 2 |
8 | 8 | -0.04 | 160 | 14.18 | 313 | 710 | 5.60 / 747.92 | 2 | 6 |
Average= | 5.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 25 | 14.22 | 476 | 169 | 0.17 / 737.15 | 2 | 2 |
2 | 12 | 2006.92 | 62 | 8.84 | 3129 | 1715 | 1.88 / 738.87 | 1 | 1 |
3 | 7 | 2002.84 | 24 | 11.20 | 3384 | 910 | 2.79 / 739.78 | 1 | 1 |
4 | 13 | 1585.04 | 34 | 12.42 | 2803 | 1184 | 3.98 / 740.96 | 1 | 4 |
5 | 13 | 701.08 | 34 | 13.32 | 1438 | 651 | 4.63 / 741.61 | 1 | 2 |
6 | 8 | 0.12 | 160 | 14.18 | 314 | 712 | 5.34 / 742.32 | 1 | 2 |
Average= | 5.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.60 | 25 | 14.21 | 490 | 174 | 0.17 / 731.70 | 2 | 2 |
2 | 12 | 2004.84 | 55 | 8.76 | 3072 | 1480 | 1.65 / 733.18 | 1 | 1 |
3 | 7 | 2001.00 | 24 | 11.24 | 3361 | 907 | 2.56 / 734.09 | 1 | 1 |
4 | 13 | 1793.00 | 34 | 12.19 | 3093 | 1282 | 3.84 / 735.37 | 1 | 2 |
5 | 13 | 1087.08 | 34 | 12.90 | 2045 | 897 | 4.74 / 736.27 | 1 | 2 |
6 | 8 | 0.04 | 160 | 14.19 | 314 | 713 | 5.45 / 736.98 | 2 | 3 |
Average= | 5.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 25 | 14.17 | 504 | 179 | 0.18 / 726.08 | 1 | 2 |
2 | 12 | 2001.92 | 55 | 8.77 | 3118 | 1504 | 1.68 / 727.58 | 1 | 1 |
3 | 7 | 1997.32 | 24 | 11.20 | 3370 | 906 | 2.59 / 728.49 | 1 | 1 |
4 | 13 | 1794.00 | 34 | 12.19 | 3095 | 1283 | 3.87 / 729.77 | 1 | 2 |
5 | 13 | 1083.20 | 34 | 12.91 | 2038 | 895 | 4.77 / 730.66 | 1 | 2 |
6 | 13 | 20.56 | 34 | 14.24 | 339 | 164 | 4.93 / 730.83 | 1 | 2 |
7 | 8 | 0.20 | 160 | 14.20 | 309 | 702 | 5.63 / 731.53 | 2 | 2 |
Average= | 5.05 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 25 | 14.22 | 468 | 166 | 0.17 / 720.80 | 1 | 2 |
2 | 3 | 960.60 | -1 | 15.20 | 0 | 0 | 0.00 / 720.80 | 1 | 2 |
3 | 3 | 1028.04 | 1 | 12.56 | 1909 | 24 | 0.19 / 720.82 | 1 | 1 |
4 | 12 | 2005.12 | 55 | 9.03 | 3119 | 1549 | 1.74 / 722.37 | 1 | 1 |
5 | 7 | 2001.24 | 24 | 11.24 | 3365 | 908 | 2.65 / 723.28 | 1 | 1 |
6 | 13 | 1596.52 | 34 | 12.41 | 2813 | 1187 | 3.83 / 724.47 | 1 | 2 |
7 | 13 | 825.08 | 34 | 13.20 | 1627 | 730 | 4.56 / 725.20 | 1 | 2 |
8 | 8 | 0.00 | 160 | 14.19 | 308 | 699 | 5.26 / 725.90 | 2 | 2 |
Average= | 5.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.24 | 25 | 14.19 | 493 | 175 | 0.17 / 715.40 | 1 | 2 |
2 | 12 | 2004.52 | 53 | 8.86 | 3090 | 1451 | 1.63 / 716.85 | 1 | 1 |
3 | 7 | 2000.48 | 24 | 11.25 | 3350 | 904 | 2.53 / 717.76 | 1 | 1 |
4 | 13 | 1704.44 | 34 | 12.29 | 2966 | 1239 | 3.77 / 719.00 | 1 | 1 |
5 | 13 | 919.56 | 34 | 13.08 | 1779 | 791 | 4.56 / 719.79 | 1 | 2 |
6 | 13 | 17.44 | 34 | 14.25 | 330 | 160 | 4.72 / 719.95 | 1 | 2 |
7 | 8 | -0.04 | 160 | 14.19 | 302 | 686 | 5.41 / 720.63 | 2 | 8 |
Average= | 5.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.68 | 25 | 14.20 | 484 | 172 | 0.17 / 710.16 | 1 | 2 |
2 | 3 | 1022.40 | 1 | 12.32 | 1922 | 24 | 0.20 / 710.18 | 1 | 1 |
3 | 12 | 2001.96 | 53 | 9.24 | 3127 | 1531 | 1.73 / 711.71 | 1 | 1 |
4 | 7 | 1997.28 | 24 | 11.29 | 3356 | 909 | 2.64 / 712.62 | 1 | 1 |
5 | 13 | 1589.04 | 34 | 12.40 | 2803 | 1182 | 3.82 / 713.80 | 1 | 1 |
6 | 13 | 801.44 | 34 | 13.22 | 1596 | 717 | 4.54 / 714.52 | 1 | 1 |
7 | 8 | 0.40 | 160 | 14.18 | 311 | 706 | 5.24 / 715.23 | 2 | 3 |
Average= | 5.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 25 | 14.16 | 492 | 174 | 0.17 / 704.90 | 1 | 2 |
2 | 12 | 2005.28 | 53 | 9.26 | 3113 | 1528 | 1.70 / 706.43 | 1 | 1 |
3 | 7 | 2001.12 | 24 | 11.24 | 3383 | 913 | 2.61 / 707.34 | 1 | 1 |
4 | 13 | 1692.84 | 34 | 12.30 | 2958 | 1237 | 3.85 / 708.58 | 1 | 1 |
5 | 13 | 785.36 | 34 | 13.23 | 1568 | 705 | 4.56 / 709.28 | 1 | 1 |
6 | 8 | 0.32 | 160 | 14.18 | 311 | 706 | 5.26 / 709.99 | 1 | 6 |
Average= | 5.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 25 | 14.22 | 484 | 172 | 0.17 / 699.67 | 1 | 2 |
2 | 3 | 960.16 | -1 | 15.20 | 0 | 0 | 0.00 / 699.67 | 1 | 2 |
3 | 3 | 1032.64 | 1 | 12.47 | 1920 | 24 | 0.20 / 699.70 | 1 | 1 |
4 | 12 | 2000.96 | 45 | 9.36 | 3118 | 1313 | 1.51 / 701.01 | 1 | 1 |
5 | 7 | 1997.28 | 24 | 11.33 | 3366 | 915 | 2.42 / 701.93 | 1 | 1 |
6 | 13 | 1795.40 | 34 | 12.20 | 3108 | 1289 | 3.71 / 703.21 | 1 | 1 |
7 | 13 | 929.68 | 34 | 13.07 | 1795 | 798 | 4.51 / 704.01 | 1 | 2 |
8 | 8 | -0.32 | 160 | 14.17 | 314 | 712 | 5.22 / 704.72 | 2 | 7 |
Average= | 5.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.20 | 25 | 14.21 | 508 | 180 | 0.18 / 694.33 | 2 | 2 |
2 | 12 | 2002.92 | 45 | 9.18 | 3086 | 1275 | 1.46 / 695.60 | 1 | 1 |
3 | 7 | 1999.20 | 24 | 11.31 | 3367 | 914 | 2.37 / 696.52 | 1 | 1 |
4 | 13 | 1696.20 | 34 | 12.30 | 2967 | 1241 | 3.61 / 697.76 | 1 | 1 |
5 | 13 | 1030.08 | 34 | 12.96 | 1955 | 861 | 4.47 / 698.62 | 1 | 2 |
6 | 13 | 14.08 | 34 | 14.24 | 336 | 163 | 4.63 / 698.78 | 1 | 2 |
7 | 8 | -0.24 | 160 | 14.16 | 317 | 718 | 5.35 / 699.50 | 2 | 4 |
Average= | 5.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.20 | 25 | 14.21 | 484 | 172 | 0.17 / 689.14 | 2 | 2 |
2 | 12 | 2004.16 | 45 | 9.57 | 3157 | 1360 | 1.53 / 690.50 | 1 | 1 |
3 | 7 | 2000.20 | 24 | 11.30 | 3391 | 920 | 2.45 / 691.42 | 1 | 1 |
4 | 13 | 1683.40 | 34 | 12.32 | 2940 | 1232 | 3.68 / 692.65 | 1 | 2 |
5 | 13 | 907.20 | 34 | 13.10 | 1761 | 784 | 4.47 / 693.44 | 1 | 2 |
6 | 8 | 0.20 | 160 | 14.18 | 313 | 710 | 5.18 / 694.15 | 2 | 2 |
Average= | 5.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 25 | 14.24 | 479 | 171 | 0.17 / 683.97 | 2 | 2 |
2 | 12 | 2001.00 | 45 | 9.71 | 3170 | 1385 | 1.56 / 685.35 | 1 | 1 |
3 | 7 | 1996.48 | 24 | 11.26 | 3382 | 914 | 2.47 / 686.27 | 1 | 1 |
4 | 13 | 1670.32 | 34 | 12.30 | 2931 | 1226 | 3.70 / 687.49 | 1 | 2 |
5 | 13 | 883.84 | 34 | 13.09 | 1733 | 771 | 4.47 / 688.26 | 1 | 2 |
6 | 8 | 0.04 | 160 | 14.16 | 312 | 707 | 5.17 / 688.97 | 2 | 2 |
Average= | 5.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 25 | 14.24 | 474 | 169 | 0.17 / 678.82 | 2 | 2 |
2 | 12 | 2000.16 | 45 | 9.45 | 3135 | 1333 | 1.50 / 680.16 | 1 | 1 |
3 | 7 | 1995.88 | 24 | 11.26 | 3365 | 909 | 2.41 / 681.07 | 1 | 1 |
4 | 13 | 1691.84 | 34 | 12.31 | 2957 | 1238 | 3.65 / 682.30 | 1 | 1 |
5 | 13 | 921.04 | 34 | 13.07 | 1790 | 795 | 4.44 / 683.10 | 1 | 2 |
6 | 8 | 0.08 | 160 | 14.20 | 307 | 698 | 5.14 / 683.80 | 2 | 2 |
Average= | 5.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.48 | 25 | 14.26 | 469 | 167 | 0.17 / 673.42 | 2 | 2 |
2 | 3 | 956.24 | -1 | 15.21 | 0 | 0 | 0.00 / 673.42 | 2 | 2 |
3 | 3 | 1022.80 | 1 | 11.83 | 1928 | 23 | 0.19 / 673.44 | 1 | 1 |
4 | 12 | 2003.96 | 45 | 9.52 | 3180 | 1362 | 1.55 / 674.80 | 1 | 1 |
5 | 7 | 2000.24 | 24 | 11.34 | 3398 | 925 | 2.48 / 675.73 | 1 | 1 |
6 | 13 | 1703.40 | 34 | 12.35 | 2969 | 1247 | 3.72 / 676.98 | 1 | 1 |
7 | 13 | 923.52 | 34 | 13.11 | 1786 | 796 | 4.52 / 677.77 | 1 | 2 |
8 | 13 | 40.48 | 34 | 14.23 | 375 | 181 | 4.70 / 677.95 | 1 | 2 |
9 | 8 | -0.04 | 160 | 14.20 | 309 | 702 | 5.40 / 678.66 | 2 | 3 |
Average= | 5.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.08 | 24 | 14.27 | 473 | 162 | 0.16 / 668.05 | 2 | 2 |
2 | 3 | 1064.24 | 2 | 12.53 | 1978 | 50 | 0.21 / 668.10 | 1 | 1 |
3 | 12 | 2001.72 | 45 | 9.71 | 3177 | 1388 | 1.60 / 669.49 | 1 | 2 |
4 | 7 | 1997.44 | 24 | 11.33 | 3350 | 911 | 2.51 / 670.40 | 2 | 1 |
5 | 13 | 1687.64 | 34 | 12.37 | 2949 | 1240 | 3.75 / 671.64 | 1 | 1 |
6 | 13 | 797.00 | 34 | 13.25 | 1596 | 719 | 4.47 / 672.36 | 1 | 2 |
7 | 13 | 42.76 | 34 | 14.20 | 380 | 183 | 4.65 / 672.54 | 1 | 2 |
8 | 8 | 0.16 | 160 | 14.19 | 312 | 708 | 5.36 / 673.25 | 2 | 4 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.36 | 24 | 14.21 | 468 | 160 | 0.16 / 662.94 | 1 | 2 |
2 | 12 | 2003.40 | 45 | 10.21 | 3270 | 1502 | 1.66 / 664.44 | 1 | 1 |
3 | 7 | 1999.04 | 24 | 11.29 | 3384 | 917 | 2.58 / 665.36 | 1 | 1 |
4 | 13 | 1588.92 | 34 | 12.45 | 2804 | 1187 | 3.77 / 666.55 | 1 | 2 |
5 | 13 | 696.72 | 34 | 13.35 | 1431 | 650 | 4.42 / 667.20 | 1 | 2 |
6 | 8 | 0.08 | 160 | 14.20 | 306 | 695 | 5.11 / 667.89 | 2 | 4 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.68 | 23 | 14.15 | 496 | 161 | 0.16 / 657.75 | 1 | 2 |
2 | 3 | 1034.12 | 1 | 12.50 | 1950 | 24 | 0.19 / 657.78 | 1 | 1 |
3 | 12 | 2001.60 | 45 | 10.38 | 3282 | 1533 | 1.72 / 659.31 | 1 | 1 |
4 | 7 | 1996.84 | 24 | 11.32 | 3406 | 925 | 2.64 / 660.23 | 1 | 1 |
5 | 13 | 1563.88 | 34 | 12.45 | 2782 | 1178 | 3.82 / 661.41 | 1 | 2 |
6 | 13 | 666.36 | 34 | 13.28 | 1404 | 634 | 4.46 / 662.04 | 1 | 2 |
7 | 8 | 0.00 | 160 | 14.09 | 326 | 735 | 5.19 / 662.78 | 1 | 4 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 23 | 14.15 | 501 | 163 | 0.16 / 652.56 | 1 | 1 |
2 | 12 | 2004.44 | 45 | 10.37 | 3285 | 1533 | 1.70 / 654.09 | 1 | 1 |
3 | 7 | 2000.32 | 24 | 11.30 | 3342 | 906 | 2.60 / 655.00 | 1 | 1 |
4 | 13 | 1468.00 | 34 | 12.53 | 2636 | 1123 | 3.73 / 656.12 | 1 | 1 |
5 | 13 | 784.24 | 34 | 13.15 | 1599 | 715 | 4.44 / 656.84 | 1 | 2 |
6 | 8 | 0.08 | 160 | 14.03 | 335 | 752 | 5.19 / 657.59 | 1 | 9 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.00 | 23 | 14.12 | 495 | 161 | 0.16 / 647.45 | 1 | 2 |
2 | 3 | 973.16 | -1 | 15.16 | 0 | 0 | 0.00 / 647.45 | 1 | 2 |
3 | 3 | 1023.60 | 1 | 11.94 | 1944 | 23 | 0.18 / 647.48 | 1 | 1 |
4 | 12 | 2004.16 | 45 | 10.53 | 3276 | 1552 | 1.74 / 649.03 | 1 | 1 |
5 | 7 | 1999.76 | 24 | 11.34 | 3359 | 914 | 2.65 / 649.94 | 1 | 1 |
6 | 13 | 1391.88 | 34 | 12.59 | 2528 | 1082 | 3.73 / 651.03 | 1 | 4 |
7 | 13 | 605.80 | 34 | 13.31 | 1330 | 602 | 4.33 / 651.63 | 1 | 2 |
8 | 8 | -0.12 | 160 | 14.00 | 343 | 768 | 5.10 / 652.40 | 1 | 6 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 23 | 14.15 | 496 | 161 | 0.16 / 642.25 | 1 | 2 |
2 | 3 | 1026.12 | 1 | 12.08 | 1958 | 24 | 0.19 / 642.27 | 1 | 1 |
3 | 12 | 2005.44 | 45 | 10.53 | 3280 | 1554 | 1.74 / 643.82 | 1 | 2 |
4 | 7 | 2001.64 | 24 | 11.36 | 3365 | 917 | 2.66 / 644.74 | 2 | 1 |
5 | 13 | 1562.36 | 34 | 12.44 | 2776 | 1174 | 3.83 / 645.92 | 1 | 2 |
6 | 13 | 650.64 | 34 | 13.25 | 1398 | 630 | 4.46 / 646.55 | 1 | 2 |
7 | 8 | 0.20 | 160 | 14.01 | 334 | 749 | 5.21 / 647.29 | 1 | 5 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.76 | 23 | 14.15 | 500 | 163 | 0.16 / 637.09 | 1 | 2 |
2 | 3 | 967.64 | -1 | 15.16 | 0 | 0 | 0.00 / 637.09 | 1 | 2 |
3 | 3 | 1038.52 | 1 | 12.26 | 1964 | 24 | 0.19 / 637.11 | 1 | 1 |
4 | 12 | 2002.52 | 45 | 10.53 | 3273 | 1551 | 1.74 / 638.66 | 1 | 2 |
5 | 7 | 1998.08 | 24 | 11.33 | 3341 | 908 | 2.65 / 639.57 | 2 | 2 |
6 | 13 | 1471.28 | 34 | 12.51 | 2632 | 1119 | 3.77 / 640.69 | 1 | 4 |
7 | 13 | 679.56 | 34 | 13.23 | 1438 | 647 | 4.41 / 641.34 | 1 | 2 |
8 | 8 | 0.00 | 160 | 14.02 | 333 | 747 | 5.16 / 642.08 | 1 | 5 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 23 | 14.15 | 488 | 159 | 0.16 / 631.39 | 1 | 2 |
2 | 12 | 2004.24 | 45 | 10.52 | 3290 | 1557 | 1.72 / 632.94 | 1 | 1 |
3 | 7 | 2000.28 | 24 | 11.34 | 3358 | 914 | 2.63 / 633.86 | 1 | 1 |
4 | 13 | 1587.88 | 34 | 12.40 | 2815 | 1187 | 3.82 / 635.04 | 1 | 1 |
5 | 13 | 771.76 | 34 | 13.13 | 1585 | 708 | 4.52 / 635.75 | 1 | 2 |
6 | 13 | 25.20 | 34 | 14.08 | 380 | 182 | 4.71 / 635.93 | 1 | 3 |
7 | 8 | -0.40 | 160 | 13.99 | 338 | 757 | 5.46 / 636.69 | 1 | 7 |
8 | 14 | -0.40 | 50 | 14.04 | 335 | 235 | 5.70 / 636.93 | 1 | 6 |
Average= | 5.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 23 | 14.15 | 501 | 163 | 0.16 / 626.06 | 1 | 2 |
2 | 12 | 1999.36 | 45 | 10.55 | 3292 | 1563 | 1.73 / 627.62 | 1 | 2 |
3 | 7 | 1994.36 | 24 | 11.36 | 3352 | 914 | 2.64 / 628.53 | 2 | 1 |
4 | 13 | 1656.16 | 34 | 12.36 | 2901 | 1219 | 3.86 / 629.75 | 1 | 2 |
5 | 13 | 826.12 | 34 | 13.09 | 1666 | 741 | 4.60 / 630.49 | 1 | 3 |
6 | 8 | 0.08 | 160 | 14.03 | 327 | 734 | 5.33 / 631.23 | 1 | 3 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.24 | 24 | 14.14 | 482 | 164 | 0.16 / 620.68 | 1 | 2 |
2 | 3 | 954.80 | -1 | 15.16 | 0 | 0 | 0.00 / 620.68 | 1 | 2 |
3 | 12 | 2000.04 | 45 | 10.56 | 3275 | 1556 | 1.72 / 622.23 | 1 | 2 |
4 | 7 | 1995.60 | 24 | 11.31 | 3391 | 920 | 2.64 / 623.15 | 2 | 1 |
5 | 13 | 1450.68 | 34 | 12.51 | 2609 | 1110 | 3.75 / 624.26 | 1 | 3 |
6 | 13 | 759.08 | 34 | 13.14 | 1562 | 698 | 4.45 / 624.96 | 1 | 2 |
7 | 13 | 18.24 | 34 | 14.08 | 371 | 178 | 4.63 / 625.14 | 1 | 3 |
8 | 8 | -0.12 | 160 | 13.96 | 338 | 755 | 5.38 / 625.89 | 1 | 3 |
Average= | 5.01 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 24 | 14.21 | 479 | 163 | 0.16 / 615.62 | 1 | 2 |
2 | 12 | 1998.60 | 45 | 10.64 | 3262 | 1562 | 1.73 / 617.19 | 1 | 2 |
3 | 7 | 1993.20 | 24 | 11.32 | 3398 | 923 | 2.65 / 618.11 | 2 | 1 |
4 | 13 | 1369.12 | 34 | 12.58 | 2495 | 1067 | 3.72 / 619.18 | 1 | 2 |
5 | 13 | 575.88 | 34 | 13.33 | 1278 | 579 | 4.29 / 619.76 | 1 | 2 |
6 | 8 | -0.08 | 160 | 14.00 | 338 | 757 | 5.05 / 620.51 | 1 | 7 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.32 | 23 | 14.14 | 493 | 160 | 0.16 / 610.44 | 1 | 2 |
2 | 12 | 1999.52 | 45 | 10.64 | 3279 | 1570 | 1.73 / 612.01 | 1 | 2 |
3 | 7 | 1994.76 | 24 | 11.31 | 3400 | 923 | 2.65 / 612.94 | 2 | 1 |
4 | 13 | 1557.60 | 34 | 12.41 | 2774 | 1170 | 3.82 / 614.11 | 1 | 4 |
5 | 13 | 650.64 | 34 | 13.27 | 1381 | 623 | 4.45 / 614.73 | 1 | 2 |
6 | 8 | -0.12 | 160 | 14.07 | 324 | 729 | 5.18 / 615.46 | 1 | 3 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 25 | 14.11 | 490 | 173 | 0.17 / 605.34 | 1 | 2 |
2 | 3 | 919.68 | -2 | 15.17 | 0 | 0 | 0.00 / 605.34 | 1 | 2 |
3 | 12 | 2001.72 | 45 | 10.62 | 3297 | 1576 | 1.75 / 606.92 | 1 | 1 |
4 | 7 | 1996.92 | 24 | 11.30 | 3404 | 923 | 2.67 / 607.84 | 1 | 1 |
5 | 13 | 1541.16 | 34 | 12.40 | 2743 | 1156 | 3.83 / 609.00 | 1 | 2 |
6 | 13 | 528.60 | 34 | 13.38 | 1196 | 544 | 4.37 / 609.54 | 1 | 2 |
7 | 8 | -0.08 | 160 | 14.03 | 330 | 741 | 5.11 / 610.28 | 1 | 6 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.60 | 24 | 14.17 | 480 | 163 | 0.16 / 599.98 | 1 | 2 |
2 | 3 | 1034.20 | 1 | 12.34 | 1934 | 24 | 0.19 / 600.00 | 1 | 1 |
3 | 3 | 1021.48 | 1 | 12.12 | 1957 | 24 | 0.21 / 600.02 | 1 | 1 |
4 | 12 | 2002.12 | 45 | 10.64 | 3297 | 1579 | 1.79 / 601.60 | 1 | 2 |
5 | 7 | 1997.76 | 24 | 11.29 | 3393 | 919 | 2.71 / 602.52 | 2 | 1 |
6 | 13 | 1367.52 | 34 | 12.55 | 2482 | 1059 | 3.77 / 603.58 | 1 | 3 |
7 | 13 | 688.12 | 34 | 13.20 | 1443 | 648 | 4.42 / 604.23 | 1 | 2 |
8 | 13 | 27.48 | 34 | 14.04 | 389 | 186 | 4.60 / 604.42 | 1 | 3 |
9 | 8 | -0.20 | 160 | 13.94 | 339 | 756 | 5.36 / 605.17 | 1 | 6 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.52 | 24 | 14.17 | 478 | 163 | 0.16 / 594.83 | 1 | 2 |
2 | 12 | 1999.96 | 45 | 10.58 | 3278 | 1561 | 1.72 / 596.39 | 1 | 1 |
3 | 7 | 1994.96 | 24 | 11.24 | 3390 | 914 | 2.64 / 597.30 | 1 | 1 |
4 | 13 | 1573.48 | 34 | 12.35 | 2794 | 1173 | 3.81 / 598.48 | 1 | 3 |
5 | 13 | 656.28 | 34 | 13.25 | 1386 | 624 | 4.44 / 599.10 | 1 | 2 |
6 | 8 | 0.20 | 160 | 14.07 | 316 | 711 | 5.15 / 599.81 | 1 | 7 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.00 | 24 | 14.14 | 481 | 163 | 0.16 / 589.47 | 1 | 2 |
2 | 12 | 1999.44 | 45 | 10.65 | 3304 | 1583 | 1.75 / 591.05 | 1 | 2 |
3 | 7 | 1994.40 | 24 | 11.25 | 3391 | 916 | 2.66 / 591.97 | 2 | 1 |
4 | 13 | 1452.24 | 34 | 12.45 | 2609 | 1104 | 3.77 / 593.07 | 1 | 2 |
5 | 13 | 765.08 | 34 | 13.13 | 1553 | 693 | 4.46 / 593.76 | 1 | 2 |
6 | 13 | 20.56 | 34 | 14.09 | 365 | 175 | 4.63 / 593.94 | 1 | 2 |
7 | 8 | -0.16 | 160 | 13.96 | 326 | 728 | 5.36 / 594.67 | 1 | 5 |
Average= | 5.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 25 | 14.18 | 481 | 171 | 0.17 / 584.37 | 1 | 2 |
2 | 3 | 914.80 | -2 | 15.18 | 0 | 0 | 0.00 / 584.37 | 1 | 2 |
3 | 3 | 1023.12 | 1 | 11.62 | 1933 | 22 | 0.19 / 584.39 | 1 | 1 |
4 | 12 | 2002.48 | 45 | 10.65 | 3285 | 1574 | 1.77 / 585.97 | 1 | 1 |
5 | 7 | 1998.16 | 24 | 11.29 | 3372 | 914 | 2.68 / 586.88 | 1 | 1 |
6 | 13 | 1540.00 | 34 | 12.36 | 2750 | 1156 | 3.84 / 588.04 | 1 | 2 |
7 | 13 | 509.08 | 34 | 13.38 | 1169 | 532 | 4.37 / 588.57 | 1 | 2 |
8 | 8 | -0.16 | 160 | 13.99 | 329 | 736 | 5.10 / 589.30 | 1 | 11 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.36 | 25 | 14.19 | 486 | 172 | 0.17 / 579.17 | 2 | 2 |
2 | 3 | 972.40 | -1 | 15.19 | 0 | 0 | 0.00 / 579.17 | 2 | 2 |
3 | 3 | 1030.28 | 1 | 11.60 | 1939 | 22 | 0.19 / 579.19 | 1 | 1 |
4 | 12 | 2005.16 | 45 | 10.44 | 3302 | 1551 | 1.75 / 580.74 | 1 | 1 |
5 | 7 | 2000.80 | 24 | 11.24 | 3417 | 922 | 2.67 / 581.67 | 1 | 1 |
6 | 13 | 1386.08 | 34 | 12.50 | 2509 | 1066 | 3.73 / 582.73 | 1 | 2 |
7 | 13 | 596.04 | 34 | 13.31 | 1294 | 586 | 4.32 / 583.32 | 1 | 2 |
8 | 13 | 14.72 | 34 | 14.12 | 354 | 170 | 4.49 / 583.49 | 1 | 2 |
9 | 8 | 0.12 | 160 | 14.00 | 318 | 712 | 5.20 / 584.20 | 1 | 5 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 25 | 14.22 | 469 | 167 | 0.17 / 573.97 | 2 | 2 |
2 | 3 | 967.56 | -1 | 15.19 | 0 | 0 | 0.00 / 573.97 | 2 | 2 |
3 | 3 | 1037.08 | 1 | 11.94 | 1940 | 23 | 0.19 / 574.00 | 1 | 1 |
4 | 12 | 2001.96 | 45 | 10.46 | 3282 | 1545 | 1.73 / 575.54 | 1 | 3 |
5 | 7 | 1997.68 | 24 | 11.27 | 3374 | 913 | 2.65 / 576.45 | 3 | 1 |
6 | 13 | 1689.12 | 34 | 12.22 | 2953 | 1227 | 3.87 / 577.68 | 1 | 1 |
7 | 13 | 652.12 | 34 | 13.30 | 1364 | 617 | 4.49 / 578.30 | 1 | 2 |
8 | 8 | -0.16 | 160 | 14.12 | 310 | 700 | 5.19 / 579.00 | 2 | 4 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.08 | 26 | 14.26 | 467 | 173 | 0.17 / 568.81 | 2 | 2 |
2 | 3 | 953.92 | -1 | 15.23 | 0 | 0 | 0.00 / 568.81 | 2 | 2 |
3 | 3 | 1023.76 | 1 | 10.93 | 1897 | 21 | 0.19 / 568.84 | 1 | 1 |
4 | 12 | 2003.72 | 45 | 10.31 | 3242 | 1504 | 1.70 / 570.34 | 1 | 1 |
5 | 7 | 1999.64 | 24 | 11.20 | 3377 | 908 | 2.61 / 571.25 | 1 | 1 |
6 | 13 | 1566.28 | 34 | 12.30 | 2769 | 1158 | 3.76 / 572.41 | 1 | 2 |
7 | 13 | 767.96 | 34 | 13.15 | 1556 | 696 | 4.46 / 573.10 | 1 | 2 |
8 | 8 | 0.20 | 160 | 14.12 | 312 | 705 | 5.16 / 573.81 | 2 | 3 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.92 | 24 | 14.22 | 478 | 163 | 0.16 / 563.69 | 2 | 2 |
2 | 3 | 1030.36 | 1 | 11.90 | 1919 | 23 | 0.19 / 563.71 | 1 | 1 |
3 | 3 | 1021.64 | 1 | 11.48 | 1904 | 22 | 0.21 / 563.73 | 1 | 1 |
4 | 12 | 2003.88 | 45 | 10.27 | 3245 | 1500 | 1.71 / 565.23 | 1 | 1 |
5 | 7 | 1999.36 | 24 | 11.18 | 3390 | 910 | 2.62 / 566.14 | 1 | 1 |
6 | 13 | 1579.12 | 34 | 12.31 | 2795 | 1170 | 3.79 / 567.31 | 1 | 1 |
7 | 13 | 697.48 | 34 | 13.30 | 1431 | 647 | 4.43 / 567.96 | 1 | 2 |
8 | 8 | 0.16 | 160 | 14.19 | 302 | 686 | 5.12 / 568.64 | 2 | 2 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 25 | 14.25 | 478 | 170 | 0.17 / 558.64 | 2 | 2 |
2 | 12 | 2001.04 | 45 | 10.24 | 3241 | 1493 | 1.66 / 560.13 | 1 | 1 |
3 | 7 | 1996.28 | 24 | 11.24 | 3352 | 904 | 2.57 / 561.03 | 1 | 1 |
4 | 13 | 1574.20 | 34 | 12.30 | 2790 | 1167 | 3.73 / 562.20 | 1 | 3 |
5 | 13 | 700.72 | 34 | 13.28 | 1442 | 651 | 4.39 / 562.85 | 1 | 2 |
6 | 8 | -0.32 | 160 | 14.17 | 296 | 671 | 5.06 / 563.52 | 2 | 2 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.56 | 25 | 14.20 | 478 | 170 | 0.17 / 553.29 | 2 | 2 |
2 | 3 | 966.08 | -1 | 15.23 | 0 | 0 | 0.00 / 553.29 | 2 | 2 |
3 | 3 | 1030.76 | 1 | 11.50 | 1908 | 22 | 0.19 / 553.31 | 1 | 1 |
4 | 12 | 1999.92 | 45 | 10.41 | 3250 | 1522 | 1.71 / 554.83 | 1 | 1 |
5 | 7 | 1995.32 | 24 | 11.22 | 3393 | 914 | 2.63 / 555.74 | 1 | 1 |
6 | 13 | 1567.12 | 34 | 12.32 | 2784 | 1166 | 3.79 / 556.91 | 1 | 2 |
7 | 13 | 775.72 | 34 | 13.18 | 1563 | 700 | 4.49 / 557.61 | 1 | 2 |
8 | 13 | 25.48 | 34 | 14.18 | 358 | 173 | 4.67 / 557.78 | 1 | 2 |
9 | 8 | 0.04 | 160 | 14.12 | 302 | 682 | 5.35 / 558.46 | 2 | 4 |
Average= | 4.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 25 | 14.21 | 487 | 173 | 0.17 / 547.79 | 2 | 2 |
2 | 3 | 962.48 | -1 | 15.22 | 0 | 0 | 0.00 / 547.79 | 2 | 2 |
3 | 3 | 1031.92 | 1 | 11.87 | 1921 | 23 | 0.20 / 547.81 | 1 | 1 |
4 | 12 | 2003.76 | 45 | 10.44 | 3274 | 1538 | 1.73 / 549.35 | 1 | 1 |
5 | 7 | 1999.24 | 24 | 11.24 | 3384 | 913 | 2.65 / 550.26 | 1 | 1 |
6 | 13 | 1580.64 | 34 | 12.31 | 2789 | 1167 | 3.81 / 551.43 | 1 | 2 |
7 | 13 | 995.92 | 34 | 12.92 | 1904 | 836 | 4.65 / 552.27 | 1 | 2 |
8 | 13 | 16.88 | 34 | 14.20 | 332 | 160 | 4.81 / 552.43 | 1 | 2 |
9 | 8 | 0.08 | 160 | 14.09 | 306 | 690 | 5.50 / 553.12 | 2 | 7 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 24 | 14.18 | 504 | 172 | 0.17 / 542.69 | 2 | 2 |
2 | 12 | 2004.28 | 45 | 10.55 | 3278 | 1556 | 1.73 / 544.25 | 1 | 2 |
3 | 7 | 1999.88 | 24 | 11.22 | 3396 | 914 | 2.64 / 545.16 | 2 | 1 |
4 | 13 | 1572.72 | 34 | 12.29 | 2790 | 1166 | 3.81 / 546.33 | 1 | 2 |
5 | 13 | 583.12 | 34 | 13.39 | 1260 | 574 | 4.38 / 546.90 | 1 | 2 |
6 | 8 | -0.32 | 160 | 14.09 | 316 | 712 | 5.09 / 547.62 | 2 | 2 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.32 | 25 | 14.18 | 486 | 172 | 0.17 / 537.59 | 1 | 2 |
2 | 12 | 2002.56 | 45 | 10.33 | 3269 | 1520 | 1.69 / 539.11 | 1 | 1 |
3 | 7 | 1998.16 | 24 | 11.19 | 3367 | 904 | 2.60 / 540.01 | 1 | 1 |
4 | 13 | 1576.76 | 34 | 12.28 | 2790 | 1165 | 3.76 / 541.17 | 1 | 2 |
5 | 13 | 669.80 | 34 | 13.28 | 1399 | 632 | 4.39 / 541.81 | 1 | 2 |
6 | 8 | 0.28 | 160 | 14.09 | 317 | 715 | 5.11 / 542.52 | 2 | 3 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.04 | 25 | 14.23 | 479 | 170 | 0.17 / 532.54 | 2 | 2 |
2 | 12 | 2004.88 | 45 | 10.36 | 3266 | 1523 | 1.69 / 534.06 | 1 | 2 |
3 | 7 | 2000.76 | 24 | 11.20 | 3367 | 905 | 2.60 / 534.96 | 2 | 1 |
4 | 13 | 1474.16 | 34 | 12.38 | 2643 | 1112 | 3.71 / 536.08 | 1 | 2 |
5 | 13 | 683.12 | 34 | 13.28 | 1417 | 640 | 4.35 / 536.72 | 1 | 2 |
6 | 8 | 0.28 | 160 | 14.11 | 309 | 698 | 5.05 / 537.41 | 1 | 3 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.12 | 25 | 14.18 | 474 | 168 | 0.17 / 527.19 | 1 | 2 |
2 | 3 | 973.32 | -1 | 15.23 | 0 | 0 | 0.00 / 527.19 | 1 | 2 |
3 | 3 | 1034.48 | 1 | 11.76 | 1914 | 23 | 0.19 / 527.22 | 1 | 1 |
4 | 12 | 2007.48 | 45 | 10.46 | 3294 | 1550 | 1.74 / 528.77 | 1 | 2 |
5 | 7 | 2003.48 | 24 | 11.23 | 3405 | 918 | 2.66 / 529.68 | 2 | 1 |
6 | 13 | 1585.08 | 34 | 12.30 | 2807 | 1174 | 3.83 / 530.86 | 1 | 2 |
7 | 13 | 689.96 | 34 | 13.29 | 1420 | 642 | 4.47 / 531.50 | 1 | 2 |
8 | 13 | 32.68 | 34 | 14.17 | 366 | 176 | 4.65 / 531.68 | 1 | 2 |
9 | 8 | -0.32 | 160 | 14.10 | 306 | 690 | 5.34 / 532.37 | 2 | 4 |
Average= | 4.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 25 | 14.22 | 489 | 174 | 0.17 / 522.15 | 1 | 2 |
2 | 12 | 2000.68 | 45 | 10.41 | 3288 | 1540 | 1.71 / 523.69 | 1 | 1 |
3 | 7 | 1995.84 | 24 | 11.23 | 3397 | 916 | 2.63 / 524.61 | 1 | 1 |
4 | 13 | 1470.12 | 34 | 12.41 | 2635 | 1112 | 3.74 / 525.72 | 1 | 1 |
5 | 13 | 601.44 | 34 | 13.38 | 1292 | 588 | 4.33 / 526.31 | 1 | 2 |
6 | 8 | -0.04 | 160 | 14.10 | 317 | 715 | 5.04 / 527.02 | 1 | 2 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.88 | 24 | 14.18 | 499 | 170 | 0.17 / 516.93 | 1 | 2 |
2 | 12 | 2000.00 | 45 | 10.60 | 3275 | 1562 | 1.73 / 518.49 | 1 | 2 |
3 | 7 | 1995.48 | 24 | 11.29 | 3387 | 918 | 2.65 / 519.41 | 2 | 1 |
4 | 13 | 1571.40 | 34 | 12.32 | 2786 | 1167 | 3.82 / 520.58 | 1 | 2 |
5 | 13 | 769.48 | 34 | 13.17 | 1553 | 695 | 4.51 / 521.27 | 1 | 2 |
6 | 8 | -0.08 | 160 | 14.10 | 313 | 706 | 5.22 / 521.98 | 1 | 3 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.32 | 24 | 14.22 | 480 | 164 | 0.16 / 511.71 | 1 | 2 |
2 | 12 | 2002.32 | 45 | 10.48 | 3289 | 1551 | 1.71 / 513.26 | 1 | 2 |
3 | 7 | 1997.68 | 24 | 11.25 | 3403 | 919 | 2.63 / 514.18 | 2 | 1 |
4 | 13 | 1568.12 | 34 | 12.31 | 2777 | 1162 | 3.80 / 515.34 | 1 | 2 |
5 | 13 | 765.16 | 34 | 13.16 | 1555 | 696 | 4.49 / 516.03 | 1 | 2 |
6 | 8 | 0.20 | 160 | 14.09 | 323 | 728 | 5.22 / 516.76 | 2 | 3 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.56 | 25 | 14.22 | 474 | 169 | 0.17 / 506.52 | 2 | 2 |
2 | 3 | 938.56 | -1 | 15.23 | 0 | 0 | 0.00 / 506.52 | 2 | 2 |
3 | 12 | 2000.92 | 45 | 10.61 | 3286 | 1569 | 1.74 / 508.09 | 1 | 1 |
4 | 7 | 1996.00 | 24 | 11.33 | 3388 | 921 | 2.66 / 509.01 | 1 | 1 |
5 | 13 | 1665.72 | 34 | 12.23 | 2921 | 1215 | 3.87 / 510.22 | 1 | 2 |
6 | 13 | 636.56 | 34 | 13.34 | 1344 | 610 | 4.48 / 510.83 | 1 | 2 |
7 | 8 | 0.12 | 160 | 14.10 | 315 | 711 | 5.19 / 511.54 | 2 | 4 |
Average= | 4.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.92 | 25 | 14.23 | 471 | 168 | 0.17 / 501.26 | 1 | 2 |
2 | 3 | 968.12 | -1 | 15.22 | 0 | 0 | 0.00 / 501.26 | 1 | 2 |
3 | 3 | 1033.08 | 1 | 11.78 | 1940 | 23 | 0.19 / 501.28 | 1 | 1 |
4 | 12 | 2006.44 | 45 | 10.67 | 3288 | 1579 | 1.77 / 502.86 | 1 | 1 |
5 | 7 | 2002.40 | 24 | 11.34 | 3408 | 928 | 2.70 / 503.79 | 1 | 1 |
6 | 13 | 1688.72 | 34 | 12.22 | 2958 | 1229 | 3.93 / 505.01 | 1 | 1 |
7 | 13 | 659.28 | 34 | 13.29 | 1377 | 622 | 4.55 / 505.64 | 1 | 2 |
8 | 8 | 0.24 | 160 | 14.09 | 316 | 712 | 5.26 / 506.35 | 2 | 3 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.52 | 25 | 14.23 | 491 | 175 | 0.17 / 495.97 | 2 | 2 |
2 | 3 | 970.08 | -1 | 15.23 | 0 | 0 | 0.00 / 495.97 | 2 | 2 |
3 | 3 | 1039.96 | 1 | 12.12 | 1914 | 23 | 0.20 / 496.00 | 1 | 1 |
4 | 12 | 2003.28 | 45 | 10.48 | 3289 | 1551 | 1.75 / 497.55 | 1 | 1 |
5 | 7 | 1998.92 | 24 | 11.30 | 3396 | 921 | 2.67 / 498.47 | 1 | 1 |
6 | 13 | 1686.20 | 34 | 12.20 | 2951 | 1224 | 3.89 / 499.69 | 1 | 2 |
7 | 13 | 774.92 | 34 | 13.15 | 1571 | 702 | 4.60 / 500.40 | 1 | 2 |
8 | 8 | -0.04 | 160 | 14.11 | 307 | 693 | 5.29 / 501.09 | 2 | 2 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.24 | 25 | 14.27 | 493 | 176 | 0.18 / 490.77 | 2 | 2 |
2 | 12 | 2000.48 | 45 | 10.44 | 3260 | 1532 | 1.71 / 492.30 | 1 | 2 |
3 | 7 | 1996.04 | 24 | 11.25 | 3400 | 918 | 2.63 / 493.22 | 2 | 1 |
4 | 13 | 1574.64 | 34 | 12.31 | 2792 | 1169 | 3.79 / 494.38 | 1 | 2 |
5 | 13 | 775.72 | 34 | 13.19 | 1564 | 701 | 4.50 / 495.09 | 1 | 2 |
6 | 8 | 0.16 | 160 | 14.11 | 316 | 713 | 5.21 / 495.80 | 1 | 2 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 24 | 14.26 | 470 | 161 | 0.16 / 485.63 | 2 | 2 |
2 | 12 | 2002.68 | 45 | 10.46 | 3259 | 1534 | 1.69 / 487.16 | 1 | 2 |
3 | 7 | 1998.52 | 24 | 11.31 | 3404 | 924 | 2.62 / 488.09 | 2 | 1 |
4 | 13 | 1495.92 | 34 | 12.40 | 2683 | 1131 | 3.75 / 489.22 | 1 | 3 |
5 | 13 | 708.36 | 34 | 13.28 | 1461 | 660 | 4.41 / 489.88 | 1 | 2 |
6 | 8 | 0.28 | 160 | 14.12 | 316 | 714 | 5.12 / 490.59 | 2 | 4 |
Average= | 4.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.52 | 24 | 14.28 | 478 | 164 | 0.16 / 480.51 | 2 | 2 |
2 | 12 | 2000.52 | 45 | 10.45 | 3262 | 1534 | 1.70 / 482.05 | 1 | 1 |
3 | 7 | 1995.44 | 24 | 11.31 | 3393 | 921 | 2.62 / 482.97 | 1 | 1 |
4 | 13 | 1452.28 | 34 | 12.44 | 2607 | 1103 | 3.72 / 484.07 | 1 | 1 |
5 | 13 | 766.48 | 34 | 13.21 | 1547 | 695 | 4.42 / 484.76 | 1 | 2 |
6 | 8 | 0.08 | 160 | 14.12 | 311 | 703 | 5.12 / 485.47 | 1 | 5 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.96 | 24 | 14.24 | 493 | 168 | 0.17 / 475.47 | 2 | 2 |
2 | 12 | 2003.16 | 45 | 10.53 | 3310 | 1568 | 1.74 / 477.03 | 1 | 1 |
3 | 7 | 1998.64 | 24 | 11.33 | 3398 | 924 | 2.66 / 477.96 | 1 | 1 |
4 | 13 | 1476.76 | 34 | 12.42 | 2650 | 1119 | 3.78 / 479.08 | 1 | 2 |
5 | 13 | 577.00 | 34 | 13.44 | 1248 | 570 | 4.35 / 479.65 | 1 | 2 |
6 | 8 | 0.00 | 160 | 14.12 | 310 | 700 | 5.05 / 480.35 | 2 | 2 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 24 | 14.27 | 459 | 157 | 0.16 / 470.22 | 2 | 2 |
2 | 12 | 2001.40 | 45 | 10.55 | 3288 | 1561 | 1.72 / 471.78 | 1 | 2 |
3 | 7 | 1997.00 | 24 | 11.35 | 3405 | 928 | 2.65 / 472.71 | 2 | 1 |
4 | 13 | 1575.76 | 34 | 12.33 | 2795 | 1172 | 3.82 / 473.88 | 1 | 2 |
5 | 13 | 771.04 | 34 | 13.17 | 1568 | 702 | 4.52 / 474.58 | 1 | 2 |
6 | 8 | -0.04 | 160 | 14.11 | 316 | 713 | 5.23 / 475.30 | 2 | 4 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.64 | 24 | 14.27 | 471 | 161 | 0.16 / 465.03 | 2 | 2 |
2 | 12 | 1999.52 | 45 | 10.53 | 3307 | 1567 | 1.73 / 466.60 | 1 | 2 |
3 | 7 | 1994.84 | 24 | 11.31 | 3418 | 928 | 2.66 / 467.53 | 2 | 2 |
4 | 13 | 1568.32 | 34 | 12.32 | 2791 | 1169 | 3.83 / 468.70 | 1 | 1 |
5 | 13 | 747.60 | 34 | 13.20 | 1529 | 686 | 4.51 / 469.38 | 1 | 2 |
6 | 8 | 0.04 | 160 | 14.13 | 302 | 683 | 5.19 / 470.06 | 1 | 3 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 24 | 14.29 | 465 | 159 | 0.16 / 459.95 | 2 | 2 |
2 | 12 | 2001.80 | 45 | 10.56 | 3282 | 1560 | 1.72 / 461.51 | 1 | 2 |
3 | 7 | 1997.04 | 24 | 11.34 | 3362 | 915 | 2.63 / 462.42 | 2 | 1 |
4 | 13 | 1471.16 | 34 | 12.42 | 2629 | 1110 | 3.74 / 463.53 | 1 | 2 |
5 | 13 | 675.60 | 34 | 13.29 | 1415 | 639 | 4.38 / 464.17 | 1 | 2 |
6 | 8 | 0.20 | 160 | 14.10 | 310 | 699 | 5.08 / 464.87 | 1 | 4 |
Average= | 4.95 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.84 | 24 | 14.28 | 469 | 161 | 0.16 / 454.80 | 2 | 2 |
2 | 12 | 2000.52 | 45 | 10.65 | 3268 | 1566 | 1.73 / 456.36 | 1 | 2 |
3 | 7 | 1995.80 | 24 | 11.35 | 3399 | 926 | 2.65 / 457.29 | 2 | 1 |
4 | 13 | 1564.28 | 34 | 12.35 | 2771 | 1164 | 3.82 / 458.45 | 1 | 1 |
5 | 13 | 657.16 | 34 | 13.32 | 1377 | 624 | 4.44 / 459.08 | 1 | 2 |
6 | 8 | -0.20 | 160 | 14.10 | 315 | 711 | 5.15 / 459.79 | 2 | 3 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 24 | 14.28 | 476 | 163 | 0.16 / 449.59 | 2 | 2 |
2 | 12 | 2001.56 | 45 | 10.59 | 3292 | 1569 | 1.73 / 451.16 | 1 | 1 |
3 | 7 | 1996.88 | 25 | 11.39 | 3411 | 971 | 2.70 / 452.13 | 1 | 1 |
4 | 13 | 1555.20 | 34 | 12.36 | 2767 | 1163 | 3.87 / 453.30 | 1 | 2 |
5 | 13 | 644.56 | 34 | 13.34 | 1360 | 617 | 4.48 / 453.91 | 1 | 2 |
6 | 8 | 0.28 | 160 | 14.10 | 320 | 722 | 5.20 / 454.64 | 2 | 4 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.68 | 24 | 14.30 | 465 | 160 | 0.16 / 444.48 | 2 | 2 |
2 | 12 | 2000.48 | 45 | 10.56 | 3278 | 1558 | 1.72 / 446.03 | 1 | 1 |
3 | 7 | 1995.92 | 24 | 11.37 | 3408 | 930 | 2.65 / 446.96 | 1 | 1 |
4 | 13 | 1550.32 | 34 | 12.36 | 2759 | 1159 | 3.81 / 448.12 | 1 | 3 |
5 | 13 | 635.12 | 34 | 13.37 | 1340 | 609 | 4.42 / 448.73 | 1 | 2 |
6 | 8 | 0.04 | 160 | 14.12 | 310 | 700 | 5.12 / 449.43 | 2 | 3 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 24 | 14.31 | 462 | 159 | 0.16 / 439.44 | 2 | 2 |
2 | 12 | 2003.12 | 45 | 10.65 | 3289 | 1576 | 1.73 / 441.01 | 1 | 1 |
3 | 7 | 1998.52 | 24 | 11.39 | 3395 | 928 | 2.66 / 441.94 | 1 | 2 |
4 | 13 | 1459.96 | 34 | 12.47 | 2628 | 1114 | 3.78 / 443.05 | 1 | 2 |
5 | 13 | 567.44 | 34 | 13.47 | 1229 | 563 | 4.34 / 443.62 | 1 | 2 |
6 | 8 | 0.32 | 160 | 14.12 | 309 | 698 | 5.04 / 444.32 | 2 | 3 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 24 | 14.28 | 474 | 162 | 0.16 / 434.14 | 2 | 2 |
2 | 3 | 964.56 | -1 | 15.24 | 0 | 0 | 0.00 / 434.14 | 2 | 2 |
3 | 3 | 1034.68 | 1 | 12.15 | 1941 | 24 | 0.19 / 434.16 | 1 | 1 |
4 | 12 | 1999.24 | 45 | 10.80 | 3288 | 1598 | 1.78 / 435.76 | 1 | 2 |
5 | 7 | 1994.28 | 47 | 10.95 | 3379 | 1739 | 3.52 / 437.50 | 2 | 2 |
6 | 13 | 1054.48 | 34 | 12.86 | 2007 | 878 | 4.40 / 438.38 | 1 | 2 |
7 | 13 | 52.56 | 34 | 14.16 | 405 | 195 | 4.60 / 438.57 | 1 | 2 |
8 | 8 | 0.04 | 160 | 14.11 | 312 | 704 | 5.30 / 439.28 | 2 | 3 |
Average= | 4.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.24 | 24 | 14.30 | 490 | 168 | 0.17 / 428.83 | 2 | 2 |
2 | 12 | 2000.92 | 45 | 10.69 | 3270 | 1573 | 1.74 / 430.41 | 1 | 1 |
3 | 7 | 1996.04 | 48 | 10.94 | 3370 | 1770 | 3.51 / 432.18 | 1 | 2 |
4 | 13 | 1063.68 | 34 | 12.85 | 2021 | 883 | 4.39 / 433.06 | 1 | 2 |
5 | 13 | 59.52 | 34 | 14.14 | 423 | 203 | 4.60 / 433.26 | 1 | 2 |
6 | 8 | 0.16 | 160 | 14.10 | 317 | 715 | 5.31 / 433.98 | 1 | 3 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.36 | 24 | 14.27 | 475 | 163 | 0.16 / 423.79 | 2 | 2 |
2 | 12 | 1828.64 | 45 | 10.79 | 3042 | 1477 | 1.64 / 425.27 | 1 | 1 |
3 | 7 | 1824.36 | 47 | 10.99 | 3132 | 1618 | 3.26 / 426.88 | 1 | 1 |
4 | 13 | 1020.76 | 34 | 12.88 | 1955 | 856 | 4.11 / 427.74 | 1 | 2 |
5 | 13 | 51.40 | 34 | 14.16 | 411 | 198 | 4.31 / 427.94 | 1 | 2 |
6 | 8 | -0.16 | 160 | 14.07 | 323 | 727 | 5.04 / 428.67 | 1 | 4 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 24 | 14.32 | 457 | 157 | 0.16 / 418.64 | 2 | 2 |
2 | 12 | 1796.08 | 45 | 10.84 | 3032 | 1479 | 1.64 / 420.12 | 1 | 1 |
3 | 7 | 1791.72 | 24 | 11.60 | 3104 | 864 | 2.50 / 420.98 | 1 | 1 |
4 | 13 | 1470.28 | 33 | 12.46 | 2643 | 1087 | 3.59 / 422.07 | 1 | 1 |
5 | 13 | 749.72 | 33 | 13.22 | 1536 | 670 | 4.26 / 422.74 | 1 | 2 |
6 | 13 | 35.32 | 33 | 14.16 | 381 | 178 | 4.44 / 422.92 | 1 | 2 |
7 | 8 | 0.08 | 160 | 14.06 | 316 | 711 | 5.15 / 423.63 | 1 | 4 |
Average= | 4.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 24 | 14.30 | 459 | 158 | 0.16 / 413.55 | 2 | 2 |
2 | 12 | 2001.64 | 45 | 10.69 | 3273 | 1574 | 1.73 / 415.13 | 1 | 2 |
3 | 7 | 1997.04 | 24 | 11.46 | 3414 | 939 | 2.67 / 416.07 | 2 | 1 |
4 | 13 | 1480.84 | 33 | 12.49 | 2654 | 1094 | 3.76 / 417.16 | 1 | 2 |
5 | 13 | 682.56 | 33 | 13.33 | 1418 | 624 | 4.39 / 417.78 | 1 | 2 |
6 | 8 | -0.20 | 160 | 14.12 | 308 | 696 | 5.08 / 418.48 | 2 | 4 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.44 | 25 | 14.31 | 464 | 166 | 0.17 / 408.20 | 2 | 2 |
2 | 3 | 951.56 | -1 | 15.25 | 0 | 0 | 0.00 / 408.20 | 2 | 2 |
3 | 12 | 2001.20 | 45 | 10.68 | 3307 | 1589 | 1.76 / 409.79 | 1 | 1 |
4 | 7 | 1996.20 | 24 | 11.53 | 3414 | 945 | 2.70 / 410.73 | 1 | 1 |
5 | 13 | 1663.68 | 33 | 12.35 | 2922 | 1191 | 3.89 / 411.92 | 1 | 1 |
6 | 13 | 628.84 | 33 | 13.40 | 1338 | 592 | 4.48 / 412.51 | 1 | 2 |
7 | 13 | 26.12 | 33 | 14.20 | 366 | 172 | 4.65 / 412.68 | 1 | 2 |
8 | 8 | 0.04 | 160 | 14.07 | 316 | 711 | 5.37 / 413.40 | 1 | 2 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 24 | 14.33 | 475 | 163 | 0.16 / 402.78 | 2 | 2 |
2 | 3 | 1022.56 | 1 | 10.86 | 1944 | 21 | 0.18 / 402.80 | 1 | 1 |
3 | 3 | 1020.76 | 1 | 11.48 | 1917 | 22 | 0.21 / 402.83 | 1 | 1 |
4 | 12 | 2000.88 | 45 | 10.76 | 3289 | 1593 | 1.80 / 404.42 | 1 | 2 |
5 | 7 | 1995.96 | 24 | 11.50 | 3407 | 940 | 2.74 / 405.36 | 2 | 1 |
6 | 13 | 1558.68 | 33 | 12.44 | 2776 | 1140 | 3.88 / 406.50 | 1 | 2 |
7 | 13 | 744.64 | 33 | 13.26 | 1519 | 665 | 4.54 / 407.16 | 1 | 2 |
8 | 13 | 17.92 | 33 | 14.21 | 351 | 165 | 4.71 / 407.33 | 1 | 2 |
9 | 8 | -0.04 | 160 | 14.04 | 313 | 703 | 5.41 / 408.03 | 1 | 3 |
Average= | 4.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 25 | 14.31 | 457 | 163 | 0.16 / 397.53 | 1 | 2 |
2 | 3 | 938.80 | -1 | 15.26 | 0 | 0 | 0.00 / 397.53 | 1 | 2 |
3 | 12 | 2004.96 | 45 | 10.67 | 3311 | 1590 | 1.75 / 399.12 | 1 | 2 |
4 | 7 | 2000.52 | 24 | 11.45 | 3430 | 943 | 2.70 / 400.06 | 2 | 1 |
5 | 13 | 1560.64 | 31 | 12.48 | 2776 | 1074 | 3.77 / 401.14 | 1 | 1 |
6 | 13 | 763.24 | 31 | 13.27 | 1549 | 637 | 4.41 / 401.77 | 1 | 2 |
7 | 13 | 26.44 | 31 | 14.22 | 357 | 157 | 4.56 / 401.93 | 1 | 2 |
8 | 8 | -0.24 | 160 | 14.09 | 305 | 688 | 5.25 / 402.62 | 2 | 3 |
Average= | 4.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 24 | 14.29 | 477 | 164 | 0.16 / 392.36 | 2 | 2 |
2 | 3 | 1031.40 | 1 | 12.51 | 1939 | 24 | 0.19 / 392.38 | 1 | 1 |
3 | 12 | 1999.28 | 45 | 10.76 | 3289 | 1593 | 1.78 / 393.97 | 1 | 1 |
4 | 7 | 1994.52 | 24 | 11.48 | 3393 | 935 | 2.72 / 394.91 | 1 | 1 |
5 | 13 | 1461.44 | 31 | 12.58 | 2622 | 1023 | 3.74 / 395.93 | 1 | 2 |
6 | 13 | 681.64 | 31 | 13.37 | 1419 | 588 | 4.33 / 396.52 | 1 | 2 |
7 | 13 | 14.68 | 31 | 14.22 | 343 | 151 | 4.48 / 396.67 | 1 | 2 |
8 | 8 | 0.16 | 160 | 14.05 | 310 | 697 | 5.17 / 397.37 | 1 | 3 |
Average= | 4.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.68 | 24 | 14.32 | 486 | 167 | 0.17 / 387.41 | 2 | 2 |
2 | 12 | 2000.76 | 45 | 10.61 | 3273 | 1563 | 1.73 / 388.97 | 1 | 3 |
3 | 7 | 1995.76 | 24 | 11.45 | 3402 | 935 | 2.66 / 389.90 | 3 | 1 |
4 | 13 | 1361.20 | 31 | 12.66 | 2479 | 973 | 3.64 / 390.88 | 1 | 1 |
5 | 13 | 701.48 | 31 | 13.34 | 1460 | 604 | 4.24 / 391.48 | 1 | 2 |
6 | 8 | -0.08 | 160 | 14.11 | 316 | 713 | 4.95 / 392.19 | 1 | 3 |
Average= | 4.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.12 | 24 | 14.29 | 481 | 165 | 0.16 / 382.27 | 1 | 2 |
2 | 12 | 2002.08 | 45 | 10.58 | 3278 | 1561 | 1.73 / 383.83 | 1 | 2 |
3 | 7 | 1997.60 | 24 | 11.46 | 3418 | 940 | 2.67 / 384.77 | 2 | 1 |
4 | 13 | 1453.32 | 31 | 12.60 | 2618 | 1023 | 3.69 / 385.80 | 1 | 2 |
5 | 13 | 674.32 | 31 | 13.39 | 1408 | 584 | 4.27 / 386.38 | 1 | 2 |
6 | 13 | 16.92 | 31 | 14.22 | 349 | 154 | 4.43 / 386.53 | 1 | 2 |
7 | 8 | 0.08 | 160 | 14.05 | 313 | 704 | 5.13 / 387.24 | 2 | 4 |
Average= | 4.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.92 | 24 | 14.31 | 483 | 166 | 0.17 / 377.05 | 1 | 2 |
2 | 12 | 2004.24 | 45 | 10.62 | 3299 | 1577 | 1.74 / 378.63 | 1 | 2 |
3 | 7 | 1999.88 | 24 | 11.46 | 3414 | 939 | 2.68 / 379.57 | 2 | 2 |
4 | 13 | 1469.16 | 31 | 12.59 | 2626 | 1025 | 3.71 / 380.59 | 1 | 2 |
5 | 13 | 785.00 | 31 | 13.26 | 1587 | 652 | 4.36 / 381.24 | 1 | 2 |
6 | 13 | 28.64 | 31 | 14.21 | 370 | 163 | 4.52 / 381.41 | 1 | 2 |
7 | 8 | 0.00 | 160 | 14.07 | 312 | 702 | 5.22 / 382.11 | 1 | 3 |
Average= | 4.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.32 | 25 | 14.31 | 478 | 171 | 0.17 / 371.98 | 1 | 2 |
2 | 3 | 956.04 | -1 | 15.26 | 0 | 0 | 0.00 / 371.98 | 1 | 2 |
3 | 3 | 1023.88 | 1 | 11.74 | 1925 | 23 | 0.19 / 372.01 | 1 | 1 |
4 | 12 | 2000.28 | 45 | 10.76 | 3303 | 1599 | 1.79 / 373.60 | 1 | 1 |
5 | 7 | 1995.52 | 25 | 11.48 | 3391 | 973 | 2.77 / 374.58 | 1 | 2 |
6 | 13 | 1457.00 | 31 | 12.61 | 2605 | 1018 | 3.78 / 375.60 | 1 | 2 |
7 | 13 | 668.92 | 31 | 13.41 | 1399 | 582 | 4.37 / 376.18 | 1 | 2 |
8 | 8 | 0.04 | 160 | 14.10 | 313 | 706 | 5.07 / 376.88 | 1 | 5 |
Average= | 4.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.84 | 25 | 14.33 | 496 | 178 | 0.18 / 366.98 | 2 | 2 |
2 | 3 | 972.72 | -1 | 15.26 | 0 | 0 | 0.00 / 366.98 | 2 | 2 |
3 | 3 | 1039.04 | 1 | 12.69 | 1934 | 25 | 0.20 / 367.00 | 1 | 1 |
4 | 7 | 2001.76 | 57 | 10.64 | 3366 | 2041 | 2.24 / 369.05 | 1 | 1 |
5 | 13 | 1691.76 | 33 | 12.35 | 2962 | 1207 | 3.45 / 370.25 | 1 | 2 |
6 | 13 | 1017.44 | 33 | 13.01 | 1959 | 841 | 4.29 / 371.09 | 1 | 2 |
7 | 8 | 0.24 | 160 | 14.12 | 318 | 718 | 5.01 / 371.81 | 1 | 6 |
Average= | 4.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 24 | 14.32 | 505 | 174 | 0.17 / 361.86 | 2 | 2 |
2 | 3 | 1032.12 | 1 | 12.67 | 1929 | 24 | 0.20 / 361.89 | 1 | 1 |
3 | 7 | 2004.56 | 58 | 10.56 | 3377 | 2068 | 2.27 / 363.96 | 1 | 2 |
4 | 13 | 1904.04 | 33 | 12.09 | 3268 | 1304 | 3.57 / 365.26 | 1 | 2 |
5 | 13 | 1002.88 | 33 | 13.03 | 1922 | 826 | 4.40 / 366.09 | 1 | 2 |
6 | 8 | 0.28 | 160 | 14.12 | 317 | 716 | 5.11 / 366.80 | 2 | 3 |
Average= | 4.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.36 | 24 | 14.34 | 487 | 168 | 0.17 / 356.78 | 1 | 2 |
2 | 7 | 2012.60 | 58 | 10.60 | 3370 | 2072 | 2.24 / 358.85 | 2 | 1 |
3 | 13 | 1913.72 | 33 | 12.09 | 3281 | 1309 | 3.55 / 360.16 | 1 | 1 |
4 | 13 | 998.28 | 33 | 13.06 | 1906 | 821 | 4.37 / 360.98 | 1 | 2 |
5 | 8 | 0.40 | 160 | 14.15 | 314 | 711 | 5.08 / 361.69 | 2 | 2 |
Average= | 4.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.60 | 23 | 14.34 | 465 | 153 | 0.15 / 351.49 | 2 | 2 |
2 | 7 | 2007.48 | 58 | 10.71 | 3386 | 2103 | 2.26 / 353.60 | 1 | 2 |
3 | 13 | 1908.84 | 33 | 12.11 | 3282 | 1312 | 3.57 / 354.91 | 1 | 2 |
4 | 13 | 991.44 | 33 | 13.06 | 1901 | 819 | 4.39 / 355.73 | 1 | 2 |
5 | 13 | 32.28 | 33 | 14.23 | 370 | 174 | 4.56 / 355.90 | 1 | 2 |
6 | 8 | -0.04 | 160 | 14.09 | 314 | 708 | 5.27 / 356.61 | 2 | 4 |
Average= | 4.89 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.12 | 24 | 14.34 | 480 | 165 | 0.17 / 346.54 | 2 | 2 |
2 | 7 | 2006.28 | 57 | 10.69 | 3386 | 2063 | 2.23 / 348.61 | 2 | 2 |
3 | 13 | 1705.76 | 33 | 12.40 | 2980 | 1219 | 3.45 / 349.82 | 1 | 2 |
4 | 13 | 955.40 | 33 | 13.11 | 1854 | 802 | 4.25 / 350.63 | 1 | 3 |
5 | 8 | 0.12 | 160 | 14.13 | 315 | 712 | 4.96 / 351.34 | 2 | 4 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 24 | 14.35 | 481 | 166 | 0.17 / 341.40 | 2 | 2 |
2 | 7 | 2003.72 | 57 | 10.79 | 3386 | 2082 | 2.25 / 343.48 | 2 | 2 |
3 | 13 | 1796.36 | 33 | 12.31 | 3116 | 1266 | 3.51 / 344.75 | 1 | 1 |
4 | 13 | 899.12 | 33 | 13.18 | 1756 | 764 | 4.28 / 345.51 | 1 | 2 |
5 | 13 | 15.80 | 33 | 14.26 | 342 | 161 | 4.44 / 345.67 | 1 | 2 |
6 | 8 | 0.00 | 160 | 14.06 | 313 | 704 | 5.14 / 346.38 | 2 | 8 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.08 | 24 | 14.35 | 483 | 166 | 0.17 / 336.28 | 1 | 2 |
2 | 7 | 2003.08 | 57 | 10.84 | 3400 | 2101 | 2.27 / 338.38 | 1 | 1 |
3 | 13 | 1681.16 | 33 | 12.46 | 2946 | 1211 | 3.48 / 339.59 | 1 | 3 |
4 | 13 | 892.28 | 33 | 13.21 | 1744 | 760 | 4.24 / 340.35 | 1 | 2 |
5 | 13 | 31.68 | 33 | 14.25 | 373 | 175 | 4.41 / 340.53 | 1 | 2 |
6 | 8 | -0.04 | 160 | 14.10 | 313 | 706 | 5.12 / 341.23 | 2 | 3 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 24 | 14.34 | 476 | 164 | 0.16 / 331.23 | 2 | 2 |
2 | 7 | 2002.56 | 57 | 10.89 | 3388 | 2103 | 2.27 / 333.33 | 2 | 3 |
3 | 13 | 1697.48 | 33 | 12.45 | 2967 | 1219 | 3.49 / 334.55 | 1 | 2 |
4 | 13 | 1007.28 | 33 | 13.11 | 1940 | 839 | 4.33 / 335.39 | 1 | 2 |
5 | 8 | 0.04 | 160 | 14.12 | 319 | 721 | 5.05 / 336.11 | 2 | 4 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.80 | 24 | 14.35 | 487 | 168 | 0.17 / 326.12 | 1 | 2 |
2 | 7 | 2004.48 | 58 | 11.01 | 3388 | 2164 | 2.33 / 328.28 | 2 | 2 |
3 | 13 | 1698.32 | 33 | 12.46 | 2982 | 1226 | 3.56 / 329.51 | 1 | 2 |
4 | 13 | 1025.48 | 33 | 13.10 | 1956 | 846 | 4.40 / 330.35 | 1 | 2 |
5 | 8 | 0.04 | 160 | 14.12 | 316 | 714 | 5.12 / 331.07 | 1 | 4 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.40 | 24 | 14.37 | 487 | 168 | 0.17 / 320.85 | 1 | 2 |
2 | 7 | 2006.12 | 57 | 11.16 | 3389 | 2156 | 2.32 / 323.01 | 1 | 1 |
3 | 13 | 1795.32 | 33 | 12.42 | 3118 | 1278 | 3.60 / 324.28 | 1 | 1 |
4 | 13 | 1196.44 | 33 | 12.97 | 2222 | 951 | 4.55 / 325.23 | 1 | 2 |
5 | 8 | 0.36 | 160 | 14.12 | 317 | 716 | 5.27 / 325.95 | 2 | 3 |
Average= | 4.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 24 | 14.37 | 496 | 171 | 0.17 / 315.90 | 1 | 2 |
2 | 7 | 2009.56 | 58 | 11.25 | 3408 | 2224 | 2.39 / 318.12 | 2 | 2 |
3 | 13 | 1599.36 | 33 | 12.62 | 2839 | 1182 | 3.58 / 319.31 | 1 | 1 |
4 | 13 | 716.44 | 33 | 13.46 | 1471 | 653 | 4.23 / 319.96 | 1 | 2 |
5 | 8 | -0.24 | 160 | 14.12 | 320 | 723 | 4.95 / 320.68 | 1 | 3 |
Average= | 4.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.00 | 23 | 14.37 | 504 | 167 | 0.17 / 310.86 | 1 | 2 |
2 | 3 | 1037.84 | 1 | 13.19 | 1943 | 26 | 0.19 / 310.89 | 1 | 1 |
3 | 7 | 2002.04 | 58 | 11.37 | 3401 | 2243 | 2.44 / 313.13 | 1 | 1 |
4 | 13 | 1582.64 | 33 | 12.66 | 2805 | 1172 | 3.61 / 314.30 | 1 | 2 |
5 | 13 | 791.88 | 33 | 13.39 | 1596 | 705 | 4.31 / 315.01 | 1 | 2 |
6 | 8 | 0.20 | 160 | 14.13 | 319 | 721 | 5.03 / 315.73 | 1 | 3 |
Average= | 4.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 23 | 14.36 | 473 | 156 | 0.16 / 305.56 | 1 | 2 |
2 | 3 | 1026.88 | 1 | 13.13 | 1938 | 25 | 0.18 / 305.58 | 1 | 1 |
3 | 7 | 1956.64 | 57 | 11.46 | 3337 | 2180 | 2.36 / 307.76 | 1 | 1 |
4 | 13 | 1755.44 | 33 | 12.53 | 3058 | 1264 | 3.63 / 309.02 | 1 | 2 |
5 | 13 | 1174.96 | 33 | 13.04 | 2200 | 947 | 4.57 / 309.97 | 1 | 2 |
6 | 8 | 0.20 | 160 | 14.14 | 320 | 724 | 5.30 / 310.70 | 1 | 4 |
Average= | 4.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.76 | 23 | 14.35 | 497 | 164 | 0.16 / 301.03 | 1 | 2 |
2 | 7 | 1685.52 | 57 | 11.71 | 2939 | 1962 | 2.13 / 302.99 | 2 | 1 |
3 | 13 | 1480.04 | 33 | 12.71 | 2662 | 1117 | 3.24 / 304.10 | 1 | 2 |
4 | 13 | 569.92 | 33 | 13.62 | 1248 | 561 | 3.80 / 304.67 | 1 | 2 |
5 | 8 | 0.20 | 160 | 14.11 | 325 | 734 | 4.54 / 305.40 | 1 | 4 |
Average= | 4.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.48 | 23 | 14.37 | 479 | 158 | 0.16 / 296.93 | 1 | 2 |
2 | 7 | 1396.64 | 58 | 12.08 | 2508 | 1757 | 1.92 / 298.68 | 1 | 2 |
3 | 13 | 1305.48 | 33 | 12.78 | 2389 | 1008 | 2.92 / 299.69 | 1 | 2 |
4 | 13 | 398.80 | 33 | 13.82 | 969 | 442 | 3.36 / 300.13 | 1 | 2 |
5 | 8 | 0.16 | 160 | 14.12 | 323 | 730 | 4.09 / 300.86 | 1 | 3 |
Average= | 4.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.76 | 23 | 14.39 | 484 | 160 | 0.16 / 292.28 | 1 | 2 |
2 | 7 | 1736.96 | 58 | 11.85 | 3021 | 2076 | 2.24 / 294.36 | 2 | 1 |
3 | 13 | 1532.96 | 33 | 12.74 | 2748 | 1155 | 3.39 / 295.52 | 1 | 6 |
4 | 13 | 519.36 | 33 | 13.70 | 1167 | 528 | 3.92 / 296.04 | 1 | 2 |
5 | 8 | 0.12 | 160 | 14.13 | 320 | 723 | 4.64 / 296.77 | 1 | 4 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.96 | 24 | 14.36 | 470 | 162 | 0.16 / 286.99 | 2 | 2 |
2 | 3 | 952.48 | -1 | 15.25 | 0 | 0 | 0.00 / 286.99 | 2 | 2 |
3 | 7 | 2003.16 | 57 | 11.77 | 3402 | 2282 | 2.44 / 289.28 | 1 | 1 |
4 | 13 | 1693.48 | 33 | 12.70 | 2983 | 1250 | 3.69 / 290.53 | 1 | 3 |
5 | 13 | 786.88 | 33 | 13.44 | 1594 | 707 | 4.40 / 291.23 | 1 | 2 |
6 | 13 | 14.28 | 33 | 14.28 | 351 | 165 | 4.57 / 291.40 | 1 | 2 |
7 | 8 | 0.36 | 160 | 14.07 | 322 | 725 | 5.29 / 292.12 | 2 | 4 |
Average= | 4.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 23 | 14.41 | 485 | 161 | 0.16 / 281.95 | 2 | 2 |
2 | 3 | 1021.24 | 1 | 12.70 | 1956 | 25 | 0.19 / 281.98 | 1 | 1 |
3 | 3 | 1019.52 | 1 | 12.97 | 1955 | 25 | 0.21 / 282.00 | 1 | 1 |
4 | 7 | 2001.40 | 57 | 11.86 | 3402 | 2300 | 2.51 / 284.30 | 1 | 1 |
5 | 13 | 1450.60 | 33 | 12.89 | 2621 | 1115 | 3.63 / 285.42 | 1 | 2 |
6 | 13 | 774.92 | 33 | 13.47 | 1572 | 699 | 4.32 / 286.11 | 1 | 2 |
7 | 8 | 0.04 | 160 | 14.16 | 317 | 718 | 5.04 / 286.83 | 2 | 3 |
Average= | 4.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.68 | 23 | 14.40 | 472 | 156 | 0.16 / 276.92 | 1 | 2 |
2 | 3 | 972.92 | -1 | 15.24 | 0 | 0 | 0.00 / 276.92 | 1 | 2 |
3 | 3 | 1040.84 | 1 | 13.44 | 1954 | 26 | 0.18 / 276.95 | 1 | 1 |
4 | 7 | 2004.40 | 57 | 11.94 | 3403 | 2316 | 2.50 / 279.26 | 1 | 1 |
5 | 13 | 1484.84 | 32 | 12.93 | 2676 | 1107 | 3.61 / 280.37 | 1 | 2 |
6 | 13 | 789.64 | 32 | 13.49 | 1602 | 692 | 4.30 / 281.06 | 1 | 2 |
7 | 8 | 0.12 | 160 | 14.15 | 322 | 729 | 5.03 / 281.79 | 1 | 5 |
Average= | 4.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 23 | 14.42 | 480 | 159 | 0.16 / 271.63 | 1 | 2 |
2 | 7 | 2008.48 | 57 | 12.03 | 3421 | 2346 | 2.51 / 273.98 | 2 | 2 |
3 | 13 | 1487.68 | 32 | 12.95 | 2672 | 1107 | 3.61 / 275.08 | 1 | 3 |
4 | 13 | 900.68 | 32 | 13.39 | 1784 | 764 | 4.38 / 275.85 | 1 | 2 |
5 | 13 | 39.32 | 32 | 14.25 | 395 | 180 | 4.56 / 276.03 | 1 | 2 |
6 | 8 | 0.08 | 160 | 14.10 | 326 | 735 | 5.29 / 276.76 | 1 | 7 |
Average= | 4.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 23 | 14.41 | 502 | 166 | 0.17 / 266.55 | 1 | 2 |
2 | 7 | 2011.84 | 58 | 12.07 | 3428 | 2400 | 2.57 / 268.95 | 2 | 2 |
3 | 13 | 1475.00 | 32 | 12.98 | 2660 | 1105 | 3.67 / 270.05 | 1 | 2 |
4 | 13 | 787.20 | 32 | 13.50 | 1602 | 692 | 4.36 / 270.74 | 1 | 2 |
5 | 8 | -0.12 | 160 | 14.15 | 322 | 729 | 5.09 / 271.47 | 2 | 2 |
Average= | 4.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.24 | 23 | 14.43 | 484 | 161 | 0.16 / 261.22 | 1 | 2 |
2 | 7 | 2000.72 | 57 | 12.12 | 3411 | 2356 | 2.52 / 263.58 | 1 | 1 |
3 | 13 | 1566.40 | 32 | 12.93 | 2782 | 1151 | 3.67 / 264.73 | 1 | 2 |
4 | 13 | 862.96 | 32 | 13.45 | 1717 | 739 | 4.41 / 265.47 | 1 | 2 |
5 | 13 | 36.16 | 32 | 14.27 | 393 | 179 | 4.59 / 265.64 | 1 | 2 |
6 | 8 | -0.08 | 160 | 14.12 | 325 | 734 | 5.32 / 266.38 | 1 | 4 |
Average= | 4.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 23 | 14.39 | 493 | 163 | 0.16 / 256.12 | 2 | 2 |
2 | 7 | 2028.08 | 58 | 12.14 | 3454 | 2432 | 2.60 / 258.55 | 1 | 1 |
3 | 13 | 1510.20 | 32 | 12.97 | 2712 | 1126 | 3.72 / 259.68 | 1 | 2 |
4 | 13 | 704.88 | 32 | 13.58 | 1475 | 641 | 4.36 / 260.32 | 1 | 2 |
5 | 8 | -0.16 | 160 | 14.15 | 326 | 738 | 5.10 / 261.06 | 1 | 3 |
Average= | 4.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 23 | 14.41 | 484 | 160 | 0.16 / 250.99 | 1 | 2 |
2 | 7 | 2002.96 | 57 | 12.14 | 3406 | 2357 | 2.52 / 253.34 | 1 | 1 |
3 | 13 | 1682.92 | 32 | 12.86 | 2953 | 1215 | 3.73 / 254.56 | 1 | 2 |
4 | 13 | 744.16 | 32 | 13.54 | 1536 | 666 | 4.40 / 255.23 | 1 | 2 |
5 | 8 | 0.12 | 160 | 14.18 | 323 | 733 | 5.13 / 255.96 | 1 | 8 |
Average= | 4.83 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.12 | 23 | 14.41 | 495 | 164 | 0.16 / 246.02 | 2 | 2 |
2 | 7 | 2002.40 | 57 | 12.14 | 3412 | 2361 | 2.53 / 248.38 | 1 | 2 |
3 | 13 | 1470.48 | 32 | 12.99 | 2634 | 1095 | 3.62 / 249.47 | 1 | 2 |
4 | 13 | 675.28 | 32 | 13.61 | 1422 | 619 | 4.24 / 250.09 | 1 | 2 |
5 | 8 | 0.68 | 160 | 14.16 | 325 | 736 | 4.98 / 250.83 | 1 | 6 |
Average= | 4.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.28 | 23 | 14.43 | 481 | 160 | 0.16 / 240.97 | 1 | 2 |
2 | 7 | 2001.04 | 58 | 12.08 | 3410 | 2389 | 2.55 / 243.35 | 2 | 1 |
3 | 13 | 1579.32 | 32 | 12.89 | 2807 | 1158 | 3.71 / 244.51 | 1 | 3 |
4 | 13 | 655.36 | 32 | 13.65 | 1382 | 604 | 4.31 / 245.12 | 1 | 2 |
5 | 8 | 0.00 | 160 | 14.19 | 324 | 736 | 5.05 / 245.85 | 1 | 6 |
Average= | 4.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 23 | 14.42 | 479 | 159 | 0.16 / 236.02 | 2 | 2 |
2 | 7 | 2004.00 | 57 | 12.06 | 3411 | 2345 | 2.50 / 238.36 | 2 | 2 |
3 | 13 | 1471.04 | 32 | 12.97 | 2638 | 1095 | 3.60 / 239.46 | 1 | 2 |
4 | 13 | 671.00 | 32 | 13.64 | 1412 | 616 | 4.21 / 240.07 | 1 | 2 |
5 | 8 | 0.04 | 160 | 14.19 | 323 | 733 | 4.95 / 240.81 | 2 | 6 |
Average= | 4.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.76 | 23 | 14.42 | 482 | 160 | 0.16 / 230.78 | 1 | 2 |
2 | 3 | 973.60 | -1 | 15.24 | 0 | 0 | 0.00 / 230.78 | 1 | 2 |
3 | 7 | 2006.80 | 58 | 12.01 | 3419 | 2382 | 2.54 / 233.16 | 2 | 1 |
4 | 13 | 1581.08 | 32 | 12.87 | 2816 | 1160 | 3.70 / 234.32 | 1 | 3 |
5 | 13 | 986.52 | 32 | 13.33 | 1901 | 811 | 4.51 / 235.13 | 1 | 2 |
6 | 8 | 0.20 | 160 | 14.20 | 319 | 725 | 5.24 / 235.86 | 2 | 4 |
Average= | 4.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 23 | 14.44 | 489 | 162 | 0.16 / 225.73 | 1 | 2 |
2 | 7 | 2006.48 | 58 | 11.95 | 3420 | 2370 | 2.53 / 228.10 | 1 | 2 |
3 | 13 | 1589.52 | 32 | 12.84 | 2830 | 1163 | 3.70 / 229.26 | 1 | 3 |
4 | 13 | 697.84 | 32 | 13.59 | 1448 | 630 | 4.33 / 229.89 | 1 | 2 |
5 | 8 | 0.04 | 160 | 14.20 | 320 | 727 | 5.05 / 230.62 | 1 | 3 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.08 | 23 | 14.46 | 484 | 161 | 0.16 / 220.45 | 2 | 2 |
2 | 7 | 2005.68 | 57 | 11.89 | 3411 | 2312 | 2.47 / 222.76 | 1 | 1 |
3 | 13 | 1586.08 | 32 | 12.81 | 2819 | 1156 | 3.63 / 223.91 | 1 | 5 |
4 | 13 | 899.76 | 32 | 13.37 | 1776 | 760 | 4.39 / 224.67 | 1 | 2 |
5 | 13 | 30.04 | 32 | 14.32 | 378 | 173 | 4.56 / 224.85 | 1 | 2 |
6 | 8 | 0.04 | 160 | 14.17 | 319 | 723 | 5.28 / 225.57 | 1 | 5 |
Average= | 4.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.80 | 23 | 14.43 | 477 | 158 | 0.16 / 215.12 | 1 | 2 |
2 | 7 | 2022.96 | 58 | 11.90 | 3440 | 2374 | 2.53 / 217.49 | 1 | 2 |
3 | 13 | 1693.08 | 32 | 12.74 | 2975 | 1213 | 3.75 / 218.70 | 1 | 3 |
4 | 13 | 774.32 | 32 | 13.50 | 1573 | 680 | 4.42 / 219.38 | 1 | 2 |
5 | 13 | 30.40 | 32 | 14.32 | 378 | 173 | 4.60 / 219.56 | 1 | 2 |
6 | 8 | 0.04 | 160 | 14.18 | 321 | 728 | 5.33 / 220.28 | 2 | 4 |
Average= | 4.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.08 | 23 | 14.46 | 487 | 162 | 0.16 / 209.85 | 1 | 2 |
2 | 7 | 2006.56 | 58 | 11.91 | 3411 | 2356 | 2.52 / 212.21 | 2 | 1 |
3 | 13 | 1572.44 | 32 | 12.83 | 2793 | 1147 | 3.66 / 213.35 | 1 | 5 |
4 | 13 | 1084.20 | 32 | 13.22 | 2062 | 872 | 4.54 / 214.23 | 1 | 2 |
5 | 8 | 0.00 | 160 | 14.19 | 322 | 731 | 5.27 / 214.96 | 1 | 4 |
Average= | 4.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.00 | 23 | 14.46 | 493 | 164 | 0.16 / 204.68 | 1 | 2 |
2 | 3 | 966.36 | -1 | 15.22 | 0 | 0 | 0.00 / 204.68 | 1 | 2 |
3 | 7 | 2003.00 | 57 | 11.93 | 3417 | 2324 | 2.49 / 207.01 | 2 | 1 |
4 | 13 | 1683.72 | 32 | 12.77 | 2967 | 1212 | 3.70 / 208.22 | 1 | 3 |
5 | 13 | 856.12 | 32 | 13.42 | 1709 | 734 | 4.43 / 208.95 | 1 | 2 |
6 | 8 | 0.12 | 160 | 14.22 | 324 | 737 | 5.17 / 209.69 | 1 | 5 |
Average= | 4.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.40 | 23 | 14.48 | 506 | 169 | 0.17 / 199.59 | 1 | 2 |
2 | 3 | 1022.48 | 1 | 13.56 | 1965 | 27 | 0.20 / 199.61 | 1 | 1 |
3 | 3 | 1033.48 | 1 | 13.72 | 1964 | 27 | 0.22 / 199.64 | 1 | 1 |
4 | 7 | 1807.48 | 57 | 12.12 | 3129 | 2162 | 2.38 / 201.80 | 1 | 1 |
5 | 13 | 1714.24 | 32 | 12.62 | 3002 | 1212 | 3.60 / 203.01 | 1 | 3 |
6 | 13 | 878.00 | 32 | 13.41 | 1744 | 748 | 4.34 / 203.76 | 1 | 2 |
7 | 8 | 0.00 | 160 | 14.19 | 333 | 756 | 5.10 / 204.52 | 1 | 5 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.16 | 23 | 14.48 | 496 | 165 | 0.17 / 194.30 | 1 | 2 |
2 | 7 | 2001.76 | 57 | 12.04 | 3414 | 2343 | 2.51 / 196.64 | 2 | 1 |
3 | 13 | 1484.16 | 32 | 12.98 | 2680 | 1113 | 3.62 / 197.75 | 1 | 2 |
4 | 13 | 1120.16 | 32 | 13.26 | 2130 | 904 | 4.53 / 198.66 | 1 | 2 |
5 | 8 | -0.12 | 160 | 14.21 | 335 | 762 | 5.29 / 199.42 | 1 | 4 |
Average= | 4.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.16 | 22 | 14.52 | 500 | 160 | 0.16 / 189.15 | 1 | 2 |
2 | 3 | 1031.88 | 1 | 13.94 | 1954 | 27 | 0.19 / 189.18 | 1 | 1 |
3 | 3 | 1020.68 | 1 | 13.56 | 1970 | 27 | 0.21 / 189.20 | 1 | 1 |
4 | 7 | 2006.64 | 58 | 12.11 | 3424 | 2405 | 2.62 / 191.61 | 1 | 1 |
5 | 13 | 1556.60 | 32 | 12.97 | 2777 | 1153 | 3.77 / 192.76 | 1 | 2 |
6 | 13 | 640.72 | 32 | 13.71 | 1378 | 605 | 4.38 / 193.37 | 1 | 2 |
7 | 8 | 0.28 | 160 | 14.22 | 336 | 764 | 5.14 / 194.13 | 1 | 3 |
Average= | 4.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.52 | 23 | 14.50 | 492 | 164 | 0.16 / 184.05 | 2 | 2 |
2 | 3 | 963.00 | -1 | 15.20 | 0 | 0 | 0.00 / 184.05 | 2 | 2 |
3 | 7 | 2004.76 | 50 | 12.23 | 3423 | 2093 | 2.26 / 186.14 | 2 | 1 |
4 | 13 | 1907.12 | 32 | 12.65 | 3299 | 1335 | 3.59 / 187.48 | 1 | 1 |
5 | 13 | 856.96 | 32 | 13.52 | 1715 | 742 | 4.33 / 188.22 | 1 | 2 |
6 | 8 | -0.16 | 160 | 14.24 | 339 | 772 | 5.11 / 188.99 | 2 | 2 |
Average= | 4.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.20 | 22 | 14.53 | 503 | 161 | 0.16 / 178.78 | 1 | 2 |
2 | 7 | 2005.24 | 50 | 12.33 | 3427 | 2113 | 2.27 / 180.89 | 1 | 1 |
3 | 13 | 1699.04 | 32 | 12.95 | 2999 | 1243 | 3.52 / 182.13 | 1 | 2 |
4 | 13 | 889.68 | 32 | 13.53 | 1771 | 767 | 4.28 / 182.90 | 1 | 2 |
5 | 13 | 64.44 | 32 | 14.37 | 449 | 206 | 4.49 / 183.11 | 1 | 2 |
6 | 8 | 0.24 | 160 | 14.23 | 342 | 779 | 5.27 / 183.88 | 1 | 6 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.04 | 22 | 14.54 | 514 | 164 | 0.16 / 173.61 | 1 | 2 |
2 | 7 | 2007.92 | 49 | 12.42 | 3432 | 2089 | 2.25 / 175.69 | 1 | 1 |
3 | 13 | 1908.04 | 32 | 12.77 | 3306 | 1351 | 3.60 / 177.05 | 1 | 3 |
4 | 13 | 953.16 | 32 | 13.51 | 1870 | 808 | 4.41 / 177.85 | 1 | 2 |
5 | 8 | 0.40 | 160 | 14.29 | 333 | 761 | 5.17 / 178.62 | 1 | 3 |
Average= | 4.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.88 | 22 | 14.55 | 510 | 163 | 0.16 / 168.43 | 1 | 2 |
2 | 7 | 2003.20 | 50 | 12.41 | 3421 | 2123 | 2.29 / 170.55 | 1 | 1 |
3 | 13 | 1902.84 | 32 | 12.78 | 3299 | 1349 | 3.64 / 171.90 | 1 | 2 |
4 | 13 | 881.52 | 32 | 13.58 | 1752 | 761 | 4.40 / 172.66 | 1 | 2 |
5 | 8 | 0.44 | 160 | 14.27 | 342 | 781 | 5.18 / 173.44 | 1 | 2 |
Average= | 4.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.24 | 22 | 14.55 | 516 | 165 | 0.17 / 163.34 | 1 | 2 |
2 | 7 | 2001.44 | 49 | 12.45 | 3423 | 2088 | 2.25 / 165.43 | 1 | 1 |
3 | 13 | 1795.72 | 32 | 12.96 | 3138 | 1301 | 3.55 / 166.73 | 1 | 3 |
4 | 13 | 861.00 | 32 | 13.61 | 1725 | 751 | 4.31 / 167.48 | 1 | 2 |
5 | 8 | 0.20 | 160 | 14.28 | 342 | 781 | 5.09 / 168.26 | 1 | 3 |
Average= | 4.67 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.96 | 22 | 14.54 | 506 | 162 | 0.16 / 158.15 | 1 | 2 |
2 | 7 | 2003.92 | 50 | 12.48 | 3428 | 2139 | 2.30 / 160.29 | 2 | 1 |
3 | 13 | 1798.12 | 32 | 12.98 | 3149 | 1308 | 3.61 / 161.60 | 1 | 2 |
4 | 13 | 951.28 | 32 | 13.56 | 1862 | 808 | 4.42 / 162.41 | 1 | 2 |
5 | 8 | -0.08 | 160 | 14.30 | 337 | 771 | 5.19 / 163.18 | 1 | 7 |
Average= | 4.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.76 | 22 | 14.56 | 517 | 166 | 0.17 / 153.14 | 1 | 2 |
2 | 7 | 2001.92 | 50 | 12.53 | 3428 | 2148 | 2.31 / 155.28 | 2 | 1 |
3 | 13 | 1563.12 | 32 | 13.15 | 2795 | 1176 | 3.49 / 156.46 | 1 | 2 |
4 | 13 | 872.40 | 32 | 13.64 | 1731 | 756 | 4.24 / 157.22 | 1 | 2 |
5 | 8 | 0.36 | 160 | 14.30 | 338 | 773 | 5.02 / 157.99 | 1 | 5 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.72 | 22 | 14.57 | 522 | 167 | 0.17 / 148.23 | 1 | 2 |
2 | 7 | 2001.76 | 49 | 12.54 | 3421 | 2102 | 2.27 / 150.33 | 1 | 2 |
3 | 13 | 1494.92 | 32 | 13.19 | 2689 | 1135 | 3.40 / 151.47 | 1 | 1 |
4 | 13 | 818.12 | 32 | 13.69 | 1660 | 727 | 4.13 / 152.19 | 1 | 2 |
5 | 8 | 0.00 | 160 | 14.31 | 339 | 776 | 4.91 / 152.97 | 1 | 4 |
Average= | 4.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.32 | 22 | 14.56 | 522 | 167 | 0.17 / 143.26 | 1 | 2 |
2 | 7 | 2002.60 | 50 | 12.59 | 3418 | 2152 | 2.32 / 145.41 | 2 | 2 |
3 | 13 | 1496.44 | 32 | 13.21 | 2691 | 1138 | 3.46 / 146.55 | 1 | 2 |
4 | 13 | 837.12 | 32 | 13.68 | 1682 | 736 | 4.19 / 147.28 | 1 | 2 |
5 | 8 | 0.24 | 160 | 14.32 | 341 | 781 | 4.97 / 148.06 | 1 | 3 |
Average= | 4.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.84 | 22 | 14.57 | 507 | 163 | 0.16 / 138.13 | 1 | 2 |
2 | 3 | 1022.84 | 1 | 14.20 | 1938 | 28 | 0.19 / 138.15 | 1 | 1 |
3 | 7 | 2002.44 | 49 | 12.61 | 3431 | 2120 | 2.31 / 140.27 | 1 | 2 |
4 | 13 | 1694.16 | 32 | 13.09 | 2995 | 1255 | 3.56 / 141.53 | 1 | 2 |
5 | 13 | 896.32 | 32 | 13.64 | 1785 | 779 | 4.34 / 142.31 | 1 | 2 |
6 | 8 | -0.04 | 160 | 14.32 | 341 | 781 | 5.12 / 143.09 | 1 | 3 |
Average= | 4.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.80 | 23 | 14.59 | 499 | 167 | 0.17 / 133.17 | 1 | 2 |
2 | 3 | 958.76 | -1 | 15.28 | 0 | 0 | 0.00 / 133.17 | 1 | 2 |
3 | 7 | 2000.16 | 45 | 12.70 | 3422 | 1956 | 2.12 / 135.12 | 1 | 1 |
4 | 13 | 1789.64 | 24 | 13.13 | 3152 | 993 | 3.12 / 136.12 | 1 | 3 |
5 | 13 | 1131.16 | 24 | 13.55 | 2152 | 700 | 3.82 / 136.82 | 1 | 2 |
6 | 13 | 546.68 | 24 | 14.02 | 1230 | 414 | 4.23 / 137.23 | 1 | 3 |
7 | 8 | 0.32 | 150 | 14.33 | 341 | 733 | 4.96 / 137.96 | 1 | 4 |
Average= | 4.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.12 | 22 | 14.58 | 516 | 166 | 0.17 / 127.96 | 1 | 2 |
2 | 7 | 2002.36 | 45 | 12.72 | 3423 | 1959 | 2.12 / 129.92 | 1 | 1 |
3 | 13 | 1794.40 | 35 | 13.00 | 3141 | 1429 | 3.55 / 131.35 | 1 | 4 |
4 | 13 | 758.40 | 35 | 13.73 | 1560 | 750 | 4.30 / 132.10 | 1 | 2 |
5 | 13 | 8.84 | 35 | 14.51 | 359 | 182 | 4.49 / 132.28 | 1 | 2 |
6 | 8 | 0.00 | 150 | 14.28 | 337 | 722 | 5.21 / 133.00 | 1 | 5 |
Average= | 4.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.68 | 22 | 14.59 | 513 | 165 | 0.16 / 122.87 | 1 | 2 |
2 | 7 | 2003.48 | 45 | 12.76 | 3438 | 1974 | 2.14 / 124.84 | 2 | 2 |
3 | 13 | 1706.04 | 35 | 13.07 | 3010 | 1377 | 3.52 / 126.22 | 1 | 2 |
4 | 13 | 883.52 | 35 | 13.63 | 1767 | 843 | 4.36 / 127.06 | 1 | 2 |
5 | 8 | 0.08 | 150 | 14.33 | 340 | 731 | 5.09 / 127.79 | 1 | 5 |
Average= | 4.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.60 | 22 | 14.57 | 515 | 165 | 0.17 / 117.77 | 2 | 2 |
2 | 7 | 1993.92 | 45 | 12.80 | 3423 | 1972 | 2.14 / 119.74 | 1 | 2 |
3 | 13 | 1795.08 | 35 | 13.02 | 3143 | 1432 | 3.57 / 121.17 | 1 | 2 |
4 | 13 | 837.84 | 35 | 13.69 | 1678 | 804 | 4.37 / 121.98 | 1 | 2 |
5 | 8 | -0.24 | 150 | 14.35 | 337 | 725 | 5.10 / 122.70 | 1 | 7 |
Average= | 4.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.52 | 22 | 14.58 | 509 | 163 | 0.16 / 112.91 | 1 | 2 |
2 | 7 | 2000.72 | 46 | 12.81 | 3435 | 2024 | 2.19 / 114.93 | 1 | 1 |
3 | 13 | 1594.76 | 35 | 13.15 | 2838 | 1306 | 3.49 / 116.24 | 1 | 2 |
4 | 13 | 600.56 | 35 | 13.91 | 1307 | 636 | 4.13 / 116.88 | 1 | 2 |
5 | 8 | 0.24 | 150 | 14.36 | 338 | 728 | 4.86 / 117.61 | 2 | 4 |
Average= | 4.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.28 | 22 | 14.58 | 512 | 164 | 0.16 / 107.91 | 1 | 2 |
2 | 7 | 2000.68 | 45 | 12.82 | 3429 | 1978 | 2.14 / 109.89 | 1 | 1 |
3 | 13 | 1696.00 | 35 | 13.10 | 2995 | 1373 | 3.52 / 111.26 | 1 | 4 |
4 | 13 | 772.52 | 35 | 13.75 | 1580 | 760 | 4.28 / 112.02 | 1 | 2 |
5 | 8 | 0.16 | 150 | 14.35 | 338 | 728 | 5.00 / 112.75 | 2 | 4 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.20 | 22 | 14.61 | 487 | 157 | 0.16 / 103.06 | 2 | 2 |
2 | 7 | 2004.64 | 46 | 12.83 | 3447 | 2034 | 2.19 / 105.10 | 1 | 1 |
3 | 13 | 1614.80 | 35 | 13.16 | 2882 | 1327 | 3.52 / 106.42 | 1 | 2 |
4 | 13 | 532.32 | 35 | 13.99 | 1200 | 588 | 4.11 / 107.01 | 1 | 2 |
5 | 8 | 0.32 | 150 | 14.35 | 340 | 732 | 4.84 / 107.74 | 1 | 3 |
Average= | 4.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.36 | 22 | 14.59 | 498 | 160 | 0.16 / 98.57 | 1 | 2 |
2 | 7 | 2000.88 | 45 | 12.85 | 3437 | 1987 | 2.15 / 100.56 | 1 | 2 |
3 | 13 | 1413.24 | 35 | 13.28 | 2574 | 1196 | 3.34 / 101.75 | 1 | 2 |
4 | 13 | 310.16 | 35 | 14.22 | 845 | 421 | 3.76 / 102.17 | 1 | 2 |
5 | 8 | 0.08 | 150 | 14.35 | 341 | 734 | 4.50 / 102.91 | 2 | 6 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.16 | 22 | 14.60 | 498 | 160 | 0.16 / 93.80 | 1 | 2 |
2 | 7 | 2002.76 | 45 | 12.87 | 3435 | 1989 | 2.15 / 95.79 | 2 | 1 |
3 | 13 | 1415.44 | 35 | 13.28 | 2571 | 1195 | 3.34 / 96.99 | 1 | 2 |
4 | 13 | 666.76 | 35 | 13.85 | 1418 | 687 | 4.03 / 97.68 | 1 | 2 |
5 | 8 | -0.16 | 150 | 14.35 | 340 | 732 | 4.76 / 98.41 | 1 | 2 |
Average= | 4.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.48 | 23 | 14.59 | 489 | 164 | 0.16 / 88.99 | 1 | 2 |
2 | 3 | 972.68 | -1 | 15.37 | 0 | 0 | 0.00 / 88.99 | 1 | 2 |
3 | 3 | 1027.92 | 1 | 14.30 | 1968 | 28 | 0.19 / 89.01 | 1 | 1 |
4 | 7 | 2000.76 | 46 | 12.87 | 3438 | 2035 | 2.23 / 91.05 | 1 | 2 |
5 | 13 | 1694.72 | 35 | 13.13 | 2998 | 1378 | 3.61 / 92.43 | 1 | 2 |
6 | 13 | 401.96 | 35 | 14.13 | 993 | 491 | 4.10 / 92.92 | 1 | 2 |
7 | 8 | -0.08 | 150 | 14.36 | 337 | 726 | 4.82 / 93.64 | 1 | 3 |
Average= | 4.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.52 | 23 | 14.61 | 492 | 165 | 0.17 / 84.10 | 2 | 2 |
2 | 7 | 1995.44 | 45 | 12.89 | 3425 | 1987 | 2.15 / 86.09 | 2 | 2 |
3 | 13 | 1515.00 | 35 | 13.22 | 2723 | 1260 | 3.41 / 87.35 | 1 | 2 |
4 | 13 | 744.12 | 35 | 13.79 | 1538 | 742 | 4.15 / 88.09 | 1 | 2 |
5 | 8 | 0.36 | 150 | 14.36 | 339 | 730 | 4.88 / 88.82 | 1 | 6 |
Average= | 4.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 22 | 14.65 | 485 | 156 | 0.16 / 79.29 | 2 | 2 |
2 | 3 | 1058.72 | 1 | 14.42 | 2038 | 29 | 0.19 / 79.31 | 1 | 1 |
3 | 7 | 1992.00 | 45 | 12.91 | 3431 | 1993 | 2.18 / 81.31 | 1 | 2 |
4 | 13 | 1592.60 | 35 | 13.19 | 2834 | 1308 | 3.49 / 82.62 | 1 | 2 |
5 | 13 | 527.12 | 35 | 14.01 | 1192 | 584 | 4.07 / 83.20 | 1 | 2 |
6 | 8 | 0.08 | 150 | 14.36 | 342 | 737 | 4.81 / 83.94 | 1 | 5 |
Average= | 4.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.48 | 22 | 14.66 | 495 | 160 | 0.16 / 74.62 | 2 | 2 |
2 | 7 | 2007.84 | 45 | 12.88 | 3443 | 1996 | 2.16 / 76.62 | 1 | 2 |
3 | 13 | 1511.04 | 35 | 13.24 | 2725 | 1263 | 3.42 / 77.88 | 1 | 2 |
4 | 13 | 453.84 | 35 | 14.10 | 1073 | 530 | 3.95 / 78.41 | 1 | 2 |
5 | 8 | -0.08 | 150 | 14.40 | 333 | 719 | 4.67 / 79.13 | 1 | 3 |
Average= | 4.40 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.32 | 22 | 14.69 | 484 | 156 | 0.16 / 69.75 | 2 | 2 |
2 | 7 | 2006.88 | 45 | 12.89 | 3449 | 2001 | 2.16 / 71.75 | 1 | 1 |
3 | 13 | 1474.52 | 35 | 13.27 | 2666 | 1238 | 3.40 / 72.99 | 1 | 2 |
4 | 13 | 471.32 | 35 | 14.08 | 1105 | 545 | 3.94 / 73.53 | 1 | 2 |
5 | 8 | -0.04 | 190 | 14.36 | 340 | 928 | 4.87 / 74.46 | 1 | 4 |
Average= | 4.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.28 | 22 | 14.69 | 479 | 155 | 0.15 / 64.87 | 2 | 2 |
2 | 7 | 2001.16 | 46 | 12.90 | 3441 | 2042 | 2.20 / 66.91 | 1 | 2 |
3 | 13 | 1375.40 | 35 | 13.33 | 2512 | 1172 | 3.37 / 68.08 | 1 | 2 |
4 | 13 | 529.24 | 35 | 14.01 | 1196 | 586 | 3.96 / 68.67 | 1 | 2 |
5 | 8 | -0.12 | 190 | 14.35 | 340 | 927 | 4.88 / 69.59 | 1 | 4 |
Average= | 4.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.52 | 22 | 14.70 | 495 | 160 | 0.16 / 59.73 | 2 | 2 |
2 | 3 | 1022.24 | 1 | 14.39 | 1964 | 28 | 0.19 / 59.76 | 1 | 1 |
3 | 7 | 2000.52 | 46 | 12.91 | 3444 | 2045 | 2.23 / 61.80 | 1 | 2 |
4 | 13 | 1490.72 | 35 | 13.27 | 2692 | 1250 | 3.48 / 63.05 | 1 | 2 |
5 | 13 | 746.00 | 35 | 13.81 | 1538 | 743 | 4.23 / 63.80 | 1 | 2 |
6 | 8 | -0.08 | 190 | 14.36 | 336 | 917 | 5.14 / 64.71 | 1 | 4 |
Average= | 4.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.56 | 22 | 14.70 | 496 | 160 | 0.16 / 55.15 | 2 | 2 |
2 | 7 | 2002.52 | 46 | 12.92 | 3438 | 2043 | 2.20 / 57.19 | 1 | 2 |
3 | 13 | 1595.16 | 21 | 13.40 | 2854 | 803 | 3.01 / 57.99 | 1 | 2 |
4 | 13 | 913.28 | 21 | 13.83 | 1812 | 526 | 3.53 / 58.52 | 1 | 2 |
5 | 13 | 65.04 | 21 | 14.60 | 454 | 139 | 3.67 / 58.66 | 1 | 2 |
6 | 8 | -0.08 | 190 | 14.36 | 334 | 911 | 4.58 / 59.57 | 1 | 4 |
Average= | 4.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.28 | 22 | 14.70 | 487 | 157 | 0.16 / 50.37 | 2 | 2 |
2 | 7 | 2003.04 | 46 | 12.89 | 3439 | 2039 | 2.20 / 52.41 | 2 | 2 |
3 | 13 | 1598.32 | 21 | 13.39 | 2871 | 807 | 3.00 / 53.22 | 1 | 1 |
4 | 13 | 1043.68 | 21 | 13.73 | 2026 | 584 | 3.59 / 53.80 | 1 | 2 |
5 | 13 | 103.16 | 21 | 14.55 | 520 | 159 | 3.75 / 53.96 | 1 | 2 |
6 | 13 | 19.88 | 21 | 14.62 | 379 | 116 | 3.86 / 54.08 | 1 | 2 |
7 | 8 | 0.04 | 190 | 14.34 | 334 | 910 | 4.77 / 54.99 | 1 | 5 |
Average= | 4.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 22 | 14.69 | 508 | 164 | 0.16 / 45.81 | 2 | 2 |
2 | 7 | 1992.52 | 46 | 12.89 | 3428 | 2033 | 2.20 / 47.85 | 2 | 2 |
3 | 13 | 1483.04 | 21 | 13.44 | 2692 | 760 | 2.96 / 48.61 | 1 | 2 |
4 | 13 | 956.08 | 21 | 13.78 | 1890 | 547 | 3.50 / 49.15 | 1 | 2 |
5 | 13 | 70.24 | 21 | 14.59 | 463 | 142 | 3.65 / 49.30 | 1 | 2 |
6 | 8 | -0.04 | 190 | 14.36 | 336 | 917 | 4.56 / 50.21 | 1 | 2 |
Average= | 4.18 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 21 | 14.70 | 493 | 152 | 0.15 / 41.22 | 2 | 2 |
2 | 3 | 1024.72 | 1 | 14.42 | 1981 | 29 | 0.18 / 41.25 | 1 | 1 |
3 | 7 | 1994.48 | 46 | 12.88 | 3432 | 2033 | 2.21 / 43.28 | 1 | 2 |
4 | 13 | 1604.36 | 21 | 13.37 | 2870 | 806 | 3.02 / 44.09 | 1 | 2 |
5 | 13 | 836.36 | 21 | 13.87 | 1699 | 495 | 3.51 / 44.58 | 1 | 2 |
6 | 13 | 79.60 | 21 | 14.58 | 481 | 147 | 3.66 / 44.73 | 1 | 2 |
7 | 8 | 0.00 | 190 | 14.35 | 338 | 922 | 4.58 / 45.65 | 1 | 8 |
Average= | 4.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 21 | 14.68 | 506 | 156 | 0.16 / 36.40 | 2 | 2 |
2 | 7 | 1994.40 | 45 | 12.89 | 3431 | 1990 | 2.15 / 38.39 | 1 | 2 |
3 | 13 | 1482.16 | 26 | 13.35 | 2677 | 929 | 3.08 / 39.32 | 1 | 2 |
4 | 13 | 927.24 | 26 | 13.73 | 1831 | 654 | 3.73 / 39.97 | 1 | 2 |
5 | 13 | 76.12 | 26 | 14.56 | 474 | 179 | 3.91 / 40.15 | 1 | 2 |
6 | 8 | -0.12 | 190 | 14.34 | 336 | 915 | 4.82 / 41.07 | 1 | 6 |
Average= | 4.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.20 | 21 | 14.68 | 505 | 156 | 0.16 / 31.65 | 2 | 2 |
2 | 7 | 1993.44 | 45 | 12.85 | 3428 | 1982 | 2.14 / 33.63 | 1 | 2 |
3 | 13 | 1597.24 | 26 | 13.27 | 2852 | 984 | 3.12 / 34.61 | 1 | 2 |
4 | 13 | 768.12 | 26 | 13.85 | 1582 | 570 | 3.69 / 35.18 | 1 | 2 |
5 | 13 | 17.60 | 26 | 14.64 | 375 | 143 | 3.83 / 35.33 | 1 | 2 |
6 | 8 | -0.08 | 190 | 14.33 | 336 | 915 | 4.75 / 36.24 | 1 | 7 |
Average= | 4.03 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 21 | 14.68 | 502 | 155 | 0.15 / 26.87 | 1 | 2 |
2 | 7 | 1998.84 | 45 | 12.85 | 3431 | 1984 | 2.14 / 28.85 | 1 | 1 |
3 | 13 | 1486.32 | 26 | 13.31 | 2693 | 932 | 3.07 / 29.79 | 1 | 1 |
4 | 13 | 928.24 | 26 | 13.71 | 1828 | 652 | 3.72 / 30.44 | 1 | 2 |
5 | 13 | 17.52 | 26 | 14.65 | 375 | 143 | 3.87 / 30.58 | 1 | 2 |
6 | 8 | 0.04 | 190 | 14.30 | 336 | 913 | 4.78 / 31.49 | 2 | 3 |
Average= | 3.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.36 | 21 | 14.68 | 501 | 154 | 0.15 / 22.33 | 2 | 2 |
2 | 7 | 1991.84 | 46 | 12.81 | 3419 | 2015 | 2.17 / 24.35 | 1 | 2 |
3 | 13 | 1486.92 | 26 | 13.29 | 2685 | 928 | 3.10 / 25.28 | 1 | 2 |
4 | 13 | 686.48 | 26 | 13.92 | 1443 | 522 | 3.62 / 25.80 | 1 | 2 |
5 | 8 | 0.08 | 190 | 14.37 | 336 | 917 | 4.54 / 26.72 | 1 | 4 |
Average= | 3.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.24 | 24 | 14.66 | 493 | 173 | 0.17 / 17.74 | 1 | 2 |
2 | 3 | 799.32 | -4 | 15.44 | 0 | 0 | 0.00 / 17.74 | 1 | 2 |
3 | 3 | 1020.56 | 1 | 14.38 | 1928 | 28 | 0.20 / 17.76 | 1 | 1 |
4 | 7 | 1990.36 | 46 | 12.80 | 3420 | 2014 | 2.21 / 19.78 | 1 | 2 |
5 | 13 | 1463.72 | 26 | 13.28 | 2654 | 916 | 3.13 / 20.69 | 1 | 1 |
6 | 13 | 798.12 | 26 | 13.80 | 1616 | 580 | 3.71 / 21.27 | 1 | 2 |
7 | 8 | 0.12 | 190 | 14.38 | 331 | 904 | 4.62 / 22.18 | 2 | 4 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.68 | 20 | 14.66 | 509 | 149 | 0.15 / 13.37 | 2 | 2 |
2 | 7 | 1510.60 | 74 | 13.02 | 2690 | 2592 | 2.74 / 15.97 | 1 | 1 |
3 | 13 | 647.76 | 25 | 13.98 | 1374 | 480 | 3.22 / 16.45 | 1 | 2 |
4 | 8 | 0.04 | 240 | 14.33 | 325 | 1118 | 4.34 / 17.56 | 1 | 5 |
Average= | 3.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.04 | 21 | 14.61 | 508 | 156 | 0.16 / 9.10 | 2 | 2 |
2 | 3 | 960.80 | -1 | 15.44 | 0 | 0 | 0.00 / 9.10 | 2 | 2 |
3 | 7 | 1511.00 | 75 | 12.96 | 2687 | 2612 | 2.77 / 11.71 | 1 | 2 |
4 | 13 | 511.56 | 25 | 14.08 | 1155 | 407 | 3.17 / 12.12 | 1 | 2 |
5 | 8 | 0.08 | 240 | 14.31 | 322 | 1106 | 4.28 / 13.22 | 1 | 4 |
Average= | 3.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.12 | 24 | 14.55 | 484 | 169 | 0.17 / 4.88 | 1 | 2 |
2 | 3 | 803.16 | -4 | 15.43 | 0 | 0 | 0.00 / 4.88 | 1 | 2 |
3 | 3 | 1019.64 | 1 | 14.17 | 1921 | 27 | 0.20 / 4.90 | 1 | 2 |
4 | 7 | 1505.28 | 74 | 12.84 | 2672 | 2539 | 2.74 / 7.44 | 2 | 2 |
5 | 13 | 533.56 | 25 | 14.00 | 1183 | 414 | 3.15 / 7.86 | 1 | 2 |
6 | 8 | 0.16 | 240 | 14.29 | 317 | 1087 | 4.24 / 8.94 | 2 | 3 |
Average= | 2.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.04 | 24 | 14.44 | 466 | 161 | 0.16 / 1.72 | 2 | 2 |
2 | 3 | 847.48 | -3 | 15.40 | 0 | 0 | 0.00 / 1.72 | 2 | 2 |
3 | 3 | 1037.20 | 1 | 13.56 | 1926 | 26 | 0.19 / 1.75 | 1 | 1 |
4 | 7 | 1029.88 | 75 | 13.01 | 1930 | 1883 | 2.07 / 3.63 | 1 | 2 |
5 | 8 | 0.04 | 240 | 14.23 | 315 | 1076 | 3.15 / 4.71 | 2 | 6 |
Average= | 2.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 82.96 | 24 | 14.22 | 389 | 133 | 0.13 / 0.13 | 2 | 2 |
2 | 7 | 92.64 | 74 | 14.02 | 434 | 450 | 0.58 / 0.58 | 2 | 2 |
3 | 8 | 0.32 | 240 | 14.25 | 286 | 978 | 1.56 / 1.56 | 2 | 4 |
Average= | 1.56 (KJ/cycle) |