SIO Argo Site:
Diagnostic/Engineering Data Page    



Serial= 6126 WMO= 7901078

Return

Link to Fleet Monitoring (Coriolis)


←PreviousNext→

diagP0 values highlighted red are cycles with likely grounding of the passive bottom detection system


Cycle -1 GMT 29/10/2024 1: 2:59

#Eng #Pack BTPCor (db) BTVcpu (V) BTVpmp (V) BTVple (V) BTavgl (mA) BTPsec (s) BTOVcb BTOVca BTvac (inHG) BTvacI (inHG) BTRH (%)
7 6 0.9 7.24 15.47 15.16 426.00 673 2 103 10.24 11.15 64


CTDSN BTSpt (txt) BTOV BTCV BTInt Fail
6007 "-0.9,15.2823,0.008____________" 0 0 6 0