SIO Argo Site:
|
|
|
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 116.12 | 31 | 15.08 | 401 | 187 | 0.19 / 101.39 | 2 | 3 |
| 2 | 7 | 2006.96 | 38 | 14.74 | 2724 | 1526 | 1.71 / 102.91 | 2 | 5 |
| 3 | 13 | 1349.72 | 18 | 14.82 | 1970 | 526 | 2.24 / 103.44 | 2 | 6 |
| 4 | 13 | 770.48 | 18 | 14.94 | 1261 | 339 | 2.58 / 103.78 | 2 | 7 |
| 5 | 13 | 214.04 | 18 | 15.08 | 546 | 148 | 2.73 / 103.92 | 2 | 4 |
| 6 | 8 | 0.08 | 165 | 15.10 | 261 | 650 | 3.38 / 104.57 | 2 | 16 |
| Average= | 3.37 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 113.24 | 31 | 15.08 | 409 | 191 | 0.19 / 98.02 | 2 | 3 |
| 2 | 7 | 2010.64 | 38 | 14.74 | 2724 | 1526 | 1.72 / 99.55 | 2 | 5 |
| 3 | 13 | 1302.52 | 18 | 14.83 | 1920 | 513 | 2.23 / 100.06 | 2 | 6 |
| 4 | 13 | 826.16 | 18 | 14.93 | 1328 | 357 | 2.59 / 100.42 | 2 | 8 |
| 5 | 13 | 243.08 | 18 | 15.09 | 579 | 157 | 2.74 / 100.57 | 2 | 5 |
| 6 | 8 | 0.16 | 165 | 15.12 | 251 | 626 | 3.37 / 101.20 | 2 | 16 |
| Average= | 3.37 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 115.88 | 31 | 15.09 | 400 | 187 | 0.19 / 94.58 | 2 | 3 |
| 2 | 7 | 2005.92 | 39 | 14.75 | 2720 | 1565 | 1.75 / 96.15 | 2 | 5 |
| 3 | 13 | 1343.64 | 18 | 14.83 | 1962 | 524 | 2.28 / 96.67 | 2 | 6 |
| 4 | 13 | 849.00 | 18 | 14.92 | 1365 | 367 | 2.64 / 97.04 | 2 | 8 |
| 5 | 13 | 194.40 | 18 | 15.11 | 522 | 142 | 2.78 / 97.18 | 2 | 4 |
| 6 | 8 | 0.24 | 165 | 15.11 | 260 | 648 | 3.43 / 97.83 | 2 | 14 |
| Average= | 3.37 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 113.96 | 31 | 15.08 | 399 | 187 | 0.19 / 91.18 | 2 | 3 |
| 2 | 7 | 2008.40 | 38 | 14.75 | 2721 | 1525 | 1.71 / 92.71 | 2 | 3 |
| 3 | 13 | 1352.96 | 18 | 14.84 | 1965 | 525 | 2.24 / 93.23 | 2 | 5 |
| 4 | 13 | 830.00 | 18 | 14.93 | 1328 | 357 | 2.59 / 93.59 | 2 | 8 |
| 5 | 13 | 272.40 | 18 | 15.08 | 610 | 166 | 2.76 / 93.76 | 2 | 4 |
| 6 | 8 | 0.00 | 165 | 15.12 | 257 | 641 | 3.40 / 94.40 | 2 | 13 |
| Average= | 3.37 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 116.72 | 31 | 15.08 | 412 | 193 | 0.19 / 87.76 | 2 | 3 |
| 2 | 7 | 2006.40 | 39 | 14.75 | 2714 | 1561 | 1.75 / 89.32 | 2 | 3 |
| 3 | 13 | 1345.20 | 18 | 14.83 | 1952 | 521 | 2.27 / 89.84 | 2 | 8 |
| 4 | 13 | 850.80 | 18 | 14.93 | 1357 | 365 | 2.64 / 90.21 | 2 | 8 |
| 5 | 13 | 185.52 | 18 | 15.11 | 508 | 138 | 2.78 / 90.35 | 2 | 4 |
| 6 | 8 | 0.28 | 165 | 15.11 | 261 | 651 | 3.43 / 91.00 | 2 | 16 |
| Average= | 3.37 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 104.84 | 31 | 15.08 | 384 | 180 | 0.18 / 84.33 | 2 | 3 |
| 2 | 7 | 2008.68 | 38 | 14.76 | 2731 | 1532 | 1.71 / 85.86 | 2 | 4 |
| 3 | 13 | 1434.08 | 18 | 14.81 | 2062 | 550 | 2.26 / 86.41 | 2 | 7 |
| 4 | 13 | 879.96 | 18 | 14.91 | 1393 | 374 | 2.63 / 86.78 | 2 | 7 |
| 5 | 13 | 219.92 | 18 | 15.09 | 543 | 147 | 2.78 / 86.93 | 2 | 4 |
| 6 | 8 | 0.04 | 165 | 15.12 | 256 | 639 | 3.42 / 87.57 | 2 | 16 |
| Average= | 3.37 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 113.92 | 31 | 15.10 | 408 | 191 | 0.19 / 80.90 | 2 | 3 |
| 2 | 7 | 2009.52 | 38 | 14.76 | 2732 | 1532 | 1.72 / 82.44 | 2 | 5 |
| 3 | 13 | 1413.80 | 18 | 14.82 | 2048 | 546 | 2.27 / 82.98 | 2 | 7 |
| 4 | 13 | 858.44 | 18 | 14.92 | 1370 | 368 | 2.64 / 83.35 | 2 | 7 |
| 5 | 13 | 247.12 | 18 | 15.09 | 585 | 159 | 2.80 / 83.51 | 2 | 5 |
| 6 | 8 | 0.16 | 165 | 15.13 | 255 | 637 | 3.43 / 84.15 | 2 | 13 |
| Average= | 3.37 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 114.28 | 31 | 15.11 | 398 | 186 | 0.19 / 77.48 | 2 | 3 |
| 2 | 7 | 2011.92 | 38 | 14.75 | 2741 | 1536 | 1.72 / 79.01 | 2 | 4 |
| 3 | 13 | 1352.80 | 18 | 14.84 | 1978 | 528 | 2.25 / 79.54 | 2 | 5 |
| 4 | 13 | 862.48 | 18 | 14.94 | 1385 | 372 | 2.62 / 79.91 | 2 | 8 |
| 5 | 13 | 237.68 | 18 | 15.11 | 571 | 155 | 2.78 / 80.07 | 2 | 4 |
| 6 | 8 | 0.16 | 165 | 15.14 | 258 | 645 | 3.42 / 80.71 | 2 | 14 |
| Average= | 3.36 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 111.24 | 31 | 15.12 | 396 | 186 | 0.19 / 74.08 | 2 | 3 |
| 2 | 7 | 2005.96 | 38 | 14.76 | 2739 | 1536 | 1.72 / 75.61 | 2 | 4 |
| 3 | 13 | 1356.48 | 18 | 14.84 | 1981 | 529 | 2.25 / 76.14 | 2 | 7 |
| 4 | 13 | 862.88 | 18 | 14.94 | 1386 | 373 | 2.62 / 76.52 | 2 | 9 |
| 5 | 13 | 161.32 | 18 | 15.14 | 476 | 130 | 2.75 / 76.65 | 2 | 4 |
| 6 | 8 | 0.20 | 165 | 15.14 | 258 | 645 | 3.40 / 77.29 | 2 | 15 |
| Average= | 3.36 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 119.24 | 31 | 15.11 | 413 | 193 | 0.19 / 70.68 | 2 | 3 |
| 2 | 7 | 2010.20 | 38 | 14.77 | 2738 | 1537 | 1.73 / 72.21 | 2 | 5 |
| 3 | 13 | 1350.56 | 18 | 14.86 | 1985 | 531 | 2.26 / 72.75 | 2 | 5 |
| 4 | 13 | 803.28 | 18 | 14.97 | 1308 | 352 | 2.61 / 73.10 | 2 | 7 |
| 5 | 13 | 201.36 | 18 | 15.13 | 531 | 145 | 2.76 / 73.24 | 2 | 4 |
| 6 | 8 | 0.12 | 165 | 15.15 | 260 | 650 | 3.41 / 73.89 | 2 | 15 |
| Average= | 3.36 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 107.28 | 30 | 15.11 | 399 | 181 | 0.18 / 67.28 | 2 | 3 |
| 2 | 7 | 2009.12 | 38 | 14.76 | 2731 | 1532 | 1.71 / 68.81 | 2 | 3 |
| 3 | 13 | 1336.76 | 18 | 14.86 | 1961 | 525 | 2.24 / 69.34 | 2 | 7 |
| 4 | 13 | 841.88 | 18 | 14.95 | 1353 | 364 | 2.60 / 69.70 | 2 | 7 |
| 5 | 13 | 181.16 | 18 | 15.14 | 505 | 138 | 2.74 / 69.84 | 2 | 4 |
| 6 | 8 | 0.08 | 165 | 15.14 | 259 | 647 | 3.39 / 70.48 | 2 | 14 |
| Average= | 3.36 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 116.40 | 30 | 15.12 | 413 | 187 | 0.19 / 63.83 | 2 | 3 |
| 2 | 7 | 2000.32 | 38 | 14.78 | 2723 | 1529 | 1.72 / 65.35 | 2 | 7 |
| 3 | 13 | 1473.04 | 18 | 14.83 | 2119 | 566 | 2.28 / 65.92 | 2 | 7 |
| 4 | 13 | 858.76 | 18 | 14.96 | 1374 | 370 | 2.65 / 66.29 | 2 | 9 |
| 5 | 13 | 249.88 | 18 | 15.12 | 592 | 161 | 2.81 / 66.45 | 2 | 4 |
| 6 | 8 | 0.24 | 165 | 15.14 | 259 | 647 | 3.46 / 67.10 | 2 | 15 |
| Average= | 3.35 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 110.76 | 30 | 15.11 | 413 | 187 | 0.19 / 60.39 | 2 | 3 |
| 2 | 7 | 2004.20 | 38 | 14.77 | 2742 | 1539 | 1.73 / 61.92 | 2 | 6 |
| 3 | 13 | 1392.32 | 18 | 14.86 | 2024 | 541 | 2.27 / 62.47 | 2 | 6 |
| 4 | 13 | 884.12 | 18 | 14.94 | 1413 | 380 | 2.65 / 62.85 | 2 | 8 |
| 5 | 13 | 183.48 | 18 | 15.14 | 505 | 138 | 2.79 / 62.98 | 2 | 5 |
| 6 | 8 | 0.08 | 165 | 15.15 | 262 | 655 | 3.44 / 63.64 | 2 | 15 |
| Average= | 3.35 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 119.36 | 30 | 15.12 | 417 | 189 | 0.19 / 56.96 | 2 | 3 |
| 2 | 7 | 2005.08 | 38 | 14.78 | 2724 | 1530 | 1.72 / 58.49 | 2 | 5 |
| 3 | 13 | 1428.12 | 18 | 14.85 | 2065 | 552 | 2.27 / 59.04 | 2 | 6 |
| 4 | 13 | 818.16 | 18 | 14.97 | 1325 | 357 | 2.63 / 59.40 | 2 | 7 |
| 5 | 13 | 158.80 | 18 | 15.15 | 482 | 131 | 2.76 / 59.53 | 2 | 4 |
| 6 | 8 | 0.08 | 165 | 15.15 | 267 | 667 | 3.43 / 60.20 | 2 | 12 |
| Average= | 3.34 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 113.84 | 30 | 15.12 | 413 | 187 | 0.19 / 53.57 | 2 | 3 |
| 2 | 7 | 2002.92 | 39 | 14.79 | 2718 | 1568 | 1.76 / 55.13 | 2 | 3 |
| 3 | 13 | 1308.96 | 18 | 14.88 | 1920 | 514 | 2.27 / 55.65 | 2 | 5 |
| 4 | 13 | 821.24 | 18 | 14.98 | 1325 | 357 | 2.63 / 56.00 | 2 | 8 |
| 5 | 13 | 128.16 | 18 | 15.16 | 435 | 119 | 2.75 / 56.12 | 2 | 4 |
| 6 | 8 | 0.24 | 165 | 15.16 | 259 | 648 | 3.39 / 56.77 | 2 | 14 |
| Average= | 3.34 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 108.24 | 30 | 15.12 | 404 | 183 | 0.18 / 50.18 | 2 | 3 |
| 2 | 7 | 2011.00 | 38 | 14.78 | 2734 | 1536 | 1.72 / 51.72 | 2 | 5 |
| 3 | 13 | 1296.32 | 18 | 14.89 | 1903 | 510 | 2.23 / 52.23 | 2 | 6 |
| 4 | 13 | 849.16 | 18 | 14.96 | 1364 | 367 | 2.60 / 52.60 | 2 | 7 |
| 5 | 13 | 121.84 | 18 | 15.16 | 432 | 118 | 2.71 / 52.72 | 2 | 4 |
| 6 | 8 | 0.08 | 165 | 15.15 | 265 | 662 | 3.38 / 53.38 | 2 | 14 |
| Average= | 3.34 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 114.04 | 30 | 15.12 | 411 | 186 | 0.19 / 46.83 | 2 | 3 |
| 2 | 7 | 2010.52 | 38 | 14.79 | 2733 | 1536 | 1.72 / 48.37 | 2 | 3 |
| 3 | 13 | 1333.72 | 18 | 14.88 | 1952 | 523 | 2.25 / 48.89 | 2 | 5 |
| 4 | 13 | 753.44 | 18 | 14.99 | 1240 | 335 | 2.58 / 49.22 | 2 | 8 |
| 5 | 13 | 147.20 | 18 | 15.16 | 463 | 126 | 2.71 / 49.35 | 2 | 4 |
| 6 | 8 | 0.16 | 165 | 15.16 | 260 | 650 | 3.36 / 50.00 | 2 | 16 |
| Average= | 3.33 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 112.08 | 30 | 15.13 | 407 | 185 | 0.18 / 43.44 | 2 | 3 |
| 2 | 7 | 2006.36 | 38 | 14.80 | 2724 | 1532 | 1.72 / 44.97 | 2 | 5 |
| 3 | 13 | 1352.88 | 18 | 14.89 | 1970 | 528 | 2.24 / 45.50 | 2 | 5 |
| 4 | 13 | 822.60 | 18 | 14.98 | 1333 | 359 | 2.60 / 45.86 | 2 | 7 |
| 5 | 13 | 165.96 | 18 | 15.17 | 495 | 135 | 2.74 / 45.99 | 2 | 4 |
| 6 | 8 | 0.20 | 165 | 15.17 | 261 | 653 | 3.39 / 46.64 | 2 | 12 |
| Average= | 3.33 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 111.12 | 30 | 15.13 | 402 | 182 | 0.18 / 40.04 | 3 | 3 |
| 2 | 7 | 2003.20 | 38 | 14.80 | 2716 | 1527 | 1.71 / 41.56 | 2 | 6 |
| 3 | 13 | 1351.16 | 18 | 14.89 | 1970 | 528 | 2.24 / 42.09 | 2 | 7 |
| 4 | 13 | 902.76 | 18 | 14.97 | 1422 | 383 | 2.62 / 42.47 | 2 | 8 |
| 5 | 13 | 142.52 | 18 | 15.17 | 456 | 125 | 2.75 / 42.60 | 2 | 4 |
| 6 | 8 | 0.04 | 165 | 15.17 | 261 | 653 | 3.40 / 43.25 | 2 | 14 |
| Average= | 3.33 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 114.96 | 30 | 15.14 | 410 | 186 | 0.19 / 36.70 | 3 | 3 |
| 2 | 7 | 2008.12 | 38 | 14.82 | 2716 | 1530 | 1.72 / 38.23 | 2 | 5 |
| 3 | 13 | 1279.76 | 18 | 14.91 | 1891 | 508 | 2.22 / 38.73 | 2 | 5 |
| 4 | 13 | 763.08 | 18 | 15.02 | 1243 | 336 | 2.56 / 39.07 | 2 | 8 |
| 5 | 13 | 148.56 | 18 | 15.19 | 463 | 127 | 2.69 / 39.20 | 2 | 5 |
| 6 | 8 | 0.24 | 165 | 15.17 | 262 | 656 | 3.34 / 39.85 | 2 | 15 |
| Average= | 3.32 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 119.08 | 30 | 15.14 | 409 | 186 | 0.19 / 33.31 | 2 | 3 |
| 2 | 3 | 1019.36 | 1 | 15.23 | 1596 | 24 | 0.21 / 33.33 | 2 | 5 |
| 3 | 7 | 2004.12 | 38 | 14.82 | 2728 | 1536 | 1.75 / 34.87 | 2 | 6 |
| 4 | 13 | 1323.24 | 18 | 14.91 | 1947 | 523 | 2.27 / 35.39 | 2 | 6 |
| 5 | 13 | 787.88 | 18 | 15.01 | 1288 | 348 | 2.62 / 35.74 | 2 | 6 |
| 6 | 13 | 118.72 | 18 | 15.19 | 431 | 118 | 2.73 / 35.86 | 2 | 4 |
| 7 | 8 | 0.28 | 165 | 15.18 | 262 | 656 | 3.39 / 36.51 | 2 | 14 |
| Average= | 3.32 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 117.28 | 29 | 15.14 | 411 | 180 | 0.18 / 29.18 | 3 | 3 |
| 2 | 3 | 1026.12 | 1 | 15.21 | 1608 | 24 | 0.20 / 29.20 | 2 | 5 |
| 3 | 7 | 2003.68 | 74 | 14.68 | 2707 | 2941 | 3.15 / 32.14 | 2 | 6 |
| 4 | 13 | 436.64 | 18 | 15.10 | 835 | 227 | 3.37 / 32.37 | 2 | 6 |
| 5 | 13 | 41.36 | 18 | 15.21 | 323 | 88 | 3.46 / 32.46 | 2 | 5 |
| 6 | 8 | 0.08 | 165 | 15.17 | 264 | 661 | 4.12 / 33.12 | 2 | 12 |
| Average= | 3.31 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 117.48 | 31 | 15.14 | 401 | 188 | 0.19 / 25.03 | 2 | 3 |
| 2 | 3 | 954.88 | -1 | 15.59 | 0 | 0 | 0.00 / 25.03 | 2 | 3 |
| 3 | 7 | 2006.72 | 75 | 14.68 | 2725 | 3000 | 3.19 / 28.03 | 2 | 6 |
| 4 | 13 | 442.52 | 18 | 15.11 | 844 | 230 | 3.42 / 28.25 | 2 | 7 |
| 5 | 13 | 42.00 | 18 | 15.20 | 320 | 88 | 3.51 / 28.34 | 2 | 5 |
| 6 | 8 | 0.16 | 165 | 15.18 | 262 | 656 | 4.16 / 29.00 | 2 | 11 |
| Average= | 3.22 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 117.20 | 29 | 15.15 | 412 | 181 | 0.18 / 21.13 | 2 | 3 |
| 2 | 7 | 1810.68 | 74 | 14.76 | 2500 | 2731 | 2.91 / 23.86 | 2 | 7 |
| 3 | 13 | 461.52 | 18 | 15.11 | 866 | 236 | 3.15 / 24.10 | 2 | 5 |
| 4 | 13 | 43.08 | 18 | 15.21 | 324 | 89 | 3.24 / 24.19 | 2 | 5 |
| 5 | 8 | 0.12 | 165 | 15.18 | 260 | 651 | 3.89 / 24.84 | 2 | 17 |
| Average= | 3.10 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 116.92 | 28 | 15.14 | 403 | 171 | 0.17 / 17.27 | 3 | 3 |
| 2 | 3 | 1017.56 | 1 | 15.22 | 1605 | 24 | 0.20 / 17.30 | 2 | 4 |
| 3 | 7 | 1811.96 | 74 | 14.76 | 2504 | 2735 | 2.93 / 20.03 | 2 | 8 |
| 4 | 13 | 311.64 | 18 | 15.16 | 668 | 182 | 3.11 / 20.21 | 2 | 5 |
| 5 | 13 | 44.68 | 18 | 15.22 | 326 | 89 | 3.20 / 20.30 | 2 | 5 |
| 6 | 8 | 0.08 | 165 | 15.18 | 258 | 646 | 3.85 / 20.95 | 3 | 14 |
| Average= | 2.99 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 113.12 | 28 | 15.18 | 399 | 170 | 0.17 / 13.50 | 3 | 3 |
| 2 | 7 | 1773.12 | 74 | 14.78 | 2447 | 2676 | 2.85 / 16.18 | 2 | 8 |
| 3 | 13 | 333.20 | 18 | 15.15 | 695 | 190 | 3.04 / 16.36 | 2 | 5 |
| 4 | 13 | 47.80 | 18 | 15.22 | 322 | 88 | 3.12 / 16.45 | 2 | 5 |
| 5 | 8 | 0.20 | 165 | 15.18 | 259 | 649 | 3.77 / 17.10 | 2 | 13 |
| Average= | 2.85 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 105.72 | 28 | 15.18 | 350 | 149 | 0.15 / 10.28 | 2 | 3 |
| 2 | 7 | 1506.64 | 74 | 14.88 | 2109 | 2322 | 2.47 / 12.61 | 2 | 5 |
| 3 | 13 | 158.76 | 18 | 15.22 | 445 | 122 | 2.59 / 12.73 | 2 | 4 |
| 4 | 8 | 0.00 | 165 | 15.21 | 240 | 602 | 3.20 / 13.33 | 2 | 10 |
| Average= | 2.67 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 116.76 | 26 | 15.18 | 374 | 148 | 0.15 / 7.03 | 2 | 3 |
| 2 | 10 | 1037.96 | 2 | 15.17 | 1577 | 48 | 0.20 / 7.08 | 2 | 5 |
| 3 | 3 | 1022.80 | 1 | 15.21 | 1606 | 24 | 0.22 / 7.11 | 2 | 3 |
| 4 | 7 | 1506.68 | 74 | 14.89 | 2106 | 2321 | 2.54 / 9.43 | 2 | 8 |
| 5 | 13 | 220.20 | 18 | 15.20 | 524 | 143 | 2.68 / 9.57 | 2 | 5 |
| 6 | 8 | 0.04 | 165 | 15.22 | 225 | 565 | 3.25 / 10.13 | 2 | 15 |
| Average= | 2.53 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 112.88 | 33 | 15.20 | 370 | 186 | 0.19 / 3.88 | 2 | 3 |
| 2 | 3 | 820.96 | -3 | 15.61 | 0 | 0 | 0.00 / 3.88 | 2 | 3 |
| 3 | 3 | 894.96 | -2 | 15.63 | 0 | 0 | 0.00 / 3.88 | 2 | 3 |
| 4 | 7 | 1522.52 | 74 | 14.89 | 2118 | 2334 | 2.52 / 6.21 | 2 | 11 |
| 5 | 13 | 127.24 | 18 | 15.23 | 400 | 110 | 2.63 / 6.32 | 2 | 4 |
| 6 | 8 | 0.12 | 165 | 15.22 | 224 | 563 | 3.19 / 6.89 | 2 | 13 |
| Average= | 2.30 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 112.52 | 28 | 15.36 | 334 | 144 | 0.14 / 1.48 | 3 | 3 |
| 2 | 7 | 976.56 | 74 | 15.08 | 1462 | 1631 | 1.78 / 3.11 | 2 | 10 |
| 3 | 8 | 0.04 | 165 | 15.26 | 231 | 582 | 2.36 / 3.69 | 2 | 17 |
| Average= | 1.85 (KJ/cycle) |
| Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
| 1 | 2 | 160.96 | 28 | 15.54 | 399 | 174 | 0.17 / 0.17 | 3 | 3 |
| 2 | 7 | 175.88 | 75 | 15.49 | 415 | 482 | 0.66 / 0.66 | 3 | 3 |
| 3 | 8 | 0.20 | 236 | 15.44 | 187 | 681 | 1.34 / 1.34 | 3 | 245 |
| Average= | 1.34 (KJ/cycle) |