SIO Argo Site:
|
![]() |
![]() |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.04 | 29 | 15.10 | 413 | 181 | 0.18 / 79.74 | 3 | 3 |
2 | 7 | 1657.24 | 38 | 14.92 | 2348 | 1331 | 1.51 / 81.07 | 2 | 12 |
3 | 13 | 1204.48 | 18 | 14.95 | 1816 | 489 | 2.00 / 81.56 | 2 | 16 |
4 | 13 | 661.48 | 18 | 15.04 | 1138 | 308 | 2.31 / 81.86 | 2 | 18 |
5 | 13 | 217.76 | 18 | 15.15 | 566 | 154 | 2.46 / 82.02 | 2 | 19 |
6 | 13 | 120.48 | 18 | 15.17 | 441 | 120 | 2.58 / 82.14 | 2 | 19 |
7 | 13 | 92.60 | 18 | 15.16 | 397 | 108 | 2.69 / 82.25 | 2 | 20 |
8 | 8 | 0.08 | 165 | 15.15 | 262 | 655 | 3.35 / 82.90 | 3 | 21 |
Average= | 3.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.60 | 29 | 15.11 | 415 | 182 | 0.18 / 76.08 | 3 | 3 |
2 | 7 | 2008.84 | 38 | 14.78 | 2769 | 1555 | 1.74 / 77.64 | 2 | 10 |
3 | 13 | 1333.92 | 18 | 14.86 | 1966 | 526 | 2.26 / 78.16 | 2 | 15 |
4 | 13 | 801.96 | 18 | 14.96 | 1321 | 356 | 2.62 / 78.52 | 2 | 17 |
5 | 13 | 204.40 | 18 | 15.14 | 548 | 149 | 2.77 / 78.67 | 2 | 18 |
6 | 13 | 114.16 | 18 | 15.15 | 431 | 118 | 2.89 / 78.79 | 2 | 17 |
7 | 13 | 89.44 | 18 | 15.14 | 395 | 108 | 2.99 / 78.89 | 2 | 18 |
8 | 8 | 0.24 | 165 | 15.13 | 265 | 662 | 3.65 / 79.56 | 3 | 21 |
Average= | 3.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.28 | 29 | 15.12 | 421 | 185 | 0.18 / 72.40 | 3 | 3 |
2 | 7 | 2001.16 | 38 | 14.77 | 2762 | 1550 | 1.73 / 73.95 | 2 | 11 |
3 | 13 | 1335.96 | 18 | 14.85 | 1980 | 529 | 2.26 / 74.48 | 2 | 14 |
4 | 13 | 850.04 | 18 | 14.96 | 1378 | 371 | 2.64 / 74.85 | 2 | 19 |
5 | 13 | 234.16 | 18 | 15.12 | 587 | 160 | 2.79 / 75.01 | 2 | 18 |
6 | 13 | 119.48 | 18 | 15.15 | 438 | 119 | 2.91 / 75.13 | 2 | 18 |
7 | 13 | 92.36 | 18 | 15.15 | 398 | 109 | 3.02 / 75.24 | 2 | 19 |
8 | 8 | 0.08 | 165 | 15.13 | 265 | 662 | 3.68 / 75.90 | 3 | 21 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.40 | 29 | 15.12 | 417 | 183 | 0.18 / 68.69 | 3 | 3 |
2 | 7 | 2006.60 | 39 | 14.79 | 2768 | 1597 | 1.78 / 70.29 | 2 | 12 |
3 | 13 | 1331.52 | 18 | 14.86 | 1981 | 530 | 2.31 / 70.82 | 2 | 15 |
4 | 13 | 798.24 | 18 | 14.97 | 1318 | 355 | 2.66 / 71.18 | 2 | 19 |
5 | 13 | 203.56 | 18 | 15.14 | 550 | 150 | 2.81 / 71.33 | 2 | 17 |
6 | 13 | 119.24 | 18 | 15.16 | 440 | 120 | 2.93 / 71.45 | 2 | 18 |
7 | 13 | 98.40 | 18 | 15.15 | 407 | 111 | 3.05 / 71.56 | 2 | 18 |
8 | 8 | 0.12 | 165 | 15.14 | 264 | 659 | 3.70 / 72.22 | 3 | 21 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.20 | 29 | 15.12 | 411 | 180 | 0.18 / 65.03 | 3 | 3 |
2 | 7 | 2012.28 | 38 | 14.79 | 2783 | 1564 | 1.74 / 66.60 | 2 | 11 |
3 | 13 | 1311.24 | 18 | 14.87 | 1960 | 525 | 2.27 / 67.12 | 2 | 18 |
4 | 13 | 784.24 | 18 | 15.00 | 1296 | 350 | 2.62 / 67.47 | 2 | 20 |
5 | 13 | 188.92 | 18 | 15.16 | 534 | 146 | 2.76 / 67.62 | 2 | 18 |
6 | 13 | 117.12 | 18 | 15.18 | 437 | 119 | 2.88 / 67.74 | 2 | 17 |
7 | 13 | 100.60 | 18 | 15.16 | 410 | 112 | 3.00 / 67.85 | 2 | 18 |
8 | 8 | 0.12 | 165 | 15.14 | 265 | 662 | 3.66 / 68.51 | 3 | 22 |
Average= | 3.61 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.84 | 29 | 15.13 | 413 | 181 | 0.18 / 61.36 | 3 | 3 |
2 | 7 | 2008.08 | 38 | 14.80 | 2759 | 1552 | 1.73 / 62.91 | 2 | 10 |
3 | 13 | 1358.20 | 18 | 14.87 | 1999 | 535 | 2.27 / 63.45 | 2 | 15 |
4 | 13 | 809.12 | 18 | 14.98 | 1334 | 360 | 2.63 / 63.81 | 2 | 17 |
5 | 13 | 247.40 | 18 | 15.14 | 607 | 165 | 2.79 / 63.97 | 2 | 17 |
6 | 13 | 116.64 | 18 | 15.17 | 437 | 119 | 2.91 / 64.09 | 2 | 18 |
7 | 13 | 91.64 | 18 | 15.16 | 399 | 109 | 3.02 / 64.20 | 2 | 18 |
8 | 8 | 0.16 | 165 | 15.15 | 261 | 652 | 3.67 / 64.85 | 3 | 24 |
Average= | 3.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.48 | 29 | 15.12 | 408 | 179 | 0.18 / 57.68 | 3 | 3 |
2 | 7 | 2003.96 | 39 | 14.79 | 2782 | 1605 | 1.78 / 59.28 | 2 | 11 |
3 | 13 | 1358.80 | 18 | 14.87 | 2010 | 538 | 2.32 / 59.82 | 2 | 14 |
4 | 13 | 773.36 | 18 | 15.00 | 1283 | 346 | 2.67 / 60.16 | 2 | 20 |
5 | 13 | 185.60 | 18 | 15.17 | 523 | 143 | 2.81 / 60.31 | 2 | 18 |
6 | 13 | 110.32 | 18 | 15.17 | 425 | 116 | 2.93 / 60.42 | 2 | 18 |
7 | 13 | 85.28 | 18 | 15.18 | 387 | 106 | 3.03 / 60.53 | 2 | 18 |
8 | 8 | 0.16 | 165 | 15.16 | 260 | 650 | 3.68 / 61.18 | 3 | 22 |
Average= | 3.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.60 | 29 | 15.13 | 415 | 182 | 0.18 / 53.99 | 3 | 3 |
2 | 7 | 2004.72 | 38 | 14.82 | 2784 | 1568 | 1.75 / 55.55 | 2 | 10 |
3 | 13 | 1286.16 | 18 | 14.89 | 1935 | 519 | 2.27 / 56.07 | 2 | 14 |
4 | 13 | 721.20 | 18 | 15.02 | 1219 | 330 | 2.60 / 56.40 | 2 | 18 |
5 | 13 | 175.28 | 18 | 15.17 | 510 | 139 | 2.74 / 56.54 | 2 | 18 |
6 | 13 | 92.92 | 18 | 15.18 | 403 | 110 | 2.85 / 56.65 | 2 | 18 |
7 | 13 | 74.04 | 18 | 15.18 | 371 | 101 | 2.95 / 56.75 | 2 | 18 |
8 | 13 | 17.08 | 18 | 15.19 | 291 | 80 | 3.03 / 56.83 | 3 | 16 |
9 | 8 | 0.08 | 165 | 15.15 | 266 | 665 | 3.69 / 57.50 | 3 | 24 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.24 | 29 | 15.14 | 417 | 183 | 0.18 / 50.39 | 3 | 3 |
2 | 7 | 2003.20 | 38 | 14.80 | 2760 | 1552 | 1.74 / 51.94 | 2 | 10 |
3 | 13 | 1315.72 | 18 | 14.89 | 1943 | 521 | 2.26 / 52.46 | 2 | 14 |
4 | 13 | 711.28 | 18 | 15.02 | 1205 | 326 | 2.58 / 52.78 | 2 | 18 |
5 | 13 | 182.48 | 18 | 15.17 | 525 | 143 | 2.73 / 52.93 | 2 | 18 |
6 | 13 | 97.00 | 18 | 15.18 | 410 | 112 | 2.84 / 53.04 | 2 | 18 |
7 | 13 | 75.72 | 18 | 15.17 | 377 | 103 | 2.94 / 53.14 | 2 | 18 |
8 | 8 | 0.00 | 165 | 15.16 | 264 | 660 | 3.60 / 53.80 | 3 | 21 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.84 | 29 | 15.15 | 421 | 185 | 0.18 / 46.71 | 3 | 3 |
2 | 7 | 2003.92 | 39 | 14.80 | 2774 | 1601 | 1.79 / 48.31 | 2 | 11 |
3 | 13 | 1349.72 | 18 | 14.89 | 1996 | 535 | 2.32 / 48.85 | 2 | 15 |
4 | 13 | 727.36 | 18 | 15.02 | 1230 | 333 | 2.65 / 49.18 | 2 | 18 |
5 | 13 | 186.16 | 18 | 15.18 | 529 | 145 | 2.80 / 49.32 | 2 | 17 |
6 | 13 | 112.36 | 18 | 15.18 | 430 | 117 | 2.92 / 49.44 | 2 | 18 |
7 | 13 | 92.68 | 18 | 15.18 | 399 | 109 | 3.02 / 49.55 | 2 | 17 |
8 | 8 | 0.12 | 165 | 15.17 | 261 | 653 | 3.68 / 50.20 | 3 | 22 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.40 | 29 | 15.15 | 415 | 182 | 0.18 / 43.09 | 3 | 3 |
2 | 7 | 2008.52 | 38 | 14.82 | 2763 | 1556 | 1.74 / 44.65 | 2 | 9 |
3 | 13 | 1313.80 | 18 | 14.90 | 1943 | 521 | 2.26 / 45.17 | 2 | 15 |
4 | 13 | 696.20 | 18 | 15.03 | 1188 | 321 | 2.58 / 45.49 | 2 | 18 |
5 | 13 | 208.60 | 18 | 15.17 | 558 | 152 | 2.73 / 45.64 | 2 | 18 |
6 | 13 | 105.20 | 18 | 15.19 | 419 | 115 | 2.85 / 45.76 | 2 | 17 |
7 | 13 | 85.12 | 18 | 15.17 | 386 | 105 | 2.95 / 45.86 | 3 | 17 |
8 | 8 | 0.16 | 165 | 15.17 | 264 | 661 | 3.61 / 46.52 | 3 | 22 |
Average= | 3.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.20 | 29 | 15.16 | 414 | 182 | 0.18 / 39.44 | 3 | 3 |
2 | 7 | 2013.04 | 38 | 14.80 | 2782 | 1565 | 1.75 / 41.01 | 2 | 11 |
3 | 13 | 1356.16 | 18 | 14.90 | 2005 | 538 | 2.28 / 41.55 | 2 | 15 |
4 | 13 | 736.52 | 18 | 15.03 | 1234 | 334 | 2.62 / 41.88 | 2 | 18 |
5 | 13 | 200.28 | 18 | 15.18 | 547 | 149 | 2.77 / 42.03 | 2 | 18 |
6 | 13 | 103.84 | 18 | 15.20 | 416 | 114 | 2.88 / 42.14 | 2 | 16 |
7 | 13 | 81.08 | 18 | 15.19 | 379 | 104 | 2.99 / 42.25 | 3 | 17 |
8 | 8 | 0.08 | 165 | 15.17 | 265 | 663 | 3.65 / 42.91 | 3 | 22 |
Average= | 3.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.84 | 29 | 15.16 | 408 | 179 | 0.18 / 35.81 | 3 | 3 |
2 | 7 | 2004.76 | 38 | 14.82 | 2767 | 1558 | 1.74 / 37.36 | 2 | 10 |
3 | 13 | 1340.88 | 18 | 14.90 | 1983 | 532 | 2.27 / 37.90 | 2 | 15 |
4 | 13 | 758.20 | 18 | 15.03 | 1259 | 341 | 2.61 / 38.24 | 2 | 18 |
5 | 13 | 215.60 | 18 | 15.18 | 559 | 153 | 2.76 / 38.39 | 2 | 18 |
6 | 13 | 98.28 | 18 | 15.22 | 406 | 111 | 2.87 / 38.50 | 2 | 17 |
7 | 13 | 84.80 | 18 | 15.21 | 384 | 105 | 2.98 / 38.61 | 3 | 17 |
8 | 8 | 0.12 | 165 | 15.19 | 262 | 657 | 3.64 / 39.26 | 3 | 21 |
Average= | 3.57 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.12 | 28 | 15.18 | 404 | 172 | 0.17 / 31.41 | 3 | 3 |
2 | 3 | 1021.48 | 1 | 15.25 | 1637 | 25 | 0.20 / 31.44 | 2 | 5 |
3 | 7 | 2012.16 | 74 | 14.70 | 2759 | 3001 | 3.20 / 34.44 | 2 | 16 |
4 | 13 | 436.12 | 18 | 15.13 | 842 | 229 | 3.43 / 34.67 | 2 | 19 |
5 | 13 | 100.16 | 18 | 15.22 | 407 | 112 | 3.54 / 34.78 | 2 | 18 |
6 | 13 | 80.84 | 18 | 15.21 | 377 | 103 | 3.64 / 34.88 | 2 | 18 |
7 | 13 | 45.96 | 18 | 15.21 | 328 | 90 | 3.73 / 34.97 | 2 | 17 |
8 | 8 | 0.12 | 165 | 15.19 | 261 | 654 | 4.39 / 35.63 | 3 | 23 |
Average= | 3.56 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.36 | 31 | 15.17 | 403 | 190 | 0.19 / 27.04 | 3 | 3 |
2 | 3 | 878.28 | -2 | 15.63 | 1 | 0 | 0.00 / 27.04 | 3 | 3 |
3 | 7 | 2003.52 | 74 | 14.72 | 2754 | 3000 | 3.19 / 30.04 | 2 | 15 |
4 | 13 | 479.72 | 18 | 15.13 | 901 | 245 | 3.43 / 30.29 | 2 | 18 |
5 | 13 | 96.00 | 18 | 15.23 | 399 | 109 | 3.54 / 30.40 | 2 | 17 |
6 | 13 | 72.92 | 18 | 15.23 | 366 | 100 | 3.64 / 30.50 | 2 | 18 |
7 | 13 | 39.28 | 18 | 15.23 | 318 | 87 | 3.73 / 30.59 | 3 | 18 |
8 | 8 | -0.04 | 165 | 15.20 | 261 | 655 | 4.39 / 31.24 | 3 | 24 |
Average= | 3.47 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.56 | 27 | 15.16 | 405 | 166 | 0.17 / 22.99 | 3 | 3 |
2 | 7 | 1797.12 | 75 | 14.80 | 2500 | 2775 | 2.94 / 25.76 | 2 | 14 |
3 | 13 | 399.40 | 18 | 15.15 | 797 | 217 | 3.16 / 25.98 | 2 | 17 |
4 | 13 | 105.04 | 18 | 15.22 | 415 | 114 | 3.27 / 26.09 | 2 | 17 |
5 | 13 | 78.04 | 18 | 15.23 | 377 | 103 | 3.38 / 26.20 | 2 | 18 |
6 | 8 | 0.12 | 165 | 15.20 | 262 | 657 | 4.03 / 26.85 | 3 | 23 |
Average= | 3.36 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.00 | 27 | 15.17 | 410 | 168 | 0.17 / 18.86 | 3 | 3 |
2 | 3 | 1023.20 | 1 | 15.27 | 1630 | 25 | 0.19 / 18.89 | 2 | 7 |
3 | 7 | 1812.00 | 75 | 14.79 | 2506 | 2780 | 2.97 / 21.67 | 2 | 17 |
4 | 13 | 369.04 | 18 | 15.16 | 757 | 207 | 3.18 / 21.88 | 2 | 17 |
5 | 13 | 92.52 | 18 | 15.23 | 400 | 110 | 3.29 / 21.99 | 2 | 17 |
6 | 13 | 63.20 | 18 | 15.22 | 357 | 98 | 3.39 / 22.08 | 2 | 17 |
7 | 13 | 16.60 | 18 | 15.23 | 291 | 80 | 3.47 / 22.16 | 3 | 17 |
8 | 8 | 0.00 | 165 | 15.19 | 263 | 659 | 4.13 / 22.82 | 3 | 24 |
Average= | 3.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.80 | 27 | 15.19 | 402 | 165 | 0.16 / 14.82 | 3 | 3 |
2 | 7 | 1784.84 | 74 | 14.81 | 2480 | 2718 | 2.88 / 17.54 | 2 | 14 |
3 | 13 | 384.80 | 18 | 15.16 | 776 | 212 | 3.09 / 17.75 | 2 | 17 |
4 | 13 | 93.92 | 18 | 15.24 | 400 | 110 | 3.20 / 17.86 | 2 | 17 |
5 | 13 | 68.68 | 18 | 15.23 | 364 | 100 | 3.30 / 17.96 | 2 | 17 |
6 | 13 | 17.68 | 18 | 15.24 | 291 | 80 | 3.38 / 18.04 | 3 | 18 |
7 | 8 | 0.04 | 165 | 15.19 | 263 | 659 | 4.04 / 18.70 | 3 | 22 |
Average= | 3.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.32 | 27 | 15.19 | 405 | 166 | 0.17 / 11.23 | 3 | 3 |
2 | 7 | 1519.88 | 74 | 14.92 | 2175 | 2401 | 2.57 / 13.64 | 2 | 16 |
3 | 13 | 249.44 | 18 | 15.22 | 598 | 164 | 2.73 / 13.80 | 2 | 17 |
4 | 13 | 81.84 | 18 | 15.25 | 383 | 105 | 2.84 / 13.91 | 2 | 17 |
5 | 13 | 55.44 | 18 | 15.25 | 347 | 95 | 2.93 / 14.00 | 2 | 17 |
6 | 8 | 0.04 | 165 | 15.22 | 260 | 653 | 3.58 / 14.65 | 3 | 23 |
Average= | 2.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.96 | 27 | 15.19 | 395 | 162 | 0.16 / 7.66 | 3 | 3 |
2 | 3 | 970.28 | -1 | 15.62 | 0 | 0 | 0.00 / 7.66 | 3 | 3 |
3 | 3 | 1038.68 | 1 | 15.27 | 1629 | 25 | 0.19 / 7.69 | 2 | 9 |
4 | 7 | 1508.92 | 74 | 14.92 | 2161 | 2386 | 2.57 / 10.07 | 2 | 15 |
5 | 13 | 189.64 | 18 | 15.23 | 519 | 142 | 2.72 / 10.22 | 2 | 17 |
6 | 13 | 88.12 | 18 | 15.26 | 388 | 107 | 2.82 / 10.32 | 2 | 17 |
7 | 13 | 58.68 | 18 | 15.24 | 345 | 95 | 2.92 / 10.42 | 2 | 17 |
8 | 8 | 0.08 | 165 | 15.22 | 259 | 650 | 3.57 / 11.07 | 3 | 22 |
Average= | 2.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.00 | 33 | 15.22 | 385 | 193 | 0.19 / 4.14 | 3 | 3 |
2 | 3 | 737.24 | -5 | 15.63 | 1 | 0 | 0.00 / 4.14 | 3 | 3 |
3 | 7 | 1510.00 | 74 | 14.92 | 2156 | 2380 | 2.57 / 6.52 | 2 | 16 |
4 | 13 | 245.56 | 18 | 15.21 | 583 | 160 | 2.73 / 6.68 | 2 | 16 |
5 | 13 | 103.72 | 18 | 15.24 | 395 | 108 | 2.84 / 6.79 | 2 | 16 |
6 | 13 | 66.08 | 18 | 15.24 | 341 | 94 | 2.94 / 6.88 | 3 | 16 |
7 | 8 | 0.12 | 165 | 15.21 | 248 | 622 | 3.56 / 7.50 | 3 | 22 |
Average= | 2.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.36 | 28 | 15.42 | 344 | 149 | 0.15 / 1.51 | 3 | 3 |
2 | 3 | 897.92 | -2 | 15.64 | 0 | 0 | 0.00 / 1.51 | 3 | 3 |
3 | 3 | 1023.76 | 1 | 15.33 | 1588 | 24 | 0.17 / 1.54 | 2 | 8 |
4 | 7 | 997.36 | 74 | 15.12 | 1512 | 1692 | 1.86 / 3.23 | 2 | 17 |
5 | 13 | 63.36 | 18 | 15.30 | 338 | 93 | 1.96 / 3.32 | 2 | 16 |
6 | 8 | -0.04 | 165 | 15.27 | 247 | 622 | 2.58 / 3.94 | 3 | 20 |
Average= | 1.97 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 84.96 | 28 | 15.62 | 331 | 145 | 0.14 / 0.14 | 3 | 3 |
2 | 7 | 100.96 | 75 | 15.55 | 344 | 401 | 0.55 / 0.55 | 3 | 6 |
3 | 13 | 51.92 | 18 | 15.54 | 271 | 76 | 0.62 / 0.62 | 3 | 6 |
4 | 8 | 0.24 | 234 | 15.48 | 205 | 743 | 1.36 / 1.36 | 3 | 127 |
Average= | 1.36 (KJ/cycle) |